1.
Hellenic J Cardiol ; 2024 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-39038608

RESUMO

BACKGROUND: Bicuspid aortic valve (BAV) is prone to promote the occurrence of left ventricular remodeling (LVR) which is associated with adverse clinical outcomes. Although the association between angiogenic activity and LVR has been established, pro-angiogenic cytokine features and potential biomarker candidates for LVR in BAV patients remain to be clarified. METHODS: From November 2018 to May 2019, BAV patients diagnosed by transthoracic echocardiography at our institution were included. LVR was diagnosed based on echocardiographic calculations of relative wall thickness (RWT) and left ventricular mass index (LVMI). A multiplex ELISA array was used to measure the plasma levels of 60 angiogenesis-related cytokines. RESULTS: Among 103 BAV patients, 71 were categorized into LVR group and 32 into normal LV geometry group. BAV patients with LVR demonstrated increased LVMI, elevated prevalence of moderate to severe aortic stenosis and aortic regurgitation, and decreased left ventricular ejection fraction (LVEF). Plasma level of Angiopoietin-1 was elevated in BAV patients with or without LVR compared to healthy controls (P = 0.001, P < 0.001, respectively) and was negatively correlated with RWT (r = -0.222, P = 0.027). Plasma level of Angiopoietin-2 was elevated in the LVR group (P = 0.001) compared to normal LV geometry group and was negatively correlated with LVEF (r = -0.330, P = 0.002). CONCLUSION: Decreased angiogenesis plays a crucial role in the occurrence and progression of LVR in BAV patients. Disturbance in the pro- and anti-angiogensis equilibrium in BAV patients with LVR may reflect the aggravation of endothelial injury and dysfunction.

2.
Artigo em Inglês | MEDLINE | ID: mdl-39038780

RESUMO

OBJECTIVE: Permanent pacemaker implantation (PPI) after AVR is associated with long-term mortality. However, data regarding PPI after aortic root replacement (ARR) is lacking. Herein we describe the incidence, risk factors, and long-term outcomes of PPI after ARR. METHODS: Consecutive patients undergoing ARR from 2005-2020 were selected after excluding those with endocarditis, Type A dissection, or preoperative PPI. Patients requiring PPI after ARR were identified, along with the indication and timing. Independent factors associated with PPI after ARR were identified and long-term survival was assessed. RESULTS: The incidence of PPI was 3.8% (n=85) among 2240 patients undergoing ARR. PPI was performed a median of 7 days (IQR 5-12) after ARR most commonly for complete heart block (73%). Bicuspid aortic valve (OR 1.89, p=0.02), female gender (OR 1.74, p=0.04), preoperative heart block (OR 2.70, p=0.02), and prior AVR (OR 2.18, p=0.01) were independently associated with PPI while preoperative aortic insufficiency (OR 0.52, p=0.01) and VSRR procedure compared to bio-Bentall (OR 0.40, p=0.01) were protective. Patients requiring PPI after ARR were not at increased risk of operative or long-term mortality compared to patients not requiring PPI (p=0.26), however those undergoing PPI suffered from significantly longer hospital length of stay (13 vs 7 days, p<0.001). CONCLUSIONS: The incidence of PPI after ARR remains low, particularly after VSRR. Preoperative conduction disturbance, prior AVR, and bicuspid AV are all associated with increased risk of PPI. While PPI is associated with longer length of stay, it is not associated with early or late mortality.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38965018

