Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 255
Filtrar
1.
Magn Reson Med ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38968132

RESUMO

PURPOSE: To reduce the ringing artifacts of the motion-resolved images in free-breathing dynamic pulmonary MRI. METHODS: A golden-step based interleaving (GSI) technique was proposed to reduce ringing artifacts induced by diaphragm drifting. The pulmonary MRI data were acquired using a superior-inferior navigated 3D radial UTE sequence in an interleaved manner during free breathing. Successive interleaves were acquired in an incoherent fashion along the polar direction. Four-dimensional images were reconstructed from the motion-resolved k-space data obtained by retrospectively binning. The reconstruction algorithms included standard nonuniform fast Fourier transform (NUFFT), Voronoi-density-compensated NUFFT, extra-dimensional UTE, and motion-state weighted motion-compensation reconstruction. The proposed interleaving technique was compared with a conventional sequential interleaving (SeqI) technique on a phantom and eight subjects. RESULTS: The quantified ringing artifacts level in the motion-resolved image is positively correlated with the quantified nonuniformity level of the corresponding k-space. The nonuniformity levels of the end-expiratory and end-inspiratory k-space binned from GSI data (0.34 ± 0.07, 0.33 ± 0.05) are significantly lower with statistical significance (p < 0.05) than that binned from SeqI data (0.44 ± 0.11, 0.42 ± 0.12). Ringing artifacts are substantially reduced in the dynamic images of eight subjects acquired using the proposed technique in comparison with that acquired using the conventional SeqI technique. CONCLUSION: Ringing artifacts in the motion-resolved images induced by diaphragm drifting can be reduced using the proposed GSI technique for free-breathing dynamic pulmonary MRI. This technique has the potential to reduce ringing artifacts in free-breathing liver and kidney MRI based on full-echo interleaved 3D radial acquisition.

2.
NMR Biomed ; : e5209, 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38994704

RESUMO

Phase-resolved functional lung (PREFUL) MRI is a proton-based, contrast agent-free technique derived from the Fourier decomposition approach to measure regional ventilation and perfusion dynamics during free-breathing. Besides the necessity of extensive PREFUL postprocessing, the utilized MRI sequence must fulfill specific requirements. This study investigates the impact of sequence selection on PREFUL-MRI-derived functional parameters by comparing the standard spoiled gradient echo (SPGRE) sequence with a lung-optimized balanced steady-state free precession (bSSFP) sequence, thereby facilitating PREFULs clinical application in pulmonary disease assessment. This study comprised a prospective dataset of healthy volunteers and a retrospective dataset of patients with suspected chronic thromboembolic pulmonary hypertension. Both cohorts underwent PREFUL-MRI with both sequences to assess the correspondence of PREFUL ventilation and perfusion parameters (A). Additionally, healthy subjects were scanned a second time to evaluate repeatability (B), whereas patients received dynamic contrast-enhanced (DCE)-MRI, considered the perfusion gold standard for comparison with PREFUL-MRI (C). Signal-to-noise ratio (SNR), calculated from the unprocessed images, was compared alongside median differences of PREFUL-MRI-derived parameters using a paired Wilcoxon signed rank test. Further evaluations included calculation of the Pearson correlation, intraclass-correlation coefficient for repeatability assessment, and spatial overlap (SO) for regional comparison of PREFUL-MRI and DCE-MRI. bSSFP showed a clear SNR advantage over SPGRE (median: 23 vs. 9, p < 0.001). (A) Despite significant differences, parameter values were strongly correlated (r ≥ 0.75). After thresholding, binary maps showed high healthy overlap across both cohorts (SOHealthy > 86%) and high defect overlap in the patient cohort (SODefect ≥ 48%). (B) bSSFP demonstrated slightly higher repeatability across most parameters. (C) Both sequences demonstrated comparable correspondence to DCE-MRI, with SPGRE excelling in absolute quantification and bSSFP in spatial agreement. Although bSSFP showed superior SNR results, both sequences displayed spatial defect concordance and highly correlated PREFUL parameters with deviations regarding repeatability and alignment with DCE-MRI.

3.
Radiol Cardiothorac Imaging ; 6(4): e230262, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39051878

RESUMO

Purpose To investigate free-breathing thoracic bright-blood four-dimensional (4D) dynamic MRI (dMRI) to characterize aeration of parenchymal lung tissue in healthy children and patients with thoracic insufficiency syndrome (TIS). Materials and Methods All dMR images in patients with TIS were collected from July 2009 to June 2017. Standardized signal intensity (sSI) was investigated, first using a lung aeration phantom to establish feasibility and sensitivity and then in a retrospective research study of 40 healthy children (16 male, 24 female; mean age, 9.6 years ± 2.1 [SD]), 20 patients with TIS before and after surgery (11 male, nine female; mean age, 6.2 years ± 4.2), and another 10 healthy children who underwent repeated dMRI examinations (seven male, three female; mean age, 9 years ± 3.6). Individual lungs in 4D dMR images were segmented, and sSI was assessed for each lung at end expiration (EE), at end inspiration (EI), preoperatively, postoperatively, in comparison to normal lungs, and in repeated scans. Results Air content changes of approximately 6% were detectable in phantoms via sSI. sSI within phantoms significantly correlated with air occupation (Pearson correlation coefficient = -0.96 [P < .001]). For healthy children, right lung sSI was significantly lower than that of left lung sSI (at EE: 41 ± 6 vs 47 ± 6 and at EI: 39 ± 6 vs 43 ± 7, respectively; P < .001), lung sSI at EI was significantly lower than that at EE (P < .001), and left lung sSI at EE linearly decreased with age (r = -0.82). Lung sSI at EE and EI decreased after surgery for patients (although not statistically significantly, with P values of sSI before surgery vs sSI after surgery, left and right lung separately, in the range of 0.13-0.51). sSI varied within 1.6%-4.7% between repeated scans. Conclusion This study demonstrates the feasibility of detecting change in sSI in phantoms via bright-blood dMRI when air occupancy changes. The observed reduction in average lung sSI after surgery in pediatric patients with TIS may indicate postoperative improvement in parenchymal aeration. Keywords: MR Imaging, Thorax, Lung, Pediatrics, Thoracic Surgery, Lung Parenchymal Aeration, Free-breathing Dynamic MRI, MRI Intensity Standardization, Thoracic Insufficiency Syndrome Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Pulmão , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Humanos , Masculino , Feminino , Criança , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem , Estudos Retrospectivos , Insuficiência Respiratória/diagnóstico por imagem , Respiração , Síndrome , Pré-Escolar , Imageamento Tridimensional/métodos
4.
MAGMA ; 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39039272

