Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 461
Filtrar
1.
BMC Public Health ; 24(1): 2188, 2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39135026

RESUMO

BACKGROUND: Population surveys are crucial for public policy planning and provide valuable representative data. In the health sector studies to identify and assess the prevalence of Arterial Hypertension (AH), a chronic non-communicable disease (NCD), along with its associated risk factors have been conducted. OBJECTIVES: This study aims to assess the effectiveness of a population health survey in estimating the prevalence of arterial hypertension (AH) in the Sorocaba municipality between August 2021 and June 2023. METHODS: The analyzed performance indicator is the precision (design effect - deff) of AH prevalence in adults (≥ 18 years) and their exposure to primary risk factors. The total sample included 1,080 individuals from the urban area, deemed sufficient to estimate a deff of 1.5. This cluster-based study utilized census sectors as clusters, with data collected through household interviews, standardized questionnaires, and measurements of blood pressure and biometric parameters. The deff calculation formula used was weighted variance / raw variance. The Research Ethics Committee approved this study, with registration CAAE 30538520-1-0000-5373. RESULTS: The deff values ranged from 0.44 for chronic obstructive pulmonary disease to 1.63 for asthma, with a deff of 1.00 for AH prevalence. CONCLUSION: The study demonstrated good precision in its results, with high receptivity and cooperation from participants. The cost-effectiveness of the research deemed appropriate. The technique of selecting households within clusters (census sectors) based on detailed mapping and demographic data from the Instituto Brasileiro de Geografia e Estatística (IBGE) proved to be practical and efficient, suitable for replication in other municipalities and for studying other NCDs.


Assuntos
Inquéritos Epidemiológicos , Hipertensão , Humanos , Hipertensão/epidemiologia , Hipertensão/diagnóstico , Prevalência , Adulto , Masculino , Pessoa de Meia-Idade , Feminino , Idoso , Adolescente , Adulto Jovem , Fatores de Risco , Brasil/epidemiologia
2.
J Otolaryngol Head Neck Surg ; 53: 19160216241250353, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39109789

RESUMO

BACKGROUND: Vestibular Activities and Participation Measure (VAP) subscales assess the effect of vestibular disorders on activity and participation. This study aimed to perform the cross-cultural adaptation and assess the validity, internal consistency, reliability, and measurement error of the Brazilian version of VAP subscales. METHODS: The cross-cultural adaptation followed the translation, synthesis, back-translation, review by a committee of experts, and pretesting phases. Structural validity was assessed using exploratory factor analysis (EFA) and confirmatory factor analysis (CFA), while Spearman's correlation between VAP subscales and the Dizziness Handicap Inventory (DHI) was used to assess construct validity. Cronbach's alpha measured internal consistency. Intraclass correlation coefficient (ICC) assessed intra- and inter-rater reliability, and measurement error was calculated by using the standard error of measurement (SEM) and minimal detectable change (MDC). RESULTS: Additional information was included in the Brazilian version of the Vestibular Activities and Participation measure (VAP-BR) after approval by one of the developers of the instrument to improve the understanding among individuals. One factor was found in the EFA for each subscale with 50% explained variance. Regarding CFA, the subscales 1 (S1) and 2 (S2) presented, respectively, adequate model fit indices (ie, comparative fit index of 0.99 and 0.97, and standardized root mean square residual of 0.04 for both subscales), but a very low factor load in item 6 of S1 (0.08). Chronbach's alpha was 0.80 (S1) and 0.82 (S2). For intra-rater assessment, the S1 and S2 presented an ICC of 0.87 and 0.90, SEM of 0.01 and 1.16, and MDC of 0.39 and 0.46, respectively. When assessed by 2 different raters, SEM values were 1.03 and 1.53, and MDC values were 2.85 and 4.23 for S1 and S2, respectively; both subscales showed an ICC of 0.92. Correlations between DHI and VAP subscales presented coefficients above 0.57. CONCLUSION: The Brazilian version of VAP subscales presents good measurement properties and may assist health professionals in identifying activity limitations and participation restrictions in individuals with vestibular disorders.


