Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.394
Filtrar
1.
Medicine (Baltimore) ; 103(29): e39008, 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39029080

RESUMO

BACKGROUND: The pain sensation in a transperineal prostate biopsy was obvious. This study explored the clinical value of ultrasound-guided full-needle path anesthesia in transperineal prostate biopsy. METHODS: Two hundred patients who underwent ultrasound-guided transperineal prostate biopsy at our department were randomly divided into 2 groups. The control group received routine local infiltration anesthesia, and the experimental group received ultrasound-guided full-needle path anesthesia. Immediately after biopsy, visual analog scoring was used to evaluate pain during the biopsy process. Seven days postbiopsy, telephone follow-up revealed symptoms, such as hematuria and discomfort during urination. The measured data were expressed as x ±â€…s. The 2 groups were compared using the t test, and the differences were statistically significant (P < .05). RESULTS: There were no significant differences in age, prostate-specific antigen (PSA) level, or prostate volume between the 2 groups, and all patients underwent prostate biopsy. The pain score of visual analog score was (2.55 ±â€…0.88), urination discomfort was (1.86 ±â€…0.67) days and hematuria time was (2.87 ±â€…0.91) days in the experimental group after biopsy. In the control group, the pain score of visual analog scale was (4.32 ±â€…0.94), the urination discomfort was (2.3 ±â€…0.77) days, and the hematuria time was (2.85 ±â€…0.83) days. Pain scores and urination discomfort were compared between the 2 groups (P < .01). Pain and urination discomfort associated with prostate biopsy in the experimental group were significantly lower than those in the control group. CONCLUSION: Ultrasound-guided full needle path anesthesia can alleviate pain sensation in patients undergoing transperineal prostate biopsy and has high clinical value.


Assuntos
Medição da Dor , Próstata , Ultrassonografia de Intervenção , Humanos , Masculino , Próstata/patologia , Próstata/diagnóstico por imagem , Pessoa de Meia-Idade , Ultrassonografia de Intervenção/métodos , Idoso , Biópsia Guiada por Imagem/métodos , Biópsia Guiada por Imagem/efeitos adversos , Períneo , Anestesia Local/métodos , Neoplasias da Próstata/patologia , Biópsia por Agulha/métodos , Biópsia por Agulha/efeitos adversos , Dor/etiologia
2.
Folia Med (Plovdiv) ; 66(2): 179-187, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38690812

RESUMO

INTRODUCTION: Evaluation of patients with peripheral lung lesions and lesions of the chest wall and mediastinum is challenging. The nature of the lesion identified by imaging studies can be determined by histological evaluation of biopsies. An important place in this direction is the ever-increasing popularity among thoracic surgeons of the transthoracic biopsy with a cutting needle under ultrasound control (US-TTCNB).


Assuntos
Mediastino , Parede Torácica , Humanos , Biópsia por Agulha/efeitos adversos , Biópsia por Agulha/métodos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Pulmão/patologia , Pulmão/diagnóstico por imagem , Pneumopatias/patologia , Pneumopatias/diagnóstico por imagem , Pneumopatias/etiologia , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Mediastino/patologia , Mediastino/diagnóstico por imagem , Parede Torácica/diagnóstico por imagem , Parede Torácica/patologia
3.
Clin Nephrol ; 102(2): 73-78, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38699984

RESUMO

Controversy exists as to the optimal observational time (OT) after outpatient percutaneous kidney biopsy. Further, there is some uncertainty about the benefit of smaller (18-gauge) vs. larger (16-gauge) biopsy needles. At our institution, we have been lowering the OT after outpatient kidney biopsies. Initially in 2015, we were monitoring for 6 hours and gradually began to decrease the OT over time. From 2020, we have adopted an OT of less than 4 hours. During this time period (in 2018), we also began using a smaller gauge needle (18 gauge). We reviewed all outpatient kidney biopsies performed by the nephrology division at our institution since 2015. There were 137 biopsies reviewed. 63 had OT of 4 - 6 hours, and 74 had OT < 4 hours. There was a total of 4 significant complications (2.9%). Two complications, symptomatic retroperitoneal bleeds, were detected in less than 3 hours. The other 2 complications were seen at 9 hours (clot retention) and 72 hours (retroperitoneal bleed after anticoagulation restarted). 63% of the biopsies were done using 18-gauge needles with 1 complication in this group vs. 3 in the 16-gauge group. All cases had adequate tissue for interpretation based on the ability to make a kidney diagnosis. The number of glomeruli obtained in the 18-gauge group was 29 ± 13 glomeruli, and in the 16-gauge group was 25 ± 10, which did not differ between groups. In summary, in an outpatient population, all significant post-biopsy complications were evident either within the first 3 hours or after 9 hours, and this suggests the feasibility of using shorter than standard OT in outpatient kidney biopsies. Furthermore, an 18-gauge needle may lower the risk of complications and obtain adequate tissue.


