Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.181
Filtrar
1.
Curr Opin Anaesthesiol ; 37(4): 362-370, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38841991

RESUMO

PURPOSE OF REVIEW: The drug titration paradox describes that, from a population standpoint, drug doses appear to have a negative correlation with its clinical effect. This paradox is a relatively modern discovery in anesthetic pharmacology derived from large clinical data sets. This review will interpret the paradox using a control engineering perspective. RECENT FINDINGS: Drug titration is a challenging endeavor, and the medication delivery systems used in everyday clinical practice, including infusion pumps and vaporizers, typically do not allow for rapid or robust titration of medication being delivered. In addition, clinicians may be reluctant to deviate from a predetermined plan or may be content to manage patients within fixed goal boundaries. SUMMARY: This drug titration paradox describes the constraints of how the average clinician will dose a patient with an unknown clinical response. While our understanding of the paradox is still in its infancy, it remains unclear how alternative dosing schemes, such as through automation, may exceed the boundaries of the paradox and potentially affect its conclusions.


Assuntos
Anestésicos , Humanos , Anestésicos/administração & dosagem , Sistemas de Liberação de Medicamentos/métodos , Relação Dose-Resposta a Droga , Bombas de Infusão/normas
2.
Curr Opin Anaesthesiol ; 37(4): 379-383, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38842001

RESUMO

PURPOSE OF REVIEW: The environmental impact of anesthesia far exceeds that of other medical specialties due to our use of inhaled anesthetic agents (which are potent greenhouse gases) and many intravenous medications. RECENT FINDINGS: Calls for reducing the carbon footprint of anesthesia are ubiquitous in the anesthesia societies of developed nations and are appearing in proposed changes for hospital accreditation and funding in the United States. The body of research on atmospheric, land and water impacts of anesthetic pharmaceuticals is growing and generally reinforces existing recommendations to reduce the greenhouse gas emissions of anesthesia care. SUMMARY: The environmental impact of anesthesia care should factor into our clinical decisions. The onus is on clinicians to safely care for our patients in ways that contribute the least harm to the environment. Intravenous anesthesia and regional techniques have less environmental impact than the use of inhaled agents; efforts to reduce and properly dispose of pharmaceutical waste are central to reducing environmental burden; desflurane should not be used; nitrous oxide should be avoided except where clinically necessary; central nitrous pipelines should be abandoned; low fresh gas flows should be utilized whenever inhaled agents are used.


Assuntos
Anestésicos Inalatórios , Humanos , Anestésicos Inalatórios/efeitos adversos , Anestésicos Inalatórios/administração & dosagem , Anestésicos/efeitos adversos , Anestésicos/administração & dosagem , Pegada de Carbono , Meio Ambiente , Gases de Efeito Estufa/efeitos adversos , Gases de Efeito Estufa/análise
3.
J Zoo Wildl Med ; 55(2): 466-470, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38875204

RESUMO

Black-handed spider monkeys (Ateles geoffroyi ssp.) are endangered in Mexico. Safe anesthetic protocols are important for in situ and ex situ conservation problems. Such protocols are scarce in the literature; nor have safety and physiologic responses been reported. High doses and volume are a counter side for field immobilizations. We tested an anesthetic protocol with a combination of tiletamine-zolazepam (5 mg/kg) plus xylazine (1 mg/kg) in 14 black-handed spider monkeys under human care from two facilities in Mexico. Physiological parameters such as HR, RR, T, SPO2, systolic arterial pressure (), diastolic arterial pressure (DAP), and median arterial pressure (MAP) were obtained. HR and RR decreased over time, but T increased significantly during the anesthetic time for the whole group; RR and T decreased for juveniles only. Variation between individuals was observed for HR, RR, and DAP. Volume reduction of drugs was achieved compared to previously reported anesthesia protocols. Induction time was fast (6.2 ± 10.4 min) and no tail prehension was seen. Recovery was prolonged (mean and SD). Physiologic parameters remained stable throughout. The protocol proved to be safe for the chemical immobilization of black-handed spider monkeys.


