Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.936
Filtrar
2.
BMC Cardiovasc Disord ; 24(1): 330, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38943106

RESUMO

BACKGROUND: The purpose of this study was to review echocardiography-based diagnosis of persistent fifth aortic arch (PFAA) in children. METHODS: From January 2015 to December 2022, we retrospectively analyzed the echocardiographic findings and the relevant clinical data during follow-up of patients with PFAA who were treated in the Third Affiliated Hospital of Zhengzhou University. The diagnosis was confirmed by computed tomography angiography or surgery. RESULTS: Seven PFAA cases included two Weinberg type A and five Weinberg type B. The anatomical details of PFAA were assessed using a combination of the long-axis view of the left ventricular outflow tract (from the left high parasternal window) and the long-axis view of the aortic arch (from the suprasternal window). In Weinberg type A, the distal fifth and fourth aortic arches were connected to the descending aorta, which was associated with aortic coarctation. In Weinberg type B, the upper arch of the fourth aorta was interrupted, and only the lower arch of the fifth aorta was connected to the descending aorta. Surgical repair of PFAA was indicated in five patients with blood flow disruption, among which four had good postoperative results and one refused surgery. Two patients with unobstructed PFAA blood flow required follow-up rather than surgery. CONCLUSIONS: It is feasible to diagnose PFAA by echocardiography. Combined application of the high parasternal left ventricular outflow tract view and the suprasternal aortic arch view can improve timely detection of different types of PFAA in children.


Assuntos
Aorta Torácica , Angiografia por Tomografia Computadorizada , Valor Preditivo dos Testes , Humanos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/anormalidades , Aorta Torácica/cirurgia , Estudos Retrospectivos , Masculino , Feminino , Lactente , Pré-Escolar , Aortografia , Criança , China , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/cirurgia , Resultado do Tratamento , Fatores Etários , Reprodutibilidade dos Testes , Ecocardiografia
3.
Vasa ; 53(4): 255-262, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38874211

RESUMO

Background: The clinical outcomes and survival of patients with penetrating aortic ulcers (PAU) were evaluated in a tertiary care hospital, comparing those who underwent aortic repair to those treated conservatively. Patients and methods: A retrospective single-centre analysis included all patients that underwent a computed tomography angiography (CT-A) scan with the diagnosis of a PAU between January 2009 and May 2019. "PAU" was identified in 1,493 of 112,506 CT-A scan reports in 576 patients. Clinical and angiomorphological data were collected. The primary outcome was overall survival (OS), with secondary outcomes focusing on identifying risk factors for poor OS. Survival probabilities were analysed by the Kaplan-Meier method using the log-rank test. A Cox hazard model using survival as dependent variable with stepwise backward eliminations based on the likelihood ratios was employed. Results: 315 PAUs were identified in 278 patients. The prevalence in the cohort was 0.8%. The mean age of the patients was 74.4 years, and they were predominantly male (n = 208, 74.8%). The mean ulcer depth was 11.8 mm (range 2-50 mm). Out of the patients, 232 were asymptomatic (83.5%). Among 178 PAUs (56.5%), high-risk factors, such as ulcer depth >10 mm, aortic diameter >40 mm, and ulcer length >20 mm, were observed. Aortic repair was associated with a better mean OS compared to conservatively managed patients (72.6 versus 32.2 months, p = 0.001). The Cox hazard model showed that ulcer depth >1 mm was associated with poor OS (HR 0.67, p = 0.048), while aortic repair was related to a better OS (HR 4.365, p<0.013). Conclusions: Aortic repair is associated with better OS, but this finding should be interpreted with caution because of differences in age and comorbidities between the groups. Further evaluation is warranted through prospective studies with randomized groups. Further assessment for angiomorphological parameters is recommended to identify patients at increased risk for poor OS.


