Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 880
Filtrar
1.
Iowa Orthop J ; 44(1): 99-103, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38919361

RESUMO

Background: Postoperative radiographs may be performed on different timelines after shoulder arthroplasty. Radiographs obtained in the post-operative recovery unit (PACU) are often of poorer quality. The purpose of the current study was to explore and compare the quality of PACU radiographs and radiographs performed in the radiology suite on post-operative Day 1 (POD1), as well as determine their impact on changes in post-operative management. Methods: Our series included 50 consecutive anatomic total shoulder arthroplasties (TSA) for which post-operative radiographs were obtained in the PACU and 50 consecutive TSA for which post-operative radiographs were obtained in the radiology suite on POD 1. TSA radiographs were blinded and reviewed by 3 authors and graded on their quality using criteria described using previously published methods. The weighted kappa was used to describe the intra-rater agreement and inter-rater agreement between two raters. Results: There was no difference in age, sex, BMI, and comorbidities between cohorts. Intra-observer reliability was moderate to substantial with weighted kappa values of 0.65±0.07 (p<0.001), 0.58±0.09 (p<0.001), and 0.67±0.07 (p<0.001). Inter-observer reliability was moderate to substantial with weighted kappa values of 0.605±0.07 (p<0.001), 0.66±0.07 (p<0.001), and 0.65±0.08 (p<0.001). When assessing quality of radiographs, 30% of radiographs obtained in PACU were deemed quality while 57% of radiographs obtained in the radiology suite were deemed quality (p<0.001). Conclusion: Post-operative radiographs in the PACU do not alter patient management and are often inadequate to serve as baseline radiographs. Conversely, radiographs obtained in the radiology suite are of higher quality and can serve as a superior baseline radiograph. Level of Evidence: IV.


Assuntos
Artroplastia do Ombro , Radiografia , Humanos , Artroplastia do Ombro/métodos , Masculino , Feminino , Radiografia/métodos , Idoso , Sala de Recuperação , Pessoa de Meia-Idade , Articulação do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem , Cuidados Pós-Operatórios , Período Pós-Operatório , Estudos Retrospectivos , Fatores de Tempo , Reprodutibilidade dos Testes
2.
BMC Musculoskelet Disord ; 25(1): 449, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844899

RESUMO

BACKGROUND: Patient-specific aiming devices (PSAD) may improve precision and accuracy of glenoid component positioning in total shoulder arthroplasty, especially in degenerative glenoids. The aim of this study was to compare precision and accuracy of guide wire positioning into different glenoid models using a PSAD versus a standard guide. METHODS: Three experienced shoulder surgeons inserted 2.5 mm K-wires into polyurethane cast glenoid models of type Walch A, B and C (in total 180 models). Every surgeon placed guide wires into 10 glenoids of each type with a standard guide by DePuy Synthes in group (I) and with a PSAD in group (II). Deviation from planned version, inclination and entry point was measured, as well as investigation of a possible learning curve. RESULTS: Maximal deviation in version in B- and C-glenoids in (I) was 20.3° versus 4.8° in (II) (p < 0.001) and in inclination was 20.0° in (I) versus 3.7° in (II) (p < 0.001). For B-glenoid, more than 50% of the guide wires in (I) had a version deviation between 11.9° and 20.3° compared to ≤ 2.2° in (II) (p < 0.001). 50% of B- and C-glenoids in (I) showed a median inclination deviation of 4.6° (0.0°-20.0°; p < 0.001) versus 1.8° (0.0°-4.0°; p < 0.001) in (II). Deviation from the entry point was always less than 5.0 mm when using PSAD compared to a maximum of 7.7 mm with the standard guide and was most pronounced in type C (p < 0.001). CONCLUSION: PSAD enhance precision and accuracy of guide wire placement particularly for deformed B and C type glenoids compared to a standard guide in vitro. There was no learning curve for PSAD. However, findings of this study cannot be directly translated to the clinical reality and require further corroboration.


