Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
1.
Int Dent J ; 2024 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-39384442

RESUMO

INTRODUCTION AND AIMS: With the increasing prevalence of dentin hypersensitivity, more and more desensitizing agents with tubule-occluding properties are advocated in the market. The aim of the present study was to investigate the deposition of these agents on the dentin surface under in-situ conditions. METHODS: Bovine dentin specimens were pretreated with phosphoric acid and fixed to individual upper splints that were carried by up to 2 subjects for 3 min to allow pellicle formation. The desensitizing agents containing either calcium carbonate and arginine, casein-phosphopeptide amorphous calcium phosphate, zinc-carbonate hydroxyapatite, tetracalcium phosphate and dicalcium phosphate anhydrous or hydroxyapatite nanoparticles were applied ex situ. Specimens without treatment served as controls. After a further 6 h of intraoral exposure, specimens were removed and analysed by scanning (n = 4 specimens per substance, in total) and transmission electron microscopy (n = 2 specimens per substance). RESULTS: Application of desensitizing agents resulted in the deposition of different structures on the dentin surface and occlusion of dentinal tubules. CONCLUSION: The ultrastructural analysis using transmission electron microscopy indicates that dentinal tubules were occluded under in-situ conditions not only by inorganic but also by organic deposits from the oral cavity.

2.
J Oral Biosci ; 2024 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-39304059

RESUMO

OBJECTIVE: Potassium nitrate (KNO3) suppresses nociception induced by dental hypersensitivity (HYS). We aimed to examine the effects of KNO3 on the neural activity of the trigeminal spinal subnucleus caudalis (Vc) in HYS model rats. METHODS: KNO3 or vehicle was applied to the exposed dentin of HYS rats for 3 days. c-Fos expression and neuronal activity in the Vc after acetone treatment for cold stimulation were examined to evaluate the effects of KNO3 application on dentin. RESULTS: The number of c-Fos-immunoreactive cells in the Vc was lower in the group that received KNO3 (KNO3 group) than in the group that received vehicle (control group). Spike firing of Vc neurons in response to cold stimulation of the dentin was recorded before and after KNO3 application to the cavity, and the increased neural activity was effectively suppressed by KNO3 application. Scanning electron microscopy revealed that the dentin tubules were not occluded by deposits in any of the groups. CONCLUSIONS: KNO3-induced suppression of Vc neuronal activity does not involve physical occlusion of the dentin tubules but likely involves suppression of Aδ or C-fiber activities in the tooth pulp, resulting in the suppression of Vc neuronal activities.

3.
J Esthet Restor Dent ; 36(10): 1426-1436, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38867494

RESUMO

OBJECTIVE: To evaluate the influence of air-abrasion of enamel with three different desensitizing powders on the whitening effect of a bleaching gel containing 40% H2O2, which was used for in-office tooth bleaching. MATERIALS AND METHODS: Forty human incisors, extracted and prepared, were acquired for this study and subsequently randomized into four groups (n = 10). The control group specimens underwent no pretreatment prior to the bleaching procedure, whereas the remaining three groups underwent air abrasion using distinct desensitizing powders; (a) Sylc, which contains bioglass 45S5; (b) BioMinF, which contains calcium phospho-fluoro-silicate glass; and (c) MI Pearls, which contains nano-hydroxyapatite, 1 h preceding the Opalescence Boost PF 40% bleaching procedure. Color measurements were conducted using a double-beam UV-Vis spectrophotometer at four distinct time points (prior to bleaching, 24 h, 15 days, and 30 days post-bleaching). RESULTS: Tooth color change outcomes revealed that there were no statistically significant results with respect to the interaction of the two criteria (treatments and time) (p = 0.990). Additionally, there were no statistically significant results with respect to the main effects of treatments (p = 0.385), while there were statistically significant effects with respect to the time criterion (p = 0.013). CONCLUSIONS: The use of the tested desensitizing powders prior the bleaching procedure did not affect the tooth color change induced by the tested bleaching agent. CLINICAL SIGNIFICANCE: Tooth color change and whiteness are not affected by air-abrasion desensitizing treatments when applied prior to in-office bleaching procedures.


Assuntos
Clareamento Dental , Humanos , Clareamento Dental/métodos , Abrasão Dental por Ar/métodos , Dessensibilizantes Dentinários/uso terapêutico , Peróxido de Hidrogênio
4.
Odontology ; 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38769194

