Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Heart Rhythm ; 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39142547

RESUMO

BACKGROUND: Late potential (LP) elimination has been proposed as a surrogate endpoint for scar-related ventricular tachycardia (VT) ablation procedures. The characteristics, distribution, and predictors of persistent late potentials (pLPs) after ablation have not been studied. OBJECTIVE: The purpose of this study was to characterize the spatial distribution and features of pLP after catheter ablation of VT substrate with high-resolution mapping. METHODS: Cases of scar-related VT ablation with adequate pre- and postablation electroanatomic maps (EAMs) acquired exclusively using a high-density grid catheter were reviewed from 2021 to 2023. RESULTS: A total of 62 EAMs (pre- and postablation) from 31 cases using a high-density grid catheter were reviewed. pLPs were observed in 19 cases (61%) after ablation. New LP, spatially distinct from preablation LP, at the periphery of the ablation area comprised the majority of pLPs (16/19 [84%]). Isolated pLPs were more prevalent than fractionated pLPs, with a median amplitude of 0.26 mV (0.09-0.59 mV). The presence of pLP was associated with a significantly lower left ventricular ejection fraction (LVEF) and septal ablation but not low voltage, LP, or ablation area compared to absence of pLP (22.8% ± 7.8% vs 31.5% ± 8.0%, P = .008 for LVEF; 83% vs 44%, P = .033 for septal ablation). CONCLUSION: Formation of spatially distinct new LP after targeted VT ablation is common, especially in patients with lower LVEF and septal substrate independent of ablation burden. This finding highlights the limitations of complete LP elimination as an endpoint to VT ablation procedures.

2.
Artigo em Inglês | MEDLINE | ID: mdl-37966657

RESUMO

BACKGROUND: Brugada syndrome (BrS) is associated with abnormal electrophysiological properties at right ventricular epicardium, consisting of fragmented electrograms extending well beyond QRS termination. We aimed to evaluate the utility of signal-averaged electrocardiogram (SA-ECG) for the noninvasive assessment of late potentials (LP) and risk stratification of BrS patients. METHODS: A prospective, observational, single-center study of BrS patients is submitted to SA-ECG with the determination of the total filtered QRS duration (fQRS), root mean square voltage of the 40 ms terminal portion of the QRS (RMS40), and duration of the low-amplitude electric potential component of the terminal portion of the QRS (LAS40). LP were considered positive when above standard cut-offs: fQRS > 114 ms, RMS40 < 20 µV, and LAS40 > 38 ms. The rates of malignant arrhythmic events (MAEs), defined as sudden death or appropriate shocks, were compared in relation to clinical characteristics and SA-ECG findings. RESULTS: A total of 106 BrS patients (mean age, 48 ± 12 years, 67.9% male) were studied, 49% with type-1 spontaneous pattern and 81% asymptomatic. During a median follow up of 4.7 years, 10 patients (7.1%) suffered MAEs, including 4 sudden deaths. The presence of LP was significantly associated with the arrhythmic risk, which increased with the number of altered LP criteria. In comparison to the patients who had none or 1 altered LP criterium, MAE risk was 4.7 times higher in those with 2 altered criteria and 9.4 times higher in those with 3 altered LP criteria. CONCLUSIONS: SA-ECG may be a useful tool for risk stratification in BrS. The presence of 2 or 3 abnormal LP criteria could identify a subset of asymptomatic patients at high risk of arrhythmic events.

3.
Ann Noninvasive Electrocardiol ; 28(6): e13089, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37724719

RESUMO

BACKGROUND: The prevalence of Holter-based late potentials (H-LPs) in cases of fatal cardiac events has increased. Although the noise level of H-LP is higher than that of conventional real-time late potential (LP) recording, a procedure to reduce the noise severity in H-LP by increasing the averaging beats has not been investigated. METHODS: We enrolled 104 patients with post-myocardial infarction (MI) and 86 control participants. Among the patients, 30 reported sustained ventricular tachycardia (VT), and the remaining 74 had unrecorded VT. H-LPs were measured twice in all groups to evaluate the efficacy of increasing the averaging beats for H-LPs. Thereafter, the average of LP was calculated at 250 (default setting), 300, 400, 500, 600, 700, and 800 beats. RESULTS: Across all three groups (MI-VT group, MI non-VT group, and control group), the noise levels significantly decreased in consonance with the increase in averaging beats. In the MI-VT group, the H-LP positive rate considerably increased with the increase in the averaging beats from 250 to 800 both at night and daytime. In the MI-VT group, the LP parameters significantly deteriorated, which led to a positive judgment corresponding to the increment of the averaged night and day beats. The H-LP positive rates were unchanged in the MI non-VT and control groups, while the LP parameters remained consistent, despite the increased averaging beats in the MI non-VT and control groups. CONCLUSION: Increasing the calculated averaging beats in H-LPs can improve the sensitivity of predicting fatal cardiac events in patients with MI.