Assuntos
Artroplastia do Ombro , Curva de Aprendizado , Humanos , Artroplastia do Ombro/métodos , Artroplastia do Ombro/instrumentação , Fios Ortopédicos , Cavidade Glenoide/cirurgia , Modelos Anatômicos , Articulação do Ombro/cirurgia
3.
Nan Fang Yi Ke Da Xue Xue Bao ; 44(5): 967-973, 2024 May 20.
Artigo em Chinês | MEDLINE | ID: mdl-38862455

RESUMO

OBJECTIVE: To develop the'E-Bone', a comprehensive one-stop preoperative planning system for reverse total shoulder arthroplasty with improved accuracy and efficiency. METHODS: The nnU-net deep neural network was utilized for scapula segmentation to obtain precise scapula segmentation results. Based on the 3 key factors, namely bone density, upward and downward angle and nail length, the base was automatically positioned. The quantitative parameters required for surgical planning were calculated. A personalized guide plate was generated by combining glenoid morphology and base positioning information. The system interface was developed to modularize various functions for easy use, providing interactive operation and real-time display. RESULTS: Compared with the Mimics system, the'E-bone'preoperative planning system reduced complex manual adjustments during the planning process. The average planned nail length was longer than that of the Mimics system, and the planning time was reduced by 86%. The scapula segmentation accuracy of this system reached 99.93%, better than that of Mimics to achieve a higher precision. CONCLUSION: The"E-bone"system provides a one-stop, efficient, and accurate preoperative planning system for reverse shoulder replacement and potentially broader clinical applications.


Assuntos
Artroplastia do Ombro , Humanos , Artroplastia do Ombro/métodos , Redes Neurais de Computação , Escápula/cirurgia , Cirurgia Assistida por Computador/métodos
4.
Acta Orthop ; 95: 348-357, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38888103

RESUMO

BACKGROUND AND PURPOSE: International variation exists in the types of shoulder replacement used for treatment of specific diseases. Implant choice continues to evolve without high-quality evidence. Our aim was to evaluate trends in incidence rates of shoulder replacement and assess any recent changes in practice between countries by using registry data. METHODS: Patient characteristics, indication and year of surgery, type of replacement, and collection methods of patient-reported outcomes (PROMs) was extracted from 11 public joint registries. Meta-analyses examined use of reverse total shoulder replacement (RTSR) for osteoarthritis, cuff tear arthropathy, and acute fracture; use of anatomical total shoulder replacement (TSR) for osteoarthritis; and use of humeral hemiarthroplasty for fracture. RESULTS: The annual growth rate of shoulder replacements performed is 6-15% (2011-2019). The use of RTSR has almost doubled (93%). RTSR is now universally performed for cuff tear arthropathy (97.3%, 95% confidence interval [CI] 96.0-98.1). Its use for avascular necrosis, trauma, and inflammatory arthropathy is increasing. The use of RTSR was similar (43.1%, CI 30.0-57.2) versus TSR (44.7%, CI 31.1-59.1) for osteoarthritis. The types of PROMs used, collection time points, and response rates lack standardization. COVID-19 had a varying inter-registry impact on incidence rates. CONCLUSION: The incidence of shoulder replacements has grown. Use of RTSR has increased for all disease indications despite limited high-quality evidence driving this change in indications outside of cuff arthropathy. Consequently, less variation is observed in international practice. Existing differences now relate to use of newer implant types and methodology of PROMs collection, which prevents international comparison and outcome analysis.


Assuntos
Artroplastia do Ombro , Sistema de Registros , Humanos , Artroplastia do Ombro/tendências , Artroplastia do Ombro/estatística & dados numéricos , Artroplastia do Ombro/métodos , Articulação do Ombro/cirurgia , Osteoartrite/cirurgia , Osteoartrite/epidemiologia , Artropatia de Ruptura do Manguito Rotador/cirurgia , Artropatia de Ruptura do Manguito Rotador/epidemiologia , Hemiartroplastia/tendências , Hemiartroplastia/métodos , Hemiartroplastia/estatística & dados numéricos
5.
J Bone Joint Surg Am ; 106(13): 1181-1188, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38758820

