Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Bioact Mater ; 37: 407-423, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38689660

RESUMO

Traditional optical waveguides or mediums are often silica-based materials, but their applications in biomedicine and healthcare are limited due to the poor biocompatibility and unsuitable mechanical properties. In term of the applications in human body, a biocompatible hydrogel system with excellent optical transparency and mechanical flexibility could be beneficial. In this review, we explore the different designs of hydrogel-based optical waveguides derived from natural and synthetic sources. We highlighted key developments such as light emitting contact lenses, implantable optical fibres, biosensing systems, luminating and fluorescent materials. Finally, we expand further on the challenges and perspectives for hydrogel waveguides to achieve clinical applications.

2.
Sensors (Basel) ; 24(2)2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38257474

RESUMO

White Rabbit (WR) is an optical fibre-based time-frequency synchronization technology typically used in timekeeping laboratories for distributing time-frequency signals from a reference clock to distant locations. The accuracy of the received signals at the user end can be affected by random noise processes present in the WR network due to the internal electronic components of WR devices. In this paper, we investigate the presence of random noise processes in the WR network. We then study their statistical properties and model the distribution based on experimentally recorded measurements. According to our study, the probability density function (PDF) follows a Gaussian mixture model (GMM) with varying distribution parameters, and the correlation analysis indicates a strong correlation of the phase noise process over the temporal samples. Furthermore, the developed phase noise models have also been verified by comparing them against additional experimental data. Finally, we present the methodology to generate the phase noise process using computer simulations with the PDF and correlation models developed in this work to help algorithm developers and equipment manufacturers make use of our results.

3.
J Opt ; 26(1): 013001, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38116399

RESUMO

Optical sensors and sensing technologies are playing a more and more important role in our modern world. From micro-probes to large devices used in such diverse areas like medical diagnosis, defence, monitoring of industrial and environmental conditions, optics can be used in a variety of ways to achieve compact, low cost, stand-off sensing with extreme sensitivity and selectivity. Actually, the challenges to the design and functioning of an optical sensor for a particular application requires intimate knowledge of the optical, material, and environmental properties that can affect its performance. This roadmap on optical sensors addresses different technologies and application areas. It is constituted by twelve contributions authored by world-leading experts, providing insight into the current state-of-the-art and the challenges their respective fields face. Two articles address the area of optical fibre sensors, encompassing both conventional and specialty optical fibres. Several other articles are dedicated to laser-based sensors, micro- and nano-engineered sensors, whispering-gallery mode and plasmonic sensors. The use of optical sensors in chemical, biological and biomedical areas is discussed in some other papers. Different approaches required to satisfy applications at visible, infrared and THz spectral regions are also discussed.

4.
Sensors (Basel) ; 22(19)2022 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-36236411

RESUMO

In nuclear power plants, particle accelerators, and other nuclear facilities, measuring the level of ionising gamma radiation is critical for the safety and management of the operation and the environment's protection. However, in many cases, it is impossible to monitor ionising radiation directly at the required location continuously. This is typically either due to the lack of space to accommodate the entire dosimeter or in environments with high ionising radiation activity, electromagnetic radiation, and temperature, which significantly shorten electronics' lifetime. To allow for radiation measurement in such scenarios, we designed a fibre optic dosimeter that introduces an optical fibre link to deliver the scintillation radiation between the ionising radiation sensor and the detectors. The sensors can thus be placed in space-constrained and electronically hostile locations. We used silica optical fibres that withstand high radiation doses, high temperatures, and electromagnetic interference. We use a single photon counter and a photomultiplier to detect the transmitted scintillation radiation. We have shown that selected optical fibres, combined with different scintillation materials, are suitable for measuring gamma radiation levels in hundreds of kBq. We present the architecture of the dosimeter and its experimental characterisation with several combinations of optical fibres, detectors, and scintillation crystals.


