RESUMO
OBJECTIVES: (1) To determine whether perception of pharyngeal residue severity differs by view plane on videofluoroscopy. (2) To explore whether the Bolus Clearance Ratio (BCR) can be reliably applied in the anterior-posterior (AP) plane. (3) To investigate the relationship between perception of residue severity and BCR measures across view planes. METHODS: Images of the same bolus condition in lateral and AP were rated using a simple 5-point ordinal descriptive scale (none, trace, mild, moderate, severe) by 225 speech-language pathologists via electronic survey. BCR measures were obtained for the same set of images from four trained raters. Wilcoxon signed-rank tests and cumulative mixed modeling were used to compare ratings by plane. BCR reliability was calculated using intraclass correlation coefficients. Perceptual ratings were compared with BCR measures using Spearman correlations. RESULT: (1) Perception of residue severity was not consistent across plane in 9/10 image pairs (p < 0.05), with a significant fixed effect of plane on severity rating (ß = 0.41; z = 7.27; p < 0.001). The directionality of differences varied by case. (2) Inter-rater reliability for BCR measures was good across lateral (intraclass correlation coefficient [ICC] = 0.82) and AP (ICC = 0.87) planes, with superior intra-rater reliability in AP (lateral ICC = 0.85; AP ICC = 0.98). (3) There was a strong positive correlation between perceptual ratings and BCR measures in both planes. CONCLUSIONS: Perception of pharyngeal residue severity differs between lateral and AP planes with inconsistent directionality raising important questions about the clinical implications of single plane studies. The BCR shows good-excellent reliability and strong correlation with perception across planes, offering a promising method for cross-plane quantification. LEVEL OF EVIDENCE: Level III, diagnostic study with a gold standard Laryngoscope, 2024.
RESUMO
PURPOSE: The purpose of this study was to identify the temporal and spatial parameters of videofluoroscopic swallowing study (VFSS) that could predict the recovery of swallowing function in subacute stroke patients. METHODS: We included 102 patients who were admitted to the Department of Rehabilitation Medicine between 2019 and 2022. Patients were classified into good and poor prognosis groups according to whether they had restored prestroke swallowing function or were able to consume sufficient nutrition via oral feeding to meet their body's needs. Univariate and multivariate regression analyses were used to identify the predictors. Calibration and discrimination were tested using the Hosmer-Lemeshow test and area under the curve (AUC), respectively. RESULTS: Of the 102 included patients, 51 had a good prognosis for swallowing function within 6 months of onset. The final multivariate regression model included three significant factors: laryngeal closure duration (LCD) (OR: 0.998; 95% CI: 0.996-0.999; p < 0.05), maximum width of the upper esophageal sphincter opening (MWUESO) (OR: 1.251; 95% CI: 1.073-1.458; p < 0.05), and pharyngeal residual grade (PRG) (p < 0.05). The shorter LCD and larger MWUESO were positive predictors of good swallowing function outcomes, while higher PRG was a negative predictor of good outcomes. The AUC for PRG, MWUESO, and LCD were 0.767 (p < 0.05), 0.738 (p < 0.05), and 0.681 (p < 0.05), respectively. CONCLUSION: Identifying prognostic factors for the recovery of swallowing function in patients with poststroke dysphagia is essential for developing treatment strategies. The findings of this study may provide an important reference for developing appropriate therapeutic interventions to promote the recovery of swallowing function in stroke patients.
Assuntos
Transtornos de Deglutição , Deglutição , Recuperação de Função Fisiológica , Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Acidente Vascular Cerebral/fisiopatologia , Acidente Vascular Cerebral/complicações , Fluoroscopia/métodos , Recuperação de Função Fisiológica/fisiologia , Transtornos de Deglutição/fisiopatologia , Transtornos de Deglutição/etiologia , Transtornos de Deglutição/reabilitação , Transtornos de Deglutição/diagnóstico por imagem , Deglutição/fisiologia , Prognóstico , Gravação em Vídeo , Reabilitação do Acidente Vascular Cerebral/métodos , Idoso de 80 Anos ou maisRESUMO
Speech-language pathologists need to accurately identify structures/landmarks on swallow imaging. Foundational learning begins in graduate training. This study aimed to determine graduate student accuracy at identifying anatomical structures/landmarks during swallow evaluations and to determine if accuracy was predicted by type of imaging, anatomical structure, case type (i.e., normal/abnormal). Researchers recruited first-year graduate speech-language pathology students. Each participant reviewed five static images from lateral radiographic swallow studies and five static images from endoscopic swallow studies across 10 cases. Participants identified key anatomic structures and landmarks by clicking on the structure/landmark within a web-based platform. Two experienced speech-language pathologists reviewed and coded participant responses for accuracy. Sixteen graduate speech-language pathology students participated in a within-subjects design. Overall participant accuracy in identification of structure/landmarks was 69% (range 46%-88%). Binomial logistic regression was performed to study the effects of anatomical structure, case type (i.e., normal/abnormal), and image type on likelihood of participant accuracy in identifying anatomical structures (X2(4) = 143.65, p < 0.001). Only anatomical structure was statistically significant (X2(4) = 187.729, p < 0.001). The model explained 23.2% (Nagelkerke's R squared) of the variance in accuracy and correctly classified 78.4% of cases. Sensitivity was 92.1%, specificity was 47.3%, positive predictive value was 79.84%, and negative predictive value was 72.50%. The area under the ROC curve was 0.754, 95% CI [0.716, 0.791]. Graduate student's ability to correctly identify structures/landmarks overall was lower than desired and accuracy varied per structure. Results have implications for improving graduate student training for identification of structures/landmarks on swallow imaging.
