Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.946
Filtrar
1.
J Environ Sci (China) ; 148: 691-701, 2025 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-39095201

RESUMO

Personal care products (PCPs) are a class of emerging pollutants that have attracted public concern owing to their harmful effects on humans and the environment. Biomonitoring data is valuable for insight the levels of PCPs in the human body and can be crucial for identifying potential health hazards. To gain a better understanding of timely exposure profiles and health risk of reproductive-age population to PCPs, we determined six parabens, six benzophenone-type ultraviolet filters, and three disinfectants in 256 urine samples collected from young adults aged 18-44 years in Beijing, China. The urinary levels of benzophenone-3 (BP-3) and 4-hydroxybenzophenone (4-OHBP) were significantly higher in summer compared to winter, suggesting these compounds have different seasonal usage patterns. Moreover, the total concentration of 15 PCPs in female was 430 ng/mL, approximately two times higher than that in male. P­chloro-m-xylenol (PCMX), as a new type of antibacterial agent, has the greatest level among all target analytes, indicating the increasingly use of this antibacterial alternative recently. Five potential influencing factors that lead to the elevated exposure level of PCPs were identified. Over 19% of the target population had a high hazard index value (greater than 1) which was attributed to exposure to propyl paraben (PrP), benzophenone-1 (BP-1), BP-3 and PCMX, indicating that PCPs may pose a relatively high exposure risk at environmental levels that should be a cause for concern.


Assuntos
Cosméticos , Exposição Ambiental , Humanos , Adulto , Adulto Jovem , Medição de Risco , Feminino , Masculino , Adolescente , Cosméticos/análise , Exposição Ambiental/estatística & dados numéricos , Exposição Ambiental/análise , Pequim , Poluentes Ambientais/análise , Benzofenonas/urina , Monitoramento Ambiental
2.
BMC Musculoskelet Disord ; 25(1): 650, 2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-39160506

RESUMO

PURPOSE: Implanted devices used in metastatic spine tumor surgery (MSTS) include pedicle screws, fixation plates, fixation rods, and interbody devices. A material to be used to fabricate any of these devices should possess an array of properties, which include biocompatibility, no toxicity, bioactivity, low wear rate, low to moderate incidence of artifacts during imaging, tensile strength and modulus that are comparable to those of cortical bone, high fatigue strength/long fatigue life, minimal or no negative impact on radiotherapy (RT) planning and delivery, and high capability for fusion to the contiguous bone. The shortcomings of Ti6Al4V alloy for these applications with respect to these desirable properties are well recognized, opening the field for an investigation about novel biomaterials that could replace the current gold standard. Previously published reviews on this topic have exhibited significant shortcomings in the studies they included, such as a small, heterogenous sample size and the lack of a cost-benefit analysis, extremely useful to understand the practical possibility of applying a novel material on a large scale. Therefore, this review aims to collect information about the clinical performance of these biomaterials from the most recent literature, with the objective of deliberating which could potentially be better than titanium in the future, with particular attention to safety, artifact production and radiotherapy planning interference. The significant promise showed by analyzing the clinical performance of these devices warrants further research through prospective studies with a larger sample size also taking into account each aspect of the production and use of such materials. METHODS: The Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines were used to improve the reporting of the review. The search was performed from March 2022 to September 2023. RESULTS: At the end of the screening process, 20 articles were considered eligible for this study. Polyetheretherketone (PEEK), Carbon-fibre reinforced polyetheretherketone (CFR-PEEK), long carbon fiber reinforced polymer (LCFRP), Polymethylmethacrylate (PMMA), and carbon screw and rods were used in the included studies. CONCLUSION: CFR-PEEK displays a noninferior safety and efficacy profile to titanium implanted devices. However, it also has other advantages. By decreasing artifact production, it is able to increase detection of local tumor recurrence and decrease radiotherapy dose perturbation, ultimately bettering prognosis for patients necessitating adjuvant treatment. Nonetheless, its drawbacks have not been explored fully and still require further investigation in future studies. This does not exclude the fact that CFR-PEEK could be a valid alternative to titanium in the near future.


Assuntos
Neoplasias da Coluna Vertebral , Titânio , Humanos , Neoplasias da Coluna Vertebral/cirurgia , Neoplasias da Coluna Vertebral/radioterapia , Neoplasias da Coluna Vertebral/secundário , Ligas , Materiais Biocompatíveis , Polímeros , Resultado do Tratamento , Cetonas , Benzofenonas , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Parafusos Pediculares
3.
BMC Oral Health ; 24(1): 946, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39143630