Assuntos
Comparação Transcultural , Traduções , Doenças Vestibulares , Humanos , Brasil , Reprodutibilidade dos Testes , Doenças Vestibulares/diagnóstico , Doenças Vestibulares/fisiopatologia , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Inquéritos e Questionários/normas , Psicometria , Avaliação da Deficiência , Análise Fatorial , Idoso
3.
Biomedica ; 44(Sp. 1): 160-170, 2024 05 31.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-39079137

RESUMO

INTRODUCTION: Choric obstructive pulmonary disease (COPD) is the third mortality cause in the world, and the development of useful diagnostic tools is necessary to improve timely diagnostic rates in primary care settings. OBJECTIVE: To develop a web application displaying spirometric and clinical information - including respiratory symptoms and risk factors- to facilitate a COPD diagnosis. MATERIALS AND METHODS: In this cross-sectional study, an expert consensus was carried out with three specialists using the Delphi method to choose the relevant variables for COPD diagnosis. We developed a Python-based web application to diagnose COPD, displaying the clinical variables deemed relevant by the experts along the spirometric curve. RESULTS: Twenty-six clinical variables were included in the web application for the diagnosis of COPD. A fourth expert used the web application to classify a cohort of 695 patients who had undergone spirometry in a third-level centre and had answered at least one of five questionnaires for COPD screening. Out of the 695 subjects, 34% had COPD, according to the expert that diagnosed them using the web application. Only 42% of the patients in the COPD group had received a previous COPD diagnosis and 19% of the patients in the no COPD group had been misdiagnosed with the disease. CONCLUSION: We developed a web application that displays demographic and clinical information, as well as spirometric data, to facilitate the process of diagnosing COPD in primary care settings.


Introducción. La enfermedad pulmonar obstructiva crónica (EPOC) es la tercera causa de mortalidad en el mundo y es necesario el desarrollo de herramientas diagnósticas útiles para mejorar las tasas de diagnóstico oportuno en los entornos de atención primaria. Objetivo. Desarrollar una aplicación web que muestre la información clínica y de la espirometría ­incluyendo síntomas respiratorios y factores de riesgo­ para facilitar el diagnóstico de la EPOC. Materiales y métodos. En este estudio transversal se realizó un consenso de expertos con tres especialistas usando el método Delphi para elegir las variables relevantes para el diagnóstico de EPOC. Se desarrolló una aplicación web basada en Python que muestra la información clínica relevante según los expertos, junto con la curva y los datos de la espirometría para el diagnóstico de la EPOC. Resultados. Se incluyeron 26 variables clínicas para el diagnóstico de la EPOC. Un cuarto experto utilizó la aplicación web para clasificar una cohorte de 695 pacientes a los que se les había realizado una espirometría en un centro de tercer nivel y que habían contestado al menos uno de los cinco cuestionarios para la detección de la EPOC. De los 695 sujetos, el 34 % tenían EPOC según el experto que les diagnosticó usando la aplicación web. Sólo el 42 % de los pacientes del grupo con EPOC había recibido un diagnóstico previo de la enfermedad y el 19 % de los pacientes del grupo sin EPOC había sido diagnosticado erróneamente con la enfermedad. Conclusión. Se desarrolló una aplicación web que muestra información demográfica y clínica, así como datos espirométricos, para facilitar el proceso de diagnóstico de la EPOC en entornos de atención primaria.


Assuntos
Internet , Atenção Primária à Saúde , Doença Pulmonar Obstrutiva Crônica , Espirometria , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Humanos , Estudos Transversais , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Técnica Delphi
4.
J World Fed Orthod ; 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38825421

RESUMO

BACKGROUND: As artificial intelligence within digital processes continues to advance and replace conventional manual workflows, it is crucial that digital data are consistent with analog data. The aim was to evaluate the validity and time efficiency of digital cast analysis on digital models in comparison with the manual, gold standard, cast analysis on plaster models. METHODS: Cast analysis was performed on 30 patients in three various methods: manually measured variables on plaster models (MP), manually measured variables on digital three-dimensional models (MD), and automatically measured variables on digital three-dimensional models (AD) on digital models. Digital cast analysis was performed in CS Model+. Analyses included metrical and categorical variables and the required work time. Measurements in MD and AD were validated to MP. Validity of the metrical variables was analyzed with Bland-Altman, Dahlberg's formula, and paired sample t test. Categorical variables were validated by Cohen's Kappa. Work time was analyzed with Wilcoxon signed-rank test. RESULTS: Metrical variables had measurement errors ranging 0.4 to 1.4 mm between MP-MD, and 0.6 to 3.2 mm between MP-AD. Observations of categorical variables had a moderate to strong (0.65 to 0.9) level of agreement between MP-MD, and a weak to moderate (0.4 to 0.68) level of agreement between MP-AD. Data for dental stage, vertical, and transversal relation was not provided in AD. Cast analysis was performed quicker digitally, P ≤ 0.05. CONCLUSIONS: Digital cast analysis is consistent with manual cast analysis for metrical variables. Analyses of categorical variables show a weak level of agreement with automatic digital analysis, such as space conditions and midline assessments. Digital cast analysis optimizes time compared with manual cast analysis, with automatic analysis being the fastest.