RESUMO
Thousands of rescued harbor seals (Phoca vitulina) require rehabilitation worldwide. Many require resource intensive gavage feeding due to abandonment soon after birth. Little is known about seal swallowing, therefore, our primary objective was to determine the feasibility of conducting videofluoroscopic swallowing studies (VFS) on seal pups prior to their release. Secondarily, we propose swallowing phase descriptions. We adapted a VFS approach used in humans and our feasibility parameters included: bolus detection and consumption, and number of analyzable swallowing events. Unrestrained seals were imaged in a dry environment using a Siemens mobile c-arm fluoroscopy unit. Oral boluses were thawed herring injected with liquid barium suspension (105% w/v). Two independent raters described swallows using a standardized approach with results summarized descriptively. We successfully completed freely-behaving VFS with two infant seals (1 male: 8 wks, 3 d; 1 female: 5 wks, 3 d). Both consumed five boluses with six fully analyzable swallowing events. We describe four swallow phases: preparatory, prehension, oropharyngeal and esophageal. Airway protection likely occurs in two ways: (1) during the preparatory phase through modified corniculate cartilage contact with the glottis and (2) with soft palate contact to the base of tongue prior to swallow initiation. We have conducted a unique VFS approach on rehabilitated seals, prior to their release. We have described airway protection and suggest that swallowing is initiated earlier in the feeding process than described previously. This protocol success will afford: (1) collection of normative swallowing data, and (2) future knowledge translation from humans to seals.
RESUMO
Introduction: Swallowing impairment is a crucial issue that can lead to aspiration, pneumonia, and malnutrition. Animal models are useful to reveal pathophysiology and to facilitate development of new treatments for dysphagia caused by many diseases. The present study aimed to develop a new dysphagia model with reduced pharyngeal constriction during pharyngeal swallowing. Methods: We analyzed the dynamics of pharyngeal swallowing over time with the pharyngeal branches of the vagus nerve (Ph-X) bilaterally or unilaterally transected, using videofluoroscopic assessment of swallowing in guinea pigs. We also evaluated the detailed anatomy of the pharyngeal constrictor muscles after the denervation. Results: Videofluoroscopic examination of swallowing showed a significant increase in the pharyngeal area during swallowing after bilateral and unilateral sectioning of the Ph-X. The videofluoroscopy also showed significantly higher pharyngeal transit duration for bilateral and unilateral section groups. The thyropharyngeal muscle on the sectioned side was significantly thinner than that on the intact side. In contrast, the thickness of the cricopharyngeal muscles on the sectioned and intact sides were not significantly different. The mean thickness of the bilateral thyropharyngeal muscles showed a linear correlation to the pharyngeal area and pharyngeal transit duration. Discussion: Data obtained in this study suggest that denervation of the Ph-X could influence the strength of pharyngeal contraction during pharyngeal swallowing in relation to thickness of the pharyngeal constrictor muscles, resulting in a decrease in bolus speed. This experimental model may provide essential information (1) for the development of treatments for pharyngeal dysphagia and (2) on the mechanisms related to the recovery process, reinnervation, and nerve regeneration following injury and swallowing impairment possibly caused by medullary stroke, neuromuscular disease, or surgical damage from head and neck cancer.
