Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 972
Filtrar
1.
J Dent ; 148: 105152, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38909643

RESUMO

OBJECTIVES: To review the developments in intraoral scanner (IOS) technologies applied in implant prosthodontics, emphasizing their influence on the accuracy of digital impressions, occlusal registrations, and the fit of implant-supported restorations. DATA: A collection of published articles related to implant prosthodontics, the accuracy of digital impressions, occlusal registration, and the fit of implant-supported fixed restorations. SOURCES: Three search engines were selected: Medline/PubMed, EBSCO, and Cochrane. A manual search was also conducted. STUDY SELECTION: A literature search screened relevant databases and journals for studies on IOS applications in digital implant prosthodontic workflows from Dec 2018 to Dec 2023. Inclusion criteria encompassed randomized control trials, clinical trials, case series, and in vitro research focused on the use of IOS in digital implant prosthodontics. CONCLUSIONS: The increased utilization of digital dental technologies has led to significant integration of digital implant prosthodontic workflows into clinicians' clinical practice. Several variables affect the accuracy of digital impressions generated by IOS. Generally, the prevailing opinion in academic papers is that digital workflows are suitable for addressing short-span implant-supported restorations. However, when it comes to long-span defects, the accuracy of digital workflows is still a matter of debate. Digital bite registration is an integral part of the workflow. It depends mainly on the defect size and location, scan strategy, anatomical tooth variations, overbite and other factors. The overall fit of digitally prefabricated implant restorations comprises of proximal, occlusal contacts and how accurately the restoration connects with implants. Research methodologies need standardization for further validation. CLINICAL SIGNIFICANCE: In clinical practice, it is essential to have a thorough and up-to-date comprehension of various factors that can affect the accuracy of digital impressions and the fit of the final prosthesis in implant prosthodontics.

2.
Cureus ; 16(5): e61051, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38916007

RESUMO

Tooth surface loss (TSL) is multifactorial and, when severe, it can severely impact the quality of life. Although carbonated soft drinks, with their high sugar and acid content, are a common cause of TSL, the effects do not usually mandate full-mouth rehabilitation. Nevertheless, when combined with other factors such as parafunctional habits or other drivers of high consumption, TSL can be severe. Here we present the case of a 35-year-old man who presented with mild to severe TSL throughout the oral cavity caused by erosion and attrition. Causative factors were heavy consumption of soft drinks for years to quench thirst caused by asthma, side effects of asthma-related medications, and other parafunctional habits. The eight-step approach was as minimally invasive as possible, considering the severe presentation of TSL, and offered the patient a more durable treatment option than previously provided resin-based composite restorations. Presenting this case allows us to discuss the causes of TSL and also describe full mouth rehabilitation of TSL at increased occlusal vertical dimension with indirect restorations. We also demonstrate the integration of removable and fixed options, when progressing complex restorative cases.

3.
Dent J (Basel) ; 12(6)2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38920865

RESUMO

Laser, an acronym for Light Amplification by Stimulated Emission of Radiation, is a powerful tool with diverse applications in modern dentistry. It emits monochromatic, coherent light resulting from photon-induced chain reactions. Available dental lasers include diode, argon, Er,Cr:YSGG, Er:YAG, Nd:YAG, and CO2. The unique property of these lasers, allowing them to be effectively used on both soft and hard tissues based on the operational parameters, positions them as particularly suited for a wide range of dental procedures. Compared to traditional methods, lasers offer advantages such as improved hemostasis and quicker wound healing. Such benefits stress the shift towards laser technology in dental treatment. In the realm of dental prosthodontics, which focuses on esthetics, functionality, and the physiological aspects of dental prostheses, lasers provide promising outcomes. Among the prosthetic options, fixed partial dentures stand out for their ability to mimic natural teeth, offering both esthetic and functional features, leading to satisfactory long-term outcomes if managed properly. This review paper delves into the specific application of laser technology in the context of prosthetic rehabilitation involving fixed partial dentures. By investigating intraoral laser procedures, it contributes to understanding laser's role in improving patients' satisfaction and clinical efficiency in this field.