Assuntos
Infarto do Miocárdio , Taquicardia Ventricular , Humanos , Eletrocardiografia/métodos , Lipopolissacarídeos , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Taquicardia Ventricular/diagnóstico
4.
Medicina (Kaunas) ; 59(8)2023 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-37629750

RESUMO

Background and Objectives: Holter-based late potentials (LPs) are useful for predicting lethal arrhythmias in organic cardiac diseases. Although Holter-based LPs exhibit diurnal variation, no studies have evaluated the optimal timing of LP measurement over 24 h for predicting lethal arrhythmia that leads to sudden cardiac death. Thus, this study aimed to validate the most effective timing for Holter-based LP testing and to explore factors influencing the diurnal variability in LP parameters. Materials and Methods: We retrospectively analyzed 126 patients with post-myocardial infarction (MI) status and 60 control participants who underwent high-resolution Holter electrocardiography. Among the 126 post-MI patients, 23 developed sustained ventricular tachycardia (VT) (the MI-VT group), while 103 did not (the MI-non-VT group) during the observation period. Holter-based LPs were measured at 0:00, 4:00, 8:00, 12:00, 16:00, and 20:00, and heart rate variability analysis was simultaneously performed to investigate factors influencing the diurnal variability in LP parameters. Results: Holter-based LP parameters showed diurnal variation with significant deterioration at night and improvement during the day. Assessment at the time with the longest duration of low-amplitude signals < 40 µV in the filtered QRS complex terminus (LAS40) gave the highest receiver operating characteristics curve (area under the curve, 0.659) and the highest odds ratio (3.75; 95% confidence interval, 1.45-9.71; p = 0.006) for predicting VT. In the multiple regression analysis, heart rate and noise were significant factors affecting the LP parameters in the MI-VT and control groups. In the non-VT group, the LP parameters were significantly influenced by noise and parasympathetic heart rate variability parameters, such as logpNN50. Conclusions: For Holter-based LP measurements, the test accuracy was higher when the LP was measured at the time of the highest or worst value of LAS40. Changes in autonomic nervous system activity, including heart rate, were factors influencing diurnal variability. Increased parasympathetic activity or bradycardia may exacerbate Holter-based LP parameters.


Assuntos
Cardiopatias , Infarto do Miocárdio , Humanos , Lipopolissacarídeos , Estudos Retrospectivos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Infarto do Miocárdio/complicações
6.
Front Psychol ; 14: 1050892, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37057177

RESUMO

The perception of faces is one of the most specialized visual processes in the human brain and has been investigated by means of the early event-related potential component N170. However, face perception has mostly been studied in the conventional laboratory, i.e., monitor setups, offering rather distal presentation of faces as planar 2D-images. Increasing spatial proximity through Virtual Reality (VR) allows to present 3D, real-life-sized persons at personal distance to participants, thus creating a feeling of social involvement and adding a self-relevant value to the presented faces. The present study compared the perception of persons under conventional laboratory conditions (PC) with realistic conditions in VR. Paralleling standard designs, pictures of unknown persons and standard control images were presented in a PC- and a VR-modality. To investigate how the mechanisms of face perception differ under realistic conditions from those under conventional laboratory conditions, the typical face-specific N170 and subsequent components were analyzed in both modalities. Consistent with previous laboratory research, the N170 lost discriminatory power when translated to realistic conditions, as it only discriminated faces and controls under laboratory conditions. Most interestingly, analysis of the later component [230-420 ms] revealed more differentiated face-specific processing in VR, as indicated by distinctive, stimulus-specific topographies. Complemented by source analysis, the results on later latencies show that face-specific neural mechanisms are applied only under realistic conditions (A video abstract is available in the Supplementary material and via YouTube: https://youtu.be/TF8wiPUrpSY).