5.
Hip Pelvis ; 36(2): 129-134, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38825822

RESUMO

Purpose: Preoperative planning has become essential in performance of total hip arthroplasty (THA). However, data regarding the effect of the planner's experience on the accuracy of digital preoperative planning is limited. The objective of this study was to assess the accuracy of digital templating in THA based on the surgeon's experience. Materials and Methods: A retrospective study was conducted. An analysis of 98 anteroposterior pelvic radiographs, which were individually templated by four surgeons (two hip surgeons and two orthopaedic residents) using TraumaCad® digital planning, was performed. A comparison of preoperatively planned sizes with implanted sizes was performed to evaluate the accuracy of predicting component size. The results of preoperative planning performed by hip surgeons and orthopaedic residents were compared for testing of the planner's experience. Results: Femoral stem was precisely predicted in 32.4% of cases, acetabular component in 40.3%, and femoral offset in 76.7%. Prediction of cup size showed greater accuracy than femoral size among all observers. No differences in any variable were observed among the four groups (acetabular cup P=0.07, femoral stem P=0.82, femoral offset P=0.06). All measurements showed good reliability (intraclass correlation coefficient [ICC] acetabular cup: 0.76, ICC femoral stem: 0.79). Conclusion: The results of this study might suggest that even though a surgeon's experience supports improved precision during the planning stage, it should not be restricted only to surgeons with a high level of experience. We consider preoperative planning an essential part of the surgery, which should be included in training for orthopaedics residents.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38878087

RESUMO

Hypertension, which stands as a leading global health challenge, demands a dynamic approach for its effective management. The traditional methods of managing hypertension, centered on periodic clinic visits for blood pressure measurement and pharmacological interventions, are increasingly being complemented and enhanced by digital technologies. The integration of wearable devices, mobile applications, personalized treatments, and telehealth solutions into healthcare system is reshaping traditional hypertension care. Digitalization of hypertension management extends to population health, in addition to individual patient benefits, aimed at preventing and controlling hypertension on a broader scale. However, this digital revolution in hypertension management brings forth challenges related to data security, data accuracy, equitable access, and standardization of devices by international regulatory agencies. Addressing these issues is equally important to ensure that the benefits of digital technologies are accessible to everyone, irrespective of socio-economic factors. This paper concludes with a forward-looking perspectives, emphasizing the potential of digitalization to modify the landscape of hypertension management.

8.
BMC Oral Health ; 24(1): 736, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38926728

RESUMO

AIM: The study was performed to compare the mandibular resection guide with a directional guidance slot with the conventional guide regarding three-dimensional positional accuracy. MATERIALS AND METHODS: Twenty-six patients with lateral segmental mandibular defects were selected, and randomly allocated into two groups. All defects were managed with preoperative virtual surgical planning. Resection in the test group was conducted using a resection guide with a directional guidance slot, while a conventional resection guide design was utilized in the control group. The linear and angular deviation of the osteotomy planes was analyzed for both groups, along with the accuracy of the insertion of the reconstruction bone block in the resected defect. Data were documented, absolute deviation was calculated, statistical analysis was performed and significance was set at the 5% level. RESULTS: The cases conducted with a directional guidance templet reported a statistically significant difference when compared to the conventional edge-cutting guide regarding the linear and angular spatial osteotomy plane position (P < 0.001). The defect span analysis reported excellent levels of agreement in both groups (ICC = 1.00, ICC = 0.995), however, the difference between the groups was statistically significant (P < 0.001). CONCLUSION: The study demonstrated the enhanced positional accuracy of the resection plane and reconstruction block placement when a directional slot is incorporated in the computer-generated resection guide.


