Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31.588
Filtrar
1.
Spectrochim Acta A Mol Biomol Spectrosc ; 324: 124950, 2025 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-39133976

RESUMO

Low fluorescence under visible light excitation and catalytic activity limit many applications of graphene quantum dots in optical detection, biosensing, catalysis and biomedical. The paper reports design and synthesis of histidine, serine and folic acid-functionalized and boron and iron-doped graphene quantum dot (Fe/B-GQD-HSF). The Fe/B-GQD-HSF shows excellent fluorescence behavior and peroxidase-like activity. Excitation of 330 nm ultraviolet light produces the strongest blue fluorescence and excitation of 480 nm visible light produces the strongest yellow fluorescence. The specific activity reaches 92.67 U g-1, which is higher than that of other graphene quantum dots. The Fe/B-GQD-HSF can catalyze oxidation of 3,3',5,5'-tetramethylbenzidine with H2O2 to form blue compound. Based on this, it was used for colorimetric and fluorescence detection of H2O2. The absorbance at 652 nm linearly increases with the increase of H2O2 concentration between 0.5 and 100 µM with detection limit of 0.43 µM. The fluorescence signal linearly decreases with the increase of H2O2 concentration between 0.05 and 100 µM with detection limit of 0.035 µM. The analytical method has been satisfactorily applied in detection of H2O2 in food. The study also paves one way for design and synthesis of functional graphene quantum dots with ideal fluorescence behavior and catalytic activity.


Assuntos
Boro , Colorimetria , Ácido Fólico , Grafite , Histidina , Peróxido de Hidrogênio , Ferro , Pontos Quânticos , Serina , Pontos Quânticos/química , Grafite/química , Peróxido de Hidrogênio/análise , Peróxido de Hidrogênio/química , Colorimetria/métodos , Ácido Fólico/análise , Ácido Fólico/química , Ferro/análise , Ferro/química , Boro/química , Histidina/análise , Histidina/química , Serina/análise , Serina/química , Espectrometria de Fluorescência/métodos , Limite de Detecção , Análise de Alimentos/métodos , Peroxidase/química , Peroxidase/metabolismo , Catálise
2.
Spectrochim Acta A Mol Biomol Spectrosc ; 324: 124914, 2025 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-39137711

RESUMO

Lead (Pb) is a heavy metal known for its adverse effects on both human health and the environment. In recent years, the industrial utilization of Pb2+ has surged, underscoring the imperative need for efficient measurement methods. In this study, a rapid and simple photochemical method was used to synthesize thioglycolic acid (TGA)-stabilized CdTe/ZnSe core-shell quantum dots (QDs). These CdTe/ZnSe QDs emit vibrant green fluorescence and exhibit remarkable quenching in the presence of Pb2+ ions. This property enables the development of an on-site on/off sensor without the necessity of additional modifications. The proposed sensor possesses an outstanding sensitivity to Pb2+, with a detection limit and linear range of 31.8 nM and 50 nM-10 µM, respectively. Importantly, the selectivity of this fluorescence-based sensor was validated by analyzing various positively and negatively charged ions. Furthermore, the developed sensor showed reliable performance against real river, agricultural, and tap water, as confirmed by Inductively Coupled Plasma (ICP) analysis. Additionally, CdTe/ZnSe QDs immobilized on glass slides were successfully employed for on-site water sample analysis, providing a versatile solution for environmental monitoring.

3.
Spectrochim Acta A Mol Biomol Spectrosc ; 324: 124958, 2025 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-39146627

RESUMO

Vanillin is a commonly used synthetic flavoring agent in daily life. However, excessive intake of vanillin may pose risks to human health. Therefore, there is an urgent need for rapid and sensitive detection methods for vanillin. In this study, we developed a fluorescent sensor based on Cd-MOF for the sensitive and selective recognition of vanillin. The presence of vanillin leads to significant fluorescence quenching of Cd-MOF due to competitive absorption and photoinduced electron transfer (PET). The limit of detection was determined to be 39.6 nM, which is the lowest-among the reported fluorescent probes. The sensor was successfully applied for the detection of vanillin in real samples such as powdered milk and milk, with a recovery rate ranging from 96.88 % to 104.83 %. Furthermore, by immobilizing the Cd-MOF probe into a polyvinyl alcohol (PVA) film, we achieved a portable and visual detection composite materials for vanillin.