7.
Heart Rhythm ; 20(2): 224-230, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36244568

RESUMO

BACKGROUND: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is currently diagnosed using a combination of clinical features, imaging, electrocardiography, and genetic investigations. An abnormal signal-averaged electrocardiogram (SAECG) is defined as a minor diagnostic criterion by the 2010 Task Force Criteria, but doubts remain about the value of this investigation. OBJECTIVE: We evaluated the utility of the SAECG in diagnosing ARVC using the Canadian Arrhythmogenic Right Ventricular Cardiomyopathy Registry, a population representative registry of probands with ARVC and relatives, less influenced by referral bias. METHODS: Probands with ARVC and family members from the Canadian Arrhythmogenic Right Ventricular Cardiomyopathy Registry underwent phenotype review. SAECG parameters were compared individually and in combination between those with varying degrees of ARVC severity and healthy controls (family members of probands with ARVC and unexplained sudden death, free of evidence of cardiac disease). RESULTS: A total of 196 patients with ARVC and 205 controls were included (mean age 44 ± 15 years; 186 of 401 men [46%]). SAECG abnormalities were seen in 83 of 205 controls (40%), 33 of 68 patients with ARVC and mild disease (51%), and 31 of 42 with severe disease (74%). The SAECG associated strongly with imaging abnormalities (major: odds ratio 3.0, 95% confidence interval 1.3-6.9; minor: odds ratio 3.5, 95% confidence interval 0.7-16.5) but not with other aspects of phenotype. Patients carrying pathogenic variants but with minimal phenotype had similar SAECGs to healthy controls (filtered QRS duration 111.2 ± 11.2 ms vs 111 ± 7.6 ms, P = .93; duration of low amplitude signals < 40 µV 32.3 ± 8.9 ms vs 34.2 ± 7.2 ms, P = .32; root mean square of the terminal 40 ms of the filtered QRS complex 43.1 ± 25.2 ms vs 38.2 ± 20.2 ms, P = .38). CONCLUSION: The SAECG appears to be a surrogate marker for structural abnormalities seen on imaging in those with ARVC. Great caution is required in interpreting SAECG findings in those without other corroborating evidence of an ARVC phenotype.


Assuntos
Displasia Arritmogênica Ventricular Direita , Humanos , Displasia Arritmogênica Ventricular Direita/diagnóstico , Canadá/epidemiologia , Eletrocardiografia/métodos , Arritmias Cardíacas/diagnóstico
8.
J Arrhythm ; 38(6): 991-996, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36524028

RESUMO

Background: Previous studies have identified noninvasive methods for predicting atrial fibrillation (AF) recurrence after catheter ablation (CA). We assessed the association between AF recurrence and atrial late potentials (ALPs), which were measured using P-wave signal-averaged electrocardiography (P-SAECG). Methods: Consecutive patients with paroxysmal AF who underwent their first CA at our institution between August 2015 and August 2019 were enrolled. P-SAECG was performed before CA. Two ALP parameters were evaluated: the root-mean-square voltage during the terminal 20 ms (RMS20) and the P-wave duration (PWD). Positive ALPs were defined as an RMS20 <2.2 µV and/or a PWD >115 ms. Patients were allocated to either the recurrence or nonrecurrence group based on the presence of AF recurrence at the 1-year follow-up post-CA. Results: Of the 190 patients (age: 65 ± 11 years, 37% women) enrolled in this study, 21 (11%) had AF recurrence. The positive ALP rate was significantly higher in the recurrence group than in the nonrecurrence group (86% vs. 64%, p = .04), despite the absence of differences in other baseline characteristics between the two groups. In the multivariate analysis, positive ALP was an independent predictor of AF recurrence (odds ratio: 3.83, 95% confidence interval: 1.05-14.1, p = .04). Conclusions: Positive ALP on pre-CA P-SAECG is associated with AF recurrence after CA.