4.
J Dent ; : 105135, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38885735

RESUMO

OBJECTIVES: To evaluate the accumulative effect of 3D printer, implant analog systems, and implant angulation on the accuracy of analog position in implant casts. METHODS: A reference cast, presenting a case of a three-unit implant-supported prosthesis, was scanned with a coordinate measurement machine, producing the first reference data set (CMM, n = 1). The second reference data set (n = 10) was prepared using an intraoral scanner (IOS) (Trios4). Test quadrant casts were produced using three DLP type 3D printers, Max (MAX UV385), Pro (PRO 4K65 UV), and Nex (NextDent 5100), and three implant analog systems, El (Elos), Nt (Nt-trading), and St (Straumann) (n = 90). Stone casts were also produced via analog impressions (Stone, n = 10). After digitization, the accuracy of 3D distance, local angulation (angle between implants) and global angulation (angle between the implant center axis and an axis perpendicular to the global plane) was evaluated by comparing the reference (CMM, IOS), test (3D print), and control (Stone) groups using metrology software. Data were statistically analyzed using three-way ANOVA and Tukey`s tests (α=0.05). RESULTS: IOS was truer in 3D implant distance and more precise in capturing local angulation than Stone (p ≤ 0.05). Other measurements were similar between both groups (p > 0.05). The amount of error introduced in the workflow by IOS and 3D printing was mostly similar (p > 0.05). 3D printed casts had similar or even higher accuracy than Stone group (p > 0.05). In most cases, higher trueness was achieved when using PRO 4K65 UV 3D printer and Elos implant analog system (p ≤ 0.05). CONCLUSION: 3D printer, implant analog system, and implant angulation have a significant effect on the accuracy of analog position in implant casts. Limited-span implant-supported cases could be reproduced digitally with similar accuracy as conventional methods. CLINICAL SIGNIFICANCE: A fully digital workflow with a carefully selected 3D printer and implant analog system can increase the accuracy of digitally produced implant casts with comparable accuracy to conventional workflow.

5.
J Clin Med ; 13(11)2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38893040

RESUMO

Background: In everyday dentistry, monolithic single crowns can be cemented with self-adhesive resin cements. The aim of this in vitro study was to evaluate how the marginal adaptation of full monolithic zirconia-reinforced lithium silicate (ZLS) single crowns is influenced by three different self-adhesive resin cements. Methods: Forty-five typodont teeth fully prepared for full monolithic crowns were divided into three groups (fifteen each) for the use of three different self-adhesive resin cements. A fourth control group (Temp-bond) was created by taking five teeth from each group before cementation with self-adhesive resin cements. All forty-five abutments were scanned using a Primescan intra-oral scanner (IOS), followed by computer-aided design (CAD) and computer-aided manufacturing (CAM) of zirconia-reinforced lithium silicate (ZLS) full crowns using a four-axis machine. Initially, the crowns of the control group were fixed to the abutments using Temp-bond, and the marginal gap was evaluated using a scanning electron microscope (SEM). After removing the control group crowns from the abutments, fifteen crowns in each group were cemented using a different self-adhesive resin cement and observed under SEM for evaluation of the marginal gap. A Kolmogorov-Smirnov test was performed, indicating no normal distribution (p < 0.05), followed by Mann-Whitney tests (α = 0.05). Results: The total mean marginal gap of the temp-bond control group was significantly lower compared to all three groups of self-adhesive resin cement (p < 0.0005). The total mean marginal gap of the G-cem ONE group was significantly lower compared to the TheraCem group (p < 0.026) and RelyX U200 group (p < 0.008). The total mean marginal gap of the TheraCem group was significantly higher than the G-cem ONE group (p < 0.026) but showed no significant difference with the RelyX U200 group (p > 0.110). Conclusions: All four groups showed a clinically acceptable marginal gap (<120 microns). Although all three groups of self-adhesive resin cement showed a significant increase in the marginal gap compared to the temp-bond control group, they were within the limits of clinical acceptability. Regarding the marginal gap, in everyday dentistry, it is acceptable to use all three self-adhesive resin cements, although the G-cem ONE group exhibited the lowest marginal gap for ZLS single crowns.

6.
Cureus ; 16(6): e61903, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38855484

RESUMO

Vertical dimension (VD) is a critical factor in prosthodontics, playing a pivotal role in the functional and aesthetic outcomes of dental treatments. This literature review explores theoretical foundations and the various aspects of VD, including its definition, measurement, and clinical significance in prosthodontics. The relationship between VD and temporomandibular disorders (TMDs) is examined. Additionally, the impact of VD on facial proportions and aesthetics is significant, as it affects the lower third of the face and influences the patient's overall appearance and self-esteem. In conclusion, understanding the intricate relationship between VD, TMDs, facial aesthetics, and psychological well-being is essential for effective prosthodontic treatment. This comprehensive review provides valuable insights into the multifaceted role of VD in enhancing both functional and aesthetic outcomes, ultimately improving patient satisfaction and quality of life.

