Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 364
Filtrar
1.
J Breath Res ; 18(4)2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39260379

RESUMO

Untargeted analysis of volatile organic compounds (VOCs) from exhaled breath and culture headspace are influenced by several confounding factors not represented in reference standards. In this study, we propose a method of generating pooled quality control (QC) samples for untargeted VOC studies using a split-recollection workflow with thermal desorption tubes. Sample tubes were desorbed and split from each sample and recollected onto a single tube, generating a pooled QC sample. This QC sample was then repeatedly desorbed and recollected with a sequentially lower split ratio allowing injection of multiple QC samples. We found pooled QC samples to be representative of complex mixtures using principal component analysis and may be useful in future longitudinal, multi-centre, and validation studies to assess data quality and adjust for batch effects.


Assuntos
Testes Respiratórios , Controle de Qualidade , Compostos Orgânicos Voláteis , Compostos Orgânicos Voláteis/análise , Humanos , Testes Respiratórios/métodos , Testes Respiratórios/instrumentação , Expiração , Cromatografia Gasosa-Espectrometria de Massas
2.
Metabolomics ; 20(5): 102, 2024 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-39242444

RESUMO

INTRODUCTION: Volatile organic compounds (VOCs) can arise from underlying metabolism and are detectable in exhaled breath, therefore offer a promising route to non-invasive diagnostics. Robust, precise, and repeatable breath measurement platforms able to identify VOCs in breath distinguishable from background contaminants are needed for the confident discovery of breath-based biomarkers. OBJECTIVES: To build a reliable breath collection and analysis method that can produce a comprehensive list of known VOCs in the breath of a heterogeneous human population. METHODS: The analysis cohort consisted of 90 pairs of breath and background samples collected from a heterogenous population. Owlstone Medical's Breath Biopsy® OMNI® platform, consisting of sample collection, TD-GC-MS analysis and feature extraction was utilized. VOCs were determined to be "on-breath" if they met at least one of three pre-defined metrics compared to paired background samples. On-breath VOCs were identified via comparison against purified chemical standards, using retention indexing and high-resolution accurate mass spectral matching. RESULTS: 1471 VOCs were present in > 80% of samples (breath and background), and 585 were on-breath by at least one metric. Of these, 148 have been identified covering a broad range of chemical classes. CONCLUSIONS: A robust breath collection and relative-quantitative analysis method has been developed, producing a list of 148 on-breath VOCs, identified using purified chemical standards in a heterogenous population. Providing confirmed VOC identities that are genuinely breath-borne will facilitate future biomarker discovery and subsequent biomarker validation in clinical studies. Additionally, this list of VOCs can be used to facilitate cross-study data comparisons for improved standardization.


Assuntos
Testes Respiratórios , Cromatografia Gasosa-Espectrometria de Massas , Compostos Orgânicos Voláteis , Compostos Orgânicos Voláteis/análise , Testes Respiratórios/métodos , Humanos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Biomarcadores/análise , Idoso , Adulto Jovem , Expiração
3.
J Breath Res ; 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39332452

RESUMO

For decades, intake monitoring of drugs using urine as the matrix of choice is the gold standard in drug treatment centers. A properly conducted urine drug test can identify recent use of prescribed, non-prescribed and illicit drugs. However, issues like adulteration, substitution and privacy issues have driven the search for alternative matrices. This prospective pilot study evaluates the use of an impaction-based breath sampling device, Breath Explor®, as an alternative to traditional urine-based drug monitoring. Breath samples were analyzed using a validated 32-component liquid chromatography-tandem mass spectrometry (LC-MSMS) method. Recovery data represent the efficiency of extracting the analytes from the breath devices. Both automated and manual processing of the Breath Explor® devices showed mean recovery rates ranging from 39.5% to 55.4% for the 32 analytes. Despite the small number of subjects, breath analysis proved to be a convenient and easy-to-use methodology. An overall kappa-values of 0.5 indicated a moderate level of agreement with urine analysis, underscoring its potential as a complementary diagnostic tool. All participants tested positive in their breath sample for methadone (70% methadone and 100% EDDP), while a significant portion (90%) tested positive for 6-monoacetylmorphine (6-MAM). This innovative approach offers several advantages, including non-invasiveness, reduced risk of adulteration, and the ability to perfom repeated automated sampling and confirmation testing. These findings suggest that breath-based substance monitoring could complement or even replace traditional urine-based methods in clinical practice.

