Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.162
Filtrar
1.
JASA Express Lett ; 4(7)2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38980136

RESUMO

Alzheimer's disease (AD) is a progressive neurodegenerative disorder in which changes in hearing sensitivity precede cognitive decline. Despite a well-known link between dementia and hearing loss, few AD model mouse lines have hearing characterized. We screened for hearing loss using auditory brainstem responses (ABR) in young (3-4 months) and aging (9-10 months) mice with a P301S tauopathy (PS19 mice). Compared to wild types, aging PS19 mice did not show accelerated hearing loss but did show latency differences in centrally generated ABR waveform components. These results suggest that tauopathy causes mild central auditory dysfunction in the absence of overt hearing loss.


Assuntos
Doença de Alzheimer , Modelos Animais de Doenças , Potenciais Evocados Auditivos do Tronco Encefálico , Tauopatias , Animais , Doença de Alzheimer/fisiopatologia , Camundongos , Tauopatias/fisiopatologia , Tauopatias/patologia , Camundongos Transgênicos , Perda Auditiva/fisiopatologia , Perda Auditiva/etiologia , Humanos , Audiometria/métodos
2.
FP Essent ; 542: 7-13, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39018125

RESUMO

Hearing loss is the cause of significant morbidity throughout the United States and the world. Because of numerous factors, such as ongoing noise exposure, poorly controlled chronic disease, and an aging population, the burden of hearing loss is expected to continue to increase. Hearing loss commonly is categorized as conductive, sensorineural, or mixed. The type of hearing loss can be determined through a combination of patient history and physical examination, and then confirmed with audiometry and tympanometry. Advanced imaging is not typically necessary, but it may be helpful in specific instances. The presentation of sudden sensorineural hearing loss should prompt urgent referral to an otolaryngologist and audiologist. Management of this condition is selective but may initially include oral corticosteroids. Management for chronic hearing loss involves the use of hearing aids, which can offer a large benefit to users but historically have been expensive and not covered by many insurance plans. Recent US legislation has made hearing aids more accessible and affordable by allowing direct-to-consumer marketing and offering over-the-counter hearing aids without a clinical evaluation.


Assuntos
Auxiliares de Audição , Humanos , Testes de Impedância Acústica , Audiometria , Perda Auditiva/diagnóstico , Perda Auditiva/terapia , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/terapia , Perda Auditiva Súbita/terapia , Perda Auditiva Súbita/diagnóstico , Estados Unidos
3.
Trends Hear ; 28: 23312165241259704, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38835268

RESUMO

The use of in-situ audiometry for hearing aid fitting is appealing due to its reduced resource and equipment requirements compared to standard approaches employing conventional audiometry alongside real-ear measures. However, its validity has been a subject of debate, as previous studies noted differences between hearing thresholds measured using conventional and in-situ audiometry. The differences were particularly notable for open-fit hearing aids, attributed to low-frequency leakage caused by the vent. Here, in-situ audiometry was investigated for six receiver-in-canal hearing aids from different manufacturers through three experiments. In Experiment I, the hearing aid gain was measured to investigate whether corrections were implemented to the prescribed target gain. In Experiment II, the in-situ stimuli were recorded to investigate if corrections were directly incorporated to the delivered in-situ stimulus. Finally, in Experiment III, hearing thresholds using in-situ and conventional audiometry were measured with real patients wearing open-fit hearing aids. Results indicated that (1) the hearing aid gain remained unaffected when measured with in-situ or conventional audiometry for all open-fit measurements, (2) the in-situ stimuli were adjusted for up to 30 dB at frequencies below 1000 Hz for all open-fit hearing aids except one, which also recommends the use of closed domes for all in-situ measurements, and (3) the mean interparticipant threshold difference fell within 5 dB for frequencies between 250 and 6000 Hz. The results clearly indicated that modern measured in-situ thresholds align (within 5 dB) with conventional thresholds measured, indicating the potential of in-situ audiometry for remote hearing care.


Assuntos
Limiar Auditivo , Auxiliares de Audição , Humanos , Estimulação Acústica , Ajuste de Prótese/métodos , Reprodutibilidade dos Testes , Audiometria/métodos , Audiometria de Tons Puros , Perda Auditiva/diagnóstico , Perda Auditiva/reabilitação , Perda Auditiva/fisiopatologia , Audição , Valor Preditivo dos Testes , Pessoas com Deficiência Auditiva/reabilitação , Pessoas com Deficiência Auditiva/psicologia , Desenho de Equipamento , Masculino , Feminino
4.
Otol Neurotol ; 45(7): 740-744, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38942612

