Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 605
Filtrar
1.
BMC Ophthalmol ; 24(1): 388, 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39227793

RESUMO

BACKGROUND: Visual quality after corneal refractive surgery is linked to the postoperative effective optical zone (EOZ). This study aims to compare long-term changes in the EOZ following small incision lenticule extraction (SMILE) and femtosecond laser-assisted in-situ keratomileusis (FS-LASIK) for moderate and high myopia. METHODS: This study included 42 patients (72 eyes) who underwent either SMILE (36 eyes) or FS-LASIK (36 eyes). A custom software program based on the tangential curvature difference map of the Pentacam HR (Oculus Optikgeräte GmbH) was used to define the EOZ at 3 and 7 years postoperatively. The EOZ, its chronological changes compared to the programmed optical zone (POZ), and the corneal wavefront aberrations following SMILE and FS-LASIK were analyzed. Correlations between the EOZ changes and relevant parameters were evaluated. RESULTS: Three years postoperatively, EOZ following SMILE and FS-LASIK were 5.13 ± 0.27 mm and 4.70 ± 0.24 mm (P < 0.001), respectively. Seven years postoperatively, EOZ following SMILE and FS-LASIK decreased to 5.03 ± 0.28 mm and 4.63 ± 0.23 mm (P < 0.001), respectively. At postoperative 7 years, the percentages of EOZ/POZ were negatively correlated with Q-value changes (ß = -5.120, P = 0.009) following SMILE and positively correlated with the cylinder correction (ß = 1.184, P = 0.004) following FS-LASIK. The induced spherical aberrations in the SMILE group were less than those in the FS-LASIK group (P < 0.05) and were negatively correlated with the EOZ/POZ (ß = -16.653, P < 0.001). CONCLUSIONS: The EOZ following SMILE was larger than that following FS-LASIK in the long postoperative term for moderate and high myopia. Furthermore, a continual reduction in the EOZ was noted after both surgical modalities.


Assuntos
Topografia da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Refração Ocular , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Feminino , Adulto , Masculino , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Lasers de Excimer/uso terapêutico , Adulto Jovem , Seguimentos , Estudos Retrospectivos , Miopia/cirurgia , Miopia/fisiopatologia , Substância Própria/cirurgia , Cirurgia da Córnea a Laser/métodos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Córnea/cirurgia , Miopia Degenerativa/cirurgia , Miopia Degenerativa/fisiopatologia , Período Pós-Operatório
2.
PeerJ ; 12: e17940, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39184392

RESUMO

Purpose: To compare the visual quality after wavefront-guided femtosecond LASIK (WFG FS-LASIK) in patients with different levels of preoperative total ocular higher-order aberrations to guide clinical decision-making regarding patient selection and treatment strategies. Methods: This study included 112 right eyes of 112 patients who previously underwent WFG FS-LASIK for correcting myopia and myopic astigmatism. The patients were divided into two groups based on the mean values of preoperative total ocular HOAs (0.30 ± 0.09 µm): HOA ≤ 0.3 and > 0.3 groups. The visual acuity, manifest refraction, corneal Strehl ratio (SR), root mean square (RMS) of corneal and ocular aberrations, and area under the log contrast sensitivity function (AULCSF) of both groups were compared preoperatively and at 1, 3, 6, and 12 months postoperatively. Results: The induced ocular HOAs and coma (Δ = 1 mo - Preop) were significantly lower in the HOAs > 0.3 group than in the HOAs ≤ 0.3 group (ΔHOAs: 0.39 ± 0.19 vs. 0.29 ± 0.18 µm, t = 2.797, P = 0.006; Δ coma: 0.30 ± 0.19 vs. 0.20 ± 0.21 µm, t = 2.542, P = 0.012). In the HOAs > 0.3 group, ΔHOAs were negatively correlated with the preoperative ocular HOAs (r = -0.315, P = 0.019). In the HOAs ≤ 0.3 group, the regression equation for Δ HOAs = 0.098 + 0.053 |SE| (F = 21.756, P < 0.001). In the HOAs > 0.3 group, the regression equation for ΔHOAs = 0.534 - 1.081 HOAs + 0.038|Sphere| (F = 7.954, P = 0.001). The postoperative uncorrected distance visual acuity, spherical equivalent, corneal aberrations, SR and AULCSF of both groups were similar (all P > 0.05). Furthermore, the ocular aberrations were not significantly different between both groups at 3, 6, and 12 months postoperatively (all P > 0.05). In addition, compared with the preoperative period, the AULCSF of both groups were significantly increased in the postoperative period (all P < 0.05). Conclusions: The induced ocular HOAs and coma in HOAs > 0.3 group were lower. However, both groups achieved equivalent and excellent visual quality after WFG FS-LASIK. WFG FS-LASIK may provide significant visual benefits for a wider range of patients.


