Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.301
Filtrar
1.
Chem Res Toxicol ; 37(7): 1113-1120, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38957009

RESUMO

Electronic cigarettes (ECs) emit many toxic substances, including metals, that can pose a threat to users and the environment. The toxicity of the emitted metals depends on their oxidation states. Hence, this study examines the oxidation states of metals observed in EC aerosols. X-ray photoelectron spectroscopy analysis of the filters that collected EC aerosols identified the oxidation states of five primary metals (based on surface sample analysis), including chromium(III) (close to 100%) under low power setting while a noticeable amount of chromium(VI) (15%) at higher power settings of the EC, and copper(II) (100%), zinc(II) (100%), nickel(II) (100%), lead(II) (65%), and lead(IV) (35%) regardless of power settings. This observation indicates that the increased temperature due to higher power settings could alter the oxidation states of certain metals. We noted that many metals were in their lesser toxic states; however, inhaling these metals may still pose health risks.


Assuntos
Aerossóis , Sistemas Eletrônicos de Liberação de Nicotina , Oxirredução , Aerossóis/química , Metais/química
2.
J Sep Sci ; 47(14): e2400250, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39034833

RESUMO

Reconstituted tobacco (RT) is a product made by reprocessing tobacco waste, experiencing a growing demand for heat-not-burn products. The purpose of this study is to analyze the main flavor ingredients in RT aerosol, as well as the transfer behavior of key flavor substances from substrates to aerosol and the concentrations of these compounds in the substrate after heating. First, we demonstrated that the odor of four RT aerosol samples could be distinguished using an electronic nose. Through non-targeted analysis, 93 volatile compounds were detected by gas chromatography-mass spectrometry, and 286 non/semi-volatile compounds were identified by ultra-high-performance liquid electrophoresis chromatography-mass spectrometry in aerosol. Furthermore, we found that the formation of RT aerosol involves primarily evaporation and distillation, however, the total content delivered from unheated RT samples to aerosol remains relatively low due to compound volatility and cigarette filtration. Thermal reactions during heating indicated the pyrolysis of chlorogenic acid to generate catechol and resorcinol, while Maillard reactions involving glucose and proline produced 2,3-dihydro-3,5-dihydroxy-6-methyl-4h-pyran-4-one. The study highlighted that heating RT at approximately 300°C could mitigate the production of harmful substances while still providing a familiar sensory experience with combusted tobacco.


Assuntos
Aromatizantes , Cromatografia Gasosa-Espectrometria de Massas , Nicotiana , Aromatizantes/análise , Aromatizantes/química , Nicotiana/química , Temperatura Alta , Aerossóis/química , Aerossóis/análise , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/química , Produtos do Tabaco/análise , Calefação , Odorantes/análise
3.
Talanta ; 277: 126359, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38852340

RESUMO

Characterization of aminoglycoside antibiotics like ribostamycin is important due to the complex composition and common toxic impurities. Aerosol detectors are often employed for determination of these non-absorbent analytes. In this work, a robust and cost-effective method was developed for simultaneous detection of ribostamycin and its related substances using high-performance liquid chromatography (HPLC) with a relative new aerosol detector named nano-quantity analyte detector (NQAD). With the introduction of less toxic but more compatible ion-pairs pentafluoropropionic acid (PFPA) and trifluoroacetic acid (TFA) in the eluent, an optimized separation effect was achieved. Compared with the other two aerosol detectors namely ELSD (evaporative light scattering detector) and CAD (charged aerosol detector), method verification and quantitative detection results revealed that NQAD had higher sensitivity than ELSD with a 0.8 µg/mL limit of detection, as well as wider linear range (from 2 µg/mL to 1000 µg/mL) than both CAD (from 2 µg/mL to 200 µg/mL) and ELSD (from 8 µg/mL to 200 µg/mL) detector. The performance of NQAD helped to realize detection of ribostamycin and its impurities with significant concentration differences in a single run. With a cation suppressor to eliminate the ion-suppression caused by the ion-pairs in the eluent, the structure of nine impurities in ribostamycin sample was characterized by liquid chromatography-mass spectrum (LC-MS). Both external standard and area normalization calculation were investigated, and NQAD obtained more accurate results due to its full-range linear response-to-concentration relationship, providing an alternative for routine quality control of multi analyte systems.


