Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.681
Filtrar
1.
Talanta ; 279: 126653, 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39098239

RESUMO

Patulin (PAT) is a mycotoxin-produced secondary metabolite that can contaminate foods, causing toxic effects on animal and human health. Therefore, for the first time, we have constructed a "turn-on" dual-mode aptamer sensor for PAT using oleic acid-coated upconversion nanomaterials (OA-UCNPs) and G-Quadruplex-hemin DNAzyme (G4-DNAzyme) as fluorescent and colorimetry probes. The sensor employs aptamers binding to PAT as recognition elements for specific molecule detection. Mxene-Au can be used as a biological inducer to assist OA-UCNPs in controlling fluorescence intensity. In addition, colorimetric signal amplification was performed using the trivalent G4-DNAzyme to increase detection sensitivity and reduce false positives. Under optimal conditions, the dual-mode aptasensor has a detection limit of 5.3 pg mL-1 in fluorescence and 2.4 pg mL-1 in colorimetric methods, respectively, with the wider linear range and limit of detection (LOD) of the colorimetric assay. The combination aptasensor can detect PAT with high sensitivity and high specificity and has broad application prospects in the field of food safety detection.

2.
Talanta ; 279: 126655, 2024 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-39098241

RESUMO

Quarantine plant bacteria (QPB) are significant component of invasive alien species that result in substantial economic losses and serious environmental damage. Herein, a colorimetric aptasensor has been proposed based on the sandwich structure and the cascaded catalytic strategy for on-site detecting Xanthomonas hyacinthi, a type of QPB, in natural environments. The self-screened aptamer obtained through SELEX can bind to specific sites on the surface of viable organism with high affinity and specificity, which guarantees the selectivity of aptasensor. As an important part of the aptasensor, MIL-88-NH2(Fe) not only acts as a multifunctional carrier for both aptamers and glucose oxidase, but also catalyzes enzyme-like reaction because of specific surface area, amino and peroxidase-like activity. The present of Xanthomonas hyacinthi can trigger the formation of a sandwich structure and the occurrence of cascade catalytic reaction, enabling the detection with UV-Vis spectra and naked eyes. The proposed aptasensor presents a low detection limit of 2 cfu/mL and a wide linear range of 10 -107 cfu/mL. Compared to traditional detection methods for QPB, the reasonable design, high selectivity and convenience significantly improve the detection efficiency and contribute to environmental protection.

3.
J Hazard Mater ; 477: 135365, 2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39088946

RESUMO

The rapid and accurate identification of live pathogens with high proliferative ability is in great demand to mitigate foodborne infection outbreaks. Herein, we have developed an ultrasensitive image-based aptasensing array to directly detect live Salmonella typhimurium (S.T) cells. This method relies on the long-range orientation of surfactant-decorated liquid crystals (LCs) and the superiority of aptamers (aptST). The self-assembling of hydrophobic surfactant tails leads to a perpendicular/vertical ordered film at the aqueous/LC interface and signal-off response. The addition of aptST perturbed LCs' ordering into a planar/tilted state at the aqueous phase due to electrostatic interactions between the surfactant with the aptST, and a signal-on response. Following the conformational switch of aptST in the presence of live S. typhimurium, a relative reversing signal-off response was observed upon the target concentration. This aptasensor could promptly confirm the presence of S. typhimurium without intricate DNA-extraction or pre-enrichment stats over a linear range of 1-1.1 × 106 CFU/mL and a detection limit of 1.2 CFU/mL within ∼30 min. These results were successfully validated using molecular and culture-based methods in spiked-milk samples, with a 92.61-104.61 % recovery value. Meanwhile, the flexibility of this portable sensing platform allows for its development and adoption for the precise detection of various pathogens in food and the environment.