RESUMO

BACKGROUND: Restorative treatment options for edentulous patients range from traditional dentures to fixed restorations. The proper selection of materials greatly influences the longevity and stability of fixed restorations. Most prosthetic parts are frequently fabricated from titanium. Ceramics (e.g. zirconia) and polymers (e.g. PEEK and BIOHPP) have recently been included in these fabrications. The mandibular movement produces complex patterns of stress and strain. Mandibular fractures may result from these stresses and strains exceeding the critical limits because of the impact force from falls or accidents. Therefore, it is necessary to evaluate the biomechanical behavior of the edentulous mandible with different restorations under different loading situations. OBJECTIVE: This study analyzes the biomechanical behavior of mandibles after four prosthetic restorations for rehabilitation under normal and impact loading scenarios. MATERIAL AND METHODS: The mandibular model was constructed with a fixed restoration, which was simulated using various materials (e.g. Titanium, Zirconia & BIOHPP), under frontal bite force, maximum intercuspation, and chin impact force. From the extraction of tensile and compressive stresses and strains, as well as the total deformation of mandible segments, the biomechanical behavior and clinical situations were studied. RESULTS: Under frontal bite, the anterior body exhibited the highest tensile (60.34 MPa) and compressive (108.81 MPa) stresses using restoration 4, while the condyles and angles had the lowest tensile (7.12 MPa) and compressive (12.67 MPa) stresses using restoration 3. Under maximum intercuspation, the highest tensile (40.02 MPa) and compressive (98.87 MPa) stresses were generated on the anterior body of the cortical bone using restoration 4. Additionally, the lowest tensile (7.7 MPa) and compressive (10.08 MPa) stresses were generated on the condyles and angles, respectively, using restoration 3. Under chin impact, the highest tensile (374.57 MPa) and compressive (387.3 MPa) stresses were generated on the anterior body using restoration 4. Additionally, the lowest tensile (0.65 MPa) and compressive (0.57 MPa) stresses were generated on the coronoid processes using restoration 3. For all loading scenarios, the anterior body of the mandible had the highest stress and strain values compared with the other segments. Compared to the traditional titanium restoration.2, restoration.1(zirconia) increases the tensile and compressive stresses and strains on the mandibular segments, in contrast to restoration.3 (BIOHPP). In addition, zirconia implants exhibited higher displacements than the other implants. CONCLUSION: In the normal loading scenario, the tensile and compressive stresses and strains on the mandible were within the allowable limits when all restorations were used. Under the chin impact loading scenario, the anterior body of the mandible was damaged by restorations 1 and 4.


Assuntos
Força de Mordida , Mandíbula , Estresse Mecânico , Titânio , Zircônio , Humanos , Fenômenos Biomecânicos , Materiais Dentários/química , Polietilenoglicóis , Polímeros , Arcada Edêntula/reabilitação , Benzofenonas , Cetonas , Resistência à Tração , Análise de Elementos Finitos , Análise do Estresse Dentário , Força Compressiva , Planejamento de Dentadura
4.
Zhongguo Gu Shang ; 37(7): 676-83, 2024 Jul 25.
Artigo em Chinês | MEDLINE | ID: mdl-39104068

RESUMO

OBJECTIVE: To investigate the effect of Polyetheretherketone (PEEK) rod semi-rigid pedicle screw fixation system in lumbar spine non-fusion surgery. METHODS: A total of 74 patients with tow-level lumbar degenerative diseases who underwent surgery from March 2017 to December 2019 were divided into PEEK rod group and titanium rod group. In the PEEK rod group, there were 34 patients, including 13 males and 21 females, aged from 51 to 79 years old with an average of (62.4±6.8) years old;There were 1 patient of L1-L3 segments, 7 patients of L2-L4 segments, 20 patients of L3-L5 segments and 6 patients of L4-S1 segments. In the titanium rod group, there were 40 patients, including 17 males and 23 females, aged from 52 to 81 years old with an average of (65.2±7.3) years old;There were 3 patient of L1-L3 segments, 11 patients of L2-L4 segments, 19 patients of L3-L5 segments and 7 patients of L4-S1 segments. The general conditions of operation, such as operation time, intraoperative blood loss, postoperative drainage was recorded. The visual analogue scale (VAS) for low back pain and Oswestry disability index (ODI) were compared in preoperatively and postoperatively(3 months, 12 months and last follow-up) between two groups. The change of range of motion (ROM) was observed by flexion and extension x-ray of lumbar. RESULTS: All patients successfully completed the operation. The follow-up time ranged from 22 to 34 months with an average of(26.8±5.6) months. The operative time (142.2±44.7) min and intraoperative blood loss(166.5±67.4)ml in PEEK group were lower than those in titanium group [(160.7±57.3) min、(212.8±85.4) ml](P<0.05). There was no significant differences in postoperative drainage between the two groups (P>0.05). At the final follow-up visit, in PEEK group and titanium group VAS of low back pain[(0.8±0.4) points vs (1.0±0.5) points], VAS for leg pain [ (0.7±0.4) points vs (0.8±0.5) points] and ODI [(9.8±1.6)% vs (12.1±1.5)%] were compared with preoperative [ (5.8±1.1) points vs (6.0±1.1)points], [ (7.2±1.7) points vs (7.0±1.6) points], [(68.5±8.9)% vs(66.3±8.2)%] were significantly different(P<0.05). There was no significant difference in VAS scores between the two groups at each postoperative time point (P>0.05). At 3 months after surgery, there was no difference in ODI between the two groups (P>0.05). There were significant differences in ODI between PEEK group and titanium rod group at 12 months [(15.5±2.1)% vs (18.4±2.4)%] and at the last follow-up [(9.8±1.6)% vs (12.1±1.5)%] (P<0.05). The total range of motion (ROM) of lumbar decreased in both groups after surgery. At 12 months after surgery and the last follow-up, the PEEK group compared with the titanium rod group, the total range of motion of lumbar was statistically significant (P<0.05). The range of motion (ROM) of the fixed segments decreased in both groups after surgery. The ROM of the fixed segments in PEEK group decreased from (9.5±4.6)° to (4.1±1.9)° at the last follow-up (P<0.05), which in the titanium rod group was decreased from (9.8±4.3)°to (0.9±0.5)° at the last follow-up (P<0.05). The range of motion (ROM) of upper adjacent segment increased in both groups, there was statistical significance in the ROM of upper adjacent segment between the two groups at 12 months after surgery and the last follow-up, (P<0.05). There was no screw loosening and broken rods in both groups during the follow-up period. CONCLUSION: The PEEK rod semi-rigid pedicle screw internal fixation system used in lumbar non-fusion surgery can retain part of the mobility of the fixed segment, showing comparable short-term clinical efficacy to titanium rod fusion. PEEK rod semi-rigid pedicle screw internal fixation system is a feasible choice for the treatment of lumbar spine degenerative diseases, and its long-term efficacy needs further follow-up observation.