RESUMO

OBJECTIVE: To review the recent advancements in free-breathing MRI techniques for proton-density fat fraction (PDFF) and R2* quantification in the liver, and discuss the current challenges and future opportunities. MATERIALS AND METHODS: This work focused on recent developments of different MRI pulse sequences, motion management strategies, and reconstruction approaches that enable free-breathing liver PDFF and R2* quantification. RESULTS: Different free-breathing liver PDFF and R2* quantification techniques have been evaluated in various cohorts, including healthy volunteers and patients with liver diseases, both in adults and children. Initial results demonstrate promising performance with respect to reference measurements. These techniques have a high potential impact on providing a solution to the clinical need of accurate liver fat and iron quantification in populations with limited breath-holding capacity. DISCUSSION: As these free-breathing techniques progress toward clinical translation, studies of the linearity, bias, and repeatability of free-breathing PDFF and R2* quantification in a larger cohort are important. Scan acceleration and improved motion management also hold potential for further enhancement.

5.
J Magn Reson Imaging ; 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39036994

RESUMO

BACKGROUND: Conventional liver magnetic resonance elastography (MRE) requires breath-holding (BH) to avoid motion artifacts, which is challenging for children. While radial free-breathing (FB)-MRE is an alternative for quantifying liver stiffness (LS), previous methods had limitations of long scan times, acquiring two slices in 5 minutes, and not resolving motion during reconstruction. PURPOSE: To reduce FB-MRE scan time to 4 minutes for four slices and to investigate the impact of self-gated (SG) motion compensation on FB-MRE LS quantification in terms of agreement, intrasession repeatability, and technical quality compared to conventional BH-MRE. STUDY TYPE: Prospective. POPULATION: Twenty-six children without fibrosis (median age: 12.9 years, 15 females). FIELD STRENGTH/SEQUENCE: 3 T; Cartesian gradient-echo (GRE) BH-MRE, research application radial GRE FB-MRE. ASSESSMENT: Participants were scanned twice to measure repeatability, without moving the table or changing the participants' position. LS was measured in areas of the liver with numerical confidence ≥90%. Technical quality was examined using measurable liver area (%). STATISTICAL TESTS: Agreement of LS between BH-MRE and FB-MRE was evaluated using Bland-Altman analysis for SG acceptance rates of 40%, 60%, 80%, and 100%. LS repeatability was assessed using within-subject coefficient of variation (wCV). The differences in LS and measurable liver area were examined using Kruskal-Wallis and Wilcoxon signed-rank tests. P < 0.05 was considered significant. RESULTS: FB-MRE with 60% SG achieved the closest agreement with BH-MRE (mean difference 0.00 kPa). The LS ranged from 1.70 to 1.83 kPa with no significant differences between BH-MRE and FB-MRE with varying SG rates (P = 0.52). All tested methods produced repeatable LS with wCV from 4.4% to 6.5%. The median measurable liver area was smaller for FB-MRE (32%-45%) than that for BH-MRE (91%-93%) (P < 0.05). DATA CONCLUSION: FB-MRE with 60% SG can quantify LS with close agreement and comparable repeatability with respect to BH-MRE in children. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.

6.
J Cardiovasc Magn Reson ; 26(2): 101065, 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39059610

RESUMO

BACKGROUND: Quantitative myocardial tissue characterization with T1 and T2 parametric mapping can provide an accurate and complete assessment of tissue abnormalities across a broad range of cardiomyopathies. However, current clinical T1 and T2 mapping tools rely predominantly on two-dimensional (2D) breath-hold sequences. Clinical adoption of three-dimensional (3D) techniques is limited by long scan duration. The aim of this study is to develop and validate a time-efficient 3D free-breathing simultaneous T1 and T2 mapping sequence using multi-parametric SAturation-recovery and Variable-flip-Angle (mSAVA). METHODS: mSAVA acquires four volumes for simultaneous whole-heart T1 and T2 mapping. We validated mSAVA using simulations, phantoms, and in-vivo experiments at 3T in 11 healthy subjects and 11 patients with diverse cardiomyopathies. T1 and T2 values by mSAVA were compared with modified Look-Locker inversion recovery (MOLLI) and gradient and spin echo (GraSE), respectively. The clinical performance of mSAVA was evaluated against late gadolinium enhancement (LGE) imaging in patients. RESULTS: Phantom T1 and T2 by mSAVA showed a strong correlation to reference sequences (R2 = 0.98 and 0.99). In-vivo imaging with an imaging resolution of 1.5 × 1.5 × 8 mm3 could be achieved. Myocardial T1 and T2 of healthy subjects by mSAVA were 1310 ± 46 and 44.6 ± 2.0 ms, respectively, with T1 standard deviation higher than MOLLI (105 ± 12 vs 60 ± 16 ms) and T2 standard deviation lower than GraSE (4.5 ± 0.8 vs 5.5 ± 1.0 ms). mSAVA T1 and T2 maps presented consistent findings in patients undergoing LGE. Myocardial T1 and T2 of all patients by mSAVA were 1421 ± 79 and 47.2 ± 3.3 ms, respectively. CONCLUSION: mSAVA is a fast 3D technique promising for clinical whole-heart T1 and T2 mapping.