7.
Clin Cosmet Investig Dent ; 16: 167-177, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38827119

RESUMO

A method is described for designing, fabricating and implementing sequential template immediate loading protocols for dual arch implant therapy. A 41-year-old medically-free patient with terminal dentition was treated following stackable guide loading protocols for maxillary and mandibular arches. Implants were placed following extractions and immediately loaded with full arch fixed prostheses. Healing was uneventful and all implants integrated successfully. Special consideration was given to the design and clinical challenges when implementing stackable guide protocols for dual arch implant therapy.

8.
J Mech Behav Biomed Mater ; 157: 106608, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38833781

RESUMO

This study assessed the monotonic and fatigue flexural strength (FS), elastic modulus (E), and surface characteristics of a 3D printed zirconia-containing resin composite compared to subtractive and conventional layering methods. Specimens, including discs (n = 15; Ø = 15 mm × 1.2 mm) and bars (n = 15; 14 × 4 × 1.2 mm), were prepared and categorized into three groups: 3D printing (3D printing - PriZma 3D Bio Crown, Makertech), Subtractive (Lava Ultimate blocks, 3M), and Layering (Filtek Z350 XT, 3M). Monotonic tests were performed on the discs using a piston-on-three-balls setup, while fatigue tests employed similar parameters with a frequency of 10 Hz, initial stress at 20 MPa, and stress increments every 5000 cycles. The E was determined through three-point-bending test using bars. Surface roughness, fractographic, and topographic analyses were conducted. Statistical analyses included One-way ANOVA for monotonic FS and roughness, Kruskal-Wallis for E, and Kaplan-Meier with post-hoc Mantel-Cox and Weibull analysis for fatigue strength. Results revealed higher monotonic strength in the Subtractive group compared to 3D printing (p = 0.02) and Layering (p = 0.04), while 3D Printing and Layering exhibited similarities (p = 0.88). Fatigue data indicated significant differences across all groups (3D Printing < Layering < Subtractive; p = 0.00 and p = 0.04, respectively). Mechanical reliability was comparable across groups. 3D printing and Subtractive demonstrated similar E, both surpassing Layering. Moreover, 3D printing exhibited higher surface roughness than Subtractive and Layering (p < 0.05). Fractographic analysis indicated that fractures initiated at surface defects located in the area subjected to tensile stress concentration. A porous surface was observed in the 3D Printing group and a more compact surface in Subtractive and Layering methods. This study distinguishes the unique properties of 3D printed resin when compared to conventional layering and subtractive methods for resin-based materials. 3D printed shows comparable monotonic strength to layering but lags behind in fatigue strength, with subtractive resin demonstrating superior performance. Both 3D printed and subtractive exhibit similar elastic moduli, surpassing layering. However, 3D printed resin displays higher surface roughness compared to subtractive and layering methods. The study suggests a need for improvement in the mechanical performance of 3D printed material.

9.
Int J Prosthodont ; 0(0): 1-22, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38848506

RESUMO

OBJECTIVE: To investigate the effect of digital scanning combined with reverse engineering technology in the demonstration of full crown tooth preparation. METHODS: Thirty-one students were randomly divided into the two groups. The students in the control group carried out traditional demonstration by the use of eye-measurement methods. The students in the experimental group carried out improved demonstration by the use of digital intraoral scan with 3D measurement data. The students in both groups were provided with two resin teeth to conduct full crown tooth preparation on head model dental simulators. The teeth prepared before and after demonstration were scored by Chinese Stomatological Association Group Standards, with a total score of 100 points. Analysis of covariance was performed to comparatively analyze the scores related to the tooth surfaces, and convergence angle between two groups. RESULTS: Analysis of two prepared teeth (tooth #11 and #16) in two groups showed that there was a statistical significant difference in the mean score between the control group and experimental group (tooth #11, P = 0.0039) (tooth #16, P = 0.0120).The demonstration of the tooth #16 showed that there were statistical significant differences in the scores related to buccolingual surface (P = 0.0205) and proximal surface (P = 0.0023) between the control group and experimental group; There was a statistical significant difference in the score related to the convergence angle of buccolingual surface between the control group and experimental group (P = 0.0265). CONCLUSION: The digital methods can effectively improve the quality of tooth preparations and has a pedagogical advantage for posterior teeth, which present greater operational challenges.

