Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 960
Filtrar
1.
Korean J Radiol ; 25(7): 673-683, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38942461

RESUMO

OBJECTIVE: To evaluate the role of visual and quantitative chest CT parameters in assessing treatment response in patients with severe asthma. MATERIALS AND METHODS: Korean participants enrolled in a prospective multicenter study, named the Precision Medicine Intervention in Severe Asthma study, from May 2020 to August 2021, underwent baseline and follow-up chest CT scans (inspiration/expiration) 10-12 months apart, before and after biologic treatment. Two radiologists scored bronchiectasis severity and mucus plugging extent. Quantitative parameters were obtained from each CT scan as follows: normal lung area (normal), air trapping without emphysema (AT without emph), air trapping with emphysema (AT with emph), and airway (total branch count, Pi10). Clinical parameters, including pulmonary function tests (forced expiratory volume in 1 s [FEV1] and FEV1/forced vital capacity [FVC]), sputum and blood eosinophil count, were assessed at initial and follow-up stages. Changes in CT parameters were correlated with changes in clinical parameters using Pearson or Spearman correlation. RESULTS: Thirty-four participants (female:male, 20:14; median age, 50.5 years) diagnosed with severe asthma from three centers were included. Changes in the bronchiectasis and mucus plugging extent scores were negatively correlated with changes in FEV1 and FEV1/FVC (ρ = from -0.544 to -0.368, all P < 0.05). Changes in quantitative CT parameters were correlated with changes in FEV1 (normal, r = 0.373 [P = 0.030], AT without emph, r = -0.351 [P = 0.042]), FEV1/FVC (normal, r = 0.390 [P = 0.022], AT without emph, r = -0.370 [P = 0.031]). Changes in total branch count were positively correlated with changes in FEV1 (r = 0.349 [P = 0.043]). There was no correlation between changes in Pi10 and the clinical parameters (P > 0.05). CONCLUSION: Visual and quantitative CT parameters of normal, AT without emph, and total branch count may be effective for evaluating treatment response in patients with severe asthma.


Assuntos
Asma , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Asma/diagnóstico por imagem , Asma/fisiopatologia , Asma/tratamento farmacológico , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Estudos Prospectivos , Adulto , Resultado do Tratamento , Testes de Função Respiratória , Idoso
2.
J Perinat Med ; 52(6): 604-610, 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-38756079

RESUMO

OBJECTIVES: To compare fetal pulmonary artery Doppler parameters between pregnant women with asthma and healthy pregnant women. METHODS: This prospective, cross-sectional study was conducted on 50 pregnant women diagnosed with asthma and 61 healthy pregnant women. Fetal pulmonary artery Doppler parameters and the fetal main pulmonary artery acceleration time/ejection time (PATET) ratio were compared between the study and control groups. Thereafter, the study group was divided into two subgroups as non-severe and severe asthma. PATET ratio was compared between the subgroups. RESULTS: The fetal main pulmonary artery acceleration time was 25 ms in pregnant women with asthma and 33 ms in the healthy group, indicating a statistically significant difference (p=0.001). The acceleration time/ejection time ratio was statistically lower in the asthma group (0.185 vs. 0.240, p<0.001). The acceleration time/ejection time ratio was 0.172 in patients with severe asthma and 0.195 ms in the non-severe study group (p=0.156). In the maternal asthma group, the PATET ratio of those who went to the NICU due to respiratory distress was also 0.188, and the PATET ratio of those who went to the NICU for other reasons was 0.269 (p=0.053). CONCLUSIONS: Fetal pulmonary artery acceleration time and PATET decreased statistically in pregnant women with severe or non-severe asthma. Maternal asthma is associated with changes in pulmonary Doppler parameters in the fetus.