4.
Nano Lett ; 24(33): 10139-10147, 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39109658

RESUMO

Surface-enhanced Raman scattering (SERS) offers a promising, cost-effective alternative for the rapid, sensitive, and quantitative analysis of potential biomarkers in exhaled gases, which is crucial for early disease diagnosis. However, a major challenge in SERS is the effective detection of gaseous analytes, primarily due to difficulties in enriching and capturing them within the substrate's "hotspot" regions. This study introduces an advanced gas sensor combining mesoporous gold (MesoAu) and metal-organic frameworks (MOFs), exhibiting high sensitivity and rapid detection capabilities. The MesoAu provides abundant active sites and interconnected mesopores, facilitating the diffusion of analytes for detection. A ZIF-8 shell enveloping MesoAu further enriches target molecules, significantly enhancing sensitivity. A proof-of-concept experiment demonstrated a detection limit of 0.32 ppb for gaseous benzaldehyde, indicating promising prospects for the rapid diagnosis of early stage lung cancer. This research also pioneers a novel approach for constructing hierarchical plasmonic nanostructures with immense potential in gas sensing.


Assuntos
Testes Respiratórios , Gases , Ouro , Estruturas Metalorgânicas , Análise Espectral Raman , Estruturas Metalorgânicas/química , Testes Respiratórios/métodos , Ouro/química , Gases/análise , Gases/química , Humanos , Análise Espectral Raman/métodos , Porosidade , Nanoestruturas/química , Benzaldeídos/química , Limite de Detecção , Nanopartículas Metálicas/química
5.
J Breath Res ; 18(4)2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39089291

RESUMO

Polymeric bags are a widely applied, simple, and cost-effective method for the storage and offline analysis of gaseous samples. Various materials have been used as sampling bags, all known to contain impurities and differing in their cost, durability, and storage capabilities. Herein, we present a comparative study of several well-known bag materials, Tedlar (PVF), Kynar (PVDF), Teflon (PTFE), and Nalophan (PET), as well as a new material, ethylene vinyl copolymer (EVOH), commonly used for storing food. We investigated the influences of storage conditions, humidity, bag cleaning, and light exposure on volatile organic compound concentration (acetone, acetic acid, isoprene, benzene, limonene, among others) in samples of exhaled human breath stored in bags for up to 48 h. Specifically, we show high losses of short-chain fatty acids (SCFAs) in bags of all materials (for most SCFAs, less than 50% after 8 h of storage). We found that samples in Tedlar, Nalophan, and EVOH bags undergo changes in composition when exposed to UV radiation over a period of 48 h. We report high initial impurity levels in all the bags and their doubling after a period of 48 h. We compare secondary electrospray ionization and proton transfer reaction mass spectrometry in the context of offline analysis after storage in sampling bags. We provide an analytical perspective on the temporal evolution of bag contents by presenting the intensity changes of all significantm/zfeatures. We also present a simple, automated, and cost-effective offline sample introduction system, which enables controlled delivery of collected gaseous samples from polymeric bags into the mass spectrometer. Overall, our findings suggest that sampling bags exhibit high levels of impurities, are sensitive to several environmental factors (e.g. light exposure), and provide low recoveries for some classes of compounds, e.g. SCFAs.


