Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
1.
JTCVS Open ; 19: 9-30, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39015444

RESUMO

Background: There is no consensus regarding the strategies for repairing acute type A aortic dissection (ATAAD) in patients with bicuspid aortic valve (BAV). This meta-analysis aimed to compare the treatment strategies and outcomes of ATAAD repair between patients with BAV and those with tricuspid aortic valve (TAV). Methods: A systematic review of databases were performed from inception through March 2023. The primary outcome of interest was all-cause mortality, with a minimum follow-up of 1 year. The secondary outcomes of interest included ratios of performed procedures and rate of distal aortic reoperation. Data were extracted, and pooled analysis was performed using a random-effects model. Results: Eight observational studies including a total of 3701 patients (BAV, n = 349; TAV, n = 3352) were selected for a meta-analysis. Concerning proximal aortic procedures, BAV patients exhibited a higher incidence of necessary root replacement (odds ratio [OR], 6.53; 95% confidence interval [CI], 3.84 to 11.09; P < .01). Regarding distal aortic procedures, extended arch replacement was performed less frequently in BAV patients (OR, 0.69; 95% CI, 0.49 to 0.99; P = .04), whereas hemiarch procedure rates were comparable in the 2 groups. All-cause mortality was lower in the BAV group (hazard ratio, 0.68; 95% CI, 0.50 to 0.92; P = .01). Distal aortic reoperation rates were comparable in the 2 groups. Conclusions: This study highlights distinct procedural patterns in ATAAD patients with BAV and TAV. Despite differing baseline characteristics, BAV patients exhibited superior survival compared to TAV patients, with comparable distal aortic reoperation rates. These findings may be useful for decision making regarding limited versus extended aortic arch repair.

2.
Braz J Cardiovasc Surg ; 39(4): e20230438, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39038201

RESUMO

OBJECTIVES: The aims of the present study were to compare the long-term outcomes for ascending aortic dilatation and adverse aortic events after isolated aortic valve replacement between patients with bicuspid aortic valve (BAV) and tricuspid aortic valve ( TAV). METHODS: This retrospective study included 310 patients who had undergone isolated aortic valve replacement with an ascending aorta diameter ≤ 45 mm between January 2010 and September 2021. The patients were divided into BAV group (n=90) and TAV group (n=220). The differences in the dilation rate of the ascending aorta and long-term outcomes were analyzed. RESULTS: Overall survival was 89 ± 4% in the BAV group vs. 75 ± 6% in the TAV group at 10 years postoperatively (P=0.007), yet this difference disappeared after adjusting exclusively for age (P=0.343). The mean annual growth rate of the ascending aorta was similar between the two groups during follow-up (0.5 ± 0.6 mm/year vs. 0.4 ± 0.5 mm/year; P=0.498). Ten-year freedom from adverse aortic events was 98.1% in the BAV group vs. 95.0% in the TAV group (P=0.636). Multivariable analysis revealed preoperative ascending aorta diameter to be a significant predictor of adverse aortic events (hazard ratio: 1.76; 95% confidence interval: 1.33 to 2.38; P<0.001). CONCLUSION: Our study revealed that the long-term survival and the risks of adverse aortic events between BAV and TAV patients were similar after isolated aortic valve replacement. BAV was not a risk factor of adverse aortic events.


Assuntos
Aorta , Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Feminino , Estudos Retrospectivos , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/complicações , Pessoa de Meia-Idade , Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Idoso , Implante de Prótese de Valva Cardíaca/mortalidade , Aorta/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/mortalidade , Valva Tricúspide/cirurgia , Progressão da Doença , Fatores de Risco , Resultado do Tratamento , Complicações Pós-Operatórias
3.
J Clin Med ; 13(14)2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39064264