4.
J Hazard Mater ; 477: 135358, 2024 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-39088958

RESUMO

To address the potential hazards of organophosphorus pesticides (OPs) residues in tea, an electrochemiluminescence (ECL) aptasensor based on functionalized nanomaterials was constructed in this work. Firstly, gold nanoparticles (AuNPs) were attached on the surface of multi-walled carbon nanotubes (MWCNTs) by the constant potential electrodeposition to form a compound, and it was utilized to provide excellent immobilization sites for complementary DNA (cDNA). Subsequently, composite nanomaterials were synthesized by a one-pot method with aminated Luminol/silver nanoparticles@silica nanospheres (NH2-Luminol/Ag@SiO2NSs). Finally, NH2-Luminol/Ag@SiO2NSs was combined with a malathion aptamer (Apt) to obtain signal probes (SPs) for the construction of an aptasensor. The aptasensor had a wide linear range (1×10-3-1×103 ng/mL) and a low limit of detection (LOD) (0.3×10-3 ng/mL). It had the virtues of high sensitivity, wonderful stability and excellent specificity, which could be used for the detection of malathion residue in tea. The work provides a proven way for the construction of a rapid and ultrasensitive aptasensor with low-cost.

5.
Anal Chim Acta ; 1318: 342953, 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39067928

RESUMO

BACKGROUND: Developing biosensors with antifouling properties is essential for accurately detecting low-concentration biomarkers in complex biological matrix, which is imperative for effective disease diagnosis and treatment. Herein, an antifouling electrochemical aptasensor qualifying for probing targets in human serum was explored based on newly-devised peptides that could form inverted U-shaped structures with long-term stability. RESULTS: The inverted U-shaped peptides (U-Pep) with two terminals of thiol groups grafted onto the Au-modified electrode showcase superior antifouling properties in terms of high stability against enzymatic hydrolysis and long acting against biofouling in actual biofluids. The construction of the outlined antifouling electrochemical aptasensor just involved the fabrication of Au-deposited poly(3,4 ethylenedioxythiophene) (Au/PEDOT) modified electrode, followed by one-step co-incubation in the peptides and the aptamer probes with the Au/PEDOT electrode. Taking a typical biomarker of alpha-fetoprotein (AFP) for detection, this elegant antifouling aptasenor demonstrated a nice response for probing the target AFP with a low detection limit of 0.27 pg/mL and a wide linear scope of 1.0 pg/mL to 1.0 µg/mL, and furthermore qualified for assaying of AFP in human serum samples with satisfactory accuracy and feasibility. SIGNIFICANCE: This engineering strategy of U-Pep with long-lasting antifouling efficacy opens a new horizon for high-performance antifouling biosensors suitable for detection in complex bifluids, and it could spark more inspiration for a follow-up exploration of other featured antifouling biomaterials.


Assuntos
Aptâmeros de Nucleotídeos , Incrustação Biológica , Técnicas Biossensoriais , Técnicas Eletroquímicas , Ouro , Peptídeos , Humanos , Técnicas Biossensoriais/métodos , Peptídeos/química , Ouro/química , Aptâmeros de Nucleotídeos/química , Incrustação Biológica/prevenção & controle , Eletrodos , Polímeros/química , alfa-Fetoproteínas/análise , Limite de Detecção , Compostos Bicíclicos Heterocíclicos com Pontes
6.
Biomolecules ; 14(7)2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-39062534

RESUMO

Cortisol is a key stress biomarker in humans and animals, including fishes. In aquafarming, stress monitoring using cortisol quantification can help to optimize aquaculture practices for welfare and productivity enhancement. However, most current methods for cortisol detection rely on invasive tissue sampling. In this work, we developed a gold nanoparticle (AuNP)-based cortisol sensor to address the demand of detecting picomolar ranges of cortisol from complex fish tank water matrices as a non-invasive alternative for more effective stress monitoring. We first identified a DNA aptamer with effective binding to cortisol and then conjugated the thiol-labelled aptamer to AuNPs together with a blocker molecule (CALNN) to form an Au-Apt-CALNN conjugate that is stable in fish tank water. The cortisol detection principle is based on magnesium chloride (MgCl2)-induced particle aggregation, where the cortisol-bound aptamer on the AuNPs folds into a tertiary structure and provides greater protection for Au-Apt-CALNN against MgCl2-induced aggregation due to steric stabilization. At an optimum MgCl2 concentration, the differential stability of particles with and without cortisol binding offers a limit of detection (LOD) of 100 pM for cortisol within a 35 min reaction. The aptasensor has been validated on recirculating aquaculture system (RAS) fish tank water samples by the HPLC method and was able to detect changes in water cortisol induced by two different stress paradigms. This on-site deployable and non-invasive sensor offers opportunities for more efficient and real-time fish stress monitoring for the optimization of aquaculture practices.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Ouro , Hidrocortisona , Nanopartículas Metálicas , Ouro/química , Nanopartículas Metálicas/química , Hidrocortisona/análise , Hidrocortisona/metabolismo , Animais , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , Peixes , Estresse Fisiológico , Limite de Detecção
7.
Foods ; 13(14)2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-39063260