Assuntos
Benzofenonas , Cetonas , Vértebras Lombares , Parafusos Pediculares , Polietilenoglicóis , Polímeros , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Vértebras Lombares/cirurgia , Idoso de 80 Anos ou mais
5.
Clin Oral Investig ; 28(9): 468, 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39105859

RESUMO

OBJECTIVE: this study aimed to digitally compare wear behavior and retention between PEEK and nylon retentive inserts used in locator-retained, mandibular implant overdentures when attachment design and size were standardized. MATERIALS AND METHODS: A total of sixty-four inserts (32 PEEK and 32 nylon inserts); were picked-up in implant overdentures. Overdentures of both groups were submerged in artificial saliva and mounted to chewing simulator. After 480,000 chewing cycles (equivalent to 2 years of clinical use) all inserts were scanned by scanning electron microscope (SEM), then all acquired images were digitally analyzed by software to detect and compare quantitative and qualitative changes of inserts in both groups. On the other hand, retention of both groups was measured by universal testing machine and the collected data was statistically analyzed using one-way Analysis of Variance (ANOVA) test with significance level set at P ≤ 0.05. RESULTS: PEEK inserts showed significantly higher mean retentive values compared to the nylon inserts in the control group. Also, PEEK retentive inserts exhibited statistically lower mean wear values than the control group P ≥ 0.000. Qualitative investigation revealed significant and more pronounced changes in the surface roughness of nylon inserts compared to PEEK ones. CONCLUSIONS: Regarding retention, wear behavior and dimension stability, PEEK can be recommended as retentive insert material in cases of locator-retained mandibular implant overdentures. CLINICAL RELEVANCE: PEEK inserts offer enhanced retention, reduced wear, and greater dimensional stability over two years time interval. Clinically, this reduces prosthodontic maintenance and adjustments, improving patient satisfaction and long-term prosthetic success.


Assuntos
Benzofenonas , Prótese Dentária Fixada por Implante , Retenção de Dentadura , Revestimento de Dentadura , Cetonas , Teste de Materiais , Microscopia Eletrônica de Varredura , Nylons , Polietilenoglicóis , Polímeros , Propriedades de Superfície , Cetonas/química , Polietilenoglicóis/química , Humanos , Técnicas In Vitro , Mandíbula , Desgaste de Restauração Dentária , Planejamento de Dentadura , Análise do Estresse Dentário , Saliva Artificial
6.
Sci Rep ; 14(1): 19364, 2024 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-39169088

RESUMO

The incidence of spondylodiscitis has witnessed a significant increase in recent decades. Surgical intervention becomes necessary in case of bone destruction to remove infected tissue and restore spinal stability, often involving the implantation of a cage. Despite appropriate treatment, relapses occur in up to 20 percent of cases, resulting in substantial economic and social burdens. The formation of biofilm has been identified as a major contributor to relapse development. Currently, there is no consensus among German-speaking spinal surgeons or in the existing literature regarding the preferred choice of material to minimize relapse rates. Thus, the objective of this study is to investigate whether certain materials used in spinal implants exhibit varying degrees of susceptibility to bacterial attachment, thereby providing valuable insights for improving treatment outcomes.Eight cages of each PEEK, titanium-coated PEEK (Ti-PEEK), titanium (Ti), polyetherketoneketone (PEKK), tantalum (Ta) and antibiotic-loaded bone cement were incubated with 20% human plasma for 24 h. Subsequently, four implants were incubated with S. aureus for 24 h or 48 h each. The biofilm was then removed by sonication and the attained solution plated for Colony Forming Units (CFU) counting. Scanning electron microscopy was used to confirm bacterial attachment. The CFUs have been compared directly and in relation to the cages surface area. The surface area of the implants was PEEK 557 mm2, Ti-PEEK 472 mm2, Ti 985 mm2, PEKK 594 mm2, Ta 706 mm2, bone cement 123 mm2. The mean CFU count per implant and per mm2 surface area after 24 h and after 48 h was calculated. Bone cement was found to have significantly more CFUs per mm2 surface area than the other materials tested. When comparing the CFU count per implant, bone cement was statistically significantly more prone to biofilm formation than PEEK after 48 h. There was no statistical significance between the other materials when comparing both CFU count per mm2 surface area and CFU count per implant. The electron microscopic analysis showed the attachment of the bacteria, as well as production of extracellular polymeric substances (EPS) as a sign for beginning biofilm formation. Antibiotic-loaded bone cement has shown statistically significantly more bacterial attachment than the other examined materials. No difference was found between the other materials regarding bacterial attachment after 24 h and 48 h. Proposed hypotheses for further studies include testing whether differences become apparent after longer incubation or with different pathogens involved in the pathogenesis of pyogenic spondylodiscitis.