RESUMO

Background: This research explores the biomechanical and structural characteristics of ascending thoracic aortic aneurysms (ATAAs), focusing on the differences between bicuspid aortic valve aneurysms (BAV-As) and tricuspid aortic valve aneurysms (TAV-As) with non-dilated aortas to identify specific traits of ATAAs. Methods: Clinical characteristics, laboratory indices, and imaging data from 26 adult patients operated on for aneurysms (BAV-A: n = 12; TAV-A: n = 14) and 13 controls were analyzed. Biomechanical parameters (maximal aortic diameter, strain, and stress) and structural analyses (collagen fiber organization, density, fragmentation, adipocyte deposits, and immune cell infiltration) were assessed. Results: Significant differences in biomechanical parameters were observed. Median maximal strain was 40.0% (control), 63.4% (BAV-A), and 45.3% (TAV-A); median maximal stress was 0.59 MPa (control), 0.78 MPa (BAV-A), and 0.48 MPa (TAV-A). BAV-A showed higher tangential modulus and smaller diameter, with substantial collagen fragmentation (p < 0.001 vs. TAV and controls). TAV-A exhibited increased collagen density (p = 0.025), thickening between media and adventitia layers, and disorganized fibers (p = 0.036). BAV-A patients had elevated adipocyte deposits and immune cell infiltration. Conclusions: This study highlights distinct pathological profiles associated with different valve anatomies. BAV-A is characterized by smaller diameters, higher biomechanical stress, and significant collagen deterioration, underscoring the necessity for tailored clinical strategies for effective management of thoracic aortic aneurysm.

4.
Eur Heart J ; 45(37): 3804-3814, 2024 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-38747246

RESUMO

BACKGROUND AND AIMS: Transcatheter aortic valve implantation (TAVI) has become the first choice to treat older patients with severe symptomatic aortic stenosis (AS). This study aimed to compare TAVI with surgery in low-risk patients ≤75 years of age, including both tricuspid and bicuspid AS. METHODS: The Nordic Aortic Valve Intervention (NOTION)-2 trial enrolled and 1:1 randomized low-risk patients aged ≤75 years with severe symptomatic AS to TAVI or surgery. The primary endpoint was a composite of all-cause mortality, stroke, or rehospitalization (related to the procedure, valve, or heart failure) at 12 months. RESULTS: A total of 370 patients were enrolled with a mean age of 71.1 years and a median Society of Thoracic Surgeons risk score of 1.1%. A total of 100 patients had bicuspid AS. The 1-year incidence of the primary endpoint was 10.2% in the TAVI group and 7.1% in the surgery group [absolute risk difference 3.1%; 95% confidence interval (CI), -2.7% to 8.8%; hazard ratio (HR) 1.4; 95% CI, 0.7-2.9; P = .3]. Patients with TAVI, when compared to surgery, had lower risk of major bleeding and new-onset atrial fibrillation and higher risk of non-disabling stroke, permanent pacemaker implantation, and moderate or greater paravalvular regurgitation. The risk of the primary composite endpoint was 8.7% and 8.3% in patients with tricuspid AS (HR 1.0; 95% CI, 0.5-2.3) and 14.3% and 3.9% in patients with bicuspid AS (HR 3.8; 95% CI, 0.8-18.5) treated with TAVI or surgery, respectively (P for interaction = .1). CONCLUSIONS: Among low-risk patients aged ≤75 years with severe symptomatic AS, the rate of the composite of death, stroke, or rehospitalization at 1 year was similar between TAVI and surgery. Transcatheter aortic valve implantation outcomes in young bicuspid AS patients warrant caution and should be further investigated. (NOTION-2, ClinicalTrials.gov, NCT02825134). TRIAL REGISTRATION NUMBER: ClinicalTrials.gov NCT02825134.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Masculino , Feminino , Idoso , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/complicações , Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/complicações , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Readmissão do Paciente/estatística & dados numéricos , Valva Tricúspide/cirurgia
5.
Artigo em Inglês | MEDLINE | ID: mdl-38704861