7.
Magn Reson Med ; 2024 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-38923009

RESUMO

PURPOSE: Quantitative T1 mapping has the potential to replace biopsy for noninvasive diagnosis and quantitative staging of chronic liver disease. Conventional T1 mapping methods are confounded by fat and B 1 + $$ {B}_1^{+} $$ inhomogeneities, resulting in unreliable T1 estimations. Furthermore, these methods trade off spatial resolution and volumetric coverage for shorter acquisitions with only a few images obtained within a breath-hold. This work proposes a novel, volumetric (3D), free-breathing T1 mapping method to account for multiple confounding factors in a single acquisition. THEORY AND METHODS: Free-breathing, confounder-corrected T1 mapping was achieved through the combination of non-Cartesian imaging, magnetization preparation, chemical shift encoding, and a variable flip angle acquisition. A subspace-constrained, locally low-rank image reconstruction algorithm was employed for image reconstruction. The accuracy of the proposed method was evaluated through numerical simulations and phantom experiments with a T1/proton density fat fraction phantom at 3.0 T. Further, the feasibility of the proposed method was investigated through contrast-enhanced imaging in healthy volunteers, also at 3.0 T. RESULTS: The method showed excellent agreement with reference measurements in phantoms across a wide range of T1 values (200 to 1000 ms, slope = 0.998 (95% confidence interval (CI) [0.963 to 1.035]), intercept = 27.1 ms (95% CI [0.4 54.6]), r2 = 0.996), and a high level of repeatability. In vivo imaging studies demonstrated moderate agreement (slope = 1.099 (95% CI [1.067 to 1.132]), intercept = -96.3 ms (95% CI [-82.1 to -110.5]), r2 = 0.981) compared to saturation recovery-based T1 maps. CONCLUSION: The proposed method produces whole-liver, confounder-corrected T1 maps through simultaneous estimation of T1, proton density fat fraction, and B 1 + $$ {B}_1^{+} $$ in a single, free-breathing acquisition and has excellent agreement with reference measurements in phantoms.

8.
Magn Reson Med ; 92(4): 1511-1524, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38872384

RESUMO

PURPOSE: To develop and validate a highly efficient motion compensated free-breathing isotropic resolution 3D whole-heart joint T1/T2 mapping sequence with anatomical water/fat imaging at 0.55 T. METHODS: The proposed sequence takes advantage of shorter T1 at 0.55 T to acquire three interleaved water/fat volumes with inversion-recovery preparation, no preparation, and T2 preparation, respectively. Image navigators were used to facilitate nonrigid motion-compensated image reconstruction. T1 and T2 maps were jointly calculated by a dictionary matching method. Validations were performed with simulation, phantom, and in vivo experiments on 10 healthy volunteers and 1 patient. The performance of the proposed sequence was compared with conventional 2D mapping sequences including modified Look-Locker inversion recovery and T2-prepared balanced steady-SSFP sequence. RESULTS: The proposed sequence has a good T1 and T2 encoding sensitivity in simulation, and excellent agreement with spin-echo reference T1 and T2 values was observed in a standardized T1/T2 phantom (R2 = 0.99). In vivo experiments provided good-quality co-registered 3D whole-heart T1 and T2 maps with 2-mm isotropic resolution in a short scan time of about 7 min. For healthy volunteers, left-ventricle T1 mean and SD measured by the proposed sequence were both comparable with those of modified Look-Locker inversion recovery (640 ± 35 vs. 630 ± 25 ms [p = 0.44] and 49.9 ± 9.3 vs. 54.4 ± 20.5 ms [p = 0.42]), whereas left-ventricle T2 mean and SD measured by the proposed sequence were both slightly lower than those of T2-prepared balanced SSFP (53.8 ± 5.5 vs. 58.6 ± 3.3 ms [p < 0.01] and 5.2 ± 0.9 vs. 6.1 ± 0.8 ms [p = 0.03]). Myocardial T1 and T2 in the patient measured by the proposed sequence were in good agreement with conventional 2D sequences and late gadolinium enhancement. CONCLUSION: The proposed sequence simultaneously acquires 3D whole-heart T1 and T2 mapping with anatomical water/fat imaging at 0.55 T in a fast and efficient 7-min scan. Further investigation in patients with cardiovascular disease is now warranted.


