Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.285
Filtrar
1.
J Am Coll Radiol ; 21(6S): S237-S248, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38823947

RESUMO

This document summarizes the relevant literature for the selection of preprocedural imaging in three clinical scenarios in patients needing endovascular treatment or cardioversion of atrial fibrillation. These clinical scenarios include preprocedural imaging prior to radiofrequency ablation; prior to left atrial appendage occlusion; and prior to cardioversion. The appropriateness of imaging modalities as they apply to each clinical scenario is rated as usually appropriate, may be appropriate, and usually not appropriate to assist the selection of the most appropriate imaging modality in the corresponding clinical scenarios. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Assuntos
Fibrilação Atrial , Medicina Baseada em Evidências , Sociedades Médicas , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Humanos , Estados Unidos , Cuidados Pré-Operatórios/métodos , Cardioversão Elétrica/métodos , Átrios do Coração/diagnóstico por imagem , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia
2.
J Cardiothorac Surg ; 19(1): 327, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38849837

RESUMO

BACKGROUND: Left atrial appendage aneurysm is a rare cardiac mass, with only a few cases reported. There are usually no specific symptoms, and a few patients visit the doctor with symptoms. CASE PRESENTATION: A 20-year-old male presented to our hospital with a "pericardial cyst found by medical evaluation in another hospital for 2 years." Cardiac ultrasound performed at clinics of our hospital suggested a cystic dark area in the left ventricular lateral wall and the anterior lateral wall, consistent with a pericardial cyst and mild mitral regurgitation. After further relevant examinations and ruling out contraindications, an excision of the left atrial appendage aneurysm was performed under general anesthesia and cardiopulmonary bypass with beating-heart. The postoperative pathological results identified that: (left atrial appendage) fibrocystic wall-like tissue with a focal lining of the flat epithelium, consistent with a benign cyst. CONCLUSION: Left atrial appendage aneurysms are rare and insidious. They are usually found by chance during medical evaluations. If the location is not good or the volume is too large, then compression symptoms or arrhythmia, thrombosis and other concomitant symptoms will occur. Surgical resection is presently the only effective radical cure for a left atrial appendage aneurysm.


Assuntos
Apêndice Atrial , Aneurisma Cardíaco , Humanos , Masculino , Apêndice Atrial/cirurgia , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/patologia , Aneurisma Cardíaco/cirurgia , Aneurisma Cardíaco/diagnóstico por imagem , Aneurisma Cardíaco/diagnóstico , Adulto Jovem , Ecocardiografia , Procedimentos Cirúrgicos Cardíacos/métodos
3.
BMC Cardiovasc Disord ; 24(1): 293, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844866

RESUMO

Patients with previous interatrial shunt device (IASD) implantation may face greater challenges during future left atrial interventional procedures. Herein, we report the first case of left atrial appendage closure (LAAC) in a patient with previous IASD implantation. The patient successfully underwent LAAC using the LAmbre device without complications.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Humanos , Apêndice Atrial/fisiopatologia , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/instrumentação , Masculino , Feminino , Ecocardiografia Transesofagiana , Idoso , Função do Átrio Esquerdo , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/terapia , Forame Oval Patente/complicações , Forame Oval Patente/fisiopatologia , Forame Oval Patente/cirurgia , Oclusão do Apêndice Atrial Esquerdo
4.
EuroIntervention ; 20(11): e718-e727, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38840576