Assuntos
Testes Respiratórios , Polímeros , Humanos , Testes Respiratórios/instrumentação , Testes Respiratórios/métodos , Polímeros/análise , Compostos Orgânicos Voláteis/análise , Expiração , Manejo de Espécimes/métodos , Manejo de Espécimes/instrumentação
6.
J Biophotonics ; 17(10): e202400151, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39075328

RESUMO

Early diagnosis is crucial for effective treatment of socially significant diseases, such as type 1 diabetes mellitus (T1DM), pneumonia, and asthma. This study employs a diagnostic method based on infrared laser spectroscopy of human exhaled breath. The experimental setup comprises a quantum cascade laser, which emits in a pulsed mode with a peak power of up to 150 mW in the spectral range of 5.3-12.8 µm (780-1890 cm-1), and a Herriott multipass gas cell with a specific optical path length of 76 m. Using this setup, spectra of exhaled breath in the mid-infrared range were obtained from 165 volunteers, including healthy individuals, patients with T1DM, asthma, and pneumonia. The study proposes a hybrid approach for classifying these spectra, utilizing a variational autoencoder for dimensionality reduction and a support vector machine method for classification. The results demonstrate that the proposed hybrid approach outperforms other machine learning method combinations.


Assuntos
Testes Respiratórios , Expiração , Espectrofotometria Infravermelho , Humanos , Testes Respiratórios/métodos , Aprendizado de Máquina , Asma/diagnóstico , Asma/metabolismo , Diabetes Mellitus Tipo 1/metabolismo , Masculino , Adulto , Máquina de Vetores de Suporte , Pneumonia/diagnóstico por imagem , Pneumonia/metabolismo , Feminino , Fenômenos Ópticos
7.
EXCLI J ; 23: 795-810, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38983779

RESUMO

There is an apparent need for novel non-invasive colorectal cancer (CRC) screening tests that are more acceptable to patients and can reliably detect CRC or reduce the number of unnecessary colonoscopies performed in cancer-free patients. An emerging number of studies demonstrate the potential value of exhaled volatile organic compounds (VOCs) as a diagnostic and triaging test for CRC. A systematic appraisal and meta-analysis of the published evidence was done to determine whether exhaled VOCs can be used in the detection and screening of CRC. Nine electronic databases were searched from inception of the databases until August 2020. Quantitative and descriptive data of CRC patients and healthy control (HC) participants who underwent VOCs breath analysis was extracted. In addition, where possible, sampling methods, analytical platforms, processors, and specific breath biomarkers found in each study were recorded. Fourteen articles were included in the systematic review with 491 colorectal patients and 754 HC participants (n=1245). Sub-group meta-analysis was conducted on nine of those articles and the pooled sensitivity was estimated to be 0.89 (95 % CI = 0.80-0.99) whereas specificity was 0.83 (95 % CI = 0.74-0.92). Heterogeneity of pooled sensitivity and specificity was estimated as I2=11.11 %. Although this study was limited by small sample size and different analytical platforms, the proposed future framework resolves such limitations and standardizes future research. It is reasonable to deduce that VOCs breath analysis is certainly a field of research that can progress to replace traditional methods within the framework of CRC screening and diagnosis.

8.
Anal Bioanal Chem ; 416(22): 4929-4939, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38980330

RESUMO

Exhaled breath volatilomics is a powerful non-invasive tool for biomarker discovery in medical applications, but compound annotation is essential for pathophysiological insights and technology transfer. This study was aimed at investigating the interest of a hybrid approach combining real-time proton transfer reaction-time-of-flight mass spectrometry (PTR-TOF-MS) with comprehensive thermal desorption-two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (TD-GCxGC-TOF-MS) to enhance the analysis and characterization of VOCs in clinical research, using COVID-19 as a use case. VOC biomarker candidates were selected from clinical research using PTR-TOF-MS fingerprinting in patients with COVID-19 and matched to the Human Breathomic Database. Corresponding analytical standards were analysed using both a liquid calibration unit coupled to PTR-TOF-MS and TD-GCxGC-TOF-MS, together with confirmation on new clinical samples with TD-GCxGC-TOF-MS. From 26 potential VOC biomarkers, 23 were successfully detected with PTR-TOF-MS. All VOCs were successfully detected using TD-GCxGC-TOF-MS, providing effective separation of highly chemically related compounds, including isomers, and enabling high-confidence annotation based on two-dimensional chromatographic separation and mass spectra. Four VOCs were identified with a level 1 annotation in the clinical samples. For future applications, the combination of real-time PTR-TOF-MS and comprehensive TD-GCxGC-TOF-MS, at least on a subset of samples from a whole study, would enhance the performance of VOC annotation, offering potential advancements in biomarker discovery for clinical research.