Assuntos
Tecido Adiposo , Imageamento Tridimensional , Imagens de Fantasmas , Humanos , Imageamento Tridimensional/métodos , Masculino , Tecido Adiposo/diagnóstico por imagem , Adulto , Coração/diagnóstico por imagem , Reprodutibilidade dos Testes , Algoritmos , Feminino , Imageamento por Ressonância Magnética/métodos , Respiração , Água Corporal/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Voluntários Saudáveis
9.
Magn Reson Med Sci ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38763758

RESUMO

PURPOSE: To evaluate how the relationship between respiratory interval (RI) and temporal resolution (TR) impacts image quality in free-breathing abdominal MRI (FB-aMRI) using golden-angle radial sparse parallel (GRASP). METHODS: Ten healthy volunteers (25.9 ± 2.5 years, four women) underwent 2 mins free-breathing fat-suppression T1-weighted imaging using GRASP at RIs of 3 and 5s (RI3 and RI5, respectively) and retrospectively reconstructed at TR of 1.8, 2.9, 4.8, and 7.7s (TR1.8, TR2.9, TR4.8, and TR7.7, respectively) in each patient. The standard deviation (SD) under the diaphragm was measured using SD maps showing the discrepancy for each horizontal section at all TRs. Two radiologists evaluated image quality (visualization of the right hepatic vein at the confluence of the inferior vena cava, posterior segment branch of portal vein, pancreas, left kidney, and artifacts) at all TRs using a 5-point scale. RESULTS: The SD was significantly higher at TR1.8 compared to TR4.8 (P < 0.01) and TR7.7 (P < 0.001), as well as at TR2.9 compared to TR7.7 (P < 0.01) for both RIs. The SD between TR4.8 and TR7.7 did not differ for both RIs. For all visual assessment metrics, the TR1.8 scores were significantly lower than the TR4.8 and TR7.7 scores for both RIs. The pancreas and left kidney scores at TR2.9 were significantly lower than those at TR7.7 (P < 0.05) for RI5. Additionally, the left kidney score at TR1.8 was lower than that at TR2.9 (P < 0.05) for RI3. All scores at TR2.9, TR4.8, and TR7.7 were similar for RI3, while those at TR4.8 and TR7.7 were similar for RI5. CONCLUSION: Prolonging the TRs compared to RIs enhances image quality in FB-aMRI using GRASP.

10.
Quant Imaging Med Surg ; 14(4): 2884-2903, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38617145

RESUMO

Background: Multi-echo chemical-shift-encoded magnetic resonance imaging (MRI) has been widely used for fat quantification and fat suppression in clinical liver examinations. Clinical liver water-fat imaging typically requires breath-hold acquisitions, with the free-breathing acquisition method being more desirable for patient comfort. However, the acquisition for free-breathing imaging could take up to several minutes. The purpose of this study is to accelerate four-dimensional free-breathing whole-liver water-fat MRI by jointly using high-dimensional deep dictionary learning and model-guided (MG) reconstruction. Methods: A high-dimensional model-guided deep dictionary learning (HMDDL) algorithm is proposed for the acceleration. The HMDDL combines the powers of the high-dimensional dictionary learning neural network (hdDLNN) and the chemical shift model. The neural network utilizes the prior information of the dynamic multi-echo data in spatial respiratory motion, and echo dimensions to exploit the features of images. The chemical shift model is used to guide the reconstruction of field maps, R2∗ maps, water images, and fat images. Data acquired from ten healthy subjects and ten subjects with clinically diagnosed nonalcoholic fatty liver disease (NAFLD) were selected for training. Data acquired from one healthy subject and two NAFLD subjects were selected for validation. Data acquired from five healthy subjects and five NAFLD subjects were selected for testing. A three-dimensional (3D) blipped golden-angle stack-of-stars multi-gradient-echo pulse sequence was designed to accelerate the data acquisition. The retrospectively undersampled data were used for training, and the prospectively undersampled data were used for testing. The performance of the HMDDL was evaluated in comparison with the compressed sensing-based water-fat separation (CS-WF) algorithm and a parallel non-Cartesian recurrent neural network (PNCRNN) algorithm. Results: Four-dimensional water-fat images with ten motion states for whole-liver are demonstrated at several R values. In comparison with the CS-WF and PNCRNN, the HMDDL improved the mean peak signal-to-noise ratio (PSNR) of images by 9.93 and 2.20 dB, respectively, and improved the mean structure similarity (SSIM) of images by 0.058 and 0.009, respectively, at R=10. The paired t-test shows that there was no significant difference between HMDDL and ground truth for proton-density fat fraction (PDFF) and R2∗ values at R up to 10. Conclusions: The proposed HMDDL enables features of water images and fat images from the highly undersampled multi-echo data along spatial, respiratory motion, and echo dimensions, to improve the performance of accelerated four-dimensional (4D) free-breathing water-fat imaging.