9.
Front Cardiovasc Med ; 9: 1000027, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36330001

RESUMO

Background: Low-voltage-substrate (LVS)-guided ablation for persistent atrial fibrillation (AF) has been described either in sinus rhythm (SR) or AF. Prolonged fractionated potentials (PFPs) may represent arrhythmogenic slow conduction substrate and potentially co-localize with LVS. We assess the spatial correlation of PFP identified in AF (PFP-AF) to those mapped in SR (PFP-SR). We further report the relationship between LVS and PFPs when mapped in AF or SR. Materials and methods: Thirty-eight patients with ablation naïve persistent AF underwent left atrial (LA) high-density mapping in AF and SR prior to catheter ablation. Areas presenting PFP-AF and PFP-SR were annotated during mapping on the LA geometry. Low-voltage areas (LVA) were quantified using a bipolar threshold of 0.5 mV during both AF and SR mapping. Concordance of fractionated potentials (CFP) (defined as the presence of PFPs in both rhythms within a radius of 6 mm) was quantified. Spatial distribution and correlation of PFP and CFP with LVA were assessed. The predictors for CFP were determined. Results: PFPs displayed low voltages both during AF (median 0.30 mV (Q1-Q3: 0.20-0.50 mV) and SR (median 0.35 mV (Q1-Q3: 0.20-0.56 mV). The duration of PFP-SR was measured at 61 ms (Q1-Q3: 51-76 ms). During SR, most PFP-SRs (89.4 and 97.2%) were located within LVA (<0.5 mV and <1.0 mV, respectively). Areas presenting PFP occurred more frequently in AF than in SR (median: 9.5 vs. 8.0, p = 0.005). Both PFP-AF and PFP-SR were predominantly located at anterior LA (>40%), followed by posterior LA (>20%) and septal LA (>15%). The extent of LVA < 0.5 mV was more extensive in AF (median: 25.2% of LA surface, Q1-Q3:16.6-50.5%) than in SR (median: 12.3%, Q1-Q3: 4.7-29.4%, p = 0.001). CFP in both rhythms occurred in 80% of PFP-SR and 59% of PFP-AF (p = 0.008). Notably, CFP was positively correlated to the extent of LVA in SR (p = 0.004), but not with LVA in AF (p = 0.226). Additionally, the extent of LVA < 0.5 mV in SR was the only significant predictor for CFP, with an optimal threshold of 16% predicting high (>80%) fractionation concordance in AF and SR. Conclusion: Substrate mapping in SR vs. AF reveals smaller areas of low voltage and fewer sites with PFP. PFP-SR are located within low-voltage areas in SR. There is a high degree of spatial agreement (80%) between PFP-AF and PFP-SR in patients with moderate LVA in SR (>16% of LA surface). These findings should be considered when substrate-based ablation strategies are applied in patients with the left atrial low-voltage substrate with recurrent persistent AF.

10.
J Cardiovasc Dev Dis ; 9(8)2022 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-35893222

RESUMO

A high-definition mapping catheter has been introduced, allowing for bipolar recording along and across the spline with a rapid assessment of voltage, activation, and directionality of conduction. We aimed to evaluate differences in mapping density, accuracy, time, and consequently RF time between different mapping catheters used for ventricular tachycardia (VT) ablation. We enrolled consecutive patients undergoing VT ablation at our center. Patients were divided into the LiveWire 2-2-2 mm catheter (group A) and the HD Grid SE (group B). Primary endpoints were total RF delivery time, the number of points acquired in sinus rhythm and VT, and the scar area. Fifty-one patients were enrolled, 22 in group A and 29 in group B. More points were acquired in the Grid group in sinus rhythm (SR) and during VT (2060.78 ± 1600.38 vs. 3278.63 ± 3214.45, p = 0.05; 4201.13 ± 5141.61 vs. 10,569.43 ± 13,644.94, p = 0.02, respectively). The scar area was smaller in group B (Bipolar area, cm2 4.52 ± 2.72 vs. 2.89 ± 2.81, p = 0.05. Unipolar area, cm2 7.47 ± 4.55 vs. 5.56 ± 2.79, p = 0.03). Radiofrequency (RF) time was shorter in the Grid group (30.52 ± 13.94 vs. 22.16 ± 11.03, p = 0.014). LPs and LAVAs were eliminated in overall >93% of patients. No differences were found in terms of arrhythmia-free survival at follow-up. In conclusion, the use of a high-definition mapping catheter was associated with significantly shorter mapping time during VT and RF time. Significantly more points were acquired in SR and during VT. During remap, we also observed more LAVAs and LPs requiring further ablation.