RESUMO

BACKGROUND: Controversy exists regarding the ideal humeral component version to optimize humeral rotation and patient outcomes in reverse total shoulder arthroplasty (rTSA). METHODS: Patients undergoing primary rTSA for rotator cuff tear arthropathy, a massive rotator cuff tear, or primary osteoarthritis with a rotator cuff tear were randomized to placement of the humeral component in neutral version or 30° of retroversion. Shoulder active range of motion and strength and visual analog scale (VAS) pain, American Shoulder and Elbow Surgeons (ASES), and Patient-Reported Outcomes Measurement Information System Global 10 (PROMIS-10) scores were collected up to 2 years postoperatively. The goal of the study was to determine whether humeral external rotation and internal rotation are affected by humeral component version following rTSA at 2 years postoperatively. RESULTS: Sixty-six patients were included in the analysis. The median follow-up was 26 months for the neutral and 27 months for the 30° retroversion group. No differences between the groups were observed with respect to the primary diagnosis, sex, age, body mass index, or American Society of Anesthesiologists (ASA) class. The 2 groups did not differ significantly in terms of improvement at 2 years in active shoulder abduction (p = 0.969), forward elevation (p = 1.000), internal rotation measured as the highest spinal level reached (p = 1.000), internal rotation with the arm abducted 90° (p = 0.451), external rotation (p = 0.362), or muscle strength in forward elevation (p = 1.000), abduction (p = 1.000), external rotation (p = 0.617), or internal rotation (p = 1.000). The 2 groups did not differ significantly in terms of improvement in postoperative ASES (p = 1.000), PROMIS-10 physical (p = 1.000), or VAS pain scores (p = 0.718) at the time of final follow-up. In the neutral version group, 1 patient underwent revision for instability and 1 for stiffness. One acromial stress fracture occurred in the 30° humeral retroversion group. Scapular notching was observed in 7 (21.2%) of the patients in neutral version group and 5 (15.2%) of the patients in the 30° retroversion group (p = 0.750). CONCLUSIONS: Securing the humeral component at neutral version or 30° of retroversion in rTSA resulted in similar active shoulder external rotation, internal rotation, forward elevation, abduction, and strength measurements, complication rates, and VAS pain, PROMIS-10 physical, and ASES scores at 2 years postoperatively. LEVEL OF EVIDENCE: Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia do Ombro , Amplitude de Movimento Articular , Humanos , Artroplastia do Ombro/métodos , Masculino , Feminino , Idoso , Estudos Prospectivos , Método Duplo-Cego , Pessoa de Meia-Idade , Resultado do Tratamento , Úmero/cirurgia , Lesões do Manguito Rotador/cirurgia , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Artropatia de Ruptura do Manguito Rotador/cirurgia , Osteoartrite/cirurgia , Osteoartrite/fisiopatologia , Prótese de Ombro , Medidas de Resultados Relatados pelo Paciente , Medição da Dor
6.
Int Orthop ; 48(7): 1815-1820, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38750258

RESUMO

PURPOSE: The purpose of this study is to identify risk factors for delays in planned total shoulder arthroplasty (TSA) and determine the perioperative outcomes of TSAs that experienced a delay. METHODS: The American College of Surgeons National Quality Improvement Program (NSQIP) database was queried from 2006 to 2019 for primary TSA. Delayed TSA was defined as surgery that occurred greater than one day after hospital admission. Patient demographics, comorbidities, and post-operative complications were collected and compared; the incidence of delayed TSA was analyzed. RESULTS: The delayed patients were older, had a higher BMI, a higher rate of recent prior major surgery, and more comorbidities. Delayed patients had higher rates of postoperative complications, return to the OR, and 30-day readmission. Between 2006 and 2019, the rate of delayed TSA decreased. CONCLUSION: Surgeons should take care to ensure that patients with comorbidities undergo thorough preoperative clearance to prevent same-day cancellations and postoperative complications.


Assuntos
Artroplastia do Ombro , Procedimentos Cirúrgicos Eletivos , Complicações Pós-Operatórias , Humanos , Artroplastia do Ombro/métodos , Artroplastia do Ombro/efeitos adversos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Procedimentos Cirúrgicos Eletivos/efeitos adversos , Procedimentos Cirúrgicos Eletivos/métodos , Fatores de Risco , Tempo para o Tratamento/estatística & dados numéricos , Resultado do Tratamento , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Comorbidade
7.
Orthop Clin North Am ; 55(3): 363-381, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38782508

RESUMO

The utilization of total shoulder arthroplasty (TSA) is increasing, driving associated annual health care costs higher. Opting for outpatient over inpatient TSA may provide a solution by reducing costs. However, there is no single set of accepted patient selection criteria for outpatient TSA. Here, the authors identify and systematically review 14 articles to propose evidence-based criteria that merit postoperative admission. Together, the studies suggest that patients with limited ability to abmluate independently or a history of congestive heart failure may benefit from postoperative at least one night of hospital based monitoring and treatment.