11.
Radiol Cardiothorac Imaging ; 6(2): e230104, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38573129

RESUMO

Purpose To assess the feasibility of monitoring the effects of elexacaftor-tezacaftor-ivacaftor (ETI) therapy on lung ventilation and perfusion in people with cystic fibrosis (CF), using phase-resolved functional lung (PREFUL) MRI. Materials and Methods This secondary analysis of a multicenter prospective study was carried out between August 2020 and March 2021 and included participants 12 years or older with CF who underwent PREFUL MRI, spirometry, sweat chloride test, and lung clearance index assessment before and 8-16 weeks after ETI therapy. For PREFUL-derived ventilation and perfusion parameter extraction, two-dimensional coronal dynamic gradient-echo MR images were evaluated with an automated quantitative pipeline. T1- and T2-weighted MR images and PREFUL perfusion maps were visually assessed for semiquantitative Eichinger scores. Wilcoxon signed rank test compared clinical parameters and PREFUL values before and after ETI therapy. Correlation of parameters was calculated as Spearman ρ correlation coefficient. Results Twenty-three participants (median age, 18 years [IQR: 14-24.5 years]; 13 female) were included. Quantitative PREFUL parameters, Eichinger score, and clinical parameters (lung clearance index = 21) showed significant improvement after ETI therapy. Ventilation defect percentage of regional ventilation decreased from 18% (IQR: 14%-25%) to 9% (IQR: 6%-17%) (P = .003) and perfusion defect percentage from 26% (IQR: 18%-36%) to 19% (IQR: 13%-24%) (P = .002). Areas of matching normal (healthy) ventilation and perfusion increased from 52% (IQR: 47%-68%) to 73% (IQR: 61%-83%). Visually assessed perfusion scores did not correlate with PREFUL perfusion (P = .11) nor with ventilation-perfusion match values (P = .38). Conclusion The study demonstrates the feasibility of PREFUL MRI for semiautomated quantitative assessment of perfusion and ventilation changes in response to ETI therapy in people with CF. Keywords: Pediatrics, MR-Functional Imaging, Pulmonary, Lung, Comparative Studies, Cystic Fibrosis, Elexacaftor-Tezacaftor-Ivacaftor Therapy, Fourier Decomposition, PREFUL, Free-Breathing Proton MRI, Pulmonary MRI, Perfusion, Functional MRI, CFTR, Modulator Therapy, Kaftrio Clinical trial registration no. NCT04732910 Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Aminofenóis , Benzodioxóis , Fibrose Cística , Indóis , Pirazóis , Piridinas , Pirrolidinas , Quinolonas , Adolescente , Feminino , Humanos , Fibrose Cística/diagnóstico por imagem , Estudos de Viabilidade , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Perfusão , Estudos Prospectivos , Respiração , Masculino , Adulto Jovem
12.
Diagn Interv Radiol ; 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38578150

RESUMO

Obtaining diagnostic-quality magnetic resonance imaging (MRI) of the abdomen in critically ill patients can be difficult due to challenges with breath-holding and the inability to follow technologist instructions. Protocols that harness advances in commercially available MRI techniques provide a potential solution, particularly using the golden radial angle sparse parallel (GRASP) technique for dynamic post-contrast T1-weighted imaging. The GRASP technique uses a combination of free-breathing, a stack-of-stars radial acquisition, and compressed sensing reconstruction acquired over several minutes to produce motion-free images at time points defined by the user; these include the non-contrast, arterial, venous, and delayed images, which are typical of abdominal MRI protocols. The three cases discussed herein illustrate the use of this technique in providing both exquisite image quality and diagnostic value in the care of critically ill patients with hepatopancreaticobiliary diseases. Our work aims to raise awareness of this technique and its utility in imaging patients who cannot hold their breath for dynamic T1-weighted post-contrast imaging.

13.
Magn Reson Med ; 92(2): 586-604, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38688875

RESUMO

PURPOSE: Abdominal imaging is frequently performed with breath holds or respiratory triggering to reduce the effects of respiratory motion. Diffusion weighted sequences provide a useful clinical contrast but have prolonged scan times due to low signal-to-noise ratio (SNR), and cannot be completed in a single breath hold. Echo-planar imaging (EPI) is the most commonly used trajectory for diffusion weighted imaging but it is susceptible to off-resonance artifacts. A respiratory resolved, three-dimensional (3D) diffusion prepared sequence that obtains distortionless diffusion weighted images during free-breathing is presented. Techniques to address the myriad of challenges including: 3D shot-to-shot phase correction, respiratory binning, diffusion encoding during free-breathing, and robustness to off-resonance are described. METHODS: A twice-refocused, M1-nulled diffusion preparation was combined with an RF-spoiled gradient echo readout and respiratory resolved reconstruction to obtain free-breathing diffusion weighted images in the abdomen. Cartesian sampling permits a sampling density that enables 3D shot-to-shot phase navigation and reduction of transient fat artifacts. Theoretical properties of a region-based shot rejection are described. The region-based shot rejection method was evaluated with free-breathing (normal and exaggerated breathing), and respiratory triggering. The proposed sequence was compared in vivo with multishot DW-EPI. RESULTS: The proposed sequence exhibits no evident distortion in vivo when compared to multishot DW-EPI, robustness to B0 and B1 field inhomogeneities, and robustness to motion from different respiratory patterns. CONCLUSION: Acquisition of distortionless, diffusion weighted images is feasible during free-breathing with a b-value of 500 s/mm2, scan time of 6 min, and a clinically viable reconstruction time.


Assuntos
Abdome , Artefatos , Imagem de Difusão por Ressonância Magnética , Imageamento Tridimensional , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Abdome/diagnóstico por imagem , Imageamento Tridimensional/métodos , Respiração , Algoritmos , Razão Sinal-Ruído , Reprodutibilidade dos Testes , Interpretação de Imagem Assistida por Computador/métodos
14.
Magn Reson Imaging ; 109: 42-48, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38447629