RESUMO

A novel electrochemical aptasensor was prepared for the simultaneous determination of aflatoxin B1 (AFB1) and ochratoxin A (OTA). Composites of Au nanoparticles and polyethyleneimine-reduced graphene oxide (AuNPs/PEI-RGO) with good electrical conductivity and high specific surface area were employed as the supporting substrate, demonstrating the ability to provide more binding sites for aptamers and accelerate the electron transfer. Aptamers were immobilized on a AuNPs/PEI-RGO surface to specifically recognize AFB1 and OTA. A metal-organic framework of UiO-66-NH2 served as the signal carrier to load metal ions of Cu2+ and Pb2+, which facilitated the generation of independent current peaks and effectively improved the electrochemical signals. The prepared aptasensor exhibited sensitive current responses for AFB1 and OTA with a linear range of 0.01 to 1000 ng/mL, with detection limits of 6.2 ng/L for AFB1 and 3.7 ng/L for OTA, respectively. The aptasensor was applied to detect AFB1 and OTA in cereal samples, achieving results comparable with HPLC-MS, with recovery results from 92.5% to 104.1%. With these merits of high sensitivity and good selectivity and stability, the prepared aptasensor proved to be a powerful tool for evaluating contaminated cereals.

8.
Int J Biol Macromol ; 276(Pt 2): 133935, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39029851

RESUMO

Virus-induced infectious diseases have a detrimental effect on public health and exert significant influence on the global economy. Therefore, the rapid and accurate detection of viruses is crucial for effectively preventing and diagnosing infections. Aptamer-based detection technologies have attracted researchers' attention as promising solutions. Aptamers, small single-stranded DNA or RNA screened via systematic evolution of ligands by exponential enrichment (SELEX), possess a high affinity towards their target molecules. Numerous aptamers targeting viral marker proteins or virions have been developed and widely employed in aptamer-based biosensors (aptasensor) for virus detection. This review introduces SELEX schemes for screening aptamers and discusses distinctive SELEX strategies designed explicitly for viral targets. Furthermore, recent advances in aptamer-based biosensing methods for detecting common viruses using different virus-specific aptamers are summarized. Finally, limitations and prospects associated with developing of aptamer-based biosensors are discussed.

9.
ACS Sens ; 2024 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-39031767

RESUMO

Homocysteine (Hcy) and C-reactive protein (CRP) are critical biomarkers for numerous chronic diseases, with cardiovascular disease (CVD) being the most prevalent. The ability to simultaneously detect both biomarkers in point-of-care settings is in high demand for CVD early diagnosis and prevention. Herein, we prepared the eutectic gallium indium (EGaIn) nanoparticles decorated with p-phenylenediamine (PPD) on the surface to facilitate the subsequent attachment of gold nanoparticles (AuNPs) to achieve EGaIn-PPD@Au, which was modified on the screen-printed electrochemical paper-based analytical devices (ePADs). Aptamers that are specific to Hcy and CRP were then immobilized on the EGaIn-PPD@Au surface to achieve the sensing interface on ePADs. The presence of EGaIn-PPD@Au significantly enhanced the electrical conductivity, leading to amplified electrochemical signals. This aptasensor demonstrated high specificity, capable of detecting Hcy in a range of 1-50 µM with a detection limit of 0.22 µM, and the detection range for CRP was 1-100 ng/mL with a detection limit of 0.039 ng/mL. The aptasensor also effectively detected Hcy and CRP in clinical saliva samples, yielding an area under the curve (AUC) of about 0.80 when the individual biomarker was considered and 0.93 when both biomarkers were taken into account. The positive correlation observed between salivary and blood concentrations of Hcy and CRP, coupled with their association with cardiovascular disease (CVD), suggested the potential of this methodology as a noninvasive point-of-care strategy for the early diagnosis of CVD.