Assuntos
Benzaldeídos , Estruturas Metalorgânicas , Leite , Espectrometria de Fluorescência , Benzaldeídos/análise , Benzaldeídos/química , Leite/química , Animais , Espectrometria de Fluorescência/métodos , Estruturas Metalorgânicas/química , Pós , Corantes Fluorescentes/química , Limite de Detecção , Cádmio/análise
4.
Spectrochim Acta A Mol Biomol Spectrosc ; 324: 124965, 2025 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-39153345

RESUMO

AFB1 is a harmful substance that can be found in agricultural products and can seriously affect human health, even in trace amounts. Therefore, monitoring AFB1 levels to ensure food safety and protect public health is crucial. New, highly reliable, selective, and rapid detection methods are needed to achieve this goal. Our work involves the development of a polymeric membrane sensor using radical polymerization that can accurately detect AFB1. Various spectroscopic techniques (Fourier transform infrared spectroscopy (FT-IR) and scanning electron microscopy (SEM)) were used to obtain information about the structural and morphological properties of the prepared sensor. The sensor displayed fluorescence selectively responsive to AFB1 at the excitation wavelength of 376 nm and emission wavelength of 423 nm. The polymeric fluorescence sensor showed good sensitivity and a wide linear range from 9.61 × 10-10 and 9.61 × 10-9 mol/L for AFB1quantification. The limit of detection (LOD) is as low as 3.84 × 10-10 mol/L for AFB1. Other mycotoxins, such as aflatoxin B2 and aflatoxin G1, did not interfere with the sensor's high selectivity towards AFB1. To test the sensor's effectiveness in detecting AFB1 in real samples, three different grain samples - peanuts, hazelnut butter, and peanuts with a sauce known to contain AFB1 - were utilized. The results were satisfactory and demonstrated that the sensor can be successfully employed in real samples, with an error range of 0.43 % to 12.10 %.


Assuntos
Aflatoxina B1 , Limite de Detecção , Espectrometria de Fluorescência , beta-Ciclodextrinas , Aflatoxina B1/análise , Espectrometria de Fluorescência/métodos , beta-Ciclodextrinas/química , Espectroscopia de Infravermelho com Transformada de Fourier , Contaminação de Alimentos/análise , Grão Comestível/química , Polímeros/química
5.
Spectrochim Acta A Mol Biomol Spectrosc ; 324: 124989, 2025 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-39154403

RESUMO

A newly developed 2H5MA-MOF sensor by covalently linking NH2-MIL-53(Al) with 2'-Hydroxy-5'-methylacetophenon, designed for highly sensitive and selective detection of Cd2+ ions using fluorometric methods. Detailed structural and morphological analyses confirmed the sensor's unique properties. It demonstrated an impressive linear detection range from 0 to 2 ppm, with an exceptionally low detection limit of 5.77 × 10-2 ppm and a quantification limit of 1.75 × 10-1 ppm, indicating its high sensitivity (R2 = 0.9996). The sensor also responded quickly, detecting Cd2+ within just 30 s at pH 4. We successfully tested it on real samples of tap water and human blood plasma, achieving recovery rates between 96 % and 104 %. The accuracy of these findings was further validated by comparison with ICP-OES. Overall, the 2H5MA-MOF sensor shows great potential for fast, ultra-sensitive, and reliable detection of Cd2+ ions, making it a promising tool for environmental and biomedical applications.