RESUMO

PURPOSE: To evaluate the performance of high-resolution free-breathing (FB) hepatobiliary phase imaging of the liver using the eXtra-Dimension Golden-angle RAdial Sparse Parallel (XD-GRASP) MRI technique. METHODS: Fifty-eight clinical patients (41 males, mean age = 52.9 ± 12.9) with liver lesions who underwent dynamic contrast-enhanced MRI with a liver-specific contrast agent were prospectively recruited for this study. Both breath-hold volumetric interpolated examination (BH-VIBE) imaging and FB imaging were performed during the hepatobiliary phase. FB images were acquired using a stack-of-stars golden-angle radial sequence and were reconstructed using the XD-GRASP method. Two experienced radiologists blinded to acquisition schemes independently scored the overall image quality, liver edge sharpness, hepatic vessel clarity, conspicuity of lesion, and overall artifact level of each image. The non-parametric paired two-tailed Wilcoxon signed-rank test was used for statistical analysis. RESULTS: Compared to BH-VIBE images, XD-GRASP images received significantly higher scores (P < 0.05) for the liver edge sharpness (4.83 ± 0.45 vs 4.29 ± 0.46), the hepatic vessel clarity (4.64 ± 0.67 vs 4.15 ± 0.56) and the conspicuity of lesion (4.75 ± 0.53 vs 4.31 ± 0.50). There were no significant differences (P > 0.05) between BH-VIBE and XD-GRASP images for the overall image quality (4.61 ± 0.50 vs 4.74 ± 0.47) and the overall artifact level (4.13 ± 0.44 vs 4.05 ± 0.61). CONCLUSION: Compared to conventional BH-VIBE MRI, FB radial acquisition combined with XD-GRASP reconstruction facilitates higher spatial resolution imaging of the liver during the hepatobiliary phase. This enhancement can significantly improve the visualization and evaluation of the liver.


Assuntos
Interpretação de Imagem Assistida por Computador , Respiração , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Interpretação de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Suspensão da Respiração , Meios de Contraste , Artefatos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos
15.
J Cardiovasc Magn Reson ; 26(1): 101037, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38499269

RESUMO

BACKGROUND: Free-running cardiac and respiratory motion-resolved whole-heart five-dimensional (5D) cardiovascular magnetic resonance (CMR) can reduce scan planning and provide a means of evaluating respiratory-driven changes in clinical parameters of interest. However, respiratory-resolved imaging can be limited by user-defined parameters which create trade-offs between residual artifact and motion blur. In this work, we develop and validate strategies for both correction of intra-bin and compensation of inter-bin respiratory motion to improve the quality of 5D CMR. METHODS: Each component of the reconstruction framework was systematically validated and compared to the previously established 5D approach using simulated free-running data (N = 50) and a cohort of 32 patients with congenital heart disease. The impact of intra-bin respiratory motion correction was evaluated in terms of image sharpness while inter-bin respiratory motion compensation was evaluated in terms of reconstruction error, compression of respiratory motion, and image sharpness. The full reconstruction framework (intra-acquisition correction and inter-acquisition compensation of respiratory motion [IIMC] 5D) was evaluated in terms of image sharpness and scoring of image quality by expert reviewers. RESULTS: Intra-bin motion correction provides significantly (p < 0.001) sharper images for both simulated and patient data. Inter-bin motion compensation results in significant (p < 0.001) lower reconstruction error, lower motion compression, and higher sharpness in both simulated (10/11) and patient (9/11) data. The combined framework resulted in significantly (p < 0.001) sharper IIMC 5D reconstructions (End-expiration (End-Exp): 0.45 ± 0.09, End-inspiration (End-Ins): 0.46 ± 0.10) relative to the previously established 5D implementation (End-Exp: 0.43 ± 0.08, End-Ins: 0.39 ± 0.09). Similarly, image scoring by three expert reviewers was significantly (p < 0.001) higher using IIMC 5D (End-Exp: 3.39 ± 0.44, End-Ins: 3.32 ± 0.45) relative to 5D images (End-Exp: 3.02 ± 0.54, End-Ins: 2.45 ± 0.52). CONCLUSION: The proposed IIMC reconstruction significantly improves the quality of 5D whole-heart MRI. This may be exploited for higher resolution or abbreviated scanning. Further investigation of the diagnostic impact of this framework and comparison to gold standards is needed to understand its full clinical utility, including exploration of respiratory-driven changes in physiological measurements of interest.


Assuntos
Artefatos , Cardiopatias Congênitas , Interpretação de Imagem Assistida por Computador , Valor Preditivo dos Testes , Humanos , Reprodutibilidade dos Testes , Feminino , Masculino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Adulto , Adulto Jovem , Imageamento por Ressonância Magnética , Adolescente , Mecânica Respiratória , Técnicas de Imagem de Sincronização Respiratória , Criança , Pessoa de Meia-Idade , Respiração , Imagem Cinética por Ressonância Magnética
16.
NMR Biomed ; 37(8): e5134, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38459747

RESUMO

Free-breathing abdominal chemical exchange saturation transfer (CEST) has great potential for clinical application, but its technical implementation remains challenging. This study aimed to propose and evaluate a free-breathing abdominal CEST sequence. The proposed sequence employed respiratory gating (ResGat) to synchronize the data acquisition with respiratory motion and performed a water presaturation module before the CEST saturation to abolish the influence of respiration-induced repetition time variation. In vivo experiments were performed to compare different respiratory motion-control strategies and B0 offset correction methods, and to evaluate the effectiveness and necessity of the quasi-steady-state (QUASS) approach for correcting the influence of the water presaturation module on CEST signal. ResGat with a target expiratory phase of 0.5 resulted in a higher structural similarity index and a lower coefficient of variation on consecutively acquired CEST S0 images than breath-holding (BH) and respiratory triggering (all p < 0.05). B0 maps derived from the abdominal CEST dataset itself were more stable for B0 correction, compared with the separately acquired B0 maps by a dual-echo time scan and B0 maps derived from the water saturation shift referencing approach. Compared with BH, ResGat yielded more homogeneous magnetization transfer ratio asymmetry maps at 3.5 ppm (standard deviation: 3.96% vs. 3.19%, p = 0.036) and a lower mean squared difference between scan and rescan (27.52‱ vs. 16.82‱, p = 0.004). The QUASS approach could correct the water presaturation-induced CEST signal change, but its necessity for in vivo scanning needs further verification. The proposed free-breathing abdominal CEST sequence using ResGat had an acquisition efficiency of approximately four times that using BH. In conclusion, the proposed free-breathing abdominal CEST sequence using ResGat and water presaturation has a higher acquisition efficiency and image quality than abdominal CEST using BH.