10.
Anal Chim Acta ; 1317: 342823, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39029996

RESUMO

BACKGROUND: Diabetes patients suffer either from insulin deficiency or resistance with a high risk of severe long-term complications, thus the quantitative assessment of insulin level is highly desired for diabetes surveillance and management. Utilizing insulin-capturing aptamers may facilitate the development of affordable biosensors however, their rigid G-quadruplex structures impair conformational changes of the aptamers and diminish the sensor signals. RESULTS: Here we report on a ratiometric, electrochemical insulin aptasensor which is achieved by hybridization of an insulin-capturing aptamer and a partially complementary ssDNA to break the rigid G-quadruplex structures. To improve the durability of the aptasensor, the capturing aptamer was immobilized on gold electrodes via two dithiol-phosphoramidite functional groups while methoxy-polyethylene glycol thiol was used as a blocking molecule. The exposure of the sensor to insulin-containing solutions induced the dissociation of the hybridized DNA accompanied by a conformational rearrangement of the capturing aptamer back into a G-quadruplex structure. The reliability of sensor readout was improved by the adoption of an AND logic gate utilizing anthraquinone and methylene blue redox probes associated to the aptamer and complementary strand, respectively. Our aptasensor possessed an improved detection limit of 0.15 nM in comparison to aptasensors without strand displacement. SIGNIFICANCE: The sensor was adapted for detection in real blood and is ready for future PoC diagnostics. The capability of monitoring the insulin level in an affordably manner can improve the treatment for an increasing number of patients in developed and developing nations. The utilization of low-cost and versatile aptamer receptors together with the engineering of ratiometric electrochemical signal recording has the potential to considerably advance the current insulin detection technology toward multi-analyte diabetes sensors.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Técnicas Eletroquímicas , Insulina , Aptâmeros de Nucleotídeos/química , Insulina/sangue , Insulina/análise , Humanos , Quadruplex G , Ouro/química , Limite de Detecção , Eletrodos
11.
Food Chem ; 460(Pt 1): 140480, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39032300

RESUMO

A novel dual-mode aptasensor was constructed for aminoglycoside antibiotics (AAs) detection by using a broad-spectrum aptamer as a biorecognition element, and Au-Pd@Fc functionalized by signal DNA as nanoprobes. In electrochemical mode, the target-induced cyclic amplification reaction run under the action of exonuclease-III, which increased the number of nanoprobes on the electrode surface. AAs could be quantitatively detected with LOD of 0.0355 ± 0.00613 nM. In colorimetric mode, the Au-Pd@Fc nanozyme catalyzed the color reaction of 3,3',5,5'-tetramethylbenzidine. The blue-shifted absorbance will be observed with the change of AAs concentration, and the LOD was 0.0458 ± 0.00572 nM. Furthermore, a magnetic molecular-imprinted material capable of specific adsorption of AAs was prepared on milk sample pretreatment. The aptasensor was used to detect 10 kinds of AAs in milk and the recoveries were 97.19 ± 4.41% âˆ¼ 98.70 ± 4.45% and 96.38 ± 3.53%-97.54 ± 4.13% in electrochemical and colorimetric methods. This work provided a theoretical basis for the application of aptamers in simultaneous detection of antibiotics.