11.
Ann Noninvasive Electrocardiol ; 27(5): e12946, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35795926

RESUMO

BACKGROUND: Electrocardiographic non-invasive risk factors (NIRFs) have an important role in the arrhythmic risk stratification of post-myocardial infarction (post-MI) patients with preserved or mildly reduced left ventricular ejection fraction (LVEF). However, their specific relation to left ventricular systolic function remains unclear. We aimed to evaluate the association between NIRFs and LVEF in the patients included in the PRESERVE-EF trial. METHODS: We studied 575 post-MI ischemia-free patients with LVEF≥40% (mean age: 57.0 ± 10.4 years, 86.2% men). The following NIRFs were evaluated: premature ventricular complexes, non-sustained ventricular tachycardia (NSVT), late potentials (LPs), prolonged QTc, increased T-wave alternans, reduced heart rate variability, and abnormal deceleration capacity with abnormal turbulence. RESULTS: There was a statistically significant relationship between LPs (Chi-squared = 4.975; p < .05), nsVT (Chi-squared = 5.749, p < .05), PVCs (r= -.136; p < .01), and the LVEF. The multivariate linear regression analysis showed that LPs (p = .001) and NSVT (p < .001) were significant predictors of the LVEF. The results of the multivariate logistic regression analysis indicated that LPs (OR: 1.76; 95% CI: 1.02-3.05; p = .004) and NSVT (OR: 2.44; 95% CI: 1.18-5.04; p = .001) were independent predictors of the mildly reduced LVEF: 40%-49% versus the preserved LVEF: ≥50%. CONCLUSION: Late potentials and NSVT are independently related to reduced LVEF while they are independent predictors of mildly reduced LVEF versus the preserved LVEF. These findings may have important implications for the arrhythmic risk stratification of post-MI patients with mildly reduced or preserved LVEF.


Assuntos
Infarto do Miocárdio , Disfunção Ventricular Esquerda , Complexos Ventriculares Prematuros , Idoso , Eletrocardiografia , Feminino , Humanos , Lipopolissacarídeos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Fatores de Risco , Volume Sistólico/fisiologia , Função Ventricular Esquerda , Complexos Ventriculares Prematuros/complicações
12.
Heart Rhythm ; 19(10): 1650-1658, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35562054

RESUMO

BACKGROUND: The utility of late potentials on signal-averaged electrocardiography (SAECG) for risk stratification in patients with Brugada syndrome (BrS) remains controversial. Late potentials on conventional SAECG with Frank leads may be insufficiently sensitive to detect site-specific late potentials in right precordial leads. OBJECTIVE: The purpose of this study was to evaluate the utility of site-specific late potentials using a novel unipolar Holter-SAECG system for risk stratification in patients with BrS. METHODS: Consecutive symptomatic (n = 20) and asymptomatic (n = 21) patients with BrS who underwent investigation using conventional SAECG and a novel unipolar Holter-SAECG system were enrolled. We evaluated clinical characteristics and outcomes and compared late potentials on the 2 SAECGs between both groups and patients with and without cardiac events (CEs) (sudden cardiac death or sustained ventricular tachyarrhythmias) during the follow-up period. RESULTS: During mean follow-up of 76 months, 10 patients (24%) had CEs. There were no significant differences in late potentials on conventional SAECG between symptomatic and asymptomatic patients. On the Holter-SAECG system, RMS40 in lead V2 in the third intercostal space (3L-V2) at the nighttime was significantly lower in the symptomatic group than in the asymptomatic group (5.5 ± 0.8 µV and 8.2 ± 0.8 µV, respectively; P = .027). Univariate analysis of predictive values for CE showed that hazard ratios of daytime and nighttime RMS40 in lead 3L-V2 of <7.7 µV and <6.1 µV were 7.58 and 6.14, respectively. CONCLUSION: Site-specific late potentials in lead 3L-V2 measured using the novel Holter-SAECG system may be a useful marker for high-risk patients with BrS.


Assuntos
Síndrome de Brugada , Taquicardia Ventricular , Síndrome de Brugada/diagnóstico , Morte Súbita Cardíaca , Eletrocardiografia , Eletrocardiografia Ambulatorial , Humanos , Taquicardia Ventricular/diagnóstico
13.
Ann Noninvasive Electrocardiol ; 27(2): e12923, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34873791

