Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 263
Filtrar
1.
BMC Oral Health ; 24(1): 916, 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39118095

RESUMO

BACKGROUND: The posterior maxilla presents challenges for implant insertion because of the poor bone quality as well as the loss of vertical bone height. Indirect transcrestal sinus lift techniques are advised when a few millimeters of additional height are needed. This study aimed to evaluate the clinical and radiographic outcomes of antral membrane balloon technique versus Densah burs for transcrestal maxillary sinus lifting with simultaneous implant placement. MATERIALS AND METHODS: This randomized clinical trial was conducted on 22 patients received 32 dental implants for replacement of missed maxillary posterior teeth after crestal maxillary sinus lifting. The patients were randomly divided into two groups. Group 1, patients underwent crestal sinus floor elevation with simultaneous implant placement using antral membrane balloon technique. Group 2, patients underwent crestal sinus floor elevation with simultaneous implant placement using Densah burs. Patients were evaluated clinically and radiographically using cone beam computed tomography (CBCT) at regular time intervals immediately, 6 months and 12 months after surgery. All clinical and radiographic parameters were statistically analyzed. RESULTS: All dental implants were successful for 12 months of follow up. Regarding implant primary stability, there was a statistical significant difference between the study groups in favor of Densah group (P = 0.004), while there was no significant difference after 6 months (P = 0.07). Radiographically, balloon group showed a statistically significant immediate postoperative vertical bone height (P < 0.0001), and significant reduction in vertical bone height after 6 months (P < 0.0001). Densah group showed significant increase in bone density (P ≤ 0.05). CONCLUSION: Both techniques demonstrated successful clinical and radiographic outcomes for crestal sinus lift. The antral membrane balloon group demonstrated better immediate postoperative vertical bone gain, while Densah burs had higher implant primary stability and bone density. TRIAL REGISTRATION: This study was registered in Clinical-Trials.gov PRS ( https://register. CLINICALTRIALS: gov ) under identification number NCT05922592 on 28/06/2023.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Levantamento do Assoalho do Seio Maxilar , Humanos , Levantamento do Assoalho do Seio Maxilar/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Implantação Dentária Endóssea/métodos , Adulto , Resultado do Tratamento , Seio Maxilar/cirurgia , Seio Maxilar/diagnóstico por imagem , Implantes Dentários , Maxila/cirurgia , Maxila/diagnóstico por imagem , Seguimentos
2.
J Dent ; 149: 105317, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39181431

RESUMO

OBJECTIVES: The present parallel randomized clinical trial aimed to assess, after a 3-year follow-up period, whether the choice of surgical technique-either manual or guided-and of the operator - non-expert operator or skilled - can affect the stability of peri­implant marginal bone levels in implants placed 1 mm sub-crestal. MATERIALS AND METHODS: Patients received platform-switched implants (Anyridge, MegaGen Implant Co., Gyeongbuk, South Korea) featuring a 5-degree internal conical connection and supporting single screw-retained fixed crowns. The implants were randomly assigned to be placed through a digitally static guided surgery procedure (Test group - GS) or a freehand surgical technique (Control Group - FH). A non-expert operator (fewer than 20 implants placed in his professional activity) was selected to perform procedures for the GS Group, while a skilled operator (with over 1000 implants placed in his professional activity) was chosen for the FH Group. Marginal bone level (MBL) was measured at prosthesis installation (t0) and at 1 (t1), 2 (t2) and 3 years (t3) of follow-up. Changes in MBL from t0 to t3 were analyzed through periapical radiographs. Moreover, MBL changes at all time points were correlated to different supra-crestal soft tissue heights (STH): less than 3 and ≥ 3 mm, respectively. RESULTS: 60 implants in 18 patients were examined, with 30 implants allocated to the GS group and 30 to the FH group. The difference in MBL change between the two groups was 0.11 ± 0.22 mm, which was not statistically significant (p = 0.61). At the time of prosthetic loading, the mean MBL for implants with STH less than 3 mm was 0.33 mm higher than implants with STH ≥ 3 mm, though this difference was not statistically significant (P = 0.065). CONCLUSIONS: Digitally static guided implant placement, performed by a non-expert operator, does not limit marginal bone remodeling, when compared to a freehand procedure performed by an experienced operator. CLINICAL SIGNIFICANCE: After correct and careful planning, early marginal bone levels (MBL) around conical connection, platform-switched implants placed sub-crestally may be stable in time. Digital planning and surgery have the potential to assist non-expert clinicians in achieving implant placements with comparable outcomes to those performed by experts.