RESUMO

OBJECTIVES: The objective of this study was primarily to compare four-dimensional flow magnetic resonance imaging metrics in the ascending aorta (AA) of patients with right-left fusion type bicuspid aortic valve (RL-BAV) and repaired coarctation of the aorta (CoA) to RL-BAV without CoA. Metrics of patients with RL-BAV were also compared to the matched group of patients with common tricuspid aortic valve (TAV). METHODS: Eleven patients with RL-BAV and CoA, 11 patients with RL-BAV without CoA and 22 controls with TAV were investigated. Peak velocity (cm/s), peak flow (ml/s) and flow displacement (%) were analysed at 5 pre-defined AA levels. In addition, regional wall shear stress (WSS, mN/m2), circumferential WSS (WSSc) and axial WSS (WSSa) at all levels were quantified in 6 sectors of the aortic circle. Averaged WSS values on each level (WSSavg, WSSc, avg and WSSa, avg) were calculated as well. RESULTS: Peak velocity at the proximal tubular AA was significantly lower in BAV and CoA group (P = 0.047) compared to BAV without CoA. In addition, the WSSa, avg was found to be higher for the BAV and CoA group at proximal AA respectively (P = 0.040). No other significant differences were found between these groups. BAV group's peak velocity was higher at every level (P < 0.001-0.004) compared to TAV group. Flow displacement was significantly higher for the BAV group at every level (P < 0.001) besides at the most distal level. All averaged WSS values were significantly higher in BAV patients in distal AA (P < 0.001-0.018). CONCLUSIONS: Repaired CoA does not relevantly alter four-dimensional flow metrics in the AA of patients with RL-BAV. However, RL-BAV majorly alters flow dynamics in the AA when compared to patients with TAV. CLINICAL TRIAL REGISTRATION NUMBER: https://www.clinicaltrials.gov/study/NCT05065996, Unique Protocol ID 5063566.

7.
J Am Heart Assoc ; 13(9): e032532, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38686861

RESUMO

BACKGROUND: This study was performed to determine cusp causes of aortic regurgitation in patients with tricuspid aortic valves without significant aortic dilatation and define cusp pathologies amenable to surgical repair (aortic valve repair [AVr]) versus aortic valve replacement. METHODS AND RESULTS: We retrospectively reviewed surgical reports of consecutive adults with tricuspid aortic valves undergoing surgery for clinically significant aortic regurgitation within a prospective registry from January 2005 to September 2019. Valvular mechanisms were determined by systematic in vivo intraoperative quantification methods. Of 516 patients, 287 (56%) underwent repair (AVr; mean±SD age, 59.9±12.4 years; 81% men) and 229 (44%) underwent replacement (aortic valve replacement; mean±SD age, 62.8±13.8 years [P=0.01 compared to AVr]; 67% men). A single valvular mechanism was present in 454 patients (88%), with cusp prolapse (46%), retraction (24%), and perforation (18%) being the most common. Prolapse involved the right cusp in 86% of cases and was more frequent in men (P<0.001). Two-dimensional transesophageal echocardiography accuracy for predicting mechanisms was 73% to 82% for the right cusp, 55% to 61% for the noncoronary cusp, and 0% for the left-coronary cusp. Cusp prolapse, younger age, and larger patient size were associated with successful AVr (all P<0.03), whereas retraction, perforation, older age, and concomitant mitral repair were associated with aortic valve replacement (all P<0.03). CONCLUSIONS: Right cusp prolapse is the most frequent single valvular mechanism in patients with tricuspid aortic valve aortic regurgitation, followed by cusp retraction and perforation. The accuracy of 2-dimensional transesophageal echocardiography is limited for left and noncoronary cusp mechanistic assessment. Prolapse is associated with successful AVr, whereas retraction and perforation are associated with aortic valve replacement. With systematic intraoperative quantification methods and current surgical techniques, more than half of tricuspid aortic valve aortic regurgitation cases may be successfully repaired.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Idoso , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Resultado do Tratamento , Sistema de Registros , Anuloplastia da Valva Cardíaca/métodos
8.
J Thorac Dis ; 16(1): 593-603, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38410558