Assuntos
Biofilmes , Discite , Próteses e Implantes , Staphylococcus aureus , Titânio , Biofilmes/crescimento & desenvolvimento , Staphylococcus aureus/fisiologia , Staphylococcus aureus/efeitos dos fármacos , Humanos , Discite/microbiologia , Discite/cirurgia , Próteses e Implantes/microbiologia , Infecções Estafilocócicas/microbiologia , Polímeros/química , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Aderência Bacteriana , Cimentos Ósseos , Benzofenonas , Polietilenoglicóis/química , Cetonas
7.
BMC Oral Health ; 24(1): 904, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39112986

RESUMO

BACKGROUND: Multi-rooted teeth with extensive dental defects often face challenges in stability and biomechanical failure. High-performance polymer PEEK materials, with properties closer to dentin, show promise in reducing stress concentration and preserving tooth structure. This report aimed to explore the use of a highly retentive polyetheretherketone (PEEK) for manufacturing custom-made split post and core for the restoration of grossly destroyed endodontically treated molars. CLINICAL CONSIDERATIONS: A 40-year-old female patient presented with complaints of loss of tooth substance in the posterior mandibular tooth. This case involved the digital design and fabrication of PEEK split post and core to restore multirooted molar with insufficient dental tissue remnants. The restorations were evaluated over a 3-year follow-up using the World Federation criteria (FDI). The restoration was clinically evaluated through intraoral examination, radiographic assessment, and subjective patient satisfaction, and was deemed clinically good according to FDI criteria. CONCLUSION: The outstanding mechanical properties of PEEK, coupled with the structure of the split post, provide an effective treatment option for weakened multirooted teeth. Simultaneously, the restoration configuration effectively addressed the challenge of varying postinsertion directions, and the interlocking mechanism between the primary and auxiliary posts enhanced the stability of the post and core.


Assuntos
Benzofenonas , Cetonas , Dente Molar , Polietilenoglicóis , Polímeros , Humanos , Feminino , Adulto , Dente Molar/cirurgia , Técnica para Retentor Intrarradicular , Seguimentos , Planejamento de Prótese Dentária , Dente não Vital/cirurgia , Desenho Assistido por Computador
8.
BMC Oral Health ; 24(1): 910, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39112988

RESUMO

BACKGROUND: There is insufficient evidence recommending a framework material and a CAD/CAM manufacturing technique for mandibular implant-supported prostheses. The study objective was to evaluate the clinical application of different materials and construction techniques used for mandibular All-on-4 prosthesis on circumferential peri-implant bony changes after 5 years. METHODS: Thirty-six male patients with all-on-4 mandibular implant-supported prostheses were recalled and divided into three groups. Group PK (patients with frameworks milled from PEEK blocks), Group PSM (patients with frameworks milled from soft metal blocks), and Group SLM (patients with frameworks constructed with additive manufacturing; selective laser melting). The circumferential bone level on all implant faces was assessed with a CBCT. Two-way repeated measures ANOVA was used to compare vertical bone loss (VBL) and horizontal bone loss (HBL) between different groups, implant positions, and observation times followed by Tukey's multiple comparisons. RESULTS: For all observation times, there was a significant difference in VBL between groups for both anterior and posterior implants (P < .001). For anterior implants, group PSM showed the lowest VBL while group PK showed the highest for anterior and posterior implants. For all groups, HBL significantly increased after 5 years for both anterior and posterior implants (P < .001). For anterior implants, group PSM showed the highest HBL. For posterior implants, group PK and SLM showed the highest. CONCLUSION: Within the study's limitations, mandibular implant-supported fixed frameworks fabricated with either milling from PEEK or soft metal blocks, or additive manufacturing (laser melting technology) exhibited significant vertical and horizontal bone height changes after 5 years. CLINICAL TRIAL REGISTRY NUMBER: (NCT06071689) (11/10/2023).


Assuntos
Perda do Osso Alveolar , Desenho Assistido por Computador , Prótese Dentária Fixada por Implante , Mandíbula , Humanos , Masculino , Pessoa de Meia-Idade , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Perda do Osso Alveolar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Planejamento de Prótese Dentária , Idoso , Benzofenonas , Adulto , Implantes Dentários , Polímeros
9.
BMC Ophthalmol ; 24(1): 369, 2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39180057

RESUMO

BACKGROUND: Topical non-steroidal anti-inflammatory drugs have the potential to reduce treatment burden and improve outcomes of anti-VEGF therapy for a number of retinal disorders, including neovascular age-related macular degeneration, diabetic macular edema, and retinal vein occlusions. In this review, we focused on the advantages of topical bromfenac as an adjunct to intravitreal anti-VEGF therapy in VEGF-driven maculopathies. METHODS: Cochrane Library, PubMed, and EMBASE were systematically reviewed to identify the relevant studies of neovascular age-related macular degeneration, diabetic macular edema, macular edema associated with retinal vein occlusion, myopic choroidal neovascularization, and radiation maculopathy which reported changes in central retinal thickness, visual acuity, and the number of anti-VEGF injections needed when anti-VEGF therapy was combined with topical bromfenac. RESULTS: In total, ten studies evaluating bromfenac as an adjunct to anti-VEGF therapy were identified. Five studies were included in meta-analysis of the number of injections and five studies were included in the analysis of changes in central retinal thickness. A statistically significantly lower number of intravitreal injections (p = 0.005) was required when bromfenac was used as an adjunct to anti-VEGF therapy compared to anti-VEGF monotherapy with pro re nata regimen. At the same time, eyes receiving bromfenac as an adjunct to anti-VEGF therapy demonstrated non-inferior outcomes in central retinal thickness (p = 0.07). Except for one study which reported better visual outcomes with combined treatment, no difference in visual acuity or clinically significant adverse effects were reported. CONCLUSIONS: This literature review and meta-analysis showed that topical bromfenac can be considered as a safe adjunct to anti-VEGF therapy with a potential to reduce the treatment burden with anti-VEGF drugs requiring frequent injections without compromising improvement of central retinal thickness or visual acuity.