RESUMO

OBJECTIVE: The objective of this study is to assess the accuracy of the Mimi Hearing Test (MHT) mobile application in the detection of air conduction (AC) thresholds and in screening for moderate hearing loss. STUDY DESIGN: Prospective clinical study. SETTING: Tertiary care center. PATIENTS: Participants with or without a varying degree of hearing loss, aged 18 years and over, without cognitive impairment and without active otorrhea or earwax impaction at the time of the hearing assessment were included. INTERVENTION: Subjects with a ranging severity of hearing loss underwent a conventional in-booth audiogram as well as mobile-based screening with MHT in a quiet room (45.5 dB background noise) on the same day. Both regular over-the-ear and noise-canceling headphones were tested with MHT. MAIN OUTCOME MEASURES: Comparisons of AC thresholds between conventional audiometry and mobile-based audiometry at discrete frequencies and with pure-tone averages (PTA) were performed. RESULTS: A total of 75 adults (mean age: 56.2 yr, 54.7% male) were recruited and 63 used for analysis. Of the thresholds measured with MHT using regular headphones, 44.0% were within 10 dB of the conventional audiogram, compared to 39.3% using noise-canceling headphones. MHT demonstrated best accuracy at high frequencies (4-8 kHz). When screening for moderate hearing loss (PTA >40 dB HL), MHT demonstrated a sensitivity and specificity of 100.0% and 80.2%, respectively. CONCLUSIONS: MHT is reliable for identifying moderate hearing loss but lacks precision in detecting thresholds at low frequencies. Noise canceling headphones seem to improve its precision at 4,000 Hz only.


Assuntos
Perda Auditiva , Aplicativos Móveis , Humanos , Pessoa de Meia-Idade , Masculino , Feminino , Adulto , Estudos Prospectivos , Idoso , Perda Auditiva/diagnóstico , Audiometria de Tons Puros/métodos , Audiometria de Tons Puros/instrumentação , Audiometria/métodos , Audiometria/instrumentação , Limiar Auditivo/fisiologia , Sensibilidade e Especificidade , Reprodutibilidade dos Testes , Idoso de 80 Anos ou mais
5.
JAMA Oncol ; 10(7): 912-922, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38842797

RESUMO

Importance: Cisplatin is highly ototoxic but widely used. Evidence is lacking regarding cisplatin-related hearing loss (CRHL) in adult-onset cancer survivors with comprehensive audiologic assessments (eg, Words-in-Noise [WIN] tests, full-spectrum audiometry, and additional otologic measures), as well as the progression of CRHL considering comorbidities, modifiable factors associated with risk, and cumulative cisplatin dose. Objective: To assess CRHL with comprehensive audiologic assessments, including the WIN, evaluate the longitudinal progression of CRHL, and identify factors associated with risk. Design, Setting, and Participants: The Platinum Study is a longitudinal study of cisplatin-treated testicular cancer survivors (TCS) enrolled from 2012 to 2018 with follow-up ongoing. Longitudinal comprehensive audiologic assessments at Indiana University and Memorial Sloan Kettering Cancer Center included 100 participants without audiometrically defined profound hearing loss (HL) at baseline and at least 3.5 years from their first audiologic assessment. Data were analyzed from December 2013 to December 2022. Exposures: Factors associated with risk included cumulative cisplatin dose, hypertension, hypercholesterolemia, diabetes, tobacco use, physical inactivity, body mass index, family history of HL, cognitive dysfunction, psychosocial symptoms, and tinnitus. Main Outcomes and Measures: Main outcomes were audiometrically measured HL defined as combined-ears high-frequency pure-tone average (4-12 kHz) and speech-recognition in noise performance measured with WIN. Multivariable analyses evaluated factors associated with risk for WIN scores and progression of audiometrically defined HL. Results: Median (range) age of 100 participants at evaluation was 48 (25-67) years; median (range) time since chemotherapy: 14 (4-31) years. At follow-up, 78 (78%) TCS had audiometrically defined HL; those self-reporting HL had 2-fold worse hearing than TCS without self-reported HL (48 vs 24 dB HL; P < .001). A total of 54 (54%) patients with self-reported HL showed clinically significant functional impairment on WIN testing. Poorer WIN performance was associated with hypercholesterolemia (ß = 0.88; 95% CI, 0.08 to 1.69; P = .03), lower-education (F1 = 5.95; P = .004), and severity of audiometrically defined HL (ß̂ = 0.07; 95% CI, 0.06 to 0.09; P < .001). CRHL progression was associated with hypercholesterolemia (ß̂ = -4.38; 95% CI, -7.42 to -1.34; P = .01) and increasing age (ß̂ = 0.33; 95% CI, 0.15 to 0.50; P < .001). Importantly, relative to age-matched male normative data, audiometrically defined CRHL progression significantly interacted with cumulative cisplatin dose (F1 = 5.98; P = .02); patients given 300 mg/m2 or less experienced significantly less progression, whereas greater temporal progression followed doses greater than 300 mg/m2. Conclusions and Relevance: Follow-up of cisplatin-treated cancer survivors should include strict hypercholesterolemia control and regular audiological assessments. Risk stratification through validated instruments should include querying hearing concerns. CRHL progression relative to age-matched norms is likely associated with cumulative cisplatin dose; investigation over longer follow-up is warranted.