RESUMO

This research aims to evaluate the efficiency of cavitary varnishes containing experimental bioglasses in the occlusion of dentinal tubules. One hundred and sixty-eight cervical buccal dentin samples were obtained from bovine teeth. Samples were randomized into the following groups: I. Distilled Water (DW); II. Cavity Varnish (CV); III. Colgate® Sensitive Pro-Relief™ (CS); IV. 45S5 Bioglass (45S5); V. KSr Bioglass strontium potassium (KSr); VI. P Bioglass phosphorus (P); and VII. PSi Bioglass phosphorus silica (PSi). The treatments were applied to the surfaces of the samples, which were then subjected to simulated brushing. The samples were analyzed for a) characterization of bioactive glasses; b) surface roughness; c) descriptive analysis of the dentin surface; d) total versus occluded number of dentinal tubules; e) diameter of the dentinal tubules; f) chemical composition of the dentin surfaces, and g) dentin permeability. All groups treated with biomaterials without the brushing challenge showed an increase in roughness and (total or partial) occlusion of the dentinal tubules. The PSi group had the best values for occlusion, while the KSr group had the highest calcium and phosphorus concentrations. After the brushing challenge the roughness was controlled by the presence of biomaterials; 45S5, KSr, and PSi showed occlusion of the dentin tubules. All bioactive glasses showed reduced tooth permeability compared to distilled water. The PSi group had the smallest tubule diameter and highest phosphorus concentration. KSr and PSi bioglasses are promising materials for dentin occlusion and remineralization and are promising new biomaterials for the treatment of dentin hypersensitivity.

5.
BMC Oral Health ; 24(1): 607, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38789946

RESUMO

BACKGROUND: This study aimed to evaluate dentin wear and biological performance of desensitizing materials. METHODS: Seventy bovine root dentin blocks were sectioned. Half of the surface of each specimen was untreated (control) and the other half was immersed in EDTA and treated with the following desensitizing materials: placebo varnish (PLA), fluoride varnish (FLU), sodium fluoride (NaF) varnish + sodium trimetaphosphate (TMP), universal adhesive (SBU), S-PRG varnish (SPRG), biosilicate (BIOS), and amelotin solution (AMTN). After application, the specimens were submitted to an erosive-abrasive challenge and the wear analyzed by optical profilometer. Serial dilutions of extracts obtained from the culture medium containing discs impregnated with those desensitizers were applied on fibroblasts and odontoblasts-like cells cultures. Cytotoxicity and production of total protein (TP) by colorimetric assays were determined after 24 h. Data were statistically analyzed using Kruskal-Wallis, Dunn's, One-way ANOVA and Tukey tests (p ≤ 0.05). RESULTS: No dentin wear was observed only for SBU. The lowest dentin wear was observed for AMTN and TMP. Cell viability was significantly reduced after treatment with undiluted extracts of PLA, FLU, TMP and SBU in fibroblasts and TMP and SBU in odontoblast-like cells. SPRG, BIOS and AMTN were cytocompatible at all dilutions tested. Considering TP results, no statistical difference was observed among the groups and high levels for TP were observed after TMP and FLU treatments. CONCLUSIONS: Universal adhesive system may protect dentin with opened tubules from wear after challenge. Extracts of adhesive and fluoride varnishes presented cytotoxic mainly on fibroblasts. The enamel protein may be a future alternative to treat dentin with opened tubules because it may cause low wear under erosive-abrasive challenge with low cytotoxic effects.


Assuntos
Dessensibilizantes Dentinários , Dentina , Fluoreto de Sódio , Animais , Bovinos , Dessensibilizantes Dentinários/farmacologia , Fluoreto de Sódio/farmacologia , Dentina/efeitos dos fármacos , Fluoretos Tópicos/farmacologia , Fibroblastos/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Desgaste dos Dentes , Teste de Materiais , Polifosfatos/farmacologia
6.
J Contemp Dent Pract ; 25(1): 52-57, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38514431

RESUMO

AIM: The aim of this study was to assess the impact of Nd:YAG laser, glutaraldehyde-based desensitizer (GD), or their combination on occluding dentinal tubules. MATERIALS AND METHODS: Fifty dentin samples were obtained from non-carious human third molars and randomly divided into five groups (n = 10): (1) Control group treated with 37% phosphoric acid, (2) GD group, (3) Nd:YAG laser group (1064 nm, 100 µs, 10 Hz, 300 µm fiber, 1 W power, 100 mJ energy, and 85 J/cm2 energy density), (4) GD followed by Nd:YAG laser group, and (5) Nd:YAG laser followed by GD group. Scanning electron microscopy (SEM) was used to capture five images from each sample for analysis of dentinal tubules using Image J software. SEM/EDX elemental analysis was performed to determine the main mineral contents. Data analyzed using one-way ANOVA and Tukey's post hoc test for statistical comparisons. RESULTS: Laser and combination groups showed a significant decrease in dentinal tubule counts compared with the control and GD groups (p < 0.0001). There were no significant differences in open dentinal tubule counts between the control and GD groups, as well as between the laser and combination groups. However, significant differences were observed in the total area, average size of the tubules, and percentage area between the control group and the treatment groups (GD, laser, GD + laser, laser + GD). No significant difference was found in the Ca/P ratio between the tested groups. CONCLUSION: The use of Nd:YAG laser alone or in combination with GD was more effective in occluding dentinal tubules compared to GD alone. CLINICAL SIGNIFICANCE: This study has shown that Nd:YAG laser alone and in combination with GD has superior dentinal tubule occlusion in vitro. Its clinical use in the treatment of dentinal hypersensitivity may overcome the drawback of conventional treatment approaches for dentin hypersensitivity needing repeated applications to achieve continuous relief from pain since acidic diet and toothbrushing result in the continuing elimination of precipitates and surface coatings. How to cite this article: Alzarooni AH, El-Damanhoury HM, Aravind SS, et al. Combined Effects of Glutaraldehyde-based Desensitizer and Nd: YAG Laser on Dentinal Tubules Occlusion. J Contemp Dent Pract 2024;25(1):52-57.