RESUMO

BACKGROUND: Left ventricular (LV) structural and functional changes have been reported in patients with aortic stenosis (AS) who have undergone transcatheter aortic valve implantation (TAVI); however, the relationship between change in LV structure and systolic function and tissue characteristics assessed via cardiovascular magnetic resonance imaging (CMRI) post-TAVI has been not fully elucidated. This study aimed to investigate this relationship in patients with severe AS who underwent TAVI and CMRI. METHODS: In this retrospective study, 65 patients who underwent TAVI and CMRI at the 6-month follow-up were analyzed. The relationship between percent changes in LV end-diastolic volume (LVEDV), LV end-systolic volume (LVESV), LV ejection fraction (LVEF), and LV mass (LVM) (⊿LVEDV, ⊿LVESV, ⊿LVEF, and ⊿LVM) and those in the native T1 value (⊿native T1) was analyzed using a correlation analysis. Moreover, extracellular volume fraction (ECV) value changes were analyzed. RESULTS: The ⊿native T1 significantly decreased from 1292.8 (1269.9-1318.4) ms at pre-TAVI to 1282.3 (1262.6-1310.2) ms at the 6-month follow-up (P = 0.022). A significant positive correlation between ⊿LVEDV, ⊿LVESV, and ⊿LVM and ⊿native T1 (r = 0.351, P = 0.004; r = 0.339, P = 0.006; r = 0.261, P = 0.035, respectively) and a tendency toward a negative correlation between ⊿LVEF and ⊿native T1 (r = -0.237, P = 0.058) were observed. The ECV value increased significantly from 26.7 % (25.3-28.3) to 28.2 % (25.7-30.5) (P = 0.002). CONCLUSIONS: The decrease in native T1 might be associated with LV reverse remodeling. Evaluating structural and functional changes using CMRI may be useful for patient management.

5.
Front Cardiovasc Med ; 11: 1370736, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38966752

RESUMO

Rothia dentocariosa is a conditionally pathogenic bacterium that may cause infective endocarditis (IE) in selected patients and give rise to a variety of clinical complications, albeit it is not a common IE pathogen. We present the case of a patient diagnosed with Rothia dentocariosa-associated IE secondary to influenza B and thrombocytopenic purpura. The blood culture revealed Rochebacterium caries, cardiac ultrasound detected vegetation, while brain and spleen abscesses manifested and progressively deteriorated. Despite a suboptimal response to anti-infective therapy, the patient ultimately underwent aortic valve replacement. Discharge from the hospital was achieved upon control of the brain abscess and spleen abscess.

6.
Eur J Heart Fail ; 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39014551

RESUMO

AIMS: Lung ultrasound (LUS) is a sensitive tool to assess pulmonary congestion (PC). Few data are available on LUS-PC evaluation in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). The aim of this study was to assess the prevalence and prognostic impact of LUS-PC in patients with severe AS before and after TAVI. METHODS AND RESULTS: We designed a single-centre prospective study in patients referred for TAVI for severe AS (ClinicalTrials.gov identification number: NCT05024942). All patients underwent echocardiography and LUS (according to a simplified 8-zone scanning protocol) the day before and within 72 h after the procedure. The primary endpoint was the composite of all-cause mortality, hospitalization for heart failure and urgent medical visits for worsening dyspnoea at 12-month follow-up. A total of 127 patients were enrolled (mean age 81.1 ± 5.8 years; 54.3% female). Pre-TAVI LUS-PC was documented in 65 patients (51%). After TAVI, the prevalence of LUS-PC significantly decreased as compared to pre-TAVI evaluation, being documented in only 28 patients (22% vs. 51%, p < 0.001) with a median B-lines score of 4 (interquartile range [IQR] 0-11) versus 11 (IQR 6-19) pre-TAVI (p < 0.001). During a median follow-up of 12 (12-17) months, 25 patients (19.6%) met the composite endpoint. On multivariable Cox regression analysis, pre-TAVI LUS-PC was independently associated with cardiovascular events (hazard ratio 2.764, 95% confidence interval 1.114-6.857; p = 0.028). CONCLUSIONS: Lung ultrasonography reveals a high prevalence of PC in patients with severe AS undergoing TAVI, which is significantly reduced by the procedure. Pre-TAVI PC, measured by LUS, is an independent predictor of 1-year clinical outcome.