Assuntos
Cisplatino , Perda Auditiva , Humanos , Cisplatino/efeitos adversos , Cisplatino/uso terapêutico , Masculino , Adulto , Perda Auditiva/induzido quimicamente , Perda Auditiva/epidemiologia , Perda Auditiva/diagnóstico , Pessoa de Meia-Idade , Estudos Longitudinais , Neoplasias Testiculares/tratamento farmacológico , Antineoplásicos/efeitos adversos , Antineoplásicos/uso terapêutico , Fatores de Risco , Sobreviventes de Câncer , Audiometria , Ototoxicidade/etiologia , Ototoxicidade/epidemiologia
6.
Int J Pediatr Otorhinolaryngol ; 181: 111982, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38776720

RESUMO

OBJECTIVE: To describe the prevalence of routine white noise exposure in children who undergo sound field audiometry. METHODS: A retrospective cohort study was conducted at a pediatric otolaryngology clinic affiliated with an academic tertiary care hospital. The medical records of children who underwent sound field audiometry were reviewed and data was collected regarding demographics and audiogram results. The group was divided into two cohorts based on routine exposure to white noise. Children exposed to white noise were tested with warble tones, while those not exposed were tested with narrow-band noise. RESULTS: 127 patients underwent sound field audiometry testing, of which 96 (75.6%) were reported by their parents to use white noise for sleep. The mean age at time of testing was 1.6 years (95% Confidence Interval [CI] 1.5-1.7). 104 (81.9%) children were able to respond to at least four of the sound field thresholds, and there was no significant difference between the children exposed to white noise and those who were not (P = 0.459). Mean pure tone average (PTA) was 26.2 dB (95% CI 25.2-27.2) and mean speech reception threshold (SRT) was 19.2 dB (95% CI 18.2-20.2). The sound field response rate, PTA, and SRT were similar between these two groups. CONCLUSIONS: The routine use of white noise therapy was extremely common in this pediatric population. The use of warble tones as the audiometric stimuli for children exposed to white noise resulted in similar testing success compared to the use of narrow-band noise in children not exposed to white noise.


Assuntos
Audiometria de Tons Puros , Ruído , Humanos , Masculino , Feminino , Estudos Retrospectivos , Ruído/efeitos adversos , Lactente , Pré-Escolar , Perda Auditiva Provocada por Ruído/diagnóstico , Perda Auditiva Provocada por Ruído/epidemiologia , Perda Auditiva Provocada por Ruído/etiologia , Limiar Auditivo , Estudos de Coortes , Criança , Audiometria/métodos , Prevalência
7.
Am J Otolaryngol ; 45(4): 104345, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38701729

RESUMO

PURPOSE: To assess the audiometric outcomes following surgical repair of spontaneous temporal bone cerebrospinal fluid otorrhea and compare different surgical approaches. MATERIALS AND METHODS: Retrospective review of adults (≥18 years old) who underwent repair of spontaneous CSF leak between 2011 and 2022. Audiometric outcomes were compared across the three surgical groups: transmastoid, middle cranial fossa and combined. RESULTS: Thirty-nine patients (40 ears) met the inclusion criteria (71.8 % females; mean age 59.77 +/- 12.4). Forty-two percent underwent transmastoid, 12.5 % middle cranial fossa and 45 % transmastoid-middle cranial fossa. Four patients (10 %) had recurrence, 3 in the transmastoid group and 1 in the combined approach. The mean change in air-bone gap (ABG) for all patients (postoperative-preoperative) was -7.4 (paired t-test, p-value = 0.0003). The postoperative ABG was closed in 28 (70 %) ears (postoperative ABG ≤ 15). The mean change in pure tone average (PTA) for all patients (postoperative-preoperative) was -4.1 (paired t-test, p-value = 0.13). The mean change in word recognition scores (WRS) for all patients (postoperative-preoperative) was -3 (paired t-test, p-value = 0.35). On multivariable analysis (controlling for site and reconstruction material), there was no significant difference in ABG, PTA and WRS change between surgical groups. CONCLUSIONS: Transmastoid, middle cranial fossa and combined approaches are all effective in treatment of spontaneous CSF leaks and all showed mean decrease in post-operative ABG. Transmastoid approach showed the greatest decrease in ABG and PTA (although middle cranial fossa approach shows the greatest decrease, when excluding profound hearing loss in a patient with superior canal dehiscence). Further studies comparing audiometric outcomes are needed.


Assuntos
Otorreia de Líquido Cefalorraquidiano , Osso Temporal , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Osso Temporal/cirurgia , Otorreia de Líquido Cefalorraquidiano/cirurgia , Otorreia de Líquido Cefalorraquidiano/etiologia , Resultado do Tratamento , Idoso , Fossa Craniana Média/cirurgia , Audiometria de Tons Puros , Adulto , Vazamento de Líquido Cefalorraquidiano/cirurgia , Vazamento de Líquido Cefalorraquidiano/etiologia , Processo Mastoide/cirurgia , Audiometria
8.
Am J Otolaryngol ; 45(4): 104346, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38703613