Assuntos
Inibidores da Angiogênese , Anti-Inflamatórios não Esteroides , Benzofenonas , Bromobenzenos , Fator A de Crescimento do Endotélio Vascular , Humanos , Administração Tópica , Inibidores da Angiogênese/administração & dosagem , Anti-Inflamatórios não Esteroides/administração & dosagem , Benzofenonas/administração & dosagem , Bromobenzenos/administração & dosagem , Injeções Intravítreas , Edema Macular/tratamento farmacológico , Soluções Oftálmicas/administração & dosagem , Doenças Retinianas/tratamento farmacológico , Doenças Retinianas/fisiopatologia , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Acuidade Visual
10.
Jt Dis Relat Surg ; 35(3): 483-490, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-39189556

RESUMO

OBJECTIVES: The aim of the present meta-analysis was to compare the efficacy and safety of the carbon fiber-reinforced polyetheretherketone (CFR-PEEK) and titanium plate for the treatment of proximal humeral fractures (PHFs) from clinical comparative trials. MATERIALS AND METHODS: A comprehensive search of English databases was carried out, such as PubMed, Web of Science, ScienceDirect, Springer and Cochrane Library databases. The RevMan version 5.1 software was applied for statistical analysis, and the mean difference (MD) and risk difference (RD) as the combined variables, and "95%" as the confidence interval (CIs). RESULTS: One randomized-controlled trial and five retrospective controlled studies including 282 PHFs were considered eligible and finally included. Meta-analysis demonstrated that there were significant differences in Constant score (CS) (MD=9.23; 95% CI: 5.02, 13.44; p<0.0001), anterior elevation (MD=18.83; 95% CI: 6.27, 31.38; p=0.003), lateral elevation (MD=18.42; 95% CI: 3.64, 33.19; p=0.01) and adduction (MD=3.53; 95% CI: 0.22, 6.84; p=0.04). No significant differences were observed regarding Constant score compared to the contralateral shoulder, Oxford Shoulder Score, internal rotation, external rotation, screw perforation and cutout, varus/valgus malalignment, humeral head collapse/necrosis, implant removal, and revision surgery between the two groups. CONCLUSION: Compared to titanium plate, CFR-PEEK plate showed better Constant score, anterior elevation, lateral elevation and adduction in treating PHFs. The complications are comparable to those achieved with conventional titanium plates.


Assuntos
Benzofenonas , Placas Ósseas , Fibra de Carbono , Fixação Interna de Fraturas , Cetonas , Polietilenoglicóis , Polímeros , Fraturas do Ombro , Titânio , Humanos , Fraturas do Ombro/cirurgia , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Resultado do Tratamento , Carbono
11.
ACS Synth Biol ; 13(8): 2587-2599, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-39110782

RESUMO

Genetic code expansion (GCE) is a powerful strategy that expands the genetic code of an organism for incorporating noncanonical amino acids into proteins using engineered tRNAs and aminoacyl-tRNA synthetases (aaRSs). While GCE has opened up new possibilities for synthetic biology, little is known about the potential side effects of exogenous aaRS/tRNA pairs. In this study, we investigated the impact of exogenous aaRS and amber suppressor tRNA on gene expression in Escherichia coli. We discovered that in DH10ß ΔcyaA, transformed with the F1RP/F2P two-hybrid system, the high consumption rate of cellular adenosine triphosphate by exogenous aaRS/tRNA at elevated temperatures induces temperature sensitivity in the expression of genes regulated by the cyclic AMP receptor protein (CRP). We harnessed this temperature sensitivity to create a novel biological AND gate in E. coli, responsive to both p-benzoylphenylalanine (BzF) and low temperature, using a BzF-dependent variant of E. coli chorismate mutase and split subunits of Bordetella pertussis adenylate cyclase. Our study provides new insights into the unexpected effects of exogenous aaRS/tRNA pairs and offers a new approach for constructing a biological logic gate.


Assuntos
Aminoácidos , Aminoacil-tRNA Sintetases , Escherichia coli , RNA de Transferência , Temperatura , Escherichia coli/genética , Escherichia coli/metabolismo , Aminoacil-tRNA Sintetases/genética , Aminoacil-tRNA Sintetases/metabolismo , Aminoácidos/metabolismo , RNA de Transferência/genética , RNA de Transferência/metabolismo , Proteínas de Escherichia coli/genética , Proteínas de Escherichia coli/metabolismo , Código Genético , Proteína Receptora de AMP Cíclico/metabolismo , Proteína Receptora de AMP Cíclico/genética , Biologia Sintética/métodos , Corismato Mutase/genética , Corismato Mutase/metabolismo , Fenilalanina/metabolismo , Fenilalanina/análogos & derivados , Trifosfato de Adenosina/metabolismo , Regulação Bacteriana da Expressão Gênica , Benzofenonas
12.
Sci Rep ; 14(1): 18681, 2024 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-39134579

RESUMO

The interaction of active substances with molecular structures in stratum corneum (SC) is crucial for the efficacy and safety of cosmetic formulations and topical drugs. However, the molecular architecture of SC is highly complex and methods to unambiguously localize exogenous molecules within SC are lacking. Consequently, little is known about the distribution of actives within SC, and proposed penetration mechanisms through SC are typically limited to simple diffusion via a tortuous (lipid only) or transverse (across corneocytes and lipid matrix) pathway. In this work, 3D mass spectrometry imaging is used to determine the spatial distributions of four active substances at subcellular resolution in SC, including partitioning between the corneocytes and the intercellular lipid matrix. The results indicate that caffeine, 2-methyl resorcinol and oxybenzone are homogeneously distributed in the corneocytes but largely absent in the lipid matrix, despite considerable differences in lipophilicity. In contrast, the distribution- of jasmonic acid derivative is more inhomogeneous and indicates considerable localization to both the lipid phase and the corneocytes.


