Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Eur Heart J Case Rep ; 8(4): ytae170, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38654758

RESUMO

Background: Ventricular septal defect (VSD) is the most common type of congenital heart abnormality with perimembranous VSD (pmVSD) accounting for ∼70% of all VSD. Nowadays, transcatheter closure is the first choice for suitable pmVSD. However, there was no report about closing the large oval-shaped VSD percutaneously. Case summary: A 34-year-old male with known VSD was referred for transcatheter closure after failed attempts in other hospital. Patient had been diagnosed with VSD at a young age, but he was lost to follow-up. He presented with shortness of breath due to heart failure and pulmonary hypertension. The initial measurement of the defect was 6-7 mm by transthoracic echocardiography (TTE), transoesophageal echocardiography (TEE), and LV angiography. However, re-measurement using TEE and 3D echocardiography revealed that the VSD is oval with diameters of 18 mm × 6 mm. Initially, device No. 12/14 was used, but it was dislodged on two attempts. The operator then decided to upsize the device size to No. 16/18 that was successful. The patient's condition was good, and 6 months follow-up after the procedure showed good outcomes without any residual defect or arrhythmia. Discussion: In this study, we would like to highlight the rarity of large oval pmVSD that almost failed to be closed with the conventional measurement with echocardiography and fluoroscopy. Transoesophageal echocardiography especially 3D can be the new modality of choice that might be superior to fluoroscopy to decide the right device size in some cases such as oval-shaped pmVSD.

2.
Echocardiography ; 41(3): e15785, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38527004

RESUMO

BACKGROUND: Trans-catheter mitral valve replacement (TMVR) procedures had emerged as an alternative solution for patients who are at high risk for mitral valve surgery. Although cardiac computed tomography (CT) remains the standard method for procedural planning, there is no full agreement on the best systolic phase for quantitation of the neoLVOT. Furthermore, a new three-dimensional trans-esophageal echocardiography (3DTEE) based software was developed to serve as filter and or an alternative for patients who cannot have CT due to any contraindication. AIM: To determine the systolic phase of the cardiac cycle that shows the narrowest NeoLVOT area in order to standardize the way of using these software and then to validate the 3DTEE-based software against the CT-based one as a gold standard, in mitral valve annulus (MA) and NeoLVOT assessment. METHODS: A single center, observational, retrospective study. Initially, a sample of 20 patients (age 62 ± 4 years, 70% men) had CT-based analysis at mid-diastole (80%), early-systole (10%), mid-systole (20%), late-systole (30%-40%), in order to detect the best systolic phase at which the neoLVOT area is the narrowest after TMVR. Then, the end systolic phase was standardized for the analysis of 49 patients (age 57 ± 6 years, 60% men), using both the commercially available CT-based software and the newly available 3DTEE-based software (3mensio Structural Heart, Pie Medical Imaging, The Netherlands). The 3DTEE derived parameters were compared with the gold standard CT-based measurements. RESULTS: The neoLVOT area was significantly narrower at end-systole (224 ± 62 mm2), compared to early-systole (299 ± 70 mm2) and mid-systole (261 ± 75 mm2), (p = .005). Excellent correlation was found between 3DTEE and CT measurements for MA AP diameter (r = .96), IC diameter (r = .92), MA area (r = .96), MA perimeter (r = .94) and NeoLVOT area (r = .96), (all p-values < .0001). Virtual valve sizing was based on annulus measurement and was identical between CT and 3DTEE. Interobserver and intraobserver agreements were excellent for all the measurements with ICCs > .80. CONCLUSIONS: End-systole is the phase that shows the narrowest neoLVOT and hence should be the standard phase used during the analysis. The 3DTEE based analysis using this new software is reliable compared to the CT-based analysis and can be serve as an alternative analysis tool in patients who cannot have CT for any clinical contraindication or as a screening test and/or filter for all patients before proceeding to a detailed CT scan.