RESUMO
Background: Dysphagia is commonly evaluated using videofluoroscopy (VFS). As its ratings are usually subjective normal-abnormal ratings, objective measurements have been developed. We compared the inter-rater reliability of the usual VFS ratings to the objective measurement VFS ratings and evaluated their clinical relevance. Methods: Two blinded raters analyzed the subjective normal-abnormal ratings of 77 patients' VFS. Two other blinded raters analyzed the objective measurements of pharyngeal aerated area with bolus held in the oral cavity (PAhold), the pharyngeal area of residual bolus during swallowing (PAmax), the pharyngeal constriction ratio (PCR), the maximum pharyngoesophageal segment opening (PESmax), pharyngoesophageal segment opening duration (POD), airway closure duration (ACD), and total pharyngeal transit time (TPT). We evaluated the inter-rater agreement in the subjective ratings and the objective measurements. Clinical utility analysis compared the measurements with the VFS findings of pharyngeal phase abnormality, penetration/aspiration, and cricopharyngeal relaxation. Results: In the pharyngeal findings, the subjective analysis inter-rater agreement was mainly moderate to strong. The strongest agreements were on the pharyngeal residues and penetration/aspiration findings. The objective measurements had fair to good inter-rater agreement. Clinical utility analysis found statistically significant connections between TPT and pharyngeal phase abnormality, normal PCR and lack of penetration/aspiration, and normal PESmax and normal cricopharyngeal relaxation. Conclusions: The subjective analysis had moderate to strong inter-rater agreement in the pharyngeal VFS findings, especially concerning pharyngeal residues and penetration/aspiration detection, reflecting the efficacy and safety of swallowing. The objective measurements had fair to good inter-observer reproducibility and could thus improve the reliability of VFS diagnostics. Level of evidence: 4.
RESUMO
Clinical implementation of evidence-based practice (EBP) tools is a healthcare priority. The Dynamic Grade of Swallowing Toxicity (DIGEST) is an EBP tool developed in 2016 for videofluoroscopy in head and neck (H&N) oncology with clinical implementation as a goal. We sought to examine: (1) feasibility of clinical implementation of DIGEST in a national comprehensive cancer center, and (2) fidelity of DIGEST adoption in real-world practice. A retrospective implementation evaluation was conducted in accordance with the STARI framework. Electronic health record (EHR) databases were queried for all consecutive modified barium swallow (MBS) studies conducted at MD Anderson Cancer Center from 2016 to 2021. Implementation outcomes included: feasibility as measured by DIGEST reporting in EHR (as a marker of clinical use) and fidelity as measured by accuracy of DIGEST reporting relative to the decision-tree logic (penetration-aspiration scale [PAS], residue, and Safety [S] and Efficiency [E] grades). Contextual factors examined included year, setting, cancer type, MBS indication, and provider. 13,055 MBS were conducted by 29 providers in 7,842 unique patients across the lifespan in diverse oncology populations (69% M; age 1-96 years; 58% H&N cancer; 10% inpatient, 90% outpatient). DIGEST was reported in 12,137/13,088 exams over the 6-year implementation period representing 93% (95% CI: 93-94%) adoption in all exams and 99% (95% CI: 98-99%) of exams excluding the total laryngectomy population (n = 730). DIGEST reporting varied modestly by year, cancer type, and setting/provider (> 91% in all subgroups, p < 0.001). Accuracy of DIGEST reporting was high for overall DIGEST (incorrect SE profile 1.6%, 200/12,137), DIGEST-safety (incorrect PAS 0.4% 51/12,137) and DIGEST-efficiency (incorrect residue 1.2%, 148/12,137). Clinical implementation of DIGEST was feasible with high fidelity in a busy oncology practice across a large number of providers. Adoption of the tool across the lifespan in diverse cancer diagnoses may motivate validation beyond H&N oncology.
RESUMO
Videofluoroscopic swallowing study (VFSS), alongside flexible endoscopic evaluation of swallowing, represents the gold standard for diagnosing swallowing disorders and to determine severity, pathophysiology, and effective interventions, including texture modification. The clinical swallowing examination and assessment supplements these instrumental methods and serves as the basis for the modules of swallowing diagnostics. The adaptation of food and drink consistencies in dysphagia management has become widespread. For valid results of a VFSS with respect to confirming swallowing safety and efficiency of different liquid and food consistencies and textures, the use of uniform recipes containing radio-opaque contrast media is important. Our goal was to identify recipes that would produce consistencies that conform to the liquid and food levels of 0-7, as defined by the International Dysphagia Diet Standardization Initiative (IDDSI), with barium- and iodine-based contrast media, xanthan gum-based thickeners, and other edible components, which also show sufficient contrast on VFSS. In this study, we determined the different recipes using IDDSI testing methods and explored their radiological characteristics using a Philips MultiDiagnost Eleva fluoroscopy system and two different fluid contrast agents: barium- (Micropaque®) and iodine-based (Telebrix®). All recipes showed sufficient contrast on fluoroscopy and could be visualized in the amounts used for swallowing examinations. They were practical and easy to implement in terms of production and availability of the components. The homogeneity of the recipes diminished with higher IDDSI levels, which represent transitional food, but appeared still sufficient for fluoroscopic examination. The opacity did not significantly differ between the barium- and iodine-based contrast media.