Assuntos
Biomarcadores , Testes Respiratórios , COVID-19 , Compostos Orgânicos Voláteis , Humanos , Testes Respiratórios/métodos , Biomarcadores/análise , Compostos Orgânicos Voláteis/análise , COVID-19/diagnóstico , Cromatografia Gasosa-Espectrometria de Massas/métodos , Espectrometria de Massas/métodos , Expiração , SARS-CoV-2
9.
Metabolomics ; 20(4): 79, 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39046579

RESUMO

INTRODUCTION: This study employs Proton-Transfer-Reaction Mass Spectrometry (PTR-MS) to analyze exhaled breath profiles of 504 healthy adults, focusing on nine common volatile organic compounds (VOCs): acetone, acetaldehyde, acetonitrile, ethanol, isoprene, methanol, propanol, phenol, and toluene. PTR-MS offers real-time VOC measurement, crucial for understanding breath biomarkers and their applications in health assessment. OBJECTIVES: The study aims to investigate how demographic factors-gender, age, and smoking history-affect VOC concentrations in exhaled breath. The objective is to enhance our understanding of breath biomarkers and their potential for health monitoring and clinical diagnosis. METHODS: Exhaled breath samples were collected using PTR-MS, measuring concentrations of nine VOCs. The data were analyzed to discern distribution patterns across demographic groups. RESULTS: Males showed higher average VOC levels for certain compounds. Propanol and methanol concentrations significantly increased with age. Smoking history influenced VOC levels, with differences among non-smokers, current smokers, and ex-smokers. CONCLUSION: This research provides valuable insights into demographic influences on exhaled VOC profiles, emphasizing the potential of breath analysis for health assessment. PTR-MS's real-time measurement capabilities are crucial for capturing dynamic VOC changes, offering advantages over conventional methods. These findings lay a foundation for advancements in non-invasive disease detection, highlighting the importance of considering demographics in breath biomarker research.


Assuntos
Testes Respiratórios , Voluntários Saudáveis , Espectrometria de Massas , Compostos Orgânicos Voláteis , Humanos , Masculino , Testes Respiratórios/métodos , Feminino , Compostos Orgânicos Voláteis/análise , Adulto , Pessoa de Meia-Idade , Espectrometria de Massas/métodos , Adulto Jovem , Idoso , Expiração , Biomarcadores/análise , Adolescente , Fumar/metabolismo
10.
Metabolomics ; 20(4): 72, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38977623

RESUMO

BACKGROUND: The multitude of metabolites generated by physiological processes in the body can serve as valuable biomarkers for many clinical purposes. They can provide a window into relevant metabolic pathways for health and disease, as well as be candidate therapeutic targets. A subset of these metabolites generated in the human body are volatile, known as volatile organic compounds (VOCs), which can be detected in exhaled breath. These can diffuse from their point of origin throughout the body into the bloodstream and exchange into the air in the lungs. For this reason, breath VOC analysis has become a focus of biomedical research hoping to translate new useful biomarkers by taking advantage of the non-invasive nature of breath sampling, as well as the rapid rate of collection over short periods of time that can occur. Despite the promise of breath analysis as an additional platform for metabolomic analysis, no VOC breath biomarkers have successfully been implemented into a clinical setting as of the time of this review. AIM OF REVIEW: This review aims to summarize the progress made to address the major methodological challenges, including standardization, that have historically limited the translation of breath VOC biomarkers into the clinic. We highlight what steps can be taken to improve these issues within new and ongoing breath research to promote the successful development of the VOCs in breath as a robust source of candidate biomarkers. We also highlight key recent papers across select fields, critically reviewing the progress made in the past few years to advance breath research. KEY SCIENTIFIC CONCEPTS OF REVIEW: VOCs are a set of metabolites that can be sampled in exhaled breath to act as advantageous biomarkers in a variety of clinical contexts.