RESUMO

Background: Due to the influence of anatomical structure, replacing the bicuspid valve using transcatheter aortic valve replacement (TAVR) would increase the risk of perivalvular leakage and conduction block, affecting the hemodynamic effect of the interventional valve. In this study, for bicuspid and tricuspid valves, we implemented different valve selection strategies to explore the safety and effectiveness of TAVR in the treatment of bicuspid aortic stenosis with "down-size" interventional valves using the VenusA-valve system. Methods: The operation was performed with the VenusA-valve via transfemoral approach. The selected valves were appropriately sized based on the results of transthoracic echocardiography (TTE), contrast-enhanced computed tomography (CT), and the morphology of intraoperative pre-dilation balloons. For tricuspid valve cases, the VenusA valve is usually larger than the annulus diameter, whereas the "down-size" approach was adopted for bicuspid aortic valve (BAV) cases. The shape of the pre-dilation balloon allowed further sizing of the annulus diameter by the degree of lumbar constriction of the balloon, aiding in intervention valve size selection, particularly in cases of BAVs. Results: A total of 65 patients underwent TAVR for aortic stenosis with VenusA-valve systems. Of these, 29 cases had a BAV and 36 cases had a tricuspid aortic valve (TAV). The distribution of VenusA-valve sizes differed between TAV and BAV cases (P=0.007). Furthermore, there was a significant decrease in the average mean gradient in TAV patients from 54.7 to 12.2 mmHg (P<0.001), and in BAV patients from 61.6 to 14.3 mmHg (P<0.001). The percentage of paravalvular leakage greater than mild was 6.90% in the BAVs and 5.56% in the TAVs at procedural outcomes (P=0.955). The mean follow-up period was 22.23 months (range, 12 to 39 months). The proportion of New York Heart Association (NYHA) class III/IV decreased from 78.5% preoperatively to 11.3% at the last follow-up (P<0.001). A total of 27 patients with TAV and 19 patients with BAV underwent TTE at 1-year follow-up after operation. There was no significant contrast in the average pressure difference between TAVs and BAVs at 1-year follow-up (11.9 vs. 14.3 mmHg, P=0.18). Conclusions: The VenusA-valve for TAVR produced positive clinical outcomes and valve functionality in both BAVs and TAVs. In the case of BAVs, selecting a smaller interventional valve size was deemed viable.

9.
Artigo em Inglês | MEDLINE | ID: mdl-38419579

RESUMO

OBJECTIVES: In patients with aortic root aneurysm, the aortic basal ring is frequently dilated. It has been speculated that the muscular part of the basal ring dilates most. The purpose of this study was to analyse the segmental dilatation of the basal ring, comparing normal and dilated roots in patients with tricuspid aortic valves. METHODS: Retrospective analysis of computed tomography studies in patients with normal and dilated aortic roots was performed. Lengths of segments of the basal ring corresponding to each of the 3 sinuses, and to the muscular and fibrous parts were measured. Fractions of these segments relative to the total basal ring perimeter were calculated. RESULTS: We analysed 152 normal and 126 dilated aortic roots and 86 propensity-matched pairs. Basal ring dilatation was present in all segments of dilated aortic roots with subtle differences between the segments corresponding to the 3 sinuses. The muscular part of the basal ring dilated proportionately to its fibrous part, with no difference in fractions of measured muscular part in normal and dilated roots [42.2% (interquartile range 4.3%) vs 42.1% (interquartile range 6.3%)]. CONCLUSIONS: Basal ring dilatation was present in all segments corresponding to the 3 sinuses in dilated aortic roots. Both muscular and fibrous parts dilated equally, supporting the need to stabilize the entire basal ring when performing aortic valve repair surgery.