7.
JTCVS Open ; 19: 9-30, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39015444

RESUMO

Background: There is no consensus regarding the strategies for repairing acute type A aortic dissection (ATAAD) in patients with bicuspid aortic valve (BAV). This meta-analysis aimed to compare the treatment strategies and outcomes of ATAAD repair between patients with BAV and those with tricuspid aortic valve (TAV). Methods: A systematic review of databases were performed from inception through March 2023. The primary outcome of interest was all-cause mortality, with a minimum follow-up of 1 year. The secondary outcomes of interest included ratios of performed procedures and rate of distal aortic reoperation. Data were extracted, and pooled analysis was performed using a random-effects model. Results: Eight observational studies including a total of 3701 patients (BAV, n = 349; TAV, n = 3352) were selected for a meta-analysis. Concerning proximal aortic procedures, BAV patients exhibited a higher incidence of necessary root replacement (odds ratio [OR], 6.53; 95% confidence interval [CI], 3.84 to 11.09; P < .01). Regarding distal aortic procedures, extended arch replacement was performed less frequently in BAV patients (OR, 0.69; 95% CI, 0.49 to 0.99; P = .04), whereas hemiarch procedure rates were comparable in the 2 groups. All-cause mortality was lower in the BAV group (hazard ratio, 0.68; 95% CI, 0.50 to 0.92; P = .01). Distal aortic reoperation rates were comparable in the 2 groups. Conclusions: This study highlights distinct procedural patterns in ATAAD patients with BAV and TAV. Despite differing baseline characteristics, BAV patients exhibited superior survival compared to TAV patients, with comparable distal aortic reoperation rates. These findings may be useful for decision making regarding limited versus extended aortic arch repair.

8.
JTCVS Open ; 19: 47-60, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39015468

RESUMO

Objective: Bicuspid aortic valve (AV) patients with aortic regurgitation (AR) differ from tricuspid AV patients given younger age, greater left ventricle (LV) compliance, and more prevalent aortic stenosis (AS). Bicuspid AV-specific data to guide timing of AV replacement or repair are lacking. Methods: Adults with bicuspid AV and moderate or greater AR who underwent aortic valve replacement or repair at our center were studied. The presurgical echocardiogram, and echocardiograms within 3 years postoperatively were evaluated for LV geometry/function, and AV function. Semiquantitative AS/AR assessment was performed in all patients with adequate imaging. Results: One hundred thirty-five patients (85% men, aged 44.5 ± 15.9 years) were studied (63% pure AR, 37% mixed AS/AR). Following aortic valve replacement or repair, change in LV end-diastolic dimension and change in LV end-diastolic volume were associated with preoperative LV end-diastolic dimension (ß = 0.62 Δcm/cm; 95% CI, 0.43-0.73 Δcm/cm; P < .001), and LV end-diastolic volume (ß = 0.6 ΔmL/mL; 95% CI, 0.4-0.7 ΔmL/mL; P < .001), respectively, each independent of AR/AS severity (P = not significant). Baseline LV size predicted postoperative normalization (LV end-diastolic dimension: odds ratio, 3.75/cm; 95% CI, 1.61-8.75/cm, LV end-diastolic volume: odds ratio, 1.01/mL; 95% CI, 1.004-1.019/mL, both P values < .01) whereas AR/AS severity did not (P = not significant). Indexed LV end diastolic volume outperformed LV end-diastolic dimension in predicting postoperative LV normalization (area under the curve = 0.74 vs 0.61) with optimal diagnostic cutoffs of 99 mL/m2 and 6.1 cm, respectively. Postoperative indexed LV end diastolic volume dilatation was associated with increased risk of death, transplant/ventricular assist device, ventricular arrhythmia, and reoperation (hazard ratio, 6.1; 95% CI, 1.7-21.5; P < .01). Conclusions: Remodeling extent following surgery in patients with bicuspid AV and AR relates to preoperative LV size independent of valve disease phenotype or severity. Many patients with LV end-diastolic dimension below current surgical thresholds did not normalize LV size. LV volumetric assessment offered superior diagnostic performance for predicting residual LV dilatation, and postoperative indexed LV end diastolic volume dilatation was associated with adverse prognosis.