Assuntos
Asma , Artéria Pulmonar , Ultrassonografia Pré-Natal , Humanos , Feminino , Gravidez , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Asma/fisiopatologia , Asma/diagnóstico por imagem , Asma/complicações , Estudos de Casos e Controles , Ultrassonografia Pré-Natal/métodos , Adulto , Estudos Transversais , Estudos Prospectivos , Complicações na Gravidez/fisiopatologia , Complicações na Gravidez/diagnóstico por imagem , Ultrassonografia Doppler/métodos
3.
Med Phys ; 51(4): 2413-2423, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38431967

RESUMO

BACKGROUND: Individuals with asthma can vary widely in clinical presentation, severity, and pathobiology. Hyperpolarized xenon-129 (Xe129) MRI is a novel imaging method to provide 3-D mapping of both ventilation and gas exchange in the human lung. PURPOSE: To evaluate the functional changes in adults with asthma as compared to healthy controls using Xe129 MRI. METHODS: All subjects (20 controls and 20 asthmatics) underwent lung function measurements and Xe129 MRI on the same day. Outcome measures included the pulmonary ventilation defect and transfer of inspired Xe129 into two soluble compartments: tissue and blood. Ten asthmatics underwent Xe129 MRI before and after bronchodilator to test whether gas transfer measures change with bronchodilator effects. RESULTS: Initial analysis of the results revealed striking differences in gas transfer measures based on age, hence we compared outcomes in younger (n = 24, ≤ 35 years) versus older (n = 16, > 45 years) asthmatics and controls. The younger asthmatics exhibited significantly lower Xe129 gas uptake by lung tissue (Asthmatic: 0.98% ± 0.24%, Control: 1.17% ± 0.12%, P = 0.035), and higher Xe129 gas transfer from tissue to the blood (Asthmatic: 0.40 ± 0.10, Control: 0.31% ± 0.03%, P = 0.035) than the younger controls. No significant difference in Xe129 gas transfer was observed in the older group between asthmatics and controls (P > 0.05). No significant change in Xe129 transfer was observed before and after bronchodilator treatment. CONCLUSIONS: By using Xe129 MRI, we discovered heterogeneous alterations of gas transfer that have associations with age. This finding suggests a heretofore unrecognized physiological derangement in the gas/tissue/blood interface in young adults with asthma that deserves further study.


Assuntos
Asma , Broncodilatadores , Adulto Jovem , Humanos , Adulto , Broncodilatadores/uso terapêutico , Barreira Alveolocapilar , Pulmão/diagnóstico por imagem , Asma/diagnóstico por imagem , Asma/tratamento farmacológico , Isótopos de Xenônio , Imageamento por Ressonância Magnética/métodos , Xenônio/uso terapêutico
4.
Sci Rep ; 14(1): 5492, 2024 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-38448648

RESUMO

This study compared computational fluid dynamic (CFD) model predictions on aerosol deposition in six asthmatic patients to the in-vivo results of the same group. Patient-specific ventilation and internal air distribution were prescribed using inspiratory and expiratory CT scans of each patient, accounting for individual lobar air flow distribution. Moreover, the significant influence of realistic mouth and throat geometries on regional deposition is demonstrated. The in-vivo data were obtained from single photon emission computed tomography (SPECT) in 6 subjects with mild asthma selected from a database of historical clinical trials. The governing flow and particle tracking equations were solved numerically using a commercial CFD tool, and the modeled deposition results were compared to the SPECT data. Good agreement was found between the CFD model, applying k-ω SST turbulence model, and SPECT in terms of aerosol deposition. The average difference for the lobar deposition obtained from CFD model and SPECT/CT data was 2.1%. The high level of agreement is due to applying patient specific airway geometries and inspiratory/expiratory CT images, anatomical upper airways, and realistic airway trees. The results of this study show that CFD is a powerful tool to simulate patient-specific deposition if correct boundary conditions are applied and can generate similar information obtained with functional imaging tools, such as SPECT.


Assuntos
Asma , Laringe , Humanos , Hidrodinâmica , Tomografia Computadorizada de Emissão de Fóton Único , Nariz , Asma/diagnóstico por imagem , Aerossóis e Gotículas Respiratórios
5.
Respir Med ; 225: 107598, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38499273