Assuntos
Biomarcadores , Testes Respiratórios , Expiração , Metabolômica , Compostos Orgânicos Voláteis , Humanos , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/metabolismo , Testes Respiratórios/métodos , Biomarcadores/metabolismo , Biomarcadores/análise , Metabolômica/métodos
11.
J Chromatogr A ; 1730: 465125, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-38970877

RESUMO

In this study, we aimed to assess the feasibility of re-collecting breath samples using the Centri® (Markes International, Bridgend, UK) followed by two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC×GC-TOFMS) analysis. The work was conducted in two main phases. In the first phase, we evaluated the re-collection performance by analyzing two sets of standards, including a Grob mix primary solution and a standard mixture of 20 selected volatile compounds (VCs) covering different classes of organic species commonly found in breath samples. The intra-day and inter-day precision (reported as relative standard deviation (RSD),%) for the re-collection of the Grob mix primary solution were in the range of 1 % to14 % and 3 % to12 %, respectively. The re-collection accuracy ranged from 78 % to 97 %. The intra-day RSD for the re-collection of the standard mixture of selected VCs was within 20 % for all compounds, except for acetone and nonane. The precision was within 25 % for all compounds, except for nonane, n-hexane, 1,4-dichlorobenzene, and decane, which exhibited less than 36 % RSD. The re-collection accuracy was in the range of 67 % to 129 %. In the second phase of the study, the re-collection performance in breath analysis was evaluated via five repetitive splitting and re-collection of six breath samples obtained from healthy adults, realizing a total of 30 breath analyses. Initially, we evaluated the re-collection performance by considering all features obtained from breath analysis and then focused on the 20 VCs commonly found in breath samples. The re-collection accuracy for total breath features ranged from 86 to 103 %, and the RSDs were in the range of 1.0 % to 10.4 %. For the selected VCs, the re-collection accuracy of all compounds, except for undecane and benzene, was in the range of 71 % to 132 %.


Assuntos
Testes Respiratórios , Estudos de Viabilidade , Cromatografia Gasosa-Espectrometria de Massas , Compostos Orgânicos Voláteis , Compostos Orgânicos Voláteis/análise , Humanos , Testes Respiratórios/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Masculino , Adulto , Feminino , Reprodutibilidade dos Testes , Pessoa de Meia-Idade , Adulto Jovem , Manejo de Espécimes/métodos
12.
Sci Rep ; 14(1): 14568, 2024 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-38914586

RESUMO

COVID-19 has caused a worldwide pandemic, creating an urgent need for early detection methods. Breath analysis has shown great potential as a non-invasive and rapid means for COVID-19 detection. The objective of this study is to detect patients infected with SARS-CoV-2 and even the possibility to screen between different SARS-CoV-2 variants by analysis of carbonyl compounds in breath. Carbonyl compounds in exhaled breath are metabolites related to inflammation and oxidative stress induced by diseases. This study included a cohort of COVID-19 positive and negative subjects confirmed by reverse transcription polymerase chain reaction between March and December 2021. Carbonyl compounds in exhaled breath were captured using a microfabricated silicon microreactor and analyzed by ultra-high-performance liquid chromatography-mass spectrometry (UHPLC-MS). A total of 321 subjects were enrolled in this study. Of these, 141 (85 males, 60.3%) (mean ± SD age: 52 ± 15 years) were COVID-19 (55 during the alpha wave and 86 during the delta wave) positive and 180 (90 males, 50%) (mean ± SD age: 45 ± 15 years) were negative. Panels of a total of 34 ketones and aldehydes in all breath samples were identified for detection of COVID-19 positive patients. Logistic regression models indicated high accuracy/sensitivity/specificity for alpha wave (98.4%/96.4%/100%), for delta wave (88.3%/93.0%/84.6%) and for all COVID-19 positive patients (94.7%/90.1%/98.3%). The results indicate that COVID-19 positive patients can be detected by analysis of carbonyl compounds in exhaled breath. The technology for analysis of carbonyl compounds in exhaled breath has great potential for rapid screening and detection of COVID-19 and for other infectious respiratory diseases in future pandemics.