Assuntos
Doenças da Aorta , Angiografia por Tomografia Computadorizada , Tratamento Conservador , Úlcera , Humanos , Masculino , Feminino , Úlcera/mortalidade , Úlcera/diagnóstico por imagem , Úlcera/terapia , Úlcera/cirurgia , Estudos Retrospectivos , Tratamento Conservador/efeitos adversos , Tratamento Conservador/mortalidade , Idoso , Fatores de Risco , Resultado do Tratamento , Fatores de Tempo , Doenças da Aorta/mortalidade , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/terapia , Doenças da Aorta/cirurgia , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Medição de Risco , Implante de Prótese Vascular/mortalidade , Implante de Prótese Vascular/efeitos adversos , Aortografia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Úlcera Aterosclerótica Penetrante
4.
Methodist Debakey Cardiovasc J ; 20(1): 45-48, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38855041

RESUMO

Left ventricular assist devices (LVAD) are frequently used in the management of end-stage heart failure, especially given the limited availability of donor hearts. The latest HeartMate 3 LVAD delivers non-physiological continuous flow (CF), although the impact on the aorta is not well established. We highlight a case of aortic aneurysm formation complicated by dissection formation that necessitated high-risk re-operative surgery in a patient post CF-LVAD.


Assuntos
Aneurisma Aórtico , Dissecção Aórtica , Implante de Prótese Vascular , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Dissecção Aórtica/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Dissecção Aórtica/fisiopatologia , Resultado do Tratamento , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Aneurisma Aórtico/cirurgia , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/etiologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/cirurgia , Masculino , Função Ventricular Esquerda , Reoperação , Pessoa de Meia-Idade , Aortografia , Angiografia por Tomografia Computadorizada , Desenho de Prótese
5.
Atherosclerosis ; 395: 118519, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38944894

RESUMO

BACKGROUND AND AIMS: The role of aortic mineralization in the pathogenesis of acute type B aortic dissection (TBAD) is unclear. Whether thoracic aortic calcification (TAC) and circulating alkaline phosphatase (ALP) activity are associated with acute TBAD risk remains elusive. METHODS: Observational and Mendelian randomization (MR) studies were conducted sequentially. Using propensity score matching (1:1) by age and sex, patients with acute TBAD (n = 125) were compared with control patients (n = 125). Qualitative (score) and quantitative (volume) analyses of the TAC burden on different thoracic aortic segments were conducted using non-enhanced computed tomography. Univariate and multivariate analyses were used to identify significant independent risk factors for TBAD and TAC burden, respectively. MR was finally used to determine the causal relationship between elevated ALP activity and TBAD risk. RESULTS: The qualitative and quantitative analyses revealed that TAC burden was significantly higher in the TBAD group, except for in the ascending aortic segment (both p < 0.05). Preoperative circulating ALP was significantly elevated in the TBAD group (p < 0.001). The elevated TAC burden score on the descending thoracic aortic segment (odds ratio [OR] 3.31, 95% confidence interval [CI] 1.31-8.37) and increased ALP activity (OR 1.03, 95% CI 1.01-1.06) was independently associated with TBAD risk. Interestingly, ALP was significantly positively associated with TAC burden, and MR analyses confirmed that ALP genetically predicted TBAD risk. CONCLUSIONS: Elevated ALP may trigger TBAD risk via the increased volume of TAC. Aortic mineralization may not protect the aorta itself.


Assuntos
Fosfatase Alcalina , Aneurisma da Aorta Torácica , Dissecção Aórtica , Análise da Randomização Mendeliana , Calcificação Vascular , Humanos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Masculino , Feminino , Pessoa de Meia-Idade , Fatores de Risco , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/genética , Calcificação Vascular/diagnóstico por imagem , Fosfatase Alcalina/sangue , Idoso , Doença Aguda , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/patologia , Medição de Risco , Estudos de Casos e Controles , Biomarcadores/sangue , Aortografia/métodos , Predisposição Genética para Doença , Angiografia por Tomografia Computadorizada
6.
BMC Cardiovasc Disord ; 24(1): 281, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38811879