RESUMO

BACKGROUND: Left atrial appendage occlusion (LAAO) is performed increasingly, but long-term follow-up imaging data are lacking. AIMS: The aim of this study was to evaluate the safety and durability of the Amplatzer Amulet device >4 years after LAAO. METHODS: This was a prospective observational cohort study including 52 patients implanted with the Amplatzer Amulet device at Aarhus University Hospital, Denmark. A >4-year follow-up cardiac computed tomography (CT) scan after LAAO was performed and compared with the results from the 2-month and 12-month scans. The primary outcome was left atrial appendage (LAA) sealing based on distal LAA contrast patency and peridevice leakage (PDL), stratified into complete occlusion (grade 0 [G0]) and grade 1-3 leakage (G1-3), respectively. Secondary outcomes were low- and high-grade hypoattenuated thickening (HAT), device-related thrombosis (DRT) and device durability. RESULTS: The median (interquartile range [IQR]) follow-up time from LAAO to the latest CT scan was 5.8 years (4.5; 6.3). At 2-month (n=52), 12-month (n=27) and >4-year CT follow-ups (n=52), rates of both complete occlusion (33%, 37%, 35%) and G2 leaks (52%, 52%, 48%) remained stable. Rates of G1 leaks varied (14%, 4%, 6%) and G3 leaks rose (2%, 7%, 12%) from earliest to latest follow-up. The median left atrial (LA) volume increased from 127 mL (96; 176) to 144 mL (108; 182) and 147 mL (107; 193). No DRT was found. The structural device integrity was preserved. CONCLUSIONS: This study indicates a stable LAA sealing status throughout the follow-up period, emphasising the importance of the procedural result in avoiding PDL. Few patients displayed PDL progression, which might partly be related to LA remodelling with increasing volume. The long-term device durability appears excellent. Larger studies are warranted to confirm these findings.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Tomografia Computadorizada por Raios X , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Apêndice Atrial/fisiopatologia , Masculino , Feminino , Idoso , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Estudos Prospectivos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Seguimentos , Pessoa de Meia-Idade , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação
6.
Sci Rep ; 14(1): 11937, 2024 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-38789491

RESUMO

Transesophageal echocardiography (TEE) has been the preferred imaging modality to help guide left atrial appendage closure. Newer technologies such as the Nuvision 4D Intracardiac echocardiography (ICE) catheter allow for real-time 3D imaging of cardiac anatomy. There are no direct comparison studies for procedural imaging between TEE and 4D ICE. To evaluate the performance and safety of left atrial appendage (LAA) closure procedures with the Watchman FLX and Amulet, guided by the Nuvision 4D ICE Catheter. This retrospective observational analysis was conducted on institutional LAAO National Cardiovascular Data Registry from January 2022 to March 2023. Patients had undergone LAA closure procedures with the Watchman FLX or Amulet device guided by TEE or a 4D ICE Catheter. The primary outcome evaluated was successful LAAO device placement. A total of 121 patients underwent LAAO device placement with 46 (38.0%) patients guided by 4D ICE during LAAO implantation. The 4D ICE group had a shorter procedural time compared with TEE guidance. Post procedural 45-day TEE post implant was also comparable for both groups with no patients in either group having incomplete closure of the left atrial appendage and peri-device leak > 5 mm. No device related complications (device related access, stroke, or pericardial effusion) occurred in either group at follow-up. There was no significant difference in device implant success or post procedural outcomes at 45 days in either the TEE or 4D ICE group. However, there was a noticeable improvement in procedural time with the 4D ICE catheter.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ecocardiografia Transesofagiana , Humanos , Apêndice Atrial/cirurgia , Apêndice Atrial/diagnóstico por imagem , Masculino , Feminino , Idoso , Estudos Retrospectivos , Ecocardiografia Transesofagiana/métodos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Idoso de 80 Anos ou mais , Ecocardiografia Tridimensional/métodos , Pessoa de Meia-Idade , Ecocardiografia/métodos , Resultado do Tratamento , Cateteres Cardíacos , Oclusão do Apêndice Atrial Esquerdo
7.
Medicine (Baltimore) ; 103(21): e38206, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38788025