10.
J Esthet Restor Dent ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38923782

RESUMO

INTRODUCTION: Erbium-doped yttrium-aluminum-garnet (Er:YAG) laser debonding of zirconia and lithium disilicate restorations is increasingly used for a range of clinical applications. Using rotary instruments to remove such restorations for any purpose has proven to be challenging. Erbium laser has been reported to be a conservative method for removing ceramic restorations. There is little data in the literature about the effect of adhesive resin cement type on the debonding time of the ceramic restoration using the Er:YAG laser. OBJECTIVES: To evaluate and compare the time required for the Er:YAG laser to debond zirconia and lithium disilicate crowns bonded with a 2- and 1-bottle adhesive resin cement systems. MATERIALS AND METHODS: Forty extracted premolar teeth were prepared and scanned for milled 40 CAD/CAM crowns. Teeth were randomly assigned into groups (n = 10 per group): 3 mol% yttria-partially stabilized zirconia crowns 3Y-PSZ (G1a) bonded with Panavia™ V5 (2-bottle adhesive resin cement), Zirconia 3Y-PSZ crowns (G1b) bonded with RelyX™ Ultimate (1-bottle adhesive resin cement), and for the lithium disilicate crowns bonded with the two types of cements (G2a, G2b). Each specimen was irradiated with an Er:YAG laser at 335 mJ, 15 Hz, 5.0 W, and 50-ms pulse duration (super short pulse mode). The irradiation time required for crowns to be successfully debonded was recorded for each specimen. Data were statistically analyzed using ANOVA and Tukey HSD post-hoc test (p < 0.05), at the 95 percent level of confidence. The intaglio surface of the debonded crown was analyzed using scanning electron microscopy (SEM). RESULTS: The mean ± standard deviation times needed for crown debonding were 5.75 ± 2.00 min for the G1a group, 4.79 ± 1.20 min for group G1b, 1.69 ± 0.49 min for group G2a, and 1.12 ± 0.17 for group G2b. There was no statistically significant difference in debonding time between the 2- and 1- bottle adhesive resin cement within the groups G1a and b (p = 0.2914), or between groups G2a b (p = 0.7116). A statistically significant difference (p < 0.05) was found between groups G1a and G2a and b and between groups G1b and G2a and b were SEM analysis showed no changes in the microstructure of the ceramic surface after Er:YAG laser irradiation. CONCLUSION: Zirconia and lithium disilicate restorations can be debonded using Er:YAG lasers in a safe and efficient manner. There is no significant difference in the debonding time between the 2- and 1- bottle adhesive resin cement systems used in this study. CLINICAL SIGNIFICANCE: Retrieving zirconia and lithium disilicate ceramics can be a challenging process when using diamond rotary instruments. ER:YAG lasers may efficiently debond these ceramics from the tooth structure, independent of the bonding process used for bonding them.

11.
Heliyon ; 10(11): e31069, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38841506

RESUMO

Purpose: The purpose of this study was to examine the level of evidence (LOE) characteristics and associated factors that change over time in three leading prosthodontics journals. Materials and methods: Articles published in The Journal of Prosthetic Dentistry (JPD), International Journal of Prosthodontics (IJP), and Journal of Prosthodontics (JP) in 2013 and 2020 were reviewed by eight independent reviewers. After applying exclusion and inclusion criteria, the number of authors, the corresponding author's educational degree, corresponding author's origin in each clinical research article were recorded. The included articles were rated by reviewers according to the level of evidence criteria and proposed level of evidence-associated factors. Descriptive statistics, univariable, and binary logistic regression analysis were performed to investigate dependent variables and potentially associated factors. All independent variables with a significant effect were analyzed by using a multivariable test. The entry and exit alpha level were set at αE = 0.15. The statistical significance was set at α = 0.05. Results: A total of 439 articles from 3 selected journals for the years studied met the inclusion criteria. The percentages of level 1, 2, 3, 4, and 5 articles were 2.7 %, 11.4 %, 9.6 %, 13.4 % and 62.9 %, respectively. Univariable analysis results demonstrated significant associations related to the number of authors (P = 0.005), the corresponding author's educational degree (P = 0.022), and the corresponding author's geographic origin (P = 0.042). Multivariable analysis results demonstrated significant associations related to the number of authors (P = 0.002), and the corresponding author's geographic origin (P = 0.014). Conclusions: The number of authors, CA degree, and CA origin had a significant association with the LOE of included prosthodontic studies. Although there was an increase in the number of publications from 2013 to 2020, the level of evidence trend shows no improvement over the years.