Assuntos
Astigmatismo , Aberrações de Frente de Onda da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Feminino , Masculino , Acuidade Visual/fisiologia , Adulto , Estudos Retrospectivos , Miopia/cirurgia , Miopia/fisiopatologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Astigmatismo/cirurgia , Astigmatismo/fisiopatologia , Adulto Jovem , Refração Ocular/fisiologia , Resultado do Tratamento , Pessoa de Meia-Idade , Sensibilidades de Contraste/fisiologia
3.
BMC Ophthalmol ; 24(1): 328, 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39107739

RESUMO

BACKGROUND: Visual impairment can cause balance problems. Therefore, visual impairment caused by an increase in corneal deviations can lead to sudden and unstable loads in the lower extremities. We aimed to investigate the possible relationship between low-energy meniscal injuries and corneal structural measures. METHODS: This prospective, observational study included individuals aged between 18-40 years with a normal body-mass index. The study group consisted of 54 patients with grade 2 or 3 meniscus injuries after low-energy activity. The control group consisted of 54 healthy individuals without any complaints in the knee joint. The corneal parameters of all participants were evaluated with a Scheimpflug corneal topography and specular microscopy device. Simulated keratometry (SimK), minimum central corneal thickness (MCCT), cylindrical diopter (ClyD), corneal volume (CVol) spheric aberrations (SphAbb), high-order aberration (HOA), coma values, and endothelial parameters were recorded. RESULTS: The research and control groups were similar in terms of age, body mass index, and gender distribution. There was no significant difference between the groups in the corneal SimK and CylD, parameters. However, HOA, Coma, SphAbb, and cell variability (Cv) values were significantly higher in the study group, and contrarily MCCT, CVol, and endothelial count (Cd) values were significantly lower. CONCLUSIONS: Our findings suggest that individuals with relatively lower MCCT values tend to develop meniscal damage after low-energy activity. Hence, the loss of corneal strength in these patients may be a sign of possible weakness in the meniscus. The HOA value above 0.26, the coma value above 0.16, and the SphAbb value above 0.1 may significantly increase the possible meniscus injury.


Assuntos
Topografia da Córnea , Humanos , Masculino , Feminino , Estudos Prospectivos , Adulto , Adulto Jovem , Adolescente , Lesões do Menisco Tibial/fisiopatologia , Córnea/patologia , Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Acuidade Visual/fisiologia
4.
Int Ophthalmol ; 44(1): 331, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39037500

RESUMO

PURPOSE: To compare the clinical outcomes of myopiacorrected with corneal-wavefront-guided (CWG) laser in situ keratomileusis (LASIK) with AMARIS 1050S (SCHWIND eye-tech-solutions GmbH & Co. KG) and corneal-topography-guided (CTG) LASIK with WaveLight EX500 (Alcon Laboratories, Fort Worth, TX). METHODS: In this prospective, pseudo-randomized expanded cohort study, a total of 266 patients were subjected to binocular LASIK surgery, either with WaveLight EX500 (WaveLight group) or Amaris 1050S (AMARIS group) platforms. Data related to right eyes were selected for analysis. Corneal higher-order aberration (HOA) was selected as the primary endpoint; while visual acuity and refraction were the secondary endpoints. All the endpoints were assessed at 3 months postoperatively. RESULTS: There were 134 eyes in the AMARIS group and 132 eyes in the WaveLight group. After 3 months of postoperative follow-up, spherical and coma aberrations were significantly lower (P < 0.05) in the WaveLight group (spherical aberration: - 0.104 ± 0.199 µm; coma aberration: - 0.117 ± 0.202 µm) in comparison with the AMARIS group (spherical aberrations: 0.254 ± 0.146 µm; coma aberrations: 0.316 ± 0.297 µm). In the AMARIS group, 96.3% of the eyes achieved an uncorrected distance visual acuity (UDVA) of 20/20 while in the WaveLight group, 96.2% of the eyes achieved an UDVA of 20/20. Furthermore, the mean postoperative manifest refraction spherical equivalent (MRSE) was - 0.02 ± 0.28 in the AMARIS group and - 0.05 ± 0.21 in the WaveLight group (P = 0.34). CONCLUSIONS: Both WaveLight EX500 and Amaris 1050S LASIK showed excellent refractive and visual outcomes. In addition, the WaveLight group showed minimal spherical and coma aberrations when compared to the AMARIS group.


Assuntos
Córnea , Topografia da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Refração Ocular , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Feminino , Estudos Prospectivos , Masculino , Adulto , Refração Ocular/fisiologia , Miopia/cirurgia , Miopia/fisiopatologia , Lasers de Excimer/uso terapêutico , Córnea/cirurgia , Adulto Jovem , Resultado do Tratamento , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/diagnóstico , Seguimentos
5.
J Refract Surg ; 40(7): e490-e498, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007811

RESUMO

PURPOSE: To compare the objective visual quality of moderate-to-high myopia corrected by small incision lenticule extraction (SMILE) and transepithelial photorefractive keratectomy (TransPRK) at a 1,050-Hz ablation frequency, assisted by Smart-Pulse technology (SCHWIND eye-tech-solutions). METHODS: This study involved 123 patients (123 eyes) with moderate-to-high myopia between July 2020 and January 2021. They were categorized into the SMILE group (67 patients, 67 eyes) and the TransPRK group (56 patients, 56 eyes). Follow-ups were conducted at 6 months postoperatively to record the logarithm of the minimum angle of resolution visual acuity, and the Strehl ratio and higher order aberrations were measured using the Sirius anterior segment analysis device (SCHWIND eye-tech-solutions) under a 6-mm pupil diameter at various postoperative intervals. RESULTS: At 1 week and 1 month postoperatively, the uncorrected distance visual acuity (UDVA) in the SMILE group was superior to that in the TransPRK group (P < .05 for both). At 1 week and 1 month postoperatively, the Strehl ratio value in the SMILE group was higher than that in the TransPRK group (P < .05 for both). At 1, 3, and 6 months postoperatively, coma was greater in the SMILE group than in the TransPRK group (P < .05 for all). Spherical aberrations were lower in the SMILE group than in the TransPRK group at 3 and 6 months postoperatively (P < .05). At 6 months postoperatively, UDVA was -0.09 ± 0.08 and -0.11 ± 0.05 logMAR in the SMILE and TransPRK groups, respectively, which exceeded their preoperative corrected distance visual acuity of -0.05 ± 0.04 and -0.09 ± 0.08 logMAR (all P < .001). Compared with preoperative values, the Strehl ratio, total higher order, coma, and spherical aberration differences were significantly increased postoperatively in both groups (all P < .001). CONCLUSIONS: Both surgical methods improved UDVA and each had its advantages. The visual quality of SMILE was superior at 1 week and 1 month postoperatively (Strehl ratio values were higher than those of the TransPRK group), and its spherical aberration was lower than that of the TransPRK group at 3 and 6 months; TransPRK with SmartPulse technology with a 1,050-Hz ablation frequency showed that coma was significantly lower than that of the SMILE group at 1, 3, and 6 months postoperatively. [J Refract Surg. 2024;40(7):e490-e498.].