RESUMO

BACKGROUND: Acute coronary syndrome due to coronary artery embolism in the setting of ascending aortic thrombus is an uncommon condition, even rarer when there is no aortic pathology such as aneurysm, severe atherosclerosis, aortic dissection, or thrombophilia (whether inherited or acquired). CASE PRESENTATION: We report a case of a 58-year-old male presented with acute chest pain, electrocardiogram showing non-ST-elevation acute coronary syndrome. The computed tomography angiography of coronary artery revealed a mural thrombus in the proximal part of ascending aorta, located above the left coronary artery ostium, without any aortic pathologies. With the exception of hypertension and cigarette smoking, no other risk factors were identified in this patient that may increase the risk of thrombosis. Given the life-threatening risk of interventional therapy and surgery, the patient determinedly opted for anticoagulant and dual antiplatelet therapy. Then he experienced the reoccurrence of chest pain after 6-day treatment, progressed to anterior and inferior ST-segment elevation myocardial infarction. Coronary artery embolism originating from the ascending aortic thrombus was suspected. Considering the hemodynamic instability of the patient, the medical treatment was continued and bridged to warfarin and aspirin after discharge. Follow-up computed tomography angiography at 6 months showed no obstruction in coronary artery and complete resolution of the thrombus. No thromboembolic events occurred henceforward. CONCLUSIONS: Acute coronary syndrome could be a manifestation of secondary coronary embolism due to ascending aortic thrombus. Currently, there is no standardized guideline for the treatment of aortic mural thrombus, individualized treatment is recommended. When surgical therapy is not applicable for the patient, anticoagulation and dual antiplatelet treatment are alternative treatments that may successfully lead to the resolution of the aortic thrombus.


Assuntos
Síndrome Coronariana Aguda , Doenças da Aorta , Recidiva , Humanos , Masculino , Pessoa de Meia-Idade , Síndrome Coronariana Aguda/etiologia , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/terapia , Síndrome Coronariana Aguda/diagnóstico por imagem , Resultado do Tratamento , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/etiologia , Doenças da Aorta/complicações , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/tratamento farmacológico , Anticoagulantes/uso terapêutico , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Inibidores da Agregação Plaquetária/uso terapêutico , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Infarto do Miocárdio sem Supradesnível do Segmento ST/etiologia , Aortografia
7.
Int J Cardiovasc Imaging ; 40(7): 1609-1611, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38702551

RESUMO

Thoracic aortic graft infections are infrequent yet grave complications of cardiovascular surgery. Risk factors include prolonged operative time, postoperative wound infections, and patient-specific risk factors like diabetes or malnutrition (Van Hemelrijck et al., Vessel Plus 6:47, 2022). In postoperative vascular scenarios, it is critical to utilize cross-sectional imaging to detect the presence of a complication, followed by describing the morphology, extent, and ancillary features. FDG-PET/CT can help differentiate between expected postoperative changes and worrisome infection by metabolic activity (FDG uptake). We present an extensive case of ascending aortic graft infection in the setting of ongoing sternal osteomyelitis. CT and PET/CT reveal chronic sternal osteomyelitic changes spreading into the retrosternal soft tissues, and a large intraluminal thrombus in the ascending aortic graft. Small mobile strands propagate toward the right brachiocephalic origin, posing a significant stroke risk. PET/CT confirmed postoperative infection by demonstrating increased FDG uptake.


Assuntos
Implante de Prótese Vascular , Prótese Vascular , Fluordesoxiglucose F18 , Osteomielite , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Valor Preditivo dos Testes , Infecções Relacionadas à Prótese , Esterno , Humanos , Osteomielite/diagnóstico por imagem , Osteomielite/etiologia , Osteomielite/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular/efeitos adversos , Doença Crônica , Resultado do Tratamento , Esterno/cirurgia , Esterno/diagnóstico por imagem , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/etiologia , Masculino , Fluordesoxiglucose F18/administração & dosagem , Fatores de Risco , Idoso , Antibacterianos/uso terapêutico , Compostos Radiofarmacêuticos , Aortografia/métodos , Pessoa de Meia-Idade
9.
Circ Cardiovasc Interv ; 17(7): e013729, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38666384