RESUMO

OBJECTIVE: To evaluate left atrial volume and function in patients with paroxysmal atrial fibrillation (AF) combined with left atrial appendage thrombosis and patients with paroxysmal AF without left atrial appendage thrombosis by 3-dimensional speckle tracking imaging (3D-STI), and to explore the application value of this set of parameters in the evaluation of left atrial function in patients with paroxysmal AF. MATERIALS AND METHODS: A total of 40 patients with paroxysmal AF admitted from December 2018 to December 2020 were selected as the observation group. All patients with paroxysmal AF in the observation group underwent transesophageal echocardiography. According to the presence of left atrial appendage thrombosis, the patients were divided into the AF without thrombosis group (24 cases) and the AF with thrombosis group (16 cases). Thirty normal people were selected as control group who were chosen as having no heart-related disease. The left atrial volume parameters (Left atrial maximum volume LAVmax, Left atrial minimum volume LAVmin, Left atrial volume before atrial contraction LAVpre-A, Left atrial stroke volume LAEV), left atrial ejection fraction (LAEF) and left atrial strain parameters (Left atrial reservoir longitudinal strain LASr, Left atrial conduit longitudinal strain LAScd, Left atrial contraction longitudinal strain LASct, Left atrial reservoir circumferential strain LASr-c, Left atrial conduit circumferential strain LAScd-c, Left atrial contraction circumferential strain LASct-c) of the 3 groups were measured by 3D-STI. RESULTS: With the progression of paroxysmal AF, the left atrial volume increased, and the reservoir, conduit and contractile function were damaged. The left atrial volume continued to increase, and the reservoir, conduit and contractile function further decreased significantly in patients with AF combined with left atrial appendage thrombosis. LAEF was positively correlated with LASr and LASr_c. CONCLUSION: Real-time 3-dimensional spot tracking imaging (3D-STI) can evaluate the changes in left atrial volume and function in patients with paroxysmal AF, and has a certain reference value for clinical judgment of disease progression and prognosis.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Função do Átrio Esquerdo , Humanos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Função do Átrio Esquerdo/fisiologia , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Ecocardiografia Tridimensional/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Ecocardiografia Transesofagiana/métodos , Idoso , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/fisiopatologia
8.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38691672

RESUMO

AIMS: Blood stasis is crucial in developing left atrial (LA) thrombi. LA appendage peak flow velocity (LAAFV) is a quantitative parameter for estimating thromboembolic risk. However, its impact on LA thrombus resolution and clinical outcomes remains unclear. METHODS AND RESULTS: The LAT study was a multicentre observational study investigating patients with atrial fibrillation (AF) and silent LA thrombi detected by transoesophageal echocardiography (TEE). Among 17 436 TEE procedures for patients with AF, 297 patients (1.7%) had silent LA thrombi. Excluding patients without follow-up examinations, we enrolled 169 whose baseline LAAFV was available. Oral anticoagulation use increased from 85.7% at baseline to 97.0% at the final follow-up (P < 0.001). During 1 year, LA thrombus resolution was confirmed in 130 (76.9%) patients within 76 (34-138) days. Conversely, 26 had residual LA thrombi, 8 had thromboembolisms, and 5 required surgical removal. These patients with failed thrombus resolution had lower baseline LAAFV than those with successful resolution (18.0 [15.8-22.0] vs. 22.2 [17.0-35.0], P = 0.003). Despite limited predictive power (area under the curve, 0.659; P = 0.001), LAAFV ≤ 20.0 cm/s (best cut-off) significantly predicted failed LA thrombus resolution, even after adjusting for potential confounders (odds ratio, 2.72; 95% confidence interval, 1.22-6.09; P = 0.015). The incidence of adverse outcomes including ischaemic stroke/systemic embolism, major bleeding, or all-cause death was significantly higher in patients with reduced LAAFV than in those with preserved LAAFV (28.4% vs. 11.6%, log-rank P = 0.005). CONCLUSION: Failed LA thrombus resolution was not rare in patients with AF and silent LA thrombi. Reduced LAAFV was associated with failed LA thrombus resolution and adverse clinical outcomes.