Assuntos
Cádmio , Água Potável , Limite de Detecção , Estruturas Metalorgânicas , Cádmio/sangue , Cádmio/análise , Humanos , Estruturas Metalorgânicas/química , Água Potável/análise , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/sangue , Íons/sangue , Concentração de Íons de Hidrogênio
6.
Spectrochim Acta A Mol Biomol Spectrosc ; 324: 124951, 2025 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-39163770

RESUMO

Glycerol is an important biological molecule, but no facile and on-site fluorescence sensor for detecting glycerol has been reported up to now. In this work, the organic fluorescent sensor for glycerol was prepared based on hydrazine-bridged bis-tetraphenylimidazole (HBT), which exhibited an excellent "turn-on" blue fluorescence response in detecting glycerol for the first time. The good sensing selectivity for glycerol among all kinds of organic molecules and ions was confirmed with the low detection limitation (LOD=0.48 µM). The sensing mechanism was proposed as that the photo-induced electron transfer process between the lone pair electrons of the Schiff group and the tetraphenylimidazole moiety was interrupted by the multiple hydrogen-bond action between glycerol and HBT. The sensing ability of HBT for glycerol was successfully used for the detection of glycerol in test paper and real samples (glycerine enema and aloe vera gel), demonstrating the good potential for simple, rapid and in-situ detection of glycerol in daily life.

7.
Spectrochim Acta A Mol Biomol Spectrosc ; 324: 124982, 2025 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-39173318

RESUMO

Imine based positional isomers (8E)-N-(4-((E)-(perfluorophenylimino)methyl)benzylidene)-2,3,4,5,6-pentafluorobenzenamine, L and (10E)-N-(3-(E-Perfluorophenylimino)methyl)benzylidene)-2,3,4,5,6-pentafluorobenzenamine, L1 have been designed, and synthesized by functionalizing two electron deficient aromatic moieties at the para-para'/ortho-ortho' positions in the phenyl core of the L and L1 respectively. The responses of L and L1 towards various anionic species are examined. The positional isomers L and L1 differs not only by showing distinguishable color change upon addition of anions but also differentiates themselves by the way of self-assembling together upon binding with cyanide anion. The naked-eye colorimetric experiments, UV-Vis, Nuclear Magnetic Resonance, and Infra-Red spectroscopic analyses reveal that the isomer L binds fluoride anion through 2:1 stoichiometry ratio. Unlike fluoride complex, the isomer L form aggregates while binding with cyanide ion. On the other hand, isomer L1 does not show any instant color change upon additions of any anion. Interestingly, after thirty minutes, only the color of the cyanide complex is turned into dark brown. While analyzing the spectroscopic results of cyanide complex of L1, it is found that the cyanide complex begins to decompose and finally it is completely decomposed within 30 min. This unprecedented phenomenon about the colorimetric sensing of cyanide and destruction of cyanide complex with respect to time has not been reported in the literature yet. To the best of our knowledge this is the first example of study of sensing controlling the selectivity, mode of binding, self-aggregating and degradation properties of anionic complexes under the influence of positional isomeric effects. This present investigation provides simple and effective strategy to construct the sensor molecules with tunable binding properties in terms of easy to prepare as well as easy to use as a colorimetric sensor. _____________________________________________________________________________________________________.

8.
Methods Mol Biol ; 2854: 107-115, 2025.
Artigo em Inglês | MEDLINE | ID: mdl-39192123

RESUMO

The innate immune system plays a pivotal role in pathogen recognition and the initiation of innate immune responses through its Pathogen Recognition Receptors (PRRs), which detect Pathogen-Associated Molecular Patterns (PAMPs). Nucleic acids, including RNA and DNA, are recognized as particularly significant PAMPs, especially in the context of viral pathogens. During RNA virus infections, specific sequences in the viral RNA mark it as non-self, enabling host recognition through interactions with RNA sensors, thereby triggering innate immunity. Given that some of the most lethal viruses are RNA viruses, they pose a severe threat to human and animal health. Therefore, understanding the immunobiology of RNA PRRs is crucial for controlling pathogen infections, particularly RNA virus infections. In this chapter, we will introduce a "pull-down" method for identifying RIG-I-like receptors, related RNA helicases, Toll-like receptors, and other RNA sensors.


