Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 13.236
Filtrar
1.
Cureus ; 16(8): e68136, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39350800

RESUMO

Persistent left superior vena cava (PLSVC) is a relatively rare anatomical anomaly, with a higher prevalence in those with congenital heart defects. While typically asymptomatic, its presence can complicate certain medical procedures, particularly cardiac interventions, such as the implantation of cardiac resynchronization therapy (CRT) devices, due to acute angulation. In this report, we discuss the challenges posed by the unanticipated presence of PLSVC during CRT device implantation and describe the technique used for lead placement using Judkins Right catheter for support, placing coronary wire, and later placing the left ventricle (LV) lead with the help of buddy wire technique, resulting in successful insertion of all three CRT leads despite the anatomical challenges.

2.
Reprod Med Biol ; 23(1): e12612, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39351129

RESUMO

Purpose: To investigate the usefulness of an original dual artificial intelligence (AI) system, in which the first AI system eliminates the background of sliced tomographic blastocyst images, then the second AI system predicts implantation success using three-dimensional (3D) reconstructed images of the sequential images and conventional embryo evaluation parameters (CEE) such as maternal age. Methods: Patients (from June 2022 to July 2023) could opt out and there was additional information on the Web site of the clinic. Implantation and non-implantation cases numbered 458 and 519, respectively. A total of 10 747 tomographic images of the blastocyst in a time-lapse incubator system with the CEE were obtained. Results: The statistic values by the dual AI system were 0.774 ± 0.033 (mean ± standard error) for area under the characteristic curve, 0.727 for sensitivity, 0.719 for specificity, 0.727 for predictive value of positive test, 0.719 predictive value of negative test, and 0.723 for accuracy, respectively. Conclusions: The usefulness of the dual AI system in predicting implantation of blastocyst in handling 3D data with conventional embryo evaluation information was demonstrated. This system may be a feasible option in clinical practice.

3.
World Neurosurg ; 2024 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-39353508

RESUMO

OBJECTIVE: Dorsal root ganglion (DRG) stimulator leads were designed to be placed percutaneously, yet open surgical placement via laminectomy is an option. We present the largest series to date of surgically-placed DRG stimulators and the first series where open surgical implantation was the chosen technique and not a salvage procedure. METHODS: A retrospective review of a prospective database of DRG implants identified 17 patients who had open lumbosacral DRG lead placement performed by a single surgeon (NDT) between October 2021 and April 2023. Descriptive statistics, fluoroscopy exposure times, and complications were reported. The window of data collection was 1 month pre-operatively to 12 months post-operatively. Phone interviews were conducted to collect information on pain outcomes and patient satisfaction. RESULTS: We identified 17 patients (12 women, 5 men) who had lumbosacral DRG placement. Phone interviews were conducted for 10/17 patients, with mean follow-up of 11.9 months. 53% reduction in mean pain score was achieved (n=10, p<0.001). There were no infections, hematomas, or symptomatic lead migrations. 1/17 experienced a superficial dehiscence and 2/17 had an intra-operative repairable durotomy with no post-operative sequelae. Mean fluoroscopy time per lead was 15.4±9.9s (n=10). CONCLUSION: Open DRG lead placement via laminotomy/laminectomy is reported as a salvage procedure but may have comparable safety and efficacy profile to percutaneous implantation when utilized as the primary implantation method. Before establishing open DRG as an alternative permanent implantation method, more studies are needed to determine whether such benefits as less migration outweigh the risks of a more invasive implantation procedure.

4.
BMJ Case Rep ; 17(10)2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39353676

RESUMO

Bone cement implantation syndrome (BCIS) is a potentially serious complication after joint replacement surgery, resulting from bone marrow debris and cement embolisation, culminating in pulmonary and cardiovascular collapse. Echocardiography aids in diagnosis and management. We present a woman in her 80s with grade II BCIS. CT angiogram was inconclusive, but echocardiography revealed hyperechogenic material and right ventricular dysfunction, confirming the diagnosis. She received cardiovascular and respiratory support in a level II intensive care unit, showing full recovery of the right ventricle function when it was later reassessed. This potentially fatal condition is successfully managed if recognised early with adequate supportive care. Echocardiography might guide the diagnosis, consolidating supportive measures.


