Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 120
Filtrar
1.
J Cardiothorac Surg ; 19(1): 403, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38943166

RESUMO

BACKGROUND: There is limited data on the 2-year outcomes of transapical transcatheter edge-to-edge repair (TA-TEER) using the ValveClamp in patients with severe primary mitral regurgitation (MR) and its impact on myocardial deformation. METHODS: From July 2018 to March 2021, 53 patients with symptomatic severe primary MR underwent TA-TEER were enrolled. The endpoint was the composite of all-cause mortality, recurrent 3 + or 4 + MR, or need for mitral surgery. RESULTS: Among the 53 patients who had successfully ValveClamp implantation, 8(15.1%) reached the composite endpoint. Significant improvement in left ventricular (LV) end-diastolic volume, pulmonary artery systolic pressure, NYHA functional class, and MR severity were observed (P < 0.05 for all). Univariate Cox's regression analysis revealed that LV end-diastolic volume index, LV end-systolic volume index, left atrial volume index, and pulmonary artery systolic pressure were associated with adverse events (P < 0.05 for all). On multivariate Cox regression analysis, left atrial volume index was independently associated with the endpoint (hazard ratio, 1.049; 95% CI, 1.009-1.091; P < 0.001) after adjustment for above echocardiographic parameters. LV global longitudinal strain and apical longitudinal strain in global and regional segments decreased at 30 days, but showed a recovery at 2 years with no significant difference compared to the baseline. CONCLUSION: TA-TEER using the ValveClamp presented favorable safety and efficacy at 2-year. Myocardial deformation impairment was observed at 30 days post-procedure, but did not persist at 2 years.


Assuntos
Insuficiência da Valva Mitral , Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Masculino , Feminino , Idoso , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Pessoa de Meia-Idade , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Ecocardiografia , Estudos Retrospectivos , Cateterismo Cardíaco/métodos
2.
J Invasive Cardiol ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38848129

RESUMO

A 76-year-old man diagnosed with severe pure native aortic regurgitation (PNAR) underwent transcatheter aortic valve replacement (TAVR) due to high surgical risk. The computed tomography angiography showed no calcification and no stenosis of the aortic valve, with an annulus perimeter of 81.1 mm and sinus diameters of 35 to 38 mm.

3.
Heliyon ; 10(11): e32105, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38882380

RESUMO

Background: Patent foramen ovale (PFO) is associated with migraine; however, the mechanism of PFO-associated migraine is not well known; additionally, percutaneous closure is controversial. This study aimed to investigate in situ thrombi within the PFO and explore the possible predictors of the effectiveness of PFO closure in migraineurs. Methods: This prospective cohort study included 48 asymptomatic patients and 92 migraineurs with PFO. Optical coherence tomography (OCT) was used to evaluate the PFO microstructure. Only migraineurs underwent percutaneous closure. Migraineurs were divided into two cohorts based on the presence of a thrombus within the PFO. The symptoms were assessed at the 12-month follow-up visit. Predictors were evaluated employing multivariate logistic regression and receiver operating characteristic curve analyses. Results: In situ thrombi within PFO were identified in 69 migraineurs and in two asymptomatic patients (76.7 % vs. 4.3 %; P < 0.001). Additionally, endocardial irregularity, discontinuity, low signal, and spasm were found in 59 (65.6 %), 15 (16.7 %), 13 (14.4 %), and six (6.7 %) patients, respectively, in the migraine group. In situ thrombus was associated with migraine risk (OR 49.03; 95%CI 8.52-282.18; P < 0.001). At the 12-month follow-up of the migraineur cohort, the primary endpoint, a 50 % reduction in migraine frequency after closure (with or without thrombus in PFO) was met (85.3 % vs. 25.0 %; P < 0.001). In situ thrombus was associated with migraine relief (OR 6.75; 95%CI 1.28-35.56; P = 0.024). Conclusions: In situ thrombus and abnormal endocardium within PFOs were common in migraineurs, and in situ thrombus was a risk factor for migraine. Percutaneous closure was more effective in migraineurs with thrombi within the PFO. OCT imaging improved the understanding of pathogenic PFOs and may be helpful in selecting suitable migraineurs for PFO closure.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38841867