Assuntos
Artroplastia do Ombro , Seleção de Pacientes , Humanos , Artroplastia do Ombro/métodos , Procedimentos Cirúrgicos Ambulatórios
8.
Bull Hosp Jt Dis (2013) ; 82(2): 146-153, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38739663

RESUMO

Surgical management of the subscapularis tendon is critical to a successful outcome following anatomic total shoulder arthroplasty. However, the optimal surgical technique for adequate exposure of the glenohumeral joint while mini-mizing complications resulting from subscapularis tendon dysfunction continues to be controversial. Common surgical techniques for the management of the subscapularis tendon include tenotomy, peeling, sparing, and lesser tuberosity oste-otomy. Despite a number of published studies comparing these techniques, no consensus has been reached regarding optimal management. This article reviews the extensive literature on the biomechanical, radiologic, and clinical outcomes of each technique, including recently published comparison studies.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Artroplastia do Ombro/métodos , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Articulação do Ombro/diagnóstico por imagem , Resultado do Tratamento , Fenômenos Biomecânicos , Tenotomia/métodos , Recuperação de Função Fisiológica , Tendões/cirurgia , Amplitude de Movimento Articular
9.
BMC Musculoskelet Disord ; 25(1): 396, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773483

RESUMO

PURPOSE: This systematic review aims to provide an overview of the current knowledge on the role of the metaverse, augmented reality, and virtual reality in reverse shoulder arthroplasty. METHODS: A systematic review was performed using the PRISMA guidelines. A comprehensive review of the applications of the metaverse, augmented reality, and virtual reality in in-vivo intraoperative navigation, in the training of orthopedic residents, and in the latest innovations proposed in ex-vivo studies was conducted. RESULTS: A total of 22 articles were included in the review. Data on navigated shoulder arthroplasty was extracted from 14 articles: seven hundred ninety-three patients treated with intraoperative navigated rTSA or aTSA were included. Also, three randomized control trials (RCTs) reported outcomes on a total of fifty-three orthopedics surgical residents and doctors receiving VR-based training for rTSA, which were also included in the review. Three studies reporting the latest VR and AR-based rTSA applications and two proof of concept studies were also included in the review. CONCLUSIONS: The metaverse, augmented reality, and virtual reality present immense potential for the future of orthopedic surgery. As these technologies advance, it is crucial to conduct additional research, foster development, and seamlessly integrate them into surgical education to fully harness their capabilities and transform the field. This evolution promises enhanced accuracy, expanded training opportunities, and improved surgical planning capabilities.


Assuntos
Artroplastia do Ombro , Realidade Aumentada , Realidade Virtual , Humanos , Artroplastia do Ombro/métodos , Cirurgia Assistida por Computador/educação , Cirurgia Assistida por Computador/métodos , Articulação do Ombro/cirurgia
10.
Sports Med Arthrosc Rev ; 32(1): 17-21, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38695499

RESUMO

Rotator cuff tears are the most frequent shoulder injury in patients over 50 years old. Treatment of rotator cuff tears is individualized based on the age, demands, and symptoms of the patient. Nonoperative treatment may often be effective, especially in lower-demand or elderly patients. Surgical repair is indicated after failure of nonoperative treatment or in patients whose high-demand lifestyle requires full strength and function of the shoulder. In older patients, larger tears are less likely to heal and rotator cuff repair may not reliable. In cases of failed previous rotator cuff repair, there may not be enough viable tissue for complete repair. If there is underlying arthritis, a rotator cuff repair is unlikely to resolve all symptoms, and treatment to care for the arthritis and rotator cuff tear is indicated. Reverse shoulder arthroplasty provides the surgical answer for these scenarios and is now being used for numerous indications of shoulder pathology.