Assuntos
Ecocardiografia Tridimensional , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Catéteres , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Padrões de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos
3.
Quant Imaging Med Surg ; 14(2): 1335-1347, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38415171

RESUMO

Background: Three-dimensional (3D) transesophageal echocardiography (TEE) has been successfully used in the sizing of left atrial appendage (LAA) occlusion devices, but its use has not yet been studied in LAA clip devices. We sought to develop and validate the novel use of 3D-TEE sizing in a novel LAA clip device for atrial fibrillation (AF) patients undergoing video-assisted thoracic surgery (VATS) ablation. Methods: Consecutive patients with isolated AF undergoing LAA clipping or excision during VATS ablation were included in the study between June 2021 and September 2022 at Fuwai Hospital. The patients underwent 3D-TEE examinations preoperatively and postoperatively. The VATS length, LAA clip effective length, and LAA excision margin length were recorded. A correlation analysis, intraclass correlation coefficient (ICC) analysis, and Bland-Altman plot analysis were conducted to examine the TEE parameters, VATS length, LAA clip effective length, and LAA excision margin length. Results: In total, 26 AF patients undergoing LAA clipping and 15 undergoing LAA excision were included in the study. In the LAA clipping group, in which the Atriclip size served as the control, the 3D-TEE with volumetric measurement (the perimeter-derived maximum orifice diameter) (R=0.938; ICC =0.934; Bland-Altman plot variability, 3.85%) showed the best sizing efficacy for the LAA clip device among the 3D-TEE with multiplanar reformatting sizing (the perimeter-derived maximum orifice diameter) (R=0.808; ICC =0.772; Bland-Altman plot variability, 3.85%), VATS sizing (R=0.851; ICC =0.756; Bland-Altman plot variability, 11.54%), and VATS plus 0.5-cm sizing (R=0.851; ICC =0.775; Bland-Altman plot variability, 11.54%) measurements (all P<0.001). In addition, for the distribution of matched sizing in the LAA clip group, 3D-TEE with volumetric measurement sizing (20/26) had a higher proportion than 3D-TEE with multiplanar reformatting sizing (11/26, P=0.011), VATS sizing (9/26, P=0.002), and VATS plus 0.5-cm sizing (14/26, P=0.08). Using the LAA excision margin length as the control, the mean difference in the LAA diameter was 1.17 cm [95% confidence interval (CI): 0.71-1.62 cm , P<0.001] in the maximum orifice diameter of two-dimensional-TEE, 0.15 cm (95% CI: -0.32 to 0.61 cm , P=0.523) in the perimeter-derived 3D multiplanar reformatting (the maximum orifice diameter), and 0.03 cm (95% CI: -0.47 to 0.53, P=0.901) in the perimeter-derived 3D volumetric (3DV) measurement (the maximum orifice diameter), and the related Pearson correlation coefficients for these modalities were 0.760 (P=0.001), 0.843 (P<0.001), and 0.963 (P<0.001), respectively. Conclusions: Our study showed that 3D-TEE might be employed in the sizing of a novel LAA clip device using the VATS approach in patients with AF. The 3DV measurement (the perimeter-derived maximum orifice diameter) was superior to the VATS measurement. These findings might also apply to LAA VATS excision patients with AF.

5.
Echocardiography ; 40(10): 1112-1116, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37646446

RESUMO

Although dextrocardia is a rare congenital anomaly, it may be accompanied by numerous pathologies. Tricuspid valve prolapse is an extremely uncommon cause of primary tricuspid valve disease, as is its association with dextrocardia. In this instance, we wished to share our knowledge of tricuspid commissural prolapse together with dextrocardia, which we augmented with 3D images.


Assuntos
Dextrocardia , Doenças das Valvas Cardíacas , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Doenças das Valvas Cardíacas/complicações , Prolapso , Imageamento Tridimensional , Dextrocardia/complicações , Dextrocardia/diagnóstico por imagem
6.
J Cardiothorac Vasc Anesth ; 37(11): 2391-2396, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37419755

RESUMO

This E-Challenge highlights an incidental prebypass transesophageal echocardiographic (TEE) finding of a right atrial membrane that impacted cardiac surgical management during triple-valve surgery. Two-dimensional and advanced 3-dimensional (3D) TEE were used in real-time to assist intraoperative decision-making. The findings, clinical course, discussion of the differential diagnosis, final diagnosis, and patient management are detailed here.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Tridimensional , Humanos , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Átrios do Coração
8.
Quant Imaging Med Surg ; 13(2): 560-571, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36819254