Assuntos
Anticoagulantes , Apêndice Atrial , Fibrilação Atrial , Ecocardiografia Transesofagiana , Trombose , Humanos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/complicações , Masculino , Feminino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Idoso , Trombose/fisiopatologia , Trombose/diagnóstico por imagem , Trombose/complicações , Pessoa de Meia-Idade , Velocidade do Fluxo Sanguíneo , Anticoagulantes/uso terapêutico , Fatores de Risco , Resultado do Tratamento , Doenças Assintomáticas , Fatores de Tempo , Cardiopatias/fisiopatologia , Cardiopatias/complicações , Cardiopatias/diagnóstico por imagem , Tromboembolia/etiologia , Tromboembolia/fisiopatologia , Idoso de 80 Anos ou mais , Função do Átrio Esquerdo
9.
JACC Cardiovasc Interv ; 17(11): 1295-1307, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38795087

RESUMO

BACKGROUND: Pericardial effusion (PE) is the most common serious left atrial appendage closure (LAAC) complication, but its mechanisms, time course, and prognostic impact are poorly understood. OBJECTIVES: This study sought to assess the frequency, timing, predictors and clinical impact of PE after LAAC. METHODS: Data on consecutive patients undergoing percutaneous LAAC between 2009 and 2022 were prospectively collected including the 1-year follow-up. Both single (Watchman 2.5/FLX, Boston Scientific) and double (Amplatzer Cardiac Plug or Amulet, St. Jude Medical/Abbott) LAAC devices were used. An imaging core laboratory adjudicated the PEs and categorized them as early (≤7 days) and late (8-365 days). Logistic regression analysis was used to identify predictors of early and overall PE. RESULTS: Of 1,023 attempted LAAC procedures, PE was observed in 44 (4.3%) patients; PE was categorized as early in 34 (3.3%) and late in 10 (0.9%) patients. The majority of PEs occurred within 6 hours after LAAC (n = 25, 56.8%) and were clinically relevant (n = 28, 63.6%). Independent predictors of early PE were double-closure left atrial appendage devices (adjusted OR: 8.20; 95% CI: 1.09-61.69), female sex (adjusted OR: 3.41; 95% CI: 1.50-7.73), the use of oral anticoagulation (OAC) at baseline (adjusted OR: 2.60; 95% CI: 1.11-6.09), and advanced age (adjusted OR: 1.07; 95% CI: 1.01-1.23), whereas female sex and OAC at baseline remained independent predictors of overall PE. CONCLUSIONS: In this large LAAC registry, PE was observed in <1 in 20 patients and usually occurred within 6 hours after procedure. The majority of early PEs were clinically relevant and occurred in the Amplatzer Cardiac Plug/Amulet procedures. Independent predictors included the use of double-closure devices, female sex, OAC at baseline, and advanced age. (LAAC-registry: Clinical Outcome After Echocardiography-guided LAA-closure; NCT04628078).


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Derrame Pericárdico , Humanos , Feminino , Masculino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fatores de Tempo , Idoso , Fatores de Risco , Derrame Pericárdico/etiologia , Derrame Pericárdico/diagnóstico por imagem , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/complicações , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Resultado do Tratamento , Idoso de 80 Anos ou mais , Medição de Risco , Dispositivo para Oclusão Septal , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores Sexuais , Anticoagulantes/administração & dosagem , Anticoagulantes/uso terapêutico , Anticoagulantes/efeitos adversos , Oclusão do Apêndice Atrial Esquerdo
11.
JACC Cardiovasc Interv ; 17(11): 1311-1321, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38795093