Assuntos
Artroplastia do Ombro , Lesões do Manguito Rotador , Humanos , Lesões do Manguito Rotador/cirurgia , Artroplastia do Ombro/métodos
12.
Eur J Orthop Surg Traumatol ; 34(4): 2137-2145, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38557891

RESUMO

PURPOSE: When compared to standard-length humeral stem in reverse total shoulder arthroplasty (RTSA), short humeral stems in RTSA require good proximal humeral metaphyseal bone quality to gain proper and secure fixation during prosthetic implantation. Shorter humeral stems potentially carry more risk of misalignment than standard or long humeral stems. The hypothesis was that misalignment of the short humeral stems is influenced by regional bone quality. METHODS: RTSA with a short curved humeral stem with neck-shaft angle (NSA) default of 132.5° was reviewed. The study group included 35 cases at a mean age of 75.97 (± 6.23) years. Deltoid-tuberosity index (DTI) was measured to evaluate proximal humeral bone quality. The deltoid tuberosity index was measured at immediately above position of the upper end of the deltoid tuberosity. Stem alignment was given by the angle measured in degrees between the intramedullary humeral shaft axis and the axis of the humeral implant stem. RESULTS: The patient's mean DTI was 1.37 ± 0.16 (median, 1.32; range, 1.12-1.80). 22 patients had poor bone quality (DTI < 1.4), compared to 13 patients with acceptable bone quality (DTI > 1.4). After RTSA, ten humeral components (29%) were neutrally aligned, whereas 25 humeral components (71%) were misaligned. There was no correlation between misalignment and DTI (r = 0.117; p = 0.504). But there was a strong correlation between misalignment and the patient's own NSA (r = - 0.47; p = 0.004). The postoperative stem position and stem misalignment are not associated with functional outcomes (p > 0.05). CONCLUSION: The misalignment of the short curved humeral stem frequently occurs. Poor reginal humeral bone quality does not influence misalignment after RTSA with a short humeral stem. Postoperative stem alignment is associated with the patient's preoperative NSA and method of neck cut. The misalignment does not affect functional outcomes for midterm follow-up. Further long-term follow-up studies are needed to confirm its clinical relevance.


Assuntos
Artroplastia do Ombro , Úmero , Desenho de Prótese , Prótese de Ombro , Humanos , Artroplastia do Ombro/métodos , Artroplastia do Ombro/efeitos adversos , Idoso , Úmero/cirurgia , Úmero/diagnóstico por imagem , Masculino , Feminino , Prótese de Ombro/efeitos adversos , Idoso de 80 Anos ou mais , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Estudos Retrospectivos
13.
Eur J Orthop Surg Traumatol ; 34(4): 2193-2200, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38578440

RESUMO

INTRODUCTION: Revision shoulder arthroplasty can be challenging. One of the main considerations for surgeons is the type of implant that was placed in the initial surgery. Anatomic shoulder arthroplasty (ASA) is used for cases of osteoarthritis as well as for fractures of the humeral head. Hemiarthroplasty can be used for complex proximal humerus fractures. The purpose of this study is to determine whether there is a difference in clinical and radiographic outcomes between patients that failed primary fracture hemiarthroplasty (FHA), or ASA for osteoarthritis and then required reoperation with a conversion to reverse shoulder arthroplasty (RSA). METHODS: Patients with failed anatomic shoulder replacement, who had undergone conversion to RSA, were enrolled after a mean follow-up of 107 (85-157) months. Two different groups, one with failed ASA implanted for osteoarthritis and one with failed FHA, were created. At follow-up patients were assessed with standard radiographs and clinical outcome scores. RESULTS: Twenty-nine patients (f = 17, m = 12; 51%) suffered from a failed ASA (Group A), while the remaining 28 patients (f = 21, m = 74; 49%) had been revised due to a failed FHA (Group B). Patients of Group B had a poorer Constant score (Group A: 60 vs. Group B: 46; p = 0.02). Abduction (Group A: 115° vs. Group B: 89°; p = 0.02) was worse after conversion of a failed FHA to RSA in comparison to conversions of failed ASA. The mean bone loss of the lateral metaphysis was higher in patients with failed FHA (Group A: 5 mm vs. Group B: 20 mm; p = 0.0). CONCLUSION: The initial indication for anatomic shoulder arthroplasty influences the clinical and radiological outcome after conversion to RSA. Conversion of failed FHA to RSA is related to an increased metaphyseal bone loss, decreased range of motion and poorer clinical outcomes when compared to conversions of failed ASA implanted for osteoarthritis. LEVEL OF EVIDENCE: III Retrospective Cohort Comparison Study.