Assuntos
Substância Própria , Lasers de Excimer , Ceratectomia Fotorrefrativa , Refração Ocular , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Lasers de Excimer/uso terapêutico , Feminino , Masculino , Ceratectomia Fotorrefrativa/métodos , Adulto , Refração Ocular/fisiologia , Adulto Jovem , Substância Própria/cirurgia , Cirurgia da Córnea a Laser/métodos , Miopia Degenerativa/cirurgia , Miopia Degenerativa/fisiopatologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Topografia da Córnea , Seguimentos , Estudos Prospectivos , Miopia/cirurgia , Miopia/fisiopatologia , Estudos Retrospectivos
6.
J Refract Surg ; 40(7): e499-e505, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007813

RESUMO

PURPOSE: To assess the effects of intraocular lens (IOL) decentration and tilt, as well as age, on postoperative visual function (corrected distance visual acuity [CDVA] and contrast sensitivity) by comparing an extended depth-of-focus IOL using higher order aspheric optics against a monofocal IOL from the same platform. METHODS: This retrospective observational study targeted patients without other eye diseases who underwent surgery to implant the Tecnis Eyhance OptiBlue or the monofocal IOL Tecnis OptiBlue 1-Piece (J&J Vision) during cataract surgery from November 2021 to December 2022. The effects of age, axial length, IOL decentration, tilt, and corneal higher order aberrations (HOAs) on the postoperative 5 m CDVA and area under log contrast sensitivity function (AULCSF) under photopic and scotopic conditions were evaluated within 3 months of surgery. RESULTS: No significant difference was found in postoperative CDVA between the Tecnis Eyhance OptiBlue group (n = 61 eyes) and the Tecnis OptiBlue 1-Piece group (n = 35 eyes), but AULCSF was significantly better in the Tecnis Eyhance OptiBlue group for photopic (1.58 ± 0.13 vs 1.46 ± 0.18; P = .002) and scotopic (1.71 ± 0.11 vs 1.59 ± 0.19; P = .002) eyes. Multivariate analysis showed a negative correlation between AULCSF and IOL decentration and age in the Tecnis Eyhance OptiBlue group (P < .01), with no significant correlation with tilt, axial length, and corneal HOAs. CONCLUSIONS: The Tecnis Eyhance OptiBlue yielded significantly better contrast sensitivity under photopic and scotopic conditions than the Tecnis OptiBlue 1-Piece. However, it is important to consider the effects of IOL decentration and age when evaluating the contrast sensitivity of the Tecnis Eyhance OptiBlue. [J Refract Surg. 2024;40(7):e499-e505.].


Assuntos
Sensibilidades de Contraste , Percepção de Profundidade , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Desenho de Prótese , Pseudofacia , Acuidade Visual , Humanos , Estudos Retrospectivos , Acuidade Visual/fisiologia , Masculino , Feminino , Sensibilidades de Contraste/fisiologia , Idoso , Pessoa de Meia-Idade , Pseudofacia/fisiopatologia , Percepção de Profundidade/fisiologia , Refração Ocular/fisiologia , Migração do Implante de Lente Intraocular/fisiopatologia , Idoso de 80 Anos ou mais , Período Pós-Operatório , Comprimento Axial do Olho , Aberrações de Frente de Onda da Córnea/fisiopatologia
7.
Invest Ophthalmol Vis Sci ; 65(6): 15, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38848076

RESUMO

Purpose: The purpose of this study was to investigate the associations between visual function and severity grading, corneal scatter, or higher-order aberrations (HOAs) in patients with Fuchs endothelial corneal dystrophy (FECD). Methods: This observational case series study included 49 eyes of 27 patients with FECD and 10 eyes of 10 healthy individuals. We evaluated corrected distance visual acuity (CDVA) using Landolt-C and Early Treatment Diabetic Retinopathy Study charts and contrast sensitivity using the CSV-1000E chart and CSV-1000RN letter chart. We analyzed the associations between visual function and explanatory variables, including age, modified Krachmer grade, central corneal thickness (CCT), anterior segment optical coherence tomography (AS-OCT)-based grade, HOAs, intraocular straylight, and corneal densitometry. We additionally conducted receiver operating characteristic (ROC) analysis to identify the corneal densitometry thresholds for decreased visual function. Results: There were significant associations between visual function and the modified Krachmer grade, CCT, AS-OCT-based grade, HOAs, intraocular straylight, and corneal densitometry. A modified Krachmer grade ≥ 3 was identified as a threshold for decreased visual function. Multivariate analysis showed that corneal densitometry was significantly associated with all visual function parameters, and HOAs were significantly associated with CDVA but not with contrast sensitivity. ROC analysis revealed that corneal densitometry of the posterior layer at 0 to 2 mm ≥ 10 grayscale units (GSU), was identified as a threshold for decreased visual function. Conclusions: HOAs, forward and backward light scatter affected visual function, with backward light scatter being the most influential. In patients with FECD, modified Krachmer grade ≥ 3 and corneal densitometry ≥ 10 GSU were thresholds for visual disturbance.