Assuntos
Sensibilidade da Dentina , Lasers de Estado Sólido , Humanos , Lasers de Estado Sólido/uso terapêutico , Dentina , Sensibilidade da Dentina/tratamento farmacológico , Glutaral/farmacologia , Glutaral/uso terapêutico , Dente Serotino , Microscopia Eletrônica de Varredura
7.
Cureus ; 16(1): e51463, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38298297

RESUMO

Introduction Dental erosion from acidogenic diets, vigorous tooth brushing, excessive tooth whitening, gingival recession, periodontal debridement, or surgery may induce dentine hypersensitivity (DH). It manifests as a phenomenon observed in structurally intact teeth devoid of pathological or defective conditions. Hence, this study aimed to evaluate DH risk reduction after using Fluoraphat Pro (Neumunster, Germany) and VivaSens® (Ivoclar Vivadent, Schaan, Liechtenstein, Switzerland) in-office desensitizing agents. Method Twenty-two participants with at least two hypersensitive teeth were randomly selected. Participants were divided into two groups with 22 teeth each, and a desensitizing agent (Fluoraphat Pro and Vivasens) was applied accordingly. Participants were recalled the next day, and a decrease in sensitivity (if any) was evaluated by self-reporting using a 5-point Likert-type scale. Relative Risk (RR) was used to compare the likelihood of sensitivity between two groups and Cohen's d to measure the effect size. A value of p<0.05 was considered significant for all statistical purposes. Result The relative risk (RR) results indicated that Fluoraphat Pro has significantly lower RR than Vivasens for patients with dental sensitivity (RR = 0.350, 95% CI 0.187 - 0.654, z = 3.28, p = 0.001). Fluoraphat Pro was significantly more effective concerning lower sensitivity in teeth located in the upper right (dCohen = 3.217, p = 0.038) and lower right (dCohen = 3.193, p = 0.017) of the mouth than VivaSens®. Conclusion The two commercially available desensitizing agents Fluoraphat Pro and Vivasens tested in this study were effective in controlling DH. Fluoraphat Pro was more efficient in relieving the risk of dental hypersensitivity than VivaSens®. Further research is needed to evaluate the long-term effects of the desensitizing agents and compare DH reduction with other marketed desensitizing products.

8.
J Periodontol ; 95(2): 135-145, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37475476

RESUMO

BACKGROUND: Evidence on the efficacy of calcium sodium phosphosilicate (CSPS) and arginine dentifrices on reducing root sensitivity (RS) following non-surgical periodontal therapy (NSPT) is limited. The aim of this study was to compare the efficacy of these dentifrices in reducing RS during daily activities in patients undergoing NSPT. METHODS: Using a double-blind randomized controlled trial, CSPS, arginine, or control dentifrices were randomly assigned to 45 RS individuals following NSPT. The participants used the dentifrices 2×/day for 8 weeks. A self-reported visual analog scale (VAS) was assessed during daily activities. RESULTS: Self-reported VAS scores were similar among the three groups at each time point. The with-in group analysis revealed that the arginine dentifrice reduced RS from Week 1-8 compared with baseline in response to cold. Similarly, the CSPS dentifrice reduced RS at Week 4 and 8. The CSPS and arginine dentifrices exhibited RS relief resulting from toothbrushing starting at Week 4 and 2, respectively. In response to air, RS relief was observed from Week 4 in the arginine group. The number of patients with VAS > 2 in response to cold declined at Week 2 and 4 in the CSPS and arginine groups, respectively. In response to toothbrushing, only 10% in the test groups still had RS at Week 8. In response to air, the number of RS patients only in the arginine group decreased at Week 4. CONCLUSION: The CSPS and arginine dentifrices provided comparable RS relief during daily activities within 2-4 weeks and remained effective up to 8 weeks.


Assuntos
Dentifrícios , Humanos , Dentifrícios/uso terapêutico , Arginina/uso terapêutico , Medição da Dor , Autorrelato , Escovação Dentária
9.
Braz. dent. j ; Braz. dent. j;35: e24, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1564088