RESUMO

OBJECTIVES: The clinical efficacy and safety of a novel left atrial appendage (LAA) occluder of the SeaLA closure system in patients with nonvalvular atrial fibrillation (NVAF) were reported. BACKGROUND: Patients with NVAF are at a higher risk of stroke compared to healthy individuals. Left atrial appendage closure (LAAC) has emerged as a prominent strategy for reducing the risk of thrombosis in individuals with NVAF. METHODS: A prospective, multicenter study was conducted in NVAF patients with a high risk of stroke. RESULTS: The LAAC was successfully performed in 163 patients. The mean age was 66.93 ± 7.92 years, with a mean preoperative CHA2DS2-VASc score of 4.17 ± 1.48. One patient with residual flow >3 mm was observed at the 6-month follow-up, confirmed by TEE. During the follow-up, 2 severe pericardiac effusions were noted, and 2 ischemic strokes were observed. Four device-related thromboses were resolved after anticoagulation treatment. There was no device embolism. CONCLUSIONS: The LAAC with the SeaLA device demonstrates encouraging feasibility, safety, and efficacy outcomes.

5.
BMC Cardiovasc Disord ; 24(1): 293, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844866

RESUMO

Patients with previous interatrial shunt device (IASD) implantation may face greater challenges during future left atrial interventional procedures. Herein, we report the first case of left atrial appendage closure (LAAC) in a patient with previous IASD implantation. The patient successfully underwent LAAC using the LAmbre device without complications.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Humanos , Apêndice Atrial/fisiopatologia , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/instrumentação , Masculino , Feminino , Ecocardiografia Transesofagiana , Idoso , Função do Átrio Esquerdo , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/terapia , Forame Oval Patente/complicações , Forame Oval Patente/fisiopatologia , Forame Oval Patente/cirurgia , Oclusão do Apêndice Atrial Esquerdo
7.
Catheter Cardiovasc Interv ; 103(7): 1093-1100, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38690931

RESUMO

BACKGROUND: As compared to treatment of aortic stenosis (AS), transcatheter aortic valve replacement (TAVR) using the commercially available valves to treat pure aortic regurgitation (PAR) has a lower device success rate and higher complication rates. AIMS: The study compared the acute results between TAVR using a novel noncoronary sinus pivot implantation (NCPI) method and that using the conventional method, aiming to explore a more optimized and effective operation method for TAVR in PAR. METHODS: PAR patients who underwent TAVR with self-expanding valves in our center from September 2021 to September 2023 were enrolled were divided into the NCPI (group A, N = 16) and conventional method (group B, N = 39) groups. We analyzed the pre-operative evaluation parameters and procedural and postoperative data of the two subgroups. RESULTS: The total patients' mean age was 71.2 ± 8.7 years and most were male (61.8%), with a mean Society of Thoracic Surgeons score of 3.4 ± 1.9%. The device success rate of groups A and B was 100% and 71.8%, respectively. In group B, 48.7% had major adverse cardiac events (MACE); 46.2% patients had permanent pacemaker implantation or valve in valve implantation. None had MACE in group A. The noncoronary sinus implantation depth in NCPI was -1.1 + 1.0 and 4.2 + 3.7 mm in groups A and B (p < 0.001), respectively. CONCLUSIONS: TAVR with a self-expanding valve using the NCPI method had a higher procedure success rate and dramatically low complications than that using the conventional method in PAR patients.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Recuperação de Função Fisiológica , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Idoso , Resultado do Tratamento , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Tempo , Fatores de Risco , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Hemodinâmica
8.
Int J Cardiol ; 409: 132201, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38782071