RESUMO

Background: Accurate assessment of the aortic annulus (AA) dimension and judgment of thoracic aorta aneurysm is crucial for patients with aortic regurgitation (AR) before surgery. The aim of this study was to evaluate the accuracy and reproducibility of three-dimensional transesophageal echocardiography (3D-TEE) methods for AA measurement and explore the predictive value of the AA dimensions obtained by 3D-TEE for high-risk thoracic aorta aneurysms using the gold standard of multi-slice computed tomography (MSCT). Methods: 3D-TEE was performed on 111 patients with pure moderate-to-severe AR, and MSCT examination was conducted simultaneously. AA dimensions were obtained using reconstruction software for these two imaging techniques. Thoracic aortic diameters at standard anatomic landmarks were also measured by MSCT. All patients were divided into two groups depending on the presence of high-risk thoracic aorta aneurysms. Results: Compared to MSCT, 3D-TEE overestimated all AA parameters. However, no statistically significant differences were found in the average bias between methods (minimum diameter: 26.07±3.57 vs. 25.88±3.68 mm, P=0.52; maximum diameter: 32.30±2.68 vs. 31.78±4.06 mm, P=0.11; area: 669.76±155.19 vs. 660.05±168.28 mm2, P=0.44; perimeter: 93.52±10.42 vs. 92.26±11.71 mm, P=0.12). 3D-TEE demonstrated good correlations with MSCT measurement for AA minimum diameter, maximum diameter, area, and perimeter (r=0.63, 0.64, 0.74, 0.69, P<0.05 for all). According to the multivariate logistic regression analysis, the AA minimum diameter obtained by 3D-TEE was the best predictor for the presence of high-risk thoracic aorta aneurysms. The sensitivity and specificity for prediction were 84.6% and 63.9%, respectively, for an AA minimum diameter ≥25.74 mm (AUC: 0.759, 95% CI: 0.668-0.850). Conclusions: AA measurements obtained by the 3D-TEE method are feasible and reliable for patients with pure AR. The AA minimum diameter measured by 3D-TEE can effectively predict the presence of high-risk thoracic aorta aneurysms.

9.
J Am Soc Echocardiogr ; 36(1): 105-110, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36174809

RESUMO

Despite many recent advances in three-dimensional (3D) transesophageal echocardiography (TEE) imagining, the process of orienting 3D TEE images is nonintuitive and uses assumptions based on idealized anatomy. Correlating two-dimensional TEE cross-sectional images to 3D reconstructions remains an additional challenge. In this article, we suggest the repurposing of the stitching artifact generated in 2-beat electrocardiogram-gated 3D TEE as a means of exactly orienting 3D images within a patient's unique anatomy. We demonstrate the application of this strategy to assess a normal mitral valve to localize scallops of mitral valve prolapse and to visualize typical left atrial appendage two-dimensional cuts in a 3D space. By taking command of stitching artifacts, cardiac imagers can successfully navigate the complex structures of the heart for optimal, individualized echocardiographic views.


Assuntos
Ecocardiografia Tridimensional , Prolapso da Valva Mitral , Humanos , Ecocardiografia Transesofagiana/métodos , Artefatos , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos
10.
Ann Med Surg (Lond) ; 80: 104238, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36045821

RESUMO

Introduction: Prosthetic valve infective endocarditis (PVE) is a diagnostic challenge even in the era of multimodality cardiovascular imaging. Case presentation: The patient was a 67-year-old male with a three-year history of bioprosthetic aortic valve replacement who presented with persistent fever and negative blood cultures. The initial transthoracic echocardiography revealed a thickened aortic root. An abscess formation was visualized upon subsequent three-dimensional transesophageal echocardiography and positron emission tomography/computerized tomography (PET/CT). The patient underwent an urgent necrotic tissue debridement and a redo Bentall surgery. The real-time polymerase chain reaction of excised tissues was positive for Streptococcus. Clinical discussion: The diagnosis of PVE and its complications requires the integration of clinical, microbiological, and serial imaging data. Although advanced imaging modalities like PET/CT allow a timely diagnosis and management, their routine use in resource-limited scenarios is difficult. Conclusion: Multimodality cardiovascular imaging plays an important role in the diagnosis of PVE. Serial echocardiographic and clinical assessments are possible alternatives when the access to advanced cardiovascular imaging modalities is limited.