Assuntos
Perda do Osso Alveolar , Implantação Dentária Endóssea , Implantes Dentários para Um Único Dente , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Implantação Dentária Endóssea/métodos , Perda do Osso Alveolar/diagnóstico por imagem , Adulto , Cirurgia Assistida por Computador/métodos , Seguimentos , Coroas , Idoso , Prótese Dentária Fixada por Implante , Resultado do Tratamento , Competência Clínica
3.
Int J Implant Dent ; 10(1): 39, 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39136808

RESUMO

PURPOSE: The aim of this long-term cohort study in periodontally compromised patients with implants was to analyze the correlation between gingival phenotype and peri-implant crestal bone loss, and between clinical measures and gingival phenotype. METHODS: Implant-supported single crowns and bridges were used to rehabilitate 162 implants in 57 patients. Patients were examined over a 2 to 20-year period on a recall schedule of 3 to 6 months. In addition to recording clinical parameters, intraoral radiographs were taken at baseline (immediately after superstructure insertion) and at 1, 3, 5, 10, 15, and 20 years. Patients were differentiated into phenotype 1 with thin, scalloped gingiva and narrow attached gingiva (n = 19), phenotype 2 with thick, flat gingiva and wide attached gingiva (n = 23), or phenotyp 3 with thick, scalloped gingiva and narrow attached gingiva (n = 15). RESULTS: The mean peri-implant crestal bone loss during the first 12 months was 1.3 ± 0.7 mm. Patients with gingival phenotype 1 had a significantly greater rate of increased crestal bone loss at implants (p = 0.016). No significant differences were present in subsequent years. The prevalence of mucositis at all implants was 27.2%, and the prevalence of peri-implantitis 9.3%. Univariate analyses indicated a significantly higher peri-implantitis risk in patients with gingival phenotype 2 (p-OR = 0.001; p-OR = 0.020). The implants of patients with phenotype 2 had significantly greater probing depths (1st year p < 0.001; 3rd year p = 0.016; 10th year p = 0.027; 15th year p < 0.001). Patients with gingival phenotype 3 showed no significantly increased probing depths, signs of inflammation and crestal bone loss. CONCLUSIONS: Patients with a gingival phenotype 1 have greater crestal bone loss at implants during the first year of functional loading. Patients with gingival phenotype 2 had significantly greater probing depth at implants and risk of peri-implantitis.


Assuntos
Perda do Osso Alveolar , Gengiva , Fenótipo , Humanos , Perda do Osso Alveolar/diagnóstico por imagem , Perda do Osso Alveolar/patologia , Masculino , Feminino , Pessoa de Meia-Idade , Gengiva/patologia , Adulto , Estudos de Coortes , Idoso , Estudos Longitudinais , Prótese Dentária Fixada por Implante , Implantes Dentários para Um Único Dente/efeitos adversos
4.
J Clin Periodontol ; 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39043452

RESUMO

AIM: This study aimed to assess hard and soft tissue contour changes following micro crestal flap-alveolar ridge preservation (MCF-ARP) and natural healing (NH) in periodontally compromised molar extraction sites and to analyse the feasibility and need for bone augmentation during implant therapy. MATERIALS AND METHODS: Fifty-six patients with 70 sites were randomized into two groups at the site level (35 sites from 31 patients in the test group and 35 sites from 29 patients in the control group). Among whom, four patients contributed one tooth to the control group and one tooth to the test group. Hard tissue indicators were measured using cone beam computed tomography performed before tooth extraction and 6 months after surgery. Soft tissue contour changes were assessed using intraoral scanning performed before and immediately after surgery and also 2 weeks and 1, 3 and 6 months after surgery. RESULTS: Six months after surgery, the MCF-ARP group showed less resorption in buccal bone height (p = .032) and greater augmentation in central bone height (p = .001) and ridge width (p = .009). The mean, vertical and horizontal collapse of buccal soft tissue contour in the MCF-ARP group were 0.95 mm (p = .010), 0.61 mm (p = .019) and 0.56 mm (p = .013) less than that in the NH group, respectively. There were significantly (p = .007) fewer sites in the MCF-ARP group than in the NH group (0% vs. 26.7%) for staged bone augmentation and more sites that could be treated with simple implant procedure in the MCF-ARP group than in the NH group (71.9% vs. 56.6%). CONCLUSIONS: Compared with NH, MCF-ARP reduced bone resorption in periodontally compromised molar extraction sites and maintained the buccal soft tissue contour. MCF-ARP reduces the need for complex bone augmentation procedures in implant therapy. TRIAL REGISTRATION: Chinese Clinical Trial Register (ChiCTR) ChiCTR2200056335. Registered on 4 February 2022, Version 1.0.