Assuntos
Fibras Ópticas , Dosímetros de Radiação , Fenômenos Físicos , Radiometria , Contagem de Cintilação , Dióxido de Silício
5.
Sensors (Basel) ; 22(3)2022 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-35161487

RESUMO

As the drive to improve the cost, performance characteristics and safety of lithium-ion batteries increases with adoption, one area where significant value could be added is that of battery diagnostics. This paper documents an investigation into the use of plasmonic-based optical fibre sensors, inserted internally into 1.4 Ah lithium-ion pouch cells, as a real time and in-situ diagnostic technique. The successful implementation of the fibres inside pouch cells is detailed and promising correlation with battery state is reported, while having negligible impact on cell performance in terms of capacity and columbic efficiency. The testing carried out includes standard cycling and galvanostatic intermittent titration technique (GITT) tests, and the use of a reference electrode to correlate with the anode and cathode readings separately. Further observations are made around the sensor and analyte interaction mechanisms, robustness of sensors and suggested further developments. These finding show that a plasmonic-based optical fibre sensor may have potential as an opto-electrochemical diagnostic technique for lithium-ion batteries, offering an unprecedented view into internal cell phenomena.


Assuntos
Lítio , Fibras Ópticas , Fontes de Energia Elétrica , Eletrodos , Íons
6.
Int J Mol Sci ; 22(19)2021 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-34639185

RESUMO

Local activation of an anti-cancer drug when and where needed can improve selectivity and reduce undesirable side effects. Photoswitchable drugs can be selectively switched between active and inactive states by illumination with light; however, the clinical development of these drugs has been restricted by the difficulty in delivering light deep into tissue where needed. Optical fibres have great potential for light delivery in vivo, but their use in facilitating photoswitching in anti-cancer compounds has not yet been explored. In this paper, a photoswitchable chemotherapeutic is switched using an optical fibre, and the cytotoxicity of each state is measured against HCT-116 colorectal cancer cells. The performance of optical-fibre-enabled photoswitching is characterised through its dose response. The UV-Vis spectra confirm light delivered by an optical fibre effectively enables photoswitching. The activated drug is shown to be twice as effective as the inactive drug in causing cancer cell death, characterised using an MTT assay and fluorescent microscopy. This is the first study in which a photoswitchable anti-cancer compound is switched using an optical fibre and demonstrates the feasibility of using optical fibres to activate photoswitchable drugs for potential future clinical applications.


Assuntos
Antineoplásicos/farmacologia , Neoplasias Colorretais/tratamento farmacológico , Dimetil Sulfóxido/química , Fibras Ópticas/estatística & dados numéricos , Antineoplásicos/química , Sobrevivência Celular , Humanos , Células Tumorais Cultivadas
7.
Data Brief ; 31: 106017, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32760765

RESUMO

This data article provides useful information often required for numerical modeling of the so-called microbond tests. It includes the experimental and simulation data of the microbond testing using Fibre Bragg Grating (FBG) fibres for optical strains. Microbond testing was performed on five different droplets of varying embedded length and diameter to collect the data. Finite element simulation was carried out and modelling was validated, by using two variables force and strain, to collect the data. The output data of the fitted models is given and is also visualized via graphs of force-strain derivative curves. The data of the simulations is provided for different finite element mesh densities. Here, to clarify the type and form of the data for the use by readers, the energy distribution curves describing various functionalities of the droplet, fibre and interface are presented. For further reading, the interpretation and analysis of this data can be found in a research article titled "3D interfacial debonding during microbond testing: Advantages of local strain recording" (R. Dsouza et al., 2020) [1].

8.
Philos Trans A Math Phys Eng Sci ; 378(2177): 20190231, 2020 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-32684129

RESUMO

The photonic crystal fibre (PCF) is a unique medium giving us the opportunity to perform experiments in carefully chosen regimes with precision and control. Using PCFs, we can perform analogue gravity experiments to study the physics of Hawking radiation and related processes such as resonant radiation. We discuss the similarities and differences between these processes and experimentally investigate the limits of effects of this type, dis- covering a new regime of record efficiency. We measure a 60% energy conversion efficiency from a pump to a visible femtosecond pulse by the process of resonant radiation, and demonstrate its extraordinary tunability in wavelength and bandwidth. Beyond analogue gravity, these femtosecond visible pulses provide a desirable laser source useful across a variety of modern scientific fields. This article is part of a discussion meeting issue 'The next generation of analogue gravity experiments'.