RESUMO

BACKGROUND: Left atrial appendage occlusion (LAAO) provides mechanical cardioembolic protection for atrial fibrillation (AF) patients who cannot use oral anticoagulation therapy (OAT). Patients with a thrombotic event despite OAT are at high risk for recurrence and may also benefit from LAAO. OBJECTIVES: This study sought to investigate the efficacy of LAAO in AF patients with a thrombotic event on OAT compared to: 1) LAAO in AF patients with a contraindication for OAT; and 2) historical data. METHODS: The international LAAO after stroke despite oral anticoagulation (STR-OAC LAAO) collaboration included patients who underwent LAAO because of thrombotic events on OAT. This cohort underwent propensity score matching and was compared to the EWOLUTION (Evaluating Real-Life Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology) registry, which represents patients who underwent LAAO because of OAT contraindications. The primary outcome was ischemic stroke. Event rates were compared between cohorts and with historical data without OAT, yielding relative risk reductions based on risk scores. RESULTS: Analysis of 438 matched pairs revealed no significant difference in the ischemic stroke rate between the STR-OAC LAAO and EWOLUTION cohorts (2.5% vs 1.9%; HR: 1.37; 95% CI: 0.72-2.61). STR-OAC LAAO patients exhibited a higher thromboembolic risk (HR: 1.71; 95% CI: 1.04-2.83) but lower bleeding risk (HR: 0.39; 95% CI: 0.18-0.88) compared to EWOLUTION patients. The mortality rate was slightly higher in EWOLUTION (4.3% vs 6.9%; log-rank P = 0.028). Relative risk reductions for ischemic stroke were 70% and 78% in STR-OAC LAAO and EWOLUTION, respectively, compared to historical data without OAT. CONCLUSIONS: LAAO in patients with a thrombotic event on OAT demonstrated comparable stroke rates to the OAT contraindicated population in EWOLUTION. The thromboembolic event rate was higher and the bleeding rate lower, reflecting the intrinsically different risk profile of both populations. Until randomized trials are available, LAAO may be considered in patients with an ischemic event on OAT.


Assuntos
Anticoagulantes , Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Contraindicações de Medicamentos , AVC Isquêmico , Sistema de Registros , Humanos , Apêndice Atrial/fisiopatologia , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/complicações , Fibrilação Atrial/mortalidade , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/terapia , Feminino , Masculino , Anticoagulantes/efeitos adversos , Anticoagulantes/administração & dosagem , Idoso , Fatores de Risco , Medição de Risco , Idoso de 80 Anos ou mais , Fatores de Tempo , Administração Oral , AVC Isquêmico/prevenção & controle , AVC Isquêmico/mortalidade , AVC Isquêmico/diagnóstico , AVC Isquêmico/etiologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Falha de Tratamento , Hemorragia/induzido quimicamente , Recidiva , Pessoa de Meia-Idade , Estudos Retrospectivos , Europa (Continente)
12.
Ann Noninvasive Electrocardiol ; 29(3): e13119, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38682420

RESUMO

BACKGROUND: To avoid causing a thromboembolic event in patients undergoing catheter ablation for atrial fibrillation (AF), patients are treated with oral anticoagulants (OAC) prior to the procedure. Despite being on anticoagulants, some patients develop a left atrial appendage thrombus (LAAT). To exclude the presence of LAAT, transesophageal ultrasound (TEE) is performed in all patients prior to the procedure. We hypothesized continuous treatment with anticoagulants would result in a low prevalence of LAAT, in patients with low CHA2DS2-VASc score. METHOD: Medical records of consecutive patients planned to undergo AF ablation at Lund University Hospital during the years 2018-2020 were reviewed retrospectively. Examination protocols from transesophageal and transthoracic echocardiography were examined for LAAT and spontaneous echo contrast (SEC). Patients with LAAT and SEC were compared to patients without using Mann-Whitney U-test and Pearson Chi-squared analysis to test for correlation. RESULTS: Of 553 patients, three patients (0.54%) had LAAT, and 18 (3.25%) had spontaneous contrast (SEC). Patients with LAAT or SEC had a higher CHA2DS2-VASc score, more often presented in AF at TEE and less often had a normal sized left atrium. CONCLUSION: There is a low prevalence of LAAT and SEC in patients with AF scheduled for pulmonary vein isolation. Patients with SEC or LAAT tend to have paroxysmal AF less often and more often presented in AF at admission. No patients with CHA2DS2-VASc 0, paroxysmal AF, normal sized left atrium and sinus rhythm at TEE were found to have LAAT or SEC.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Ecocardiografia Transesofagiana , Veias Pulmonares , Trombose , Humanos , Ecocardiografia Transesofagiana/métodos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Masculino , Feminino , Veias Pulmonares/cirurgia , Veias Pulmonares/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Ablação por Cateter/métodos , Estudos Retrospectivos , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Prevalência , Pessoa de Meia-Idade , Idoso , Anticoagulantes/uso terapêutico , Cardiopatias/diagnóstico por imagem , Cardiopatias/epidemiologia
13.
Catheter Cardiovasc Interv ; 103(6): 995-1003, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38662126