Assuntos
Aerossóis , Aerossóis/análise , Aerossóis/química , Cromatografia Líquida de Alta Pressão/métodos , Contaminação de Medicamentos , Limite de Detecção , Antibacterianos/análise
4.
ACS Sens ; 9(6): 2915-2924, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38848499

RESUMO

Health and security concerns have made it essential to develop integrated, continuous collection and sensing platforms that are compact and capable of real-time detection. In this study, we numerically investigate the flow physics associated with the single-step collection and enrichment of aerosolized polystyrene microparticles into a flowing liquid using a stratified air-water flow in a U-shaped microchannel. We validate our simulation results by comparing them to experimental data from the literature. Additionally, we fabricate an identical microfluidic device using PDMS-based soft lithography and test it to corroborate the previously published experimental data. Diversion and entrapment efficiencies are used as evaluation metrics, both of which increase with increasing particle diameter and superficial air inlet velocity. Overall, our ANSYS Fluent two-dimensional (2D) and three-dimensional (3D) multiphase flow simulations exhibit a good agreement with our experimental data and data in the literature (average deviation of ∼11%) in terms of diversion efficiency. Simulations also found the entrapment efficiency to be lower than the diversion efficiency, indicating discrepancies in the literature in terms of captured particles. The effect of the Dean force on the flow physics was also investigated using 3D simulations. We found that the effect of the Dean flow was more dominant relative to the centrifugal force on the smaller particles (e.g., 0.65 µm) compared to the larger particles (e.g., 2.1 µm). Increasing the superficial air inlet velocity also increases the effect of the centrifugal forces relative to the Dean forces. Overall, this experimentally validated multiphase model decouples and investigates the multiple and simultaneous forces on aerosolized particles flowing through a curved microchannel, which is crucial for designing more efficient capture devices. Once integrated with a microfluidic-based biosensor, this stratified flow-based microfluidic biothreat capture platform should deliver continuous sensor-ready enriched biosamples for real-time sensing.


Assuntos
Aerossóis , Tamanho da Partícula , Poliestirenos , Aerossóis/química , Aerossóis/análise , Poliestirenos/química , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Dispositivos Lab-On-A-Chip , Microfluídica/métodos , Microfluídica/instrumentação
5.
Anal Chem ; 96(26): 10648-10653, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38896456

RESUMO

Fentanyl is an extremely potent opioid that is commonly laced into other drugs. Fentanyl poses a danger to users but also to responders or bystanders who may unknowingly ingest a lethal dose (∼2 mg) of fentanyl from aerosolized powder or vapor. Electrochemistry offers a small, simple, and affordable platform for the direct detection of illicit substances; however, it is largely limited to solution-phase measurements. Here, we demonstrate the hands-free capture and electroanalyzation of aerosols containing fentanyl. A novel electrochemical cell is constructed by a microwire (cylindrical working electrode) traversing an ionic liquid film that is suspended within a conductive loop (reference/counter electrode). We provide a quantitative finite element simulation of the resulting electrochemical system. The suspended film maintains a high-surface area:volume, allowing the electrochemical cell to act as an effective aerosol collector. The low vapor pressure (negligible evaporation) of ionic liquid makes it a robust candidate for in-field applications, and the use of a hydrophobic ionic liquid allows for the extraction of fentanyl from solids and sprayed aqueous aerosols.


Assuntos
Aerossóis , Técnicas Eletroquímicas , Fentanila , Fentanila/análise , Aerossóis/química , Aerossóis/análise , Líquidos Iônicos/química , Eletrodos , Analgésicos Opioides/análise
6.
J Appl Biomater Funct Mater ; 22: 22808000241261904, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38907595

RESUMO

Atomization is a treatment method to make inhaled liquids into aerosols and transport them to target organs in the form of fog or smoke. It has the advantages of improving the bioavailability of drugs, being painless, and non-invasive, and is now widely used in the treatment of lung and oral lesions. Aerosol inhalation as the route of administration of therapeutic proteins holds significant promise due to its ability to achieve high bioavailability in non-invasive pathways. Currently, a great number of therapeutic proteins such as alpha-1 antitrypsin and Dornase alfa are effective. Recombinant humanized collagen type III (rhCol III) as a therapeutic protein is widely used in the biomedical field, but atomization is not a common route of administration for rhCol III, presenting great potential for development. However, the structural stability of recombinant humanized collagen after atomization needs further investigation. This study demonstrated that the rhCol III subjected to atomization through compressed air had retained its original molecular weights, triple helical structures, and the ability to promote cell adhesion. In other words, the rhCol III can maintain its stability after undergoing atomization. Although more research is required to determine the efficacy and safety of the rhCol III after atomization, this study can lay the groundwork for future research.