5.
Artigo em Inglês | MEDLINE | ID: mdl-39032079

RESUMO

PURPOSE: To histometrically compare the osseointegration and crestal bone healing of a novel tapered, self-cutting tissue-level test implant with a standard tissue-level control implant in a submerged healing regimen. MATERIALS AND METHODS: In a mandibular minipig model, implants were inserted and evaluated histometrically after a healing period of 3, 6, and 12 weeks. The primary outcome was the evaluation of bone-to-implant contact (BIC) and secondary outcomes were primary stability as per insertion torque and first BIC (fBIC). Outcomes for the test and control implants were compared using Wilcoxon signed-rank tests and mixed linear regression models. RESULTS: Insertion torque values were significantly higher for the test (50.0 ± 26.4 Ncm) compared to the control implants (35.2 ± 19.7 Ncm, p = .0071). BIC values of test implants were non-inferior to those of control implants over the investigated study period. After 12 weeks, the corresponding values measured were 81.62 ± 11.12% and 90.41 ± 4.81% (p = .1763) for test and control implants, respectively. Similarly, no statistical difference was found for fBIC values, except for the 12 weeks outcome that showed statistically lower values for the test (-675.58 ± 590.88 µm) compared to control implants (-182.75 ± 197.40 µm, p = .0068). CONCLUSIONS: Novel self-cutting tissue-level implants demonstrated noninferior osseointegration and crestal bone height maintenance to the tissue-level implants. Histometric outcomes between both implants demonstrated test implants were statistically noninferior to control implants, despite substantial differences in the bone engagement mechanism and resulting differences in insertion torque and qualitative bone healing patterns.

6.
J Oral Implantol ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38961753

RESUMO

Graftless motor-driven crestal sinus elevation may be a preferable alternative to conventional methods due to the reduction of post-surgical complications and lower cost. This prospective cohort study evaluated the stability of implants installed using this technique. Twenty-nine Straumann BLT implants in 29 different patients were included in the sample. Average implant stability quotients (ISQ) were measured immediately after surgery (Mean 73.5 ± 9.2) and after a period of healing (Mean 77.1 ± 4.5) using resonance frequency analysis (RFA). There was a significant increase in implant stability after healing (p = .035). The healing duration did not significantly influence how implant stability increased (p =.373). The mean ISQ after healing was significantly higher than the clinically acceptable stability value of 65 ISQ (p <.001). Implant length and width were not significantly correlated with ISQ increase (p =.764 and p =.085, respectively). In addition, there were no significant differences in average ISQ values measured immediately post-surgery (at baseline) or after healing between implants with and without registered perforations during surgery (p =.118 and p =.366, respectively). The post-healing stability of four implants that did not achieve primary stability was not significantly less stable after the healing period than those that had achieved primary stability (p =.086). Moreover, the level of insertion torque significantly impacted implant stability immediately post-surgery (p < .001), but the ISQ values measured after healing were not significantly different based on the initial insertion torque values (p = .131). This study suggests that implants installed using graftless motor-driven crestal sinus elevation may achieve clinically acceptable stability as measured by RFA.

7.
J Pharm Bioallied Sci ; 16(Suppl 2): S1498-S1504, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38882717

RESUMO

The aim of this study is to determine the stress in short implants loaded with varying crown heights using a 3D finite element analysis. A total of three mandibular sectional bone blocks depicting the mandibular left first molar region were modeled. Each block carried Bicon implants of the same size and was designated B1, B2, and B3. The implant- crown ratio is 1:1.5, 1:2.5, and 1:3 respectively. The loading protocol included axial and oblique loads. The von Misses' equivalent stresses at the implant-bone interface were evaluated. Intergroup comparison was determined using one-way ANOVA analysis, and P values were calculated. Under an axial load of 600N, the models B1, B2, and B3 do not show any statistically significant P-values at the crestal module of the implant, abutment, and bone, whereas in crowns, the P-values were highly significant. Under an oblique load of 225 N at 0°, 45°, and 90°, model B3 showed the highest values in the crestal module, abutment, and crown. Based on the intergroup comparison and P value the study concluded that the variance in the crown height does not affect the bone and therefore microfracture of the bone and failure of osseointergration is not likely.