12.
Mikrochim Acta ; 191(8): 489, 2024 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-39066938

RESUMO

A novel and simple ratiometric fluorescent aptasensor was developed for the sensitive detection of aflatoxin B1 (AFB1). A hairpin DNA (h-DNA) was independently synthesized as the basic skeleton, and the bidirectional hybridization of h-DNA can increase the load of aptamer and signal probes, thereby realizing signal amplification. The high-efficiency fluorescence resonance energy transfer interaction between gold-palladium nanoparticles (Au-Pd NPs) and the self-synthesized fluorescent probe carbon dots (CDs) was utilized. Moreover, the label-free probe SYBR Green I (SG I) dye was introduced to form a double-signal probe with CDs, and a ratiometric sensor with FCDs/FSG I as a response signal was constructed. The ratio strategy can eliminate the fluctuation of external factors, thus improving the accuracy and reliability of the sensor. The quenching effect of Au-Pd NPs on CDs was 1.4 times that of AuNPs and 3.4 times that of Pd NPs, respectively. In the range 1-100 ng/mL, FCDs/FSG I showed a good linear relationship with the logarithm of the concentration of AFB1, and the limit of detection was as low as 0.07 ng/mL. The sensor was used to detect AFB1 in spiked peanuts and wine samples, and the recovery was between 91 and 115%, indicating that the sensor has high application potential in real sample analysis.


Assuntos
Aflatoxina B1 , Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Carbono , Corantes Fluorescentes , Ouro , Limite de Detecção , Nanopartículas Metálicas , Paládio , Pontos Quânticos , Ouro/química , Aflatoxina B1/análise , Paládio/química , Nanopartículas Metálicas/química , Aptâmeros de Nucleotídeos/química , Corantes Fluorescentes/química , Técnicas Biossensoriais/métodos , Carbono/química , Pontos Quânticos/química , Hibridização de Ácido Nucleico , Vinho/análise , DNA/química , Transferência Ressonante de Energia de Fluorescência/métodos , Arachis/química , Sequências Repetidas Invertidas
13.
Indian J Med Microbiol ; : 100694, 2024 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-39074769

RESUMO

BACKGROUND: Aptamers are not so new a concept, however, it is scarcely discussed by medical fraternity. Aptamers are potent, new identification molecules set to rope in a new technique in the diagnostic arena. Aptamers have started almost a revolution in diagnostic assays since their discovery in the 90s. (Radu S. Current and previous disease outbreaks around the world, U.S. News & World Report. 2020 Mar 13 [cited 2024 Jun 17]. Available from: https://www.usnews.com/news/best-countries/slideshows/20-pandemic-and-epidemic-diseases-according-to-who) provides an overview of pandemics and epidemics as reported by the WHO. It is interesting to note that several endemic and epidemic diseases viz. Chikungunya, Cholera, Crimean-Congo haemorrhagic fever, Ebola virus disease, Hendra virus infection, Influenza, Lassa fever, Marburg virus disease, Meningitis, MERS-CoV (Middle East Respiratory Syndrome Corona Virus), Monkeypox, Nipah virus infection, Novel coronavirus, Plague, Rift Valley fever, SARS (Severe Acute Respiratory Syndrome), Smallpox, Tularaemia, Yellow fever, and Zika virus disease have been identified by the WHO and are being explored for applicability of aptamer technology in their identification. OBJECTIVES: One of the most important necessities to control epidemic or pandemic diseases is early diagnosis. However, the majority of the diagnostic tests for these diseases are available only in tertiary care centres. The objective of this review is to discuss the potential of aptamer technology to provide undemanding, simple, specific, sensitive, and cost-effective diagnostic assays that are usable in remote and field conditions. CONTENT: Here, we discuss recent advances and approaches in aptamer and aptamer engineering useful in the diagnosis of infectious and non-infectious conditions. This review also discusses a few sensing discoveries which are a gift of advanced engineering and technology using optical and electrochemical aptasensors. It's still a long way to go, and we need to take into account the technological challenges being faced by aptamer-aptasensor technology.

14.
Food Chem ; 458: 140306, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38968710

RESUMO

This study focused on detecting streptomycin (STR) residues using a luminescent aptasensor encapsulated with aptamer. Utilizing MOF-74-Co with peroxidase-like activity, luminol was enclosed in its pores. The specific STR aptamer acted as a gatekeeper, ensuring excellent performance. Upon exposure to STR, the aptamers detached, releasing luminol and amplifying the luminescent signal through MOF-74-Co catalytic activity. A linear relationship between fluorescence intensity and STR concentration (50 nM âˆ¼ 5 × 106 nM) was established, with a limit of detection of 0.065 nM. The sensor exhibited high selectivity for STR even in the presence of other aminoglycoside antibiotics. Applied to tea, egg, and honey samples, the sensor showed recovery rates of 91.38-100.2%, meeting safety standards. This MOF-based aptasensor shows promise for detecting harmful residues.