11.
Echocardiography ; 39(8): 1146-1148, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35819102

RESUMO

INTRODUCTION: Subaortic membrane is an uncommon cause of left ventricular outflow tract obstruction. DISCUSSION: Whereas traditionally described of as a membrane, it is in fact a discreet circumferential shelf of raised endocardium in the left ventricular outflow tract, causing a fixed outflow obstruction. The circumferential nature of subaortic membranes is poorly appreciated on 2-dimensional imaging. CONCLUSION: Using a three-dimensional imaging and recently available on-cart rendition techniques of acquired images, we were able to better visualize the true extent of a sub-aortic membrane while also gaining insight into its origin and structure.


Assuntos
Ecocardiografia Tridimensional , Obstrução do Fluxo Ventricular Externo , Aorta , Humanos
12.
Front Cardiovasc Med ; 9: 864341, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35419432

RESUMO

Transcatheter edge-to-edge repair (TEER) therapy is recommended by the American College of Cardiology/American Heart Association (ACC/AHA) guidelines for selected patients with symptomatic severe or moderate-severe mitral regurgitation (MR). Echocardiography, in particular transesophageal echocardiography (TEE), plays a critical role in procedural planning and guidance for TEER. Recent innovations and advances in TEE techniques including three-dimensional (3D) imaging, unlimited x-plane imaging, live 3D multiplanar reconstruction, as well as transillumination imaging with color Doppler and transparency rendering have further enhanced procedural imaging for TEER, especially for complex diseases including commissural defects, clefts, and multi-segment pathologies. This review discusses the technology of these advanced procedural imaging techniques and provides a "step-by-step" guide on how to apply them during the TEER procedure with a focus on their added values in treatment of complex valve lesions.

13.
Ann Transl Med ; 10(2): 84, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35282076

RESUMO

Background: Transcatheter aortic valve implantation (TAVI) is an alternative method to treat patients with severe aortic valve disease. Accurate measurement of the aortic valve annulus and selection of the appropriate artificial valve are critical to the success of TAVI. Multilayer spiral computed tomography (MSCT) is recommended as the "gold standard" for assessing the aortic valve annulus before TAVI. However, MSCT scanning may not be possible for patients with iodine allergy, renal failure, or pregnancy. The purpose of this study is to evaluate the aortic valve annulus by three-dimensional transesophageal echocardiography (3D-TEE) and compare the results with MSCT, exploring the feasibility of 3D-TEE to guide the selection of artificial valve implantation in TAVI. Methods: We retrospectively analyzed 74 patients who successfully underwent TAVI in our hospital. Before the operation, 3D-TEE and MSCT were used to measure the maximum diameter, minimum diameter, area-derived diameter, and perimeter-derived diameter of the aortic valve annulus, and the results were analyzed for consistency. To predict the valve size based on 3D-TEE and the MSCT area-derived diameter, we compared the differences between the predicted valve size and the actual implanted valve size, and analyzed the differences between 3D-TEE and MSCT for guiding the selection of the prosthetic valve size. Results: There was no significant difference between 3D-TEE and MSCT in the measurement of the maximum diameter, minimum diameter, area, and perimeter of the aortic annulus and their derived diameter (P>0.05). The intraclass correlation coefficients for the maximum diameter, minimum diameter, area-derived diameter, and perimeter-derived diameter of the aortic annulus were 0.89, 0.83, 0.84, and 0.92, respectively. There was no statistical difference in the accuracy of both methods, 3D-TEE and MSCT, in predicting different prosthetic valve sizes for TAVI (P>0.05). Conclusions: 3D-TEE and MSCT have good agreement for measuring the values of various parameters of the aortic annulus. The accuracy of both methods was similar for predicting the aortic prosthetic valve size. 3D-TEE may provide guidance for selecting the prosthetic valve size for TAVI.