RESUMO

BACKGROUND: Transverse aortic arch obstruction is a challenging lesion for which stent implantation provides a potentially important alternate therapy. The objectives were to evaluate the technical, procedural, and medium-to-long-term clinical outcomes of percutaneous stent implantation of transverse aortic arch obstruction. METHODS: This is a retrospective, multicenter study of transverse aortic arch stent implantation. Univariable and multivariable analyses were performed. RESULTS: Index catheterization included 187 stent implants in 146 patients. The median age is 14.3 years (interquartile range, 9.3-19), weight is 53 kg (30-69), and follow-up is 53 months (12-120). The most common stent design was open cell (n=90, 48%). Stents overlapped 142 arch vessels (37 carotid arteries) in 118 (81%) cases. Technical and procedural success rates were 100% and 88%, respectively. Lower weight (P=0.018), body surface area (P=0.013), and minimum-to-descending aortic diameter ratio (P<0.001) were associated with higher baseline aortic gradient. The residual gradient was inversely associated with implant and final dilation diameters (P<0.001). The combined incidence of aortic injury and stent-related complications was 14%. There were no reports of abnormal brain scans or stroke. Blood pressure cuff gradient, echocardiographic arch velocity, and hypertension rates improved within 1-year follow-up with increased antihypertensive medication use. Reintervention was reported in 60 (41%) patients at a median of 84 (22-148) months to first reintervention. On multivariable logistic regression, residual aortic gradient >10 mm Hg was associated with increased odds of reintervention at all time points when controlling for each final dilation diameter, weight, and minimum-to-descending aortic diameter ratio. CONCLUSIONS: Transverse aortic arch stent implantation has high rates of technical, procedural, and medium-to-long-term clinical success. Aortic gradient >10 mm Hg is associated with increased odds of reintervention at 1-year and most recent follow-ups. Open cell stent design was frequently used for its advantages in conformability, perfusion of arch vessels, low fracture rate, and the ability to perform effective angioplasty of side cells.


Assuntos
Angioplastia com Balão , Aorta Torácica , Desenho de Prótese , Stents , Humanos , Estudos Retrospectivos , Masculino , Feminino , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aorta Torácica/fisiopatologia , Resultado do Tratamento , Fatores de Tempo , Fatores de Risco , Adolescente , Adulto Jovem , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos , Criança , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/terapia , Doenças da Aorta/fisiopatologia , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/fisiopatologia , Arteriopatias Oclusivas/terapia , Constrição Patológica , Estados Unidos , Aortografia
11.
Vasc Endovascular Surg ; 58(6): 595-601, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38607697

RESUMO

OBJECTIVE: The objective of this study was to investigate the flow effects in different degrees of thoracic aortic stent graft protrusion extension by creating bird beak effect simulations using accurate 3D geometry and a realistic, nonlinear, elastic biomechanical model using computer-aided software SolidWorks. METHODS: Segmentation in 3D of an aortic arch from a computed tomography (CT) scan of a real-life patient was performed using SolidWorks. A parametric analysis of three models was performed: (A) Aortic arch with no stent, (B) 3 mm bird-beak configuration, and (C) 6.5 mm bird-beak configuration. Flow velocity, pressure, vorticity, wall shear stress (WSS), and time average WSS were assessed. RESULTS: The flow velocity in Model A remained relatively constant and low in the area of the ostium of the brachiocephalic artery and doubled in the left subclavian artery. On the contrary, Models B and C showed a decrease in velocity of 52.3 % in the left subclavian artery. Furthermore, Model B showed a drop in velocity of 82.7% below the bird-beak area, whereas Model C showed a decline of 80.9% in this area. The pressure inside the supra-aortic branches was higher in Model B and C compared with Model A. In Model A, vorticity only appeared at the level of the descending aorta, with low to non-vorticity in the aortic arch. In contrast, Models B and C had an average vorticity of 241.4 Hz within the bird beak area. Regarding WSS, Model A, and Model B shared similar WSS in the peak systolic phase, in the aortic arch, and the bird beak area, whereas Model C had an increased WSS by 5 Pa on average at these zones. CONCLUSION: In the present simulations' lower velocities, higher pressures, vortices, and WSS were observed around the bird beak zone, the aortic arch, and the supra-aortic vessels.


Assuntos
Aorta Torácica , Aortografia , Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares , Hemodinâmica , Modelos Cardiovasculares , Stents , Estresse Mecânico , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Aorta Torácica/fisiologia , Humanos , Velocidade do Fluxo Sanguíneo , Procedimentos Endovasculares/instrumentação , Implante de Prótese Vascular/instrumentação , Simulação por Computador , Fluxo Sanguíneo Regional , Modelagem Computacional Específica para o Paciente , Desenho de Prótese , Pressão Arterial , Dinâmica não Linear , Fenômenos Biomecânicos , Interpretação de Imagem Radiográfica Assistida por Computador
12.
J Cardiovasc Surg (Torino) ; 65(2): 110-118, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38635286