Assuntos
Transtornos de Deglutição , Iodo , Humanos , Transtornos de Deglutição/diagnóstico , Meios de Contraste , Bário , ViscosidadeRESUMO
BACKGROUND: Modification of foods or liquids is commonly administered as part of dysphagia treatment. However, no consensus exists on the parameters for defining texture-modified food for patients with dysphagia. OBJECTIVES: The aim of this study was to evaluate the effect of food/liquid material on swallowing physiology in patients with dysphagia and to discuss the optimal food choice for direct swallowing therapy. MATERIALS AND METHODS: A total of 140 patients underwent a videofluoroscopic swallowing study using three test foods/liquids: 3 mL of mildly thick liquid (Thick liquid), jelly made of agar and polysaccharide (Jelly) and jelly made of pectin (Reset gel). Outcome measures of videofluoroscopic images, bolus transit time and hyoid movements were compared. RESULTS: The frequency of chewing movements was highest for Jelly, followed by Reset gel and Thick liquid. While the probability of oral residue was the highest for Reset gel, pharyngeal residue after swallowing was high for Thick liquid as compared to Jelly and Reset gel. Oral transit time and pharyngeal transit time for Thick liquid were significantly smaller than that for Jelly and Reset gel. Pharyngeal delay time was significantly smaller for Thick liquid than that for Jelly and Reset gel. There was no difference in hyoid elevation time and hyoid movement time among the conditions. CONCLUSION: Mildly thick liquid material may be optimal for patients with primarily oral motor function impairment and jelly, such as Reset gel, may be more suitable for patients with primarily pharyngeal motor function impairment or oral and pharyngeal coordinative motor function decline.
Assuntos
Transtornos de Deglutição , Deglutição , Humanos , Transtornos de Deglutição/fisiopatologia , Feminino , Masculino , Deglutição/fisiologia , Idoso , Pessoa de Meia-Idade , Fluoroscopia , Mastigação/fisiologia , Idoso de 80 Anos ou mais , Gravação em Vídeo , Osso Hioide/fisiopatologia , Osso Hioide/diagnóstico por imagem , Adulto , AlimentosRESUMO
BACKGROUND: Cervical sagittal alignment is crucial for distributing the head load to lower cervical segments and maintaining normal cervical spine function, but its biomechanical effect on the cervical spine was not fully elucidated. OBJECTIVE: To investigate the effect of cervical sagittal alignment on dynamic intervertebral kinematics. DESIGN: Cross-sectional study. METHODS: Healthy participants without neck pain were recruited and divided into lordosis, straight and kyphosis groups according to the C2-C7 Cobb angle at the neutral position. The anti-directional and total joint motions were extracted across 10 epochs of dynamic cervical flexion and extension movements. RESULTS: /findings: The overall anti-directional joint motion during flexion is larger in the kyphosis group when compared with the lordosis group (p = 0.021), while the range of flexion is smaller in the kyphosis group than that in the lordosis group (p = 0.017). The C2/C3 anti-directional joint motion during extension in the straight group is larger than that in the lordosis group (p = 0016). The range of extension in the kyphosis group (p < 0.001) and the straight group (p = 0.002) are larger than that in the lordosis group. The increased range of extension in the kyphosis and straight groups were mainly from the C3/C4, C4/C5, and C5/C6 joints(p < 0.05). CONCLUSION: Changes in cervical sagittal alignment alter both the quality and quantity of the individual joint motions. More adjustments are required by the cervical joints to complete neck movements with the loss of lordosis. The lordotic curvature is a relatively effort-saving mode for the cervical spine from a biomechanical perspective.