11.
J Cardiovasc Dev Dis ; 11(1)2024 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-38248887

RESUMO

Surgical repair for regurgitant bicuspid aortic valve (BAV) is promising but underutilized due to perceived complexities and lack of long-term data. This study evaluated the efficacy of valve-sparing root remodeling (VSRR) or isolated valve repair combined with calibrated external ring annuloplasty in BAV versus tricuspid aortic valve (TAV) patients. All patients operated on for aortic regurgitation and/or aneurysm at our institution between 2014 and 2022 were included and entered into the Aortic Valve Insufficiency and ascending aorta Aneurysm InternATiOnal Registry (AVIATOR). Patients with successful repair at index surgery (100% in the BAV group, 93% in the TAV group, p = 0.044) were included in a systemic follow-up with echocardiography at regular intervals. Among 132 patients, 58 were in the BAV (44%) and 74 in the TAV group (56%). There were no inter-group differences in preoperative patient characteristics, except BAV patients being significantly younger (47 ± 18 y vs. 60 ± 14 y, p < 0.001) and having narrower aortic roots at the level of sinuses (41 ± 6 mm vs. 46 ± 13 mm, p < 0.001) and sinotubular junctions (39 ± 10 mm vs. 42 ± 11, p = 0.032). No perioperative deaths were recorded. At four years, there was no significant difference in terms of overall survival (96.3% BAV vs. 97.2% TAV, p = 0.373), freedom from valve reintervention (85.2% BAV vs. 93.4% TAV, p = 0.905), and freedom from severe aortic regurgitation (94.1% BAV vs. 82.9% TAV, p = 0.222). Surgical repair of BAV combined with extra-aortic annuloplasty can be performed with low perioperative morbidity and mortality and excellent mid-term results which are comparable to TAV repair.

12.
Gen Thorac Cardiovasc Surg ; 72(5): 305-310, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37656401

RESUMO

OBJECTIVE: Aortic dilatation concurrent with aortic valve disease is a common condition. However, the incidence of aortic dissection after aortic valve replacement for tricuspid aortic valve has not been fully investigated. Therefore, we performed a risk factor analysis for the incidence of aortic dissection after aortic valve replacement in patients with tricuspid aortic valve. METHODS: We retrospectively reviewed 599 patients who underwent aortic valve replacement at our hospital between January 2000 and December 2020. We performed a risk factor analysis for the incidence of aortic dissection after aortic valve replacement in patients with tricuspid aortic valve. RESULTS: Seven patients developed late aortic dissections during the follow-up period. All patients with aortic dissection underwent aortic valve replacement for aortic regurgitation. Multivariable analysis revealed that aortic regurgitation was an independent predictor of aortic dissection (p < 0.0001). The mean ascending aortic diameter at aortic valve replacement for aortic regurgitation was significantly greater in patients with aortic dissection than in those without aortic dissection (46 [43.5-46] mm vs. 39 [36-42] mm, p < 0.001). The predictive cutoff value of ascending aortic diameter was indicated using receiver operating characteristic curve analysis; 46.0 mm (area under the curve: 0.8987). Freedom rates from aortic dissection in patients with aortic regurgitation and an ascending aortic diameter ≥ 46 mm were significantly lower than those in patients with an ascending aortic diameter < 46 mm (66.7% vs. 100% at 5 years, p < 0.0001). CONCLUSION: Aortic regurgitation combined with ascending aortic dilatation at aortic valve replacement could be a significant risk factor for late aortic dissection.


Assuntos
Aneurisma Aórtico , Doenças da Aorta , Dissecção Aórtica , Insuficiência da Valva Aórtica , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estudos Retrospectivos , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/etiologia , Aneurisma Aórtico/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Fatores de Risco
13.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;39(4): e20230438, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1569617