15.
Anal Chim Acta ; 1316: 342867, 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-38969430

RESUMO

BACKGROUND: Kanamycin (KAN) residues in animal-derived foods continuously enter the human body, which will pose serious threats to human health such as hearing loss, nephrotoxicity and other complications. Therefore, to sensitively detect KAN residues by a reliable technology is extremely urgent in food quality and safety. Compared with traditional methods being limited by cost and complexity, photoelectrochemical (PEC) biosensors benefit from some merits such as rapid response, excellent sensitivity and good stability. In this study, the construction of a highly efficient PEC platform to realize KAN residues detection is discussed. RESULTS: Herein, a novel p-n heterojunction consisting of flower-like BiOI microspheres and graphite carbon nitride (g-C3N4) nanoflakes was developed to establish a PEC aptasensor for KAN detection at 0 V. The prepared g-C3N4/BiOI heterostructure showed not only significantly enhanced PEC activity due to the larger specific surface area but also greatly increased charge separation efficiency owing to the strong internal electric field. Meanwhile, using g-C3N4/BiOI as a highly efficient photoactive material for binding amine-functionalized aptamers to capture KAN, the photocurrent signals showed a 'turn off' mode to achieve the sensitive detection of KAN. The proposed PEC aptasensor exhibited linear response for KAN from 5 × 10-9 to 3 × 10-7 mol L-1 with a low detection limit of 1.31 × 10-9 mol L-1, and satisfactory recoveries (97.44-107.38 %) were obtained in real food samples analysis. SIGNIFICANCE: This work presented a novel p-n heterojunction-based PEC aptasensor with strong selectivity and stability, rendering it allowed to detect KAN in animal-derived foods including milk, honey and pork. Additionally, the detection range satisfied the MRLs for KAN specified by the national standards, demonstrating the potential application for food analysis. The study provides a new insight into the development of efficient and practical biosensors for antibiotic residues detection.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Técnicas Eletroquímicas , Grafite , Canamicina , Aptâmeros de Nucleotídeos/química , Técnicas Eletroquímicas/métodos , Grafite/química , Técnicas Biossensoriais/métodos , Canamicina/análise , Processos Fotoquímicos , Limite de Detecção , Contaminação de Alimentos/análise , Compostos de Nitrogênio/química , Animais , Nitrilas/química , Antibacterianos/análise , Bismuto
16.
Anal Chim Acta ; 1317: 342920, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39030014

RESUMO

BACKGROUND: As a broad-spectrum tetracycline antibiotic, Oxytetracycline (OTC) was widely used in a variety of applications. But, the overuse of OTC had led to the detection of it in food, water and soil, which could present significance risk to human health and cause damage to ecosystem. It was of great significance to develop sensitive detection methods for OTC. Herein, an environmentally friendly photoelectrochemical (PEC) aptasensor was constructed for the sensitive detection of OTC based on CuO-induced BiOBr/Ag2S/PDA (Polydopamine) photocurrent polarity reversal. RESULTS: BiOBr/Ag2S/PDA composites modified electrode not only produced stable initial anodic photocurrent but also provided attachment sites for the aptamer S1 of OTC by the strong adhesion of PDA. On the other hand, CuO loaded OTC aptamer S2 (Cu-S2) was got through Cu-S bonds. After the target OTC was identified on the electrode surface, CuO was introduced to the surface of ITO/BiOBr/Ag2S/PDA through the specific binding of OTC to S2. This identification process formed dual Z-type heterojunctions and resulted in a remarkable reversal of photocurrent polarity from anodic to cathodic. Under optimization conditions, the PEC aptasensor showed a wide linear range (50 fM âˆ¼ 100 nM), low detection limit (1.9 fM), excellent selectivity, stability and reproducibility for the detection of OTC. Moreover, it was successfully used for the analysis of OTC in real samples of tap water, milk and honey, and had the potential for practical application. SIGNIFICANCE: This work developed an environmentally friendly photocurrent-polarity-switching PEC aptasensor with excellent selectivity, reproducibility, stability, low LOD and wide linear range for OTC detection. This sensitive system, which was including BiOBr, Ag2S, PDA and CuO were low toxicity, not only reduced the risk of traditional toxic semiconductors to operators and the environment, but can also be used for the detection of real samples, broadening the wider range of applications for BiOBr, Ag2S, PDA and CuO.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Bismuto , Cobre , Técnicas Eletroquímicas , Oxitetraciclina , Oxitetraciclina/análise , Cobre/química , Aptâmeros de Nucleotídeos/química , Técnicas Eletroquímicas/métodos , Bismuto/química , Processos Fotoquímicos , Compostos de Prata/química , Polímeros/química , Eletrodos , Animais , Limite de Detecção , Indóis/química , Antibacterianos/análise , Antibacterianos/química
17.
Molecules ; 29(13)2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38998965