Assuntos
Vértebras Cervicais , Cifose , Lordose , Amplitude de Movimento Articular , Humanos , Vértebras Cervicais/fisiopatologia , Vértebras Cervicais/diagnóstico por imagem , Masculino , Estudos Transversais , Feminino , Fenômenos Biomecânicos , Adulto , Lordose/fisiopatologia , Lordose/diagnóstico por imagem , Amplitude de Movimento Articular/fisiologia , Cifose/fisiopatologia , Cifose/diagnóstico por imagem , Fluoroscopia/métodos , Voluntários Saudáveis , Adulto JovemRESUMO
Currently, no objective method exists to measure the extent of fibrosis in swallowing musculature in head and neck cancer (HNC) patients. We developed and psychometrically tested a method of quantifying fibrosis volume using magnetic resonance imaging (MRI). The overall aim of this study was to determine if clinical MRI is a reliable tool to measure fibrosis of the pharyngeal musculature in patients with HNC managed with RT and to assess its potential to capture changes in fibrosis over time. Eligible participants were adults with HNC treated with radiation therapy (RT) who received minimally two MRIs and videofluoroscopic swallow (VFS) studies from baseline (pre-RT) up to 1-year post-RT. Two neuroradiologists independently contoured fibrosis volume in batches from MRIs using Vitrea™. Sufficient inter-rater reliability was set at Intraclass Correlation Coefficient (ICC) > 0.75. Two speech-language pathologists independently rated VFSs for swallowing impairment using standardized scales, with discrepancies resolved by consensus. MRI and VFS scores were correlated using Spearman's rank coefficient. Participants included 42 adults (male = 33); mean age 59 (SD = 8.8). ICC (95% Confidence Interval) for fibrosis volume was 0.34 (0, 0.76) for batch one and 0.43 (0, 0.82) for batch two. Consensus meetings were held after each batch. Sufficient reliability was reached by batch three (ICC = 0.95 (0.79, 0.99)). Fibrosis volume increased significantly from 3 to 12 months (mean change = 1.28 mL (SD = 5.21), p = 0.006), as did pharyngeal impairment from baseline to 12 months (mean score change = 3.05 (SD = 3.02), p = 0.003). Fibrosis volume moderately correlated with pharyngeal impairment at 3 and 12 months (0.49, p = 0.004 and 0.59, p = 0.005, respectively). We demonstrated a reliable measure of fibrosis volume in swallowing musculature from existing clinical MRIs and identified that larger fibrosis volume was associated with worse swallowing function. The reliable capture of fibrosis volume offers a pragmatic method for early detection of fibrosis and concomitant dysphagia.
RESUMO
Introduction: Thickened liquids are commonly recommended to reduce the risk of penetration-aspiration. However, questions persist regarding the impact of bolus consistency on swallowing safety. The common practice of summarizing Penetration-Aspiration Scale (PAS) scores based on worst scores is a bias in prior analyses. The aim of this study was to examine the impact of liquid consistency on PAS scores using a Bayesian multilevel ordinal regression model approach, considering all scores across repeated bolus trials. A second aim was to determine whether PAS scores differed across thickener type within consistency. Methods: We analyzed two prior datasets (D1; D2). D1 involved 678 adults with suspected dysphagia (289 female; mean age 69 years, range 20-100). D2 involved 177 adults (94 female; mean age 54 years, range 21-85), of whom 106 were nominally healthy and 71 had suspected dysphagia. All participants underwent videofluoroscopy involving ≥3 boluses of 20% w/v thin liquid barium and of xanthan-gum thickened barium in mildly, moderately and extremely thick consistencies. D2 participants also swallowed trials of slightly thick liquid barium, and starch-thickened stimuli for each thickened consistency. Duplicate blinded rating yielded PAS scores per bolus, with discrepancies resolved by consensus. PAS ratings for a total of 8,185 and 3,407 boluses were available from D1 and D2, respectively. Bayesian models examined PAS patterns across consistencies. We defined meaningful differences as non-overlapping 95% credible intervals (CIs). Results: Across D1 and D2, penetration occurred on 10.87% of trials compared to sensate (0.68%) and silent aspiration (1.54%), with higher rates of penetration (13.47%) and aspiration (3.07%) on thin liquids. For D1, the probability of a PAS score > 2 was higher for thin liquids with weighted PAS scores of 1.57 (CI: 1.48, 1.66) versus mildly (1.26; CI: 1.2, 1.33), moderately (1.1; CI: 1.07, 1.13), and extremely thick liquids (1.04; CI: 1.02, 1.08). D2 results were similar. Weighted PAS scores did not meaningfully differ between thin and slightly thick liquids, or between starch and xanthan gum thickened liquids. Discussion: These results confirm that the probability of penetration-aspiration is greatest on thin liquids compared to thick liquids, with significant reductions in PAS severity emerging with mildly thick liquids.