Assuntos
Colágeno Tipo III , Proteínas Recombinantes , Proteínas Recombinantes/química , Humanos , Colágeno Tipo III/química , Colágeno Tipo III/metabolismo , Aerossóis/química
7.
Chem Res Toxicol ; 37(7): 1155-1170, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38924487

RESUMO

In 2012, the U.S. Food & Drug Administration (FDA) published an established list of 93 harmful and potentially harmful constituents (HPHCs) targeting four tobacco product types (cigarettes, cigarette tobacco, roll-your-own tobacco, smokeless tobacco). In 2016, the FDA finalized the deeming rule to regulate electronic nicotine delivery systems (ENDS). However, knowledge gaps exist regarding whether certain HPHCs are present in ENDS e-liquids and aerosols. We identified and addressed these gaps by conducting literature searches and then experimentally quantifying HPHCs in the e-liquid and aerosol of 37 ENDS brands based on gaps in the literature. The literature searches identified 66 e-liquid HPHCs and 68 aerosol HPHCs that have limited to no information regarding the quantifiability of these constituents. A contracted ISO 17025 accredited laboratory performed the HPHC quantifications. The availability of validated analytical methods in the contracted laboratory determined the HPHCs included in the study scope (63/66 for e-liquids, 64/68 for aerosols). Combining the results from the quantifications and literature searches, 36 (39%) and 34 (37%) HPHCs were found quantifiable (≥limit of quantification [LOQ]) in ENDS e-liquids and aerosols, respectively, with 25 HPHCs being quantifiable in both matrices. Quantifiability results imply potential HPHC transfers between matrices, leaching from components, or formations from aerosol generation. The study results can inform the scientific basis for manufacturers and regulators regarding regulatory requirements for HPHC reporting. The HPHC quantities can also inform evaluations of the public health impact of ENDS and public communications regarding ENDS health risks.


Assuntos
Aerossóis , Sistemas Eletrônicos de Liberação de Nicotina , Aerossóis/análise , Aerossóis/química , Humanos , Nicotina/análise
8.
Environ Sci Process Impacts ; 26(7): 1156-1170, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-38812434

RESUMO

One major challenge in predicting secondary organic aerosol (SOA) formation in the atmosphere is incomplete representation of biogenic volatile organic compounds (BVOCs) emitted from plants, particularly those that are emitted as a result of stress - a condition that is becoming more frequent in a rapidly changing climate. One of the most common types of BVOCs emitted by plants in response to environmental stress are acyclic terpenes. In this work, SOA is generated from the photooxidation of acyclic terpenes in an oxidation flow reactor and compared to SOA production from a reference cyclic terpene - α-pinene. The acyclic terpenes used as SOA precursors included ß-myrcene, ß-ocimene, and linalool. Results showed that oxidation of all acyclic terpenes had lower SOA yields measured after 4 days photochemical age, in comparison to α-pinene. However, there was also evidence that the condensed organic products that formed, while a smaller amount overall, had a higher oligomeric content. In particular, ß-ocimene SOA had higher oligomeric content than all the other chemical systems studied. SOA composition data from ultra-high performance liquid chromatography with electrospray ionization mass spectrometry (UHPLC-ESI-MS) was combined with mechanistic modeling using the Generator for Explicit Chemistry and Kinetics of Organics in the Atmosphere (GECKO-A) to explore chemical mechanisms that could lead to this oligomer formation. Calculations based on composition data suggested that ß-ocimene SOA was more viscous with a higher glass transition temperature than other SOA generated from acyclic terpene oxidation. This was attributed to a higher oligomeric content compared to other SOA systems studied. These results contribute to novel chemical insights about SOA formation from acyclic terpenes and relevant chemistry processes, highlighting the importance of improving underrepresented biogenic SOA formation in chemical transport models.