RESUMO

OBJECTIVES: Recently, patients with certain legacy cochlear implants (CIs) have sought out reimplantation to enjoy the benefits offered by newer processor technology. This decision can be difficult, especially when the individual relies exclusively on the device for communication and scores at the ceiling of performance metrics. To date, most outcome data is derived from reimplantation of a non-functioning CI-a relatively easy decision. The aim of this study is to report hearing outcomes following reimplantation of legacy implants to guide surgeons and patients approaching this high-stakes clinical situation. PATIENTS AND INTERVENTION: Four patients implanted with Advanced Bionics Clarion C1 devices over 20 years ago underwent reimplantation. RESULTS: Three reimplanted patients demonstrated a maintenance or improvement in their audiometric performance with one patient experiencing only a 5 % decrease in AzBioQ score. Each patient expressed satisfaction with the expansion of technological capabilities including improved battery life, and device connectivity. There were no failed reimplantations or other adverse effects. CONCLUSIONS: Reimplantation of a functioning legacy CI result in stability or improvement in auditory performance. All individuals in this series report that they enjoy the new connectivity and programming technologies. As the rate advancement in CI technology continues to increase and newer device architectures emerge, these data will help to inform the decision to reimplant functioning devices.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Resultado do Tratamento , Implante Coclear/métodos , Reimplante/métodos , Reoperação , Adulto , Idoso , Audição , Satisfação do Paciente , Audiometria
9.
Artigo em Chinês | MEDLINE | ID: mdl-38811175

RESUMO

Objective: This study aimed to compare the audiological characteristics between children with unilateral auditory neuropathy (UAN) and single-sided deafness (SSD) to establish a valid basis for the differential diagnosis of children with UAN. Methods: A retrospective analysis was conducted on audiological and imaging evaluations of children with UAN and SSD who were treated at Beijing Children's Hospital of Capital Medical University between May 2015 and June 2023. There were 17 children with UAN, comprising 10 males and 7 females, with an average age of 4.7 years. Additionally, there were 43 children with SSD, consisting of 27 males and 16 females, with an average age of 6.5 years. Audiological assessments included Auditory brainstem response (ABR), Steady-state auditory evoked potential (ASSR), Behavioural audiometry, Cochlear microphonic potential (CM), Distortino-product otoacoustic emission (DPOAE), and acoustic immittance test. The results of the audiological assessment and imaging phenotypic between the two groups of children were compared and analyzed by applying SPSS 27.0 statistical software. Results: (1) The UAN group (77.8%) had a significantly higher rate of ABR wave IIIL than the SSD group (20.9%) (P<0.01). The PA thresholds at 500 Hz and 1 000 Hz of children with SSD were higher than those of children with UAN, while the ASSR thresholds at 500 Hz, 1000 Hz, 2 000 Hz, and 4 000 Hz of children with SSD were significantly higher than those of children with UAN (P<0.05). (2) The degree of hearing loss in both UAN and SSD children was predominantly complete hearing loss. The percentage of complete hearing loss was significantly higher (χ²=4.353, P=0.037) in the SSD group (93.0%, 40/43) than in the UAN group (63.6%, 7/11). However, the percentage of profound hearing loss was significantly higher in the UAN group (27.3%, 3/11) than in the SSD group (2.3%, 1/43) (Fisher's exact test, P=0.023). In terms of hearing curve configuration, the percentage of flat type was significantly higher in the SSD group (76.7%, 33/43) than in the UAN group (36.4%, 4/11). The proportion of the UAN group (27.3%, 3/11) was significantly higher than that in the SSD group (2.3%, 1/43) in ascending type (P<0.05). There were no statistically significant differences in the hearing curves of the declining type and other types between the two groups (P>0.05). (3) The proportion of imaging assessment without abnormality was significantly more common in the UAN group (81.8%) than in the SSD group (37.1%) (χ²=6.695, P=0.015). Conclusions: Compared to children with SSD, the occurrence of wave IIIL on the ABR test was significantly more common in children with UAN. The percentage of ascending hearing curves was significantly higher in children with UAN than in children with SSD. ASSR thresholds were significantly lower in children with UAN. The normal imaging phenotype was significantly more common in children with UAN than in children with SSD.


Assuntos
Potenciais Evocados Auditivos do Tronco Encefálico , Perda Auditiva Central , Humanos , Feminino , Masculino , Estudos Retrospectivos , Pré-Escolar , Criança , Perda Auditiva Central/diagnóstico , Perda Auditiva Central/fisiopatologia , Perda Auditiva Unilateral/diagnóstico , Perda Auditiva Unilateral/fisiopatologia , Limiar Auditivo , Audiometria/métodos , Diagnóstico Diferencial
10.
JAMA Otolaryngol Head Neck Surg ; 150(7): 537-544, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38722618