RESUMO
Open Partial Horizontal Laryngectomy (OPHL) Type IIa surgery is a conservative surgical technique used in the treatment of laryngeal carcinomas. In this pilot study, we aimed to characterize swallowing function and physiology in a series of patients after OPHL Type IIa surgery through comparison to healthy reference values for quantitative measures for videofluoroscopy. We performed retrospective quantitative analysis of videofluoroscopy recordings of thin liquid swallows for a preliminary sample of 10 male patients. Each videofluoroscopy clip was rated in triplicate by trained blinded raters according to the ASPEKT Method (Analysis of Swallowing Physiology: Events, Kinematics and Timing). This preliminary sample of patients with previous OPHL surgery showed functional airway protection, with only 2 patients showing incomplete laryngeal vestibule closure (LVC) and associated airway invasion. However, the majority of patients (90%) showed prolonged latencies to LVC and upper esophageal sphincter (UES) opening. Prolonged durations of LVC and UES opening were also noted, but these were in the direction of compensation rather than impairment. Reduced pharyngeal area at rest was seen in 70% of the sample, and all patients showed poor pharyngeal constriction. Post-swallow residue was a prominent finding in ≥ 75% of these patients. In particular, reduced or absent constriction of the hypopharynx in the region of the pyriform sinuses was noted as a characteristic of swallowing in this sample. The data from these patients suggest that despite functional airway protection, severe swallowing dysfunction involving poor pharyngeal constriction and bolus clearance may be likely after OPHL surgery.
Assuntos
Transtornos de Deglutição , Laringectomia , Gravação em Vídeo , Humanos , Masculino , Laringectomia/efeitos adversos , Laringectomia/métodos , Transtornos de Deglutição/fisiopatologia , Transtornos de Deglutição/etiologia , Fluoroscopia/métodos , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Projetos Piloto , Neoplasias Laríngeas/cirurgia , Neoplasias Laríngeas/fisiopatologia , Deglutição/fisiologia , Faringe/fisiopatologia , Faringe/diagnóstico por imagemRESUMO
PURPOSE: To characterize pharyngeal function in people with Parkinson's Disease using both high resolution impedance manometry (HRIM) and videofluoroscopy (VFSS) and to explore correlations between VFSS and HRIM metrics. METHODS: All participants received both VFSS and HRIM within 24 h-time window. A standard VFSS protocol (IDDSI 0: 1 mL, 3 mL, 20 mL, and 100 mL) was performed. A solid-state unidirectional catheter (36 pressure sensors) was used to acquire manometric data for triplicate swallows (IDDSI 0: 5 mL, 10 mL, 20 mL), quantitative swallow analysis was completed through Swallowtail™ and SwallowGateway™. Parameters were compared to published norms and statistical tests explored correlational associations (p < 0.05). RESULTS: Twenty-one participants (76% male; mean age 70 years, SD7.16) with mild-moderate severity PD were recruited with 73% reporting Eating Assessment Tool (EAT-10) scores ≥3 indicating swallow impairment. Compared to normal metrics, one third of participants had abnormally elevated hypopharyngeal contractile integral (HPCI), hypopharyngeal peak pressure, upper esophageal sphincter (UES) integrated relaxation pressure (UES IRP), and reduced UES maximum admittance. Five participants showed compromised swallow safety (Penetration-Aspiration Scale score ≥6). One third of participants had abnormal VFSS values for pharyngoesophageal segment (PES) opening duration, maximum PES opening distance, and maximum hyoid displacement measures. Some HRIM metrics had a strong correlation with pharyngeal VFSS measures (r > 0.60, p < 0.05). CONCLUSION: This study identifies early manometric signs of pharyngeal dysfunction in people with PD. The congruence of the VFSS and HRIM measures confirms the hypothesis of insidious early decline in swallow function in PD despite maintenance of airway safety (i.e., low aspiration rates).
Assuntos
Transtornos de Deglutição , Doença de Parkinson , Humanos , Masculino , Idoso , Feminino , Transtornos de Deglutição/diagnóstico por imagem , Deglutição , Impedância Elétrica , Doença de Parkinson/diagnóstico , Esfíncter Esofágico Superior , Manometria/métodos , Faringe/diagnóstico por imagemRESUMO
PURPOSE: The tracheoesophageal puncture for the voice prosthesis (VP) placement is the recognized gold standard in post-laryngectomy voice rehabilitation. Despite the development of specific intraoperative techniques, a subset of patients will suffer from poor functional outcomes due to pharyngoesophageal spasms (PES). This paper evaluates the functional outcomes after transcutaneous botulinum toxin type A (BTX-A) infiltration for PES with a videofluoroscopy-guided technique. METHODS: Since 2022, eight consecutive patients with VP and affected by PES were treated with BTX-A injection by a standard videofluoroscopic guided technique at the European Institute of Oncology, IRCCS (IEO) in Milan. A lidocaine test was performed pre-operatively to evaluate the potential effect of chemical neurectomy. All patients with positive lidocaine tests were injected with 50 IU of BTX-A (Allergan, Irvine, CA) according to the sites marked during the videofluoroscopy. Reported symptoms (VHI, SECEL), perceptual (INFVo), aerodynamic (MPT) and manometric parameters were collected before and after treatment. RESULTS: In all cases, BTX-A was performed as an outpatient procedure without complications. For seven patients, only one BTX-A injection was needed, while one patient required a re-injection. Subjective and perceptive improvement after BTX-A was significant for VHI, SECEL and INFVo. MPT showed significant improvement after a chemical neurectomy. After a mean follow-up of 6 months, all patients maintained a good TES quality. CONCLUSION: The videofluoroscopic guided BTX-A injection of the pharyngoesophageal tract showed to be a feasible and reproducible technique in all cases. The pharyngoesophageal videofluoroscopy allows defining of patients' anatomical landmarks that help the surgeon to perform a homogeneous injection, empowered by post-injection massage.