Assuntos
Aerossóis , Poluentes Atmosféricos , Oxirredução , Terpenos , Compostos Orgânicos Voláteis , Aerossóis/química , Compostos Orgânicos Voláteis/química , Poluentes Atmosféricos/química , Poluentes Atmosféricos/análise , Terpenos/química , Monoterpenos Acíclicos/química , Modelos Químicos , Processos Fotoquímicos , Atmosfera/química , Monoterpenos Bicíclicos/química , Monoterpenos/química , Monitoramento Ambiental/métodos
9.
ACS Sens ; 9(6): 3096-3104, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38753414

RESUMO

Lateral flow assays (LFAs) are currently the most popular point-of-care diagnostics, rapidly transforming disease diagnosis from expensive doctor checkups and laboratory-based tests to potential on-the-shelf commodities. Yet, their sensitive element, a monoclonal antibody, is expensive to formulate, and their long-term storage depends on refrigeration technology that cannot be met in resource-limited areas. In this work, LCB1 affibodies (antibody mimetic miniproteins) were conjugated to bovine serum albumin (BSA) to afford a high-avidity synthetic capture (LCB1-BSA) capable of detecting the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein and virus like particles (VLPs). Substituting the monoclonal antibody 2B04 for LCB1-BSA (stable up to 60 °C) significantly improved the thermal stability, shelf life, and affordability of plasmonic-fluor-based LFAs (p-LFAs). Furthermore, this substitution significantly improved the sensitivity of p-LFAs toward the spike protein and VLPs with precise quantitative ability over 2 and 3 orders of magnitude, respectively. LCB1-BSA sensors could detect VLPs at 100-fold lower concentrations, and this improvement, combined with their robust nature, enabled us to develop an aerosol sampling technology to detect aerosolized viral particles. Synthetic captures like LCB1-BSA can increase the ultrasensitivity, availability, sustainability, and long-term accuracy of LFAs while also decreasing their manufacturing costs.


Assuntos
Aerossóis , Antígenos Virais , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , Aerossóis/química , Glicoproteína da Espícula de Coronavírus/imunologia , Antígenos Virais/análise , Antígenos Virais/imunologia , Soroalbumina Bovina/química , COVID-19/diagnóstico , COVID-19/virologia , Humanos , Anticorpos Monoclonais/imunologia , Anticorpos Monoclonais/química , Imunoensaio/métodos , Temperatura , Limite de Detecção
10.
Chem Res Toxicol ; 37(6): 981-990, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38776470

RESUMO

The production of e-cigarette aerosols through vaping processes is known to cause the formation of various free radicals and reactive oxygen species (ROS). Despite the well-known oxidative potential and cytotoxicity of fresh vaping emissions, the effects of chemical aging on exhaled vaping aerosols by indoor atmospheric oxidants are yet to be elucidated. Terpenes are commonly found in e-liquids as flavor additives. In the presence of indoor ozone (O3), e-cigarette aerosols that contain terpene flavorings can undergo chemical transformations, further producing ROS and reactive carbonyl species. Here, we simulated the aging process of the e-cigarette emissions in a 2 m3 FEP film chamber with 100 ppbv of O3 exposure for an hour. The aged vaping aerosols, along with fresh aerosols, were collected to detect the presence of ROS. The aged particles exhibited 2- to 11-fold greater oxidative potential, and further analysis showed that these particles formed a greater number of radicals in aqueous conditions. The aging process induced the formation of various alkyl hydroperoxides (ROOH), and through iodometric quantification, we saw that our aged vaping particles contained significantly greater amounts of these hydroperoxides than their fresh counterparts. Bronchial epithelial cells exposed to aged vaping aerosols exhibited an upregulation of the oxidative stress genes, HMOX-1 and GSTP1, indicating the potential for inhalation toxicity. This work highlights the indirect danger of vaping in environments with high ground-level O3, which can chemically transform e-cigarette aerosols into new particles that can induce greater oxidative damage than fresh e-cigarette aerosols. Given that the toxicological characteristics of e-cigarettes are mainly associated with the inhalation of fresh aerosols in current studies, our work may provide a perspective that characterizes vaping exposure under secondhand or thirdhand conditions as a significant health risk.


Assuntos
Aromatizantes , Estresse Oxidativo , Ozônio , Espécies Reativas de Oxigênio , Terpenos , Vaping , Ozônio/química , Estresse Oxidativo/efeitos dos fármacos , Espécies Reativas de Oxigênio/metabolismo , Humanos , Aromatizantes/química , Aromatizantes/análise , Vaping/efeitos adversos , Terpenos/química , Sistemas Eletrônicos de Liberação de Nicotina , Aerossóis/química
11.
Photochem Photobiol Sci ; 23(7): 1279-1294, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38762827