RESUMO

BACKGROUND: To date, whether ascending aorta dilation (AAD) should be considered a contraindication for transcatheter aortic valve replacement (TAVR) remains a topic of debate.. OBJECTIVE: The study investigated the clinical outcome of TAVR in patients with bicuspid aortic valve stenosis (BAV-AS) complicated by AAD. METHODS: We included patients with BAV-AS who underwent TAVR between 2012 and 2019. We collected patient perioperative clinical data., tracked clinical outcomes for over four years post-TAVR, and obtained echocardiography images one year postoperatively. The Kaplan-Meier method was employed for analyzing both unadjusted and adjusted survival data, which was compared using the log-rank test. COX regression and nomograms were used to assess the impact of AAD on post-TAVR clinical outcomes in patients with aortic stenosis (AS), with all-cause mortality as the primary clinical endpoint. RESULTS: A total of 111 BAV patients were included in this study. Long-term follow-up showed an increased mortality risk in patients with BAV-AAD (adjusted Kaplan-Meier analysis: P = .02/0.001). Cox correlation analysis indicated that age (OR = 1.137; P = .034), AAD (OR = 3.51; P = .038), and postoperative left ventricular pressure (LVSP) (OR: 0.959; P = .044) were predictive factors for mortality more than four years after TAVR in patients with BAV. The area under the curve of the Nomogram predicting long-term survival for the training set of patients based on the above metrics was 0.845 (95% CI: 0.696-0.994). Short-term cardiac ultrasound follow-up showed a more rapid rate of AA expansion (0.29 [0-0.34] vs. -1 [-3.3-1] mm/month, P = .001) and a smaller proportion of AA diameter reduction (7.1% vs. 53.7%, P = .001) in patients who died. CONCLUSIONS: Patients with BAV-AAD-AS treated with TAVR have an increased risk of long-term mortality, and clinical prediction models, including AAD age and postoperative LVSP, may predict long-term patient survival. CONDENSED ABSTRACT: The study investigated the clinical outcome of transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (BAV-AS) complicated by ascending aorta dilation (AAD). Patients with BAV-AAD-AS treated with TAVR have an increased risk of long-term mortality. AAD, age and postoperative LVSP, may predict long-term patient survival. Short-term cardiac ultrasound follow-up showed a more rapid rate of AA expansion and a smaller proportion of AA diameter reduction in patients who died. A high postoperative AAD expansion rate may indicate an adverse clinical outcome. Surgery regimens for tolerable BAV-AADs and can be considered as a treatment option.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Idoso , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/complicações , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Resultado do Tratamento , Seguimentos , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Fatores de Tempo , Pessoa de Meia-Idade
9.
Artigo em Inglês | MEDLINE | ID: mdl-38753103

RESUMO

Functional tricuspid regurgitation (FTR) is the most common TR, although experimental models to effectively study it are scarce; therefore, this study aimed to establish a robust experimental swine model. A swine FTR model was developed using radiofrequency ablation, atrial septostomy, and right atrial volume overload. The baseline and follow-up echocardiography was performed to evaluate the progression FTR and changes in the heart. Autopsy was employed to verify the anatomy of tricuspid valve. One-month post intervention, among the subjects, one (8.3%) exhibited severe FTR, eight (66.7%) exhibited moderate TR, and three (25%) exhibited mild FTR. Each pig developed an atrial septal defect (diameter, 1.5 ± 0.5 cm). The tricuspid annular diameter significantly increased with enlargement of right heart (P < 0.05). No significant difference was found on left heart size and mitral regurgitation. We successfully developed a novel swine FTR model, providing a reliable and effective platform for further research on FTR.

10.
Cardiology ; : 1-8, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38626740

RESUMO

INTRODUCTION: Atrial septal defect (ASD) is one of the most common congenital heart malformations. Although not recommended, a significant proportion of patients with aortic root defects receive ASD closure, some of whom have improved right ventricular function. The study aimed to investigate the safety of interventional therapy in ASD patients with complete aortic rim deficiency and explore the predictors of right atrial (RA) non-reverse remodeling. METHODS: 1,011 patients with ASD who underwent transcatheter closure in the Department of Cardiology, Zhongshan Hospital, affiliated to Fudan University from June 2017 to June 2023 were enrolled in the study. They were divided into a complete aortic rim deficiency group and without absent aortic rim group. Furthermore, patients who had an enlarged RA in the absent aortic rim group were divided into two subgroups according to whether their RA remodeling was reversed post-procedure. Multivariate logistic regression was used to determine the predictors of RA reverse remodeling. RESULTS: During the 1-year follow-up, no major operative complications occurred in all patients with the absence of an aortic rim and a normal edge. After the operation, the right heart remodeling was significantly reversed, multivariate logistic regression analysis was performed, and it was found that no coronary heart disease before an operation, lower plasma creatinine level, and larger RA and RV dimensions were the predictive factors for the reverse of RA remodeling after treatment. CONCLUSION: Transcatheter closure of ASD with complete aortic rim deficiency is safe and feasible. For patients without coronary heart disease, the lower the creatinine value and the lower the tricuspid regurgitation before an operation, the more improvement of RA remodeling after the operation.