Assuntos
Epiderme , Epiderme/metabolismo , Lipídeos/química , Lipídeos/análise , Humanos , Cafeína/metabolismo , Animais , Benzofenonas/metabolismo , Resorcinóis/metabolismo , Resorcinóis/farmacologia , Espectrometria de Massas
13.
ACS Appl Mater Interfaces ; 16(33): 44127-44138, 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39119797

RESUMO

The repair of large bone defects poses a significant challenge in orthopedics. Polyetheretherketone (PEEK) is a promising bone substitute, while it suffers a lack of bioactivity. Although several studies have been performed to further improve the bioactivities of PEEK by various surface modifications, PEEK offering long-term, multifaceted biofunctionalities remains still desired. In this study, we introduced metal-organic frameworks (MOFs), specifically ZIF-8 loaded with celecoxib (ZIF-8(CEL)), onto the PEEK surface through dopamine adhesion. The resulting PEEK@ZIF-8(CEL) aims to achieve long-term stable release of Zn ions and CEL for enhanced bone integration. Material characterization and biological experiments confirmed the successful integration of ZIF-8(CEL) onto PEEK and its positive biomedical effects, including creating a positive bone immunological environment and promoting bone growth. This study demonstrates the potential of PEEK@ZIF-8(CEL) as a novel repair material for large bone defects, offering a promising alternative in orthopedic applications.


Assuntos
Benzofenonas , Cetonas , Polietilenoglicóis , Polímeros , Benzofenonas/química , Polímeros/química , Cetonas/química , Polietilenoglicóis/química , Animais , Camundongos , Estruturas Metalorgânicas/química , Substitutos Ósseos/química , Substitutos Ósseos/uso terapêutico , Substitutos Ósseos/farmacologia , Zinco/química , Osteogênese/efeitos dos fármacos
14.
J Biomed Mater Res B Appl Biomater ; 112(8): e35463, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39115314

RESUMO

Secondary healing of fractured bones requires an application of an appropriate fixator. In general, steel or titanium devices are used mostly. However, in recent years, composite structures arise as an attractive alternative due to high strength to weight ratio and other advantages like, for example, radiolucency. According to Food and Drug Administration (FDA), the only unidirectionally reinforced composite allowed to be implanted in human bodies is carbon fiber (CF)-reinforced poly-ether-ether-ketone (PEEK). In this work, the healing process of long bone assembled with CF/PEEK plates with cross- and angle-ply lay-up configurations is studied in the framework of finite element method. The healing is simulated by making use of the mechanoregulation model basing on the Prendergast theory. Cells transformation is determined by the octahedral shear strain and interstitial fluid velocity. The process runs iteratively assuming single load cycle each day. The fracture is subjected to axial and transverse forces. In the computations, the Abaqus program is used. It is shown that the angle-ply lamination scheme of CF/PEEK composite seems to provide better conditions for the transformation of the soft callus into the bone tissue.


Assuntos
Benzofenonas , Placas Ósseas , Fibra de Carbono , Consolidação da Fratura , Cetonas , Polietilenoglicóis , Polímeros , Cetonas/química , Fibra de Carbono/química , Polietilenoglicóis/química , Polímeros/química , Humanos , Carbono/química , Fraturas Ósseas , Análise de Elementos Finitos
15.
Chin J Dent Res ; 27(2): 161-168, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38953481

RESUMO

OBJECTIVE: To evaluate the effect of different adhesives and veneering resins on the shear bond strength (SBS) of polyetheretherketone (PEEK). METHODS: A total of 138 PEEK specimens were randomly divided into 6 groups according to adhesive material application: Control (C, no application), Adhese Universal (A) (Ivoclar Vivadent, Schaan, Liechtenstein), Gluma Bond Universal (G) (Heraeus Kulzer, South Bend, IN, USA), G-PremioBOND (P) (GC Corporation, Tokyo, Japan), Single Bond Universal (S) (3M, Saint Paul, MN, USA) and visio.link (V) (Bredent, Senden, Germany). Each adhesive group was divided into two subgroups according to the type of veneering material: Estenia direct composite (D) and Gradia Plus indirect composite (IN) (both GC Corporation). After the veneering process, the specimens were aged by thermal cycling. Kruskal-Wallis and Mann-Whitney U tests were used for SBS analysis (P < 0.05). RESULTS: The highest SBS results were obtained in the VIN group, followed by the VD, PD, GIN, AIN, AD, SIN, SD, PIN, GD, CIN and CD groups, respectively (P = 0.001). There were no significant differences in terms of the type of veneering composite when the same adhesive was applied (P > 0.05), except for Gluma Bond Universal (P = 0.009). All the adhesives tested showed clinically acceptable SBS results. CONCLUSION: Visio.link offered the highest adhesion to PEEK, whereas the tested universal adhesives may be used as an alternative to visio.link in clinical settings. It was determined that changing the veneer type has no statistical difference when the same adhesive material is used.