RESUMO

This study evaluated the health-related weighted ultraviolet radiation (UVR) due to the total ozone content (TOC) and the aerosol optical depth (AOD) changes. Clear-sky Ultraviolet Index (UVI), daily doses, and exposure times for erythema induction (Dery and Tery) and vitamin D synthesis (DvitD and TvitD) were computed by a radiative transfer estimator. TOC and AOD data were provided by six Earth System Models (ESMs) from the Coupled Model Intercomparison Project Phase 6 (CMIP6). For projections, we consider four Shared Socioeconomic Pathways scenarios-SSPs (SSP1-2.6, SSP2-4.5, SSP3-7.0, and SSP5-8.5)-and two time-slices (near: 2041-2060 and far future: 2081-2100). UVR projections showed pronounced changes for the summer hemispheres in the far future. TOC increases in mid- and high latitudes of the Southern Hemisphere caused decreases in UVR at the summer solstice. However, projections did not indicate sun-safe exposure conditions in South America, Australia, and Southern Africa. On the contrary, exposure around solar noon from 10 to 20 min will still be sufficient to induce erythema in skin type III individuals throughout this century. In southern Argentina and Chile, the UVR insufficiency for vitamin D synthesis at solar noon in skin type III remains the same during this century at the winter solstice. In the Northern Hemisphere, UVI and Dery at the summer solstice should remain high (UVI ≥ 8; Dery ~ 7.0 kJ m-2) in highly populated locations. Above 45 °N, UVR levels cannot be enough to synthesize vitamin D in skin type III during the boreal winter. Our results show that climate change will affect human health through excess or lack of solar UVR availability.


Assuntos
Aerossóis , Ozônio , Raios Ultravioleta , Aerossóis/química , Ozônio/química , Ozônio/análise , Humanos , América do Sul
12.
Int J Biol Macromol ; 271(Pt 2): 132526, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38782317

RESUMO

Layer-by-Layer (LbL) assembly of polyelectrolytes on a solid core particle is a well-established technique used to deliver drugs, proteins, regenerative medicines, combinatorial therapy, etc. It is a multifunctional delivery system which can be engineered using various core template particles and coating polymers. This study reports the development and in-vitro evaluation of LbL assembled particles for non-invasive inhaled delivery to the lungs. The LbL assembled particles were prepared by successively coating polyelectrolyte macromolecules, glycol chitosan and bovine serum albumin on 0.5- and 4.5-µm polystyrene particles. The LbL assembly of polyelectrolytes was confirmed by reversible change in zeta potential and sequential increase in the particle size after accumulation of the layer. The prepared LbL particles were further assessed for aerodynamic properties using two distinct nebulizers, and toxicity assessment in normal lung cells. The in-vitro aerosolization study performed using next generation impactor coupled with Pari LC Plus and Aeroeclipse nebulizer showed that both the LbL assembled 0.5 and 4.5-µm particles had MMAD <5 µm confirming suitable aerodynamic properties for non-invasive lung delivery. The in-vitro cytotoxicity, and TEER integrity following treatment with the LbL assembled particles in normal lung epithelial and fibroblasts showed no significant cytotoxicity rendering the LbL assembled particles safe. This study extends the efficiency of LbL assembled particles for novel applications towards delivery of small and large molecules into the lungs.


Assuntos
Quitosana , Sistemas de Liberação de Medicamentos , Pulmão , Tamanho da Partícula , Soroalbumina Bovina , Quitosana/química , Soroalbumina Bovina/química , Pulmão/efeitos dos fármacos , Pulmão/metabolismo , Administração por Inalação , Animais , Bovinos , Humanos , Portadores de Fármacos/química , Aerossóis/química , Linhagem Celular
13.
J Chromatogr A ; 1727: 465009, 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-38776605

RESUMO

Previous in vitro toxicological assessments have demonstrated that almost no mutagenic and genotoxic activities in electronic cigarette (e-cigarette) and heated tobacco product (HTP) aerosols were detected even at the maximum recommended concentration. To accurately compare the toxicity levels between cigarette smoke and e-cigarette or HTP aerosols, higher exposure concentrations increasing the possibility to detect toxicity in in vitro tests are necessary, while avoiding solvent-induced toxicity. This study aimed to develop a solvent-free extraction method to obtain concentrated aerosol extracts for improved toxicological evaluation. Our novel approach involved squeezing several Cambridge filter pads, which collected aerosol constituents, in closed containers to achieve solvent-free extraction with comparable efficiency to the conventional method using organic solvents. The optimized squeezing method yielded extracts with concentrations approximately 10 times higher than those obtained in conventional extraction methods. Yield comparison of various constituents, such as flavoring compounds, in e-cigarette aerosol extracts revealed similar extraction efficiencies between the squeezing and conventional methods. However, the extraction efficiency for constituents with high log Pow values, predominantly found in HTP aerosol extracts, was unacceptably low using the squeezing method. In addition, solvent-free centrifuging, another type of extraction method, exhibited unsatisfactory results for even e-cigarette aerosols compared with the conventional method. Our findings suggest that the solvent-free squeezing method is suitable for extracting aerosol collected mass from e-cigarette aerosol but not from HTP aerosol. We anticipate that the solvent-free squeezing method will contribute to a deeper understanding of toxicological differences between e-cigarettes and conventional combustible cigarettes.