9.
Philos Trans A Math Phys Eng Sci ; 378(2177): 20190223, 2020 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-32684130

RESUMO

Hawking radiation was originally proposed in astrophysics, but it has been generalized and extended to other physical systems receiving the name of analogue Hawking radiation. In the last two decades, several attempts have been made to measure it in a laboratory, and one of the most successful systems is in optics. Light interacting in a dielectric material causes an analogue Hawking effect, in fact, its stimulated version has already been detected and the search for the spontaneous signal is currently ongoing. We briefly review the general derivation of Hawking radiation, then we focus on the optical analogue and present some novel numerical results. Finally, we call for a generalization of the term Hawking radiation. This article is part of a discussion meeting issue 'The next generation of analogue gravity experiments'.

10.
Biosens Bioelectron ; 156: 112126, 2020 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-32275577

RESUMO

Soft molecularly imprinted nanogels (nanoMIPs), selective for human transferrin (HTR), were prepared via a template assisted synthesis. Owing to their soft matter, the nanoMIPs were observed to deform at binding to HTR: while no relevant changes were observed in the hydrodynamic sizes of HTR-free compared to HTR-loaded nanoMIPs, the HTR binding resulted in a significant increment of the nanoMIP stiffness, with the mean Young's modulus measured by AFM passing from 17 ± 6 kPa to 56 ± 18 kPa. When coupled to a plastic optical fibre (POF) plasmonic platform, the analyte-induced nanoMIP-deformations amplified the resonance shift, enabling to attain ultra-low sensitivities (LOD = 1.2 fM; linear dynamic range of concentrations from 1.2 fM to 1.8 pM). Therefore, soft molecularly imprinted nanogels that obey to analyte-induced deformation stand as a novel class of sensitivity-gain structures for plasmonic sensing.


Assuntos
Técnicas Biossensoriais/métodos , Impressão Molecular/métodos , Nanogéis/química , Transferrina/análise , Módulo de Elasticidade , Humanos , Limite de Detecção
11.
Polymers (Basel) ; 11(11)2019 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-31652952

RESUMO

The performance of a precisely controlled drilling technique is critical in the fabrication process of microstructured polymer optical fibres. For the creation of a holey preform, adequate drilling bits with large length-to-diameter ratios provide the ability of machining preforms with complex structures and large lengths in a relatively short time. In this work, we analysed different drilling bits and techniques that can be employed for the creation of such preforms, and key parameters characterising the quality of the drilled holes, such as surface rugosity, diameter deviation, coaxiality and cylindricity were measured. For this purpose, based on theoretical simulations, four rings of air holes arranged in a hexagonal pattern were drilled in the preforms with different drill bits, and the experimental results for the above mentioned parameters have been presented. Additionally, optical power distribution of the fabricated microstructured polymer optical fibres was theoretically calculated and experimentally measured.

12.
Sensors (Basel) ; 19(13)2019 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-31252550

RESUMO

We present a polymer fibre Bragg grating sensor and its sensitivity to gamma radiation by observing the reflected spectral profile. The Bragg grating is femtosecond inscribed within a perfluorinated CYTOP fibre and the alteration of the Bragg wavelength corresponds to the total radiation dose received. Over a total dose of 41 k Gy, the fibre demonstrates a sensitivity of - 26.2 p m / k Gy and a resolution of 40 Gy. Under active consideration for the instrumentation of nuclear waste repositories, this study gives a better understanding of the effects of gamma radiation upon Bragg gratings in CYTOP fibres.

13.
Sensors (Basel) ; 17(6)2017 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-28608831

RESUMO

This paper presents the state of the art distributed sensing systems, based on optical fibres, developed and qualified for the French Cigéo project, the underground repository for high level and intermediate level long-lived radioactive wastes. Four main parameters, namely strain, temperature, radiation and hydrogen concentration are currently investigated by optical fibre sensors, as well as the tolerances of selected technologies to the unique constraints of the Cigéo's severe environment. Using fluorine-doped silica optical fibre surrounded by a carbon layer and polyimide coating, it is possible to exploit its Raman, Brillouin and Rayleigh scattering signatures to achieve the distributed sensing of the temperature and the strain inside the repository cells of radioactive wastes. Regarding the dose measurement, promising solutions are proposed based on Radiation Induced Attenuation (RIA) responses of sensitive fibres such as the P-doped ones. While for hydrogen measurements, the potential of specialty optical fibres with Pd particles embedded in their silica matrix is currently studied for this gas monitoring through its impact on the fibre Brillouin signature evolution.