RESUMO

BACKGROUND: Limited data exists regarding incidence, progression, and predictors of left atrial appendage (LAA) sealing after transcatheter LAA closure. We aimed to evaluate the incidence, progression, and predictive factors associated with LAA sealing after LAA closure. METHODS: This study includes patients who underwent successful LAA closure with Watchman FLX device and had both pre- and postprocedural computed tomography (CT). Postprocedural CT was performed 45 days after LAA closure and used to evaluate residual LAA patency. Patient who had residual LAA patency at 45 days underwent 1-year follow-up CT. RESULTS: A total of 105 patients (mean age: 75.2 ± 9.6 years; 53.3% female) who underwent successful LAA closure with Watchman FLX device and had pre- and postprocedural CT at 45 days were included. Residual patency was observed in 35 (33.3%) patients: 21 (20.0%) patients showed complete contrast opacification in LAA (complete LAA patency) while 14 (13.3%) patients showed contrast opacification only in the distal LAA (distal LAA patency). Among patients with residual LAA patency at 45 days, the rate of LAA sealing at 1 year was significantly higher in the distal LAA patency group than in the complete LAA patency group (75.0% vs. 16.7%; p = 0.019). Increased depth oversizing was associated with both distal LAA patency and complete LAA patency. CONCLUSION: Postprocedural CT at 45 days detected patent LAA in one-third of patients after LAA closure. LAA sealing was more frequently observed at 1 year among the distal LAA patency group than the complete LAA patency group.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Valor Preditivo dos Testes , Desenho de Prótese , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Feminino , Masculino , Idoso , Idoso de 80 Anos ou mais , Fatores de Risco , Resultado do Tratamento , Fatores de Tempo , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Estudos Retrospectivos , Incidência , Tomografia Computadorizada por Raios X , Tomografia Computadorizada Multidetectores
14.
Circ Cardiovasc Interv ; 17(5): e013579, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38629273

RESUMO

BACKGROUND: The prognostic impact of left atrial appendage (LAA) patency, including those with and without visible peri-device leak (PDL), post-LAA closure in patients with atrial fibrillation, remains elusive. METHODS: Patients with atrial fibrillation implanted with the WATCHMAN 2.5 device were prospectively enrolled. The device surveillance by cardiac computed tomography angiography was performed at 3 months post-procedure. Adverse events, including stroke/transient ischemic attack (TIA), major bleeding, cardiovascular death, all-cause death, and the combined major adverse events (MAEs), were compared between patients with complete closure and LAA patency. RESULTS: Among 519 patients with cardiac computed tomography angiography surveillance at 3 months post-LAA closure, 271 (52.2%) showed complete closure, and LAA patency was detected in 248 (47.8%) patients, including 196 (37.8%) with visible PDL and 52 (10.0%) without visible PDL. During a median of 1193 (787-1543) days follow-up, the presence of LAA patency was associated with increased risks of stroke/TIA (adjusted hazard ratio for baseline differences, 3.22 [95% CI, 1.17-8.83]; P=0.023) and MAEs (adjusted hazard ratio, 1.12 [95% CI, 1.06-1.17]; P=0.003). Specifically, LAA patency with visible PDL was associated with increased risks of stroke/TIA (hazard ratio, 3.66 [95% CI, 1.29-10.42]; P=0.015) and MAEs (hazard ratio, 3.71 [95% CI, 1.71-8.07]; P=0.001), although LAA patency without visible PDL showed higher risks of MAEs (hazard ratio, 3.59 [95% CI, 1.28-10.09]; P=0.015). Incidences of stroke/TIA (2.8% versus 3.0% versus 6.7% versus 22.2%; P=0.010), cardiovascular death (0.9% versus 0% versus 1.7% versus 11.1%; P=0.005), and MAEs (4.6% versus 9.0% versus 11.7% versus 22.2%; P=0.017) increased with larger PDL (0, >0 to ≤3, >3 to ≤5, or >5 mm). Older age and discontinuing antiplatelet therapy at 6 months were independent predictors of stroke/TIA and MAEs in patients with LAA patency. CONCLUSIONS: LAA patency detected by cardiac computed tomography angiography at 3 months post-LAA closure is associated with unfavorable prognosis in patients with atrial fibrillation implanted with WATCHMAN 2.5 device. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03788941.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Angiografia por Tomografia Computadorizada , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/fisiopatologia , Apêndice Atrial/diagnóstico por imagem , Masculino , Feminino , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/mortalidade , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/diagnóstico por imagem , Estudos Prospectivos , Fatores de Risco , Ataque Isquêmico Transitório/etiologia , Fatores de Tempo , Resultado do Tratamento , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Medição de Risco , Hemorragia , Desenho de Prótese
15.
Int Wound J ; 21(4): e14742, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38581265