Assuntos
Aerossóis , Sistemas Eletrônicos de Liberação de Nicotina , Produtos do Tabaco , Aerossóis/análise , Aerossóis/química , Produtos do Tabaco/análise , Temperatura Alta , Solventes/química , Fracionamento Químico/métodos , Aromatizantes/isolamento & purificação , Aromatizantes/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos
14.
J Phys Chem A ; 128(15): 3015-3023, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38593044

RESUMO

Respiratory viruses, such as influenza and severe acute respiratory syndrome coronavirus 2, represent a substantial public health burden and are largely transmitted through respiratory droplets and aerosols. Environmental factors such as relative humidity (RH) and temperature impact virus transmission rates, and a precise mechanistic understanding of the connection between these environmental factors and virus transmission would improve efforts to mitigate respiratory disease transmission. Previous studies on supermicrometer particles observed RH-dependent phase transitions and linked particle phase state to virus viability. Phase transitions in atmospheric aerosols are dependent on size in the submicrometer range, and actual respiratory particles are expelled over a large size range, including submicrometer aerosols that can transmit diseases over long distances. Here, we directly investigated the phase transitions of submicrometer model respiratory aerosols. A probe molecule, Nile red, was added to particle systems including multiple mucin/salt mixtures, a growth medium, and simulated lung fluid. For each system, the polarity-dependent fluorescence emission was measured following RH conditioning. Notably, the fluorescence measurements of mucin/NaCl and Dulbecco's modified Eagle's medium particles indicated that liquid-liquid phase separation (LLPS) also occurs in submicron particles, suggesting that LLPS can also impact the viability of viruses in submicron particles and thus affect aerosol virus transmission. Furthermore, the utility of fluorescence-based measurements to study submicrometer respiratory particle physicochemical properties in situ is demonstrated.


Assuntos
Mucinas , Aerossóis e Gotículas Respiratórios , Umidade , Aerossóis/química
15.
Environ Int ; 186: 108629, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38582060

RESUMO

Recently, extreme wildfires occur frequently around the world and emit substantial brown carbon (BrC) into the atmosphere, whereas the molecular compositions and photochemical evolution of BrC remain poorly understood. In this work, primary smoke aerosols were generated from wood smoldering, and secondary smoke aerosols were formed by the OH radical photooxidation in an oxidation flow reactor, where both primary and secondary smoke samples were collected on filters. After solvent extraction of filter samples, the molecular composition of dissolved organic carbon (DOC) was determined by Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS). The molecular composition of dissolved BrC was obtained based on the constraints of DOC formulae. The proportion of dissolved BrC fractions accounted for approximately 1/3-1/2 molecular formulae of DOC. The molecular characteristics of dissolved BrC showed higher levels of carbon oxidation state, double bond equivalents, and modified aromaticity index than those of DOC, indicating that dissolved BrC fractions were a class of organic structures with relatively higher oxidation state, unsaturated and aromatic degree in DOC fractions. The comparative analysis suggested that aliphatic and olefinic structures dominated DOC fractions (contributing to 70.1%-76.9%), while olefinic, aromatic, and condensed aromatic structures dominated dissolved BrC fractions (contributing to 97.5%-99.9%). It is worth noting that dissolved BrC fractions only contained carboxylic-rich alicyclic molecules (CRAMs)-like structures, unsaturated hydrocarbons, aromatic structures, and highly oxygenated compounds. CRAMs-like structures were the most abundant species in both DOC and dissolved BrC fractions. Nevertheless, the specific molecular characteristics for DOC and dissolved BrC fractions varied with subgroups after aging. The results highlight the similarities and differences in the molecular compositions and characteristics of DOC and dissolved BrC fractions with aging. This work will provide insights into understanding the molecular composition of DOC and dissolved BrC in smoke.