RESUMO

BACKGROUND: Noninvasive electrocardiographic markers (NIEMs) are promising arrhythmic risk stratification tools for assessing the risk of sudden cardiac death. However, little is known about their utility in patients with chronic kidney disease (CKD) and organic heart disease. This study aimed to determine whether NIEMs can predict cardiac events in patients with CKD and structural heart disease (CKD-SHD). METHODS: We prospectively analyzed 183 CKD-SHD patients (median age, 69 years [interquartile range, 61-77 years]) who underwent 24-h ambulatory electrocardiographic monitoring and assessed the worst values for ambulatory-based late potentials (w-LPs), heart rate turbulence, and nonsustained ventricular tachycardia (NSVT). The primary endpoint was the occurrence of documented lethal ventricular tachyarrhythmias (ventricular fibrillation or sustained ventricular tachycardia) or cardiac death. The secondary endpoint was admission for cardiovascular causes. RESULTS: Thirteen patients reached the primary endpoint during a follow-up period of 24 ± 11 months. Cox univariate regression analysis showed that existence of w-LPs (hazard ratio [HR] = 6.04, 95% confidence interval [CI]: 1.4-22.3, p = .007) and NSVT [HR = 8.72, 95% CI: 2.8-26.5: p < .001] was significantly associated with the primary endpoint. Kaplan-Meier analysis demonstrated that the combination of w-LPs and NSVT resulted in a lower event-free survival rate than did other NIEMs (p < .0001). No NIEM was useful in predicting the secondary endpoint, although the left ventricular mass index was correlated with the secondary endpoint. CONCLUSION: The combination of w-LPs and NSVT was a significant risk factor for lethal ventricular tachyarrhythmias and cardiac death in CKD-SHD patients.


Assuntos
Insuficiência Renal Crônica , Taquicardia Ventricular , Idoso , Morte Súbita Cardíaca/etiologia , Eletrocardiografia/efeitos adversos , Eletrocardiografia Ambulatorial/métodos , Feminino , Humanos , Japão/epidemiologia , Lipopolissacarídeos , Masculino , Estudos Prospectivos , Insuficiência Renal Crônica/complicações , Medição de Risco , Fatores de Risco , Taquicardia Ventricular/complicações , Taquicardia Ventricular/diagnóstico , Fibrilação Ventricular/complicações
15.
Pacing Clin Electrophysiol ; 44(12): 2046-2053, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34648655

RESUMO

BACKGROUND: Late potentials (LPs) identified on the signal averaged electrocardiogram (SAECG) are a marker for an increased risk of arrhythmias in Brugada syndrome (BrS). Procainamide is a sodium channel blocker used to diagnose BrS. The effects of Procainamide on the SAECG in those with BrS and the significance of Procainamide-induced LPs are unknown. METHODS: Procainamide provocation was performed for suspected BrS with 12-lead and SAECG pre- and post-infusion. Filtered QRS duration (fQRSd), duration of low amplitude signals <40 µV (LAS40) and root-mean-square voltage in the terminal 40 ms (RMS40) were determined. RESULTS: Data from 150 patients were included in the analysis (mean age 44.5 years, 109 males). Procainamide increased fQRSd (Pre 118.8 ± 10.5 ms, post 121.2 ± 10.2 ms, p < 0.001) and LAS40 (Pre 38.7 ± 9.8 ms, post 40.2 ± 10.5 ms, p = 0.005) and decreased RMS40 (Pre 24.6 ± 12 ms, post 22.8 ± 12 ms, p = 0.002). LPs were present in 68/150 (45%) at baseline. Fifteen patients with negative baseline SAECGs had LPs unmasked by Procainamide, but six patients had LPs at baseline that were no longer present following Procainamide. Comparing those with normal hearts (n = 48) to those with a final diagnosis of BrS (n = 38), Procainamide prolonged fQRSd to a greater extent in those with BrS. Comparing those with Procainamide-induced LPs to those with no LPs at any time did not highlight any aspect of phenotype and did not correlate with a history of ventricular arrhythmias. CONCLUSIONS: Procainamide influences the SAECG, provoking LPs in a small proportion of patients. However, there is no evidence that Procainamide-induced LPs provide additional diagnostic information or aid risk stratification.


Assuntos
Síndrome de Brugada/fisiopatologia , Eletrocardiografia , Procainamida/administração & dosagem , Bloqueadores do Canal de Sódio Disparado por Voltagem/administração & dosagem , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
16.
Heart Rhythm O2 ; 2(3): 280-289, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34337579