12.
Artigo em Inglês | MEDLINE | ID: mdl-38863078

RESUMO

INTRODUCTION: To present the 3-year clinical, radiographic, and aesthetic outcomes in patients with congenitally missing lateral incisors rehabilitated with two narrow-diameter implants (NDIs). METHODS: The original population consisted of 100 patients rehabilitated with a cement-retained bi-layered zirconia single-unit crown supported by either a Ø2.9 mm (Test) or a Ø3.3 mm (Control) NDI (n = 50). At the 1- and 3-year follow-up (T2, T3), implant survival rate, crestal bone level (CBL) changes, biological, and technical complications were recorded, while the assessment of the aesthetic outcomes was performed using the Copenhagen Index Score. RESULTS: Seventy-four patients Ø2.9 mm (n = 39) or Ø3.3 mm (n = 35) reached T3, as 24 patients were lost to follow-up and 1 implant (Ø3.3 mm) was removed. Throughout the observation period, minimal CBL changes (i.e., <1 mm) were detected between groups. Despite the positive aesthetic scores recorded (i.e., 1-2), at T3 20% of patients rehabilitated with a Ø3.3 mm versus 2.6% of patients Ø2.9 mm displayed an alveolar process deficiency (Score 3). No additional technical and/or mechanical complications were recorded between T2 and T3. Tooth vitality was maintained in all neighboring teeth. Peri-implant probing depths and plaque scores remained low in both groups (p > 0.05). CONCLUSION: The use of 2.9 or 3.3 diameter implants showed comparable favorable mid-term results in terms of survival rate, CBL, and aesthetic outcomes. Hence, clinicians should rely on the use of such NDIs when replacing maxillary lateral incisors.

13.
J Dent ; 148: 105217, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38944264

RESUMO

OBJECTIVES: Tooth preparation is complicated because it requires the preparation of an abutment while simultaneously predicting the ideal shape of the tooth. This study aimed to develop and evaluate a system using augmented reality (AR) head-mounted displays (HMDs) that provide dynamic navigation capabilities for tooth preparation. METHODS: The proposed system utilizes optical see-through HMDs to overlay digital information onto the real world and enrich the user's environment. By integrating tracking algorithms and three-dimensional modeling, the system provides real-time visualization and navigation capabilities during tooth preparation by using two different visualization techniques. The experimental setup involved a comprehensive analysis of the distance to the surface and cross-sectional angles between the ideal and prepared teeth using three scenarios: traditional (without AR), overlay (AR-assisted visualization of the ideal prepared tooth), and cross-sectional (AR-assisted visualization with cross-sectional views and angular displays). RESULTS: A user study (N = 24) revealed that the cross-sectional approach was more effective for angle adjustment and reduced the occurrence of over-reduction. Additional questionnaires revealed that the AR-assisted approaches were perceived as less difficult, with the cross-sectional approach excelling in terms of performance. CONCLUSIONS: Visualization and navigation using cross-sectional approaches have the potential to support safer tooth preparation with less overreduction than traditional and overlay approaches do. The angular displays provided by the cross-sectional approach are considered helpful for tooth preparation. CLINICAL SIGNIFICANCE: The AR navigation system can assist dentists during tooth preparation and has the potential to enhance the accuracy and safety of prosthodontic treatment.

14.
Swiss Dent J ; 134(1): 72-83, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38716799

RESUMO

Bonded indirect restorations can be difficult to lute in an accurate position due to the lack of preparation geometry. Furthermore, while the use of a rubberdam has been proven to be the best technique for providing the most efficient conditions for adhesive luting, its use often requires the use of secondary clamps, which do not allow the operator to lute more than two prosthetic pieces at the same time. The multi-luting concept is a pragmatic approach that of- fers the possibility to deliver several, if not all restorations, to be bonded at the same time, thus ensuring their correct positioning.