Assuntos
Artroplastia do Ombro , Hemiartroplastia , Osteoartrite , Radiografia , Reoperação , Fraturas do Ombro , Articulação do Ombro , Humanos , Artroplastia do Ombro/métodos , Hemiartroplastia/métodos , Masculino , Feminino , Idoso , Reoperação/estatística & dados numéricos , Reoperação/métodos , Osteoartrite/cirurgia , Osteoartrite/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Fraturas do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Pessoa de Meia-Idade , Resultado do Tratamento , Idoso de 80 Anos ou mais , Amplitude de Movimento Articular , Seguimentos , Estudos Retrospectivos
14.
Arch Orthop Trauma Surg ; 144(5): 2093-2099, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38653836

RESUMO

OBJECTIVE: The objective of this study was to evaluate clinical and radiological outcomes of a short stem reverse shoulder prosthesis with metaphyseal fixation specifically in older patients. METHODS: All patients, older than 70 years, submitted to a Reverse Shoulder Arthroplasty (RSA) using a cementless onlay short stem (Aequalis Ascend™ Flex Convertible Shoulder System (Stryker®)) from January 2017 to December 2021, with a minimum follow-up of 2 years, were included. Postoperative radiographs were assessed for stem loosening, subsidence, and varus-valgus tilt. Range of motion, visual analogue scale for pain, constant score, complication rate and revision rate were also analysed. RESULTS: A total of 34 patients with a mean age of 75 years (range 71-83 years) were submitted to a cementless onlay short stem RSA with a Bone Increased Off-Set (BIO-RSA) construct. The mean follow-up period was 61 months (range 54-87). Significant improvements (p < 0.001) were observed for the constant score and range of motion from the preoperative state to final follow-up. One case exhibited a significant varus deviation (> 5˚) during the follow-up period. No case of stem loosening was identified. There was only one case of complication because of post-traumatic dislocation, but the stem didn't need revision. CONCLUSION: Short stem RSA, even in patients older than 70 years, can yield a stable fixation with a good clinical and radiological outcome at short-medium term follow-up. LEVEL OF EVIDENCE: Level III; Retrospective Study.


Assuntos
Artroplastia do Ombro , Desenho de Prótese , Prótese de Ombro , Humanos , Idoso , Artroplastia do Ombro/métodos , Idoso de 80 Anos ou mais , Feminino , Masculino , Amplitude de Movimento Articular , Estudos Retrospectivos , Radiografia , Resultado do Tratamento , Articulação do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem
15.
Orthop Surg ; 16(6): 1277-1283, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38627352

RESUMO

OBJECTIVE: Primary joint arthroplasty (JA) is one of the most common operating room (OR) procedures, with knee and hip arthroplasties being listed in the top five most frequent OR procedures and while not as common, shoulder arthroplasties are increasing at greater rates than knee and hip arthroplasties. Periprosthetic joint/shoulder infections (PJI/PSI) are a devastating complication of primary JAs with infection prevention deemed as the single most important strategy in combating them. The objective of this study was to retrospectively evaluate the efficacy of XPERIENCE® Advanced Surgical Irrigation (XP) in preventing PJI following primary joint arthroplasty. METHODS: This is a retrospective study of primary knee, hip and shoulder arthroplasties that were performed by multiple orthopedic surgeons at a single hospital setting. XPERIENCE was used as an intraoperative surgical irrigant either solely, or with other intraoperative practices for prevention of infection. Incidence of acute PJI occurring within 90 days of index surgery were retrospectively collated. RESULTS: Four hundred and twenty-three (423) primary joint replacement surgeries treated intraoperatively with XP, were evaluated for acute PJI incidence. Retrospective evaluations determined that 95% of the subjects had at least one risk factor predisposing them to PJI. There were zero PJIs diagnosed in the knee and hip arthroplasty cohorts and zero PSIs diagnosed in the shoulder arthroplasty cohorts. CONCLUSION: The absence of PJI/PSI diagnoses in the JA cohorts treated intraoperatively with XP indicates that it could be an efficacious antimicrobial irrigant in preventing PJI, and warrants being evaluated in prospective, randomized controlled clinical trials as the sole intraoperative irrigant, as well as in combination with the other intraoperative infection prevention regimens evaluated in this retrospective study.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Artroplastia do Ombro , Cuidados Intraoperatórios , Infecções Relacionadas à Prótese , Irrigação Terapêutica , Humanos , Estudos Retrospectivos , Infecções Relacionadas à Prótese/prevenção & controle , Masculino , Feminino , Irrigação Terapêutica/métodos , Idoso , Pessoa de Meia-Idade , Artroplastia do Ombro/métodos , Cuidados Intraoperatórios/métodos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Artroplastia de Quadril/métodos , Artroplastia de Quadril/efeitos adversos , Idoso de 80 Anos ou mais , Adulto
16.
J Orthop Traumatol ; 25(1): 20, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637350