Assuntos
Cimentos Ósseos , Ecocardiografia , Humanos , Feminino , Cimentos Ósseos/efeitos adversos , Síndrome , Idoso de 80 Anos ou mais , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia , Complicações Pós-Operatórias/diagnóstico por imagem
5.
Arch Cardiovasc Dis ; 2024 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-39353805

RESUMO

Nowadays, valvular heart disease remains a significant challenge among cardiovascular diseases, affecting millions of people worldwide and exerting substantial pressure on healthcare systems. Within the spectrum of valvular heart disease, aortic stenosis is the most common valvular lesion in developed countries. Despite notable advances in understanding its pathophysiological processes, improved cardiovascular imaging techniques and expanding therapeutic options in recent years, there are still unmet needs and knowledge gaps regarding aortic stenosis pathophysiology, severity assessment, management and decision-making strategy. This review, prepared on behalf of the Heart Valve Council of the French Society of Cardiology, describes these gaps and future research perspectives to improve the outcome of patients with aortic stenosis.

6.
Front Cardiovasc Med ; 11: 1398114, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39355352

RESUMO

Aims: Patients with severe aortic stenosis (AS), low transvalvular flow (LF) and low gradient (LG) with normal ejection fraction (EF)-are referred to as paradoxical LF-LG AS (PLF-LG). PLF-LG patients develop more advanced heart failure symptoms and have a worse prognosis than patients with normal EF and high-gradient AS (NEF-HG). Despite its clinical relevance, the mechanisms underlying PLF-LG are still poorly understood. Methods: Left ventricular (LV) myocardial biopsies of PLF-LG (n = 5) and NEF-HG patients (n = 6), obtained during transcatheter aortic valve implantation, were analyzed by LC-MS/MS after sequential extraction of cellular and extracellular matrix (ECM) proteins using a three-step extraction method. Proteomic data are available via ProteomeXchange with identifier PXD055391. Results: 73 cellular proteins were differentially abundant between the 2 groups. Among these, a network of proteins related to muscle contraction and arrhythmogenic cardiomyopathy (e.g., cTnI, FKBP1A and CACNA2D1) was found in PLF-LG. Extracellularly, upregulated proteins in PLF-LG were related to ATP synthesis and oxidative phosphorylation (e.g., ATP5PF, COX5B and UQCRB). Interestingly, we observed a 1.3-fold increase in cyclophilin A (CyPA), proinflammatory cytokine, in the extracellular extracts of PLF-LG AS patients (p < 0.05). Consistently, immunohistochemical analysis confirmed its extracellular localization in PLF-LG AS LV sections along with an increase in its receptor, CD147, compared to the NEF-HG AS patients. Levels of core ECM proteins, namely collagens and proteoglycans, were comparable between groups. Conclusion: Our study pinpointed novel candidates and processes with potential relevance in the pathophysiology of PLF-LG. The role of CyPA in particular warrants further investigation.

7.
Pol Merkur Lekarski ; 52(4): 400-407, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39360719

RESUMO

OBJECTIVE: Aim: To assess, analyze and present early postoperative results of transcatheter aortic valve implantation in patients with aortic stenosis. PATIENTS AND METHODS: Materials and Methods: During the period from 2017 to 2023, we examined in total 77 patients with severe aortic stenosis and high risk of surgery who were eligible for the TAVI procedure at the "Heart Institute Ministry of Health of Ukraine". RESULTS: Results: Before implantation, the mean and maximum aortic valve gradients were 53.7±19.1 mm Hg and 90.1±28.8 mm Hg, respectively. The mean and maximum aortic valve gradients after implantation were 9.67±3.18 and 18.7±6.41, respectively (p<0.001). The calculated left ventricular ejection fraction was 57.5±8.22% before surgery and 58.8±7.91% after surgery (p=0.412). After the procedure, moderate (2) degree of paravalvular aortic regurgitation was observed in 2 patients and light degree - in 21 patients. Before surgery, mitral regurgitation of 2-3 degrees was observed in 15 patients, and only in two patients after TAVI The survival rate of our patients was 96.4% after 180 days of supervision. In-hospital and 30-day mortality was 1.8%, while 180-day mortality was 3.6%. No deterioration was observed in patients with moderate aortic regurgitation during echocardiographic studies performed at 1, 3 and 6 months after TAVI. CONCLUSION: Conclusions: TAVI is rapidly emerging as a life-saving alternative for patients who are inoperable or at high risk of surgery due to comorbidities. The selection of patients for TAVI is important to optimize procedural and long-term outcomes. It is important for cardiologists in our country to refer patients with severe aortic stenosis after diagnosis to centers that perform TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Idoso , Resultado do Tratamento , Ucrânia/epidemiologia , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Valva Aórtica/cirurgia , Taxa de Sobrevida
8.
Artigo em Inglês | MEDLINE | ID: mdl-39361225