RESUMO

BACKGROUND: The aim of this study was to evaluate the anatomical feasibility of current available fenestrated endografts (FEVAR) and on-label chimney technique (EnChEVAR) in patients with complex abdominal aortic aneurysms (C-AAA). METHODS: Feasibility of EnChEVAR (Endurant II/IIS CE-marked [Medtronic]) and 4 types of FEVAR (Zenith Fenestrated CE-marked, Zenith Fenestrated Low-Profile [LP] custom-made device [CMD] [Cook Medical], Fenestrated Anaconda LoPro90 CMD, Fenestrated Treo CMD [Terumo Aortic]) was assessed according to the manufacturer's instructions for use. Computed tomography angiograms of patients with C-AAA previously included in the Protagoras 2.0 study were retrospectively reviewed. The aortic coverage was ideally planned to involve a maximum of two chimney grafts or fenestrations. RESULTS: Iliac access and aortic neck of 73 C-AAAs were analyzed. The overall feasibility was significantly different between EnChEVAR (33%) and FEVAR (Zenith Fenestrated 15%, Zenith Fenestrated LP 15%, Fenestrated Anaconda LoPro90 45%, Fenestrated Treo 48%). The iliac access feasibility was significantly lower for Zenith Fenestrated with standard profile compared to all other grafts. The aortic neck feasibility was significantly higher for EnChEVAR and both Terumo Aortic fenestrated stent grafts, compared to both Cook Medical grafts. The treatment using any of the three current available fenestrated grafts with lower profile (Zenith Fenestrated LP, Fenestrated Anaconda LoPro90, Fenestrated Treo) would have been feasible in 71% of the cases. CONCLUSIONS: Most of the patients treated by ChEVAR would have not been treated by first generation fenestrated stent graft. The current available fenestrated endografts, with lower profile and suitable also for angulated necks, increase the anatomical feasibility.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Stents , Feminino , Humanos , Masculino , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Meios de Contraste , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 103(6): 1074-1077, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38577923

RESUMO

Transcatheter aortic valve implantation (TAVI) has traditionally been indicated for the treatment of aortic stenosis. However, in this case report, we describe a successful TAVI procedure in a 46-year-old male patient who had previously undergone David aortic valve-sparing aortic root replacement for type 1 aortic dissection. The patient presented with aortic valve insufficiency 4 years after the initial surgery and was subsequently treated with a 34 mm Medtronic CoreValve Evolut R prosthesis via TAVI. This case highlights the feasibility of TAVI as a viable treatment option for postoperative aortic valve insufficiency in patients with prior ascending aortic or aortic arch surgery.


Assuntos
Dissecção Aórtica , Insuficiência da Valva Aórtica , Valva Aórtica , Implante de Prótese Vascular , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Dissecção Aórtica/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/fisiopatologia , Pessoa de Meia-Idade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Desenho de Prótese , Prótese Vascular , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Aneurisma Aórtico/diagnóstico por imagem , Aortografia
15.
Vasc Endovascular Surg ; 58(6): 663-668, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38527219

RESUMO

INTRODUCTION: Patients with complex aortic anatomy require meticulous surgical planning to optimize intraoperative and postoperative outcomes. The GORE Excluder Conformable Abdominal Aortic Aneurysm Endoprosthesis (CEXC Device, WL Gore and Associates, Flagstaff, AZ) allows for endovascular treatment of highly angulated and short proximal neck abdominal aortic aneurysms (AAA). Owing to its recent approval, short-term clinical outcomes of this device remain scarce. REPORT: In this report, we present a case series of 3 patients who underwent endovascular aortic repair using the GORE Excluder Conformable device with highly angulated (>70°) aortic neck anatomy. Endografts were deployed in a radiology suite using standard 2D angiography in conjunction with a CYDAR Medical (Wilmington, Delaware) reconstructed 3D overlay. The patients' ages were 85, 67, and 85 years. The mean abdominal aortic aneurysm diameter in these cases was 6.9 cm. The mean proximal neck length was 2.1 cm, proximal mean neck angulation was 83°. The mean operative time, total fluoroscopy time, and contrast used were 208 minutes, 28.3°minutes, and 94.5 milliliters, respectively. No adjunctive procedures, such as proximal cuff or endo-anchors, were performed at the time of index procedure. DISCUSSION: Type Ia endoleak was observed in 1 patient post-operatively but after treatment with an aortic cuff there was no evidence of enlarging aneurysm sac. The GORE Excluder Conformable Endoprosthesis expands access to endovascular management of AAAs. Our early experience with this device demonstrated excellent patient and clinical outcomes in a highly angulated neck anatomy.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Desenho de Prótese , Stents , Idoso , Idoso de 80 Anos ou mais , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Fatores de Tempo , Resultado do Tratamento
16.
Vasc Endovascular Surg ; 58(6): 655-658, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38491914