RESUMO

BACKGROUND: This study aims to compare the range of motion (ROM) of reverse shoulder arthroplasty lateralised by bony increased offset (BIO-RSA) using a standard 38-mm (mm) component to regular reverse shoulder arthroplasty (RSA) lateralised by using a 42-mm glenoid component. The secondary aims are to compare patient-reported and radiographic outcomes between the two groups. MATERIALS AND METHODS: All patients with a BIO-RSA and size 38 glenosphere were retrospectively identified and matched to patients with a regular RSA and size 42 glenosphere. Matched patients were invited for a follow-up visit. ROM was assessed as well as radiographic outcomes (lateralisation, distalisation, inferior overhang, scapular notching, heterotopic bone formation, radiolucency, stress shielding, bone graft healing and viability and complications) and patient-reported outcomes (subjective shoulder value, Constant score, American Shoulder and Elbow Surgeons, activities of daily living which require internal rotation, activities of daily living which require external rotation and a visual analogue scale for pain). Outcomes were compared between the two groups. RESULTS: In total, 38 BIO-RSAs with a size 38 glenosphere were matched to 38 regular RSAs with a size 42 glenosphere. Of the 76 matched patients, 74 could be contacted and 70 (95%) were included. At the final follow-up, there were no differences between the two groups in ROM, patient-reported outcomes or radiographic outcomes (p > 0.485). CONCLUSIONS: Using a larger glenosphere is a feasible alternative to BIO-RSA for lateralising RSA, providing comparable ROM, patient-reported and radiographic results, while potentially decreasing costs, operative time and complication rates.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Artroplastia do Ombro/métodos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Estudos Retrospectivos , Atividades Cotidianas , Escápula/diagnóstico por imagem , Escápula/cirurgia , Amplitude de Movimento Articular , Resultado do Tratamento
17.
Bone Joint J ; 106-B(5): 482-491, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38688478

RESUMO

Aims: Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey. Methods: NJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact rotator cuff were included. Metal and ceramic humeral head prostheses were matched within separate TSA and HA groups using propensity scores based on 12 and 11 characteristics, respectively. The primary outcome was time to first revision and the secondary outcome was non-revision reoperation. Results: A total of 4,799 TSAs (3,578 metal, 1,221 ceramic) and 1,363 HAs (1,020 metal, 343 ceramic) were included. The rate of revision was higher for metal compared with ceramic TSA, hazard ratio (HR) 3.31 (95% confidence interval (CI) 1.67 to 6.58). At eight years, prosthesis survival for ceramic TSA was 98.7% (95% CI 97.3 to 99.4) compared with 96.4% (95% CI 95.2 to 97.3) for metal TSA. The majority of revision TSAs were for cuff insufficiency or instability/dislocation. There was no significant difference in the revision rate for ceramic compared with metal head HA (HR 1.33 (95% CI 0.76 to 2.34)). For ceramic HA, eight-year prosthetic survival was 92.8% (95% CI 86.9 to 96.1), compared with 91.6% (95% CI 89.3 to 93.5) for metal HA. The majority of revision HAs were for cuff failure. Conclusion: The rate of all-cause revision was higher following metal compared with ceramic humeral head TSA in patients with OA and an intact rotator cuff. There was no difference in the revision rate for HA according to bearing surface.