RESUMO

INTRODUCTION: Transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR) are established interventions for alleviating symptoms and enhancing survival in individuals with severe aortic stenosis (AS). However, the long-term outcomes and incidence of reintervention associated with TAVI and SAVR remain uncertain. METHODS: We conducted a systematic review and meta-analysis to compare the incidence of reintervention in TAVI versus SAVR. PubMed, Embase, and Cochrane databases were searched for randomized controlled trials (RCTs). Risk ratios (RR) and 95% confidence intervals (CI) were pooled with a random-effects model. A p-value < 0.05 was considered statistically significant. RESULTS: Nine RCTs were included, with 5144 (50.9%) patients randomized to TAVI. Compared with SAVR, TAVI increased reinterventions (RR 1.89; 95% CI 1.29-2.76; p < 0.01) and the need for pacemakers (RR 1.91; 95% CI 1.49-2.45; p < 0.01). In addition, TAVI significantly reduced the incidence of new-onset atrial fibrillation (RR 0.43; 95% CI 0.32- 0.59; p < 0.01). There were no significant differences in all-cause mortality (RR 1.04; 95% CI 0.92-1.16; p = 0.55), cardiovascular mortality (RR 1.04; 95% CI 0.94-1.17; p = 0.44), stroke (RR 0.97; 95% CI 0.80-1.17; p = 0.76), endocarditis (RR 0.96; 95% CI 0.70-1.33; p = 0.82), and myocardial infarction (RR 1.06; 95% CI 0.79-1.41; p = 0.72) between groups. CONCLUSIONS: In patients with severe AS, TAVI significantly increased the incidence of reinterventions and the need for pacemakers as compared with SAVR.

9.
Artif Organs ; 2024 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-39361246

RESUMO

BACKGROUND: ShuttlePump is a novel total artificial heart (TAH) recently introduced to potentially overcome the limitations associated with the current state-of-the-art mechanical circulatory support devices intended for adults. In this study, we adapted the outflow cannulation of the previously established ShuttlePump TAH and evaluated the anatomical compatibility using the virtual implantation technique. METHODS: We retrospectively assessed the anatomical compatibility of the ShuttlePump using virtual implantation techniques within 3D-reconstructed anatomies of adult heart failure patients. Additionally, we examined the impact of outflow cannula modification on the hemocompatibility of the ShuttlePump through computational fluid dynamic simulations. RESULTS: A successful virtual implantation in 9/11 patients was achieved. However, in 2 patients, pump interaction with the thoracic cage was observed and considered unsuccessful virtual implantation. A strong correlation (r <-0.78) observed between the measured anatomical parameters and the ShuttlePump volume exceeding pericardium highlights the importance of these measurements apart from body surface area. The numerical simulation revealed that the angled outflow cannulation resulted in a maximum pressure drop of 1.8 mmHg higher than that of the straight outflow cannulation. With comparable hemolysis index, the shear stress thresholds of angled outflow differ marginally (<5%) from the established pump model. Similar washout behavior between the pump models indicate that the curvature did not introduce stagnation zone. CONCLUSION: This study demonstrates the anatomic compatibility of the ShuttlePump in patients with biventricular failure, which was achieved by optimizing the outflow cannulation without compromising hemocompatibility. Nevertheless, clinical validation is critical to ensure the clinical applicability of these findings.