Assuntos
Rim , Agulhas , Humanos , Rim/patologia , Feminino , Masculino , Fatores de Tempo , Pessoa de Meia-Idade , Estudos Retrospectivos , Biópsia por Agulha/instrumentação , Biópsia por Agulha/métodos , Biópsia por Agulha/efeitos adversos , Adulto , Idoso , Desenho de Equipamento , Assistência Ambulatorial , Nefropatias/patologia
4.
Eur Rev Med Pharmacol Sci ; 28(9): 3439-3446, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38766800

RESUMO

OBJECTIVE: Due to infectious complications of transrectal prostate biopsy (TRBx), the transperineal prostate biopsy (TPBx) technique is gaining popularity and is the first-line method in many institutions. We share our experience of the first 100 patients with TPBx, performed using the coaxial needle technique under local anesthesia. PATIENTS AND METHODS: We retrospectively reviewed the records of the first 100 patients who had undergone TPBx between December 2022 and September 2023. Complication rates, cancer detection rates, patient tolerance, and pain response to the TPBx under local anesthesia at different steps of the procedure were collected. RESULTS: The mean age, total prostate-specific antigen (PSA), prostate volume, and PSA density were 64.5±7.5 years, 8.82±12 ng/mL, 58.4±26.4 mL, and 0.17±0.18 ng/mL2. Prostate cancer (PCa) was detected at histopathological evaluation in 51 patients. The mean positive core number and percentage of cancer involvement per core in patients who have PCa were 5.4±3.2 and 68.5±29.1, respectively. The mean pain score during the entire procedure was 2.85±1.48. When the steps are evaluated separately, the mean pain score during the probe placement step, local anesthetic, and sampling steps were 3.35±1.65, 2.54±1.45, and 0.9±0.82, respectively. CONCLUSIONS: Transperineal prostate biopsy with coaxial needle technique under local anesthesia is a well-tolerated procedure with feasible complication rates and patient discomfort.


Assuntos
Anestesia Local , Próstata , Neoplasias da Próstata , Humanos , Masculino , Pessoa de Meia-Idade , Anestesia Local/efeitos adversos , Anestesia Local/métodos , Estudos Retrospectivos , Idoso , Neoplasias da Próstata/patologia , Próstata/patologia , Períneo , Antígeno Prostático Específico/sangue , Biópsia por Agulha/efeitos adversos , Biópsia por Agulha/métodos
5.
Radiologia (Engl Ed) ; 66 Suppl 1: S40-S46, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38642960

RESUMO

OBJETIVE: To assess the ability of an artificial intelligence software to detect pneumothorax in chest radiographs done after percutaneous transthoracic biopsy. MATERIAL AND METHODS: We included retrospectively in our study adult patients who underwent CT-guided percutaneous transthoracic biopsies from lung, pleural or mediastinal lesions from June 2019 to June 2020, and who had a follow-up chest radiograph after the procedure. These chest radiographs were read to search the presence of pneumothorax independently by an expert thoracic radiologist and a radiodiagnosis resident, whose unified lecture was defined as the gold standard, and the result of each radiograph after interpretation by the artificial intelligence software was documented for posterior comparison with the gold standard. RESULTS: A total of 284 chest radiographs were included in the study and the incidence of pneumothorax was 14.4%. There were no discrepancies between the two readers' interpretation of any of the postbiopsy chest radiographs. The artificial intelligence software was able to detect 41/41 of the present pneumothorax, implying a sensitivity of 100% and a negative predictive value of 100%, with a specificity of 79.4% and a positive predictive value of 45%. The accuracy was 82.4%, indicating that there is a high probability that an individual will be adequately classified by the software. It has also been documented that the presence of Port-a-cath is the cause of 8 of the 50 of false positives by the software. CONCLUSIONS: The software has detected 100% of cases of pneumothorax in the postbiopsy chest radiographs. A potential use of this software could be as a prioritisation tool, allowing radiologists not to read immediately (or even not to read) chest radiographs classified as non-pathological by the software, with the confidence that there are no pathological cases.