14.
J Echocardiogr ; 20(3): 151-158, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35084686

RESUMO

BACKGROUND: Postprocedural mitral stenosis (MS), or increased transmitral mean pressure gradient (TMPG), is one of the limitations of transcatheter edge-to-edge mitral valve repair using MitraClip (Abbott Vascular Inc., Santa Clara, USA); however, the usefulness of three-dimensional transesophageal echocardiography (3D-TEE) for predicting postprocedural MS in functional mitral regurgitation (MR) has not been fully elucidated. METHODS: Eighty-two consecutive functional MR patients who underwent transcatheter mitral valve repair using MitraClip were retrospectively studied. Postprocedural MS was defined as TMPG ≥ 5 mmHg by echocardiography. RESULTS: Ten patients had postprocedural MS, and 3D-TEE showed that patients with postprocedural MS had smaller preprocedural mitral valve orifice area (MVOA), anteroposterior and mediolateral diameter, leaflet area, and annulus area. Receiver operating characteristic analysis showed that leaflet area (area under the curve (AUC) 0.829), annulus area (AUC 0.813), anteroposterior diameter (AUC 0.797) and mediolateral diameter (AUC 0.803) evaluated using 3D-TEE were predictors of postprocedural MS, and their predictive abilities were higher than those of preprocedural MVOA (AUC 0.756) and preprocedural TMPG (AUC 0.716). Adding leaflet area to TMPG and MVOA resulted in higher C-statistics for predicting postprocedural MS (from 0.716 to 0.845 and from 0.756 to 0.853, respectively). CONCLUSIONS: In functional MR patients treated with MitraClip, leaflet area and annulus area evaluated using 3D-TEE had high predictive values for postprocedural MS, and their predictive abilities were higher than those of preprocedural TMPG or MVOA.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
15.
J Am Soc Echocardiogr ; 35(1): 77-85, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34311062

RESUMO

BACKGROUND: Textbook depictions of the mitral valve (MV) often illustrate it as composed of a single nonscalloped anterior leaflet, with the posterior leaflet having three symmetric and evenly spaced scallops. However, common variations in this anatomy have been noted in autopsy series for decades. Improved cardiac imaging with three-dimensional transesophageal echocardiography (TEE) now affords the ability to detect variations in scallop anatomy in vivo. The aims of this study were to catalog variations in mitral anatomy and to examine for association with mitral regurgitation in patients referred for clinical three-dimensional TEE. METHODS: Three-dimensional transesophageal echocardiographic images of the MV from 107 subjects were reviewed for MV variations. Three-dimensional analysis software was used to characterize mitral leaflet anatomy and assess the relative sizes of posterior leaflet scallops. RESULTS: Variations from the classic MV configuration were seen in 58.9%. Symmetric variations in the posterior leaflet (dominant P2 scallop, accessory P2 scallop, absent P2 scallop, and dichotomous P2 scallop) were seen in 33.6% of the study group. Asymmetric variants in the posterior leaflet (fused P1 and P2, fused P2 and P3, commissural scallop, accessory scallops, dichotomous P1 or P3, and dominant P2 or P3) were seen in 24.3%. Indentations or folds in the anterior leaflet were noted in 5.6%. Leaflet variations were not associated with patient demographics, indication for TEE, mitral regurgitation, mitral annular dimensions, or Carpentier class. CONCLUSIONS: Mitral leaflet morphologic variants were well characterized using three-dimensional TEE. Variants are common and were present with a frequency consistent with autopsy series. Mitral scallop variations were not associated with mitral regurgitation.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Pectinidae , Animais , Ecocardiografia Transesofagiana , Humanos , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem
16.
Ann Transl Med ; 9(16): 1309, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34532446