Assuntos
Benzofenonas , Resinas Compostas , Facetas Dentárias , Cetonas , Polietilenoglicóis , Polímeros , Resistência ao Cisalhamento , Cetonas/química , Teste de Materiais , Colagem Dentária , Humanos , Cimentos de Resina , Análise do Estresse Dentário , Bis-Fenol A-Glicidil Metacrilato
16.
Colloids Surf B Biointerfaces ; 242: 114067, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38981327

RESUMO

Today, it would be difficult for us to live a full life without polymers, especially in medicine, where its applicability is constantly expanding, giving satisfactory results without any harm effects on health. This study focused on the formation of hexagonal domains doped with AgNPs using a KrF excimer laser (λ=248 nm) on the polyetheretherketone (PEEK) surface that acts as an unfailing source of the antibacterial agent - silver. The hexagonal structure was formed with a grid placed in front of the incident laser beam. Surfaces with immobilized silver nanoparticles (AgNPs) were observed by AFM and SEM. Changes in surface chemistry were studied by XPS. To determine the concentration of released Ag+ ions, ICP-MS analysis was used. The antibacterial tests proved the antibacterial efficacy of Ag-doped PEEK composites against Escherichia coli and Staphylococcus aureus as the most common pathogens. Because AgNPs are also known for their strong toxicity, we also included cytotoxicity tests in this study. The findings presented here contribute to the advancement of materials design in the biomedical field, offering a novel starting point for combating bacterial infections through the innovative integration of AgNPs into inert synthetic polymers.


Assuntos
Antibacterianos , Benzofenonas , Escherichia coli , Nanopartículas Metálicas , Testes de Sensibilidade Microbiana , Polietilenoglicóis , Polímeros , Prata , Staphylococcus aureus , Prata/química , Prata/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Polímeros/química , Polímeros/farmacologia , Escherichia coli/efeitos dos fármacos , Staphylococcus aureus/efeitos dos fármacos , Polietilenoglicóis/química , Polietilenoglicóis/farmacologia , Benzofenonas/química , Benzofenonas/farmacologia , Nanopartículas Metálicas/química , Propriedades de Superfície , Cetonas/química , Cetonas/farmacologia , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Humanos , Equipamentos e Provisões/microbiologia , Tamanho da Partícula
17.
Sci Total Environ ; 948: 174784, 2024 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-39009150

RESUMO

This study investigates the presence and impact of UV filters in Posidonia oceanica meadows in Formentera, a Mediterranean tourist hotspot. It highlights the distribution of inorganic (TiO2 and ZnO) and organic UV filters (UVFs) in different environmental matrices, their accumulation in seagrass tissues and their impact on the seagrass health. In the overlying and canopy waters of P. oceanica, Zn concentrations surpassed Ti, with three organic UVFs (benzophenone-3 [BP-3], avobenzone and homosalate [HMS]) consistently detected. Ti concentrations were generally higher than Zn in rhizosphere sediments, along with recurrent presence of octocrylene, HMS, 2-ethylhexyl methoxycinnamate (EHMC), and 4-methylbenzylidene camphor (4-MBC). Maximum Zn concentrations were found in canopy waters (3052.9 ng L-1). Both Ti and Zn were found in all P. oceanica tissues and leaf epiphytes across all study sites. Additional UVFs like octocrylene, avobenzone, and BP-8 were also detected in P. oceanica tissues and epiphytes. Elevated levels of octocrylene in leaf epiphytes (2112.1 ng g-1 dw) and avobenzone in leaves (364.2 ng g-1 dw) and leaf epiphytes (199.6 ng g-1 dw) were observed in the Port of La Savina, the island's main entry port. Octocrylene concentrations (up to 2575 ng g-1 dw) in rhizosphere sediments near sewage discharge points exceeded reported maxima, highlighting wastewater treatment plants as significant sources of organic UVFs. Correlational analyses suggested that the accumulation of octocrylene, avobenzone, and BP-3 negatively impacted P. oceanica's conservation status, affecting global density, density at 100 % cover, and leaf morphometry. Positive correlations were observed between leaf polyphenols (antioxidants) and concentrations of avobenzone, benzophenone-8 (BP-8), and BP-3, indicating potential oxidative stress induced by UVFs in P. oceanica. Our study underscores the pervasive presence of UV filters in P. oceanica habitats, with implications for seagrass health and conservation, especially in areas of high tourism and sewage discharge.


Assuntos
Alismatales , Monitoramento Ambiental , Protetores Solares , Poluentes Químicos da Água , Protetores Solares/análise , Poluentes Químicos da Água/análise , Mar Mediterrâneo , Benzofenonas/análise , Acrilatos
18.
ACS Appl Mater Interfaces ; 16(30): 38989-39004, 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39034661

RESUMO

Implant-associated infections and excessive immune responses are two major postsurgical issues for successful implantation. However, conventional strategies including antibiotic treatment and inflammatory regulation are always compromised due to the comodification of various biochemical agents and instances of functional interference. It is imperative to provide implant surfaces with satisfactory antibacterial and anti-inflammatory properties. Here, a dual-effect nanostructured polyetheretherketone (PEEK) surface (NP@PDA/Zn) with bionic mechano-bactericidal nanopillars and immobilized immunomodulatory Zn2+ is designed. The constructed hybrid nanopillars display remarkable antibacterial performance against Gram-negative and Gram-positive strains through the synergy of physical and chemical bactericidal effects imposed by nanopillars and Zn2+. Meanwhile, the immunoregulatory property is evaluated through the investigation of macrophage polarization both in vitro and in vivo, and the results reveal that NP@PDA/Zn could downregulate the expression of M1-related cytokines and decrease the M1 macrophage recruitment to lower the inflammatory response. Notably, the surface exhibited exceptional biocompatibility with discerning biocidal activity between bacterial and mammalian cells and antioxidant performance that effectively scavenges ROS, minimizing potential cytotoxicity. Taken together, NP@PDA/Zn presents a convenient and promising strategy of combining synergistic bactericidal activity and inflammatory regulation without any mutual interference, which can support the development of multifunctional implant-associated materials.