10.
Indian Dermatol Online J ; 15(5): 812-816, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39359298

RESUMO

Background: Warts are benign epidermal proliferations, caused by infection of keratinocytes with human papillomavirus (HPV). Auto implantation and intralesional mumps, measles, and rubella (MMR) vaccine are novel methods of immunotherapy for treating periungual and palmoplantar warts. They act by stimulating the patient's immune system; this clears not only the local warts but also distant warts with lesser side effects. Objective: We conducted this study to compare the efficacy and safety of both methods in treating periungual and palmoplantar warts. Materials and Methods: A total of 160 patients were randomly allocated into two groups of 80 patients. Group A was treated with 0.3 mL of intralesional MMR vaccine at an interval of 3 weeks or for a maximum of three sittings, and Group B was treated with auto implantation. Results: At the end of therapy, the result was better in group A (MMR vaccine) as 86% of cases yielded an excellent response as compared to 71% in group B (auto implantation). The recurrence rate was 5% in group A and 4% in group B. There were no serious side effects in both groups with pain during injection (70%) in group A and swelling at the recipient site (8%) in group B being the most common side effect. Conclusion: Both MMR and auto implantation had significant response rates. But MMR was faster and better.

11.
JACC Case Rep ; 29(17): 102506, 2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-39359513

RESUMO

We present one of the inaugural transcatheter aortic valve implantation procedures using the latest Medtronic platform, Evolut FX+. Successful coronary angiography was achieved within 28 seconds and 1 minute 49 seconds for the left and right coronary arteries, respectively. Postoperative cardiac computed tomography scan demonstrated optimal commissural and diamond-coronary alignment.

12.
Cureus ; 16(9): e68449, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39360079

RESUMO

Recent advancements in assisted reproductive technology (ART) have enabled couples to achieve pregnancy, who were previously unable to conceive. However, recurrent implantation failure (RIF) remains a significant challenge. This case study exhibits the effective use of hysteroscopic-guided platelet-rich plasma (PRP) instillation in the treatment of a female patient aged 33 who was nulliparous and diagnosed with RIF and a thin endometrium, which resulted in primary infertility. The couple had a history of 10 years of infertility and had previously undergone ART procedures, including intrauterine insemination (IUI) and intracytoplasmic sperm injection (ICSI), which failed. The female partner was diagnosed with a thin endometrium (<7 mm) and underwent hysteroscopy, revealing no other significant intrauterine pathologies. Following hormonal treatment and ovum pick-up, hysteroscopic PRP was administered, resulting in improved endometrial thickness (ET) and successful embryo implantation, as evidenced by a positive serum ß-hCG level of 1470 mIU/mL. This case demonstrates the hysteroscopic injection of PRP's potential for increasing endometrial receptivity and enhancing ART outcomes in women with RIF due to thin endometrium, making it a promising alternative to conventional therapies.

13.
J Nephrol ; 2024 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-39356416

RESUMO

BACKGROUND: Pre-transplant procurement biopsy interpretation is challenging, also because of the low number of renal pathology experts. Artificial intelligence (AI) can assist by aiding pathologists with kidney donor biopsy assessment. Herein we present the "Galileo" AI tool, designed specifically to assist the on-call pathologist with interpreting pre-implantation kidney biopsies. METHODS: A multicenter cohort of whole slide images acquired from core-needle and wedge biopsies of the kidney was collected. A deep learning algorithm was trained to detect the main findings evaluated in the pre-implantation setting (normal glomeruli, globally sclerosed glomeruli, ischemic glomeruli, arterioles and arteries). The model obtained on the Aiforia Create platform was validated on an external dataset by three independent pathologists to evaluate the performance of the algorithm. RESULTS: Galileo demonstrated a precision, sensitivity, F1 score and total area error of 81.96%, 94.39%, 87.74%, 2.81% and 74.05%, 71.03%, 72.5%, 2% in the training and validation sets, respectively. Galileo was significantly faster than pathologists, requiring 2 min overall in the validation phase (vs 25, 22 and 31 min by 3 separate human readers, p < 0.001). Galileo-assisted detection of renal structures and quantitative information was directly integrated in the final report. CONCLUSIONS: The Galileo AI-assisted tool shows promise in speeding up pre-implantation kidney biopsy interpretation, as well as in reducing inter-observer variability. This tool may represent a starting point for further improvements based on hard endpoints such as graft survival.