Assuntos
Sensibilidades de Contraste , Aberrações de Frente de Onda da Córnea , Distrofia Endotelial de Fuchs , Espalhamento de Radiação , Acuidade Visual , Humanos , Distrofia Endotelial de Fuchs/fisiopatologia , Distrofia Endotelial de Fuchs/diagnóstico , Feminino , Masculino , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Idoso , Sensibilidades de Contraste/fisiologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/diagnóstico , Tomografia de Coerência Óptica/métodos , Córnea/fisiopatologia , Córnea/diagnóstico por imagem , Índice de Gravidade de Doença , Curva ROC , Idoso de 80 Anos ou mais , Adulto
8.
J Refract Surg ; 40(6): e398-e406, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38848057

RESUMO

PURPOSE: To assess the visual and refractive outcomes of patients implanted with a toric extended depth-of-focus (EDOF) intraocular lens (IOL) following cataract surgery. METHODS: A total of 44 eyes implanted with the EDOF LuxSmart toric IOL were evaluated 4 to 6 months postoperatively. The main outcomes measurements evaluated were refractive error, rotational stability, distance, intermediate, and near visual acuities, defocus curve, photopic and mesopic contrast sensitivity, wavefront aberrations, and modulation transfer function, and the Catquest-9SF-questionnaire. RESULTS: The mean postoperative spherical equivalent and cylinder were -0.02 ± 0.26 and -0.17 ± 0.29 diopters (D), respectively. A total of 90.45% and 100% of the eyes had a postoperative spherical equivalent within ±0.50 and ±1.00 D, respectively (this being 93.18% and 100% for the refractive cylinder). The mean rotational stability was 0.61 ± 1.61 degrees. The mean binocular corrected distance visual acuity (CDVA), corrected distance intermediate visual acuity (CDIVA), and corrected distance near visual acuity (CDNVA) were -0.02 ± 0.06, 0.07 ± 0.08, and 0.26 ± 0.09 logMAR, respectively. The CDVA was 20/25 or better in 95.45% of patients, CDIVA was 20/25 or better in 72.73%, and CDNVA was 20/40 or better in 72.73%. The defocus curve showed good visual acuity at distance and intermediate vergences. The contrast sensitivity and optical quality outcomes were good with mean higher order, spherical, and coma aberration values of 0.161 ± 0.155, -0.019 ± 0.048, and 0.080 ± 0.065 µm, respectively. A total of 90.9% of patients were either fairly satisfied or very satisfied with their vision after the surgery, and 77.7% of patients reported no difficulties when reading text in newspapers. CONCLUSIONS: Implantation of the toric pure refractive EDOF technology IOL provides good refractive, optical, and visual quality at different distances, with high levels of patient satisfaction being reported. [J Refract Surg. 2024;40(6):e398-e406.].


Assuntos
Sensibilidades de Contraste , Aberrações de Frente de Onda da Córnea , Percepção de Profundidade , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Desenho de Prótese , Pseudofacia , Refração Ocular , Visão Binocular , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Sensibilidades de Contraste/fisiologia , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Percepção de Profundidade/fisiologia , Visão Binocular/fisiologia , Inquéritos e Questionários , Estudos Prospectivos , Satisfação do Paciente , Idoso de 80 Anos ou mais , Resultado do Tratamento
9.
J Refract Surg ; 40(6): e381-e391, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38848059

RESUMO

PURPOSE: To investigate the long-term visual quality and rotational stability after the implantation of Implantable Collamer Lens (ICL) and toric ICL (TICL) (STAAR Surgical) in patients with myopia older than 40 years. METHODS: This study included 82 eyes of 41 patients older than 40 years with myopia who underwent ICL/TICL V4c implantation. The refraction sphere, refraction cylinder, spherical equivalent (SE), uncorrected and corrected distance visual acuity, and anterior segmental parameters were measured preoperatively and at the 1-month, 3-month, and last follow-up visits at 33 to 58 months postoperatively (mean follow-up: 42.56 ± 7.17 months). Wavefront aberrations and TICL rotation were measured using OPD-Scan III (Nidek Co Ltd) at the last follow-up visit. RESULTS: At the last follow-up visit, the overall safety and efficacy index were 1.22 ± 0.26 and 0.88 ± 0.34, respectively, without significant differences between the ICL and TICL groups. Postoperative refraction cylinder was -0.95 ± 0.64 and -0.71 ± 0.54 diopters in the ICL and TICL groups, respectively. The average vault was 467.44 ± 231.98 µm. The average TICL rotation was 5.45 ± 6.61 degrees, positively correlated with the preoperative anterior chamber volume (R2 = 0.1118, P = .026) and clockwise TICL alignment degree (R2 = 0.3110, P = .007) and negatively correlated with the 1-month vault (R2 = 0.1218, P = .008). There were no significant differences in the total, corneal, or internal aberrations and modulation transfer function AreaRatio between the ICL and TICL groups. CONCLUSIONS: Both ICL and TICL presented satisfactory long-term safety, efficacy, and visual quality in patients older than 40 years. Postoperative TICL spontaneous rotation was within the manageable range in the long term. [J Refract Surg. 2024;40(6):e381-e391.].