Assuntos
Antibacterianos , Anti-Inflamatórios , Benzofenonas , Nanopartículas Metálicas , Nanoestruturas , Polímeros , Benzofenonas/química , Benzofenonas/farmacologia , Polímeros/química , Polímeros/farmacologia , Nanoestruturas/química , Nanopartículas Metálicas/química , Sinergismo Farmacológico , Antibacterianos/química , Antibacterianos/farmacologia , Anti-Inflamatórios/química , Anti-Inflamatórios/farmacologia , Staphylococcus aureus/efeitos dos fármacos , Escherichia coli/efeitos dos fármacos , Animais , Camundongos , Células RAW 264.7 , Feminino , Camundongos Endogâmicos BALB C , Propriedades de Superfície , Zinco/química , Zinco/farmacologia , Implantação de Prótese , Sobrevivência Celular/efeitos dos fármacos
19.
Anal Chem ; 96(32): 12991-12998, 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39075986

RESUMO

With the increasing demand for trace sample analysis, injecting trace samples into liquid chromatography-mass spectrometry (LC-MS) systems with minimal loss has become a major challenge. Herein, we describe an in situ LC-MS analytical probe, the Falcon probe, which integrates multiple functions of high-pressure sample injection without sample loss, high-efficiency LC separation, and electrospray. The main body of the Falcon probe is made of stainless steel and fabricated by the computer numerical control (CNC) technique, which has ultrahigh mechanical strength. By coupling a nanoliter-scale droplet reactor made of polyether ether ketone (PEEK) material, the Falcon probe-based LC-MS system was capable of operating at mobile-phase pressures up to 800 bar, which is comparable to those of conventional ultraperformance liquid chromatography (UPLC) systems. Using the probe pressing microamount in situ (PPMI) injection approach, the Falcon probe-based LC-MS system showed high separation efficiency and good repeatability with relative standard deviations (RSDs) of retention time and peak area of 1.8% and 9.9%, respectively, in peptide mixture analysis (n = 6). We applied this system to the analysis of a trace amount of 200 pg of HeLa protein digest and successfully identified an average of 766 protein groups (n = 5). By combining in situ sample pretreatment at the nanoliter range, we further applied the present system in single-cell proteomic analysis, and 241 protein groups were identified in single 293 cells, which preliminarily demonstrated its potential in the analysis of trace amounts of samples with complex compositions.


Assuntos
Pressão , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Nanotecnologia , Polietilenoglicóis/química , Peptídeos/análise , Cromatografia Líquida de Alta Pressão , Células HeLa , Benzofenonas/análise , Benzofenonas/química , Polímeros/química , Cetonas/química , Cetonas/análise , Proteômica/métodos
20.
J Indian Prosthodont Soc ; 24(3): 245-251, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38946507

RESUMO

AIM: Synthetic inorganic materials are commonly used as reinforcing agents in polyetheretherketone (PEEK) composite, whereas natural organic plant-based reinforcing agents are negligible. Surface hardness, roughness, and wettability are indicative factors of osseointegration behavior to be used as an implant material. This study evaluated micro surface hardness (MSH), nano surface hardness (NSH), surface roughness (SR), and contact angle (CA) of PEEK-Azadirachta indica reinforced at 10 wt%, 20 wt%, and 30 wt%. SETTINGS AND DESIGN: This was an in vitro study. MATERIALS AND METHODS: Neem (A. indica) leaf nanoparticles were prepared and reinforced with PEEK powder at 10%, 20%, and 30% weight ratios by injection molding. Sixty specimens underwent the microhardness and CA testing using a digital microhardness tester, and CA goniometer, respectively, and later nanoindentation test to analyze the nanohardness and SR. STATISTICAL ANALYSIS USED: A one-way ANOVA test with a 95% confidence interval for MSH and NSH, SR, and CA was performed on the samples. A post hoc Bonferroni test was conducted (α = 0.05) to compare the groups. RESULTS: There was a significant increase in nanohardness (P = 0.000) with zero difference in microhardness (P = 0.514). The addition of 10 wt%, 20 wt%, and 30 wt% nanoparticles increased the SR value of the pure PEEK from 273.19 nm to 284.10 (3.99%), 296.91 (8.68%), and 287.54 (5.24%), respectively. In the analysis of the CA, CA 20% shows the lowest angle (63.69) with the highest for control specimens (82.39). There is an increase in the PEEK composite SR with a decrease in CA. CONCLUSIONS: The addition of plant-derived nanoparticles into the PEEK matrix has a significant impact on the hardness and hydrophobicity enhancing cell growth and osteoblastic differentiation during osseointegration of dental implants.


Assuntos
Benzofenonas , Cetonas , Nanopartículas , Polietilenoglicóis , Polímeros , Propriedades de Superfície , Molhabilidade , Polietilenoglicóis/química , Cetonas/química , Nanopartículas/química , Dureza , Técnicas In Vitro , Implantes Dentários , Teste de Materiais/métodos , Folhas de Planta/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...