1.
Artigo em Inglês | MEDLINE | ID: mdl-37486261

RESUMO

OBJECTIVES: There are several surgical approaches for explanting a left ventricular assist device (LVAD) after recovery of cardiac function. Thus, remaining ventricular assist device components may bear significant risks of infection or thrombosis. We hereby report our technique and two-center experience with explantation of LVADs using a new double-patch technique. METHODS: From March 2019 to April 2021, five patients underwent LVAD explantation after myocardial recovery (HVAD, n = 2; HeartMate 3, n = 3). The mean patient age was 50.3 years (100% male); the mean time on the LVAD was 23.1 ± 20.8 months. The aetiology of the primary heart failure was dilated cardiomyopathy (n = 4) and myocarditis (n = 1).LVAD explantation was performed using a median sternotomy and cardiopulmonary bypass. The LVAD was stopped, and the outflow graft was clamped. The outflow graft was ligated and sutured close to the aortic anastomosis. The driveline was clipped and removed. Under induced fibrillation, the attachment of the LVAD was released from the apical cuff and the LVAD was removed. A round pericardial patch was fixed from the inner of the ventricle. This step sealed the apex of the heart. An additional Gore-Tex patch was continuously sutured epicardially over the suture ring. RESULTS: The 5 cases showed technically uncomplicated explantation of the LVADs. During the follow-up of a mean of 16.4 ± 16.9 months, we observed 100% survival. There were no bleeding complications or thromboembolic events during the follow-up period. CONCLUSIONS: LVAD explantation with the double-patch technique is feasible and safe. This technique allows discontinuation of anticoagulation. The 30-day survival was 100%. Further studies are needed to provide better evidence for LVAD explantation and long-term follow-up.

2.
Eur J Cardiothorac Surg ; 59(4): 855-862, 2021 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-33367693

RESUMO

OBJECTIVES: Myocardial recovery is a rare phenomenon in left ventricular assist device (LVAD) therapy. Surgical LVAD removal is associated with the risk of cardiac failure, and the individual evaluation of sufficient myocardial recovery is crucial. Thus, complete device explantation is not consistently performed to minimize perioperative risk. However, the remaining ventricular assist device components bear significant risks of infection or thrombosis. Therefore, we developed this study to evaluate a complete LVAD explantation protocol. METHODS: All patients in our institution who had an LVAD explanted were enrolled in the study. Explant surgery involved removal of the driveline, pump housing, sewing ring and outflow graft. The ventricular wall was reconstructed by double patch plasty. Our analysis focused on surgical and postoperative outcome parameters, including all-cause mortality and major adverse cardiac and cerebrovascular events. RESULTS: A total of 12 patients (HVAD, n = 5; HeartMate II, n = 3; HeartMate 3, n = 4) had myocardial recovery and qualified for our LVAD explantation study protocol [median age: 40 years, interquartile range (IQR) 33-52 years; 50% men]. Primary heart failure aetiology: myocarditis (n = 5), dilated cardiomyopathy (n = 4), toxic cardiomyopathy (n = 2) and valvular heart failure (n = 1). The median average duration on LVAD was 10 months (25-75%: IQR 8.5-30 months). The median left ventricular ejection fraction was 15% (IQR 13-18%) at LVAD implantation and 50% (IQR 45-50%) before LVAD explantation (P = 0.0025).The 30-day survival was 100%. The 1-year survival was 91.7%. All patients were discharged after a median 13 days (IQR 10-18 days) postoperatively. No patient had major adverse cardiac and cerebrovascular events. The New York Heart Association functional class remained consistent during the follow-up period (median New York Heart Association functional class: II, IQR II-II class) including preservation of ventricular function. CONCLUSIONS: Complete LVAD explantation with ventricular patch plasty is feasible and has consistent long-term results.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Adulto , Remoção de Dispositivo/efeitos adversos , Feminino , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
3.
Interact Cardiovasc Thorac Surg ; 32(2): 298-305, 2021 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-33236054

RESUMO

OBJECTIVES: Left ventricular assist device (LVAD) implantation for end-stage heart failure patients has been on the rise, providing a reliable long-term option. For some LVAD patients, longer term LV unloading leads to recovery; hence, the need for evaluating potential myocardial recovery and weaning eligibility has emerged. METHODS: All patients who underwent contemporary LVAD explantation at our institution between 2009 and 2020 were included in the study. Patients in New York Heart Association I, left ventricular ejection fraction >40%, a cardiac index >2.4 l/min and a peak oxygen intake >50% predicted underwent a 4-phase weaning assessment. A minimally invasive approach using a titanium plug was the surgery of choice in the most recent explants. Kaplan-Meier curves were used to estimate the survival at 1 and 5 years. RESULTS: Twenty-six patients (17 HeartMate II, 9 HeartWare) underwent LVAD explantation after a median 317 days of support [IQ (212-518)], range 131-1437. Mean age at explant was 35.8 ± 12.7 years and 85% were males. Idiopathic dilated cardiomyopathy was the underlying diagnosis in 70% of cases. Thirteen (48%) patients were on short-term mechanical circulatory support and 60% required intensive care unit admission prior to the LVAD implantation. At 1 year, Kaplan-Meier estimated survival was 88%, whereas at 6 years, it was 77%. The average left ventricular ejection fraction at 1 year post-explant was 44.25% ± 8.44. CONCLUSIONS: The use of a standardized weaning protocol (echocardiographic and invasive) and a minimally invasive LVAD explant technique minimizes periprocedural complications and leads to good long-term device-free survival rates.


Assuntos
Remoção de Dispositivo , Coração Auxiliar , Função Ventricular Esquerda , Adulto , Cardiomiopatia Dilatada/fisiopatologia , Ecocardiografia , Insuficiência Cardíaca/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , New York , Volume Sistólico , Resultado do Tratamento
4.
Eur J Cardiothorac Surg ; 57(3): 604-606, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-32077482

RESUMO

Myocardial recovery in left ventricular assist device patients is a rare opportunity to explant the assist device. Despite myocardial recovery, these patients remain high-risk candidates. Short, effective procedures are the key to successful left ventricular assist device explantation. Conventional methods such as ventriculoplasty are extensive and challenging procedures. Thus, an explantation tool was developed in order to simplify HeartMate 3 (Abbott Cooperation, Abbott Park, Ill, USA) explantation. A customized metal plug was designed to fit into the HeartMate 3-sewing ring. We now report the successful first-in-man use of this novel plug for HeartMate 3 explantation.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Remoção de Dispositivo , Insuficiência Cardíaca/cirurgia , Humanos