Assuntos
Mandíbula , Cirurgia Assistida por Computador , Humanos , Feminino , Masculino , Cirurgia Assistida por Computador/métodos , Mandíbula/cirurgia , Adulto , Imageamento Tridimensional/métodos , Osteotomia/métodos , Osteotomia/instrumentação , Pessoa de Meia-Idade
9.
Am J Epidemiol ; 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38775290

RESUMO

Electronic medical records (EMR) are important for rapidly compiling information to determine disease characteristics (e.g., symptoms) and risk factors (e.g., underlying comorbidities, medications) for disease-related outcomes. To assess EMR data accuracy, agreement between EMR abstractions and patient interviews was evaluated. Symptoms, medical history, and medication usage among COVID-19 patients collected from EMR and patient interviews were compared using overall agreement (same answer in EMR and interview), reported agreement (yes answer in both EMR and interview among those who reported yes in either), and Kappa statistics. Overall, patients reported more symptoms in interviews than in EMR abstractions. Overall agreement was high (≥50% for 20/23 symptoms), but only subjective fever and dyspnea had reported agreement of ≥50%. Kappa statistics for symptoms were generally low. Reported medical conditions had greater agreement with all condition categories (10/10) having ≥50% overall agreement and half (5/10) having ≥50% reported agreement. More non-prescription medications were reported in interviews than in EMR abstractions leading to low reported agreement (28%). Discordance was observed for symptoms, medical history, and medication usage between EMR abstractions and patient interviews. Investigations utilizing EMR to describe clinical characteristics and identify risk factors should consider the potential for incomplete data, particularly for symptoms and medications.

10.
J Imaging ; 10(5)2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38786573

RESUMO

Three-dimensional soft tissue simulation has become a popular tool in the process of virtual orthognathic surgery planning and patient-surgeon communication. To apply 3D soft tissue simulation software in routine clinical practice, both qualitative and quantitative validation of its accuracy are required. The objective of this study was to systematically review the literature on the accuracy of 3D soft tissue simulation in orthognathic surgery. The Web of Science, PubMed, Cochrane, and Embase databases were consulted for the literature search. The systematic review (SR) was conducted according to the PRISMA statement, and 40 articles fulfilled the inclusion and exclusion criteria. The Quadas-2 tool was used for the risk of bias assessment for selected studies. A mean error varying from 0.27 mm to 2.9 mm for 3D soft tissue simulations for the whole face was reported. In the studies evaluating 3D soft tissue simulation accuracy after a Le Fort I osteotomy only, the upper lip and paranasal regions were reported to have the largest error, while after an isolated bilateral sagittal split osteotomy, the largest error was reported for the lower lip and chin regions. In the studies evaluating simulation after bimaxillary osteotomy with or without genioplasty, the highest inaccuracy was reported at the level of the lips, predominantly the lower lip, chin, and, sometimes, the paranasal regions. Due to the variability in the study designs and analysis methods, a direct comparison was not possible. Therefore, based on the results of this SR, guidelines to systematize the workflow for evaluating the accuracy of 3D soft tissue simulations in orthognathic surgery in future studies are proposed.

11.
Front Med (Lausanne) ; 11: 1345983, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38808143

RESUMO

Aims: To assess the diagnostic accuracy and time impact of the 4AT scale in emergency department triage. Methods: A Prospective diagnostic accuracy study was carried out. People aged ≥65 years presenting to the emergency department from 1 November 2021 to 30 June 2022 were included. Nurses opportunistically screened eligible patients using the 4AT scale during triage according to the Manchester Triage System Francesc de Borja Hospital emergency department, Gandía (Spain). Accuracy was compared with medical diagnosis of delirium. Time (seconds) spent in triage with and without screening was assessed. Results: The study included 370 patients (55.1% men, mean age 81.8 years), of whom 58.4% (n = 216) were screened. A final diagnosis of delirium was made in 41.4% of those screened. The most frequently used presentational flow charts and discriminators were 'behaving strangely' (15%) and 'rapid onset' (33.3%). The highest accuracy was obtained for a score of 3 points or more (sensitivity 85.1%; specificity 66.9%; positive predictive value 52.8%; negative predictive value 71.7%). No significant differences were found in the time spent in triage according to the performance of screening. Conclusion: A score of 3 points or more on the 4AT scale enables rapid detection of delirium in emergency department triage, without consuming more time than conventional triage.