RESUMO

BACKGROUND: Symptom perception and quality of life (QOL) are important domains for properly managing severe asthma. This study aimed to assess the relationship between airway structural and parenchymal variables measured using chest computed tomography (CT) and subjective symptom perception and QOL in patients with severe asthma enrolled in the Korean Severe Asthma Registry. METHODS: This study used CT-based objective measurements, including airway wall thickness (WT), hydraulic diameter, functional small airway disease (fSAD), and emphysematous lung (Emph), to assess their association with subjective symptom (cough, dyspnea, wheezing, and sputum) perception measured using the visual analog scale, and QOL measured by the Severe Asthma Questionnaire (SAQ). RESULTS: A total of 94 patients with severe asthma were enrolled in this study. The WT and fSAD% were significantly positively associated with cough and dyspnea, respectively. For QOL, WT and Emph% showed significant negative associations with the SAQ. However, there was no significant association between lung function and symptom perception or between lung function and QOL. CONCLUSION: Overall, WT, fSAD%, and Emph% measured using chest CT were associated with subjective symptom perception and QOL in patients with severe asthma. This study provides a basis for clarifying the clinical correlates of imaging-derived metrics and for understanding the mechanisms of respiratory symptom perception.


Assuntos
Asma , Enfisema , Doença Pulmonar Obstrutiva Crônica , Humanos , Qualidade de Vida , Asma/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Dispneia/etiologia , Tosse/etiologia , Percepção
6.
Allergol Int ; 73(3): 397-405, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38403524

RESUMO

BACKGROUND: Associations of fractional exhaled nitric oxide (FeNO) with airway wall remodeling and mucus plugs remain to be explored in smokers and nonsmokers with asthma. Ultra-high-resolution computed tomography (U-HRCT), which allows accurate structural quantification of airways >1 mm in diameter, was used in this study to examine whether higher FeNO was associated with thicker walls of the 3rd to 6th generation airways and mucus plugging in patients with asthma. METHODS: The retrospective analyses included consecutive former smokers and nonsmokers with asthma who underwent U-HRCT in a hospital. The ratio of wall area to summed lumen and wall area was calculated as the wall area percent (WA%). Mucus plugging was visually scored. RESULTS: Ninety-seven patients with asthma (including 59 former smokers) were classified into low (<20 ppb), middle (20-35 ppb), and high (>35 ppb) FeNO groups (n = 24, 26, and 47). In analysis including all patients and subanalysis including nonsmokers or former smokers, WA% in the 6th generation airways was consistently higher in the high FeNO group than in the low FeNO group, whereas WA% in the 3rd to 5th generation airways was not. In multivariable models, WA% in the 6th generation airways and the rate of mucus plugging were higher in the high FeNO group than in the low FeNO group after adjusting for age, sex, body mass index, smoking status, lung volume, and allergic rhinitis presence. CONCLUSIONS: Higher FeNO may reflect the inflammation and remodeling of relatively peripheral airways in asthma in both former smokers and nonsmokers.


Assuntos
Asma , Muco , Óxido Nítrico , Fumantes , Tomografia Computadorizada por Raios X , Humanos , Asma/metabolismo , Asma/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Óxido Nítrico/metabolismo , Muco/metabolismo , Adulto , Estudos Retrospectivos , Idoso , não Fumantes , Expiração , Remodelação das Vias Aéreas , Fumar/efeitos adversos , Teste da Fração de Óxido Nítrico Exalado , Testes Respiratórios/métodos
7.
Psychophysiology ; 61(5): e14513, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38339852

RESUMO

Little is known about central nervous system (CNS) responses to emotional stimuli in asthma. Nitric oxide in exhaled breath (FENO) is elevated in asthma due to allergic immune processes, but endogenous nitric oxide is also known to modulate CNS activity. We measured fMRI blood oxygen-dependent (BOLD) brain activation to negative (blood-injection-injury themes) and neutral films in 31 participants (15 with asthma). Regions-of-interest analysis was performed on key areas relevant to central adaptive control, threat processing, or salience networks, with dorsolateral prefrontal cortex (PFC), anterior insula, dorsal anterior cingulate cortex (dACC), amygdala, ventral striatum, ventral tegmentum, and periaqueductal gray, as well as top-down modulation of emotion, with ventrolateral and ventromedial PFC. Both groups showed less BOLD deactivation from fixation cross-baseline in the left anterior insula and bilateral ventromedial PFC for negative than neutral films, and for an additional number of areas, including the fusiform gyrus, for film versus recovery phases. Less deactivation during films followed by less recovery from deactivation was found in asthma compared to healthy controls. Changes in PCO2 did not explain these findings. FENO was positively related to BOLD activation in general, but more pronounced in healthy controls and more likely in neutral film processing. Thus, asthma is associated with altered processing of film stimuli across brain regions not limited to central adaptive control, threat processing, or salience networks. Higher levels of NO appear to facilitate CNS activity, but only in healthy controls, possibly due to allergy's masking effects on FENO.