Assuntos
Testes Respiratórios , COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , COVID-19/virologia , Testes Respiratórios/métodos , Masculino , Pessoa de Meia-Idade , Feminino , Adulto , Idoso , SARS-CoV-2/isolamento & purificação , Expiração , Aldeídos/análise , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos
14.
J Clin Med ; 13(12)2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38929901

RESUMO

Background: Disorders of mucociliary clearance, such as cystic fibrosis (CF), primary ciliary dyskinesia (PCD) and bronchiectasis of unknown origin, are characterised by periods with increased respiratory symptoms, referred to as pulmonary exacerbations. These exacerbations are hard to predict and associated with lung function decline and the loss of quality of life. To optimise treatment and preserve lung function, there is a need for non-invasive and reliable methods of detection. Breath analysis might be such a method. Methods: We systematically reviewed the existing literature on breath analysis to detect pulmonary exacerbations in mucociliary clearance disorders. Extracted data included the study design, technique of measurement, definition of an exacerbation, identified compounds and diagnostic accuracy. Results: Out of 244 identified articles, 18 were included in the review. All studies included patients with CF and two also with PCD. Age and the definition of exacerbation differed between the studies. There were five that measured volatile organic compounds (VOCs) in exhaled breath using gas chromatography with mass spectrometry, two using an electronic nose and eleven measured organic compounds in exhaled breath condensate. Most studies showed a significant correlation between pulmonary exacerbations and one or multiple compounds, mainly hydrocarbons and cytokines, but the validation of these results in other studies was lacking. Conclusions: The detection of pulmonary exacerbations by the analysis of compounds in exhaled breath seems possible but is not near clinical application due to major differences in results, study design and the definition of an exacerbation. There is a need for larger studies, with a longitudinal design, international accepted definition of an exacerbation and validation of the results in independent cohorts.

15.
J Breath Res ; 18(4)2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38876091

RESUMO

The Peppermint Initiative, established within the International Association of Breath Research, introduced the peppermint protocol, a breath analysis benchmarking effort designed to address the lack of inter-comparability of outcomes across different breath sampling techniques and analytical platforms. Benchmarking with gas chromatography-ion mobility spectrometry (GC-IMS) using peppermint has been previously reported however, coupling micro-thermal desorption (µTD) to GC-IMS has not yet, been benchmarked for breath analysis. To benchmarkµTD-GC-IMS for breath analysis using the peppermint protocol. Ten healthy participants (4 males and 6 females, aged 20-73 years), were enrolled to give six breath samples into Nalophan bags via a modified peppermint protocol. Breath sampling after peppermint ingestion occurred over 6 h att= 60, 120, 200, 280, and 360 min. The breath samples (120 cm3) were pre-concentrated in theµTD before being transferred into the GC-IMS for detection. Data was processed using VOCal, including background subtractions, peak volume measurements, and room air assessment. During peppermint washout, eucalyptol showed the highest change in concentration levels, followed byα-pinene andß-pinene. The reproducibility of the technique for breath analysis was demonstrated by constructing logarithmic washout curves, with the average linearity coefficient ofR2= 0.99. The time to baseline (benchmark) value for the eucalyptol washout was 1111 min (95% CI: 529-1693 min), obtained by extrapolating the average logarithmic washout curve. The study demonstrated thatµTD-GC-IMS is reproducible and suitable technique for breath analysis, with benchmark values for eucalyptol comparable to the gold standard GC-MS.