Assuntos
Ateles geoffroyi , Tiletamina , Xilazina , Zolazepam , Animais , Tiletamina/administração & dosagem , Tiletamina/farmacologia , Zolazepam/administração & dosagem , Zolazepam/farmacologia , Xilazina/farmacologia , Xilazina/administração & dosagem , Masculino , Feminino , Combinação de Medicamentos , Anestesia/veterinária , Hipnóticos e Sedativos/farmacologia , Hipnóticos e Sedativos/administração & dosagem , Anestésicos/farmacologia , Anestésicos/administração & dosagem , Anestésicos Combinados/administração & dosagem , Anestésicos Combinados/farmacologia
4.
Vet Med Sci ; 10(4): e1492, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38879883

RESUMO

BACKGROUND: Using anaesthetics is an important application in aquaculture especially where the fish transportation, vaccination, grading, sorting activities and many other handling operations have been conducted during the different stages of production periods in the farms or hatcheries. OBJECTIVES: This study aimed to evaluate the efficacy of oregano essential oil (OO) as an anaesthetic for Nile tilapia and to determine the optimal concentration and post-application stress effects compared to clove oil (CO). METHODS: Nile tilapia juveniles were exposed to different concentrations of OO (20-40-60-80-100 mg L-1) and CO (50 mg L-1) for different time periods to determine the optimal concentration and exposure time. After the effective concentration of OO was determined, in the second experiment, stress parameters (glucose, plasma cortisol) were analysed after 0, 2, 6, 12 and 24 h of application. The results compared to the control group and CO results. RESULTS: The study found that OO which has carvacrol compound higher than 78% was an efficient anaesthetic for Nile tilapia, and the effective concentration was found to be 60 mg L-1. No significant differences were found between opercular beats in any concentration of OO and CO. Basal glucose level in blood without anaesthesia application and recorded at 39.33 mg dL-1 and significantly lower than OO and CO at first two sampling points, 0 and 2 h (p < 0.05). According to plasma cortisol level results, although CO experimental group showed secondary stress response at 12 h (17.91 ± 4.21 ng mL-1), OO and CO group cortisol levels decreased at 24 h after anaesthesia application 7.13 ± 0.14and 7.01 ± 0.54 ng mL-1, respectively, below the control group cortisol concentration (12.28 ± 1.81 ng mL-1). CONCLUSIONS: These findings have important implications for the aquaculture industry as the use of OO as an anaesthetic could reduce the stress and mortality associated with traditional anaesthetics. Further research is needed to evaluate the efficacy of OO as an anaesthetic agent for other fish species and to determine the optimal concentration and exposure time for different species.


Assuntos
Anestésicos , Ciclídeos , Óleos Voláteis , Origanum , Estresse Fisiológico , Animais , Ciclídeos/fisiologia , Anestésicos/farmacologia , Anestésicos/administração & dosagem , Origanum/química , Estresse Fisiológico/efeitos dos fármacos , Óleos Voláteis/farmacologia , Óleos Voláteis/administração & dosagem , Óleo de Cravo/farmacologia , Óleos de Plantas/farmacologia , Óleos de Plantas/química , Relação Dose-Resposta a Droga , Hidrocortisona/sangue , Aquicultura
5.
Lab Anim ; 58(3): 277-280, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38779993

RESUMO

Melatonin (ML) and dexmedetomidine (DM) are used separately as anesthetic premedication or as an anesthetic in humans and laboratory animals. In this study, we aimed to investigate the anesthetic properties of both drugs combined. The anesthetic effects of several combinations of ML (50 and 100 mg/kg) and DM (50 and 100 µg/kg) were evaluated in rats by observing behavioral manifestations and recording the duration and depth of anesthesia. Five anesthetic intervals were established according to the loss and recovery of reflexes. While each individual drug did not induce an appropriate anesthetic effect at the tested doses, ML50 + DM100, ML100 + DM50 and ML100 + DM100 combinations resulted in surgical anesthesia intervals of 60 to 360 min. Together, our results point that the use of ML allows to decrease the dose of DM, reducing the unwanted anesthetic effects of this α2-agonist.