Assuntos
Imunidade Inata , RNA Viral , Receptores de Reconhecimento de Padrão , Humanos , RNA Viral/genética , RNA Viral/imunologia , Receptores de Reconhecimento de Padrão/metabolismo , Receptores de Reconhecimento de Padrão/imunologia , Animais , Receptores Toll-Like/metabolismo , Receptores Toll-Like/imunologia , Receptores Toll-Like/genética , Vírus de RNA/imunologia , Vírus de RNA/genética , Interações Hospedeiro-Patógeno/imunologia , Proteína DEAD-box 58/metabolismo , Proteína DEAD-box 58/genética , Proteína DEAD-box 58/imunologia , Moléculas com Motivos Associados a Patógenos/imunologia , Moléculas com Motivos Associados a Patógenos/metabolismo , Infecções por Vírus de RNA/imunologia , Infecções por Vírus de RNA/virologia
9.
Methods Mol Biol ; 2854: 265-282, 2025.
Artigo em Inglês | MEDLINE | ID: mdl-39192136

RESUMO

Protein kinase R (PKR), a key double-stranded RNA (dsRNA)-activated sensor, is pivotal for cellular responses to diverse stimuli. This protocol delineates a comprehensive methodological framework employing single luciferase assays, yeast assays, immunoblot assays, and quantitative PCR (qPCR) to discern and validate PKR activities and their downstream impacts on NF-κB-activating signaling pathways. These methodologies furnish a systematic approach to unraveling the role of PKR as a dsRNA sensor and effector in antiviral innate immunity, enabling in-depth analyses of dsRNA sensor activities.


Assuntos
Imunidade Inata , RNA de Cadeia Dupla , eIF-2 Quinase , eIF-2 Quinase/metabolismo , eIF-2 Quinase/genética , RNA de Cadeia Dupla/imunologia , RNA de Cadeia Dupla/genética , Humanos , NF-kappa B/metabolismo , Transdução de Sinais , Animais
10.
Spectrochim Acta A Mol Biomol Spectrosc ; 324: 125039, 2025 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-39197211

RESUMO

A ratiometric nanosensor was developed for detecting methyl orange (MO) based on down/up-conversion luminescence achieved by a triplet-triplet annihilation upconversion luminescence (TTA-UCL) system. The probe, utilizing sensitizer and annihilator fluorophores encapsulated in nanomicelles, demonstrated high sensitivity and selectivity for MO detection. The energy transfer from UCL to MO endowed the sensor with responsive capabilities. The unaffected triplet-triplet energy transfer process maintained the phosphorescence signal constant, serving as a reference to construct the ratiometric sensor along with the UCL signal. Additionally, a smartphone-assisted colorimetric detection method was also developed based on the ratiometric sensor, enabling rapid and convenient detection of MO without the need for a spectrometer. The performance of the nanosensor in real water samples confirmed its potential for practical environmental applications.

11.
Food Chem ; 462: 140693, 2025 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-39208722

RESUMO

A rapid photoelectrochemical (PEC) sensor was constructed for nitrite detection in food based on the one-step chemical etching strategy of BiOCl/Zn0.5Cd0.5S (BOC/ZCS) nanocomposites by nitrite. BOC/ZCS heterojunction was prepared by a simple coprecipitation method, and it was found that BOC/ZCS showed significant photoelectrochemical (PEC) activity. The results of this study confirmed that the decrease in the photocurrent of the sensor was linked to the etching of ZCS by nitrite under acidic conditions. Under optimized conditions, the BOC/ZCS-based PEC sensor showed good analytical properties for detecting nitrite, with linear ranges of 1-100 µM and 100-600 µM. The detection limit of the sensor was 0.41 µM (S/N = 3). Excellent repeatability, reproducibility, low background noise, and immunity to interference were demonstrated using the proposed system, and satisfactory results were achieved for the nitrite assay using real samples. These results demonstrate a new method for nitrite detection developed using the proposed PEC sensor.