RESUMO

Abstract The aim of this clinical, prospective, randomized, and parallel study was to evaluate different in-office treatments for dentin hypersensitivity (DH). One hundred ninety-two teeth with non-cavitated root exposures were treated using different desensitizers: fluoride varnish (Duraphat - FLU); bioactive ceramic solution (Biosilicate - BIOS); universal self-etching adhesive (Single Bond Universal - SBU); bioactive photoactivated varnish (PRG filler - SPRG). The degree of DH was analyzed using a visual analog scale (VAS) and computerized visual scale (CoVAS), before treatments and after 7, 15, and 30 days from the first session. Comparisons among desensitizers were performed using the Kruskal-Wallis and Dunn's tests. Friedman test was used to compare between times (p ≤ 0.05). Comparing desensitizers FLU presented a higher value of DH than BIOS using VAS at 7 days, however, no differences were found using CoVAS analysis. Comparing times, BIOS and SBU showed a reduction in DH after 7 days and SBU showed a reduction at 30 days compared to 7 days using VAS. FLU and SPRG groups reduced DH from 15 days to 30 days using VAS. There was a reduction in DH for FLU, BIOS, and SBU after 7 days and for BIOS this reduction also occurred at 30 days when compared to 15 days using CoVAS. SPRG group showed a reduction from 15 to 30 days. All desensitizers tested were able to reduce the initial sensitivity. The bioactive ceramic solution reduced the DH gradually after 30 days using computerized analysis.


Resumo O objetivo deste estudo clínico, prospectivo, randomizado e paralelo foi avaliar diferentes tratamentos em consultório para hipersensibilidade dentinária (HD). Cento e noventa e dois dentes com exposições radiculares não cavitadas foram tratados com diferentes dessensibilizantes: verniz fluoretado (Duraphat - FLU); solução cerâmica bioativa (Biosilicato - BIOS); adesivo autocondicionante universal (Single Bond Universal - SBU); verniz fotoativado bioativo (PRG filler - SPRG). O grau de HD foi analisado por meio da escala visual analógica (VAS) e da escala visual computadorizada (CoVAS), antes dos tratamentos e após 7, 15 e 30 dias da primeira sessão. As comparações entre dessensibilizantes foram feitas pelos testes de Kruskal-Wallis e Dunn. O teste de Friedman foi utilizado para comparação entre os tempos (p ≤ 0,05). Comparando os dessensibilizantes, o FLU apresentou um valor de HD maior do que o BIOS usando VAS aos 7 dias, no entanto, nenhuma diferença foi encontrada usando a análise CoVAS. Comparando os tempos, BIOS e SBU apresentaram redução de HD após 7 dias e SBU apresentou redução aos 30 dias em comparação com 7 dias usando VAS. Os grupos FLU e SPRG reduziram a HD em 15 dias a 30 dias usando VAS. Houve redução de HD para FLU, BIOS e SBU após 7 dias e para BIOS essa redução também ocorreu aos 30 dias quando comparada a 15 dias usando CoVAS. O grupo SPRG apresentou redução de 15 para 30 dias. Todos os dessensibilizantes testados foram capazes de reduzir a sensibilidade inicial. A solução de cerâmica bioativa reduziu o HD gradualmente após 30 dias usando análise computadorizada.

10.
J Dent Educ ; 87(12): 1705-1717, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37650366

RESUMO

OBJECTIVES: Dentin hypersensitivity (DH) affects patients' oral health-related quality of life, but is not always optimally treated in dental offices. The objectives were to assess dentists' DH-related education, knowledge, and professional behavior and explore relationships between education, knowledge, and behavior. METHODS: Survey data were collected from 220 ADA members in the United States. Descriptive and correlational analyses were performed. RESULTS: About half of the respondents agreed/strongly agreed that their dental school had educated them well about diagnosing DH in classroom-based (53.6%) and clinical settings (48.9%). Lower percentages agreed being well educated about treating DH (40.9%/37.3%). The majority self-educated themselves about DH after dental school by attending continuing education courses in person or online (60.6%/36.8%), reading articles (64.1%), or consulting with colleagues (59.6%). The majority knew that patients with DH describe their pain as stimulated (91.4%) and that recessed gingiva (89.6%), abrasion lesions (72.3%), tooth whitening (63.1%), erosion lesions (58.6%), and abfraction lesions (51.4%) are risk factors for DH. The majority diagnosed DH with patient self-reporting, confirmed by exams (81.8%), applying air blasts (53.7%), or cold-water (52.3%). They treated patients with DH often/very often with over-the-counter desensitizing agents (90%), and prescribing fluoride formulations toothpaste (82.8%) and/or potassium nitrate toothpastes (60.9%). In their offices, the majority (73.2%) educated their patients often/very often about DH and used fluoride dental varnish for treating DH (71.8%). The more recently respondents had graduated from dental school, the more positively they described their dental school education (r = 0.14; p < 0.05), the more ways to diagnose DH they used (r = 0.16; p < 0.05) and the more often they used fluoride dental varnish in their offices (r = 0.23; p < 0.001). The more dentists had educated themselves, the more methods for diagnosing DH they used (r = 0.23; p < 0.001) and the more often they used potassium oxalate products (r = 0.19; p < 0.01), Arginine/calcium products (r = 0.19; p < 0.01) and dentin bonding (r = 0.22; p < 0.001). CONCLUSIONS: More recently graduating from dental school correlates with more positive evaluations of DH-related dental school education. The finding that most dentists engage in self-education about DH after dental school should motivate dental educators to increase education about this topic not only in dental school, but also in continuing education courses.