Assuntos
Anestesia , Dexmedetomidina , Melatonina , Dexmedetomidina/administração & dosagem , Dexmedetomidina/farmacologia , Animais , Melatonina/administração & dosagem , Melatonina/farmacologia , Ratos , Masculino , Anestesia/métodos , Ratos Wistar , Hipnóticos e Sedativos/administração & dosagem , Hipnóticos e Sedativos/farmacologia , Anestésicos/administração & dosagem , Anestésicos/farmacologia
6.
J Clin Anesth ; 95: 111473, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38613937

RESUMO

Use of herbal medications and supplements has experienced immense growth over the last two decades, with retail sales in the USA exceeding $13 billion in 2021. Since the Dietary Supplement Health and Education Act (DSHEA) of 1994 reduced FDA oversight, these products have become less regulated. Data from 2012 shows 18% of U.S. adults used non-vitamin, non-mineral natural products. Prevalence varies regionally, with higher use in Western states. Among preoperative patients, the most commonly used herbal medications included garlic, ginseng, ginkgo, St. John's wort, and echinacea. However, 50-70% of surgical patients fail to disclose their use of herbal medications to their physicians, and most fail to discontinue them preoperatively. Since herbal medications can interact with anesthetic medications administered during surgery, the American Society of Anesthesiologists (ASA) and the American Association of Nurse Anesthetists (AANA) recommend stopping herbal medications 1-2 weeks before elective surgical procedures. Potential adverse drug effects related to preoperative use of herbal medications involve the coagulation system (e.g., increasing the risk of perioperative bleeding), the cardiovascular system (e.g., arrhythmias, hypotension, hypertension), the central nervous system (e.g., sedation, confusion, seizures), pulmonary (e.g., coughing, bronchospasm), renal (e.g., diuresis) and endocrine-metabolic (e.g., hepatic dysfunction, altered metabolism of anesthetic drugs). During the preoperative evaluation, anesthesiologists should inquire about the use of herbal medications to anticipate potential adverse drug interactions during the perioperative period.


Assuntos
Interações Ervas-Drogas , Preparações de Plantas , Humanos , Preparações de Plantas/efeitos adversos , Preparações de Plantas/administração & dosagem , Período Perioperatório , Suplementos Nutricionais/efeitos adversos , Assistência Perioperatória/métodos , Anestésicos/efeitos adversos , Anestésicos/administração & dosagem , Fitoterapia/efeitos adversos , Estados Unidos , Interações Medicamentosas
7.
Ann Pharm Fr ; 82(4): 706-717, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38447875

RESUMO

INTRODUCTION: In anesthesia, a medication error would occur every 20 to 133 anesthesia procedures, and 14% is related to a route administration error. To secure neuraxial route, ISO group published a norm in 2016 to develop specific connectors, the "NRFit® connector". The main objective of this work, is to develop a risk mapping related to neuraxial medication errors therefore prepare the NRFit® implementation in anesthesia units in a French Universitary Hospital. METHODS: Failure modes, effects and criticality analysis (FMECA) methodology was used for our risk mapping which was divided in 3 anesthesia specialities. For each, the analysis was performed for accidental neuraxial administration of intravenous drugs, and its opposite error. Secondly, NRFit® devices were tested for 1 month by 3 experimented anesthetists. RESULTS: The majority of reported errors concerns epidural and intrathecal anesthesia, and more frequently in the field of obstetrics. Opioids and tranexamic acid, administered in neuraxial route, are drugs with the highest criticality. The tests were rather conclusive and made it possible to highlight the additional needs in medical devices. DISCUSSION: Obstetrics is the riskiest area due to the frequency of epidural anesthesia, the administration of critical drugs in intravenous and neuraxial route. This work increased the awareness of our group, improved the measure of this risk and harmonized practices. CONCLUSION: This work is the first step of the project to prevent administration route error in anesthesia during patient's drug management. The next step will be the NRFit® implementation for epidural and combined spinal-epidural anesthesia in our hospital.