Assuntos
Implante de Lente Intraocular , Miopia Degenerativa , Lentes Intraoculares Fácicas , Refração Ocular , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Seguimentos , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/cirurgia , Estudos Retrospectivos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Rotação
10.
Sci Rep ; 14(1): 14551, 2024 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-38914606

RESUMO

This study compares postoperative visual outcomes and optical aberrations after Small Incision Lenticule Extraction (SMILE) in patients with both small (S-Kappa: Kappa angle < 0.2 mm) and large Kappa (L-Kappa: Kappa angle ≥ 0.2 mm) angles. The evaluated aberrations include total higher-order aberrations (HOAs), horizontal coma (HC), vertical coma (VC), and spherical aberrations (SA), with procedures incorporating intraoperative Kappa angle adjustments. We retrospectively analyzed patient records undergoing SMILE utilizing linear mixed models (LMM). We assessed adjusted mean uncorrected distance visual acuity (UDVA), Strehl ratio (SR), total HOAs, VC, and SA at pupils of 3 mm and 6 mm for both S-Kappa and L-Kappa. The disparities between S-Kappa and L-Kappa were evaluated by LMM's adjusted mean differences. The differences in optical metrics were also assessed in eyes grouped by myopia levels: low, moderate, and high. A sensitivity analysis was conducted on a threshold of Kappa angle at 0.3 mm. Eight-five patients (169 eyes) were analyzed, and no significant pre-operative difference was found in UDVA (p = .222) or spherical equivalent (p = .433). Post-operative differences were found in SR at 3 mm pupil size (-0.06, p = .022), total HOA 3 mm (0.15, p = .022), HC 3 mm (0.04, p = .042), VC 3 mm and 6 mm (-0.08, p = .041; 0.04, p = .041). The stratified analysis for high myopia revealed significant differences in UDVA (-0.04, p = .037), HC 3 mm (0.07, p = .03), VC 6 mm (-0.21, p = .001), and SA 3 mm and 6 mm (0.07, p = .037; -0.09, p = .037). Sensitivity analysis showed no significant difference using a 0.3 mm Kappa threshold. While some optical aberrations exhibited statistical differences between S-Kappa and L-Kappa, their clinical significance is limited. Thus, a large Kappa angle might not substantially influence post-operative optical aberrations when intraoperative Kappa angle adjustments are implemented.


Assuntos
Miopia , Acuidade Visual , Humanos , Feminino , Masculino , Adulto , Estudos Retrospectivos , Miopia/cirurgia , Adulto Jovem , Cirurgia da Córnea a Laser/métodos , Cirurgia da Córnea a Laser/efeitos adversos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Resultado do Tratamento , Refração Ocular
11.
Int Ophthalmol ; 44(1): 292, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38940969

RESUMO

PURPOSE: Compared to Shack-Hartmann wavefront sensor (SHWS), the parameters of virtual SHWS (vSHWS) can be easily adjusted to obtain the optimal performance of aberration measurement. Its current optimal parameters are obtained with only a set of statistical aberrations and not statistically significant. Whether the above parameters are consistent with the statistical results of the optimal parameters corresponding to each set of aberrations, and which performance is better if not? The purpose of this study was to answer these questions. METHODS: The optimal parameters to reconstruct 624 sets of clinical ocular aberrations in the highest accuracy, including the numbers of sub-apertures (NSAs) and the expansion ratios (ERs) of electric field zero-padding, were determined sequentially in this work. By using wavefront-reconstruction accuracy as an evaluation index, the statistical optimal parameter configuration was selected from some possible configurations determined by the optimal NSAs and ERs. RESULTS: The statistical optimal parameters are consistent for normal and abnormal eyes. They are different from the optimal parameters obtained with a set of statistical aberrations from the same 624 sets of aberrations, and the performance using the former is better than that using the latter. The performance using a fixed set of statistical optimal parameters is even close to that using the respective optimal parameters corresponding to each set of aberrations. CONCLUSION: The vSHWS configured with a fixed set of statistical optimal parameters can be used for high-precision aberration measurement of both normal and abnormal eyes. The statistical optimal parameters are more suitable for vSHWS than the parameters obtained with a set of statistical aberrations. These conclusions are significant for the designs of vSHWS and also SHWS.


Assuntos
Aberrações de Frente de Onda da Córnea , Humanos , Aberrações de Frente de Onda da Córnea/diagnóstico , Aberrações de Frente de Onda da Córnea/fisiopatologia , Topografia da Córnea/métodos , Aberrometria/métodos , Refração Ocular/fisiologia , Acuidade Visual/fisiologia
12.
Sensors (Basel) ; 24(12)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38931650

RESUMO

The objective of this study was to assess the effect of sustained reading on the temporal changes in the wavefront error in the presbyopic eye. The wavefront aberration of the eyes was measured using an IRX3 Shack-Hartmann aberrometer before and after (immediately, 5 min, and 10 min after) a reading task. Temporal changes in C20, C40, and C3-1 coefficient values of the eyes were plotted, showing a predominant number of V-shaped patterns (for C40 and C3-1) and inverse V-shaped patterns (for C20) among the study group, and the percentages (between 27 and 73%) were reported. The median of the total RMS of aberrations and the RMS of HOA (higher-order aberrations), which included comatic (3rd order) and spherical-like aberrations (4th and 6th order), increased immediately after finishing the near-vision reading task and then decreased. The median of RMS of comatic aberrations had a similar pattern of variations, while the median of RMS of spherical-like aberrations displayed an opposite pattern. Simulating the aberration changes due to lens decentration caused by relaxed zonules during 4 D accommodation in an eye model demonstrated that the expected range of changes for the vertical coma and spherical aberrations are in the order of 0.001 and 0.01 µm, respectively, which could justify why the observed changes were not statistically significant. The observed dynamic changes in HOA might be linked to the biomechanical characteristics and alterations in the displacement of the crystalline lens following prolonged near-vision tasks in presbyopic people. Although some predominant patterns under some conditions were shown, they exhibit considerable inter-subject and inter-ocular variability. This might be due to slight misalignments while fixating on the internal extended object in the aberrometer.