RESUMO

BACKGROUND: The presence of dynamic substrate changes may facilitate functional block and reentry in ventricular tachycardia (VT). OBJECTIVE: We aimed to study dynamic ventricular repolarization changes in critical regions of the VT circuit during sensed single extrastimulus pacing known as the Sense Protocol (SP). METHODS: Twenty patients (aged 67 ± 9 years, 17 male) underwent VT ablation. A bipolar voltage map was obtained during sinus rhythm (SR) and right ventricular SP pacing at 20 ms above ventricular effective refractory period. Ventricular repolarization maps were constructed. Ventricular repolarization time (RT) was calculated from unipolar electrogram T waves, using the Wyatt method, as the dV/dtmax of the unipolar T wave. Entrainment or pace mapping confirmed critical sites for ablation. RESULTS: The median global repolarization range (max-min RT per patient) was 166 ms (interquartile range [IQR] 143-181 ms) during SR mapping vs 208 ms (IQR 182-234) during SP mapping (P = .0003 vs intrinsic rhythm). Regions of late potentials (LP) had a longer RT during SP mapping compared to regions without LP (mean 394 ± 40 ms vs 342 ± 25 ms, P < .001). In paired regions of normal myocardium there was no significant spatial dispersion of repolarization (SDR)/10 mm2 during SP mapping vs SR mapping (SDR 11 ± 6 ms vs 10 ± 6 ms, P = .54). SDR/10 mm2 was greater in critical areas of the VT circuit during SP mapping 63 ± 29 ms vs SR mapping 16 ± 9 ms (P < .001). CONCLUSION: Ventricular repolarization is prolonged in regions of LP and increases dynamically, resulting in dynamic SDR in critical areas of the VT circuit. These dynamic substrate changes may be an important factor that facilitates VT circuits.

17.
Ann Palliat Med ; 10(7): 7280-7288, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34263622

RESUMO

BACKGROUND: Ventricular late potentials (VLPs) detected by signal-averaged electrocardiogram are considered as an indicator of electrical instability in diseased myocardium. Little information exists about the VLPs and their effects on clinical prognosis in patients with obstructive hypertrophic cardiomyopathy (OHCM) undergoing septal myectomy. METHODS: Patients with OHCM who underwent septal myectomy from January 2019 to December 2019 were prospectively enrolled. All patients underwent signal-averaged electrocardiogram. Patients were subsequently divided into two groups based on the presence or absence of VLPs. All patients were followed up after surgery to obtain information of survival status and adverse events, including all-cause mortality, congestive heart failure requiring hospitalization, new-onset stroke, and unexplained syncope. RESULTS: In total, 128 patients (47.5±12.8 years, 57.8% male) were enrolled. There were 21 (16.4%) individuals in the VLPs-positive group and 107 (83.6%) individuals in the VLPs-negative group. There were no statistically significant differences in non-sustained ventricular tachycardia and late gadolinium enhancement on cardiovascular magnetic resonance images between the two groups. Eight adverse events were reported at the 14.9±4.1 months follow-up. The rates of adverse events in groups of VLPs-positive and VLPs-negative were 23.8% (5/21) and 2.8% (3/107) of cases, respectively. These events included three patients hospitalized for heart failure, two who experienced ischemic strokes, and three with unexplained syncope, respectively. Patients in the VLPs-positive group had a higher risk of adverse events than those in the VLPs-negative group (P<0.001). The presence of positive VLPs (hazard ratio =9.095, 95% confidence intervals: 2.080-39.776, P=0.003) was a strong independent risk factor of adverse events by multivariate Cox regression analysis. Cardiac function Class III or IV, as defined by the New York Heart Association classification, was also an independent risk factor of adverse events (hazard ratio =13.756, 95% confidence intervals: 1.667-113.510, P=0.015). CONCLUSIONS: VLPs may increase the risk of adverse events in patients with OHCM after septal myectomy, which may be used as a screening test for further risk stratification.


Assuntos
Cardiomiopatia Hipertrófica , Insuficiência Cardíaca , Meios de Contraste , Feminino , Gadolínio , Septos Cardíacos/cirurgia , Humanos , Masculino , Resultado do Tratamento
18.
J Electrocardiol ; 66: 79-83, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33831794

RESUMO

INTRODUCTION: The clinical utility of inferolateral early repolarisation (ER) and late potentials (LP) in children with Brugada Syndrome (BrS) has not been previously evaluated. The aim of this study was to determine the prevalence of electrocardiographic (ECG) abnormalities in children with BrS, and to investigate their relationship with clinical outcomes. METHODS: 43 patients with BrS and 47 controls aged ≤18 undergoing systematic clinical and ECG evaluation, including signal-averaged ECG (SAECG) and pharmacological provocation testing, between 2003 and 2019 were included. RESULTS: Four patients with BrS (9%) presented with a spontaneous type 1 Brugada pattern; the remaining 39 (91%) were diagnosed following ajmaline provocation testing. Twelve BrS patients (28%) had late potentials (LP) on SAECG compared to 1 (2%) in controls (p = 0.001). LP were more common in 5 patients with a high-risk phenotype (60% vs 24%) but this was not statistically significant. Twelve patients with BrS (28%) had inferolateral early repolarisation (ER) and 2 (5%) had fractionated QRS (f-QRS), but there were no statistically-significant differences with controls in these parameters. A significant arrhythmia (non-sustained ventricular tachycardia or atrial fibrillation) was seen in 4 patients (9%). CONCLUSIONS: This study shows a high prevalence of SAECG abnormalities in children with BrS compared with controls, but this was not significantly associated with a high-risk phenotype.