Assuntos
Colagem Dentária , Humanos , Colagem Dentária/métodos , Cimentos de Resina , Cimentos Dentários
15.
Swiss Dent J ; 134(2): 53-71, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38739770

RESUMO

Oral healthcare among the frail is an underestimated geriatric care element. While neglected oral health (OH) is a well-established risk factor for frailty, frailty can be a risk factor for subsequent OH problems. The cross-sectional investigation nested into the SAPALDIA sub-cohort of citizens aged 52 years and older, aims to stimulate longitudinal research into aspects that accelerate poor OH among frail individuals. The hypothesis investigated was that (pre-) frail individuals are more likely to have missing teeth replaced with removable dental prostheses (RDP) resulting in difficulties with chewing. The study included 1489 participants undergoing geriatric assessments and oral examination. The main predictor was frailty status (non-frail; pre-frail; frail), based on Fried's frailty phenotype. The main outcomes of interest were non-functional dentition (presence of ≤ 19 natural teeth), presence of any RDP and self-reported difficulties with chewing. Pre-frailty and frailty were not associated with the presence of ≤ 19 natural teeth, but were associated with a higher RDP prevalence. The presence of at least one complete denture (CD) had 1.71 fold and 2.54 folds higher odds among pre-frail and frail, respectively, compared to non-frail individuals. Frail individuals with CD reported chewing difficulties 7.8 times more often than non-frail individuals without CD. The results are in line with the hypothesis that (pre-) frail individuals may be more likely to have tooth loss restored by RDPs. Future longitudinal research needs to assess potential barriers to oral hygiene and fixed dental prostheses among (pre-) frail and to study their oral health-related quality of life.


Assuntos
Idoso Fragilizado , Mastigação , Humanos , Idoso , Feminino , Masculino , Mastigação/fisiologia , Pessoa de Meia-Idade , Estudos Transversais , Suíça/epidemiologia , Estudos de Coortes , Idoso de 80 Anos ou mais , Avaliação Geriátrica , Saúde Bucal/estatística & dados numéricos , Fragilidade/epidemiologia , Prótese Parcial Removível , Prótese Total/efeitos adversos
16.
Int J Esthet Dent ; 19(2): 140-150, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726856

RESUMO

The present technical article describes a protocol to digitally reproduce the emergence profile of an interim implant prosthesis (IP) and to transfer its macrogeometry into the definitive restoration. The purpose of this protocol was to minimize alterations in the gingival architecture developed during the interim restorative phase of a single implant that could potentially jeopardize its esthetic outcome. The process included obtaining an intraoral scan with the interim IP in situ, a duplicate of this intraoral scan that was used to capture the exact position of the implant, and an extraoral scan of the prosthesis. These data could then be imported into IOS software to create a model where the patients' soft tissue was incorporated with precision, allowing for the fabrication of a definitive crown with an optimal soft tissue adaptation. As there are few articles in the scientific literature that have reported a consistent method to replicate the emergence profile of an interim IP, the present technical article aims to highlight the potential of utilizing the emergence profile of an interim IP created by IOS software.


Assuntos
Software , Humanos , Estética Dentária , Desenho Assistido por Computador , Coroas , Prótese Dentária Fixada por Implante/métodos , Restauração Dentária Temporária/métodos , Planejamento de Prótese Dentária/métodos , Implantes Dentários para Um Único Dente
17.
J Esthet Restor Dent ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38757761

RESUMO

OBJECTIVES: To provide an overview of the current artificial intelligence (AI) based applications for assisting digital data acquisition and implant planning procedures. OVERVIEW: A review of the main AI-based applications integrated into digital data acquisitions technologies (facial scanners (FS), intraoral scanners (IOSs), cone beam computed tomography (CBCT) devices, and jaw trackers) and computer-aided static implant planning programs are provided. CONCLUSIONS: The main AI-based application integrated in some FS's programs involves the automatic alignment of facial and intraoral scans for virtual patient integration. The AI-based applications integrated into IOSs programs include scan cleaning, assist scanning, and automatic alignment between the implant scan body with its corresponding CAD object while scanning. The more frequently AI-based applications integrated into the programs of CBCT units involve positioning assistant, noise and artifacts reduction, structures identification and segmentation, airway analysis, and alignment of facial, intraoral, and CBCT scans. Some computer-aided static implant planning programs include patient's digital files, identification, labeling, and segmentation of anatomical structures, mandibular nerve tracing, automatic implant placement, and surgical implant guide design.