Assuntos
Presbiopia , Leitura , Humanos , Presbiopia/fisiopatologia , Masculino , Feminino , Pessoa de Meia-Idade , Aberrometria , Acomodação Ocular/fisiologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Idoso
13.
J Refract Surg ; 40(6): e420-e434, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38848055

RESUMO

PURPOSE: To discuss factors influencing corneal aberrations that might influence the optical quality after intraocular lens (IOL) implantation. METHODS: PubMed and Scopus were the main resources used to search the medical literature. An extensive search was performed to identify relevant articles concerning factors influencing the level of corneal aberrations as of August 27, 2023. The following keywords were used in various combinations: corneal, aberrations, defocus, astigmatism, spherical aberration, coma, trefoil, quadrafoil, intraocular lens, and IOL. RESULTS: Conclusive evidence is lacking regarding the correlation between age and changes in corneal aberrations. Patients with astigmatism have greater corneal higher-order aberrations than those with minimal astigmatism, particularly concerning trefoil and coma. Increased levels of corneal higher-order aberrations are noted following contact lens wear, in patients with dry eye disease, and with pterygium. Increased higher-order aberrations have been reported following corneal refractive surgery and for 3 months following trabeculectomy; regarding intraocular lens surgery, the results remain controversial. CONCLUSIONS: Several factors influence the level of corneal higher-order aberrations. Multifocal and extended depth-of-focus IOLs can share similarities in their optical properties, and the main difference arises in their design and performance with respect to spherical aberration. Preoperative evaluation is critical for proper IOL choice, particularly in corneas with risk of high levels of aberrations. [J Refract Surg. 2024;40(6):e420-e434.].


Assuntos
Aberrações de Frente de Onda da Córnea , Implante de Lente Intraocular , Refração Ocular , Acuidade Visual , Humanos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/etiologia , Fatores de Risco , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Lentes Intraoculares Multifocais , Percepção de Profundidade/fisiologia , Topografia da Córnea , Córnea/fisiopatologia
14.
Korean J Ophthalmol ; 38(4): 275-283, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38897594

RESUMO

PURPOSE: To evaluate the outcomes of wavefront-optimized (WFO) and topography-guided (TG) transepithelial photorefractive keratectomy (transPRK) in the treatment of myopia and myopic astigmatism. METHODS: Patients who underwent transPRK using the WaveLight EX500 excimer laser for the correction of myopia and myopic astigmatism between January 2022 and March 2023 were divided into groups of WFO transPRK (77 eyes of 36 patients) or TG transPRK (63 eyes of 31 patients) in this retrospective, observational cohort study. The preoperative and postoperative 3-month refractive and visual outcomes of the two groups were analyzed. RESULTS: In both groups, the uncorrected distance visual acuity was 0.0 logarithm of the minimum angle of resolution or better in 95% of eyes 3 months postoperatively, and the mean manifest refraction spherical equivalent was within ±1.0 diopter in 90% of eyes. No significant differences were observed between the groups in terms of the uncorrected distance visual acuity or astigmatism. A significant induction of higher order aberrations (HOAs) was observed in both groups. However, the induction of total corneal HOAs (p = 0.014) and spherical aberrations (p < 0.001) was significantly lower in the TG group than that in the WFO group. CONCLUSIONS: WFO and TG transPRK effectively improved the visual and refractive outcomes; however, the induction of total corneal HOAs and spherical aberration was lesser following the TG ablation.


Assuntos
Topografia da Córnea , Lasers de Excimer , Miopia , Ceratectomia Fotorrefrativa , Refração Ocular , Acuidade Visual , Humanos , Estudos Retrospectivos , Ceratectomia Fotorrefrativa/métodos , Feminino , Masculino , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Adulto , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Miopia/fisiopatologia , Resultado do Tratamento , Adulto Jovem , Astigmatismo/cirurgia , Astigmatismo/fisiopatologia , Seguimentos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/diagnóstico , Cirurgia Assistida por Computador/métodos
15.
J Refract Surg ; 40(5): e291-e303, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717083