Assuntos
Benchmarking , Testes Respiratórios , Mentha piperita , Humanos , Testes Respiratórios/métodos , Testes Respiratórios/instrumentação , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Espectrometria de Mobilidade Iônica/métodos , Espectrometria de Mobilidade Iônica/normas , Adulto Jovem , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cromatografia Gasosa/métodos , Cromatografia Gasosa/instrumentação , Cromatografia Gasosa/normas
16.
Diagn Microbiol Infect Dis ; 109(3): 116309, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38692202

RESUMO

BACKGROUND: The COVID-19 pandemic had profound global impacts on daily lives, economic stability, and healthcare systems. Diagnosis of COVID-19 infection via RT-PCR was crucial in reducing spread of disease and informing treatment management. While RT-PCR is a key diagnostic test, there is room for improvement in the development of diagnostic criteria. Identification of volatile organic compounds (VOCs) in exhaled breath provides a fast, reliable, and economically favorable alternative for disease detection. METHODS: This meta-analysis analyzed the diagnostic performance of VOC-based breath analysis in detection of COVID-19 infection. A systematic review of twenty-nine papers using the grading criteria from Newcastle-Ottawa Scale (NOS) and PRISMA guidelines was conducted. RESULTS: The cumulative results showed a sensitivity of 0.92 (95 % CI, 90 %-95 %) and a specificity of 0.90 (95 % CI 87 %-93 %). Subgroup analysis by variant demonstrated strong sensitivity to the original strain compared to the Omicron and Delta variant in detection of SARS-CoV-2 infection. An additional subgroup analysis of detection methods showed eNose technology had the highest sensitivity when compared to GC-MS, GC-IMS, and high sensitivity-MS. CONCLUSION: Overall, these results support the use of breath analysis as a new detection method of COVID-19 infection.


Assuntos
Testes Respiratórios , COVID-19 , SARS-CoV-2 , Sensibilidade e Especificidade , Compostos Orgânicos Voláteis , Compostos Orgânicos Voláteis/análise , Humanos , COVID-19/diagnóstico , Testes Respiratórios/métodos , SARS-CoV-2/isolamento & purificação , Teste para COVID-19/métodos , Cromatografia Gasosa-Espectrometria de Massas
17.
Spectrochim Acta A Mol Biomol Spectrosc ; 318: 124473, 2024 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-38795528

RESUMO

Infrared spectroscopy appears to be a promising analytical method for the metabolic analysis of breath. However, due to the presence of trace amounts in exhaled breath, the absorption strength of the metabolites remains extremely low. In such low detection limits, the nonlinear detection sensitivity of the infrared detector and electronic noise strongly modify the baseline of the acquired infrared spectra of breath. Fitting the reference molecular spectra with the baseline-modified spectral features of breath metabolites does not provide accurate identification. Therefore, baseline correction of the acquired infrared spectra of breath is the primary requirement for the success of breath-based infrared diagnosis. A selective spectral region-based, simple baseline correction method is proposed for the infrared spectroscopy of breath.


Assuntos
Testes Respiratórios , Expiração , Espectrofotometria Infravermelho , Testes Respiratórios/métodos , Humanos , Espectrofotometria Infravermelho/métodos , Expiração/fisiologia , Masculino , Adulto , Feminino
18.
J Breath Res ; 18(3)2024 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-38718786

RESUMO

Exhaled breath analysis has emerged as a non-invasive and promising method for early detection of lung cancer, offering a novel approach for diagnosis through the identification of specific biomarkers present in a patient's breath. For this longitudinal study, 29 treatment-naive patients with lung cancer were evaluated before and after surgery. Secondary electrospray ionization high-resolution mass spectrometry was used for exhaled breath analysis. Volatile organic compounds with absolute log2fold change ⩾1 andq-values ⩾ 0.71 were selected as potentially relevant. Exhaled breath analysis resulted in a total of 3482 features. 515 features showed a substantial difference before and after surgery. The small sample size generated a false positive rate of 0.71, therefore, around 154 of these 515 features were expected to be true changes. Biological identification of the features with the highest consistency (m/z-242.18428 andm/z-117.0539) revealed to potentially be 3-Oxotetradecanoic acid and Indole, respectively. Principal component analysis revealed a primary cluster of patients with a recurrent lung cancer, which remained undetected in the initial diagnostic and surgical procedures. The change of exhaled breath patterns after surgery in lung cancer emphasizes the potential for lung cancer screening and detection.