RESUMO

In this study, a self-responsive fluorescence aptasensor was established for the determination of lactoferrin (Lf) in dairy products. Herein, the aptamer itself functions as both a recognition element that specifically binds to Lf and a fluorescent signal reporter in conjunction with fluorescent moiety. In the presence of Lf, the aptamer preferentially binds to Lf due to its specific and high-affinity recognition by folding into a self-assembled and three-dimensional spatial structure. Meanwhile, its reduced spatial distance in the aptamer-Lf complex induces a FRET phenomenon based on the quenching of 6-FAM by amino acids in the Lf protein, resulting in a turn-off of the fluorescence of the system. As a result, the Lf concentration can be determined straightforwardly corresponding to the change in the self-responsive fluorescence signal. Under the optimized conditions, good linearities (R2 > 0.99) were achieved in an Lf concentration range of 2~10 µg/mL for both standard solutions and the spiked matrix, as well as with the desirable detection limits of 0.68 µg/mL and 0.46 µg/mL, respectively. Moreover, the fluorescence aptasensor exhibited reliable recoveries (89.5-104.3%) in terms of detecting Lf in three commercial samples, which is comparable to the accuracy of the HPCE method. The fluorescence aptasensor offers a user-friendly, cost-efficient, and promising sensor platform for point-of-need detection.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Laticínios , Lactoferrina , Lactoferrina/análise , Lactoferrina/química , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , Laticínios/análise , Fluorescência , Limite de Detecção , Espectrometria de Fluorescência/métodos , Análise de Alimentos/métodos , Transferência Ressonante de Energia de Fluorescência/métodos
18.
Int J Mol Sci ; 25(13)2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38999943

RESUMO

Aptamers are short oligonucleotides with single-stranded regions or peptides that recently started to transform the field of diagnostics. Their unique ability to bind to specific target molecules with high affinity and specificity is at least comparable to many traditional biorecognition elements. Aptamers are synthetically produced, with a compact size that facilitates deeper tissue penetration and improved cellular targeting. Furthermore, they can be easily modified with various labels or functional groups, tailoring them for diverse applications. Even more uniquely, aptamers can be regenerated after use, making aptasensors a cost-effective and sustainable alternative compared to disposable biosensors. This review delves into the inherent properties of aptamers that make them advantageous in established diagnostic methods. Furthermore, we will examine some of the limitations of aptamers, such as the need to engage in bioinformatics procedures in order to understand the relationship between the structure of the aptamer and its binding abilities. The objective is to develop a targeted design for specific targets. We analyse the process of aptamer selection and design by exploring the current landscape of aptamer utilisation across various industries. Here, we illuminate the potential advantages and applications of aptamers in a range of diagnostic techniques, with a specific focus on quartz crystal microbalance (QCM) aptasensors and their integration into the well-established ELISA method. This review serves as a comprehensive resource, summarising the latest knowledge and applications of aptamers, particularly highlighting their potential to revolutionise diagnostic approaches.


