1.
J Radiol Prot ; 44(2)2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38530296

RESUMO

Calibration of 22 gamma camera units was performed at 15 hospitals in southern and western Sweden to estimate137Cs contamination in humans in a supine static geometry, with a new developed calibration protocol and phantom. The minimum detectable activities (MDAs) and the estimated committed effective doses (CEDs) were calculated for each calibration. Generic calibration factors were calculated for five predetermined groups based on the detector type and manufacturer. Group 1 and 2 included NaI-based gamma cameras from General Electrics (GEs) with a crystal thickness of 5/8'' and 3/8'' respectively. Group 3 and 4 included NaI-based gamma cameras from Siemens Healthineers with a crystal thickness of 3/8'', with a similar energy window as the GE NaI-based cameras and a dual window respectively. Group 5 included semiconductor-based gamma cameras from GE with a CdZnTe (CZT) detector. The generic calibration factors were 60.0 cps kBq-1, 52.3 cps kBq-1, 50.3 cps kBq-1, 53.2 cps kBq-1and 48.4 cps kBq-1for group 1, 2, 3, 4, and 5 respectively. The MDAs ranged between 169 and 1130 Bq for all groups, with measurement times of 1-10 min, corresponding to a CED of 4.77-77.6µSv. A dead time analysis was performed for group 1 and suggested a dead time of 3.17µs for137Cs measurements. The dead time analysis showed that a maximum count rate of 232 kcps could be measured in the calibration geometry, corresponding to a CED of 108-263 mSv. It has been shown that semiconductor-based gamma cameras with CZT detectors are feasible for estimating137Cs contamination. The generic calibration factors derived in this study can be used for gamma cameras of the same models in other hospitals, for measurements in the same measurement geometry. This will increase the measurement capability for estimating internal137Cs contamination in the recovery phase following radiological or nuclear events.


Assuntos
Cádmio , Radioisótopos de Césio , Câmaras gama , Telúrio , Zinco , Humanos , Calibragem
2.
J Radiol Prot ; 43(1)2023 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-36749985

RESUMO

A survey was performed of the available gamma camera models and whole-body counters (WBCs) in Sweden, revealing that there are about 75 gamma cameras and 15 WBCs currently in operation in Sweden. One of the most common gamma camera models (GE Discovery NM/CT 670 Pro), with the collimators removed, was calibrated for152Eu,137Cs,60Co and40K in three different measurement geometries (supine, close-up sitting and distant sitting) for six different phantom sizes (12-110 kg). Minimum detectable activities (MDAs) were calculated for the gamma camera and a typical WBC, both at the Sahlgrenska University Hospital in Gothenburg, Sweden. An energy window of 30-510 keV was used to calibrate the gamma camera. The calibration factors for this gamma camera for supine and close-up sitting geometry, including all phantom sizes, were 138-208 cps kBq-1for152Eu, 63-83 cps kBq-1for137Cs and 99-126 cps kBq-1for60Co; the MDAs were 50-73 Bq for152Eu, 125-198 Bq for137Cs and 83-105 Bq for60Co. The International Commission on Radiological Protection dose coefficients for members of the public were used to calculate the committed effective doses (CEDs) corresponding to the MDAs, showing that CEDs down to a fewµSv can be estimated with this gamma camera for the inhalation of aerosols of absorption type M. The distant sitting geometry was used to enable the estimation of higher contamination levels, and a hypothetical maximum CED was calculated. This was shown to be 256-2000 mSv, depending on the radionuclide and phantom size. However, further investigations are needed into the dead time losses for higher activity levels for the radionuclides studied. The results show that the use of gamma cameras for radiological triage and, in some cases, to estimate the internal activity of relevant radionuclides in radiological and nuclear events, is feasible.


Assuntos
Defesa Civil , Câmaras gama , Humanos , Calibragem , Radioisótopos de Césio , Tomografia Computadorizada por Raios X