Assuntos
Sensibilidade da Dentina , Fluoretos , Humanos , Fluoretos/uso terapêutico , Sensibilidade da Dentina/diagnóstico , Sensibilidade da Dentina/tratamento farmacológico , Qualidade de Vida , Escolaridade , Cremes Dentais/uso terapêutico , Odontólogos , Resultado do Tratamento
11.
Bioengineering (Basel) ; 10(4)2023 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-37106634

RESUMO

Dentin hypersensitivity (DH) pain is a persistent clinical problem, which is a common condition known to affect patients' quality of life (QoL), but no treatment has ever been agreed upon. Calcium phosphates, available in different forms, have properties that allow sealing the dentinal tubules, which may relieve dentin hypersensitivity. The aim of this systematic review is to evaluate the ability of different formulations of calcium phosphate to reduce dentin hypersensitivity pain level in clinical studies. The inclusion criterion was as follows: clinical randomized controlled studies using calcium phosphates in treating dentin hypersensitivity. In December 2022, three electronic databases (Pubmed, Cochrane and Embase) were searched. The search strategy was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. The bias assessment risks results were carried out using the Cochrane Collaboration tool. A total of 20 articles were included and analyzed in this systematic review. The results show that calcium phosphates have properties that reduce DH-associated pain. Data compilation showed a statistically significant difference in DH pain level between T0 and 4 weeks. This VAS level reduction is estimated at about -2.5 compared to the initial level. The biomimetic and non-toxic characteristics of these materials make them a major asset in treating dentin hypersensitivity.

12.
Lasers Med Sci ; 38(1): 103, 2023 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-37069368

RESUMO

The aim of this study was the evaluation of the in vitro efficacy of a carbon dioxide (CO2) laser, a tetracalcium phosphate/dicalcium phosphate anhydrate (TP/DP) desensitizer and the combination of the desensitizer and additional CO2 laser irradiation as a treatment modality for cervical dentin hypersensitivity. A total of 48 dental specimens, prepared from extracted human premolars and molars, were divided into four groups: a control group, a TP/DP desensitizer paste group, a CO2 laser (10.600-nm wavelength) group, and a paste and laser group. The specimens were coated with nail varnish except in the marked area and were then immersed in 2% methylene blue dye for 1 h. The specimens were then washed, dried, and cut longitudinally. Thereafter, photos of 40 dentin specimens were taken and evaluated. The area of penetration was assessed and reported as percentage of the dentin surface area. Additionally eight dental specimens were examined with the aid of a scanning electron microscope and evaluated. Significant differences in the penetration depth were found for all experimental groups compared to the control group. The lowest penetration area was detected in the paste-laser group (16.5%), followed by the laser (23.7%), the paste (48.5%), and the control group (86.2%). The combined treatment of the CO2 laser and a TP/DP desensitizer was efficient in sealing the dentinal surface and could be a treatment option for cervical dentin hypersensitivity.


Assuntos
Sensibilidade da Dentina , Dentina , Humanos , Dentina/efeitos da radiação , Sensibilidade da Dentina/tratamento farmacológico , Sensibilidade da Dentina/radioterapia , Dióxido de Carbono/farmacologia , Microscopia Eletrônica de Varredura , Lasers
13.
Cureus ; 15(2): e35214, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36968862

RESUMO

Background Dentinal hypersensitivity (DH) is a common clinical finding that varies greatly in prevalence. An appropriate impulse that detonates noxious stimuli in the pulp/dentin boundary causes the typical DH pain, which is sudden, short, sharp, and of rapid onset. The objective of this research was to ascertain the incidence of DH in Keralites and evaluate some contributory factors, along with other initiating stimuli. Methodology Over three months, from June 2022 to August 2022, a cluster sampling technique was employed to conduct the study in 14 districts of Kerala. Patients from five clinics from each district who reported having DH and were aged 25 to 65 years were chosen at random. Using Google Survey forms, a 20-question, closed-ended survey was mailed to patients. The data were collected, evaluated, and analyzed using SPSS Version 23.0 (IBM Corp., Armonk, NY, USA). The statistical difference in the distribution of DH and the patient's age was determined using analysis of variance (ANOVA). A chi-square test was carried out to test the association between dentinal hypersensitivity, gender, and other parameters; P < 0.05 was considered to be statistically significant. Results Among the 2,520 persons to whom questionnaires were mailed, 2,321 responded, with an unresponsive rate of 7.89%. The study revealed a sensitivity predilection among females (54%), although statistically insignificant. Respondents aged 25 to 35 years (41.01%) were commonly reported to have DH, the age distribution of which was found to be highly significant statistically (P < 0.01). Teeth whitening resulted in 82.98% of the sensitivity, whereas 47.99% accepted poor oral hygiene as an additional contributory factor. DH was reported in 52.01% of the patients with gastritis and 63.03% of the patients with gingival recession. Further, blame for poor dental treatment (88.88%) and climate change (82.92%) were also found relevant. The quality of life was claimed to be afflicted in 90.99% of the patients. Desensitizing agents were used by 68.97% of the patients, with which 68.03% reported satisfaction. Of the subjects who underwent professional treatment, 87.03% reported being satisfied. Oral prophylaxis-induced sensitivity was reported in 57.99%, indicating enhanced oral health awareness among Kerala residents. There was a statistically highly significant difference in the patient distribution based on the exposure to DH, and their perception of the causes and factors affecting DH (P < 0.01). Conclusions DH is a frequently and widely prevalent dental malady. Respondents demonstrated that they were conversant with DH. The quality of life and enjoyment of daily activities are both impacted by dentin hypersensitivity, and many patients are unaware that it is a treatable illness. Various desensitizing substances are also available and can be applied quickly to sensitive areas. Patients prefer this procedure as it is simpler to apply these agents and the effects are pleasant and beneficial.