Assuntos
Síndrome de Brugada , Arritmias Cardíacas , Síndrome de Brugada/diagnóstico , Criança , Eletrocardiografia , Humanos , Prevalência
19.
J Interv Card Electrophysiol ; 60(1): 125-134, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32124150

RESUMO

PURPOSE: Signal-averaged ECG (SAECG) can detect inhomogeneous myocardial conduction in patients presenting with ventricular tachycardia (VT) after myocardial infarction. Radiofrequency ablation (RFCA) aims at elimination of the endocardial late potentials and non-inducibility of VT. Previously, we demonstrated that abnormal SAECG at baseline can return to normal after a successful VT ablation. The present research investigates the post-ablation changes in SAECG after RFCA of VT and their relation to the procedural long-term outcomes. METHODS: Thirty-three patients (31 male; age 68 ± 9 years; EF 36 ± 12%) with ischemic VT were prospectively enrolled to receive RFCA. One VT (range 1-7) per patient was ablated using substrate-guided RFCA and complete success was achieved in 28 (85%) cases. SAECG was performed before (t1), immediately after (t2), and at least 6 months (t3) after the RFCA. RESULTS: After RFCA, the amount of patients showing abnormal SAECG decreased from 82% initially (t1) to 57.6% post-interventionally (t2); P = 0.008; and remained unchanged thereafter in 57% (t3). Patients who experienced VT recurrence (VT+) during the follow-up period had broader averaged QRS (t2): (VT+) 150 ± 26 vs. (VT-) 129 ± 21 ms; P = 0.015, as well as longer LAS40 (t2): (VT+) 60 ± 26 vs. (VT-) 43 ± 18 ms; P = 0.03. Abnormal SAECG (t2) was a strong predictor for VT recurrence: HR 5.4; 95% CI 1.5-21. SAECG detected more late potentials in patients with inferior than in those with anterior scars: 95% vs. 58%; P = 0.016. CONCLUSIONS: RFCA of VT in the left ventricle can improve an abnormal SAECG in some patients after myocardial infarction. Normal SAECG after RFCA of VT is associated with a lower risk for VT recurrence and death.


Assuntos
Ablação por Cateter , Eletrocardiografia , Taquicardia Ventricular , Idoso , Arritmias Cardíacas , Endocárdio , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia
20.
JACC Clin Electrophysiol ; 6(14): 1783-1793, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33357574

RESUMO

OBJECTIVES: The goal of this study was to evaluate the role of dynamic substrate changes in facilitating conduction delay and re-entry in ventricular tachycardia (VT) circuits. BACKGROUND: The presence of dynamic substrate changes facilitate functional block and re-entry in VT but are rarely studied as part of clinical VT mapping. METHODS: Thirty patients (age 67 ± 9 years; 27 male subjects) underwent ablation. Mapping was performed with the Advisor HD Grid multipolar catheter. A bipolar voltage map was obtained during sinus rhythm (SR) and right ventricular sense protocol (SP) single extra pacing. SR and SP maps of late potentials (LP) and local abnormal ventricular activity (LAVA) were made and compared with critical sites for ablation, defined as sites of best entrainment or pace mapping. Ablation was then performed to critical sites, and LP/LAVA identified by the SP. RESULTS: At a median follow-up of 12 months, 90% of patients were free from antitachycardia pacing (ATP) or implantable cardioverter-defibrillator shocks. SP pacing resulted in a larger area of LP identified for ablation (19.3 mm2 vs. 6.4 mm2) during SR mapping (p = 0.001), with a sensitivity of 87% and a specificity of 96%, compared with 78% and 65%, respectively, in SR. CONCLUSIONS: LP and LAVA observed during the SP were able to identify regions critical for ablation in VT with a greater accuracy than SR mapping. This may improve substrate characterization in VT ablation. The combination of ablation to critical sites and SP-derived LP/LAVA requires further assessment in a randomized comparator study.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Idoso , Ventrículos do Coração/cirurgia , Humanos , Masculino , Taquicardia Ventricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...