14.
J R Soc Interface ; 14(128)2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28275123

RESUMO

Knowledge of an individual's skin condition is important for pressure ulcer prevention. Detecting early changes in skin through perfusion, oxygen saturation values, and pressure on tissue and subsequent therapeutic intervention could increase patients' quality of life drastically. However, most existing sensing options create additional risk of ulcer development due to further pressure on and chafing of the skin. Here, as a first component, we present a flexible, photonic textile-based sensor for the continuous monitoring of the heartbeat and blood flow. Polymer optical fibres (POFs) are melt-spun continuously and characterized optically and mechanically before being embroidered. The resulting sensor shows flexibility when embroidered into a moisture-wicking fabric, and withstands disinfection with hospital-type laundry cycles. Additionally, the new sensor textile shows a lower static coefficient of friction (COF) than conventionally used bedsheets in both dry and sweaty conditions versus a skin model. Finally, we demonstrate the functionality of our sensor by measuring the heartbeat at the forehead in reflection mode and comparing it with commercial finger photoplethysmography for several subjects. Our results will allow the development of flexible, individualized, and fully textile-integrated wearable sensors for sensitive skin conditions and general long-term monitoring of patients with risk for pressure ulcer.


Assuntos
Coração/fisiopatologia , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Contração Miocárdica , Fibras Ópticas , Pele , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Masculino
15.
Phys Med ; 32(9): 1124-34, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27575280

RESUMO

This paper describes the design and characterization of a charged particle imaging system composed of a position sensitive detector and residual range detector. The position detector consists of two identical overlying and orthogonal planes each of which consists of two layers of pre-aligned and juxtaposed scintillating fibres. The 500µm square section fibres are optically coupled to two Silicon Photomultiplier arrays using a channel reduction system patented by the Istituto Nazionale di Fisica Nucleare. The residual range detector consists of sixty parallel layers of the same fibres used in the position detector each of which is optically coupled to a Silicon Photomultiplier array by wavelength shifting fibres. The sensitive area of the two detectors is 9×9cm(2). Characterising the position sensitive and the residual range detectors to reconstruct the radiography, is fundamental to validating the detectors' designs. The proton radiography of a calibrated target in imaging conditions is presented. The spatial resolution of the position sensitive detector is about 150µm and the range resolution is about 170µm. The performance of the prototypes were tested at CATANA proton therapy facility (Laboratori Nazionali del Sud, INFN, Catania) with energy up to 58MeV and rate of about 10(6) particles per second. The comparison between the simulations and measurements confirms the validity of this system.


Assuntos
Carbono/química , Íons , Neoplasias/radioterapia , Fibras Ópticas , Terapia com Prótons/métodos , Radiografia/métodos , Calibragem , Simulação por Computador , Desenho de Equipamento , Humanos , Método de Monte Carlo , Prótons , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes , Silício/química , Água/química
16.
Philos Trans A Math Phys Eng Sci ; 374(2062)2016 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-26809569

RESUMO

Researchers are within a factor of 2 or so from realizing the maximum practical transmission capacity of conventional single-mode fibre transmission technology. It is therefore timely to consider new technological approaches offering the potential for more cost-effective scaling of network capacity than simply installing more and more conventional single-mode systems in parallel. In this paper, I review physical layer options that can be considered to address this requirement including the potential for reduction in both fibre loss and nonlinearity for single-mode fibres, the development of ultra-broadband fibre amplifiers and finally the use of space division multiplexing.