9.
JTCVS Open ; 19: 68-90, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39015469

RESUMO

Objective: New echocardiographic definitions have been proposed for hemodynamic structural valve deterioration. We aimed to study their consistency in classifying structural valve deterioration after surgical aortic valve replacement. Methods: Data were used of patients undergoing surgical aortic valve replacement in a multicenter, prospective cohort study with a 5-year follow-up. All patients received the same stented bioprosthesis. Echocardiographic parameters were assessed by an independent core laboratory. Moderate or greater stenotic hemodynamic structural valve deterioration was defined according to Capodanno and colleagues, Dvir and colleagues, and the Valve Academic Research Consortium 3; regurgitation data were not considered in this analysis. Consistency was quantified on the basis of structural valve deterioration classification at subsequent time points. Results: A total of 1118 patients received implants. Patients' mean age was 70 years, and 75% were male. Hemodynamic structural valve deterioration at any visit was present in 51 patients (4.6%), 32 patients (2.9%), and 34 patients (3.0%) according to Capodanno, Dvir, and Valve Academic Research Consortium 3. A total of 1064 patients (95%) were never labeled with structural valve deterioration by any definition. After the first classification with structural valve deterioration, 59%, 59%, and 65% had no subsequent structural valve deterioration classification according to Capodanno, Dvir, and Valve Academic Research Consortium 3, respectively. Conclusions: The current definitions of hemodynamic structural valve deterioration are strong negative predictors but inconsistent positive discriminators for the detection of stenotic hemodynamic structural valve deterioration. Although the diagnosis of structural valve deterioration may be categorical, echocardiographic indices lack this degree of precision in the first 5 years after surgical aortic valve replacement. The inconsistency of current structural valve deterioration definitions impedes the detection of true valve degeneration, which challenges the clinical usefulness of these definitions.

10.
Cureus ; 16(6): e62477, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39015863

RESUMO

Introduction Data regarding clinical outcomes after transcatheter aortic valve replacement (TAVR) vs surgical aortic valve replacement (SAVR) in patients with sarcoidosis is lacking. This study aims to clarify the clinical outcomes of TAVR vs SAVR in patients with sarcoidosis. Methods Data was collected from the National Inpatient Sample database from 2016-2019 using validated ICD-10-CM codes for sarcoidosis, TAVR, and SAVR. Patients were divided into two cohorts: those who underwent TAVR and those who underwent SAVR. Statistical analysis was performed using Pearson's chi-squared test to determine clinical outcomes of TAVR vs SAVR in patients with sarcoidosis. Results The prevalence of sarcoidosis was 0.23% among total study patients (n=142,420,378). After exclusions, the prevalence of TAVR was 650 (49%) and SAVR was 675 (51%) in patients with sarcoidosis. Patients who underwent TAVR were on average older (74 vs 65 years old, p=0.001), and more likely to be female (57 vs 40%, p<0.001) compared to patients who underwent SAVR. The TAVR cohort had higher rates of congestive heart failure (CHF) (77.7 vs 42.2%, p=0.001), chronic kidney disease (CKD) (42.3 vs 24.4% p=0.001), anemia (5.4 vs 2.2%, p=0.004), percutaneous coronary intervention (PCI) (1.5 vs 0%, p=0.004), and hypothyroidism (31.5 vs 16.3%, p=0.001) compared to the SAVR cohort. Inpatient mortality post-procedure was higher in the SAVR cohort compared to the TAVR cohort (15 vs 0, p=0.001). Regarding post-procedure complications, respiratory complications were more common in the SAVR cohort (4.4 vs 0%, p=0.001), while TAVR was associated with a higher incidence of permanent pacemaker (PPM) insertion (2.15 vs 0.8%, p=0.001). There was no statistical difference in the development of acute kidney injury (AKI) (0.8 vs 1.5%, p=0.33), AKI requiring hemodialysis (0 vs. 0.7%, p=0.08), or stroke (0.8 vs 0.7, p=1) post-procedure between the two cohorts. Conclusion This study found that in the sarcoidosis population, TAVR was associated with reduced mortality, shorter hospital length of stay, and lower hospitalization costs in comparison to SAVR.