14.
J Nanobiotechnology ; 22(1): 598, 2024 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-39363196

RESUMO

BACKGROUND: Surgeries for treating pelvic organ prolapse involving the utilization of synthetic mesh have been associated with complications such as mesh erosion, postoperative pain, and dyspareunia. This work aimed to reduce the surgical implantation-associated complications by nanofibrous membranes on the surface of the polypropylene mesh. The nanofiber of the nanofibrous membrane, which was fabricated by co-axial electrospinning, was composed of polyurethane as fiber core and gelatin as the fiber out layer. The biocompatibility of the modified mesh was evaluated in vitro by cell proliferation assay, immunofluorescence stain, hematoxylin-eosin (HE) staining, and mRNA sequencing. Polypropylene mesh and modified mesh were implanted in a rat pelvic organ prolapse model. Mesh-associated complications were documented. HE and Picro-Sirius red staining, immunohistochemistry, and western blotting were conducted to assess the interactions between the modified mesh and vaginal tissues. RESULTS: The modified mesh significantly enhanced the proliferation of fibroblasts and exerted a positive regulatory effect on the extracellular matrix anabolism in vitro. When evaluated in vivo, no instances of mesh exposure were observed in the modified mesh group. The modified mesh maintained a relatively stable histological position without penetrating the muscle layer or breaching the epidermis. The collagen content in the vaginal wall of rats with modified mesh was significantly higher, and the collagen I/III ratio was lower, indicating better tissue elasticity. The expression of metalloproteinase was decreased while the expression levels of tissue inhibitor of metalloproteinase were increased in the modified mesh group, suggesting an inhibition of collagen catabolism. The expression of TGF-ß1 and the phosphorylation levels of Smad3, p38 and ERK1/2 were significantly increased in the modified mesh group. NM significantly improved the biocompatibility of PP mesh, as evidenced by a reduction in macrophage count, decreased expression levels of TNF-α, and an increase in microvascular density. CONCLUSIONS: The nanofibrous membrane-coated PP mesh effectively reduced the surgical implantation complications by inhibiting the catabolism of collagen in tissues and improving the biocampibility of PP mesh. The incorporation of co-axial fibers composed of polyurethane and gelatin with polypropylene mesh holds promise for the development of enhanced surgical materials for pelvic organ prolapse in clinical applications.


Assuntos
Proliferação de Células , Nanofibras , Prolapso de Órgão Pélvico , Polipropilenos , Ratos Sprague-Dawley , Telas Cirúrgicas , Animais , Nanofibras/química , Feminino , Ratos , Polipropilenos/química , Prolapso de Órgão Pélvico/cirurgia , Vagina/cirurgia , Vagina/metabolismo , Fibroblastos/metabolismo , Complicações Pós-Operatórias , Poliuretanos/química , Materiais Biocompatíveis/química , Membranas Artificiais
15.
Open Heart ; 11(2)2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39353702