Assuntos
Pneumotórax , Adulto , Humanos , Pneumotórax/diagnóstico por imagem , Pneumotórax/etiologia , Inteligência Artificial , Estudos Retrospectivos , Biópsia por Agulha/efeitos adversos , Tomografia Computadorizada por Raios X
6.
Zhonghua Yi Xue Za Zhi ; 104(16): 1403-1409, 2024 Apr 23.
Artigo em Chinês | MEDLINE | ID: mdl-38644291

RESUMO

Objective: To investigate the safety and accuracy of CT-guided intracranial puncture biopsy and the possible influencing factors of postoperative bleeding complications. Methods: A case series study. A retrospective analysis was conducted on 101 patients who underwent CT-guided intracranial puncture biopsy at the First Affiliated Hospital of Zhengzhou University from January 2017 to December 2021. The basic data of patients and the safety and accuracy of CT-guided intracranial puncture biopsy were analyzed statistically. Univariate and multivariate logistic regression analysis were used to screen the influencing factors of bleeding complications in CT-guided intracranial puncture biopsy, and the bleeding complications in glioma subgroup were analyzed. Results: Among the 101 patients, 53 were males and 48 were females, aged (53.7±17.2) years. The average diameter of intracranial lesions was (3.5±1.4) cm, while the vertical distance from the lesion to the meninges was (2.4±1.7) cm. The needle's intracranial depth reached (3.2±1.8) cm, with adjustments averaging (3±1) occurrences and an average procedural duration of (40.2±12.9) minutes. Pathological diagnoses included glioma (36 cases), gliosis (3 cases), lymphoma (32 cases), metastatic tumors (7 cases), inflammatory lesions (13 cases), and 10 indeterminate cases. The positive rate of puncture pathology was 90.1% (91/101), and the diagnostic coincidence rate was 94.0% (78/83). The incidence of bleeding complications in CT-guided intracranial puncture biopsy was 26.7% (27/101), of which 23 cases had small intratoma or needle path bleeding, 4 cases had massive bleeding, and 2 cases died. The patients were divided into bleeding group (n=27) and no bleeding group (n=74), according to the presence or absence of bleeding. The results of univariate logistic regression analysis showed that thrombin time≥15 s and the number of needle adjustment were the factors affecting the occurrence of bleeding complications (both P<0.05), and the results of multivariate logistic regression showed that thrombin time≥15 s was the related factor for bleeding. Patients with thrombin time≥15 s had a 3.045 times higher risk of bleeding than those with thrombin time<15 s (OR=3.045,95%CI:1.189-7.799,P=0.020). Among the 101 patients, 36 cases of midbrain glioma were divided into low-grade glioma group (n=11) and high-grade glioma group (n=25) according to the pathological grade. Subgroup analysis showed that the risk of bleeding for high-grade gliomas was 9.231 times higher than that for low-grade gliomas (OR=9.231,95%CI:1.023-83.331,P=0.031). Conclusions: CT-guided intracranial puncture biopsy is safe and feasible with high accuracy. Complication rates are associated with thrombin time≥15 s, especially high-grade glioma, which increases the risk of postoperative bleeding.


Assuntos
Neoplasias Encefálicas , Biópsia Guiada por Imagem , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Glioma/patologia , Adulto , Idoso , Encéfalo/patologia , Biópsia por Agulha/efeitos adversos , Biópsia por Agulha/métodos
7.
J Vasc Interv Radiol ; 35(6): 859-864, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38447771