RESUMO

Importance: Although patient-reported outcomes provide valuable insights, these subjective data may not align with objective test results. Hearing loss is a pervasive problem, such that concordance between subjective perceptions of hearing ability and objective audiogram assessments would be beneficial. Objectives: To determine (1) whether psychological status is an effect modifier of the association between subjective patient reports of hearing ability and objective audiometry results, and (2) whether any effect modification observed in standard static questionnaires would be either mitigated or exacerbated by adaptive testing based on Item Response Theory analyses. Design, Setting, and Participants: This diagnostic study at a tertiary care center and community-based practice included consecutive adults who presented with queries related to hearing loss. Participants were recruited and enrolled and data analyses occurred from 2022 to 2024. Exposures: Participants prospectively reported their hearing-specific abilities through either a standard static or adaptive version of the Inner Effectiveness of Auditory Rehabilitation (EAR) scale, alongside validated measures of their mental health and audiometry. Word recognition scores (WRS) and pure tone averages (PTA) were used to analyze audiometric testing. Main Outcomes and Measures: The association between subjective Inner EAR results and audiometry was evaluated. Stratified analyses were used to assess for effect modification by psychological status. The results of standard static and adaptive testing were compared. Results: In this study of 395 patients (mean [range] age, 55.9 [18-89] years; 210 [53.2%] female), standard static Inner EAR mean scores were appropriately higher in patients with higher (better) WRS (50.7, 95% CI, 46.4-54.9), compared with patients with lower (worse) WRS (34.7, 95% CI, 24.3-45.1). However, among patients with worse mental health, there was no association between standard static Inner EAR scores and WRS. In contrast, adaptive Inner EAR mean scores were significantly higher for those with better WRS, regardless of mental health status. Thus, effect modification was observed in standard static assessments, whereas adaptive testing remained durably associated with audiometry, regardless of mental health. Conclusions and Relevance: Psychological status was an effect modifier of the association between standard Inner EAR scale scores and audiometry, with a positive association observed only in those with better mental health. Adaptive testing scores, however, remained significantly associated with audiometry, even when mental status was worse. Adaptive testing may stabilize the association between subjective and objective hearing outcomes.


Assuntos
Perda Auditiva , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Perda Auditiva/psicologia , Idoso , Audiometria de Tons Puros , Adulto , Medidas de Resultados Relatados pelo Paciente , Estudos Prospectivos , Inquéritos e Questionários , Audiometria , Saúde Mental
11.
Eur Arch Otorhinolaryngol ; 281(8): 4373-4378, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38739186

RESUMO

OBJECTIVE: This study aimed to compare daily and total recreational music exposure levels and extended-spectrum audiogram results in young adults without pre-existing hearing problems. DESIGN: The study included healthy volunteers aged 18-25 with no known ear disease or hearing loss. Participants completed a questionnaire, underwent otoscopic and tympanometric examinations, and determined preferred music volumes in an audiometry booth using calibrated music samples of their preferred genres. Hearing thresholds up to 16 kiloHertz (kHz) were measured. Daily music exposure for each participant was normalized to 8 h to calculate a time-weighted average of 8 h (TWA8). Total exposure (TE) was calculated by multiplying TWA8 by the number of years of music listening. RESULTS: A total of 32.4% of participants had TWA8s above 65 dB. Their hearing thresholds at 125, 250, 500, and 16,000 Hz and the average of 125 Hz-8 kHz were significantly higher. Participants with TWA8s above 65 dB were also more prone to speaking loudly and experiencing communication difficulties on the phone. Those with a TE of more than 400 experienced significantly more speech discrimination difficulty in noisy environments and temporary hearing loss/tinnitus after exposure to loud music. Participants with a TE above 700 had worse thresholds at 4, 14, and 16 kHz frequencies, as well as 125-8000 Hz and 500-4000 Hz averages compared to those with a TE below 700. CONCLUSIONS: This study provides evidence that recreational music with much lower exposure levels than the universally accepted TWA8 of 85 dB could negatively impact hearing in healthy young adults. Therefore, maintaining a maximum TWA8 of 65 dB is recommended.


Assuntos
Limiar Auditivo , Música , Humanos , Adulto Jovem , Masculino , Feminino , Adulto , Adolescente , Limiar Auditivo/fisiologia , Perda Auditiva Provocada por Ruído/etiologia , Inquéritos e Questionários , Voluntários Saudáveis , Testes de Impedância Acústica , Recreação , Otoscopia/métodos , Audiometria
12.
Medicina (Kaunas) ; 60(5)2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38792986

RESUMO

Background and Objectives: Besides classical stapedotomy, reverse stapedotomy has been used for many years in the management of otosclerosis. Our study aims to investigate whether reversing the surgical steps in stapedotomy impacts vestibular function and hearing improvement. Materials and Methods: A cohort of 123 patients underwent either classic or reverse stapedotomy procedures utilizing a fiber-optic argon laser. Audiological assessments, following the guidelines of the Committee on Hearing and Equilibrium, were conducted, including pure tone average, air-bone (AB) gap, overclosure, and AB gap closure. Vestibular evaluation involved pre- and postoperative comparison of rotatory test parameters, including frequency, amplitude, and slow phase velocity of nystagmus. Results: The study demonstrated an overall median overclosure of 3.3 (3.3, 5.0) dB and a mean AB gap closure of 20.3 ± 8.8 dB. Postoperative median AB gap was 7.5 (7.5, 11.3) dB in the reverse stapedotomy group and 10.0 (10.0, 12.5) dB in the classic stapedotomy group. While overclosure and AB gap closure were marginally superior in the reverse stapedotomy group, these differences did not reach statistical significance. No significant disparities were observed in the frequency, slow phase velocity, or amplitude of nystagmus in the rotational test. Conclusions: Although not always possible, reverse stapedotomy proved to be a safe surgical technique regarding postoperative outcomes. Its adoption may mitigate risks associated with floating footplate, sensorineural hearing loss, and incus luxation/subluxation, while facilitating the learning curve for less experienced ear surgeons.