RESUMO

Echocardiographic guidance in left atrial appendage (LAA) closure procedures is increasingly recognized for its potential to enhance patient outcomes in atrial fibrillation (AF). This retrospective study assesses its impact on hospital stay duration, readmission rates and surgical site wound complications in 200 AF patients. Divided equally into an echocardiographically guided group (Group E) and a non-guided group (Group N), the analysis focused on detailed patient data encompassing hospital stay, 30-day readmission and wound complications. Findings revealed that Group E experienced a significantly shorter average hospital stay of 3.5 days, compared with 6.5 days in Group N, along with a lower 30-day readmission rate (5% vs. 18% in Group N). Furthermore, Group E showed a considerable reduction in surgical site wound complications, such as infections and hematomas. The study concludes that echocardiographic guidance in LAA closure procedures markedly improves postoperative wound outcomes, underscoring its potential as a standard practice in cardiac surgeries for AF patients. This approach not only optimizes patient safety and postoperative recovery but also enhances healthcare resource utilization.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Estudos Retrospectivos , Oclusão do Apêndice Atrial Esquerdo , Resultado do Tratamento , Ecocardiografia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Complicações Pós-Operatórias/prevenção & controle , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia
16.
Catheter Cardiovasc Interv ; 103(7): 1152-1155, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38606476

RESUMO

The use of left atrial appendage occlusion (LAAO) devices have gained prominence as an alternative to long-term anticoagulation therapy in patients with atrial fibrillation at risk of stroke and high risk of bleeding. While these devices have shown efficacy in reducing stroke risk, there have been reported cases of embolization of the Watchman device. There are very few cases of successful percutaneous retrieval of embolized Watchman devices from the left ventricle (LV), as many of these cases require open heart surgery for safe removal. We are presenting a case of an 80-year-old male whose Watchman device embolized to the LV and was entrapped on the LV papillary muscle that was then successfully retrieved via percutaneous methods, which shows the percutaneous options remain a viable strategy to retrieve LAAO devices from the LV.


Assuntos
Fibrilação Atrial , Cateterismo Cardíaco , Remoção de Dispositivo , Migração de Corpo Estranho , Músculos Papilares , Humanos , Masculino , Idoso de 80 Anos ou mais , Resultado do Tratamento , Fibrilação Atrial/terapia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Migração de Corpo Estranho/terapia , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/diagnóstico por imagem , Músculos Papilares/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Embolia/etiologia , Embolia/diagnóstico por imagem , Embolia/terapia , Embolia/diagnóstico , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Ecocardiografia Transesofagiana
17.
Am J Cardiol ; 222: 87-94, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38642870