RESUMO

ABSTRACT Objectives: The aims of the present study were to compare the long-term outcomes for ascending aortic dilatation and adverse aortic events after isolated aortic valve replacement between patients with bicuspid aortic valve (BAV) and tricuspid aortic valve ( TAV). Methods: This retrospective study included 310 patients who had undergone isolated aortic valve replacement with an ascending aorta diameter ≤ 45 mm between January 2010 and September 2021. The patients were divided into BAV group (n=90) and TAV group (n=220). The differences in the dilation rate of the ascending aorta and long-term outcomes were analyzed. Results: Overall survival was 89 ± 4% in the BAV group vs. 75 ± 6% in the TAV group at 10 years postoperatively (P=0.007), yet this difference disappeared after adjusting exclusively for age (P=0.343). The mean annual growth rate of the ascending aorta was similar between the two groups during follow-up (0.5 ± 0.6 mm/year vs. 0.4 ± 0.5 mm/year; P=0.498). Ten-year freedom from adverse aortic events was 98.1% in the BAV group vs. 95.0% in the TAV group (P=0.636). Multivariable analysis revealed preoperative ascending aorta diameter to be a significant predictor of adverse aortic events (hazard ratio: 1.76; 95% confidence interval: 1.33 to 2.38; P<0.001). Conclusion: Our study revealed that the long-term survival and the risks of adverse aortic events between BAV and TAV patients were similar after isolated aortic valve replacement. BAV was not a risk factor of adverse aortic events.

14.
Front Cardiovasc Med ; 10: 1304957, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38155986

RESUMO

Introduction: Bicuspid aortic valve (BAV) is the most common congenital heart disease with an increased risk of infective endocarditis (IE). Few data are available on isolated native BAV-IE. The aim of this study was to compare patients with tricuspid aortic valve (TAV) IE and BAV-IE in terms of characteristics, management and prognosis. Material and methods: We included 728 consecutive patients with IE on isolated native aortic valve in 3 centres: Amiens and Marseille Hospitals in France and Salerno Hospital in Italy. We studied in hospital and long-term mortality before and after matching for age, sex and comorbidity index. Median follow-up was 67.2 [IQR: 19-120] months. Results: Of the 728 patients, 123 (16.9%) had BAV. Compared with patients with TAV-IE, patients with BAV-IE were younger, had fewer co-morbidities and were more likely to be male. They presented more major neurological events and perivalvular complications (both p < 0.05). Early surgery (<30 days) was performed in 52% of BAV-IE cases vs. 42.8% for TAV-IE (p = 0.061). The 10-year survival rate was 74 ± 5% in BAV-IE patients compared with 66 ± 2% in TAV-IE patients (p = 0.047). After propensity score matching (for age, gender and comorbidities), there was no difference in mortality between the two groups, with an estimated 10-year survival of 73 ± 5% vs. 76 ± 4% respectively (p = 0.91). Conclusion: BAV is a frequent finding in patients with isolated aortic valve IE and is associated with more perivalvular complications and neurological events. The differences in survival with TAV-IE are probably related to the age and comorbidity differences between these two populations.

15.
Int J Cardiol Heart Vasc ; 49: 101313, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38107428

RESUMO

Objectives: The aim of the present study was to assess the differences between BAV and TAV patients with chronic moderate to severe or severe AS regarding presentation, incidence of TAVR, survival, ascending aorta diameter and dilatation rate before and after TAVR. Methods: The study included 667 consecutive patients with chronic moderate to severe or severe AS from January 2012 and December 2022. Outcomes included all-cause mortality, incidence of TAVR, and ascending aorta diameter and dilatation rate. Results: There were 185 BAV-AS and 482 TAV-AS patients, and BAV-AS patients were younger (67 vs 78 years, P = 0.027). Total follow-up was 4.5 years (IQR: 2.7-8.9 years), 290 patients underwent TAVR, and 165 patients died. The 8-year TAVR incidence was higher in BAV-AS (55% ± 4%) vs TAV-AS (41% ± 5%; P = 0.02). The 8-year survival was higher in BAV-AS (85% ± 6%) vs TAV-AS (71% ± 6%; P < 0.0001) and became insignificant after age adjustment (P = 0.33). The dilatation rate of ascending aorta was significantly faster in BAV-AS patients compared with TAV-AS patients before TAVR. However, the ascending aorta dilatation rate for BAV-AS and TAV-AS patients was not significantly different after TAVR. Conclusions: Compared with TAV-AS, BAV-AS patients were younger and underwent TAVR more frequently, resulting in a considerable survival advantage. After TAVR, ascending aorta dilatation rates were similar in BAV-AS and TAV-AS patients, suggesting an important role of hemodynamics on ascending aorta dilatation in BAV-AS.

16.
J Cardiothorac Surg ; 18(1): 206, 2023 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-37400892

RESUMO

BACKGROUND: Valve-sparing aortic root replacement (VSARR) is a safe and effective surgical procedure to treat aortic root aneurysm. This meta-analysis aimed to investigate how this procedure might differ in patients with bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV). DESIGN: Meta-analysis with meta-regression and systematic review. SETTING: Systematic search in the following databases: PubMed, Cochrane Central Register of Controlled Trials, and Embase. INTERVENTIONS: All observational studies of VSARR in patients with BAV or TAV were included in our study. Studies were included without any restrictions on language or publication date. A trial sequential analysis and a post-hoc meta-regression was performed on the main outcomes. RESULT: Eleven articles met the inclusion criteria. A total of 1138 patients in BAV group, and 2125 patients in TAV group. No significant differences in gender and age were observed between BAV and TAV patients. BAV and TAV patients showed no differences in in-hospital mortality rate [0.00% vs. 1.93%; RR (95% CI) 0.33 (0.09, 1.26), I2 = 0%, P = 0.11] and the rate of in-hospital reoperation [5.64% vs. 5.99%; RR (95% CI) 1.01(0.59, 1.73), I2 = 33%, P = 0.98]. The overall long-term mortality rate of BAV patients was better than that of TAV patients [1.63% vs. 8.15%; RR (95% CI) 0.34 (0.13, 0.86), I2 = 0%, P = 0.02]. During the follow-up observation period, patients in TAV group showed small but no statistic advantage in 3-year, 5-year, and over 10-year incidences of reintervention. Regarding the secondary endpoints, the two groups showed similar aortic cross-clamping time and total cardiopulmonary bypass time. CONCLUSION: The VSARR techniques yielded similar clinical outcomes in both BAV and TAV patients. Although patients with BAV might have a higher incidence of reinterventions after initial VSARR, it is still a safe and effective approach to treat aortic root dilation with or without aortic valve insufficiency. TAV patients showed small but no statistic advantage in long-term (over 10 years) reintervention rate, which means, patients with BAV may face a higher risk of reintervention in the clinic.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/cirurgia , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/cirurgia , Aorta/cirurgia , Valva Tricúspide/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Estudos Observacionais como Assunto
17.
Artigo em Inglês | MEDLINE | ID: mdl-37302467

RESUMO

OBJECTIVE: Cusp prolapse is an important cause of aortic regurgitation (AR) in tricuspid aortic valves (TAVs) and can be caused by myxomatous degeneration or cusp fenestration. Long-term data for prolapse repair in TAVs are scarce. We analyzed the results of aortic valve repair in patients with TAV morphology and AR caused by prolapse and compared the results for cusp fenestration and myxomatous degeneration. METHODS: Between October 2000 and December 2020, 237 patients (221 male; 15-83 years) underwent TAV repair for cusp prolapse. Prolapse was associated with fenestrations in 94 (group I) and myxomatous degeneration in 143 patients (group II). Fenestrations were closed using a pericardial patch (n = 75) or suture (n = 19). In myxomatous degeneration, prolapse was corrected by free margin plication (n = 132) or triangular resection (n = 11). Follow-up was 97% complete (cumulatively 1531, mean 6.5, median 5.8 years). Cardiac comorbidities were present in 111 patients (46.8%), and more frequent in group II (P = .003). RESULTS: Ten-year survival was better in group I (I: 84.5%; II: 72.4%; P = .037), and patients without cardiac comorbidities (89.2% vs 67.0%; P = .002). Ten-year freedom from reoperation (P = .778), moderate or greater AR (P = .070), and valve-related complications (P = .977) were similar in both groups. AR at discharge was the only significant predictor for reoperation (P = .042). The type of annuloplasty did not affect repair durability. CONCLUSIONS: Repair of cusp prolapse in TAVs with preserved root dimensions can be performed with acceptable durability, even in the presence of fenestrations.