Assuntos
Erros de Medicação , Humanos , Erros de Medicação/prevenção & controle , Anestesia Epidural/instrumentação , Raquianestesia/instrumentação , França , Anestésicos/administração & dosagem , Medição de Risco , Anestesia Obstétrica/instrumentação , Anestesia , Feminino
8.
Comp Med ; 74(2): 81-91, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38514175

RESUMO

Plethysmography is employed in nonhuman primates (NHPs) to calculate respiratory minute volume and determine the exposure time required to deliver an aerosol at the target dose. Anesthetic drugs can impact breathing parameters like steady-state minute volume (SSMV) central to aerosol dosing. Alfaxalone-midazolam mixtures (AM) provide superior parameters for plethysmography in cynomolgus macaques. An obstacle to the use of AM is the volume required to anesthetize via intramuscular injection. A more concentrated formulation of alfaxalone will reduce injection volumes and refine AM protocols. The purpose of this study was to compare AM using the Indexed 10-mg/mL (AM10) formulation compared with an investigational 40-mg/mL (AM40) formulation for IM administration in cynomolgus macaques undergoing plethysmography. We hypothesized that AM10 and AM40 would show no difference in quality of anesthesia (QA), duration of anesthesia, SSMV, accumulated minute volume (AMV), and side effects. We also hypothesized that female macaques would have a longer duration of anesthesia compared with males using both formulations. The study used 15 cynomolgus macaques comprised of 8 females and 7 males. NHPs were compared between 2 separate and randomized anesthetic events no less than one week apart. Each animal served as its own control and animals were randomized by random number generation. Anesthetized NHPs were placed in a sealed plethysmography chamber, and minute volume measurements were calculated every 10 s to determine SSMV. Once SSMV was achieved for 20 min, the trial ended. There were no statistically significant differences between AM10 and AM40 for duration of anesthesia, SSMV, AMV, side effects, or QA. AM40 had a significantly smaller injection volume. Females did not show a significantly longer median duration of anesthesia using either of the alfaxalone formulations. Overall, AM40 offers a more humane anesthetic than AM10 for plethysmography in cynomolgus macaques.


Assuntos
Macaca fascicularis , Midazolam , Pletismografia , Pregnanodionas , Animais , Pregnanodionas/administração & dosagem , Pregnanodionas/farmacologia , Midazolam/administração & dosagem , Midazolam/farmacologia , Feminino , Masculino , Injeções Intramusculares , Anestésicos/administração & dosagem , Anestésicos/farmacologia , Anestesia/veterinária , Anestésicos Combinados/administração & dosagem , Anestésicos Combinados/farmacologia
9.
Curr Opin Anaesthesiol ; 37(3): 285-291, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38390901

RESUMO

PURPOSE OF REVIEW: Nonobstetric surgery during pregnancy is associated with maternal and fetal risks. Several physiologic changes create unique challenges for anesthesiologists. This review highlights physiologic changes of pregnancy and presents clinical recommendations based on recent literature to guide anesthetic management for the pregnant patient undergoing nonobstetric surgery. RECENT FINDINGS: Nearly every anesthetic technique has been safely used in pregnant patients. Although it is difficult to eliminate confounding factors, exposure to anesthetics could endanger fetal brain development. Perioperative fetal monitoring decisions require an obstetric consult based on anticipated maternal and fetal concerns. Given the limitations of fasting guidelines, bedside gastric ultrasound is useful in assessing aspiration risk in pregnant patients. Although there is concern about appropriateness of sugammadex for neuromuscular blockade reversal due its binding to progesterone, preliminary literature supports its safety. SUMMARY: These recommendations will equip anesthesiologists to provide safe care for the pregnant patient and fetus undergoing nonobstetric surgery.


Assuntos
Anestesia , Feto , Humanos , Gravidez , Feminino , Anestesia/métodos , Anestesia/efeitos adversos , Anestesia/normas , Feto/efeitos dos fármacos , Feto/cirurgia , Anestésicos/efeitos adversos , Anestésicos/administração & dosagem , Monitorização Fetal/métodos , Monitorização Fetal/normas , Complicações na Gravidez/prevenção & controle , Guias de Prática Clínica como Assunto , Procedimentos Cirúrgicos Operatórios/efeitos adversos , Anestesia Obstétrica/métodos , Anestesia Obstétrica/efeitos adversos , Anestesia Obstétrica/normas
10.
Korean J Anesthesiol ; 77(3): 289-305, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38228393