RESUMO

PURPOSE: To compare differences in corneal densitometry (CD) and higher order aberrations (HOAs) in eyes that underwent small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for the treatment of myopia and myopic astigmatism at postoperative months 3, 6, and 12, and to evaluate their changes in a separate cohort of eyes after SMILE enhancement. METHODS: In this prospective, randomized, paired-eye clinical trial, consecutive eligible participants were randomized to undergo SMILE or FS-LASIK in either eye. Main outcome measures were CD and HOAs preoperatively and at 3, 6, and 12 months postoperatively. A separate cohort of consecutive patients who had SMILE and underwent enhancement were also included for comparison. RESULTS: For CD, no significant differences were found between SMILE and FS-LASIK up to month 12. For HOA measured by wavefront aberrometry, both SMILE and FS-LASIK had an increase in total root mean square (RMS) HOAs, spherical aberration (SA), and vertical coma up to month 12. SMILE had an additional increase in vertical quatrefoil, and FS-LASIK had an increase in horizontal coma at month 12. FS-LASIK had higher SA than SMILE, whereas SMILE had higher vertical quatrefoil than FS-LASIK at month 12. Central and posterior zone CD had significantly decreased after SMILE enhancement compared to after primary SMILE up to 2 years after enhancement. RMS HOAs, lower order aberrations, and SA were all increased after SMILE enhancement compared to after primary SMILE. CONCLUSIONS: SMILE induced lower SA but higher vertical quatrefoil than FS-LASIK at 1 year. Both SMILE and FS-LASIK had similar increases in RMS HOAs and vertical coma up to 1 year. There were no differences in CD between both groups. SMILE enhancement additionally had decreased central and posterior CD but greater RMS HOAs and SA compared to primary SMILE. [J Refract Surg. 2024;40(5):e291-e303.].


Assuntos
Aberrometria , Astigmatismo , Córnea , Substância Própria , Aberrações de Frente de Onda da Córnea , Densitometria , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Refração Ocular , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Estudos Prospectivos , Miopia/cirurgia , Miopia/fisiopatologia , Adulto , Feminino , Masculino , Lasers de Excimer/uso terapêutico , Acuidade Visual/fisiologia , Substância Própria/cirurgia , Córnea/cirurgia , Córnea/fisiopatologia , Adulto Jovem , Refração Ocular/fisiologia , Astigmatismo/cirurgia , Astigmatismo/fisiopatologia , Cirurgia da Córnea a Laser/métodos , Topografia da Córnea
16.
J Cataract Refract Surg ; 50(9): 930-935, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38742939

RESUMO

PURPOSE: To investigate the impact of corneal higher-order aberrations (HOAs) on predicted corrected distance visual acuity (CDVA) in patients with keratoconus at varying simulated pupil apertures. SETTING: Ophthalmology Clinics, Medical University of South Carolina, Charleston, South Carolina. DESIGN: Retrospective chart review study. METHODS: 56 eyes with keratoconus were examined using Scheimpflug tomography during routine examinations before medical intervention. The severity of keratoconus was graded using the Amsler-Krumeich classification. Zernike analysis was used to obtain corneal aberrations using simulated pupil diameters of 6 mm, 4 mm, and 2 mm. These data were extrapolated to obtain the total root mean square HOAs for a 1.6 mm simulated pupil to evaluate the potential effect of a small aperture intraocular lens (IOL). Correlation analysis was used to study the impact and relative contributions of HOAs on CDVA. Convolution of HOAs from OPD-Scan III provided a clinical method to predict CDVA with different simulated pupil sizes in corneas with irregular astigmatism. RESULTS: There were statistically significant positive correlations between photopic CDVA and the magnitude of total and individual (coma, spherical aberration, and trefoil) HOAs in this cohort of keratoconus participants. A keratoconus case with the small aperture IOL confirms the improvement in vision due to the pinhole effect. CONCLUSIONS: The small aperture IOL is expected to markedly reduce aberrations in patients with keratoconus up to Amsler-Krumeich class 4 severity to levels consistent with the levels seen in healthy patients. Convolution of corneal HOAs with the Early Treatment Diabetic Retinopathy Study chart provides a useful simulation of the impact of pinhole optics in aberrated eyes.


Assuntos
Topografia da Córnea , Aberrações de Frente de Onda da Córnea , Ceratocone , Implante de Lente Intraocular , Lentes Intraoculares , Acuidade Visual , Humanos , Ceratocone/fisiopatologia , Ceratocone/diagnóstico , Acuidade Visual/fisiologia , Estudos Retrospectivos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Adulto Jovem
17.
J Cataract Refract Surg ; 50(9): 919-925, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38758195

RESUMO

PURPOSE: To evaluate visual outcomes of high hyperopic laser in situ keratomileusis (LASIK), using corneal aspherization to control the induced spherical aberration. SETTING: Fondation Ophtalmologique Adolphe de Rothschild, Paris, France. DESIGN: Prospective interventional case series. METHODS: Prospective interventional study of consecutive high hyperopes (≥+3 diopters [D] of spherical equivalent [SE]) undergoing LASIK with the WaveLight FS200 femtosecond and EX500 excimer laser platform. An aspheric ablation profile (planned change in corneal asphericity ΔQ = +0.2) was delivered using the Custom-Q nomogram on an optical zone of ≥6.5 mm centered near the corneal vertex. Uncorrected corrected distance visual acuity (UDVA) and corrected distance visual acuity, as well as changes in SE, corneal asphericity (ΔQ), and higher-order aberrations, were analyzed preoperatively and on day 1, 1, 3, 6, and 12 months. RESULTS: 117 eyes of 63 patients (mean age of 30.1 ± 5.6 years) were included. Preoperatively and at 12 months postoperatively, the mean SE was 5.1 ± 1.1 D and 0.00 ± 0.7 D, respectively. 88% of eyes achieved 0 logMAR or better UDVA at 12 months. 1 month postoperatively, there was a statistically significant induction of positive spherical aberration decreasing progressively and significantly until the last visit (preop SA4 = 0.09 ± 0.11 µm, day 1 SA4 = 0.30 ± 0.32 µm, 12 months SA4 = 0.08 ± 0.21 µm, P = .056). 2 eyes needed enhancement at 12 months. CONCLUSIONS: LASIK for high levels of hyperopia showed good outcomes mainly due to aspheric-customized ablation profile with a change of ΔQ = +0.2 in corneal asphericity.