Assuntos
Asma , Imageamento por Ressonância Magnética , Humanos , Óxido Nítrico/análise , Oxigênio , Asma/diagnóstico por imagem , Emoções/fisiologia
8.
NMR Biomed ; 37(6): e5121, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38423986

RESUMO

Although hyperpolarized (HP) 129Xe ventilation MRI can be carried out within a breath hold, it is still challenging for many sick patients. Compressed sensing (CS) is a viable alternative to accelerate this approach. However, undersampled images with identical sampling ratios differ from one another. Twenty subjects (n = 10 healthy and n = 10 patients with asthma) were scanned using a GE MR750 3 T scanner, acquiring fully sampled 2D multi-slice HP 129Xe lung ventilation images (10 s breath hold, 128 × 80 (FE × PE-frequency encoding × phase encoding) and 16 slices). Using fully sampled data, 500 variable-density Cartesian random undersampling patterns were generated, each at eight different sampling ratios from 10% to 80%. The parallel imaging and compressed sensing (PICS) command from BART was employed to reconstruct undersampled data. The signal to noise ratio (SNR), structural similarity index measurement (SSIM) and sidelobe to peak ratio of each were subsequently compared. There was a high degree of variation in both SNR and SSIM results from each of the 500 masks of each sampling rate. As the undersampling increases, there is more variation in the quantifying metrics, for both healthy and asthmatic individuals. Our study shows that random undersampling poses a significant challenge when applied at sampling ratios less than 60%, despite fulfilling CS's incoherency criteria. Such low sampling ratios will result in a large variety of undersampling patterns. Therefore, skipped segments of k-space cannot be allowed to happen randomly at low sampling rates. By optimizing the sampling pattern, CS will reach its full potential and be able to be applied to a highly undersampled 129Xe lung dataset.


Assuntos
Pulmão , Imageamento por Ressonância Magnética , Razão Sinal-Ruído , Isótopos de Xenônio , Humanos , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem , Masculino , Feminino , Adulto , Asma/diagnóstico por imagem , Pessoa de Meia-Idade , Compressão de Dados
10.
Chest ; 165(6): 1307-1318, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38387646

RESUMO

BACKGROUND: One of the major challenges in managing allergic bronchopulmonary aspergillosis remains consistent and reproducible assessment of response to treatment. RESEARCH QUESTION: What are the most relevant changes in CT scan parameters over time for assessing response to treatment? STUDY DESIGN AND METHODS: In this ancillary study of a randomized clinical trial (NebuLamB), patients with asthma with available CT scan and without exacerbation during a 4-month allergic bronchopulmonary aspergillosis exacerbation treatment period (corticosteroids and itraconazole) were included. Changed CT scan parameters were assessed by systematic analyses of CT scan findings at initiation and end of treatment. CT scans were assessed by two radiologists anonymized to the clinical data. Radiologic parameters were determined by selecting those showing significant changes over time. Improvement of at least one, without worsening of the others, defined the radiologic response. Agreement between radiologic changes and clinical and immunologic responses was likewise investigated. RESULTS: Among the 139 originally randomized patients, 132 were included. We identified five CT scan parameters showing significant changes at end of treatment: mucoid impaction extent, mucoid impaction density, centrilobular micronodules, consolidation/ground-glass opacities, and bronchial wall thickening (P < .05). These changes were only weakly associated with one another, except for mucoid impaction extent and density. No agreement was observed between clinical, immunologic, and radiologic responses, assessed as an overall response, or considering each of the parameters (Cohen κ, -0.01 to 0.24). INTERPRETATION: Changes in extent and density of mucoid impaction, centrilobular micronodules, consolidation/ground-glass opacities, and thickening of the bronchial walls were found to be the most relevant CT scan parameters to assess radiologic response to treatment. A clinical, immunologic, and radiologic multidimensional approach should be adopted to assess outcomes, probably with a composite definition of response to treatment. TRIAL REGISTRATION: ClinicalTrials.gov; No.: NCT02273661; URL: www. CLINICALTRIALS: gov).