Assuntos
Aerossóis , Carbono , Fumaça , Madeira , Carbono/análise , Carbono/química , Fumaça/análise , Madeira/química , Aerossóis/análise , Aerossóis/química , Oxirredução , Incêndios Florestais , Poluentes Atmosféricos/análise , Poluentes Atmosféricos/química , Processos Fotoquímicos
16.
Carbohydr Polym ; 336: 122133, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38670771

RESUMO

Using respiratory protective equipment is one of the relevant preventive measures for infectious diseases, including COVID-19, and for various occupational respiratory hazards. Because experienced discomfort may result in a decrease in the utilization of respirators, it is important to enhance the material properties to resolve suboptimal usage. We combined several technologies to produce a filtration material that met requirements set by a cross-disciplinary interview study on the usability of protective equipment. Improved breathability, environmental sustainability, and comfort of the material were achieved by electrospinning poly(ethylene oxide) (PEO) nanofibers on a thin foam-formed fabric from regenerated cellulose fibers. The high filtration efficiency of sub-micron-sized diethylhexyl sebacate (DEHS) aerosol particles resulted from the small mean segment length of 0.35 µm of the nanofiber network. For a particle diameter of 0.6 µm, the filtration efficiency of a single PEO layer varied in the range of 80-97 % depending on the coat weight. The corresponding pressure drop had the level of 20-90 Pa for the airflow velocity of 5.3 cm/s. Using a multilayer structure, a very high filtration efficiency of 99.5 % was obtained with only a slightly higher pressure drop. This opens a route toward designing sustainable personal protective media with improved user experience.


Assuntos
Celulose , Filtração , Nanofibras , Celulose/química , Celulose/análogos & derivados , Filtração/métodos , Nanofibras/química , Humanos , COVID-19/prevenção & controle , Polietilenoglicóis/química , Dispositivos de Proteção Respiratória , Tamanho da Partícula , SARS-CoV-2 , Aerossóis/química
17.
Environ Sci Technol ; 58(18): 7904-7915, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38661303

RESUMO

Nitrogen dioxide (NO2) hydrolysis in deliquesced aerosol particles forms nitrous acid and nitrate and thus impacts air quality, climate, and the nitrogen cycle. Traditionally, it is considered to proceed far too slowly in the atmosphere. However, the significance of this process is highly uncertain because kinetic studies have only been made in dilute aqueous solutions but not under high ionic strength conditions of the aerosol particles. Here, we use laboratory experiments, air quality models, and field measurements to examine the effect of the ionic strength on the reaction kinetics of NO2 hydrolysis. We find that high ionic strengths (I) enhance the reaction rate constants (kI) by more than an order of magnitude compared to that at infinite dilution (kI=0), yielding log10(kI/kI=0) = 0.04I or rate enhancement factor = 100.04I. A state-of-the-art air quality model shows that the enhanced NO2 hydrolysis reduces the negative bias in the simulated concentrations of nitrous acid by 28% on average when compared to field observations over the North China Plain. Rapid NO2 hydrolysis also enhances the levels of nitrous acid in other polluted regions such as North India and further promotes atmospheric oxidation capacity. This study highlights the need to evaluate various reaction kinetics of atmospheric aerosols with high ionic strengths.


Assuntos
Aerossóis , Aerossóis/química , Hidrólise , Concentração Osmolar , Dióxido de Nitrogênio/química , Cinética , Atmosfera/química , Poluentes Atmosféricos/química
18.
ACS Nano ; 18(17): 11335-11348, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38621181

RESUMO

Leveraging the extensive surface area of the lungs for gene therapy, the inhalation route offers distinct advantages for delivery. Clinical nebulizers that employ vibrating mesh technology are the standard choice for converting liquid medicines into aerosols. However, they have limitations when it comes to delivering mRNA through inhalation, including severe damage to nanoparticles due to shearing forces. Here, we introduce a microfluidic aerosolization platform (MAP) that preserves the structural and physicochemical integrity of lipid nanoparticles, enabling safe and efficient delivery of mRNA to the respiratory system. Our results demonstrated the superiority of the MAP over the conventional vibrating mesh nebulizer, as it avoided problems such as particle aggregation, loss of mRNA encapsulation, and deformation of the nanoparticle morphology. Notably, aerosolized nanoparticles generated by the microfluidic device led to enhanced transfection efficiency across various cell lines. In vivo experiments with mice that inhaled these aerosolized nanoparticles revealed successful lung-specific mRNA transfection without observable signs of toxicity. This MAP may represent an advancement for the pulmonary gene therapy, enabling precise and effective delivery of aerosolized nanoparticles.