Assuntos
Topografia da Córnea , Aberrações de Frente de Onda da Córnea , Hiperopia , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Refração Ocular , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Hiperopia/cirurgia , Hiperopia/fisiopatologia , Estudos Prospectivos , Acuidade Visual/fisiologia , Adulto , Lasers de Excimer/uso terapêutico , Refração Ocular/fisiologia , Masculino , Feminino , Aberrações de Frente de Onda da Córnea/fisiopatologia , Córnea/cirurgia , Córnea/fisiopatologia , Adulto Jovem , Oftalmopatias Hereditárias
19.
Vestn Oftalmol ; 140(2): 48-53, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38742498

RESUMO

Purpose. The study investigates corneal and higher-order internal aberrations in patients with amblyopia of different etiologies and their relationship with visual acuity, refraction, axial length, and fixation parameters. MATERIAL AND METHODS: Forty-five patients (90 eyes) were examined. All patients were divided into five groups: 1 - with dysbinocular amblyopia; 2 - with refractive amblyopia; 3 - with anisometropic amblyopia; 4 - with relative amblyopia due to congenital myopia; 5 (control) - fellow eyes without amblyopia. Aberrometry was performed using the OPD-Scan III device (Nidek, Japan). Fixation parameters were studied on the MP-3 microperimeter (Nidek, Japan). Correlation analysis was performed using Pearson's linear correlation coefficient (r). RESULTS: In amblyopia associated with congenital myopia, a significant increase in corneal and internal aberrations RMS, Total HOA, astigmatism (V) (0.65±0.26; 1.01±0.31; 4.22±1.17; -2.17±0.72; 0.86±0.3, respectively; control group - 0.44±0.19; 0.58±0.27; 1.0±0.75; -0.94±0.89; 0.47±0.65) and internal spherical aberration (0.06±0.02; control group - 0.04±0.03) was found. In dysbinocular amblyopia, a significant increase in internal aberrations Trefoil (V) and Coma (H) (0.75±0.52 and 0.17±0.35, respectively; control group - 0.05±0.28 and -0.07±0.21) was found, which correlated with a decrease in fixation density in the 2° ring (r= -0.40, r= -0.41). CONCLUSIONS: The increased level of higher-order aberrations in amblyopia associated with congenital myopia is due to the anatomical and optical features of the eyes. The increase in internal aberrations Trefoil (V) and Coma (H) in dysbinocular amblyopia is associated with a mismatch of the optical elements of the eye due to impaired fixation, i.e., it is not the cause, but the consequence of amblyopia.


Assuntos
Ambliopia , Miopia , Acuidade Visual , Humanos , Ambliopia/etiologia , Ambliopia/fisiopatologia , Ambliopia/diagnóstico , Masculino , Criança , Feminino , Miopia/complicações , Miopia/fisiopatologia , Miopia/diagnóstico , Refração Ocular/fisiologia , Aberrometria/métodos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/etiologia , Aberrações de Frente de Onda da Córnea/diagnóstico
20.
J Refract Surg ; 40(5): e321-e327, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717082

RESUMO

PURPOSE: To evaluate the characteristic of corrective epithelial thickness after femtosecond laser-assisted lenticule intrastromal keratoplasty (LIKE) to correct moderate-to-high hyperopia. METHODS: The prospective case series study of the LIKE procedure was performed to correct moderate-to-high hyperopia. The epithelial thickness map was generated by anterior segment optical coherence tomography (AS-OCT) in the corneal central 9-mm zone. Keratometry and corneal higher order aberrations were analyzed by Pentacam (Oculus Optikgeräte GmbH) preoperatively and postoperatively. RESULTS: In the 26 eyes of 13 participants who underwent the LIKE procedure for moderate-to-high hyperopia, the attempted spherical equivalence (SEQ) was +6.50 ± 1.09 diopters (D). Compared to the preoperative epithelial thickness maps, the postoperative epithelial thickness had become significantly thinner in the central 5-mm zone; the difference was 6 to 7 µm. The paracentral epithelium performed nonuniform remodeling; the thinnest epithelial thickness was located in the inferotemporal section, which has the greatest difference from the superonasal; the difference between these two was approximately 3 µm. Through correlation analysis, it was found that the sections with thinner epithelium were significantly related to corneal curvature and corneal vertical coma. CONCLUSIONS: The LIKE procedure can be used to correct moderate-to-high hyperopia. This study further indicated the epithelial remodeling characteristic after the LIKE procedure: the central and paracentral corneal epithelial thickness becomes thinner, and the epithelial thickness distributes non-uniformly, which may be the important factor of the postoperative curvature asymmetric distribution and induction of corneal vertical coma. [J Refract Surg. 2024;40(5):e321-e327.].


Assuntos
Substância Própria , Topografia da Córnea , Epitélio Corneano , Hiperopia , Refração Ocular , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Hiperopia/cirurgia , Hiperopia/fisiopatologia , Estudos Prospectivos , Substância Própria/cirurgia , Substância Própria/patologia , Masculino , Feminino , Adulto , Acuidade Visual/fisiologia , Epitélio Corneano/cirurgia , Epitélio Corneano/patologia , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Lasers de Excimer/uso terapêutico , Adulto Jovem , Aberrações de Frente de Onda da Córnea/fisiopatologia , Cirurgia da Córnea a Laser/métodos , Oftalmopatias Hereditárias
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...