RESUMO

Intraoperative electroencephalography (EEG) monitoring under pediatric anesthesia has begun to attract increasing interest, driven by the availability of pediatric-specific EEG monitors and the realization that traditional dosing methods based on patient movement or changes in hemodynamic response often lead to imprecise dosing, especially in younger infants who may experience adverse events (e.g., hypotension) due to excess anesthesia. EEG directly measures the effects of anesthetics on the brain, which is the target end-organ responsible for inducing loss of consciousness. Over the past ten years, research on anesthesia and computational neuroscience has improved our understanding of intraoperative pediatric EEG monitoring and expanded the utility of EEG in clinical practice. We now have better insights into neurodevelopmental changes in the developing pediatric brain, functional connectivity, the use of non-proprietary EEG parameters to guide anesthetic dosing, epileptiform EEG changes during induction, EEG changes from spinal/regional anesthesia, EEG discontinuity, and the use of EEG to improve clinical outcomes. This review article summarizes the recent literature on EEG monitoring in perioperative pediatric anesthesia, highlighting several of the topics mentioned above.


Assuntos
Eletroencefalografia , Humanos , Eletroencefalografia/métodos , Eletroencefalografia/efeitos dos fármacos , Criança , Monitorização Intraoperatória/métodos , Lactente , Monitorização Neurofisiológica Intraoperatória/métodos , Anestesia/métodos , Anestésicos/administração & dosagem , Anestésicos/efeitos adversos , Pré-Escolar
12.
Vet Anaesth Analg ; 50(6): 502-506, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37806870

RESUMO

OBJECTIVE: To evaluate the accuracy with which veterinary anaesthetists and nurses of different experience draw up small volumes of liquid. STUDY DESIGN: Prospective blinded randomized study. METHODS: A group of seven European College of Veterinary Anaesthesia and Analgesia (ECVAA) diplomates, six ECVAA residents and six anaesthesia nurses participated in the study. For each participant, five target volumes between 0.01 and 1.0 mL were randomly allocated. They were drawn up 20 times in random order using a 1 mL syringe attached to a 23 gauge needle. A total of 1900 measurements were analysed. An investigator filled the syringe and needle dead space with water for injection before each experiment. The change in mass of the syringe once filled to the target volume was used to calculate the actual volume of liquid drawn up. RESULTS: Large errors were made with measurements < 0.04 mL, so they were excluded from the statistical analysis. There was a significant effect of the target volume (p < 0.001) and of the order (p < 0.01). For each mL increase in the target volume, the absolute error decreased by 4% and from the first to the hundredth withdrawal each participant's absolute error decreased by 1%. The target volume was underestimated in 52.3% of measurements, 42% were overestimated and 5.7% were on target. None of the between-subject predictor variables approached significance. CONCLUSIONS AND CLINICAL RELEVANCE: Accuracy of veterinary anaesthetists and nurses in drawing up medications decreases as the target volume becomes smaller. Small veterinary patients receive small volumes of anaesthetic drugs with higher risks of overdosing compared with larger dogs. Years of experience and staff grade are not associated with greater accuracy. Large percentage errors may be seen with target volumes less than 0.04 mL. Dilutions are recommended for volumes > 0.19 mL in 1 mL syringe.


Assuntos
Anestesia , Anestésicos , Animais , Cães , Humanos , Anestésicos/administração & dosagem , Anestesistas/estatística & dados numéricos , Injeções/estatística & dados numéricos , Injeções/veterinária , Estudos Prospectivos , Enfermeiros Anestesistas/estatística & dados numéricos , Anestesia/métodos , Anestesia/estatística & dados numéricos , Anestesia/veterinária
13.
Int J Obstet Anesth ; 54: 103650, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36934515