RESUMO

BACKGROUND: This present study aimed to investigate the impact of left atrial appendage (LAA) isolation on adverse clinical outcomes, with a further stratified analysis by biatrial (BA) and left atrial lesion sets, in patients with atrial fibrillation (AF) undergoing surgical ablation (SA) concurrent with mitral valve (MV) surgery. METHODS: We evaluated 875 patients (aged 65.1±12.0 years) who underwent SA of AF concomitant to MV surgery, excluding those with mechanical prostheses requiring lifelong anticoagulation, between 2005 and 2017 in five tertiary cardiac centres in South Korea. Of these, 458 had isolated the LAA, whereas the remainder (n=417) had the LAA preserved. Comparative risk of stroke, mortality and AF recurrence was assessed between the groups, considering death as a competing event. Inverse-probability treatment weighting was used for baseline adjustment. RESULTS: During the median follow-up of 57.4 months (IQR, 32.5-92.4 months), the adjusted risk of long-term stroke was significantly lower in the patients who underwent LAA isolation compared with those who preserved the LAA (subdistribution HR (SHR), 0.28; 95% CI 0.15 to 0.51; p<0.001). However, there were no significant differences in the adjusted risk of mortality (HR, 0.85; 95% CI 0.57 to 1.27; p=0.429) or AF recurrence (SHR, 0.92; 95% CI 0.78 to 1.08; p=0.291) between LAA isolation and preservation. In the subgroup of patients who underwent BA ablation, LAA isolation was associated with a lower long-term risk of stroke and AF recurrence (SHR, 0.77; 95% CI 0.61 to 0.94; p=0.029) compared with LAA preservation. CONCLUSIONS: Concomitant LAA isolation during SA of AF in patients undergoing MV surgery was associated with a significantly lower risk of long-term stroke, but no survival benefit was observed.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Pontuação de Propensão , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Apêndice Atrial/cirurgia , Masculino , Feminino , Idoso , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , República da Coreia/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Tempo , Fatores de Risco , Pessoa de Meia-Idade , Seguimentos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Medição de Risco/métodos , Valva Mitral/cirurgia
16.
bioRxiv ; 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-39372752

RESUMO

Cyclin-dependent kinases (CDK) are key regulatory enzymes that regulate proliferation dynamics and cell fate in response to extracellular inputs. It remains largely unknown how CDK activity fluctuates and influences cell commitment in vivo during early mammalian development. Here, we generated a transgenic mouse model expressing a CDK kinase translocation reporter (KTR) that enabled quantification of CDK activity in live single cells. By examining pre- and post-implantation mouse embryos at different stages, we observed a progressive decrease in CDK activity in cells from the trophectoderm (TE) prior to implantation. This drop correlated with the establishment of an FGF4-dependent signaling gradient through the embryonic-abembryonic axis. Furthermore, we showed that CDK activity levels do not determine cell fate decisions during pre-implantation development. Finally, we uncovered the existence of conserved regulatory mechanisms in mammals by revealing lineage-specific regulation of CDK activity in TE-like human cells.

17.
Heart Lung Circ ; 2024 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-39384516

RESUMO

AIM: Neutrophil-lymphocyte ratio (NLR) and platelet-lymphocyte ratio (PLR) are simple biomarkers that reflect systemic inflammation and are associated with adverse cardiovascular disease outcomes. The utility of NLR and PLR for risk prediction following transcatheter aortic valve implantation (TAVI) is not clear. METHOD: We retrospectively analysed a prospectively maintained database of patients who underwent TAVI at a tertiary hospital from 2009 to 2022. Baseline demographics, NLR, PLR and Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) scores were obtained. The 30-day and 1-year survival rates were analysed using a logistic regression model while overall survival was analysed using the Kaplan-Meier method. Predictors of survival were calculated using a Cox-hazards regression model and presented as odds ratio (OR) with 95% confidence interval (CI). RESULTS: Overall, 367 patients were included in this study (mean age 84 years, 51% male). Median follow-up was 19 months (interquartile range 8.8-40 months) with a median survival of 7.2 years (interquartile range 3.5-10.3 years). NLR was associated with 30-day mortality (OR 1.75; 95% CI 1.25-2.68; p<0.01). PLRs marginally predicted 1-year mortality (OR 1.01; 95% CI 1.00-1.02). However, only the STS-PROM score significantly predicted overall survival (hazard ratio 1.07; 95% CI 1.02-1.12; p=0.03) after adjustment for NLR and PLR. CONCLUSIONS: NLR is associated with 30-day mortality following TAVI. PLR was not a clinically significant predictor of mortality after TAVI. Only the STS-PROM score remained a significant predictor of overall survival.