Assuntos
Técnicas Eletroquímicas , Limite de Detecção , Nitritos , Nitritos/análise , Técnicas Eletroquímicas/instrumentação , Bismuto/química , Zinco/química , Zinco/análise , Nanocompostos/química , Processos Fotoquímicos , Contaminação de Alimentos/análise
12.
Food Chem ; 462: 140947, 2025 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-39208736

RESUMO

Excess nitrites are potentially threatening to human health, so it is urgent to develop accurate and sensitive methods. The development of sensors can provide early warning of possible hazards and alert people to protect public health. This work presents an NiSx@MoS2-composite with excellent electrochemical activity, representing a key finding for highly sensitive NO2- detection and sensor development. With the assistance of NiSx@MoS2, this electrochemical sensor has excellent quantitative detection performance. It has a wide detection range (0.0001-0.0020 mg/mL) and a low detection limit (1.863*10-5 mg/mL) for NO2-. This electrochemical sensor maintains excellent specificity among numerous interferences, and it completes the accurate detection of different real food samples. Pleasingly, the electrochemical sensor has satisfactory repeatability stability, and potential for practical applications. It would demonstrate tremendous potential in scientific dietary guidance, food safety detection and other fields.


Assuntos
Dissulfetos , Técnicas Eletroquímicas , Limite de Detecção , Molibdênio , Molibdênio/química , Técnicas Eletroquímicas/instrumentação , Dissulfetos/química , Nitritos/análise , Contaminação de Alimentos/análise
13.
Food Chem ; 462: 140964, 2025 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-39213972

RESUMO

The objective of this study was to develop and validate a novel microfluidic paper-based analytical device (µPADpH) for determining the pH levels in foods. Anthocyanins from red cabbage aqueous extract (RCAE) were used as its analytical sensor. Whatman No. 1 filter paper was the most suitable for the device due to its porosity and fiber organization, which allows for maximum color intensity and minimal color heterogeneity of the RCAE in the detection zone of the µPADpH. To ensure the color stability of the RCAE for commercial use of the µPADpH, gum arabic was added. The geometric design of the µPADpH, including the channel length and separation zone diameter, was systematically optimized using colored food. The validation showed that the µPADpH did not differ from the pH meter when analyzing natural foods. However, certain additives in processed foods were found to increase the pH values.


Assuntos
Antocianinas , Brassica , Goma Arábica , Antocianinas/química , Antocianinas/análise , Brassica/química , Concentração de Íons de Hidrogênio , Goma Arábica/química , Papel , Técnicas Analíticas Microfluídicas/instrumentação
14.
J Colloid Interface Sci ; 677(Pt A): 273-281, 2025 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-39094488

RESUMO

Wearable electronics based on conductive hydrogels (CHs) offer remarkable flexibility, conductivity, and versatility. However, the flexibility, adhesiveness, and conductivity of traditional CHs deteriorate when they freeze, thereby limiting their utility in challenging environments. In this work, we introduce a PHEA-NaSS/G hydrogel that can be conveniently fabricated into a freeze-resistant conductive hydrogel by weakening the hydrogen bonds between water molecules. This is achieved through the synergistic interaction between the charged polar end group (-SO3-) and the glycerol-water binary solvent system. The conductive hydrogel is simultaneously endowed with tunable mechanical properties and conductive pathways by the modulation caused by varying material compositions. Due to the uniform interconnectivity of the network structure resulting from strong intermolecular interactions and the enhancement effect of charged polar end-groups, the resulting hydrogel exhibits 174 kPa tensile strength, 2105 % tensile strain, and excellent sensing ability (GF = 2.86, response time: 121 ms), and the sensor is well suited for repeatable and stable monitoring of human motion. Additionally, using the Full Convolutional Network (FCN) algorithm, the sensor can be used to recognize English letter handwriting with an accuracy of 96.4 %. This hydrogel strain sensor provides a simple method for creating multi-functional electronic devices, with significant potential in the fields of multifunctional electronics such as soft robotics, health monitoring, and human-computer interaction.