RESUMO

PURPOSE: To compare the effectiveness of percutaneous lung biopsy using a patient-mounted needle-driving robotic system with that using a manual insertion of needles under computed tomography (CT) fluoroscopy guidance. MATERIALS AND METHODS: In this institutional review board approved study, the cohort consisted of a series of patients who underwent lung biopsies following the intention-to-treat protocol from September 2022 to September 2023 using robot (n = 15) or manual insertion under single-rotation CT fluoroscopy (n = 66). Patient and procedure characteristics were recorded as well as outcomes. RESULTS: Although age, body mass index, and skin-to-target distance were not statistically different, target size varied (median, 8 mm [interquartile range, 6.5-9.5 mm] for robot vs 12 mm [8-18 mm] for single-rotation CT fluoroscopy; P = .001). No statistical differences were observed in technical success (86.7% [13/15] vs 89.4% [59/66], P = .673), Grade 3 adverse event (AE) (6.7% [1/15] vs 12.1% [8/66], P = .298), procedural time (28 minutes [22-32 minutes] vs 19 minutes [14.3-30.5 minutes], P = .086), and patient radiation dose (3.9 mSv [3.2-5.6 mSv] vs 4.6 mSv [3.3-7.5 mSv], P = .398). In robot-assisted cases, the median angle out of gantry plane was 10° (6.5°-16°), although it was null (0°-5°) for single-rotation CT fluoroscopy (P = .001). CONCLUSIONS: Robot-assisted and single-rotation CT fluoroscopy-guided percutaneous lung biopsies were similar in terms of technical success, diagnostic yield, procedural time, AEs, and radiation dose, although robot allowed for out-of-gantry plane navigation along the needle axis.


Assuntos
Biópsia Guiada por Imagem , Pulmão , Radiografia Intervencionista , Procedimentos Cirúrgicos Robóticos , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Fluoroscopia , Pessoa de Meia-Idade , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/instrumentação , Idoso , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/instrumentação , Pulmão/diagnóstico por imagem , Pulmão/patologia , Biópsia por Agulha/efeitos adversos , Biópsia por Agulha/instrumentação , Valor Preditivo dos Testes , Agulhas , Desenho de Equipamento , Fatores de Tempo
8.
Minim Invasive Ther Allied Technol ; 33(3): 171-175, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38315057

RESUMO

INTRODUCTION: The purpose is to clarify the safety and clinical contribution of computed tomography (CT)-guided percutaneous needle-biopsy for patients with cervical spine lesion. MATERIAL AND METHODS: Between June 2015 and August 2022, CT-guided percutaneous needle biopsies were performed for 15 cervical spine lesions of 15 patients (8 male, 7 female; 2-81 years old). The technical success, clinical contribution, and safety were evaluated. Technical success was defined as the completion of the biopsy procedure. Clinical contribution was defined as any contribution to the therapeutic strategy. Safety was assessed by the Common Terminology Criteria for Adverse Events, version 5.0. RESULTS: The technical success rate was 100%. In all 15 patients, nontarget organs (e.g., major vessels, spinal cord) could be avoided. The post-biopsy histological diagnoses were myeloma (n = 2), metastatic adenocarcinoma (n = 2), chordoma (n = 2), Langerhans cell histiocytosis (n = 3), and one case each of malignant lymphoma, schwannoma, pyogenic spondylitis, non-pyogenic spondylitis, degenerative change, and non-pathological fracture. All of these diagnoses contributed to the therapeutic strategy decisions. One case of grade 2 pain was observed, but no complications with grade 3 or more were observed during or after the biopsies. CONCLUSION: CT-guided percutaneous needle biopsies for cervical spine lesions were safe and clinically beneficial.


Assuntos
Vértebras Cervicais , Biópsia Guiada por Imagem , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Biópsia Guiada por Imagem/métodos , Biópsia Guiada por Imagem/efeitos adversos , Idoso de 80 Anos ou mais , Adulto , Adolescente , Adulto Jovem , Criança , Pré-Escolar , Biópsia por Agulha/efeitos adversos , Biópsia por Agulha/métodos , Estudos Retrospectivos , Doenças da Coluna Vertebral/patologia
9.
BMC Pulm Med ; 24(1): 33, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38218792