8.
BMC Oral Health ; 24(1): 691, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38877464

RESUMO

BACKGROUND: This study evaluated the clinical benefits of adding NanoBone® with split-crest technique and simultaneous implant placement covered with platelet-rich fibrin membrane in horizontally deficient maxillary ridges in terms of crestal and horizontal bone changes and patient morbidity. METHODS: Forty patients indicated for maxillary ridge splitting and simultaneous implant placement were assigned randomly to the study groups: control group (Platelet Rich Fibrin membrane) and test group (Platelet Rich Fibrin membrane + Nanobone®). The Cone Beam Computed Tomography Fusion technique was utilized to assess crestal and horizontal bone changes after five months of the surgical procedure. Patient morbidity was recorded for one week post-surgical. RESULTS: Five months post-surgical, buccal crestal bone resorption was 1.26 ± 0.58 mm for the control group and 1.14 ± 0.63 mm for the test group. Lingual crestal bone resorption was 1.40 ± 0.66 mm for the control group and 1.47 ± 0.68 mm for the test group. Horizontal bone width gain was 1.46 ± 0.44 mm for the control group and 1.29 ± 0.73 mm for the test group. There was no significant statistical difference between study groups regarding crestal and horizontal bone changes and patient morbidity. CONCLUSIONS: The tomographic assessment of NanoBone® addition in this study resulted in no statistically significant difference between study groups regarding crestal and horizontal bone changes and patient morbidity. More randomized controlled clinical trials on gap fill comparing different bone grafting materials versus no grafting should be conducted. GOV REGISTRATION NUMBER: NCT02836678, 13th January 2017.


Assuntos
Perda do Osso Alveolar , Tomografia Computadorizada de Feixe Cônico , Maxila , Fibrina Rica em Plaquetas , Humanos , Masculino , Feminino , Maxila/diagnóstico por imagem , Maxila/cirurgia , Pessoa de Meia-Idade , Perda do Osso Alveolar/diagnóstico por imagem , Implantes Dentários , Adulto , Aumento do Rebordo Alveolar/métodos , Implantação Dentária Endóssea/métodos , Idoso , Minerais/uso terapêutico , Seguimentos , Combinação de Medicamentos , Dióxido de Silício , Durapatita
9.
Int Dent J ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38866672

RESUMO

BACKGROUND: The aim was to assess the peri-implant clinicoradiographic status and prostaglandin E2 (PGE2) levels in peri-implant sulcular fluid (PISF) samples collected from individuals with cement-retained and crew-retained implants. METHODS: In this observational study, participants with cement-retained and screw-retained implants were enrolled. A questionnaire was utilized to gather demographic information and assess the educational background of the participants. Peri-implant modified plaque and bleeding indices, probing depth, and crestal bone loss were measured. Subsequently, PISF samples were collected, and corresponding volumes were recorded. Commercial kits employing enzyme-linked immunosorbent assay were employed to quantify PGE2 levels. The sample size was determined, and group comparisons were conducted using the Student t test and the Mann-Whitney U-test. Logistic regression models were constructed to evaluate the correlation between PGE2 levels and clinicoradiographic and demographics. The predefined level of significance was established at P < .05. RESULTS: Sixty-seven participants, consisting of 33 with cement-retained implants and 34 with screw-retained implants, were included in the study. The mean ages for individuals with cement and screw-retained implants were 54.2 ± 8.7 and 58.7 ± 7.4 years, respectively. The majority of participants had completed university-level education. Reportedly, 87.9% and 82.4% of individuals with cement and screw-retained implants, respectively brushed teeth twice daily. No significant differences were observed in clinicoradiographic parameters, PGE2 volume, and levels between cement-retained and screw-retained implants. There was no correlation between PGE2 levels and peri-implant clinicoradiographic parameters among individuals with either cement-retained or screw-retained implants. CONCLUSIONS: Cement-retained and screw-retained implants exhibit a consistent peri-implant clinicoradiographic status, accompanied by stable levels of PGE2 in PISF provided oral hygiene maintenance regimens are stringently followed.