11.
J Mech Behav Biomed Mater ; 157: 106650, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-39018917

RESUMO

The assessment of stent fatigue in Transcatheter Aortic Valve Replacement (TAVR) systems is critical for the design of next-generation devices, both in vitro and in vivo. The mechanical properties of the bioprosthetic heart valves (BHVs) have a significant impact on the fatigue life of the metallic stent and thus must be taken into consideration when evaluating new TAVR device designs. This study aims to investigate the relationship between BHV anisotropic behaviour and the asymmetric deflections of the stent frame observed during in vitro testing. An explicit dynamics finite element model of the nitinol stent with attached bioprosthetic valve leaflets was developed to evaluate the deflections of the TAVR device under haemodynamic loading. Our results demonstrate that pericardium behaviour plays a dominant role in determining stent frame deflection. The anisotropic behaviour of the leaflets, resulting from collagen fibre orientation, affects the extent of deflection encountered by each commissure of the frame. This leads to asymmetric variation in frame deflection that can influence the overall fatigue life of the nitinol stent. This study highlights the importance of considering both the flexible nature of the metallic stent as well as the leaflet anisotropic behaviour in the design and fatigue assessment of TAVR systems.

12.
J Am Coll Cardiol ; 84(4): 382-407, 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39019533

RESUMO

Transcatheter technologies triggered the recent revision of the guidelines that progressively widened the indications for the treatment of aortic stenosis. On the surgical realm, a technology avoiding the need for sutures to anchor the prosthesis to the aortic annulus has been developed with the aim to reduce the duration of cardiopulmonary bypass and simplify the process of valve implantation. In addition to a transcatheter aortic valve replacement (TAVR)-like stent that exerts a radial force, these so-called "rapid deployment valves" or "sutureless valves" for aortic valve replacement also have cuffs to improve sealing and reduce the risk of paravalvular leak. Despite promising, the actual advantage of sutureless valves over traditional surgical procedures (surgical aortic valve replacement) or TAVR is still debated. This review summarizes the current comparative evidence reporting outcomes of "sutureless valves" for aortic valve replacement to TAVR and surgical aortic valve replacement in the treatment of aortic valve stenosis.


Assuntos
Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Desenho de Prótese , Estenose da Valva Aórtica/cirurgia , Procedimentos Cirúrgicos sem Sutura/métodos , Valvopatia Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos
14.
J Am Heart Assoc ; : e035605, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39023065

RESUMO

BACKGROUND: Thresholds of aortic valve calcification (AVC) to define hemodynamically moderate aortic stenosis (AS) from mild are lacking. We aimed to establish a novel grading classification of AVC as quantified by computed tomography and determine its prognostic value. METHODS AND RESULTS: This study included 915 patients with at least mild AS (mean age 70±12 years, 30% women) from a multicenter prospective registry. All patients underwent Doppler-echocardiography and noncontrast computed tomography within 3 months. Primary end point was the occurrence of all-cause death. Receiver operating characteristic curves analyses were used to determine the sensitivity and specificity of sex-specific thresholds of AVC to identify hemodynamically moderate AS. Optimal thresholds (ie, with best sensitivity/specificity) of AVC to distinguish moderate (aortic valve area 1.0-1.5 cm2 and mean gradient 20-39 mm Hg) from mild AS (aortic valve area >1.5 cm2 and mean gradient <20 mm Hg) were AVC ≥360 arbitrary units in women and ≥1037 arbitrary units in men. Based on the guidelines' thresholds for severe AS and the new thresholds in our study for moderate AS, 312 (34%) patients had mild, 253 (28%) moderate, and 350 (38%) severe AVC. During a mean follow-up of 5.6±3.9 years, 183 (27%) deaths occurred. In Cox multivariable models, AVC remained associated with an increased risk of death (adjusted hazard ratio per grade increase, 1.94 [95% CI, 1.53-2.56]; P<0.001). CONCLUSIONS: A novel grading classification of anatomic AS severity based on sex-specific thresholds of AVC provides significant prognostic value for predicting mortality. These findings support the complementarity of computed tomography-calcium scoring to Doppler-echocardiography to corroborate AS severity and enhance risk stratification in patients with AS.