Assuntos
Otosclerose , Cirurgia do Estribo , Humanos , Cirurgia do Estribo/métodos , Cirurgia do Estribo/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Otosclerose/cirurgia , Otosclerose/fisiopatologia , Audiometria/métodos , Estudos de Coortes , Resultado do Tratamento , Audiometria de Tons Puros/métodos , Idoso , Testes de Função Vestibular/métodos
13.
Trends Hear ; 28: 23312165241242235, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38738302

RESUMO

The objective of this project was to establish cutoff scores on the tinnitus subscale of the Tinnitus and Hearing Survey (THS) using a large sample of United States service members (SM) with the end goal of guiding clinical referrals for tinnitus evaluation. A total of 4,589 SM undergoing annual audiometric surveillance were prospectively recruited to complete the THS tinnitus subscale (THS-T). A subset of 1,304 participants also completed the Tinnitus Functional Index (TFI). The original 5-point response scale of the THS (THS-T16) was modified to an 11-point scale (THS-T40) for some participants, to align with the response scale of the TFI. Age, sex, hearing loss, and self-reported tinnitus bother were also recorded. The THS-T was relatively insensitive to hearing, but self-reported bothersome tinnitus was significantly associated with the THS-T40 score. Receiver operating characteristic analysis was used to determine cutoff scores on the THS-T that aligned with recommended cutoff values for clinical intervention on the TFI. A cutoff of 9 on the THS-T40 aligns with a TFI cutoff of 25, indicating a patient may need intervention for tinnitus. A cutoff of 15 aligns with a TFI cutoff of 50, indicating that more aggressive intervention for tinnitus is warranted. The THS-T is a viable tool to identify patients with tinnitus complaints warranting clinical evaluation for use by hearing conservation programs and primary care clinics. The THS-T40 cutoff scores of 9 and 15 provide clinical reference points to guide referrals to audiology.


Assuntos
Zumbido , Humanos , Zumbido/diagnóstico , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Estudos Prospectivos , Estados Unidos , Audição , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Curva ROC , Inquéritos e Questionários , Autorrelato , Audiometria/métodos
14.
Otol Neurotol ; 45(5): e393-e399, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38573598

RESUMO

HYPOTHESIS: Preimplantation word scores cannot reliably predict postimplantation outcomes. BACKGROUND: To date, there is no model based on preoperative data that can reliably predict the postoperative outcomes of cochlear implantation in the postlingually deafened adult patient. METHODS: In a group of 228 patients who received a cochlear implant between 2002 and 2021, we tested the predictive power of nine variables (age, etiology, sex, laterality of implantation, preimplantation thresholds and word scores, as well as the design, insertion approach, and angular insertion depth of the electrode array) on postimplantation outcomes. Results of multivariable linear regression analyses were then interpreted in light of data obtained from histopathological analyses of human temporal bones. RESULTS: Age and etiology were the only significant predictors of postimplantation outcomes. In agreement with many investigations, preimplantation word scores failed to significantly predict postimplantation outcomes. Analysis of temporal bone histopathology suggests that neuronal survival must fall below 40% before word scores in quiet begin to drop. Scores fall steeply with further neurodegeneration, such that only 20% survival can support acoustically driven word scores of 50%. Because almost all cochlear implant implantees have at least 20% of their spiral ganglion neurons (SGNs) surviving, it is expected that most cochlear implant users on average should improve to at least 50% word recognition score, as we observed, even if their preimplantation score was near zero as a result of widespread hair cell damage and the fact that ~50% of their SGNs have likely lost their peripheral axons. These "disconnected" SGNs would not contribute to acoustic hearing but likely remain electrically excitable. CONCLUSION: The relationship between preimplantation word scores and data describing the survival of SGNs in humans can explain why preimplantation word scores obtained in unaided conditions fail to predict postimplantation outcomes.


Assuntos
Implante Coclear , Perda Auditiva , Idioma , Percepção da Fala , Idoso , Feminino , Masculino , Pessoa de Meia-Idade , Audiometria , Implante Coclear/instrumentação , Implante Coclear/métodos , Surdez/cirurgia , Perda Auditiva/cirurgia , Perda Auditiva Neurossensorial/cirurgia , Modelos Lineares , Prognóstico , Estudos Retrospectivos , Percepção da Fala/fisiologia , Osso Temporal/patologia , Resultado do Tratamento , Humanos
15.
Am J Otolaryngol ; 45(4): 104294, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38657534

RESUMO

PURPOSE: The number of cochlear implant (CI) surgeries is growing over time, with the risk of overloading CI centers in the post-surgical management. Telemedicine is a possible solution to address this phenomenon. Remote Check (RC) is an application that is specific for CI recipients monitoring. The aim of this study is to evaluate the feasibility of application, potential economic impact and patients' acceptance of RC. METHODS: The study is retrospective investigation, data on clinical, audiological features (from remote and on-site evaluation), and satisfaction surveys of 66 consecutive patients were collected; costs required for RC and for on-site evaluations were recorded as well. RESULTS: One hundred and ninety RC sessions were completed by the patients (2.88 sessions per patient). RC and on-site audiometry significantly correlated except for the 500 Hz frequency. Estimated costs for the Italian National Health System for RC review and on-site evaluations were 1.32€ and 3.49€ per minute, respectively. High satisfaction for RC was reached in 91 % of patients. CONCLUSION: RC revealed to be a reliable, cost-effective and well accepted tool in CI monitoring. This study preliminarily supports the hypothesis that RC could be a valid instrument to reduce CI management overload in the outpatient clinic.