RESUMO

OBJECTIVE: This study aimed to assess the incidence and clinical significance of pneumothorax (PTX) and pulmonary hemorrhage (PH) after percutaneous transthoracic lung biopsy (PTLB) guided by C-arm cone-beam computed tomography (CBCT). Furthermore, this study aimed to examine the relationships between PTX and PH with demographics, clinical characteristics, imaging, and PTLB parameters. METHODS: A retrospective analysis was conducted on 192 patients who underwent PTLB at our hospital between January 2019 and October 2022. Incidences of PTX and PH were recorded. PTX was considered clinically significant if treated with chest tube insertion (CTI), and PH if treated with bronchoscopes or endovascular treatments. The various factors on PTX and PH were analyzed using the Chi-squared test and Student t-test. Logistic regression analyses were then used to determine these factors on the correlation to develop PTX and PH. RESULTS: PTX occurred in 67/192 cases (34.9%); CTI was required in 5/67 (7.5%). PH occurred in 63/192 cases (32.8%) and none of these cases required bronchoscopes or endovascular treatments. Lesion diameter (ORPTX = 0.822; ORPH = 0.785), presence of pulmonary emphysema (ORPH = 2.148), the number of samples (ORPH = 1.834), the use of gelfoam (ORPTX = 0.474; ORPH = 0.341) and ablation (ORPTX = 2.351; ORPH = 3.443) showed statistically significant correlation to PTX and PH. CONCLUSIONS: CBCT-guided PTLB is a safe and effective method for performing lung biopsies. The use of gelfoam has been shown to reduce the occurrence of PTX and PH. However, caution should be exercised when combining radiofrequency ablation with PTLB, as it may increase the risk of PTX and PH.


Assuntos
Pneumopatias , Pneumotórax , Humanos , Pneumotórax/epidemiologia , Pneumotórax/etiologia , Pneumotórax/patologia , Incidência , Estudos Retrospectivos , Relevância Clínica , Pulmão/diagnóstico por imagem , Pulmão/patologia , Pneumopatias/diagnóstico por imagem , Pneumopatias/epidemiologia , Pneumopatias/complicações , Tomografia Computadorizada de Feixe Cônico , Hemorragia/epidemiologia , Hemorragia/etiologia , Biópsia por Agulha/efeitos adversos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Fatores de Risco
10.
Cardiovasc Intervent Radiol ; 47(5): 604-612, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38263525

RESUMO

PURPOSE: To determine whether instillation of normal saline solution for sealing the needle track reduces incidence of pneumothorax and chest tube placement after computed tomography-guided percutaneous lung biopsy. MATERIALS AND METHODS: A total of 242 computed tomography-guided percutaneous lung biopsies performed at a single institution were retrospectively reviewed, including 93 biopsies in which the needle track was sealed by instillation of 3-5 ml of normal saline solution during needle withdrawal (water seal group) and 149 biopsies without sealing (control group). Patient and lesion characteristics, procedure-specific variables, pneumothorax and chest tube placement rates were recorded. RESULTS: Baseline characteristics were comparable in both groups. There was a statistically significant decrease in the pneumothorax rate (19.4% [18/93] vs. 40.9% [61/149]; p < 0.001) and a numerically lower chest tube placement rate without significant reduction (4.3% [4/93] vs. 10.7% [16/149]; p = 0.126) with using normal saline instillation for sealing the needle track versus not using sealant material. Using a multiple logistic regression analysis, using normal saline instillation to seal the needle track, having a senior radiologist as operator of the procedure and putting patients in prone position were significantly associated with a decreased risk of pneumothorax. The presence of emphysema along the needle track was significantly associated with an increased risk of pneumothorax. No complication was observed due to normal saline injection. CONCLUSION: Normal saline solution instillation for sealing the needle track after computed tomography-guided percutaneous lung biopsy is a simple, low-cost and safe technique resulted in significantly decreased pneumothorax occurrence and a numerically lower chest tube placement rate, and might help to reduce both hospitalization risks and costs for the healthcare system. Level of evidence 3 Non-controlled retrospective cohort study.


Assuntos
Biópsia Guiada por Imagem , Pulmão , Pneumotórax , Radiografia Intervencionista , Solução Salina , Tomografia Computadorizada por Raios X , Humanos , Pneumotórax/etiologia , Pneumotórax/prevenção & controle , Pneumotórax/epidemiologia , Feminino , Masculino , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Pessoa de Meia-Idade , Solução Salina/administração & dosagem , Incidência , Idoso , Biópsia Guiada por Imagem/métodos , Biópsia Guiada por Imagem/efeitos adversos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Radiografia Intervencionista/métodos , Biópsia por Agulha/efeitos adversos , Biópsia por Agulha/métodos , Tubos Torácicos , Adulto
12.
Forensic Sci Med Pathol ; 20(1): 199-204, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37160632