18.
J Dent Educ ; 88 Suppl 1: 713-726, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38758043

RESUMO

OBJECTIVES: Dental residents experience high stress in their demanding programs and gender-based harassment/discrimination can contribute to their stress. The objectives were to compare stress, satisfaction, experienced sexual harassment and observed discrimination of women in dental graduate programs with high, medium, and low percentages of women and to explore relationships between these constructs of interest. METHODS: Note that, 112 pediatric dentistry (PD), 44 prosthodontics, and 56 oral and maxillofacial surgery (OMS) residents responded to a survey. RESULTS: PD residents had the lowest personal life-related stress (4-point scale with 4 = very stressful: PD = 2.99/P = 3.67/OMS = 3.56; p < 0.001), faculty-related stress (2.68/3.66/3.03; p < 0.001), lack of confidence-related stress (2.79/3.31/2.96; p < 0.01) and academic stress (2.65/3.24/3.02; p < 0.001), while prosthodontics residents had the highest stress levels. The average frequency of experiencing sexual harassment was highest for OMS residents and lowest for PD residents (5-point scale with 1 = never: 1.15/2.62/2.74; p < 0.001). PD residents observed least and OMS residents most frequently that female residents were treated less positively by other residents because of their gender (1.59/2.57/3.00; p < 0.001). Prosthodontics residents had the lowest job satisfaction score (5-point scale with 1 = lowest satisfaction: 4.12/3.14/4.20; p < 0.001). The more frequently male and female residents experienced sexual harassment, the higher their personal life-related stress, faculty-related stress, lack of confidence-related stress, and academic stress, and the lower their career satisfaction, specialty content satisfaction, and stress-related satisfaction. Women's frequencies of observed gender-based discrimination were associated with higher stress and lower satisfaction, while men's frequencies of these observations were not associated with stress, but associated with increased satisfaction. CONCLUSIONS: Dental residents' stress, career satisfaction, experienced sexual harassment, and observed discrimination of women residents differ depending on the dental specialty program. Both male and female residents report more stress and less satisfaction the more they experience sexual harassment. The more women observe discrimination of women, the more stressed and the less satisfied they are. For men, the frequencies of these observations are not associated with stress, but positively associated with increased satisfaction.


Assuntos
Internato e Residência , Satisfação no Emprego , Odontopediatria , Prostodontia , Sexismo , Cirurgia Bucal , Humanos , Feminino , Masculino , Sexismo/psicologia , Cirurgia Bucal/educação , Odontopediatria/educação , Prostodontia/educação , Assédio Sexual/psicologia , Assédio Sexual/estatística & dados numéricos , Estresse Psicológico , Adulto , Inquéritos e Questionários
19.
Cureus ; 16(4): e58346, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38756310

RESUMO

Surgery for palate lesions may result in oro-nasal/antral communication, which reduces a person's quality of life by affecting swallowing, speech, and food reflux. The shape and size of this obturator prosthesis might vary based on the severity of the defect. This case report describes the prosthetic rehabilitation of the patient with post-COVID mucormycosis and generalized attrition of teeth using an obturator and full mouth rehabilitation.

20.
Materials (Basel) ; 17(9)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38730936

RESUMO

The marginal accuracy of fit between prosthetic restorations and abutment teeth represents an essential aspect with regard to long-term clinical success. Since the final gap is also influenced by the luting techniques and materials applied, this study analyzed the accuracy of the fit of single-tooth zirconia copings before and after cementation using different luting materials. Forty plaster dies with a corresponding zirconia coping were manufactured based on a single tooth chamfer preparation. The copings were luted on the plaster dies (n = 10 per luting material) with a zinc phosphate (A), glass-ionomer (B), self-adhesive resin (C), or resin-modified glass-ionomer cement (D). The accuracy of fit for each coping was assessed using a non-destructive digital method. Intragroup statistical analysis was conducted using Wilcoxon signed rank tests and intergroup analysis by Kruskal-Wallis and Mann-Whitney U tests (α = 0.05). Accuracy of fit was significantly different before/after cementation within A (0.033/0.110 µm) and B (0.035/0.118 µm; p = 0.002). A had a significantly increased marginal gap compared to C and D, and B compared to C and D (p ≤ 0.001). Significantly increased vertical discrepancies between A and B versus C and D (p < 0.001) were assessed. Of the materials under investigation, the zinc phosphate cement led to increased vertical marginal discrepancies, whereas the self-adhesive resin cement did not influence the restoration fit.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...