12.
JAMIA Open ; 7(2): ooae041, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38766645

RESUMO

Objective: To validate and demonstrate the clinical discovery utility of a novel patient-mediated, medical record collection and data extraction platform developed to improve access and utilization of real-world clinical data. Materials and Methods: Clinical variables were extracted from the medical records of 1011 consented patients with breast cancer. To validate the extracted data, case report forms completed using the structured data output of the platform were compared to manual chart review for 50 randomly-selected patients with metastatic breast cancer. To demonstrate the platform's clinical discovery utility, we identified 194 patients with early-stage clinical data who went on to develop distant metastases and utilized the platform-extracted data to assess associations between time to distant metastasis (TDM) and early-stage tumor histology, molecular type, and germline BRCA status. Results: The platform-extracted data for the validation cohort had 97.6% precision (91.98%-100% by variable type) and 81.48% recall (58.15%-95.00% by variable type) compared to manual chart review. In our discovery cohort, the shortest TDM was significantly associated with metaplastic (739.0 days) and inflammatory histologies (1005.8 days), HR-/HER2- molecular types (1187.4 days), and positive BRCA status (1042.5 days) as compared to other histologies, molecular types, and negative BRCA status, respectively. Multivariable analyses did not produce statistically significant results. Discussion: The precision and recall of platform-extracted clinical data are reported, although specificity could not be assessed. The data can generate clinically-relevant insights. Conclusion: The structured real-world data produced by a novel patient-mediated, medical record-extraction platform are reliable and can power clinical discovery.

13.
HNO ; 72(10): 711-719, 2024 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-38592481

RESUMO

BACKGROUND: Results of neurotological function diagnostics in the context of interdisciplinary vertigo assessment are usually formulated as free-text reports (FTR). These are often subject to high variability, which may lead to loss of information. The aim of the present study was to evaluate the completeness of structured reports (SR) and referrer satisfaction in the neurotological assessment of vertigo. MATERIALS AND METHODS: Neurotological function diagnostics performed as referrals (n = 88) were evaluated retrospectively. On the basis of the available raw data, SRs corresponding to FTRs from clinical routine were created by means of a specific SR template for neurotological function diagnostics. FTRs and SRs were evaluated for completeness and referring physician satisfaction (n = 8) using a visual analog scale (VAS) questionnaire. RESULTS: Compared to FTRs, SRs showed significantly increased overall completeness (73.7% vs. 51.7%, p < 0.001), especially in terms of patient history (92.5% vs. 66.7%, p < 0.001), description of previous findings (87.5% vs. 38%, p < 0.001), and neurotological (33.5% vs. 26.7%, p < 0.001) and audiometric function diagnostics (58% vs. 32.3%, p < 0.001). In addition, SR showed significantly increased referring physician satisfaction (VAS 8.8 vs. 4.9, p < 0.001). CONCLUSION: Neurotological SRs enable a significantly increased report completeness with higher referrer satisfaction in the context of interdisciplinary assessment of vertigo. Furthermore, SRs are particularly suitable for scientific data analysis, especially in the context of big data analyses.


Assuntos
Vertigem , Humanos , Vertigem/diagnóstico , Feminino , Masculino , Pessoa de Meia-Idade , Alemanha , Idoso , Adulto , Documentação/normas , Documentação/estatística & dados numéricos , Documentação/métodos , Neuro-Otologia , Encaminhamento e Consulta/estatística & dados numéricos , Estudos Retrospectivos , Idoso de 80 Anos ou mais
14.
Acta Neurochir (Wien) ; 166(1): 189, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653826

RESUMO

PURPOSE: Lumbar spinal stenosis (LSS) is a prevalent disorder, and surgery for LSS is a common procedure. Postoperative complications occur after any surgery and impose costs for society and costs and additional morbidity for patients. Since complications are relatively rare, medical registries of large populations may provide valuable knowledge. However, recording of complications in registries can be incomplete. To better estimate the true prevalence of complications after LSS surgery, we reviewed two different sources of data and recorded complications for a sample of Norwegian LSS patients. METHODS: 474 patients treated surgically for LSS during 2015 and 2016 at four hospitals reported to a national spine registry (NORspine). Postoperative complications were recorded by patients in NORspine, and we cross-referenced complications documented in NORspine with the patients´ electronic patient records (EPR) to re-test the complication rates. We performed descriptive statistics of complication rates using the two different data sources above, and analyzed the association between postoperative complications and clinical outcome with logistic regression. RESULTS: The mean (95%CI) patient age was 66.3 (65.3-67.2) years, and 254 (53.6%) were females. All patients were treated with decompression, and 51 (10.7%) received an additional fusion during the index surgery. Combining the two data sources, we found a total rate for postoperative complications of 22.4%, the NORspine registry reported a complication rate of 15.6%, and the EPR review resulted in a complication rate of 16.0%. However, the types of complications were inconsistent across the two data sources. According to NORspine, the frequency of reoperation within 90 days was 0.9% and according to EPR 3.4%. The rates of wound infection were for NORspine 3.1% and EPR review 2.1%. There was no association between postoperative complication and patient reported outcome. CONCLUSION: Postoperative complications occurred in 22% of LSS patients. The frequency of different postoperative complications differed between the two data sources.