RESUMO

Computed tomography (CT)-guided percutaneous needle biopsy of the lung is a well-recognized and relatively safe diagnostic procedure for suspicious lung masses. Systemic air embolism (SAE) is a rare complication of transthoracic percutaneous lung biopsies. Herein, we present a case of an 81-year-old man who underwent CT-guided percutaneous needle biopsy of a suspicious nodule in the lower lobe of the right lung. Shortly after the procedure, the patient coughed up blood which prompted repeat CT imaging. He was found to have a massive cardiac air embolism. The patient became unresponsive and, despite resuscitation efforts, was pronounced dead. The pathophysiology, risk factors, clinical features, radiological evidence, and autopsy findings associated with SAE are discussed, which may, in light of the current literature, assist with the dilemma between assessing procedural complications and medical liability. Given the instances of SAE in the setting of long operative procedures despite careful technical execution, providing accurate and in-depth information, including procedure-related risks, even the rarest but potentially fatal ones, is recommended for informed consent to reduce medicolegal litigation issues.


Assuntos
Embolia Aérea , Imperícia , Masculino , Humanos , Idoso de 80 Anos ou mais , Embolia Aérea/diagnóstico por imagem , Embolia Aérea/etiologia , Embolia Aérea/patologia , Pulmão/diagnóstico por imagem , Pulmão/patologia , Biópsia por Agulha/efeitos adversos , Biópsia por Agulha/métodos , Tomografia Computadorizada por Raios X/efeitos adversos , Biópsia Guiada por Imagem/efeitos adversos
13.
Forensic Sci Med Pathol ; 20(1): 295-296, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37357244

RESUMO

To differentiate between medical malpractice and expected, but rare, medical complication in a medicolegal autopsy context is often difficult. Such an assessment requires knowledge about the clinical practice associated with the procedure at hand, and that findings of the autopsy, including medical relevant information such as patient chart, radiological imaging, and statements from witnesses about the medical procedure itself, provides evidence that substantiate either conclusion. In a case report published in the journal such an assessment is discussed by presenting findings and circumstances surrounding the death of a patient during a percutaneous needle lung biopsy procedure. The authors conclude that the death was not due to medical malpractice. However, in this commentary it is highlighted that the reasoning behind the conclusion needs to be further substantiated.


Assuntos
Embolia Aérea , Imperícia , Humanos , Embolia Aérea/diagnóstico por imagem , Embolia Aérea/etiologia , Embolia Aérea/patologia , Tomografia Computadorizada por Raios X/efeitos adversos , Biópsia por Agulha/efeitos adversos , Biópsia por Agulha/métodos , Pulmão/diagnóstico por imagem , Pulmão/patologia
14.
AJR Am J Roentgenol ; 222(2): e2329938, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37910039

RESUMO

BACKGROUND. Changes in lung parenchyma elasticity in usual interstitial pneumonia (UIP) may increase the risk for complications after percutaneous transthoracic needle biopsy (PTNB) of the lung. OBJECTIVE. The purpose of this article was to investigate the association of UIP findings on CT with complications after PTNB, including pneumothorax, pneumothorax requiring chest tube insertion, and hemoptysis. METHODS. This retrospective single-center study included 4187 patients (mean age, 63.8 ± 11.9 [SD] years; 2513 men, 1674 women) who underwent PTNB between January 2010 and December 2015. Patients were categorized into a UIP group and non-UIP group by review of preprocedural CT. In the UIP group, procedural CT images were reviewed to assess for traversal of UIP findings by needle. Multivariable logistic regression analyses were performed to identify associations between the UIP group and needle traversal with postbiopsy complications, controlling for a range of patient, lesion, and procedural characteristics. RESULTS. The UIP and non-UIP groups included 148 and 4039 patients, respectively; in the UIP group, traversal of UIP findings by needle was observed in 53 patients and not observed in 95 patients. The UIP group, in comparison with the non-UIP group, had a higher frequency of pneumothorax (35.1% vs 17.9%, p < .001) and pneumothorax requiring chest tube placement (6.1% vs 1.5%, p = .001) and lower frequency of hemoptysis (2.0% vs 6.1%, p = .03). In multivariable analyses, the UIP group with traversal of UIP findings by needle, relative to the non-UIP group, showed independent associations with pneumothorax (OR, 5.25; 95% CI, 2.94-9.37; p < .001) and pneumothorax requiring chest tube placement (OR, 9.55; 95% CI, 3.74-24.38; p < .001). The UIP group without traversal of UIP findings by needle, relative to the non-UIP group, was not independently associated with pneumothorax (OR, 1.18; 95% CI, 0.71-1.97; p = .51) or pneumothorax requiring chest tube placement (OR, 1.08; 95% CI, 0.25-4.72; p = .92). The UIP group, with or without traversal of UIP findings by needle, was not independently associated with hemoptysis. No patient experienced air embolism or procedure-related death. CONCLUSION. Needle traversal of UIP findings is a risk factor for pneumothorax and pneumothorax requiring chest tube placement after PTNB. CLINICAL IMPACT. When performing PTNB in patients with UIP, radiologists should plan a needle trajectory that does not traverse UIP findings, when possible.