15.
J Environ Sci (China) ; 148: 139-150, 2025 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-39095153

RESUMO

Herein, a modified screen printed carbon electrode (SPCE) based on a composite material, graphene oxide-gold nanoparticles (GO-AuNPs), and poly(3-aminobenzoic acid)(P3ABA) for the detection of paraquat (PQ) is introduced. The modified electrode was fabricated by drop casting of the GO-AuNPs, followed by electropolymerization of 3-aminobenzoic acid to achieve SPCE/GO-AuNPs/P3ABA. The morphology and microstructural characteristics of the modified electrodes were revealed by scanning electron microscopy (SEM) for each step of modification. The composite GO-AuNPs can provide high surface area and enhance electroconductivity of the electrode. In addition, the presence of negatively charged P3ABA notably improved PQ adsorption and electron transfer rate, which stimulate redox reaction on the modified electrode, thus improving the sensitivity of PQ analysis. The SPCE/GO-AuNPs/P3ABA offered a wide linear range of PQ determination (10-9-10-4 mol/L) and low limit of detection (LOD) of 0.45 × 10-9 mol/L or 0.116 µg/L, which is far below international safety regulations. The modified electrode showed minimum interference effect with percent recovery ranging from 96.5% to 116.1% after addition of other herbicides, pesticides, metal ions, and additives. The stability of the SPCE/GO-AuNPs/P3ABA was evaluated, and the results indicated negligible changes in the detection signal over 9 weeks. Moreover, this modified electrode was successfully implemented for PQ analysis in both natural and tapped water with high accuracy.


Assuntos
Técnicas Eletroquímicas , Eletrodos , Ouro , Grafite , Nanopartículas Metálicas , Paraquat , Grafite/química , Paraquat/análise , Ouro/química , Nanopartículas Metálicas/química , Técnicas Eletroquímicas/métodos , Limite de Detecção , Carbono/química , Poluentes Químicos da Água/análise , Herbicidas/análise
16.
Food Chem ; 462: 141063, 2025 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-39226640

RESUMO

In this research, the TT-COF(Fe)@NH2-CNTs was innovatively prepared through a post-modification synthetic process functionalized TT-COF@NH2-CNTs with active site (Fe), where TT-COF@NH2-CNTs was prepared via a one-pot strategy using 5,10,15,20-tetrakis (para-aminophenyl) porphyrin (TTAP), 2,3,6,7-tetra (4-formylphenyl) tetrathiafulvalene (TTF) and aminated carbon nanotubes (NH2-CNTs) as raw materials. The complex TT-COF(Fe)@NH2-CNTs material possessed porous structures, outstanding conductivity and rich catalytic sites. Thus, it can be adopted to construct electrochemical sensor with glassy carbon electrode (GCE). The TT-COF(Fe)@NH2-CNTs/GCE can selectively detect luteolin (Lu) with a wide linear plot ranging from 0.005 to 3 µM and a low limit of detection (LOD) of 1.45 nM (S/N = 3). The Lu residues in carrot samples were determined using TT-COF(Fe)@NH2-CNTs sensor and UV-visible (UV-Vis) approach. This TT-COF(Fe)@NH2-CNTs/GCE sensor paves the way for the quantification of Lu through a cost-efficient and sensitive electrochemical approach, which can make a significant step in the sensing field based on crystalline COFs.


Assuntos
Técnicas Eletroquímicas , Luteolina , Nanotubos de Carbono , Nanotubos de Carbono/química , Luteolina/química , Luteolina/análise , Técnicas Eletroquímicas/instrumentação , Limite de Detecção , Estruturas Metalorgânicas/química , Contaminação de Alimentos/análise , Domínio Catalítico
17.
ACS Sens ; 2024 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-39350515

RESUMO

Transition metal oxide semiconductors have great potential for use in H2 sensors, but in recent years, the strange phenomena about gas-sensitive performance associated with their special properties have been more widely discussed in research. In some cases, the resistance of transition metal oxide gas sensors will emerge with some changes contrary to their intrinsic semiconductor characteristics, especially in gas sensor research of WO3. Based on the hydrothermal synthesis of WO3, our work focuses on the abnormal change of tungsten oxide resistance to different gases at low temperature (80-200 °C) and high temperature (above 200 °C). Through in situ FT-IR and in situ XPS, combined with density functional theory calculations, a new reasonable explanation of WO3 is proposed for the abnormal resistance change caused by temperature and the strange response due to gas concentration. The occurrence of these findings can be attributed to the synergistic effect resulting from the presence of two contributing factors. One of them is attributed to the alteration in the surface valence state of WO3 induced by gas, resulting in the reduction of W6+. The other one is due to the reaction between gas and adsorbed oxygen on the surface of WO3. This work presents a novel and rational concept for addressing the reaction mechanism between gas and transition metal oxide semiconductors, thereby paving the way for the development of highly efficient gas sensors based on transition metal oxide semiconductors.