10.
J Dent ; 146: 105094, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38788918

RESUMO

OBJECTIVE: The study answers the PECO question: "In adults with dental implants (P), do subjects suffering from type-2 diabetes or prediabetes (E) have worse peri-implant conditions (O) than subjects without type-2 diabetes and prediabetes (C)?". Prediabetes (5.7-6.4 % HbA1c), and the different qualities of glycemic control in type-2 diabetes; well-controlled (>8 % HbA1c), and poorly controlled (>8 % HbA1c) individuals; were classified according to the recommendations of the American Diabetes Association. DATA: Predefined search keys were used with search terms including: Dental implant, diabetes mellitus, glycemic control and HbA1c. SOURCES: An electronic search in the MEDLINE, Embase, and Cochrane libraries were conducted without any filters or language restrictions. Additionally, manual search of the reference lists were carried out to identify all relevant articles. STUDY SELECTION: Eligibility criteria were cohort, case-control and cross-sectional studies that answerd our PECO question with at least 1 year of follow-up. From a total of 2660 records, 35 articles (1761 individuals) were included in the analysis. Meta-analytic difference in means for crestal bone loss was 1.2 mm [95 % CI=0.4; 2.1] in patients with prediabetes, 1.8 mm [CI=1.0; 2.7] in poorly controlled patients, whereas 0.4 mm [CI=-0.3; 1.1] in well-controlled individuals. Meta-regression showed that 1 % increase in HbA1c increased crestal bone loss by 0.24 mm. CONCLUSIONS: Within the limitations of the study, patients with poorly controlled type-2 diabetes or prediabetes may have worse peri-implant conditions compared to patients without diabetes and well-controlled type-2 diabetes. Well-controlled type-2 diabetes is not a risk indicator for peri-implant diseases. CLINICAL SIGNIFICANCE: Clinicians should measure blood HbA1c levels when planning implant-supported restorations, thus patients with undiagnosed or poorly controlled type-2 diabetes can be identified, that allows for glycemic level adjustment prior to dental implant surgery, ensuring peri-implant health. PROTOCOL REGISTRATION NUMBER: (CRD42022375263).


Assuntos
Implantes Dentários , Diabetes Mellitus Tipo 2 , Hemoglobinas Glicadas , Estado Pré-Diabético , Humanos , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/sangue , Estado Pré-Diabético/sangue , Implantes Dentários/efeitos adversos , Hemoglobinas Glicadas/análise , Fatores de Risco , Peri-Implantite/etiologia , Controle Glicêmico
11.
Int J Oral Maxillofac Implants ; 0(0): 1-25, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38728147

RESUMO

Reducing crestal bone loss (CBL) around implants allows for soft tissue stability and long-term success. The aim of the present study was to evaluate the extent of CBL in implants placed with the implant shoulder at the equi-crestal level and 2 mm below the alveolar ridge at 2, 12, 36, and 60 months. A split-mouth randomized controlled clinical trial was conducted by selecting subjects with Kennedy Class IV partial edentulism of the lower jaw. Two implants were inserted, of equal length and diameter, one equi-crestal and the other sub-crestal, in the site corresponding to the lateral incisor. Intraoral periapical radiographs with Rinn centering devices were performed at the time of implant insertion (T0), at 2 (T1), 12 (T2), 36 (T3), and 60 months (T4). Descriptive statistics and the T-test were used, setting the significance to P⩽ 0.05. Twenty-five subjects were recruited, with a mean age of 65 years (SD 9.88, range 42-82). No subject dropped out. A total of 50 implants were inserted, 25 at crestal and 25 sub-crest level. At the 60-month follow-up, no implant or prosthetic failure was recorded. An average loss of -0.81 mm was recorded in the crestal implant group (n.25; SD: 0.40; max-min: -1.6 - -0.1) while in the implants positioned below the crest the average CBL was -0.87mm (n.25; SD: 0.41; max-min: -2 - -0.2); however, the higher CBL in the sub-crestal implant group was not statistically significant (P=0.65). Comparing the mean CBL values of the two groups at the various follow-ups, a greater crestal bone resorption was recorded in sub-crest implants between T0 and T1 (-0.25 vs -0.1) and between T1 and T2 (-0.39 vs -0.23), while in subsequent follow-ups a greater, statistically significant (P=0.01), crestal bone loss was recorded in ridge implants between T3 and T4 (-0.05 vs -0.18). Over time, therefore, the extent of CBL seems to be reduced in implants placed below the crest, with bone retention above the implant shoulder. Ultimately, although the position of the implant shoulder relative to the crestal ridge doesn't affect the CBL, sub-crestal placement is recommended in order to reduce the risk of exposure of the rough surface of the implant.