14.
J Am Dent Assoc ; 154(3): 245-259.e12, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36717350

RESUMO

BACKGROUND: Topical application of calcium-containing bioactive desensitizers (CBs) has been used to minimize bleaching-induced tooth sensitivity (TS). This study answered the research question "Is the risk of TS lower when CBs are used with dental bleaching in adults compared with bleaching without desensitizers?" TYPES OF STUDIES REVIEWED: The authors included randomized clinical trials comparing topical CB application with a placebo or no intervention during bleaching. Searches for eligible articles were performed in MEDLINE via PubMed, Cochrane Library, Brazilian Library in Dentistry, Latin American and Caribbean Health Sciences Literature, Scopus, Web of Science, Embase, and gray literature without language and date restrictions and updated in September 2022. The risk of bias was evaluated using Risk of Bias Version 2.0. The authors conducted meta-analyses with the random-effects model. The authors assessed heterogeneity with the Cochrane Q test, I2 statistics, and prediction interval. The authors used the Grading of Recommendations Assessment, Development and Evaluation approach to assess the certainty of the evidence. RESULTS: After database screening, 22 studies remained, with most at high risk of bias. No difference in the risk of TS was detected (risk ratio, 0.95; 95% CI, 0.90 to 1.01; P = .08, low certainty). In a visual analog scale, the intensity of TS (mean difference, -0.98; 95% CI, -1.36 to -0.60; P < .0001, very low certainty) was lower for the CB group. The color change was unaffected (P > .08). PRACTICAL IMPLICATIONS: Although topical CB dental bleaching did not reduce the risk of TS and color change, these agents slightly reduced the TS intensity, but the certainty of the evidence is very low.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Adulto , Humanos , Clareadores Dentários/uso terapêutico , Cálcio/efeitos adversos , Sensibilidade da Dentina/tratamento farmacológico , Brasil
15.
Clin Oral Investig ; 27(4): 1567-1576, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36418502

RESUMO

OBJECTIVES: To evaluate the risk and intensity of tooth sensitivity (TS), and the efficacy of in-office bleaching after applying an experimental desensitizing gel composed of 10% calcium gluconate, 0.1% dexamethasone acetate, 10% potassium nitrate, and 5% glutaraldehyde. MATERIAL AND METHODS: In a split-mouth, double-blind, placebo-controlled study, 50 participants had their upper hemiarches randomized into experimental and placebo groups. Desensitizing and placebo gels were applied for 10 min before in-office bleaching (35% hydrogen peroxide, 1 × 50 min; two bleaching sessions; 1-week interval). TS was recorded immediately after bleaching, 1, 24, and 48 h after each session, with a 0-10 visual analogue scale (VAS) and a five-point numerical rating scale (NRS). The color was recorded in all groups at baseline, 1 week after each session, and 1 month after the end of bleaching using shade guide units (ΔSGUs) and a spectrophotometer (ΔEab, ΔE00, and ΔWID). RESULTS: Most participants (96%) felt some discomfort during treatment regardless of the study group. The odds ratio for pain was 0.65 (95% CI 0.1 to 4.1; p = 1.0). The intensity of TS did not differ between groups (p > 0.31), and it was only 0.34 VAS units lower in the experimental group. A significant color change occurred in both groups regardless of the group. CONCLUSIONS: The desensitizing experimental gel applied before in-office bleaching did not reduce the risk and the intensity of TS and did not affect color change. CLINICAL RELEVANCE: Although the experimental desensitizing agent with varying mechanisms of action did not jeopardize the color change, it did not reduce the risk or intensity of in-office bleaching. CLINICAL TRIAL REGISTRATION NUMBER: RBR-7T7D4D.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Humanos , Sensibilidade da Dentina/induzido quimicamente , Sensibilidade da Dentina/prevenção & controle , Clareadores Dentários/efeitos adversos , Peróxido de Hidrogênio/efeitos adversos , Ácido Hipocloroso , Géis/efeitos adversos , Resultado do Tratamento
16.
Pesqui. bras. odontopediatria clín. integr ; 23: e220124, 2023. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-1529133