18.
Ann Cardiothorac Surg ; 12(3): 179-193, 2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37304696

RESUMO

The aortic valve (AV) is a three-dimensional structure, with leaflets that are suspended within the functional aortic annulus (FAA). These structures (AV and FAA) are therefore intrinsically connected and disease of just one component can independently lead to AV dysfunction. Hence, AV dysfunction can occur in the setting of entirely normal valve leaflets. However, as these structures are functionally inter-connected, disease of one component can lead to abnormalities of the other over time. Thus, AV dysfunction is often multifactorial. Valve-sparing root procedures require an in-depth understanding of these inter-relationships, and herein we are providing a detailed account of some of the most pertinent anatomical relationships.

19.
Front Cardiovasc Med ; 10: 1064255, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37383702

RESUMO

Background: Data on outcomes following transcatheter aortic valve replacement with SAPIEN 3 in China is limited as it was approved by the National Medical Products since 2020. The present study was designed to collect clinical data on the SAPIEN 3 aortic valve in Chinese patients with bicuspid aortic valve and tricuspid aortic valve stenosis. Methods: We analyzed the patient characteristics, procedural features and procedural outcomes of the first 438 patients (223 for bicuspid aortic valve and 215 tricuspid aortic valve) from 21 provinces in 74 sites treated with the SAPIEN 3 valve system for transcatheter aortic valve replacement between September 2020 and May 2022. Results: Procedural mortality was 0.7%. 5 cases during the operation were converted to surgery. Among 438 cases, permanent pacemaker implantation was performed in a total of 12 cases (2.7%). The patient had severe leaflet calcification of the aortic valve, with moderate and severe calcification reaching 39.7% and 35.2% respectively. The size of the implanted valves was predominantly 26 mm and 23 mm, reaching 42.5% and 39.5% respectively. The incidence of moderate or severe perivalvular leak in the postoperative period was 0.5%, with a predominance of 90/10 and 80/20 valve deployment height. There was a significant difference in the deployment height of the valve between bicuspid aortic valve and tricuspid aortic valve, with the bicuspid aortic valve having a more deployment height of 90/10. Annulus size in bicuspid aortic valve group was significantly larger than tricuspid aortic valve group. Valve sizing for oversized, within size, and undersized were different between bicuspid aortic valve and tricuspid aortic valve. Conclusions: Procedural success rates were high, with similar and good results for bicuspid aortic valve and tricuspid aortic valve, low perivalvular leak for both valve types, and low permanent pacemaker implantation rates for both valve types. Annulus size, valve sizing and coronary artery height were significantly different in the BAV and TAV group.

20.
Int J Mol Sci ; 24(10)2023 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-37239988

RESUMO

Thoracic aortic aneurysms (TAA) consist of abnormal dilation or the widening of a portion of the ascending aorta, due to weakness or destructuring of the walls of the vessel and are potentially lethal. The congenital bicuspid aortic valve (BAV) is considered a risk factor for the development of TAA because asymmetric blood flow through the bicuspid aortic valve detrimentally influences the wall of the ascending aorta. NOTCH1 mutations have been associated with non-syndromic TAAs as a consequence of BAV, but little is known regarding its haploinsufficiency and its relationship with connective tissue abnormalities. We report two cases in which there is clear evidence that alterations in the NOTCH1 gene are the cause of TAA in the absence of BAV. On the one hand, we describe a 117 Kb deletion that includes a large part of the NOTCH1 gene and no other coding genes, suggesting that haploinsufficiency can be considered a pathogenic mechanism for this gene associated with TAA. In addition, we describe two brothers who carry two variants, one in the NOTCH1 gene and another in the MIB1 gene, corroborating the involvement of different genes of the Notch pathway in aortic pathology.


Assuntos
Aneurisma da Aorta Torácica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Masculino , Humanos , Valva Aórtica/patologia , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/genética , Doenças das Valvas Cardíacas/metabolismo , Aorta/metabolismo , Aneurisma da Aorta Torácica/metabolismo , Receptor Notch1/genética , Receptor Notch1/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...