19.
Artigo em Inglês | MEDLINE | ID: mdl-39380583

RESUMO

Objective: To evaluate early complications in prepectoral breast reconstruction. Methods: A retrospective cohort study including 180 consecutive cases of nipple-sparing mastectomy, comparing immediate breast reconstruction with subpectoral to prepectoral mammary implants in 2012-2022. Clinical and demographic characteristics and complications in the first three months following surgery were compared between the two techniques. Results: The prepectoral technique was used in 22 cases (12.2%) and the subpectoral in 158 (87.8%). Median age was higher in the prepectoral group (47 versus 43.8 years; p=0.038), as was body mass index (25.1 versus 23.8; p=0.002) and implant volume (447.5 versus 409 cc; p=0.001). The prepectoral technique was more associated with an inframammary fold (IMF) incision (19 cases, 86.4% versus 85, 53.8%) than with periareolar incisions (3 cases, 13.6% versus 73, 46.2%); (p=0.004). All cases in the prepectoral group underwent direct-to-implant reconstruction compared to 54 cases (34.2%) in the subpectoral group. Thirty-eight complications were recorded: 36 (22.8%) in the subpectoral group and 2 (9.1%) in the prepectoral group (p=0.24). Necrosis of the nipple-areola complex/skin flap occurred in 27 patients (17.1%) in the subpectoral group (prepectoral group: no cases; p=0.04). The groups were comparable regarding dehiscence, seroma, infection, and hematoma. Reconstruction failed in one case per group (p=0.230). In the multivariate analysis, IMF incision was associated with the prepectoral group (aOR: 34.72; 95%CI: 2.84-424.63). Conclusion: The incidence of early complications was comparable between the two techniques and compatible with previous reports. The clinical and demographic characteristics differed between the techniques. Randomized clinical trials are required.


Assuntos
Neoplasias da Mama , Mamoplastia , Mamilos , Complicações Pós-Operatórias , Humanos , Estudos Retrospectivos , Feminino , Pessoa de Meia-Idade , Adulto , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Mamilos/cirurgia , Mamoplastia/métodos , Neoplasias da Mama/cirurgia , Estudos de Coortes , Músculos Peitorais , Mastectomia Subcutânea/métodos , Fatores de Tempo , Implantes de Mama
20.
Artigo em Inglês | MEDLINE | ID: mdl-39380592

RESUMO

Objective: To compare outcomes in patients with repeated implantation failure undergoing Intracytoplasmic Sperm Injection/In vitro fertilization (IVF/ICSI) plus immunosuppressants such as prednisolone, prednisone, or cyclosporine A versus the use of IVF/ICSI alone. Data source: Databases were systematically searched in PubMed, Cochrane, and Embase databases in September 2023. Study Selection: Randomized clinical trials and observational studies with the outcomes of interest were included. Data collect: We computed odds ratios (ORs) for binary endpoints, with 95% confidence intervals (CIs). Heterogeneity was assessed using I2 statistics. Data were analyzed using Review Manager 5.4.The main outcomes were live birth, miscarriage, implantation rate, clinical pregnancy, and biochemical pregnancy. Data synthesis: Seven studies with 2,829 patients were included. Immunosuppressive treatments were used in 1,312 (46.37%). Cyclosporine A improved implantation rate (OR 1.48; 95% CI 1.01-2.18) and clinical pregnancy (1.89, 95% CI 1.14-3.14). Compared to non-immunosuppressive treatment, prednisolone and prednisone did not improve live birth (OR 1.13, 95% CI 0.88-1.46) and miscarriage (OR 1.49, 95% CI 1.07-2.09). Prednisolone showed no significant effect in patients undergoing IVF/ICSI, clinical pregnancy (OR 1.34; 95% CI 0.76-2.36), or implantation rate (OR 1.36; 95% CI 0.76-2.42). Conclusion: Cyclosporine A may promote implantation and clinical pregnancy rates. However, given the limited sample size, it is important to approach these findings with caution. Our results indicate that prednisolone and prednisone do not have any beneficial effects on clinical outcomes of IVF/ICSI patients with repeated implantation failure. PROSPERO: CRD42023449655.


Assuntos
Implantação do Embrião , Imunossupressores , Humanos , Feminino , Gravidez , Imunossupressores/uso terapêutico , Ciclosporina/uso terapêutico , Injeções de Esperma Intracitoplásmicas , Taxa de Gravidez , Técnicas de Reprodução Assistida , Prednisolona/uso terapêutico , Prednisolona/administração & dosagem , Prednisona/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...