RESUMO

Intracardiac echocardiography (ICE) has emerged as an alternative to transesophageal echo (TEE) to guide left atrial appendage occlusion (LAAO). We established a protocol to select patients appropriate for ICE guidance. Patients who underwent LAAO with the Watchman or Watchman FLX device (Boston Scientific, Marlborough, Massachusetts) from January 2018 to March 2022 at a large United States center were included. The novel protocol prospectively selected TEE or ICE guidance beginning in January 2020; previous LAAO procedures were retrospectively included. ICE was selected for patients with uninterrupted anticoagulation and appropriate LAA anatomy, renal function, and moderate sedation tolerance. In-hospital outcomes with successful implantation without conversion to TEE guidance, no peridevice leak, and no procedural complications were compared. Composite 1-year outcome included freedom from peridevice leak, device-related thrombus, stroke, and all-cause mortality. A total of 234 patients were included; the mean age was 76.1 ± 8.3 years old, and 42.3% were female. ICE guidance was used for 63 procedures; TEE guidance was used for 171 procedures. For the composite outcome, ICE-guided LAAO was superior to TEE-guided LAAO (risk difference 0.102, 96.8% vs 86.5%, 95% confidence interval 0.003 to 0.203, p = 0.029). In comparison to the TEE-guided group, ICE-guided procedures were shorter (89.1 ± 26.3 vs 99.8 ± 30.0 min, p = 0.0087) with less general anesthesia (26.6% vs 98.8%, p <0.0001). One-year composite adverse outcomes did not differ significantly (80.7% vs 88.9%, p = 0.17). In conclusion, the protocol to select appropriate patients for ICE versus TEE guidance for LAAO is safe and effective. Larger studies are indicated to validate this approach to improve outcomes, shorten procedures, and avoid general anesthesia.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ecocardiografia Transesofagiana , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Feminino , Masculino , Ecocardiografia Transesofagiana/métodos , Idoso , Fibrilação Atrial/cirurgia , Protocolos Clínicos , Cateterismo Cardíaco/métodos , Estudos Retrospectivos , Ultrassonografia de Intervenção/métodos , Seleção de Pacientes , Idoso de 80 Anos ou mais , Cirurgia Assistida por Computador/métodos , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/epidemiologia , Ecocardiografia/métodos
19.
BMC Cardiovasc Disord ; 24(1): 175, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38515032

RESUMO

BACKGROUND: Approximately 90% of intracardial thrombi originate from the left atrial appendage in non-valvular atrial fibrillation patients. Even with anticoagulant therapy, left atrial appendage thrombus (LAAT) still occurs in 8% of patients. While left atrial appendage closure (LAAC) could be a promising alternative, the current consensus considers LAAT a contraindication to LAAC. However, the feasibility and safety of LAAC in patients with LAAT have yet to be determined. METHODS: This systematic review synthesizes published data to explore the feasibility and safety of LAAC for patients with LAAT. RESULTS: This study included a total of 136 patients with LAATs who underwent successful LAAC. The Amulet Amplatzer device was the most frequently utilized device (48.5%). Among these patients, 77 (56.6%) had absolute contraindications to anticoagulation therapy. Cerebral protection devices were utilized by 47 patients (34.6%). Transesophageal echocardiography (TEE) is the primary imaging technique used during the procedure. Warfarin and novel oral anticoagulants were the main anticoagulant medications used prior to the procedure, while dual antiplatelet therapy was primarily used post-procedure. During a mean follow-up period of 13.2 ± 11.5 months, there was 1 case of fatality, 1 case of stroke, 3 major bleeding events, 3 instances of device-related thrombus, and 8 cases of peri-device leakage. CONCLUSIONS: This review highlights the preliminary effectiveness and safety of the LAAC procedure in patients with persistent LAAT. Future large-scale RCTs with varied LAAT characteristics and LAAC device types are essential for evidence-based decision-making in clinical practice.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Trombose , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Oclusão do Apêndice Atrial Esquerdo , Apêndice Atrial/diagnóstico por imagem , Anticoagulantes/efeitos adversos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/tratamento farmacológico , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/prevenção & controle , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA