Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(18)2024 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-39338755

RESUMO

Differential coils are frequently implemented in inductive sensing systems. They can be considered as a single coil that is made up of two or more subcoils, wound in series opposition. They can be used on the transmit or receive side of measurement systems, and, if designed correctly, ensure no coupling between coils under background conditions. By cancelling background coupling, the receive electronics only needs to be able to measure the change in coupling produced by a target. This allows for a more efficient use of the dynamic range, and for larger receive-side amplifier gain, thereby improving SNR. When subcoils are not electrically similar, it can be hard to engineer the coil to be perfectly balanced across a wide bandwidth. This paper presents an analytical model of a resonant differential coil pair that is tested and applied on a planar metal detector for the detection of buried objects. The model demonstrates the capability to balance an arbitrary differential coil pair, which has a broad applicability across a range of inductive sensor applications such as metal detection and non-destructive testing. The method is applied to the practical system. The results show that the correction resulting from this method ensures a stable balance across a significantly enhanced bandwidth. In the case studied here, the bandwidth of the experimental system is increased from 20 kHz to 90 kHz.

2.
Sensors (Basel) ; 23(18)2023 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-37765892

RESUMO

Recycling aluminium is essential for a circular economy, reducing the energy required and greenhouse gas emissions compared to extraction from virgin ore. A 'Twitch' waste stream is a mix of shredded wrought and cast aluminium. Wrought must be separated before recycling to prevent contamination from the impurities present in the cast. In this paper, we demonstrate magnetic induction spectroscopy (MIS) to classify wrought from cast aluminium. MIS measures the scattering of an oscillating magnetic field to characterise a material. The conductivity difference between cast and wrought makes it a promising choice for MIS. We first show how wrought can be classified on a laboratory system with 89.66% recovery and 94.96% purity. We then implement the first industrial MIS material recovery solution for sorting Twitch, combining our sensors with a commercial-scale separator system. The industrial system did not reflect the laboratory results. The analysis found three areas of reduced performance: (1) metal pieces correctly classified by one sensor were misclassified by adjacent sensors that only captured part of the metal; (2) the metal surface facing the sensor can produce different classification results; and (3) the choice of machine learning algorithm is significant with artificial neural networks producing the best results on unseen data.

3.
Sensors (Basel) ; 19(12)2019 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-31226728

RESUMO

BACKGROUND: Biomass measurement and monitoring is a challenge in a number of biotechnology processes where fast, inexpensive, and non-contact measurement techniques would be of great benefit. Magnetic induction spectroscopy (MIS) is a novel non-destructive and contactless impedance measurement technique with many potential industrial and biomedical applications. The aim of this paper is to use computer modeling and experimental measurements to prove the suitability of the MIS system developed at the University of South Wales for controlled biomass measurements. METHODS: The paper reports experimental measurements conducted on saline solutions and yeast suspensions at different concentrations to test the detection performance of the MIS system. The commercial electromagnetic simulation software CST was used to simulate the measurement outcomes with saline solutions and compare them with those of the actual measurements. We adopted two different ways for yeast suspension preparation to assess the system's sensitivity and accuracy. RESULTS: For saline solutions, the simulation results agree well with the measurement results, and the MIS system was able to distinguish saline solutions at different concentrations even in the small range of 0-1.6 g/L. For yeast suspensions, regardless of the preparation method, the MIS system can reliably distinguish yeast suspensions with lower concentrations 0-20 g/L. The conductivity spectrum of yeast suspensions present excellent separability between different concentrations and dielectric dispersion property at concentrations higher than 100 g/L. CONCLUSIONS: The South Wales MIS system can achieve controlled yeast measurements with high sensitivity and stability, and it shows promising potential applications, with further development, for cell biology research where contactless monitoring of cellular density is of relevance.


Assuntos
Biomassa , Biotecnologia , Contagem de Células/métodos , Leveduras/crescimento & desenvolvimento , Simulação por Computador , Espectroscopia Dielétrica , Campos Eletromagnéticos , Solução Salina/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...