Assuntos
Descompressão Cirúrgica , Vértebras Lombares , Complicações Pós-Operatórias , Sistema de Registros , Fusão Vertebral , Estenose Espinal , Humanos , Estenose Espinal/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Feminino , Masculino , Idoso , Vértebras Lombares/cirurgia , Descompressão Cirúrgica/efeitos adversos , Descompressão Cirúrgica/métodos , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos , Noruega/epidemiologia , Pessoa de Meia-Idade , Fonte de Informação
15.
Acta Otolaryngol ; 144(3): 193-197, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38662877

RESUMO

BACKGROUND: Non-Echo-Planar Diffusion Weighed Magnetic Resonance Imaging (non-EPI DW MRI) plays a role in the planning of cholesteatoma surgery. OBJECTIVES: To outline the usage of Non-EPI DW MRI in cholesteatoma diagnostics and to determine its accuracy, using otosurgery diagnostics as reference standard. MATERIAL AND METHODS: A retrospective descriptive study. All subjects operated, with suspicion of cholesteatoma as indication, that had a preceding examination with non-EPI DW MRI, between October 2010 and March 2019. Calculating sensitivity, specificity, predicative values, and likelihood ratios, using non-EPI DW MRI as index test and diagnosis from otosurgery as reference standard. RESULTS: Fifty-two subject episodes were included. Non-EPI DW MRI had a sensitivity of 0.50, specificity of 0.75, positive and negative predictive values of 0.74 and 0.52 and, positive and negative likelihood ratios of 2.0 and 0.67 respectively. CONCLUSIONS AND SIGNIFICANCE: There is a clear annual trend with increased numbers of executed examinations during the study period. The diagnostic accuracy of non-EPI DW MRI does not reach acceptable levels in the existing everyday routine practice conditions. The accuracy of the examination increases when interpreted by an experienced radiologist and when using the definition of cholesteatoma recommended by EAONO/JOS.


Assuntos
Colesteatoma da Orelha Média , Humanos , Estudos Retrospectivos , Colesteatoma da Orelha Média/diagnóstico por imagem , Colesteatoma da Orelha Média/cirurgia , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Idoso , Sensibilidade e Especificidade , Adulto Jovem , Adolescente , Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos
16.
BMJ Open Qual ; 13(2)2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649198

RESUMO

Precise medical billing is essential for decreasing hospital liability, upholding environmental stewardship and ensuring fair costs for patients. We instituted a multifaceted approach to improve the billing accuracy of our robotic-assisted thoracic surgery programme by including an educational component, updating procedure cards and removing the auto-populating function of our electronic medical record. Overall, we saw significant improvements in both the number of inaccurate billing cases and, specifically, the number of cases that overcharged patients.


Assuntos
Registros Eletrônicos de Saúde , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/estatística & dados numéricos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/normas , Procedimentos Cirúrgicos Robóticos/economia , Registros Eletrônicos de Saúde/estatística & dados numéricos , Procedimentos Cirúrgicos Torácicos/métodos , Procedimentos Cirúrgicos Torácicos/economia , Procedimentos Cirúrgicos Torácicos/estatística & dados numéricos , Procedimentos Cirúrgicos Torácicos/normas
17.
J Prosthodont ; 33(6): 550-557, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38507280