RESUMO

ABSTRACT Objective: To identify the 100 most-cited articles in DH and analyze their characteristics. Material and Methods: A search was performed on the Web of Science (WoS) and the 100 most-cited articles were selected. The following data were extracted: citations, year of publication, authorship, institution, country, journal, language, study design, topic of interest, conflict of interest (COI), and sponsorship. The VOSviewer software was used to visualize bibliometric networks. Poisson regression analysis was performed to measure associations between several citations and the characteristics of the studies. Results: The number of citations ranged from 346 to 48. The most-cited article was published in 1997 by Holland in the Journal of Clinical Periodontology. This journal published the most papers, followed by the Journal of Oral Rehabilitation and Journal of Dentistry. Laboratory research, review, and clinical trial were the study designs most prevalent. Reviews (p<0.05; PR= 1.853) and method development studies (p<0.05; PR= 1.853) had a more chance to present more citations. The main topics of interest were the clinical effectiveness of desensitizers and in vitro analysis of dentin morphology. Sponsorship and COI were underreported. England and USA presented the greatest number of citations and connections in the coauthorship network map. Conclusion: Most of the articles were original research, and their topics of interest were mainly the clinical effectiveness of desensitizing agents and dentin morphology.


Assuntos
Bibliometria , Sensibilidade da Dentina , Dessensibilizantes Dentinários , Distribuição de Poisson , Estudos Transversais/métodos
17.
Cureus ; 15(12): e50990, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38259360

RESUMO

Background and objectives Dentin hypersensitivity (DH) treatment is one of the main challenges dentists face in their daily clinical practice. Current therapies provide only temporary relief and require multiple applications to exhibit results, and there is a lack of evidence related to the long-term effects of these agents. Nano-hydroxyapatite (n-HA) and pro-argin (8.0% arginine-calcium carbonate) have recently been used for dentin desensitization with a one-time in-office application, but the effects are interim. However, a standard treatment protocol demands definitive or enduring results. Since iontophoresis amplifies the transport of neutral and ionized drugs across a membrane, the use of these desensitizing agents with iontophoresis may be beneficial to accomplish satisfactory results. This study was conducted to evaluate whether iontophoresis could enable better penetration of nano-hydroxyapatite and pro-argin into the dentin, enhancing and prolonging their therapeutic effect. Materials and methods Forty-five participants with dentin hypersensitivity in the age group of 20 to 60 years were included. In each individual, four teeth with cervical lesions (one from each quadrant) were selected and divided randomly into four groups: group I: desensitizing paste containing nano-hydroxyapatite, group II: desensitizing paste containing nano-hydroxyapatite with iontophoresis, group III: desensitizing paste containing pro-argin, and group IV: desensitizing paste containing pro-argin with iontophoresis; followed by one-time application of the agents. Sensitivity was assessed by tactile, air blast, and cold-graded thermal tests (CGTTs) before and immediately after application, after one week, and at the end of the first, third, and sixth months. Statistical analysis Statistical analysis was done by repeated measures ANOVA for within-group comparison. Intergroup comparison was done using one-way ANOVA and Tukey's post-hoc test. Results All the groups showed a statistically significant reduction in dentin hypersensitivity (p<0.001). The reduction in hypersensitivity in various groups can be graded as group II (3.578/1.800/1.556) > group IV (3.367/1.755/1.555) > group I (2.3781/1.022/0.822) > group III (2.222/0.911/0.778) as evaluated by tactile, air blast, and cold-graded thermal tests, respectively. Group II and group IV presented a significant reduction in sensitivity levels consistent for up to six months. Conclusion Nano-hydroxyapatite and pro-argin can be used effectively for reducing dentin hypersensitivity. Iontophoresis can be a valuable adjunct for their improved delivery, enhancing and prolonging their effectiveness.

18.
J Conserv Dent Endod ; 26(6): 682-687, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38292733

RESUMO

Aim: The aim of this study was to assess the effectiveness of two various in-office newer desensitizing agents in reducing dentinal hypersensitivity in patients with mild-to-moderate sensitivity for a 1-month follow-up. Materials and Methods: Forty subjects with cervical dentin hypersensitivity (otherwise healthy patients) were included. A split-mouth, randomized clinical trial was conducted. A Visual Analog Scale (VAS) was used to record the initial sensitivity levels at the baseline visit. Each individual has been exposed to thermal (ethyl chloride spray) and evaporative (air blast) stimuli to elicit sensitivity. A single application of two different in-office desensitizing agents, Clinpro XT Varnish (3M ESPE, Minnesota, USA) and Shield Force Plus (Tokuyama Dental, Tokyo, Japan), was done. The sensitivity scores were recorded after the application of the desensitizing agent immediately, after 1 week, and after 1 month using both air and cold stimuli in the same manner as initially. Results: Mean VAS scores represent teeth that were more sensitive to cold stimuli compared to air blasts in both groups. For both stimuli at all-time intervals except baseline, there is a significant difference between CXT and SFP, with low mean VAS scores for CXT. Post hoc analysis revealed that in the CXT group, there is a significant difference in mean VAS score between pre-and postintervention at all-time intervals except between immediate and 1-week time intervals (P < 0.001) but only at immediate and 1-week time intervals in SFP. Conclusion: Clinpro XT Varnish is more efficient compared to Shield Force Plus at all-time points irrespective of the stimuli after a 1-month follow-up.