Assuntos
Antifúngicos , Aspergilose Broncopulmonar Alérgica , Asma , Itraconazol , Tomografia Computadorizada por Raios X , Humanos , Aspergilose Broncopulmonar Alérgica/diagnóstico por imagem , Aspergilose Broncopulmonar Alérgica/tratamento farmacológico , Masculino , Feminino , Tomografia Computadorizada por Raios X/métodos , Asma/diagnóstico por imagem , Asma/tratamento farmacológico , Adulto , Pessoa de Meia-Idade , Itraconazol/uso terapêutico , Antifúngicos/uso terapêutico , Resultado do Tratamento , Corticosteroides/uso terapêutico
11.
Physiol Rep ; 12(1): e15909, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38185478

RESUMO

Asthma with fixed airway obstruction (FAO) is associated with significant morbidity and rapid decline in lung function, making its treatment challenging. Quantitative computed tomography (QCT) along with data postprocessing is a useful tool to obtain detailed information on airway structure, parenchymal function, and computational flow features. In this study, we aim to identify the structural and functional differences between asthma with and without FAO. The FAO group was defined by a ratio of forced expiratory volume in 1 s (FEV1 ) to forced vital capacity (FVC), FEV1 /FVC <0.7. Accordingly, we obtained two sets of QCT images at inspiration and expiration of asthma subjects without (N = 24) and with FAO (N = 12). Structural and functional QCT-derived airway variables were extracted, including normalized hydraulic diameter, normalized airway wall thickness, functional small airway disease, and emphysema percentage. A one-dimensional (1D) computational fluid dynamics (CFD) model considering airway deformation was used to compare the pressure distribution between the two groups. The computational pressures showed strong correlations with the pulmonary function test (PFT)-based metrics. In conclusion, asthma participants with FAO had worse lung functions and higher-pressure drops than those without FAO.


Assuntos
Obstrução das Vias Respiratórias , Asma , Humanos , Estudos de Viabilidade , Hidrodinâmica , Asma/complicações , Asma/diagnóstico por imagem , Obstrução das Vias Respiratórias/diagnóstico por imagem , Tomografia Computadorizada por Raios X
12.
Acad Radiol ; 31(2): 648-659, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37550154

RESUMO

RATIONALE AND OBJECTIVES: Ultra short echo time (UTE) magnetic resonance imaging (MRI) pulse sequences have shown promise for airway assessment, but the feasibility and repeatability in the pediatric lung are unknown. The purpose of this work was to develop a semiautomated UTE MRI airway segmentation pipeline from the trachea-to-tertiary airways in pediatric participants and assess repeatability and lumen diameter correlations to lung function. MATERIALS AND METHODS: A total of 29 participants (n = 7 healthy, n = 11 cystic fibrosis, n = 6 asthma, and n = 5 ex-preterm), aged 7-18 years, were imaged using a 3D stack-of-spirals UTE examination at 3 T. Two independent observers performed airway segmentations using a pipeline developed in-house; observer 1 repeated segmentations 1 month later. Segmentations were extracted using region-growing with leak detection, then manually edited if required. The airway trees were skeletonized, pruned, and labeled. Airway lumen diameter measurements were extracted using ray casting. Intra- and interobserver variability was assessed using the Sørensen-Dice coefficient (DSC) and intra-class correlation coefficient (ICC). Correlations between lumen diameter and pulmonary function were assessed using Spearman's correlation coefficient. RESULTS: For airway segmentations and lumen diameter, intra- and interobserver DSCs were 0.88 and 0.80, while ICCs were 0.95 and 0.89, respectively. The variability increased from the trachea-to-tertiary airways for intra- (DSC: 0.91-0.64; ICC: 0.91-0.49) and interobserver (DSC: 0.84-0.51; ICC: 0.89-0.21) measurements. Lumen diameter was significantly correlated with forced expiratory volume in 1 second and forced vital capacity (P < .05). CONCLUSION: UTE MRI airway segmentation from the trachea-to-tertiary airways in pediatric participants across a range of diseases is feasible. The UTE MRI-derived lumen measurements were repeatable and correlated with lung function.