Assuntos
Aptâmeros de Nucleotídeos , Biomarcadores , Técnicas Biossensoriais , Técnica de Seleção de Aptâmeros , Aptâmeros de Nucleotídeos/química , Aptâmeros de Nucleotídeos/metabolismo , Humanos , Técnica de Seleção de Aptâmeros/métodos , Técnicas Biossensoriais/métodos , Anticorpos/imunologia , Anticorpos/química , Animais , Técnicas de Microbalança de Cristal de Quartzo/métodos , Ensaio de Imunoadsorção Enzimática/métodos
19.
Talanta ; 278: 126470, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38996565

RESUMO

The Rubella virus (RUBV) is a highly contagious pathogen classified within the rubivirus genus, primarily infecting humans and transmitted via airborne routes. RUBV infection generally manifests as a mild illness reminiscent of measles. However, when affecting pregnant women, it can lead to a severe condition known as congenital rubella syndrome (CRS). Rubella infection could be also associated with joint pain, arthritis, and neurological disorders. Determination of Rubella immunity and diagnosis conventionally involve the Hemagglutination Inhibition (HI) test or the Enzyme-Linked Immunosorbent Assay (ELISA). In this study, we describe the selection and characterization of specific aptamers targeting the Rubella virus by using the process of Systematic Evolution of Ligands by EXponantial enrichment (SELEX). The Binding affinity studies have shown that the two aptamers; R-7 and R-5 display the lowest dissociation constants (Kd) of 6.58 nM and 19.05 nM, respectively. Then, R-7 aptamer was modified with a thiol group to enable its immobilization on screen-printed gold electrodes for the Rubella virus aptasensing. The label-free electrochemical detection was achieved using square wave voltammetry (SWV). The designed aptasensor has shown an excellent performance in detecting the Rubella virus within the range of 0.0005 ng/ml to 1000 ng/ml antigen and a limit of detection (LOD) of 0.00015 ng/ml. Selectivity studies were also performed against other viral antigens and serum proteins. Finally, the biosensor applicability was successfully demonstrated in spiked serum samples.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Técnicas Eletroquímicas , Vírus da Rubéola , Vírus da Rubéola/química , Vírus da Rubéola/isolamento & purificação , Vírus da Rubéola/imunologia , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Técnica de Seleção de Aptâmeros , Humanos , Eletrodos , Limite de Detecção , Ouro/química
20.
Cell Mol Bioeng ; 17(3): 229-241, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39050512

RESUMO

Purpose: Waterborne pathogens pose a significant threat to public health, emphasizing the continuous necessity for advancing robust detection techniques, particularly in preventing outbreaks associated with these pathogens. This study focuses on cholera, an infectious disease caused by Vibrio cholerae, serogroups O1 and O139, often transmitted through contaminated water and food, raising significant public health concerns in areas with poor sanitation and limited access to clean water. Methods: We developed a colorimetric biosensor using aptamer-functionalized gold nanoparticles to identify Vibrio cholerae O139 and address this issue. The detection mechanism relies on the color change of gold nanoparticles (AuNPs) from red to blue-purple induced by NaCl after the pathogen incubation and aptamer-target binding. Initial steps involved synthesizing and characterizing AuNPs, then exploring the impact of aptamer and NaCl concentrations on AuNP agglomeration. Optimization procedures for aptamer concentration and salt addition identified the optimal conditions for detection as 120 pM aptamers and 1 M NaCl. Results: The aptasensor demonstrated a robust linear relationship, detecting V. cholerae concentrations from 103 to 108 CFU/mL, with a limit of detection (LOD) of 587 CFU/mL. Specificity tests and accurate sample analyses confirmed the efficiency of the AuNPs aptasensor, showcasing its reliability and speed compared to traditional culture examination methods. Moreover, we extended the aptasensor to a paper-based sensing platform with similar detection principles. Conclusion: The change in color upon target binding was captured with a smartphone and analyzed using image processing software. The paper-based device detected the target in less than 2 min, demonstrating its convenience for on-field applications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...