RESUMO

BACKGROUND: The assessment of interatrial septum (IAS) requires a standardized, systematic approach, including two-dimensional transthoracic echocardiography (2D TTE), 2D transesophageal echocardiography (2D TEE), and three-dimensional (3D) TEE. Although 2D TEE has been widely used for the preoperative assessment of atrial septal defect (ASD), its ability to provide reliable information is often limited due to the structural characteristics of IAS. The introduction of 3D TEE provides a unique "en face" view of IAS, which allows the visualization and accurate measurements of diameters, area, and rims of ASD. Hence, appropriate ASD imaging information is particularly important in successful transcatheter closure. METHODS: In this retrospective study, 2D TTE/TEE, and 3D TEE were performed before ASD closure, with 2D minimal and maximal diameters, areas, and residual rims being recorded. Adequate 3D TEE imaging data sets were collected and then analyzed. ASD related parameters were compared using different echocardiography. Patients who underwent ASD closure completed a clinical follow-up. RESULTS: The mean defect maximal diameter and aperture area by 3D TEE was significantly larger than that of the corresponding 2D TEE (P<0.05). There was no statistical difference in the minimal and maximal diameter or area by TEE for circular-shaped ASDs. For oval ASDs, mean minimal diameter on 2D TEE was larger than that on 3D TEE. The mean maximal diameter measured using 2D TEE was smaller than the 3D TEE measurement (16.0±7.1 vs. 19.8±8.6; P<0.05). For complex-shaped defects, there were statistical differences in minimal and maximal diameter between TEEs. Furthermore, 2D and 3D TEE had a longer superior vena cava (SVC) residual rim than did 2D TTE (P<0.05). The 3D TEE residual rims of the inferior vena cava (IVC) was significantly larger than the corresponding 2D TEE. There was a very strong correlation between the residual rim measurements using 3D and 2D TEE. However, the limits of agreement between 2D and real-time 3D TEE measurements were more apparent in the IVC rim group than in the other groups. CONCLUSIONS: Our study confirms the value of 3D TEE in assessing ASD shape and size reported by previous studies, and is also the first to accurately and systematically characterize ASD residual rim in complex ASDs.

17.
Ann Transl Med ; 9(10): 876, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34164510

RESUMO

BACKGROUND: Left atrial appendage (LAA) is significantly more likely to form thrombi in patients with atrial fibrillation (AFib). Two-dimensional transesophageal echocardiography (2D TEE) is considered the gold standard for assessing and studying LAA morphology and anatomy. However, 2D TEE can only visualize one plane at any given time. Real-time three-dimensional echocardiography (RT-3D TEE) imaging can preserve spatial and temporal resolution, which is a safe, accurate, and reproducible imaging modality. There are few reports of the usage of RT-3D TEE to study LAA in AFib patients. In our research, RT-3D TEE helps to provide detailed LAA information and identifying the presence or absence of thrombi from pectinate muscles in paroxysmal and long-standing AFib patients. METHODS: LAA morphology was analyzed in detail by 2D TEE and RT-3D TEE in 320 patients with paroxysmal or long-standing AFib. The LAA flow pattern, as maximal LAA emptying flow velocity (LAAeV), was retrieved from 2D and 3D TEE imaging. LAA morphological parameters, spontaneous echo contrast (SEC), and thrombi were also detected by 2D and 3D TEE in all patients. In addition, LAA lobes and types were classified according to the morphology by 3D TEE, and the relationship between LAA types and the incidence of thrombi was evaluated. RESULTS: Long-standing AFib had greater enlargement of LAAs (orifice diameters and area), significantly more severe SEC, and a higher thrombi clot incidence rate by 3D-TEE compared with paroxysmal AFib patients (P<0.05). In addition, cauliflower morphology in long-standing AFib patients was associated with a higher LAA thrombus (OR 2.1, 95% CI: 1.1-8.5, P=0.031) and increased prevalence of SEC. Moreover, the uncertainty of thrombi detection was significantly decreased by 3D TEE compared with 2D TEE (P<0.001), and the certainty of thrombi detection by 3D TEE also decreased slightly (P=0.06). CONCLUSIONS: RT-3D TEE is a safe and real-time option for the evaluation of LAA morphology and function. Long-standing AFib has greater LAA and SEC, as well as a higher incidence of thrombi than the paroxysmal group. Cauliflower LAA type was associated with a higher prevalence of SEC and thrombi.