Assuntos
Implante Coclear , Implantes Cocleares , Estudos de Viabilidade , Satisfação do Paciente , Telemedicina , Humanos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Adulto , Implantes Cocleares/economia , Implante Coclear/métodos , Implante Coclear/economia , Idoso , Adolescente , Adulto Jovem , Análise Custo-Benefício , Itália , Audiometria , Criança , Idoso de 80 Anos ou mais
16.
Am J Otolaryngol ; 45(4): 104337, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38677145

RESUMO

OBJECTIVE: To describe an AI model to facilitate adult cochlear implant candidacy prediction based on basic demographical data and standard behavioral audiometry. METHODS: A machine-learning approach using retrospective demographic and audiometric data to predict candidacy CNC word scores and AzBio sentence in quiet scores was performed at a tertiary academic center. Data for the model were derived from adults completing cochlear implant candidacy testing between January 2011 and March 2023. Comparison of the prediction model to other published prediction tools and benchmarks was performed. RESULTS: The final dataset included 770 adults, encompassing 1045 AzBio entries, and 1373 CNC entries. Isophoneme scores and word recognition scores exhibited strongest importance to both the CNC and AzBio prediction models, followed by standard pure tone average and low-frequency pure tone average. The mean absolute difference between the predicted and actual score was 15 percentage points for AzBio sentences in quiet and 13 percentage points for CNC word scores, approximating anticipated test-retest constraints inherent to the variables incorporated into the model. Our final combined model achieved an accuracy of 87 % (sensitivity: 90 %; precision: 80 %). CONCLUSION: We present an adaptive AI model that predicts adult cochlear implant candidacy based on routine behavioral audiometric and basic demographical data. Implementation efforts include a public-facing online prediction tool and accompanying smartphone program, an embedded notification flag in the electronic medical record to alert providers of potential candidates, and a program to retrospectively engage past patients who may be eligible for cochlear implantation based on audiogram results.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Adulto , Estudos Retrospectivos , Implante Coclear/métodos , Idoso , Audiometria/métodos , Aprendizado de Máquina , Seleção de Pacientes , Adulto Jovem , Idoso de 80 Anos ou mais
17.
Am J Audiol ; 33(2): 476-491, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38668699

RESUMO

PURPOSE: This project addressed the uses of a loudspeaker array for audiometric measurements. It sought to evaluate a prototype compact array in terms of the reliability of test results across sound booths. METHOD: A seven-loudspeaker array was developed to deliver sounds from -60° to +60° on an arc with a radius of 0.5 m. The system was equipped with a head position sensing system to maintain the listener's head near the optimal test position. Three array systems were distributed to each of the two test sites for within-subject assessments of booth equivalence on tests of sound localization, speech reception in noise, and threshold detection. A total of 36 subjects participated, 18 at each test site. RESULTS: Results showed excellent interbooth consistency on tests of sound localization using speech and noise signals, including conditions in which one or both ears were covered with a muff. Booth consistency was also excellent on sound field threshold measurements for detecting quasi-diffuse noise bands. Nonequivalence was observed in some cases of speech-in-noise tests, particularly with a small one-person booth. Acoustic analyses of in situ loudspeaker responses indicated that some of the nonequivalent comparisons on speech-in-noise tests could be traced to the effects of reflections. CONCLUSIONS: Overall, the results demonstrate the utility and reliability of a compact array for the assessment of localization ability, speech reception in noise, and sound field thresholds. However, the results indicate that researchers and clinicians should be aware of the reflection effects that can influence the results of sound field tests in which signal and noise levels from separate loudspeakers are critical.


Assuntos
Localização de Som , Humanos , Masculino , Adulto , Feminino , Reprodutibilidade dos Testes , Desenho de Equipamento , Adulto Jovem , Ruído , Audiometria/métodos , Audiometria/instrumentação , Limiar Auditivo , Amplificadores Eletrônicos , Percepção da Fala , Pessoa de Meia-Idade
18.
Am Fam Physician ; 109(4): 316-323, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38648830