Assuntos
Asma , Fibrose Cística , Recém-Nascido , Humanos , Criança , Imageamento Tridimensional/métodos , Pulmão/diagnóstico por imagem , Asma/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
13.
Acta Paediatr ; 113(4): 795-801, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38088477

RESUMO

AIM: Asthma scoring systems rely on physical examination findings. Point of care ultrasound may provide an objective means to document improvement in the work of breathing in paediatric lower airway obstruction. METHODS: Thirty children with wheeze on physical examination (cases) and 15 children presenting with abdominal pain (controls) were studied. Using point-of-care ultrasound, m-mode tracing of lung was recorded above the right hemidiaphragm at the midclavicular line. Pleural line slope and excursion were measured before and after treatment. RESULTS: Twenty patients had a final slope measurement under 20°, and only three were admitted-one for hypoxia that resolved prior to ascending to the ward and another for poor compliance. Average decrease in pleural line slope after treatment was 43% and average decrease in pleural line excursion was 32%. Of the 10 children admitted, 8 had measurements over 25°. The correlation coefficient between pleural slope and pleural excursion was 0.67. All controls had a horizontal m-mode tracing at the pleural line. CONCLUSION: Oscillation of the m-mode line at the pleura is seen in children with lower airway obstruction and is absent in controls. There appears to be a correlation between beta-agonist therapy and decreased pleural line slope and excursion.


Assuntos
Obstrução das Vias Respiratórias , Asma , Humanos , Criança , Pleura/diagnóstico por imagem , Sistemas Automatizados de Assistência Junto ao Leito , Pulmão/diagnóstico por imagem , Asma/diagnóstico por imagem , Asma/tratamento farmacológico , Ultrassonografia
14.
Acad Radiol ; 31(4): 1666-1675, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37977888

RESUMO

RATIONALE AND OBJECTIVES: The current clinical standard for functional imaging of patients with lung ailments is nuclear medicine scintigraphy and Single Photon Emission Computed Tomography (SPECT) which detect the gamma decay of inhaled radioactive tracers. Hyperpolarized (HP) Xenon-129 MRI (XeMRI) of the lungs has recently been FDA approved and provides similar functional images of the lungs with higher spatial resolution than scintigraphy and SPECT. Here we compare Technetium-99m (99mTc) diethylene-triamine-pentaacetate scintigraphy and SPECT with HP XeMRI in healthy controls, asthma, and chronic obstructive pulmonary disorder (COPD) patients. MATERIALS AND METHODS: 59 subjects, healthy, with asthma, and with COPD, underwent 99mTc scintigraphy/SPECT, standard spirometry, and HP XeMRI. XeMRI and SPECT images were registered for direct voxel-wise signal comparisons. Images were also compared using ventilation defect percentage (VDP), and a standard 6-compartment method. VDP calculated from XeMRI and SPECT images was compared to spirometry. RESULTS: Median Pearson correlation coefficient for voxel-wise signal comparison was 0.698 (0.613-0.782) between scintigraphy and XeMRI and 0.398 (0.286-0.502) between SPECT and XeMRI. Correlation between VDP measures was r = 0.853, p < 0.05. VDP separated asthma and COPD from the control group and was significantly correlated with FEV1, FEV1/FVC, and FEF 25-75. CONCLUSION: HP XeMRI provides equivalent information to 99mTc SPECT and standard spirometry measures. Additionally, XeMRI is non-invasive, hence it could be used for longitudinal studies for evaluating emerging treatment for lung ailments.