18.
J Texture Stud ; 55(5): e12868, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39350627

RESUMO

This study investigates the forces exerted on organs during swallowing, specifically focusing on identifying forces other than those resulting from direct organ contact. Using a swallowing simulator based on the moving particle method, we simulated the swallowing process of healthy individuals upon the ingestion of thickened foods, which were simulated as shear-thinning flow without yield stress. We extracted the resultant force vectors acting on the organs and shape of the bolus at each time interval. The simulation results confirmed that the bolus originates from tongue movement and is transferred between the oral cavity and pharynx, with each organ's coordinated movements with the tongue occurring at their respective positions, as indicated by the balance of the resultant force vectors. Utilizing the information about the resultant force vectors obtained through simulations, we calculated the physical parameters of impulse, energy, and power. The variations in these physical parameters were aligned with the behaviors of both the biological system and the food bolus during swallowing. The force values calculated from the simulations closely approximate the theoretical values. Furthermore, the forces calculated from the simulations were relatively smaller than the force values derived from pressure information, such as that from high-resolution manometry and tongue pressure sensors. This difference can be attributed to the simulations extracting only the forces exerted on the organ by the food bolus. Force information on organs has the potential to provide a new interpretation of conventional mechanical indicators such as manometry and tongue pressure sensors.


Assuntos
Simulação por Computador , Deglutição , Boca , Faringe , Língua , Deglutição/fisiologia , Humanos , Língua/fisiologia , Faringe/fisiologia , Boca/fisiologia , Alimentos , Modelos Biológicos , Pressão , Fenômenos Biomecânicos , Manometria/métodos , Adulto , Masculino
19.
ACS Nano ; 2024 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-39356285

RESUMO

Despite substantial progress in the diagnosis of jaundice/hyperbilirubinemia as the most common disease and cause of hospitalization of newborns, on the eve of Industry/Healthcare 5.0, the development of accurate and reliable wearable diagnostic sensors for noninvasive smart monitoring of bilirubin (BIL) is still in high demand. Aiming to fabricate a smart wearable sensor for early diagnosis of neonatal jaundice and its therapeutic monitoring, we here report a fluorescent dermal nanotattoo that further coupled with an IoT-integrated wearable optoelectronic reader for minimally invasive, continuous, and real-time monitoring of BIL in interstitial fluid. Selective recovery of quenched fluorescence of the dermal tattoo sensor, composed of biocompatible dissolving/hydrogel microneedles loaded with fluorescent carbon quantum dots, upon blue light exposure used for jaundice phototherapy was utilized for highly selective BIL sensing. The fascinating features of our developed smart wearable tattoo sensor and its successful results with high correlation with blood BIL results make it a highly promising sensor for easy, minimally invasive, reliable, and smart eDiagnostics and continuous therapeutic eMonitoring of jaundice and other BIL-induced diseases at the point of care. We envision that the developed nanotattoo sensing bioplatform will inspire the development of future smart tattoo sensors in various diagnostic and monitoring scenarios.

20.
J Fluoresc ; 2024 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-39356390

RESUMO

The number of "turn-on" fluorescent probes for Cu2+ is relatively limited, and interference from other metal cations presents a significant challenge for these sensors. In this study, we synthesized and characterized a rhodamine B-based sensor, designated as RBHP, using 1-phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP) and rhodamine B hydrazide. Selectivity, sensitivity, solvent effects, water content, and pH of RBHP in relation to Cu²âº were conducted. RBHP exhibited an exceptionally low fluorescence background signal in acetonitrile and demonstrated a "turn-on" fluorescent response to Cu²âº. The PMBP-based acylhydrazone moiety and acetonitrile as the detection solvent are crucial for the selective detection. RBHP shows potential as a highly selective and sensitive fluorescent sensor for Cu2+.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...