18.
Comput Biol Med ; 134: 104502, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34130220

RESUMO

BACKGROUND: Real-time three-dimensional transesophageal echocardiography (3D TEE) has been increasingly used in clinic for fast 3D analysis of cardiac anatomy and function. However, 3D TEE still suffers from the limited field of view (FoV). It is challenging to adopt conventional multi-view fusion methods to 3D TEE images because feature-based registration methods tend to fail in the ultrasound scenario, and conventional intensity-based methods have poor convergence properties and require an iterative coarse-to-fine strategy. METHODS: A novel multi-view registration and fusion method is proposed to enlarge the FoV of 3D TEE images efficiently. A direct method is proposed to solve the registration problem in the Lie algebra space. Fast implementation is realized by searching voxels on three orthogonal planes between two volumes. Besides, a weighted-average 3D fusion method is proposed to fuse the aligned images seamlessly. For a sequence of 3D TEE images, they are fused incrementally. RESULTS: Qualitative and quantitative results of in-vivo experiments indicate that the proposed registration algorithm outperforms a state-of-the-art PCA-based registration method in terms of accuracy and efficiency. Image registration and fusion performed on 76 in-vivo 3D TEE volumes from nine patients show apparent enlargement of FoV (enlarged around two times) in the obtained fused images. CONCLUSIONS: The proposed methods can fuse 3D TEE images efficiently and accurately so that the whole Region of Interest (ROI) can be seen in a single frame. This research shows good potential to assist clinical diagnosis, preoperative planning, and future intraoperative guidance with 3D TEE.


Assuntos
Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Algoritmos , Humanos
19.
Saudi J Biol Sci ; 28(1): 560-565, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33424339

RESUMO

The dysfunction of left atrial appendage (LAA) is prone to form thrombus when atrial fibrillation (AF) sustained more than 48 h. Traditional 2D-TEE (transesophageal echocardiography) can not accurate evaluate the function of LAA. The purpose of this study is to analyze the relationship of LAA function parameters and thrombus formation in patients with non-valvular atrial fibrillation (NVAF) by real-time three-dimensional transesophageal echocardiography (RT-3D-TEE). High risk patients can be identified according to the characteristics of ultrasonic index in patients with left atrial appendage thrombosis, which has important clinical value and significance in the risk assessment, guiding treatment and judging prognosis. We examined the relationship between the echocardiographic parameters of LAA function and the incidence of thrombus in 102 NVAF patients. They underwent RT-3D-TEE and left atrial appendage thrombus (LAAT)/severe spontaneous echocardiographic contrast (SSEC) was found in 67 patients (thrombus group) but absent in the remaining 35 patients (non-thrombus group). After measured by QLAB software, the LAA functional parameters were significantly associated with LAAT/SEC formation. Univariate analysis indicated that AF time, LAD, LVEF, LAA-OAmax, LAAVmax, LAAVI and LAAEF demonstrated a positive association (P < 0.05). However, logistic regression analysis identified that AF time (OR:1.73, P < 0.05)、LAAEF (OR:4.09, P < 0.01)and LAAVI (OR:3.28, P < 0.01) were independent predictors of LAAT/SSEC. In patients with nonvalvular atrial fibrillation, echocardiographic parameters of LAA function are significantly associated with LAAT/SSEC.

20.
Acta Chir Belg ; 121(6): 445-448, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32046603

RESUMO

INTRODUCTION: Impending paradoxical embolism (IPDE) is a rare condition where a thrombus straddles the foramen ovale with a high risk of arterial embolism. CASES REPORT: We report two cases of impending paradoxical embolism, an uncommon condition with a high mortality rate. The first in a young woman with acute right heart failure operated emergently, the second, in an old and frail lady presenting an ischemia of the left arm, treated by anticoagulants. 3 D echocardiography imaging is presented and treatment modality is discussed. CONCLUSION: Emergent treatment is mandatory for IPDE, a serious disease with a high early mortality. This paper is a reminder of how to deal with such a rare condition.


Assuntos
Ecocardiografia Tridimensional , Embolia Paradoxal , Forame Oval Patente , Embolia Pulmonar , Ecocardiografia , Ecocardiografia Transesofagiana , Embolia Paradoxal/diagnóstico por imagem , Embolia Paradoxal/etiologia , Feminino , Forame Oval Patente/diagnóstico , Forame Oval Patente/diagnóstico por imagem , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...