12.
Cureus ; 16(4): e58128, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38741844

RESUMO

The supracrestal tissue attachment (SCTA) is the new terminology for biologic width. SCTA is defined as the physiologic dimension of a solitary functional unit composed of junctional epithelium and connective tissue attachment. Its preservation is critical for the well-being of periodontal health. SCTA has been widely studied and scientific literature is indicative of its significance during the placement of restoration, including prosthetic crowns. This should be taken care of in cases of anterior teeth within the smile zone, where dental crowns are regularly placed subgingivally for aesthetic reasons. In addition, any violation of SCTA while restoring the dentition will present as gingival inflammation and pain, consequently, leading to failure of the clinical procedure.

13.
J Periodontal Res ; 2024 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-38764144

RESUMO

AIMS: To histologically compare osseointegration and crestal bone healing between newly introduced tapered, self-cutting bone-level test implants and tapered bone-level control implants in sites with fully healed sites. METHODS: Sixty-six implants (33 test, 33 control) were placed 1 mm subcrestally in a minipig model and underwent qualitative histologic and quantitative histometric analyses after 3, 6 and 12 weeks of submerged healing. The primary and secondary outcomes were the bone-to-implant contact (BIC) and first bone-to-implant contact (fBIC). Outcomes between the test and control implants were statistically compared. RESULTS: The BIC values of the test implants were comparable and non-inferior over the time points studied, except for the 12 weeks time point which showed statistically significantly higher BIC values of the test (88.07 ± 5.35%) compared to the control implants (80.88 ± 7.51%) (p = .010). Similarly comparable and non-inferior were the fBIC values, except for the 6-week outcome, which showed statistically higher values for the test (-546.5 ± 450.80 µm) compared to the control implants (-75.7 ± 100.59 µm). fBIC results for the test implants were qualitatively more stable and consistent between test time points. CONCLUSION: Novel self-cutting bone-level test implants demonstrated superior osseointegration and similar bone levels compared to conventional bone-level implants after a healing period of 12 weeks in healed ridges.

14.
Artigo em Inglês | MEDLINE | ID: mdl-38819108

RESUMO

OBJECTIVES: The aim of the present study was to compare a novel tapered, double-threaded self-tapping tissue-Level design implant (TLC) to a well-established parallel walled tissue-level (TL) implant in terms of primary and secondary stability over time. MATERIALS AND METHODS: Test TLC (n = 10/per timepoint) and control TL (n = 10/per timepoint) implants were placed in the mandible of minipigs and left for submerged healing for 3, 6, and 12 weeks. Maximum insertion torque and implant stability quotient (ISQ) were measured for each implant at placement. Osseointegration and cortical bone maintenance were histologically evaluated by measuring total bone-to-implant contact (BIC) and first bone-to-implant contact (fBIC). RESULTS: A significantly higher maximum insertion torque was measured for the test implant TLC compared to the control TL implant (57.83 ± 24.73 Ncm and 22.62 ± 23.16 Ncm, respectively; p < .001). The mean ISQ values were comparable between the two implant types (75.00 ± 6.70 for TL compared to 75.40 ± 3.20 for TLC, p = .988). BIC was comparable between both implant types at each of the evaluated time points. The fBIC was found to be significantly more coronal at 12 weeks for the TLC implant compared to the TL implant (0.31 ± 0.83 mm for TLC compared to -0.22 ± 0.85 for TL, p = .027). CONCLUSION: The novel tapered tissue level design implant showed improved primary stability and an overall improved crestal bone height maintenance compared to the parallel walled design at 12 weeks.