16.
Artigo em Inglês | MEDLINE | ID: mdl-39023453

RESUMO

BACKGROUND: Evidence is limited regarding the effectiveness of leadless pacemaker implantation for conduction disturbance following transcatheter aortic valve replacement (TAVR). OBJECTIVES: This study sought to examine the national trends in the use of leadless pacemaker implantation following TAVR and compare its performance with transvenous pacemakers. METHODS: Medicare fee-for-service beneficiaries aged ≥65 years who underwent leadless or transvenous pacemakers following TAVR between 2017 and 2020 were included. Outcomes included in-hospital overall complications as well as midterm (up to 2 years) all-cause death, heart failure hospitalization, infective endocarditis, and device-related complications. Propensity score overlap weighting analysis was used. RESULTS: A total of 10,338 patients (730 leadless vs 9,608 transvenous) were included. Between 2017 and 2020, there was a 3.5-fold increase in the proportion of leadless pacemakers implanted following TAVR. Leadless pacemaker recipients had more comorbidities, including atrial fibrillation and end-stage renal disease. After adjusting for potential confounders, patients with leadless pacemakers experienced a lower rate of in-hospital overall complications compared with patients who received transvenous pacemakers (7.2% vs 10.1%; P = 0.014). In the midterm, we found no significant differences in all-cause death (adjusted HR: 1.13; 95% CI: 0.96-1.32; P = 0.15), heart failure hospitalization (subdistribution HR: 0.89; 95% CI: 0.74-1.08; P = 0.24), or infective endocarditis (subdistribution HR: 0.98; 95% CI: 0.44-2.17; P = 0.95) between the 2 groups, but leadless pacemakers were associated with a lower risk of device-related complications (subdistribution HR: 0.37; 95% CI: 0.21-0.64; P < 0.001). CONCLUSIONS: Leadless pacemakers are increasingly being used for conduction disturbance following TAVR and were associated with a lower rate of in-hospital complications and midterm device-related complications compared to transvenous pacemakers without a difference in midterm mortality.

17.
Eur Radiol ; 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39023558

RESUMO

OBJECTIVES: To investigate the value of body composition indices derived from pre-procedural computed tomography (CT) in predicting 1-year mortality among patients who underwent transcatheter aortic valve replacement (TAVR). MATERIALS AND METHODS: We assessed consecutive patients who underwent TAVR between June 2016 and December 2021 at a single academic medical center. Skeletal muscle and subcutaneous fat area at the T4, T12, and L3 levels on pre-procedural CT were measured. The association between body composition and 1-year mortality was evaluated using Cox proportional hazard regression analysis. RESULTS: Finally, 408 patients were included (185 men and 223 women; mean age, 81.7 ± 5.1 years; range, 62-98 years). Post-procedural death occurred in 13.2% of patients. The muscle-height index and fat-height index at the L3 level were more strongly correlated with those at the T12 level (r = 0.765, p < 0.001 and r = 0.932, p < 0.001, respectively) than with those at the T4 level (r = 0.535, p < 0.001 and r = 0.895, p < 0.001, respectively). The cumulative 1-year mortality rate was highest for patients with both sarcopenia and adipopenia (26%), followed by those with adipopenia only (17%), those with sarcopenia only (12%), and those with neither sarcopenia nor adipopenia (8%, p = 0.002). Multivariable analysis revealed that body composition at the T12 level was an independent risk factor for 1-year mortality (hazard ratio: 4.09, 95% confidence interval: 2.01-8.35) in patients with both sarcopenia and adipopenia (p < 0.001). CONCLUSION: Sarcopenia or adipopenia assessed with CT at the thoracic level may be valuable for stratifying 1-year all-cause mortality in patients who undergo TAVR. CLINICAL RELEVANCE STATEMENT: Skeletal muscle and subcutaneous fat mass indices at the level of T12, measured on pre-procedural CT, have value for risk stratification of 1-year all-cause mortality in patients who undergo transcatheter aortic valve replacement. KEY POINTS: Sarcopenia and adipopenia are associated with the prognosis of patients undergoing transcatheter aortic valve replacement. Body composition at the T12 level was an independent risk factor for 1-year all-cause mortality. Sarcopenia or adipopenia assessed at T12 with pre-procedural CT is valuable for risk stratification.