Assuntos
Abdome , Imageamento por Ressonância Magnética , Respiração , Técnicas de Imagem de Sincronização Respiratória , Água , Abdome/diagnóstico por imagem , Humanos , Água/química , Técnicas de Imagem de Sincronização Respiratória/métodos , Masculino , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino
17.
J Magn Reson Imaging ; 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38485244

RESUMO

BACKGROUND: Postacute Covid-19 patients commonly present with respiratory symptoms; however, a noninvasive imaging method for quantitative characterization of respiratory patterns is lacking. PURPOSE: To evaluate if quantitative characterization of respiratory pattern on free-breathing higher temporal resolution MRI stratifies patients by cardiopulmonary symptom burden. STUDY TYPE: Prospective analysis of retrospectively acquired data. SUBJECTS: A total of 37 postacute Covid-19 patients (25 male; median [interquartile range (IQR)] age: 58 [42-64] years; median [IQR] days from acute infection: 335 [186-449]). FIELD STRENGTH/SEQUENCE: 0.55 T/two-dimensional coronal true fast imaging with steady-state free precession (trueFISP) at higher temporal resolution. ASSESSMENT: Patients were stratified into three groups based on presence of no (N = 11), 1 (N = 14), or ≥2 (N = 14) cardiopulmonary symptoms, assessed using a standardized symptom inventory within 1 month of MRI. An automated lung postprocessing workflow segmented each lung in each trueFISP image (temporal resolution 0.2 seconds) and respiratory curves were generated. Quantitative parameters were derived including tidal lung area, rates of inspiration and expiration, lung area coefficient of variability (CV), and respiratory incoherence (departure from sinusoidal pattern) were. Pulmonary function tests were recorded if within 1 month of MRI. Qualitative assessment of respiratory pattern and lung opacity was performed by three independent readers with 6, 9, and 23 years of experience. STATISTICAL TESTS: Analysis of variance to assess differences in demographic, clinical, and quantitative MRI parameters among groups; univariable analysis and multinomial logistic regression modeling to determine features predictive of patient symptom status; Akaike information criterion to compare the quality of regression models; Cohen and Fleiss kappa (κ) to quantify inter-reader reliability. Two-sided 5% significance level was used. RESULTS: Tidal area and lung area CV were significantly higher in patients with two or more symptoms than in those with one or no symptoms (area: 15.4 cm2 vs. 12.9 cm2 vs. 12.8 cm2 ; CV: 0.072, 0.067, and 0.058). Respiratory incoherence was significantly higher in patients with two or more symptoms than in those with one or no symptoms (0.05 vs. 0.043 vs. 0.033). There were no significant differences in patient age (P = 0.19), sex (P = 0.88), lung opacity severity (P = 0.48), or pulmonary function tests (P = 0.35-0.97) among groups. Qualitative reader assessment did not distinguish between groups and showed slight inter-reader agreement (κ = 0.05-0.11). DATA CONCLUSION: Quantitative respiratory pattern measures derived from dynamic higher-temporal resolution MRI have potential to stratify patients by symptom burden in a postacute Covid-19 cohort. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 3.

18.
Radiol Cardiothorac Imaging ; 6(1): e230107, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38358330

RESUMO

Purpose To achieve ultra-high temporal resolution (approximately 20 msec) in free-breathing, real-time cardiac cine MRI using golden-angle radial sparse parallel (GRASP) reconstruction amplified with view sharing (VS) and k-space-weighted image contrast (KWIC) filtering. Materials and Methods Fourteen pediatric patients with congenital heart disease (mean age [SD], 9 years ± 2; 13 male) and 10 adult patients with arrhythmia (mean age, 62 years ± 8; nine male) who underwent both standard breath-hold cine and free-breathing real-time cine using GRASP were retrospectively identified. To achieve high temporal resolution, each time frame was reconstructed using six radial spokes, corresponding to acceleration factors ranging from 24 to 32. To compensate for loss in spatial resolution resulting from over-regularization in GRASP, VS and KWIC filtering were incorporated. The blur metric, visual image quality scores, and biventricular parameters were compared between clinical and real-time cine images. Results In pediatric patients, the incorporation of VS and KWIC into GRASP (ie, GRASP + VS + KWIC) produced significantly (P < .05) sharper x-y-t (blur metric: 0.36 ± 0.03, 0.41 ± 0.03, 0.48 ± 0.03, respectively) and x-y-f (blur metric: 0.28 ± 0.02, 0.31 ± 0.03, 0.37 ± 0.03, respectively) component images compared with GRASP + VS and conventional GRASP. Only the noise score differed significantly between GRASP + VS + KWIC and clinical cine; all visual scores were above the clinically acceptable (3.0) cutoff point. Biventricular volumetric parameters strongly correlated (R2 > 0.85) between clinical and real-time cine images reconstructed with GRASP + VS + KWIC and were in good agreement (relative error < 6% for all parameters). In adult patients, the visual scores of all categories were significantly lower (P < .05) for clinical cine compared with real-time cine with GRASP + VS + KWIC, except for noise (P = .08). Conclusion Incorporating VS and KWIC filtering into GRASP reconstruction enables ultra-high temporal resolution (approximately 20 msec) without significant loss in spatial resolution. Keywords: Cine, View Sharing, k-Space-weighted Image Contrast Filtering, Radial k-Space, Pediatrics, Arrhythmia, GRASP, Compressed Sensing, Real-Time, Free-Breathing Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Imagem Cinética por Ressonância Magnética , Imageamento por Ressonância Magnética , Adulto , Humanos , Masculino , Criança , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquipneia , Hiperventilação , Arritmias Cardíacas
19.
Magn Reson Imaging ; 108: 40-46, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38309379

