Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Med Devices (Auckl) ; 17: 89-95, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38404633

RESUMO

Background: Multiple needle punctures during central venous line insertion can lead to serious complications. Needle deterioration owing to repeated punctures may be a major cause. We hypothesized that there is an optimal bevel angle for a back-cut point needle that is resistant to deterioration. In this study, we examined the effect of bevel angle differences in a back-cut point needle on needle tip deterioration caused by multiple punctures. Methods: The resin target was punctured perpendicularly using back-cut point needles with three bevel angles (15°, 17°, and 19°; n=8 for each angle) at a speed of 200 mm/min. The same needle was used for ten consecutive punctures at different locations on the target. The force applied to the needle was recorded as puncture force. The puncture force waveform is bimodal. The second peak values, which formed the maximum values of puncture force, were the focus of the main analysis. We considered a 5% elevation from the first to the 10th puncture force as needle deterioration, and the average slope value of the regression line between the puncture number and puncture force was used. When the upper limit of the 95% confidence interval (CI) of the slope value was less than 0.008889, the needle was considered to be resistant to deterioration. Results: The slopes of the second peak values during 10 consecutive punctures for each bevel angle (15°, 17°, 19°) were 0.003011 ± 0.01085 [-0.006056, 0.012077], 0.006116±0.007431 [-0.000096, 0.012328], and 0.001515 ± 0.005783 [-0.003320, 0.006349], respectively (mean ± standard deviation [95% CI]). Only the 19° angle needle had a smaller upper limit of the 95% CI for a slope value of 0.008889. Conclusion: The 19° bevel angle back-cut point needle was more resistant to deterioration than the 15° and 17° angle needles were.

2.
J Vasc Access ; 21(6): 969-976, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32372685

RESUMO

BACKGROUND: Peripheral intravenous catheter placement is frequently unsuccessful at the first attempt. One suggested risk factor is a small vein size, because of the consequences of mechanical forces generated by the needle tip. We developed short bevel needles with a very thin tip and evaluated their puncture performance in two in vitro models. METHODS: Peripheral intravenous catheters with a new needle ground using the lancet method (experimental catheter (L)) or backcut method (experimental catheter (B)) were compared with a conventional peripheral intravenous catheter (Surshield Surflo®) in a penetration force test and a tube puncture test. Penetration forces were measured when peripheral intravenous catheters penetrated a polyethylene sheet. The tube puncture test was used to evaluate whether the peripheral intravenous catheters could puncture a polyvinyl chloride tube at two positions, at the center and at 0.5 mm from the center of the tube. RESULTS: Mean penetration forces at the needle tip produced by experimental catheters (L) (0.05 N) and (B) (0.04 N) were significantly lower than those produced by the conventional catheter (0.09 N) (p < 0.01). At the catheter tip, mean forces produced by experimental catheter (B) and the conventional catheter were 0.16 N and 0.26 N, respectively (p < 0.05). In the tube puncture test, the frequency at which the conventional catheter punctured the center-shifted site on the tube at an angle of 20° and speed of 50 mm/min was low (40%). In contrast, experimental catheters (L) and (B) were 100% successful at puncturing both the center and center-shifted sites at 20°. CONCLUSION: Puncture performance was comparable between the lancet-ground and backcut-ground needles except for penetration forces at the catheter tip. The experimental catheters produced lower penetration forces and induced puncture without target displacement at smaller angles compared with the conventional catheter. Therefore, optimization of the needle can prevent vein deformation and movement, which may increase the first-attempt success rate.


Assuntos
Cateterismo Periférico/instrumentação , Agulhas , Dispositivos de Acesso Vascular , Veias , Substâncias Antieletricidade Estática , Cateterismo Periférico/efeitos adversos , Desenho de Equipamento , Punções
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...