RESUMO

PURPOSE: The aims of the present study were (a) to compare the scanning time and image count to complete optical scans of a typodont between augmented-reality-assisted intraoral scanning (ARIOS) and intraoral scanning (IOS); (b) to compare the accuracy of the digital casts derived from ARIOS and IOS; (c) to compare participant-related outcomes between ARIOS and IOS. MATERIALS AND METHODS: A multi-session within-subject experiment was conducted to compare ARIOS and IOS. Thirty-one dental students participated in the study. Following a trial session, each participant obtained optical scans under ARIOS and IOS conditions. The time required to complete the scan, and the number of images taken were recorded. Participant feedback was collected using entry, exit, and NASA-Task Load Index (TLX) surveys. The accuracy of the digital casts derived from the optical scans was measured in root mean square error (RMSE). RESULTS: The present study found a 6.8% increase in preference for ARIOS from entry to exit survey. Slightly more participants favored the ARIOS setup compared to IOS; 54.8% of participants favored ARIOS, 9.7% were indifferent, and 35.5% favored IOS. NASA-TLX subscale ratings were higher for IOS in general apart from mental demand. The accuracy of the digital casts between ARIOS and IOS was comparable in RMSE. CONCLUSION: ARIOS was advantageous compared to IOS in ergonomics, improved scanner tracking, and ease of scanner orientation. However additional trials, increased field of view, and better superimposition of scanning status to the target site were improvements desired by the study participants.


Assuntos
Realidade Aumentada , Estudo de Prova de Conceito , Humanos , Feminino , Modelos Dentários , Masculino , Desenho Assistido por Computador , Imageamento Tridimensional/métodos , Adulto Jovem , Estudantes de Odontologia , Adulto
18.
Gac Sanit ; 38: 102372, 2024 Mar 08.
Artigo em Espanhol | MEDLINE | ID: mdl-38460207

RESUMO

OBJECTIVE: To evaluate the health information system (HIS) of Mexico according to the information reported to the Organization for Economic Co-operation and Development (OECD). The ultimate goal is to identify the improvements that should be considered. METHOD: Health indicators published by the OECD (2017 to 2021) are analyzed according to 11 thematic groups. Coverage (quantity and type of indicators reported by thematic group) and quality of information were assessed, according to OECD guidelines. RESULTS: Mexico reported annually 14 of 378 indicators (3.7%), and discontinuously 204. In no group were all indicators reported annually, except for the two on COVID-19. Three out of 88 were reported annually on use of services; and none on health status, quality of care and pharmaceutical market. Twelve indicators (5.5% of those reported by Mexico, 3.2% of the full OECD set) had optimal quality and annual reporting. 57.7% of the reported indicators had at least one quality defect. CONCLUSIONS: Within the framework of the standards set by the OECD, of which Mexico is a member, the Mexican HIS presents significant deficits in coverage and quality of information. These results should be considered to implement improvement initiatives.

20.
BMC Cancer ; 24(1): 329, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38468209

RESUMO

BACKGROUND: Population-based cancer quality registries are of great importance for the improvement of cancer care. However, little is known about the quality of recurrence data in cancer quality registries. The aim of this study was to evaluate data quality in the regional Breast Cancer Quality Registry of Central Sweden, with emphasis on the validity of recorded information on recurrence. METHODS: Validation by re-abstraction was performed on a random sample of 800 women with primary invasive breast cancer stage I-III diagnosed between 1993 and 2010, of which 400 had at least one registered recurrence and 400 had no registered recurrence. Registry data were compared with data from medical records. Exact agreement, correlation and kappa values, sensitivity and specificity were calculated. RESULTS: Seven hundred forty-seven women (93%) were available for analysis. Exact agreement was high for diagnostics, tumor characteristics, surgery, and adjuvant oncological treatment (90% or more for most variables). The registry's sensitivity was low for regional recurrence (47%), but higher for local and distant recurrence (80% and 75%), whereas specificity was overall high (≥ 95%). Combining all recurrence categories irrespective of localization improved sensitivity to 90% with a specificity of 91%. In 87% of women, the date of first recurrence according to medical records fell within ± 90 days of the date recorded in the registry. CONCLUSIONS: While the quality of data in the regional Breast Cancer Quality Registry was generally high, data accuracy on recurrences was lower. The overall precision of identifying any recurrence, irrespective of localization, was high. However, the accuracy of classification of recurrences (local, regional or distant) was lower, with evidence of underreporting for each of the recurrence categories. Given the importance of recurrence-related outcomes in the assessment of quality of care, efforts should be made to improve the reporting of recurrences.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/epidemiologia , Neoplasias da Mama/terapia , Confiabilidade dos Dados , Suécia/epidemiologia , Sensibilidade e Especificidade , Sistema de Registros , Recidiva Local de Neoplasia/epidemiologia , Recidiva Local de Neoplasia/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...