11.
BMJ Open ; 14(3): e080042, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38453208

RESUMO

INTRODUCTION: Transcatheter aortic valve replacement (TAVR) is a standard treatment for aortic stenosis, particularly in older adults. Reduced exercise capacity and frailty significantly impact outcomes in TAVR patients, yet current management lacks strategies to address these issues. This study aims to assess the effectiveness of home-based mobile-guided exercise-based cardiac rehabilitation in TAVR patients, led by a multidisciplinary team with clear progression milestones. METHODS AND ANALYSIS: The study involves 90 patients aged 60-89 in a single centre who will be randomised to a 3-month novel multidomain exercise intervention or routine care. Outcome assessors will be blinded towards group allocation. The primary outcome is the 6-min walk distance at month 3. The secondary outcomes include the 6-min walk distance at month 6, physical function measured by total Short Physical Performance Battery score and exercise adherence measured by the Exercise Adherence Rating Scale at months 3 and 6. Additional outcome measures, including rehospitalisations, death, handgrip strength, frailty (Fried Criteria and Essential Toolset), cognitive function (Mini-Mental State Examination), quality of life (EuroQol 5-Dimension 5-Level), nutritional status (Mini-Nutritional Assessment), anxiety (General Anxiety Disorder-7), depression (Geriatric Depression Scale), sleep (Pittsburgh Sleep Quality Index), functional capacity (Duke Activity Status Index), clinical indices (body mass index, symptoms, signs, left ventricular ejection fraction (LVEF), N-Terminal Pro-Brain Natriuretic Peptide, etc) and social support (Lubben Social Network Scale-6), along with comprehensive cost analysis, enhance the study's significance. The study's findings hold crucial implications for crafting an effective exercise-focused cardiac rehabilitation strategy for TAVR patients. Community implementation not only deepens understanding but also fosters the potential integration of exercise-based cardiac rehabilitation into self-care, promising enhanced patient adherence and overall cardiovascular health management. ETHICS AND DISSEMINATION: Ethical approval was obtained from the Zhongshan Hospital, Fudan University Ethics Committee (B2022-062R). Results will be disseminated to local stakeholders and the research community through publications and conferences. TRIAL REGISTRATION NUMBER: NCT05989594.


Assuntos
Transtornos de Ansiedade , Estenose da Valva Aórtica , Reabilitação Cardíaca , Fragilidade , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Qualidade de Vida , Volume Sistólico , Força da Mão , Função Ventricular Esquerda , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto
12.
Nurs Open ; 11(3): e2122, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38424686

RESUMO

AIM: The aim was to investigate the prevalence of, and factors related to frailty, together with early clinical outcomes, in hospitalized older patients with valvular heart disease (VHD) in China. DESIGN: A prospective observational cohort study was conducted. METHODS: A validated prospective survey was conducted to assess the prevalence of frailty, factors associated with it, and early clinical outcomes in hospitalized older patients with VHD, utilizing Fried's criterion. A total of 207 consecutive participants aged 65 years and older who underwent cardiac surgery were included in the study, spanning from September 2021 to December 2021. RESULTS: Frailty was detected in 78 patients (37.7%). Patients with multimorbidity, a New York Heart Association (NYHA) class of III/IV, or masticatory dysfunction had a greater incidence of frailty (p < 0.05). Patients with a normal albumin level and a higher frequency of exercise had a lower incidence of frailty (p < 0.05). Patients with frailty had longer hospital and intensive care unit stays and greater hospitalization costs than did those without frailty (p < 0.05). The 30-day adverse event rate of the frail group was also greater (11.5% vs. 3.1%). Therefore, early screening for conditions such as multimorbidity, cardiac dysfunction, and hypoalbuminemia is urgently needed to effectively address frailty, as it has been linked to unfavourable early outcomes. Moreover, promoting exercise and improving masticatory function and nutrition are crucial for preventing and managing frailty in older patients with VHD.