RESUMO

INTRODUCTION: Cardiac magnetic resonance imaging (MRI), including late gadolinium enhancement (LGE), plays an important role in the diagnosis and prognostication of ischemic and non-ischemic myocardial injury. Conventional LGE sequences require patients to perform multiple breath-holds and require long acquisition times. In this study, we compare image quality and assessment of myocardial LGE using an accelerated free-breathing sequence to the conventional standard-of-care sequence. METHODS: In this prospective cohort study, a total of 41 patients post Coronavirus 2019 (COVID-19) infection were included. Studies were performed on a 1.5 Tesla scanner with LGE imaging acquired using a conventional inversion recovery rapid gradient echo (conventional LGE) sequence followed by the novel accelerated free-breathing (FB-LGE) sequence. Image quality was visually scored (ordinal scale from 1 to 5) and compared between conventional and free-breathing sequences using the Wilcoxon rank sum test. Presence of per-segment LGE was identified according to the American Heart Association 16-segment myocardial model and compared across both conventional LGE and FB-LGE sequences using a two-sided chi-square test. The perpatient LGE extent was also evaluated using both sequences and compared using the Wilcoxon rank sum test. Interobserver variability in detection of per-segment LGE and per-patient LGE extent was evaluated using Cohen's kappa statistic and interclass correlation (ICC), respectively. RESULTS: The mean acquisition time for the FB-LGE sequence was 17 s compared to 413 s for the conventional LGE sequence (P < 0.001). Assessment of image quality was similar between both sequences (P = 0.19). There were no statistically significant differences in LGE assessed using the FB-LGE versus conventional LGE on a per-segment (P = 0.42) and per-patient (P = 0.06) basis. Interobserver variability in LGE assessment for FB-LGE was good for per-segment (= 0.71) and per-patient extent (ICC = 0.92) analyses. CONCLUSIONS: The accelerated FB-LGE sequence performed comparably to the conventional standard-of-care LGE sequence in a cohort of patients post COVID-19 infection in a fraction of the time and without the need for breath-holding. Such a sequence could impact clinical practice by increasing cardiac MRI throughput and accessibility for frail or acutely ill patients unable to perform breath-holding.


Assuntos
COVID-19 , Meios de Contraste , Humanos , Gadolínio , Estudos Prospectivos , Respiração , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , COVID-19/diagnóstico por imagem
20.
Magn Reson Imaging ; 108: 77-85, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38331052

RESUMO

PURPOSE: To investigate the feasibility of obtaining black-blood imaging with a large FOV from the neck to the aortic arch at 3 T using a newly modified Relaxation-Enhanced Angiography without Contrast and Triggering for Black-Blood Imaging (REACT-BB). MATERIALS AND METHODS: REACT-BB provides black-blood images by adjusting the inversion time (TI) in REACT to the null point of blood. The optimal TI for REACT-BB was investigated in 10 healthy volunteers with TI varied from 200 ms to 1400 ms. Contrast ratios were calculated between muscle and three branch arteries of the aortic arch. Additionally, a comparison between REACT-BB and MPRAGE involved evaluating the depiction of high-intensity plaques in 222 patients with stroke or transient ischemic attack. Measurements included plaque-to-muscle signal intensity ratios (PMR), plaque volumes, and carotid artery stenosis rates in 60 patients with high-intensity plaques in carotid arteries. RESULTS: REACT-BB with TI = 850 ms produced the black-blood image with the best contrast between blood and background tissues. REACT-BB outperformed MPRAGE in depicting high-intensity plaques in the aortic arch (55.4% vs 45.5%) and exhibited superior overall image quality in visual assessment (3.31 ± 0.70 vs 2.89 ± 0.73; p < 0.05). Although the PMR of REACT-BB was significantly lower than MPRAGE (2.227 ± 0.601 vs 2.285 ± 0.662; P < 0.05), a strong positive correlation existed between REACT-BB and MPRAGE (ρ = 0.935; P < 0.05), and all high-intensity plaques that MPRAGE detected were clearly detected by REACT-BB. CONCLUSION: REACT-BB provides black-blood images with uniformly suppressed fat and blood signals over a large FOV from the neck to the aortic arch with comparable or better high-signal plaque depiction than MPRAGE.


Assuntos
Estenose das Carótidas , Placa Aterosclerótica , Humanos , Estudos de Viabilidade , Aorta Torácica/diagnóstico por imagem , Artérias Carótidas , Imageamento por Ressonância Magnética/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...