RESUMO

BACKGROUND: Vascular graft infection is a very complex disease. Although complete excision of the infected grafts with extra-anatomic bypass or in situ reconstruction is a general treatment strategy, some concerns including reinfection in the new graft remain. CASE REPORT: An 88 year-old man presented to the hospital with abdominal swelling and bleeding. The patient had undergone revascularization for aorto-iliac occlusive disease twice in the past. The first procedure had been performed 15 years previously, with right ilio-femoral bypass grafting for right iliac artery occlusion and stent implantation for left iliac artery stenosis. The second procedure had been performed 10 years previously, with aorta-to-left femoral and left-to-right femoro-femoral bypass grafting because the terminal aorta, the first ilio-femoral bypass graft, and the stent of the left iliac artery had been occluded. The patient was diagnosed with vascular graft infection, and endovascular therapy was selected as the revascularization method prior to graft excision. It was successfully performed using various devices and techniques, followed by graft excision without critical limb ischemia. CONCLUSION: This case demonstrates that endovascular therapy prior to graft excision can be an alternative revascularization method for vascular graft infection after bypass surgery for aorto-iliac occlusive disease.


Assuntos
Doenças da Aorta , Arteriopatias Oclusivas , Implante de Prótese Vascular , Prótese Vascular , Remoção de Dispositivo , Artéria Ilíaca , Infecções Relacionadas à Prótese , Humanos , Masculino , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/diagnóstico por imagem , Resultado do Tratamento , Idoso de 80 Anos ou mais , Artéria Ilíaca/cirurgia , Artéria Ilíaca/diagnóstico por imagem , Doenças da Aorta/cirurgia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/etiologia , Arteriopatias Oclusivas/cirurgia , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/etiologia , Stents , Reoperação , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Angiografia por Tomografia Computadorizada , Aortografia
17.
Vasc Endovascular Surg ; 58(6): 683-684, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38509023
18.
J Vasc Surg ; 80(1): 107-113, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38485071

RESUMO

OBJECTIVE: Though initially protected from vessel dilation by estrogen, women may experience rapid abdominal aortic aneurysm (AAA) growth post-menopause. The rate of growth has been poorly defined in prior literature. Here, we describe aneurysm growth in a cohort of women found through an AAA screening program. METHODS: Women with AAAs were retrospectively identified. Aortic imaging was reviewed, and measurements of maximum transverse and anterior-posterior diameters were completed. Growth was stratified by the type of aortic pathology (fusiform aneurysm, aortic ectasia, dissection with aneurysmal degeneration, saccular aneurysm) as well as size category (<3 cm, 3.0-3.9 cm, 4.0-4.9 cm, ≥5.0 cm) at diagnosis. RESULTS: A cohort of 488 women was identified; 286 had multiple scans for review. The mean age of the entire cohort was 75 ± 9.9 years. Stratified by type of pathology, the mean age was 76 ± 8.9 years in patients with a fusiform AAA, 74 ± 9.8 years in ectasia, 65 ± 13.7 years in dissection, and 76 ± 5.6 years in saccular aneurysms. The maximum growth was highest in women with fusiform AAAs, followed by dissection, ectasia, and saccular pathology (9.7 mm, 7.0 mm, 3.0 mm, and 2.2 mm, respectively; P < .001). Comparing mean growth by year, the highest mean growth was in fusiform AAAs (3.6 mm vs 1.75 mm in dissection; P < .001). The Shapiro-Wilk test demonstrated that mean growth per year was non-normally distributed with a right skew. Stratified by aortic diameter at the time of diagnosis, mean growth/year increased with increasing size at diagnosis in fusiform AAAs and dissection (0.91 mm for <3 cm, 2.34 mm for 3.0-3.9 cm, 2.49 mm for 4.0-4.9 mm, and 6.16 mm for ≥5.0 cm in patients with fusiform AAAs vs 0.57 mm, 0.94 mm, 1.87 mm, and 2.66 mm, respectively, for patients with dissection). Smoking history was associated with a higher mean growth/year (2.6 mm vs 3.3 mm; P < .001). Conversely, patients with a family history of AAA had a lower mean growth/year (3.2 mm vs 1.5 mm; P < .001). CONCLUSIONS: The rate of aneurysm growth in women varies based on pathology and aneurysm size, and women experience rapid aneurysm growth at sizes greater than 4.5 cm. Current screening guidelines are inadequate, and our results demonstrate that the rate of growth of fusiform aneurysms in women is faster than in men at a smaller size and may warrant more frequent surveillance than current Society for Vascular Surgery recommendations to prevent risk of increased morbidity.