15.
J Pharm Bioallied Sci ; 16(Suppl 1): S724-S725, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595348

RESUMO

Objectives: To evaluate the loss of crestal bone height around dental implants placed in various tissue biotypes. Materials and Methods: 20 patients with single edentulous sites were allocated randomly, with 10 samples in each into Group I (implants were placed in thick tissue biotype) and Group II (implants were placed in thin tissue biotype). Baseline cone-beam computed tomography (CBCT) was performed after implant placement in both groups, and follow-up CBCT was taken at the time of cementation prior to occlusal loading to assess the crestal bone loss around the mesial and distal side of implants in both groups. Result: A significant loss of crestal bone at both the distal and mesial sides of the implants at the time of cementation was observed in both groups but Group II showed more crestal bone loss as compared to Group I. Conclusion: Mean crestal bone loss was more in Group II (thin tissue biotype) in comparison to Group I (thick tissue biotype). The thick biotype causes less crestal bone changes than the thin biotype, which evokes more loss of crestal bone during the period of peri-implant healing.

16.
J Pharm Bioallied Sci ; 16(Suppl 1): S279-S282, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595594

RESUMO

Objective: Simvastatin was used as an adjuvant medication in this clinico-radiographic investigation to assess the impact on crestal bone levels around immediate implantation. Materials and Methods: A randomized controlled trial with 50 patients who needed an implant placed right away was done. Simvastatin was used as an adjuvant in groups ((Group A), whereas group (Group B)) served as the control group for the participants. At baseline and during follow-up visits, clinical measures such as probing depth (PD) and bleeding on probing (BOP) were measured. At baseline and 12 weeks, radiographic measurements of crestal bone levels were taken. Results: At 12 weeks, Group A demonstrated a significantly lower PD and BOP than did Group B. Furthermore, at 12 weeks, Group A showed greater crestal bone preservation than did Group B. The results of the statistical analysis showed that the two groups were significantly different. Conclusion: The results of this study indicate that simvastatin use as an adjuvant medication after immediate implant insertion contributes to better clinical outcomes and greater crestal bone preservation. Simvastatin may be helpful in increasing bone regeneration, decreasing inflammation, and soft tissue healing. These findings demonstrate how simvastatin may be used as an additional therapy to enhance the effectiveness of rapid implant implantation operations.

17.
J Dent Sci ; 19(1): 338-344, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38303785

RESUMO

Background/purpose: Accuracy of using implant length on periapical radiographs as calibration reference for measurements has not been verified. This study aimed to verify the measurements of peri-implant crestal bone level (piCBL) on periapical radiographs taken by the paralleling technique and using the implant length for calibration; and to propose a customized crownlevel position (CLP) jig to improve the measurement accuracy of piCBL. Materials and methods: A typodont installed an implant and a screw-retained crown at maxillary central incisor was used. To simulate piCBL, a metal post was placed near the implant at the same height of implant platform. The CLP jig was designed and 3-dimensionally printed out to allow implant projected orthogonally on periapical film. Thirty periapical radiographs were taken using paralleling technique with and without the jig by three examiners. The implant axis and implant length on radiographs were acquired by image segmentation. The discrepancy of piCBL determination (ΔD) from these measurements were compared and further analyzed when using the implant length for calibration. Results: The piCBL measurement errors were smaller when the jig was used for all examiners (P < 0.001). The inter-rater differences were insignificant. After calibration, ΔD with and without jig were 0.09 (0.07-0.11) and 0.43 (0.38-0.49) mm, respectively. Conclusion: Conventional long-cone paralleling technique using true implant length for calibration demonstrated imprecise piCBL measurement on periapical radiographs. Transferring the implant axis to the CLP jig allowed orthogonal projection of radiography which provided reliable measurements of piCBL with an accuracy of less than 0.1 mm.

18.
J Oral Implantol ; 50(2): 95-102, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38353317

RESUMO

The aim of this study was to evaluate the radiographic and clinical outcomes of patients undergoing sinus membrane elevation via a minimally invasive crestal approach utilizing the dental implant. Twenty patients having 1 or more missing posterior teeth were included. The maxillary sinus membrane was elevated using dental implant via a crestal approach in areas with insufficient residual bone. CBCT scans were used to measure the amount of newly formed bone, implant length inside the sinus, bucco-palatal sinus width, and bone thickness. Surgical and postsurgical complications along with implant survival were also measured. The mean (±SD) values for the newly formed bone after 1 year were 2.4 (±1.87) mm, while values for implant length inside the sinus were 4 (±1.49) mm. The results showed that percentage of implant length inside the sinus and the palatal bone thickness were statistically significant positive predictors of the newly formed bone. Higher percentage of implant length inside the sinus and increased palatal bone thickness were associated with larger amounts of newly formed bone. A high patient satisfaction was reported along with a 100% implant survival. The utilization of the novel dental implant approach for crestal sinus elevation demonstrated predictable clinical and radiographic outcomes. This novel technique is simple to both patients and clinicians, rendering it a promising and cost-efficient procedure.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea , Implantes Dentários , Levantamento do Assoalho do Seio Maxilar , Humanos , Levantamento do Assoalho do Seio Maxilar/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Implantação Dentária Endóssea/métodos , Adulto , Seio Maxilar/cirurgia , Seio Maxilar/diagnóstico por imagem , Resultado do Tratamento , Satisfação do Paciente , Idoso , Procedimentos Cirúrgicos Minimamente Invasivos , Complicações Pós-Operatórias
19.
J Taibah Univ Med Sci ; 19(2): 313-320, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38283380