Assuntos
Testes Respiratórios , Expiração , Neoplasias Pulmonares , Compostos Orgânicos Voláteis , Humanos , Testes Respiratórios/métodos , Neoplasias Pulmonares/cirurgia , Masculino , Feminino , Estudos Longitudinais , Idoso , Pessoa de Meia-Idade , Compostos Orgânicos Voláteis/análise , Biomarcadores Tumorais/análise
19.
Front Endocrinol (Lausanne) ; 15: 1360989, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38752172

RESUMO

Purpose: This feasibility study aimed to investigate the use of exhaled breath analysis to capture and quantify relative changes of metabolites during resolution of acute diabetic ketoacidosis under insulin and rehydration therapy. Methods: Breath analysis was conducted on 30 patients of which 5 with DKA. They inflated Nalophan bags, and their metabolic content was subsequently interrogated by secondary electrospray ionization high-resolution mass spectrometry (SESI-HRMS). Results: SESI-HRMS analysis showed that acetone, pyruvate, and acetoacetate, which are well known to be altered in DKA, were readily detectable in breath of participants with DKA. In addition, a total of 665 mass spectral features were found to significantly correlate with base excess and prompt metabolic trajectories toward an in-control state as they progress toward homeostasis. Conclusion: This study provides proof-of-principle for using exhaled breath analysis in a real ICU setting for DKA monitoring. This non-invasive new technology provides new insights and a more comprehensive overview of the effect of insulin and rehydration during DKA treatment.


Assuntos
Testes Respiratórios , Cetoacidose Diabética , Insulina , Humanos , Cetoacidose Diabética/metabolismo , Testes Respiratórios/métodos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Insulina/metabolismo , Estudos de Viabilidade , Hidratação/métodos , Idoso , Biomarcadores/metabolismo , Biomarcadores/análise , Espectrometria de Massas por Ionização por Electrospray/métodos
20.
Clin Chim Acta ; 560: 119733, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38777246

RESUMO

BACKGROUND: Proton-transfer reaction time-of-flight mass spectrometry (PTR-TOF-MS) is a promising tool for a rapid online determination of exhaled volatile organic compounds (eVOCs) profiles in patients with cystic fibrosis (CF). OBJECTIVE: To detect VOC breath signatures specific to adult patients with CF compared with controls using PTR-TOF-MS. METHODS: 102 CF patients (54 M/48, mean age 25.6 ± 7.8 yrs) and 97 healthy controls (56 M/41F, mean age 25.8 ± 6.0 yrs) were examined. Samples from normal quiet breathing and forced expiratory maneuvers were analyzed with PTR-TOF-MS (Ionicon, Austria) to obtain VOC profiles listed as ions at various mass-to-charge ratios (m/z). RESULTS: PTR-TOF-MS analysis was able to detect 167 features in exhaled breath from CF patients and healthy controls. According to cluster analysis and LASSO regression, patients with CF and controls were separated. The most significant VOCs for CF were indole, phenol, dimethyl sulfide, and not indicated: m/z = 297.0720 ([C12H13N2O7 and C17H13O5]H + ), m/z = 281.0534 ([C19H7NO2, C12H11NO7 and C16H9O5]H + ) during five-fold cross-validation both in forced expiratory maneuver and in normal quiet breathing. CONCLUSION: PTR-TOF-MS is a promising method for determining the molecular composition of exhaled air specific to CF.


Assuntos
Testes Respiratórios , Fibrose Cística , Espectrometria de Massas , Compostos Orgânicos Voláteis , Humanos , Fibrose Cística/metabolismo , Fibrose Cística/diagnóstico , Testes Respiratórios/métodos , Adulto , Feminino , Compostos Orgânicos Voláteis/análise , Masculino , Expiração , Prótons , Adulto Jovem , Fatores de Tempo , Estudos de Casos e Controles
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...