RESUMO

Accidental awareness under general anaesthesia (AAGA) remains a major complication of anaesthesia. The incidence of AAGA during obstetric anaesthesia is high relative to other specialities. The use of processed electroencephalography (pEEG) in the form of "depth of anaesthesia" monitoring has been shown to reduce the incidence of AAGA in the non-obstetric population. The evidence for using pEEG to prevent AAGA in the obstetric population is poor and requires further exploration. Furthermore, pregnancy and disease states affecting the central nervous system, such as pre-eclampsia, may alter the interpretation of pEEG waveforms although this has not been fully characterised. National guidelines exist for pEEG monitoring with total intravenous anaesthesia and for "high-risk" cases regardless of technique, including the obstetric population. However, none of the currently available guidelines relates specifically to obstetric anaesthesia. Using pEEG monitoring for obstetric anaesthesia may also provide additional benefits beyond a reduction in risk of AAGA. These potential benefits include reduced postoperative nausea and vomiting, reduced anaesthetic agent use, and a shorter post-anaesthetic recovery stay. In addition, pEEG acts as a surrogate marker of cerebral perfusion, and thus as an additional monitor for impending cardiovascular collapse, as seen in amniotic fluid embolism. The subtle physiological and pathological changes in EEG activity that may occur during pregnancy are an unexplored research area in the context of anaesthetic pEEG monitors. We believe that the direction of clinical practice is moving towards greater use of pEEG monitoring and individualisation of anaesthesia.


Assuntos
Anestesia Geral , Anestesia Obstétrica , Anestésicos , Eletroencefalografia , Consciência no Peroperatório , Feminino , Humanos , Gravidez , Anestesiologia , Anestésicos/administração & dosagem , Consciência no Peroperatório/epidemiologia , Incidência
14.
Oncol Rep ; 49(2)2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36562401

RESUMO

Prometastatic and antitumor effects of different anesthetics have been previously analyzed in several studies with conflicting results. Thus, the underlying perioperative molecular mechanisms mediated by anesthetics potentially affecting tumor phenotype and metastasis remain unclear. It was hypothesized that anesthetic­specific long non­coding RNA (lncRNA) expression changes are induced in the blood circulation and play a crucial role in tumor outcome. In the present study, high­throughput sequencing and quantitative PCR were performed in order to identify lncRNA and mRNA expression changes affected by two therapeutic regimes, total intravenous anesthesia (TIVA) and volatile anesthetic gas (VAG) in patients undergoing colorectal cancer (CRC) resection. Total blood RNA was isolated prior to and following resection and characterized using RNA sequencing. mRNA­lncRNA interactions and their roles in cancer­related signaling of differentially expressed lncRNAs were identified using bioinformatics analyses. The comparison of these two time points revealed 35 differentially expressed lncRNAs in the TIVA­group, and 25 in the VAG­group, whereas eight were shared by both groups. Two lncRNAs in the TIVA­group, and 23 in the VAG­group of in silico identified target­mRNAs were confirmed as differentially regulated in the NGS dataset of the present study. Pathway analysis was performed and cancer relevant canonical pathways for TIVA were identified. Target­mRNA analysis of VAG revealed a markedly worsened immunological response against cancer. In this proof­of­concept study, anesthesic­specific expression changes in lncRNA and mRNA profiles in blood were successfully identified. Moreover, the data of the present study provide the first evidence that anesthesia­induced lncRNA pattern changes may contribute further in the observed differences in CRC outcome following tumor resection.


Assuntos
Anestésicos , Neoplasias Colorretais , RNA Longo não Codificante , Humanos , Anestésicos/administração & dosagem , Anestésicos/farmacologia , Neoplasias Colorretais/sangue , Neoplasias Colorretais/tratamento farmacológico , Perfilação da Expressão Gênica/métodos , Regulação Neoplásica da Expressão Gênica , Redes Reguladoras de Genes , Projetos Piloto , Estudos Prospectivos , RNA Longo não Codificante/sangue , RNA Longo não Codificante/metabolismo , RNA Mensageiro/sangue , RNA Mensageiro/metabolismo , Administração Intravenosa
15.
Adv Anesth ; 41(1): 53-69, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-38251622

RESUMO

The prevalence of cardiac disease-related maternal morbidity and mortality is on the rise in the United States. To ensure safe management of pregnancy in patients with cardiovascular disease, pre-delivery evaluation by a multidisciplinary Pregnancy Heart Team should occur. Appropriate anesthetic, cardiac, and obstetric care are essential. Risk stratification tools evaluate the etiology and severity of cardiovascular disease to determine the appropriate hospital type and location for delivery and anesthetic management. Intrapartum hemodynamic monitoring may need to be intensified, and neuraxial analgesia and anesthesia are generally appropriate. The anesthesiologist must be prepared for obstetric and cardiac emergencies.