Assuntos
Asma , Doença Pulmonar Obstrutiva Crônica , Isótopos de Xenônio , Humanos , Testes de Função Respiratória , Pulmão/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Imageamento por Ressonância Magnética/métodos , Asma/diagnóstico por imagem
15.
Am J Respir Crit Care Med ; 209(10): 1196-1207, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38113166

RESUMO

Rationale: Density thresholds in computed tomography (CT) lung scans quantify air trapping (AT) at the whole-lung level but are not informative for AT in specific bronchopulmonary segments. Objectives: To apply a segment-based measure of AT in asthma to investigate the clinical determinants of AT in asthma. Methods: In each of 19 bronchopulmonary segments in CT lung scans from 199 patients with asthma, AT was categorized as present if lung attenuation was less than -856 Hounsfield units at expiration in ⩾15% of the lung area. The resulting AT segment score (0-19) was related to patient outcomes. Measurements and Main Results: AT varied at the lung segment level and tended to persist at the patient and lung segment levels over 3 years. Patients with widespread AT (⩾10 segments) had more severe asthma (P < 0.05). The mean (±SD) AT segment score in patients with a body mass index ⩾30 kg/m2 was lower than in patients with a body mass index <30 kg/m2 (3.5 ± 4.6 vs. 5.5 ± 6.3; P = 0.008), and the frequency of AT in lower lobe segments in obese patients was less than in upper and middle lobe segments (35% vs. 46%; P = 0.001). The AT segment score in patients with sputum eosinophils ⩾2% was higher than in patients without sputum eosinophilia (7.0 ± 6.1 vs. 3.3 ± 4.9; P < 0.0001). Lung segments with AT more frequently had airway mucus plugging than lung segments without AT (48% vs. 18%; P ⩽ 0.0001). Conclusions: In patients with asthma, air trapping is more severe in those with airway eosinophilia and mucus plugging, whereas those who are obese have less severe trapping because their lower lobe segments are spared.


Assuntos
Asma , Eosinofilia , Obesidade , Tomografia Computadorizada por Raios X , Humanos , Asma/diagnóstico por imagem , Asma/fisiopatologia , Masculino , Feminino , Pessoa de Meia-Idade , Obesidade/complicações , Obesidade/fisiopatologia , Adulto , Eosinofilia/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Idoso , Índice de Massa Corporal
16.
J Aerosol Med Pulm Drug Deliv ; 36(4): 210-227, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37585546

RESUMO

In disease, lung function and structure are heterogeneous, and aerosol transport and local deposition vary significantly among parts of the lung. Understanding such heterogeneity is relevant to aerosol medicine and for quantifying mucociliary clearance from different parts of the lung. In this chapter, we describe positron emission tomography (PET) imaging methods to quantitatively assess the deposition of aerosol and ventilation distribution within the lung. The anatomical information from computed tomography (CT) combined with the PET-deposition data allows estimates of airway surface concentration and peripheral tissue dosing in bronchoconstricted asthmatic subjects. A theoretical framework is formulated to quantify the effects of heterogeneous ventilation, uneven aerosol ventilation distribution in bifurcations, and varying escape from individual airways along a path of the airway tree. The framework is applied to imaging data from bronchoconstricted asthmatics to assess the contributions of these factors to the unevenness in lobar deposition. Results from this analysis show that the heterogeneity of ventilation contributes on average to more than one-third of the variability in interlobar deposition. Actual contribution of ventilation in individual lungs was variable and dependent on the breathing rate used by the subject during aerosol inhalation; the highest contribution was in patients breathing slowly. In subjects breathing faster, contribution of ventilation was reduced, with more expanded lobes showing lower deposition per unit ventilation than less expanded ones in these subjects. The lobar change in expansion measured from two static CT scans, which is commonly used as a surrogate for ventilation, did not correlate with aerosol deposition or with PET-measured ventilation. This suggests that dynamic information is needed to provide proper estimates of ventilation for asthmatic subjects. We hope that the enhanced understanding of the causes of heterogeneity in airway and tissue dosing using the tools presented here will help to optimize therapeutic effectiveness of inhalation therapy while minimizing toxicity.


Assuntos
Asma , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Administração por Inalação , Aerossóis e Gotículas Respiratórios , Pulmão/diagnóstico por imagem , Asma/diagnóstico por imagem
17.
Clin Nucl Med ; 48(10): e494-e495, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37566807

RESUMO

ABSTRACT: A 53-year-old man with persisting increased serum prostate-specific antigen level (9.53 ng/mL) and repeated negative prostate biopsies was referred for a PET/CT with 68 Ga-PSMA-11. The PET/CT revealed focal uptake in the prostate suggestive of localized prostate cancer. Incidentally, it also showed a diffuse uptake in the tracheobronchial tree suspicious for a benign etiology. Because of the clinical history of asthma exacerbation in the previous week, further supplementary studies were performed showing a pathological fractional exhaled nitric oxide level (92 ppb; reference values, <25 ppb) and mild airway obstruction in the spirometry. These findings confirmed asthma as an inflammatory etiology of the tracheobronchial PSMA uptake.