19.
Acta odontol. latinoam ; Acta odontol. latinoam;35(3): 229-237, Dec. 2022. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1419950

RESUMO

ABSTRACT Dentin hypersensitivity (DH) is characterized by rapid, acute pain arising from exposed dental tubules. Aim: the aim of this study was to evaluate the roughness, tubule occlusion, and permeability of eroded dentin brushed with different toothpastes. Materials and Method: ninety bovine teeth were cut into blocks. Thirty hemifaces were protected with varnish and the other sixty were submitted to permeability tests. Specimens were divided into groups according to the dentifrices: without fluoride (WF), sodium fluoride (NaF), and stannous fluoride (SnF2). The blocks were subjected to a 5-day erosive-abrasive protocol. Surface roughness and dentinal tubule occlusion (n=10) were assessed for both control and test hemifaces of the same sample along with permeability analysis (n=20). Two-way RM ANOVA and Tukey's post-hoc test were performed (p≤0.05). Results: NaF and SnF2 presented higher roughness than WF. The number of open tubules was higher in WF. Permeability was higher in SnF2, but there was no significant difference between WF and NaF. Conclusions: both fluoride toothpastes occluded dentinal tubules and increased roughness. NaF toothpaste promoted greater decrease in dentin permeability.


RESUMO A hipersensibilidade dentinária (HD) é caracterizada por dor rápida e aguda decorrente de túbulos dentais expostos. Objetivo: este estudo teve como objetivo avaliar a rugosidade, oclusão tubular e permeabilidade da dentina erodida escovada com diferentes dentifrícios. Materiais e Método: noventa dentes bovinos foram seccionados em blocos. Trinta hemifaces foram protegidas com verniz e outras sessenta foram submetidas à permeabilidade. Os espécimes foram divididos em grupos de acordo com os dentifrícios: sem flúor (SF), fluoreto de sódio (NaF) e fluoreto estanoso (SnF2). Em seguida, os blocos foram submetidos a um protocolo erosivo-abrasivo de 5 dias. A rugosidade da superfície e a oclusão do túbulo dentinário (n = 10) foram avaliadas para ambas as hemifaces de controle e teste da mesma amostra, também realizou-se a análise de permeabilidade (n = 20). Two-way RM ANOVA e pós-teste de Tukey foram realizados (p≤0,05). Resultados: NaF e SnF2 apresentaram rugosidade superior ao SF. O número de túbulos abertos foi maior em SF. Não encontramos diferenças significativas entre SF e NaF em relação à permeabilidade; entretanto, SnF2 apresentou maior permeabilidade. Conclusão: ambos os dentifrícios fluoretados foram capazes de ocluir os túbulos dentinários e aumentar a rugosidade. No entanto, o dentifrício NaF promoveu uma maior diminuição da permeabilidade dentinária.

20.
Dent Mater ; 38(10): 1669-1678, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36089408

RESUMO

OBJECTIVES: To characterize the behavior of three different polymeric agents before and after an erosive challenge on dentin permeability, to analyze their degradation in both conditions, and to analyze their degree of conversion (DC). METHODS: The permeability of human dentin disks (1.0 ± 0.2 mm) was measured with smear layer, after its removal, after treatment (LpTreat) with Gluma Desensitizer, PRG Barrier Coat (PBC) or Icon infiltrant (n = 11/group) and after exposure to citric acid (LpEro) (6%, pH 2.1, 1 min). The specimens were analyzed under a Laser Scanning Confocal Microscope (n = 2/group) and the products' DC were calculated. Data were subjected to 2-way repeated measures ANOVA and post-hoc Bonferroni (permeability analysis), to paired t-test (for specimens treated with Icon) and to t-test (DC analysis) (α < 0.05). RESULTS: Icon showed the lowest LpTreat and LpEro values, while PBC and Gluma did not differ from each other under these conditions. Icon and PBC showed LpEro similar to a dentin with smear layer. Under the Laser Scanning Confocal Microscope, more deposits were noticeable on dentin after treating with PBC. Gluma presented the deepest penetration in dentin. The DC of PBC was the highest. SIGNIFICANCE: Icon caused the highest reduction on permeability values, followed by PBC and Gluma. PBC generated more deposits covering dentin and seemed to be more efficient after an erosive challenge. The association of a polymeric resin with inorganic ion-releasing fillers seem to be a great strategy to manage dentin hypersensitivity under erosive conditions.


Assuntos
Dessensibilizantes Dentinários , Sensibilidade da Dentina , Camada de Esfregaço , Ácido Cítrico/farmacologia , Dentina , Dessensibilizantes Dentinários/química , Permeabilidade da Dentina , Glutaral/farmacologia , Humanos , Microscopia Confocal , Microscopia Eletrônica de Varredura , Ácidos Polimetacrílicos , Espectroscopia de Infravermelho com Transformada de Fourier
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...