Assuntos
Anestésicos , Cardiopatias , Complicações Cardiovasculares na Gravidez , Feminino , Humanos , Gravidez , Anestésicos/administração & dosagem , Coração , Cardiopatias/diagnóstico , Cardiopatias/terapia , Analgesia Obstétrica/métodos , Complicações Cardiovasculares na Gravidez/diagnóstico , Complicações Cardiovasculares na Gravidez/terapia
17.
Int. j. morphol ; 40(3): 627-631, jun. 2022. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1385652

RESUMO

SUMMARY: The goal of ultrasound-guided suprainguinal fascia iliaca block (USG-SFIB) is anesthetic spread to three nerves, which are lateral femoral cutaneous nerve (LFCN), femoral nerve (FN), and obturator nerve (ON). The 90 % minimum effective volume (MEV90) for USG-SFIB is each result of studied showed the successful block and effect in various volume for block. So, Thus, the study purposes to demonstrate the efficiency of the effective volume (MEV90,62.5 ml) for USG-SFIB and confirm the staining of dye in connective tissue of nerve (nerve layer) that focused on the obturator nerve by histological examination in cadavers. The histological result showed the dye staining on the nerve layer of the ON in epineurium (100 %) and un-staining perineurium & endoneurium. Therefore, the minimal effective volume (MEV) is effective for USG-SFIB. Moreover, dye stain at the epineurium of stained obturator nerve only.


RESUMEN: El objetivo del bloqueo de la fascia ilíaca suprainguinal guiado por ecografía (USG-SFIB) es la propagación anestésica a tres nervios, cutáneo femoral lateral, femoral y obturador. El volumen efectivo mínimo del 90 % (MEV90) para USG-SFIB en cada uno de los resultados mostró el bloqueo exitoso y el efecto en varios volúmenes por bloqueo. Por lo tanto, el estudio tuvo como objetivo demostrar la eficiencia del volumen efectivo (MEV90,62.5 ml) para USG-SFIB y confirmar la tinción de tinte en el tejido conectivo del nervio, el cual se centró en el nervio obturador a través del examen histológico en cadáveres. El resultado histológico mostró tinción de colorante en el epineuro (100 %) del nervio obturador, sin embargo no hubo tinción del perineuro y endoneuro. Por lo tanto, el volumen efectivo mínimo (MEV) es efectivo para USG-SFIB.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Fáscia/efeitos dos fármacos , Anestésicos/administração & dosagem , Bloqueio Nervoso , Cadáver
19.
Braz. J. Vet. Res. Anim. Sci. (Online) ; 59: e188652, fev. 2022. tab
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1363174

RESUMO

Sedative and antinociceptive effects of two anesthetic protocols in black-tufted marmosets were compared in this study. Twenty-six marmosets underwent chemical immobilization for physical examination, blood sampling, tattooing, and microchipping. Animals were randomly treated with S-(+)-ketamine (10 mg/kg) and midazolam (1 mg/kg) (KM) or fentanyl (12.5 µg/kg) and droperidol (625 µg/kg) (FD) given by intramuscular injection. Heart and respiratory rates were recorded. Sedation, antinociception, muscle relaxation, posture, auditory, and visual responses were evaluated using a scoring system. Sedation in KM was achieved faster (p < 0.001) and lasted for a shorter period of time (p = 0.0009). KM was similar to FD in its cardiorespiratory effects, auditory and visual responses. Both protocols promoted adequate sedation to allow manipulation. Animals in KM assumed lateral recumbency while animals in FD maintained a quadrupedal posture during evaluation. FD produced less intense sedation and muscle relaxation but a higher degree of antinociception compared to KM and is suitable for procedures that require analgesia in black-tufted marmosets.(AU)