RESUMO

Hearing loss is a prevalent, chronic condition in the United States; it is often gradual and progressive and is underreported by patients and undertreated by physicians. The impaired ability to effectively hear and communicate may result in negative emotional, cognitive, economic, and social consequences for individuals and may pose a safety risk. Questionnaires and smartphone apps are available to help identify and evaluate self-perceived hearing loss. Physicians should assess for objective hearing impairment when the patient or family member raises a concern or if cognitive or mood symptoms are present that could be influenced by hearing loss. Three types of hearing loss exist: conductive, sensorineural, and mixed. Pure-tone audiometry uses an audiometer and is reported on an audiogram; it is the most accurate method for hearing loss detection. It can be used for screening or comprehensive testing when combined with tympanometry, speech-reception thresholds, and word-recognition testing. Audiograms that show a unilateral or asymmetrical sensorineural hearing loss can be signs of retrocochlear pathology and warrant additional evaluation by an audiologist and otolaryngologist as well as imaging studies. Medicare Parts A and B do not pay for hearing aids, although some Medicare Advantage (Part C) or supplemental plans may provide insurance coverage for hearing aids. Less expensive, over-the-counter hearing aids may help mild to moderate hearing loss. Family physicians should counsel patients on the importance of protecting their hearing.


Assuntos
Perda Auditiva , Humanos , Perda Auditiva/diagnóstico , Adulto , Estados Unidos , Audiometria de Tons Puros/métodos , Audiometria/métodos
19.
J Neurosurg Pediatr ; 33(5): 496-504, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38427998

RESUMO

OBJECTIVE: Pediatric data regarding treatment via an auditory brainstem implant (ABI) remains sparse. The authors aimed to describe their experience at their institution and to delineate associated demographic data, audiometric outcomes, and surgical parameters. METHODS: An IRB-approved, retrospective chart review was conducted among the authors' pediatric patients who had undergone auditory brainstem implantation between 2012 and 2021. Demographic information including sex, age, race, coexisting syndrome(s), history of cochlear implant placement, average duration of implant use, and follow-up outcomes were collected. Surgical parameters collected included approach, intraoperative findings, number of electrodes activated, and complications. RESULTS: A total of 19 pediatric patients had an ABI placed at the authors' institution, with a mean age at surgery of 4.7 years (range 1.5-17.8 years). A total of 17 patients (89.5%) had bilateral cochlear nerve aplasia/dysplasia, 1 (5.3%) had unilateral cochlear nerve aplasia/dysplasia, and 1 (5.3%) had a hypoplastic cochlea with ossification. A total of 11 patients (57.9%) had a history of cochlear implants that were ineffective and required removal. The mean length of implant use was 5.31 years (0.25-10 years). Two patients (10.5%) experienced CSF-related complications requiring further surgical intervention. The most recent audiometric outcomes demonstrated that 15 patients (78.9%) showed improvement in their hearing ability: 5 with sound/speech awareness, 5 able to discriminate among speech and environmental sounds, and 5 able to understand common phrases/conversation without lip reading. Nine patients (47.4%) are in a school for the deaf and 7 (36.8%) are in a mainstream school with support. CONCLUSIONS: The authors' surgical experience with a multidisciplinary team demonstrates that the retrosigmoid approach for ABI placement in children with inner ear pathologies and severe sensorineural hearing loss is a safe and effective treatment modality. Audiometric outcome data showed that nearly 79% of these patients had an improvement in their environmental and speech awareness. Further multicenter collaborations are necessary to improve these outcomes and potentially standardize/enhance electrode placement.


Assuntos
Audiometria , Implante Auditivo de Tronco Encefálico , Humanos , Criança , Masculino , Feminino , Pré-Escolar , Adolescente , Estudos Retrospectivos , Lactente , Implante Auditivo de Tronco Encefálico/métodos , Resultado do Tratamento , Implantes Auditivos de Tronco Encefálico , Nervo Coclear/cirurgia , Nervo Coclear/anormalidades , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia
20.
Otol Neurotol ; 45(4): 430-433, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38437820

RESUMO

OBJECTIVE: To describe the experience and results from coordinated and closely scheduled radiosurgery and cochlear implantation (CI) in a vestibular schwannoma (VS) cohort. PATIENTS: Patients with VS who underwent radiosurgery followed by CI on the same or next day. INTERVENTIONS: Interventions included sequential radiosurgery and CI. MAIN OUTCOME MEASURES: Tumor control defined by tumor growth on posttreatment surveillance and audiometric outcomes including consonant-nucleus-consonant words and AzBio sentences in quiet. RESULTS: In total, six patients were identified that met the inclusion criteria, with an age range of 38 to 69 years and tumor sizes ranging from 2.0 to 16.3 mm. All patients successfully underwent radiosurgery and CI on the same or immediately successive day. Postoperatively, all patients obtained open-set speech recognition. Consonant-nucleus-consonant word scores ranged from 40 to 88% correct, and AzBio scores ranged from 44 to 94% correct. During posttreatment magnetic resonance imaging surveillance, which ranged from 12 to 68 months, all tumors were noted to be adequately visualized, and no tumor progression was noted. CONCLUSION: Coordinated radiosurgery and CI can be safely performed in patients with VS on the same or next day, serving to decrease burden on patients and increase access to this vital rehabilitative strategy.


Assuntos
Implante Coclear , Implantes Cocleares , Neuroma Acústico , Radiocirurgia , Percepção da Fala , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Implante Coclear/métodos , Neuroma Acústico/cirurgia , Radiocirurgia/métodos , Estudos Retrospectivos , Audiometria , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...