Assuntos
Aneurisma da Aorta Abdominal , Progressão da Doença , Humanos , Feminino , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/epidemiologia , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Fatores de Risco , Fatores de Tempo , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/patologia , Angiografia por Tomografia Computadorizada , Aortografia , Fatores Sexuais , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/epidemiologia , Dilatação Patológica , Pós-Menopausa
19.
Ann Vasc Surg ; 104: 237-247, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38492732

RESUMO

BACKGROUND: Fenestrated (FEVAR) and chimney (ChEVAR) endovascular aortic repair have been applied in anatomically suitable complex aortic aneurysms. However, local hemodynamic changes may occur after repair. This study aimed to compare FEVAR's and ChEVAR's hemodynamic properties, focusing on visceral arteries. METHODS: Preoperative and postoperative computed tomography angiographies have been used to reconstruct patient-based models. Data of 3 patients, for each modality, were analyzed. Following geometric reconstruction, computational fluid dynamics simulations were used to extract near-wall and intravascular hemodynamic indicators, such as pressure drops, velocity, wall shear stress, time averaged wall shear stress, oscillatory shear index, relative residence time, and local normalized helicity. RESULTS: An overall improvement in hemodynamics was detected after repair, with either technique. Preoperatively, a disturbed prothrombotic wall shear stress profile was recorded in several zones of the sac. The local normalized helicity results showed a better organization of the helical structures at postoperative setting, decreasing thrombus formation, with both modalities. Similarly, time averaged wall shear stress increased and oscillatory shear index decreased postoperatively, signaling nondisturbed blood flow. The relative residence time was locally reduced. The flow in visceral arteries tended to be more streamlined in ChEVAR, compared to evident recirculation regions at renal and superior mesenteric artery fenestrations (P = 0.06). CONCLUSIONS: ChEVAR and FEVAR seem to improve hemodynamics toward normal values with a reduction of recirculation zones in the main graft and aortic branches. Visceral artery flow comparison revealed that ChEVAR tended to present lower recirculation regions at parallel grafts' entries while FEVAR showed less intense flow regurgitation in visceral stents.


Assuntos
Implante de Prótese Vascular , Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares , Hemodinâmica , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Desenho de Prótese , Estresse Mecânico , Humanos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Velocidade do Fluxo Sanguíneo , Fatores de Tempo , Aortografia , Fluxo Sanguíneo Regional , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Idoso , Masculino , Stents , Hidrodinâmica , Correção Endovascular de Aneurisma
20.
Asian Cardiovasc Thorac Ann ; 32(4): 215-218, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38483813

RESUMO

Various surgical techniques have been developed for coarctation of the aorta. However, coarctation repair in neonates with arch hypoplasia remains challenging. We herein report a case in which a premature neonate under 1500 g with coarctation of the aorta and arch hypoplasia underwent an extra-anatomical bypass at 18 days old. A second extra-anatomical bypass was performed at 3 years of age, and a third extra-anatomic bypass for recurrent coarctation was performed in adulthood. By increasing the size of the graft as the patient grows, extra-anatomic bypass can be a useful surgical option for premature neonates with coarctation and arch hypoplasia.


Assuntos
Aorta Torácica , Coartação Aórtica , Implante de Prótese Vascular , Humanos , Coartação Aórtica/cirurgia , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/complicações , Recém-Nascido , Aorta Torácica/cirurgia , Aorta Torácica/anormalidades , Aorta Torácica/diagnóstico por imagem , Resultado do Tratamento , Implante de Prótese Vascular/instrumentação , Masculino , Recém-Nascido Prematuro , Aortografia , Recidiva , Prótese Vascular , Angiografia por Tomografia Computadorizada , Fatores Etários , Idade Gestacional , Pré-Escolar , Adulto , Feminino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...