18.
J Cardiothorac Surg ; 19(1): 452, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39014483

RESUMO

BACKGROUND: New prosthetic valves and surgical approaches that shorten operation time and improve the outcome of patients with aortic valve (AV) infective endocarditis (IE) and AV insufficiency (AVI) are crucial. The aim of this study was to evaluate the outcome of patients with AV IE or AVI treated with the EDWARDS INTUITY Rapid-Deployment AV prosthesis for this off-label indication. METHODS: This single-centre retrospective study analyzed data from patients who underwent AV replacement with the EDWARDS INTUITY Rapid-Deployment AV prosthesis for AV IE or regurgitation. (n = 8 for IE and n = 6 for AVI). RESULTS: Heart-lung machine times were significantly shorter in the AVI group (111.3 ± 20.7 min) compared to the IE group (171.9 ± 52.4 min) (p = 0.02). Aortic cross-clamp followed a similar trend (73.7 ± 9.9 min for AVI vs. 113.4 ± 35.6 min for IE) (p = 0.02). The length of ICU stay was also shorter in the AVI group (3.8 ± 2.6 days) compared to the IE group (16.9 ± 8.9 days) (p = 0.005). Postoperative echocardiography revealed no paravalvular leakage or significant valvular dysfunction in any patient. One patient died postoperatively from aspiration pneumonia. CONCLUSION: The INTUITY valve demonstrates as a safe option for complex AV IE and AVI surgery. Further prospective studies with larger patient cohorts are necessary to confirm these findings and explore the long-term benefits of this approach.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Masculino , Estudos Retrospectivos , Feminino , Pessoa de Meia-Idade , Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Endocardite/cirurgia , Endocardite/complicações , Valva Aórtica/cirurgia , Idoso , Resultado do Tratamento , Adulto
19.
Biomed Pharmacother ; 178: 117143, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39024838

RESUMO

Calcific aortic valve disease (CAVD) is prevalent in developed nations and has emerged as a pressing global public health concern due to population aging. The precise etiology of this disease remains uncertain, and recent research has primarily focused on examining the role of valvular interstitial cells (VICs) in the development of CAVD. The predominant treatment options currently available involve open surgery and minimally invasive interventional surgery, with no efficacious pharmacological treatment. This article seeks to provide a comprehensive understanding of valvular endothelial cells (VECs) from the aspects of valvular endothelium-derived nitric oxide (NO), valvular endothelial mechanotransduction, valvular endothelial injury, valvular endothelial-mesenchymal transition (EndMT), and valvular neovascularization, which have received less attention, and aims to establish their role and interaction with VICs in CAVD. The ultimate goal is to provide new perspectives for the investigation of non-invasive treatment options for this disease.

20.
Comput Methods Programs Biomed ; 255: 108314, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-39024970

RESUMO

BACKGROUND AND OBJECTIVE: Transcatheter aortic valve implantation (TAVI) has significantly transformed the management of aortic valve (AV) diseases, presenting a minimally invasive option compared to traditional surgical valve replacement. Computational simulations of TAVI become more popular and offer a detailed investigation by employing patient-specific models. On the other hand, employing accurate material modeling procedures and applying basic modeling steps are crucial to determining reliable numerical results. Therefore, this review aims to outline the basic modeling approaches for TAVI, focusing on material modeling and geometry extraction, as well as summarizing the important findings from recent computational studies to guide future research in the field. METHODS: This paper explains the basic steps and important points in setting up and running TAVI simulations. The material properties of the leaflets, valves, stents, and tissues utilized in TAVI simulations are provided, along with a comprehensive explanation of the geometric extraction methods employed. The differences between the finite element analysis, computational fluid dynamics, and fluid-structure interaction approaches are pointed out and the important aspects of TAVI modeling are described by elucidating the recent computational studies. RESULTS: The results of the recent findings on TAVI simulations are summarized to demonstrate its powerful potential. It is observed that the material properties of aortic tissues and components of implanted valves should be modeled realistically to determine accurate results. For patient-specific AV geometries, incorporating calcific deposits on the leaflets is essential for ensuring the accuracy of computational findings. The results of numerical TAVI simulations indicate the significance of the selection of optimal valves and precise deployment within the appropriate anatomical position. These factors collectively contribute to the effective functionality of the implanted valve. CONCLUSIONS: Recent studies in the literature have revealed the critical importance of patient-specific modeling, the selection of accurate material models, and bio-prosthetic valve diameters. Additionally, these studies emphasize the necessity of precise positioning of bio-prosthetic valves to achieve optimal performance in TAVI, characterized by an increased effective orifice area and minimal paravalvular leakage.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...