O presente estudo comparou os efeitos cardiorrespiratórios, sedativos e antinociceptivos de dois protocolos anestésicos em saguis-de-tufo-preto (Callithrix penicillata). Vinte e seis saguis foram submetidos à contenção química para exame físico, coleta de sangue, tatuagem de identificação e microchip. Os animais foram tratados aleatoriamente com a associação de S-(+)-cetamina (10 mg/kg) e midazolam (1 mg/kg) (KM) ou fentanil (12,5 µg/kg) e droperidol (625 µg/kg) (FD), administrados por injeção intramuscular. Foram avaliadas frequência cardíaca, frequência respiratória, sedação, antinocicepção, relaxamento muscular, postura e resposta ao estímulo auditivo e visual. A sedação em KM foi alcançada mais rapidamente (p <0,001) e teve um tempo hábil mais curto (p = 0,0009). KM foi semelhante a FD nos efeitos cardiorrespiratórios, respostas auditivas e visuais. Os dois protocolos promoveram sedação adequada para manipulação. Os animais do grupo KM permaneceram em decúbito lateral durante a avaliação, enquanto os animais em FD mantiveram postura quadrupedal. FD resultou em sedação e relaxamento muscular de menor intensidade, porém com maior escore de antinocicepção em comparação com KM, sendo adequada para procedimentos que requerem analgesia em saguis-de-tufo-preto.(AU)


Assuntos
Animais , Midazolam/administração & dosagem , Callithrix , Fentanila , Droperidol/administração & dosagem , Ketamina/administração & dosagem , Anestésicos/administração & dosagem , Injeções Intramusculares
20.
Medicine (Baltimore) ; 101(1): e28483, 2022 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-35029899

RESUMO

INTRODUCTION: Osteogenesis imperfecta (OI), a rare congenital disorder, has a risk of bone fracture and progressive bone deformity. OI type II is the most serious subtype, and very few reports on its anesthetic management exist. Patients face several anesthetic difficulties, of which easy fracturing of OI-affected bones is critical. Herein, we report our experience with the anesthetic management of a patient with OI type II. PATIENT CONCERNS AND DIAGNOSES: Through genetic testing, a 14-month-old girl (height: 45 cm, weight: 3.9 kg) was diagnosed with OI type IIB due to COL1A gene abnormality. The clinical manifestations included hydrocephalus, blue sclera, dental dysplasia, short stature, limb deformity and shortening, thoracic hypoplasia, rabbit eye, left inguinal hernia, and tricuspid valve regurgitation. Physical examination revealed an enlarged head due to skull dysplasia and hydrocephalus. The pediatrician confirmed that mask ventilation was possible even under spontaneous breathing, and that there was no history of bone fracture during mask holding. INTERVENTIONS AND OUTCOMES: The patient was scheduled for gastrostomy and ventriculo-peritoneal shunt implantation. An arterial pressure line was inserted at the neonatal intensive care unit. Propofol and remifentanil were selected for general anesthesia. Confirming that mask-assisted ventilation was possible under sleep, rocuronium was administered. Attentive mask ventilation was performed via the 2-person method to avoid fractures. We were able to intubate successfully using a Macintosh laryngoscope. A microcuff endotracheal tube was used. For ventilation, pressure control ventilation was selected and sedative dosage was adjusted using the patient state index as an indicator. The patient was sedated, intubated, and returned to the neonatal intensive care unit. She was extubated on the sixth postoperative day. No bone fractures were noted. CONCLUSION: OI type II is the most severe subtype with high mortality, and there are few reports on its anesthetic management. Easy fractures can be a problem in airway maintenance, blood pressure measurement, and repositioning. We performed the procedure attentively, avoiding jaw and cervical fractures during mask ventilation and endotracheal intubation. For respiratory management, we chose pressure control ventilation using a cuffed tracheal tube and circulatory control was attained via an arterial line inserted preoperatively. No complications occurred.


Assuntos
Anestesia Geral/métodos , Anestésicos , Osteogênese Imperfeita , Anestésicos/administração & dosagem , Feminino , Fraturas Ósseas , Humanos , Hidrocefalia , Osteogênese Imperfeita/complicações , Osteogênese Imperfeita/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...