17.
Sens Actuators B Chem ; 222: 531-535, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26726286

RESUMO

Very fast sensors that are able to track rapid changes in oxygen partial pressure (PO2) in the gas and liquid phases are increasingly required in scientific research - particularly in the life sciences. Recent interest in monitoring very fast changes in the PO2 of arterial blood in some respiratory failure conditions is one such example. Previous attempts to design fast intravascular electrochemical oxygen sensors for use in physiology and medicine have failed to meet the criteria that are now required in modern investigations. However, miniature photonic devices are capable of meeting this need. In this article, we present an inexpensive polymer type fibre-optic, oxygen sensor that is two orders of magnitude faster than conventional electrochemical oxygen sensors. It is constructed with biologically inert polymer materials and is both sufficiently small and robust for direct insertion in to a human artery. The sensors were tested and evaluated in both a gas testing chamber and in a flowing liquid test system. The results showed a very fast T90 response time, typically circa 20 ms when tested in the gas phase, and circa 100 ms in flowing liquid.

18.
Anal Bioanal Chem ; 407(24): 7467-75, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26232932

RESUMO

We present a novel method for in-plane digital microfluidic spectroscopy. In this technique, a custom manifold (.stl file available online as ESM) aligns optical fibres with a digital microfluidic device, allowing optical measurements to be made in the plane of the device. Because of the greater width vs thickness of a droplet on-device, the in-plane alignment of this technique allows it to outperform the sensitivity of vertical absorbance measurements on digital microfluidic (DMF) devices by ∼14×. The new system also has greater calibration sensitivity for thymol blue measurements than the popular NanoDrop system by ∼2.5×. The improvements in absorbance sensitivity result from increased path length, as well as from additional effects likely caused by liquid lensing, in which the presence of a water droplet between optical fibres increases fibre-to-fibre transmission of light by ∼2× through refraction and internal reflection. For interrogation of dilute samples, stretching of droplets using digital microfluidic electrodes and adjustment of fibre-to-fibre gap width allows absorbance path length to be changed on-demand. We anticipate this new digital microfluidic optical fibre absorbance and fluorescence measurement system will be useful for a wide variety of analytical applications involving microvolume samples with digital microfluidics.


Assuntos
Dispositivos Lab-On-A-Chip , Fibras Ópticas , Análise Espectral/métodos
19.
Sensors (Basel) ; 8(5): 3406-3428, 2008 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-27879885

RESUMO

The main objective of this project is to implement the multiple fan beam projection technique using optical fibre sensors with the aim to achieve a high data acquisition rate. Multiple fan beam projection technique here is defined as allowing more than one emitter to transmit light at the same time using the switch-mode fan beam method. For the thirty-two pairs of sensors used, the 2-projection technique and 4- projection technique are being investigated. Sixteen sets of projections will complete one frame of light emission for the 2-projection technique while eight sets of projection will complete one frame of light emission for the 4-projection technique. In order to facilitate data acquisition process, PIC microcontroller and the sample and hold circuit are being used. This paper summarizes the hardware configuration and design for this project.

20.
Med Phys ; 32(7Part1): 2271-2278, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28493586

RESUMO

Scintillation dosimetry is a promising avenue for evaluating dose patterns delivered by intensity-modulated radiation therapy plans or for the small fields involved in stereotactic radiosurgery. However, the increase in signal has been the goal for many authors. In this paper, a comparison is made between plastic scintillating fibers and plastic scintillator. The collection of scintillation light was measured experimentally for four commercial models of scintillating fibers (BCF-12, BCF-60, SCSF-78, SCSF-3HF) and two models of plastic scintillators (BC-400, BC-408). The emission spectra of all six scintillators were obtained by using an optical spectrum analyzer and they were compared with theoretical behavior. For scintillation in the blue region, the signal intensity of a singly clad scintillating fiber (BCF-12) was 120% of that of the plastic scintillator (BC-400). For the multiclad fiber (SCSF-78), the signal reached 144% of that of the plastic scintillator. The intensity of the green scintillating fibers was lower than that of the plastic scintillator: 47% for the singly clad fiber (BCF-60) and 77% for the multiclad fiber (SCSF-3HF). The collected light was studied as a function of the scintillator length and radius for a cylindrical probe. We found that symmetric detectors with nearly the same spatial resolution in each direction (2 mm in diameter by 3 mm in length) could be made with a signal equivalent to those of the more commonly used asymmetric scintillators. With augmentation of the signal-to-noise ratio in consideration, this paper presents a series of comparisons that should provide insight into selection of a scintillator type and volume for development of a medical dosimeter.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...