Assuntos
Toxinas Botulínicas Tipo A , Humanos , Fala , Laringectomia/efeitos adversos , Voz Esofágica , Espasmo/etiologia , Lidocaína , Resultado do TratamentoRESUMO
Dysphagia, a potentially fatal symptom of Parkinson's disease, is characterized by frequent silent aspiration, a risk factor for aspiration pneumonia. The transdermal dopamine agonist rotigotine alleviates dysphagia in patients with Parkinson's disease and is more effective than oral levodopa, suggesting the importance of continuous dopaminergic stimulation during swallowing. Rasagiline is a monoamine oxidase B (MAOB) inhibitor that facilitates continuous dopaminergic stimulation. We hypothesized that MAOB inhibition by rasagiline would be effective in improving swallowing function in patients with early- and mid-to late-stage Parkinson's disease. To this end, we performed an analytical observational study to determine the effects of rasagiline (1 mg/day) on swallowing function using videofluoroscopic swallowing study. This open-label, evaluator-blinded study enrolled 32 patients with Parkinson's disease, among whom 19 were drug-naïve and 13 were receiving add-on therapy. Our results showed that rasagiline significantly improved all swallowing measures during the oral and pharyngeal phases, including oral transit time and pharyngeal transit time, in all enrolled patients. Similar results were found in drug-naïve and mid-to late-stage patients, with no intergroup differences. In conclusion, drugs capable of continuous dopaminergic stimulation may effectively improve swallowing function in patients with Parkinson's disease, with similar effects in early- and mid-to late-stage Parkinson's disease. This study has been the first to show that rasagiline significantly improves swallowing function in mid-to late-stage patients receiving add-on therapy.
RESUMO
BACKGROUND: Videofluoroscopy (VFS) is the gold standard in evaluating dysphagia. Water swallow tests (WST) and the Eating Assessment Tool (EAT-10) are commonly used in dysphagia screening. We aimed to determine the feasibility of WST and EAT-10 as screening tools for referral to VFS. METHODS: Patients (n = 150, median age: 70.0 years, range: 19-92 years, 58.7% female) referred to VFS completed the WST and EAT-10 before the examination. In the WST, we evaluated both the qualitative parameters (coughing, possible change in voice) and quantitative parameters (average drinking bolus size, swallowing speed). Correlations of EAT-10 total scores and WST parameters to the VFS findings were analyzed both individually and combined. RESULTS: In the WST, the most specific (89.7%) predictor of normal VFS findings was the absence of coughing, and the most sensitive (79.1%) parameter to predict abnormal findings was a bolus size of ≤20 mL. Using a combination of coughing and a bolus size ≤20 mL (simplified WST), the sensitivity of predicting abnormal findings increased to 83.5%. The most sensitive (84.6%) predictor of penetration/aspiration was failing any parameter in the WST. Lack of coughing indicated an absence of penetration/aspiration with an 82.5% specificity. Swallowing speed or combining the EAT-10 results with the WST results did not enhance the sensitivity or specificity of the WST for predicting the VFS results. CONCLUSIONS: Coughing and average drinking bolus size are the most important parameters in WST when screening for referral to VFS, whereas the swallowing speed does not seem to be useful. The WST is superior to EAT-10 in predicting VFS findings. LEVEL OF EVIDENCE: 4 Laryngoscope, 134:1349-1355, 2024.