Assuntos
Asma , Neoplasias da Próstata , Masculino , Humanos , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Oligopeptídeos , Ácido Edético , Radioisótopos de Gálio , Neoplasias da Próstata/patologia , Asma/complicações , Asma/diagnóstico por imagem
19.
J Pak Med Assoc ; 73(Suppl 4)(4): S151-S155, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37482849

RESUMO

Objectives: To assess the effect of asthma in children on systolic and diastolic functions of the heart, and to explore the relationship between the two. Method: The case-controlstudy was conducted at Kafrelsheikh University Hospital, Egypt, from September 2019 to May 2022, and comprised asthmatic children of either gender aged 5-15 years and healthy controls matched for age and gender. The participants were subjected to detailed history, complete examination, spirometry evaluation and conventional and tissue Doppler echocardiography. Myocardial performance index was calculated and compared. Data was analysed using SPSS 22. RESULTS: Of the 120 subjects, 60(50%) were cases; 33(55%) boys and 27(45%) girls with mean age 9.4±2.9 years(range: 5-15 years). The remaining 60(50%)subjects were controls; 34(56.6%) boys and 26(43.3%) girls with mean age 9.7±2.9 years (range: 5-15 years). Left ventricular dimensions, estimated pulmonary artery pressure, and right ventricular dimensions showed no significant inter-group differences (p>0.05), but right ventricular end diastolic diameter was significantly higher in the cases than the controls (p=0.046). Tissue Doppler showed that lateral annular peak Ê, Â, isovolumetric relaxation time and myocardial performance index values were significantly different between the groups (p<0.05). CONCLUSIONS: Tissue Doppler echocardiography could detectsubtle right ventricular diastolic dysfunction in asthmatic children even with no clinical symptoms and normal findings on conventional echocardiography.


Assuntos
Asma , Disfunção Ventricular Direita , Masculino , Feminino , Humanos , Criança , Ecocardiografia Doppler/métodos , Asma/complicações , Asma/diagnóstico por imagem , Ecocardiografia , Diástole , Ventrículos do Coração/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem
20.
Respir Physiol Neurobiol ; 315: 104121, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37473791

RESUMO

Brain functional deficits have been reported in asthma patients which can result in behavioral disorders like depression and anxiety. These deficits may be associated with factors like resistance to treatment, incorrect self-evaluation, and inadequate self-control. However, changes in the brain volume in allergic asthma and the effects of inhaled corticosteroids, the most common anti-inflammatory agents for asthma treatment, on these alterations remain largely unclear. Here, we evaluated depression and anxiety-like behavior as well as volume changes in different brain area, using magnetic resonance imaging in an animal model of allergic asthma with pretreatment of inhaled fluticasone propionate. Asthma-induced behavioral changes were partially, but not completely, prevented by pretreatment with inhaled fluticasone propionate. Volumetry findings showed that the allergen decreased volumes of the corpus callosum and subcortical white matter, as well as the septal region and hippocampus (especially CA1 and fimbria). However, volumes of neocortex, insular, and anterior cingulate cortex increased in asthmatic rats compared to controls. Namely, pretreatment with inhaled fluticasone propionate partially prevented asthma-induced brain volume changes, but not completely. These findings suggest that asthma is associated with structural alterations in the brain, which may contribute to the induction of psychological disorders. Thus, considering brain changes in the clinical assessments could have important implications for asthma treatment.


Assuntos
Antiasmáticos , Asma , Animais , Ratos , Depressão/diagnóstico por imagem , Depressão/tratamento farmacológico , Androstadienos/uso terapêutico , Administração por Inalação , Asma/diagnóstico por imagem , Asma/tratamento farmacológico , Fluticasona/uso terapêutico , Corticosteroides/uso terapêutico , Encéfalo/diagnóstico por imagem , Ansiedade/diagnóstico por imagem , Ansiedade/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...