RESUMO

Objectives: Interleukin 1 (IL-1) and interleukin 6 (IL-6) gene polymorphisms have been suggested to be responsible for diminished bone mineral density (BMD) and high crestal bone loss (CBL) in some individuals. However, the effects of systemic BMD on variations in peri-implant CBL are unclear. Hence, this study was aimed at investigating the association of IL-1 and IL-6 gene polymorphisms with systemic BMD and CBL around dental implants. Methods: A total of 190 participants undergoing dental implantation in the mandibular posterior region were selected according to predetermined selection criteria and divided into a normal BMD group (NBD, 93 participants, T-score ≥ -1) and low BMD group (LBD, including both osteoporosis and osteopenia, 97 participants, T-score < -1 standard deviation) according to the BMD of the right femoral neck, measured with dual-energy X-ray absorptiometry. Dental implants were placed through the standard surgical protocol, and CBL was calculated after 6 months with cone beam computed tomography scans before second-stage surgery. Genotyping was performed on all participants for IL-1A-889 A/G, IL-1B-511G/A, IL-1B+3954, and IL-6-572 C/G gene polymorphisms. Results: The demographic and clinical characteristics of the participants in both groups were compared with t-test and chi-square test (χ2). The associations of NBD and LBD with the different genotypes and CBL was determined with odds ratios, and p < 0.05 was considered statistically significant. The frequency of IL-1B-511AA and IL-6-572 GG genotypes was significantly higher in LBD than in NBD (p < 0.05). In LBD, the IL-1B-511 AA (AA vs GA + GG; p ≤ 0.001) and IL-6-572 GG (GG vs CC + GC; p = 0.001) genotypes were significantly associated with higher peri-implant CBL. Conclusions: Individuals with the IL-1B-511 AA or IL-6-572 GG genotype had elevated risk of osteoporosis/osteopenia and were more susceptible to CBL around dental implants.

20.
Clin Implant Dent Relat Res ; 26(2): 333-342, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37984494

RESUMO

BACKGROUND: Lithium disilicate can be reliable when restoring implants in the esthetic zone. However, it has a high elastic modulus. This might increase the amount of forces transmitted to the crestal bone. AIM OF THE STUDY: To evaluate the crestal bone loss and peri-implant periodontal parameters of polymer infiltrated ceramic network compared to lithium disilicate implant-supported hybrid abutment crowns after 12 months of follow-up. METHODOLOGY: 44 patients were enrolled. They were randomly assigned into two groups (n = 22). The first group received 22 implants restored with polymer-infiltrated ceramic network (Vitaenamic) hybrid abutment crowns. The second group received 22 implants restored with lithium disilicate (e.max) hybrid abutment crowns over immediately placed implants in the esthetic zone. Periapical radiographs were taken immediately after prosthetic placement and 1 year later utilizing a parallel technique, to assess crestal bone loss. Periodontal parameters were assessed after 1 year. RESULTS: Regarding crestal bone loss, a comparison between group I (Vitaenamic) and group II (e.max) was made by using an Independent t-test, which showed an insignificant difference between them (p > 0.05). A comparison between groups I and II revealed insignificant differences regarding periodontal parameters (probing depth, bleeding on probing, visible plaque, and suppuration). CONCLUSIONS: Regarding bone stability and periodontal parameters, polymer infiltrated ceramic network and lithium disilicate hybrid abutment crowns showed comparable results. Both materials showed clinically acceptable hard and soft tissue responses.


Assuntos
Implantes Dentários , Estética Dentária , Humanos , Porcelana Dentária , Coroas , Cerâmica , Desenho Assistido por Computador , Zircônio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...