Assuntos
Transtornos de Deglutição , Humanos , Feminino , Idoso , Masculino , Transtornos de Deglutição/diagnóstico por imagem , Água , Deglutição , Aspiração Respiratória/diagnóstico , Tosse , Encaminhamento e ConsultaRESUMO
BACKGROUND: Little is known about pharyngeal shortening (PShort) during swallowing. This observational study measured PShort during swallowing in healthy adults and compared it to patients with swallowing impairments of different aetiologies. METHODS: 275 healthy volunteers (19-99 years) and 75 dysphagic patients (25 with head and neck cancer, 25 with Parkinson's, 25 with stroke) underwent videofluoroscopy. A novel quantitative measure of PShort for 1, 3, and 20 mL thin liquid barium and 3 mL paste boli was determined and compared across age, sex, bolus type and patient cohort. RESULTS: PShort ranged from 1.05 to 4.41 cm across bolus types with larger displacements for 20 mL (M: 2.52 cm) and paste (M: 2.43 cm) compared with 1 mL (M: 2.36 cm) and 3 mL (M: 2.41 cm). PShort correlated with sex, height, and cohort but not age. Inter-rater reliability for three raters was substantial (intraclass correlation >0.80). CONCLUSIONS: This novel fluoroscopic measure of PShort is reliable and demonstrates quantitative changes in vertical pharyngeal displacement in healthy and swallow-impaired adults related to sex, size, and bolus type. LEVEL OF EVIDENCE: 3 Laryngoscope, 134:2121-2126, 2024.
Assuntos
Transtornos de Deglutição , Adulto , Humanos , Reprodutibilidade dos Testes , Transtornos de Deglutição/diagnóstico por imagem , Transtornos de Deglutição/etiologia , Deglutição , Faringe/diagnóstico por imagem , FluoroscopiaRESUMO
INTRODUCTION: To validate the Group for Learning Useful and Performant Swallowing (GLUPS), a clinical tool dedicated to videofluoroscopy swallowing study (VFSS). METHODS: Forty-five individuals were recruited from January 2022 to March 2023 from the Department of Otolaryngology Head and Neck Surgery of University Hospital Saint-Pierre (Brussels, Belgium). Subjects underwent VFSS, which was rated with GLUPS tool by two blinded otolaryngologists and one speech-therapist. VFSS were rated twice with GLUPS within a 7-day period to assess test-retest reliability. RESULTS: Twenty-four patients and twenty-one controls completed the evaluations. The internal consistency (α = 0.745) and the test-retest reliability (rs = 0.941; p = 0.001) were adequate. GLUPS reported a high external validity regarding the significant correlation with the Penetration-Aspiration Scale (rs = 0.551; p = 0.001). Internal validity was adequate, because GLUPS score was significant higher in patients compared to controls (6.21 ± 4.42 versus 2.09 ± 2.00; p = 0.001). Interrater reliability did not report significant differences in the GLUPS sub- and total score among the independent judges. The mean GLUPS score of individuals without any evidence of VFSS abnormalities was 2.09/23 (95% CI 1.23-2.95), which supported that a GLUPS score ≥ 3.0 is suggestive of pathological VFSS. CONCLUSIONS: GLUPS is a clinical instrument documenting the abnormal findings of oral and pharyngeal phases at the VFSS. GLUPS demonstrated high reliability and excellent criterion-based validity. GLUPS may be used in clinical practice for the swallowing evaluation at the VFSS.
Assuntos
Transtornos de Deglutição , Deglutição , Humanos , Transtornos de Deglutição/diagnóstico por imagem , Transtornos de Deglutição/etiologia , Reprodutibilidade dos Testes , Fluoroscopia , Aspiração Respiratória/etiologia , Aspiração Respiratória/complicaçõesRESUMO
Even without diseases that cause dysphagia, physiological swallowing function declines with age, increasing the risk of aspiration. This study analyzed age-related changes in laryngeal movement in older adults. The study population consisted of 10 volunteers in their 80s and six in their 20s. A videofluoroscopic study of 3 and 10 mL barium swallows was performed laterally using a digital fluorographic. The recorded images were retrieved to a personal computer and analyzed frame-by-frame using video analysis software. The movement of the larynx during swallowing, barium's pharyngeal transit time (PTT), and laryngeal elevation delay time (LEDT) were analyzed. Results were compared between the 20s and 80s age groups using statistical analyses. The PTT was shorter in the 20s than in the 80s age group. The PTT was significantly longer in the 80s group than in the 20s for both 3 and 10 mL barium swallows. LEDT in the 80s was statistically significantly longer than that in the 20s for the 10 ml barium. No statistically significant differences were found; however, there was a tendency for the 80s group to have more types of laryngeal movement velocity peaks. In this study, LEDT was prolonged in the 80s with 10 ml barium swallowing than in the 20s. Two peak patterns of laryngeal elevation during swallowing were observed. The velocity peaks showed a two-peak pattern when the patients were in their 80s and when the barium volume was tested at 10 mL. Our results suggest that aging's effect on swallowing relates to laryngeal elevation.