Assuntos
Aerossóis , Lipossomos , Nanopartículas , RNA Mensageiro , Nanopartículas/química , Animais , RNA Mensageiro/genética , RNA Mensageiro/administração & dosagem , Aerossóis/química , Camundongos , Administração por Inalação , Humanos , Lipídeos/química , Microfluídica/métodos , Tamanho da Partícula , Dispositivos Lab-On-A-Chip
19.
Int J Pharm ; 654: 123984, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38461874

RESUMO

Both latent and multidrug-resistant tuberculosis (TB) have been causing significant concern worldwide. A novel drug, pretomanid (PA-824), has shown a potent bactericidal effect against both active and latent forms of Mycobacterium tuberculosis (MTb) and a synergistic effect when combined with pyrazinamide and moxifloxacin. This study aimed to develop triple combination spray dried inhalable formulations composed of antitubercular drugs, pretomanid, moxifloxacin, and pyrazinamide (1:2:8 w/w/w), alone (PaMP) and in combination with an aerosolization enhancer, L-leucine (20 % w/w, PaMPL). The formulation PaMPL consisted of hollow, spherical, dimpled particles (<5 µm) and showed good aerosolization behaviour with a fine particle fraction of 70 %. Solid-state characterization of formulations with and without L-leucine confirmed the amorphous nature of moxifloxacin and pretomanid and the crystalline nature of pyrazinamide with polymorphic transformation after the spray drying process. Further, the X-ray photoelectron spectroscopic analysis revealed the predominant surface composition of L-leucine on PaMPL dry powder particles. The dose-response cytotoxicity results showed pyrazinamide and moxifloxacin were non-toxic in both A549 and Calu-3 cell lines up to 150 µg/mL. However, the cell viability gradually decreased to 50 % when the pretomanid concentration increased to 150 µg/mL. The in vitro efficacy studies demonstrated that the triple combination formulation had more prominent antibacterial activity with a minimum inhibitory concentration (MIC) of 1 µg/mL against the MTb H37Rv strain as compared to individual drugs. In conclusion, the triple combination of pretomanid, moxifloxacin, and pyrazinamide as an inhalable dry powder formulation will potentially improve treatment efficacy with fewer systemic side effects in patients suffering from latent and multidrug-resistant TB.


Assuntos
Nitroimidazóis , Pirazinamida , Tuberculose Resistente a Múltiplos Medicamentos , Humanos , Pirazinamida/farmacologia , Pirazinamida/química , Moxifloxacina/farmacologia , Moxifloxacina/química , Pós/química , Leucina/química , Aerossóis/química , Antituberculosos/farmacologia , Antituberculosos/química , Tuberculose Resistente a Múltiplos Medicamentos/tratamento farmacológico , Administração por Inalação , Inaladores de Pó Seco/métodos , Tamanho da Partícula
20.
J Chromatogr A ; 1720: 464777, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38432108

RESUMO

The majority of commercially available monoclonal antibody (mAb) formulations are stabilized with one of three non-ionic surfactants: polysorbate 20 (PS20), polysorbate 80 (PS80), or poloxamer 188 (P188). All three surfactants are susceptible to degradation, which can result in functionality loss and subsequent protein aggregation or free fatty acid particle formation. Consequently, quantitative, and qualitative analysis of surfactants is an integral part of formulation development, stability, and batch release testing. Due to the heterogeneous nature of both polysorbates and poloxamer, online isolation of all the compounds from the protein and other excipients that may disturb the subsequent liquid chromatography with charged aerosol detection (LC-CAD) analysis poses a challenge. Herein, we present an analytical method employing LC-CAD, utilizing a combination of anion and cation exchange columns to completely remove proteins online before infusing the isolated surfactant onto a reversed-phase column. The method allows high throughput analysis of polysorbates within 8 minutes and poloxamer 188 within 12 minutes, providing a separation of the surfactant species of polysorbates (unesterified species, lower esters, and higher esters) and poloxamer 188 (early eluters and main species). Accuracy and precision assessed according to the International Council for harmonisation (ICH) guideline were 96 - 109 % and ≤1 % relative standard deviation respectively for all three surfactants in samples containing up to 110 mg/mL mAb. Subsequently, the method was effectively applied to quantify polysorbate 20 and polysorbate 80 in nine commercial drug products with mAb concentration of up to 180 mg/mL.


Assuntos
Poloxâmero , Polissorbatos , Polissorbatos/química , Poloxâmero/análise , Anticorpos Monoclonais/química , Tensoativos/química , Cromatografia Líquida , Aerossóis/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...