Assuntos
Artroplastia do Ombro , Cerâmica , Hemiartroplastia , Desenho de Prótese , Falha de Prótese , Reoperação , Prótese de Ombro , Humanos , Reoperação/estatística & dados numéricos , Hemiartroplastia/métodos , Masculino , Feminino , Artroplastia do Ombro/métodos , Idoso , Pessoa de Meia-Idade , Osteoartrite/cirurgia , Sistema de Registros , Cabeça do Úmero/cirurgia , Idoso de 80 Anos ou mais , Metais
18.
Clin Orthop Surg ; 16(2): 303-312, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562639

RESUMO

Background: Glenoid position and inclination are important factors in protecting against scapular notching, which is the most common complication that directly affects the longevity of reverse shoulder arthroplasty (RSA). This study aimed to investigate the biomechanical characteristics of glenosphere orientation, comparing neutral tilt, inferior overhang with an eccentric glenosphere at the same placement of baseplate, and inferior tilt after 10° inferior reaming in the lower part of the glenoid in RSA. Methods: Nine cadaveric shoulders were tested with 5 combinations of customized glenoid components: a centric glenosphere was combined with a standard baseplate (group A); an eccentric glenosphere to provide 4-mm inferior overhang than the centric glenosphere was combined with a standard baseplate (group B); a centric glenosphere was combined with a wedge-shaped baseplate tilted inferiorly by 10° with the same center of rotation (group C); an eccentric glenosphere was attached to a wedge-shaped baseplate (group D); and 10° inferior reaming was performed on the lower part of the glenoid to apply 10° inferior tilt, with a centric glenosphere secured to the standard baseplate for simulation of clinical tilt (group E). Impingement-free angles for adduction, abduction, forward flexion, external rotation, and internal rotation were measured. The capability of the deltoid moment arm for abduction and forward flexion, deltoid length, and geometric analysis for adduction engagement were evaluated. Results: Compared with neutral tilt, inferior tilt at the same position showed no significant difference in impingement-free angle, moment arm capability, and deltoid length. However, group D resulted in better biomechanical properties than a central position, regardless of inferior tilt. Group E demonstrated a greater range of adduction, internal and external rotation, and higher abduction and forward flexion capability with distalization, compared to corresponding parameters for inferior tilt with a customized wedge-shaped baseplate. Conclusions: A 10° inferior tilt of the glenosphere, without changing the position of the baseplate, had no benefit in terms of the impingement-free angle and deltoid moment arm. However, an eccentric glenosphere had a significant advantage, regardless of inferior tilt. Inferior tilt through 10° inferior reaming showed better biomechanical results than neutral tilt due to the distalization effect.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Humanos , Artroplastia do Ombro/métodos , Articulação do Ombro/cirurgia , Ombro/cirurgia , Escápula , Amplitude de Movimento Articular , Fenômenos Biomecânicos
19.
Acta Orthop Belg ; 90(1): 115-122, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38669660

RESUMO

The introduction of fast-track protocols decreased length of hospital stay and improved rehabilitation and outcomes in total joint arthroplasty. Despite improved clinical results published in many papers, the patient perspective of these protocols is less investigated. Purpose of this study was to explore the patient perspective of fast-track protocols in arthroplasty. A systematic search for articles of patient experiences in total hip, knee, and shoulder arthroplasty was conducted using EMBASE, MEDLINE, Cochrane, and Web-of-Science for articles published from inception to February 14, 2023. In total 12 studies were included involving 672 patients. Most patients were satisfied with short length of hospital stay and preferred rehabilitation at home with relatives for support. Various experiences were reported regarding pain and postoperative out of hospital physical therapy. Frequently, feelings of insecurity were reported because of lack of personalized information. Based on current qualitative literature, patients are satisfied with short length of hospital stay in fast-track total joint arthroplasty. Improvements in personalized information and physical therapy protocols is needed.


Assuntos
Tempo de Internação , Satisfação do Paciente , Humanos , Tempo de Internação/estatística & dados numéricos , Artroplastia de Quadril/reabilitação , Artroplastia de Quadril/métodos , Artroplastia do Joelho/reabilitação , Artroplastia do Joelho/métodos , Artroplastia de Substituição/métodos , Artroplastia do Ombro/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...