Assuntos
Fragilidade , Doenças das Valvas Cardíacas , Idoso , Humanos , Fragilidade/epidemiologia , Fragilidade/complicações , Fragilidade/diagnóstico , Idoso Fragilizado , Estudos Prospectivos , Prevalência , Doenças das Valvas Cardíacas/epidemiologia , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/complicações
14.
Eur Radiol ; 2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38308681

RESUMO

OBJECTIVES: The study aimed to investigate the prognostic value of pre-transcatheter aortic valve replacement (TAVR) computed tomography angiography (CTA) in assessing physiological stenosis severity (CTA-derived fractional flow reserve (CT-FFR)) and high-risk plaque characteristics (HRPC). MATERIALS AND METHODS: Among TAVR patients who underwent pre-procedure CTA, the presence and number of HRPCs (minimum lumen area of < 4 mm2, plaque burden ≥ 70%, low-attenuating plaques, positive remodeling, napkin-ring sign, or spotty calcification) as well as CT-FFR were assessed. The risk of vessel-oriented composite outcome (VOCO, a composite of vessel-related ischemia-driven revascularization, vessel-related myocardial infarction, or cardiac death) was compared according to the number of HRPC and CT-FFR categories. RESULTS: Four hundred and twenty-seven patients (68.4% were male) with 1072 vessels were included. Their mean age was 70.6 ± 10.6 years. Vessels with low CT-FFR (≤ 0.80) (41.7% vs. 15.8%, adjusted hazard ratio (HRadj) 1.96; 95% confidence interval (CI): 1.28-2.96; p = 0.001) or lesions with ≥ 3 HRPC (38.7% vs. 16.0%, HRadj 1.81; 95%CI 1.20-2.71; p = 0.005) demonstrated higher VOCO risk. In the CT-FFR (> 0.80) group, lesions with ≥ 3 HRPC showed a significantly higher risk of VOCO than those with < 3 HRPC (34.7% vs. 13.0%; HRadj 2.04; 95%CI 1.18-3.52; p = 0.011). However, this relative increase in risk was not observed in vessels with positive CT-FFR (≤ 0.80). CONCLUSIONS: In TAVR candidates, both CT-FFR and the presence of ≥ 3 HRPC were associated with an increased risk of adverse clinical events. However, the value of HRPC differed with the CT-FFR category, with more incremental predictability among vessels with negative CT-FFR but not among vessels with positive CT-FFR. CLINICAL RELEVANCE STATEMENT: In transcatheter aortic valve replacement (TAVR) candidates, pre-TAVR CTA provided the opportunity to assess coronary physiological stenosis severity and high-risk plaque characteristics, both of which are associated with worse clinical outcomes. KEY POINTS: • The current study investigated the prognostic value of coronary physiology significance and plaque characteristics in transcatheter aortic valve replacement patients. • The combination of coronary plaque vulnerability and physiological significance showed improved accuracy in predicting clinical outcomes in transcatheter aortic valve replacement patients. • Pre-transcatheter aortic valve replacement CT can be a one-stop-shop tool for coronary assessments in clinical practice.

15.
EuroIntervention ; 20(4): e239-e249, 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38389469

RESUMO

BACKGROUND: Severe degenerative mitral regurgitation (DMR) can cause a poor prognosis if left untreated. For patients considered at prohibitive surgical risk, transcatheter edge-to-edge repair (TEER) has become an accepted alternative therapy. The DragonFly transcatheter valve repair system is an innovative evolution of the mitral TEER device family to treat DMR. AIMS: Herein we report on the DRAGONFLY-DMR trial (ClinicalTrials.gov: NCT04734756), which was a prospective, single-arm, multicentre study on the safety and effectiveness of the DragonFly system. METHODS: A total of 120 eligible patients with prohibitive surgical risk and DMR ≥3+ were screened by a central eligibility committee for enrolment. The study utilised an independent echocardiography core laboratory and clinical event committee. The primary endpoint was the clinical success rate, which measured freedom from all-cause mortality, mitral valve reintervention, and mitral regurgitation (MR) >2+ at 1-year follow-up. RESULTS: At 1 year, the trial successfully achieved its prespecified primary efficacy endpoint, with a clinical success rate of 87.5% (95% confidence interval: 80.1-92.3%). The rates of major adverse events, all-cause mortality, mitral valve reintervention, and heart failure hospitalisation were 9.0%, 5.0%, 0.8%, and 3.4%, respectively. MR ≤2+ was 90.4% at 1 month and 92.0% at 1 year. Over time, left ventricular reverse remodelling was observed (p<0.05), along with significant improvements in the patients' functional and quality-of-life outcomes, shown by an increase in the New York Heart Association Class I/II from 32.4% at baseline to 93.6% at 12 months (p<0.001) and increased Kansas City Cardiomyopathy Questionnaire (KCCQ) score of 31.1±18.2 from baseline to 12 months (p<0.001). CONCLUSIONS: The DRAGONFLY-DMR trial contributes to increasing evidence supporting the safety and efficacy of TEER therapy, specifically the DragonFly system, for treating patients with chronic symptomatic DMR 3+ to 4+ at prohibitive surgical risk.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Resultado do Tratamento
16.
Catheter Cardiovasc Interv ; 103(4): 660-669, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38419402

RESUMO

Transcatheter pulmonary valve replacement (TPVR), also known as percutaneous pulmonary valve implantation, refers to a minimally invasive technique that replaces the pulmonary valve by delivering an artificial pulmonary prosthesis through a catheter into the diseased pulmonary valve under the guidance of X-ray and/or echocardiogram while the heart is still beating not arrested. In recent years, TPVR has achieved remarkable progress in device development, evidence-based medicine proof and clinical experience. To update the knowledge of TPVR in a timely fashion, and according to the latest research and further facilitate the standardized and healthy development of TPVR in Asia, we have updated this consensus statement. After systematical review of the relevant literature with an in-depth analysis of eight main issues, we finally established eight core viewpoints, including indication recommendation, device selection, perioperative evaluation, procedure precautions, and prevention and treatment of complications.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Valva Pulmonar , Humanos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Resultado do Tratamento , Ásia , Catéteres
17.
Quant Imaging Med Surg ; 14(1): 1061-1069, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38223060

RESUMO

The prohibitive risk of isolated tricuspid valve (TV) surgery encouraged rapid development of a transcatheter solution for tricuspid regurgitation (TR). The favorable results of these devices informed recent guidelines to recommend considering transcatheter treatment of symptomatic secondary severe TR in inoperable patients. Transcatheter TV repair systems usually reduce TR through leaflet approximation and direct annuloplasty. Orthotopic transcatheter TV replacement (TTVR) devices generally rely on radial force and tricuspid leaflet engagement for implantation and stability. The LuX-Valve is a novel radial force-independent orthotopic TTVR device that is operated through the trans-atrial approach. Its radial force-independency is achieved through an interventricular septal anchor tab (septal insertion) and two leaflet graspers (leaflet engagement). Such a unique design makes the intraprocedural imaging different from that of other currently available TTVR systems. The latest generation of this device, the LuX-Valve Plus, comes with a newly designed delivery system through the transjugular approach, which makes the intraprocedural monitoring and adjustment of the device even more complex for successful implantation. However, its unique imaging needs for intra-procedural guidance and post-operative evaluation have not been described before. Therefore, we aimed to elaborate the key steps of transesophageal echocardiography (TEE) to guide this novel procedure. Herein, the primary 2-dimensional (2D) and 3-dimensional (3D) echocardiographic work planes are proposed and the critical steps are emphasized for better communication between imagers and interventionists. The suitability of 2D and 3D echocardiography to guide this procedure is also discussed to increase the flexibility of choice during the implantation.

18.
Eur J Med Res ; 29(1): 85, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38287454

RESUMO

BACKGROUND: The risk and timing of permanent pacemaker implantation (PPMI) after transcatheter aortic valve replacement (TAVR) is still hard to predict. We aimed to analyze the relationship between the compression ratio of a self-expandable valve (SEV) and the need for PPMI after TAVR. METHODS: A total of 106 patients who were implanted with the VitaFlow transcatheter aortic valve system and for whom complete imaging information was available were included in this retrospective cohort study. Eight lines perpendicular to the long axis of the SEV were drawn (the top and bottom of the SEV and the intersection of each row of wires) for measurement purposes. The compression ratio was calculated as 1 - (in vivo meridian/in vitro meridian) and compared between patients undergoing and those not undergoing PPMI after adjusting for implantation depth. Multivariable logistic regression and Cox proportional hazards models were used to assess factors associated with the risk and timing of the need for PPMI. RESULTS: Fifteen (14.2%) patients underwent PPMI after TAVR. Patients with a higher mean compression ratio (20%, odds ratio [OR] = 214.82; p < 0.001) and prior right bundle branch block (OR = 51.77; p = 0.015) had a higher risk of the need for PPMI after TAVR. These two factors were also associated with the timing of PPMI, according to the Cox proportional hazards model. CONCLUSIONS: The compression ratio of the SEV was positively associated with the risk of PPMI after TAVR, and the association was most significant in the annular and supravalvular planes. The compression ratio may also affect the time to PPMI.


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estimulação Cardíaca Artificial , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Resultado do Tratamento
19.
Catheter Cardiovasc Interv ; 103(2): 359-366, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38054354

RESUMO

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) with the self-expandable Venus P-valve system is a promising treatment for patients with pulmonary regurgitation (PR) and a native right ventricular outflow tract (RVOT). However, limited data is available regarding its midterm outcomes. This study assessed the midterm clinical and echocardiographic outcomes following Venus P-valve implantation. METHODS: From 2013 to 2018, 55 patients with moderate or severe PR after surgical RVOT repair with a transannular or RVOT patch were consecutively enrolled from six hospitals in China. Five-year clinical and echocardiographic outcomes were collected and evaluated. The primary endpoint was a freedom from all-cause mortality and reintervention. RESULTS: At 5 years, the primary endpoint was met for 96% of patients, corresponding to a freedom from all-cause mortality of 96% (95% confidence interval [CI]: 86%-99%) and freedom from reintervention of 98% (95% CI: 87%-100%). Endocarditis was reported in five patients (four patients within 1 year and one patient at 5 years) following PPVI. Transpulmonary gradient and stent orifice diameter remained stable compared to at discharge (p>0.05). No paravalvular leak was reported while only 1 patient gradually increased to moderate PR during follow-up. Significant improvement of RV diameter and LVEF (p<0.001) sustained over the 5-year follow-up, in consistent with remarked improved New York Heart Association(NYHA) functional class (p<0.001). CONCLUSION: The 5-year results of the China VenusP Study demonstrated the midterm benefits of Venus P-valve implantation in the management of patients with severe PR with an enlarged native RVOT by providing sustained symptomatic and hemodynamic improvement.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Obstrução do Fluxo Ventricular Externo , Humanos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Seguimentos , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Desenho de Prótese , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia
20.
Curr Vasc Pharmacol ; 22(1): 67-77, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38038005

RESUMO

BACKGROUND: Pulmonary arterial hypertension (PAH) still lacks effective biomarkers to assist in its diagnosis and prognosis. Galectin-3 binding protein (Gal-3BP) plays a role in immune and inflammatory diseases. OBJECTIVE: This study aimed to evaluate Gal-3BP as a prognostic and predictive factor in patients with PAH. METHODS: From January 2017 to December 2019, we enrolled 167 consecutive PAH patients and 58 healthy controls. Right heart catheterization (RHC) was used to diagnose PAH. Serum Gal-3BP levels were measured by high-sensitivity human enzyme-linked immunosorbent assay (ELISA). RESULTS: Serum Gal-3BP levels in the PAH group were significantly higher compared with the control group (4.87±2.09 vs 2.22±0.86 µg/mL, p<0.001). Gal-3BP level was correlated with several hemodynamic parameters obtained from RHC (p<0.001). Multivariate linear regression analysis showed that Gal-3BP was a risk factor for PAH (odds ratio (OR)=2.947, 95% CI: 1.821-4.767, p<0.001). The optimal cut-off value of serum Gal-3BP level for predicting PAH was 2.89 µg/mL (area under the curve (AUC)=0.860, 95 % CI: 0.811-0.910, p<0.001). Kaplan-Meier analysis showed that Gal-3BP levels above the median (4.87 µg/mL) were associated with an increased risk of death in patients with PAH (hazard ratio (HR)=8.868, 95 % CI: 3.631-21.65, p<0.0001). Cox multivariate risk regression analysis showed that Gal-3BP was a risk factor for death in PAH patients (HR=2.779, 95 % CI: 1.823-4.237, p<0.001). CONCLUSION: Serum Gal-3BP levels were increased in patients with PAH, and levels of Gal-3BP were associated with the severity of PAH. Gal-3BP might have predictive value for the diagnosis and prognosis of PAH.


Assuntos
Hipertensão Arterial Pulmonar , Humanos , Biomarcadores , Prognóstico , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...