Assuntos
Fibrose Pulmonar Idiopática , Neoplasias Pulmonares , Pneumotórax , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Pneumotórax/etiologia , Hemoptise/etiologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Radiografia Intervencionista/métodos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Biópsia por Agulha/efeitos adversos , Biópsia por Agulha/métodos , Neoplasias Pulmonares/patologia , Fibrose Pulmonar Idiopática/patologia , Fatores de Risco
15.
Cardiovasc Intervent Radiol ; 47(1): 87-91, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38129337

RESUMO

BACKGROUND: Percutaneous liver biopsy has proven to be a valuable tool in the workup of pediatric acute liver failure and the management of post-transplant rejection. However, consensus regarding pre-procedure laboratory values and post-procedure monitoring is lacking. OBJECTIVE: To characterize the incidence of complications, procedural time, and specimen adequacy for percutaneous liver biopsy in the pediatric patient. METHODS: Retrospective review of percutaneous liver biopsies at a single institution was performed for a 5-year span. Procedural notes and anesthesia records were sampled for patient weight and procedural factors across a continuous 6-month period, as well as for the subgroup of patients under 24 months of age. A representative continuous subset of pathology reports comprising 376 patients were reviewed for estimation of specimen adequacy. RESULTS: Eight hundred and sixty-seven ultrasound-guided percutaneous liver biopsies were performed in a 5-year period, 450 of which were in the post-transplant setting with about a 3:1 ratio of split: whole liver transplant. Patient ages ranged from 1 month to 21 years old, with weight ranging from 2.7 to 125 kg. Of the 376 pathology reports available, none were found to be inadequate for evaluation. Two major complications occurred, both of which were biliary leaks in the setting split-liver transplant. There were no incidences of post-procedure hemorrhage. Of the sample reviewed, mean "skin-to-skin" procedure time was under 8.5 min (median of 7 min). Solely among transplant patients, biopsies for split livers averaged 9.2 min, biopsies for whole livers averaged 6.2 min (two-tailed independent t test, p = 0.0426). CONCLUSION: Ultrasound guided percutaneous liver biopsy is fast, useful, and safe in pediatric patients on an outpatient basis with same day discharge. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Biópsia Guiada por Imagem , Fígado , Criança , Humanos , Lactente , Fígado/diagnóstico por imagem , Fígado/patologia , Ultrassonografia , Biópsia por Agulha/efeitos adversos , Biópsia por Agulha/métodos , Estudos Retrospectivos , Ultrassonografia de Intervenção
16.
Clin Imaging ; 104: 110017, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37979400

RESUMO

PURPOSE: Bleeding is a well-known risk of percutaneous breast biopsy, frequently controlled with manual pressure. However, significant bleeding complications may require further evaluation or intervention. Our objectives were to assess the rate, type, and periprocedural management of significant bleeding following percutaneous breast biopsy and to evaluate the success of any interventions. METHODS: We retrospectively reviewed percutaneous breast biopsies at our institution over a 10-year period with documented post-biopsy bleeding complications in radiology reports. Patients were included if bleeding required intervention (interventional radiology [IR], surgery, or other), imaging follow-up, or clinical evaluation for symptoms. Additional data included patient demographics, anticoagulation, history of bleeding diathesis, biopsy details, bleeding symptoms, histopathology, and intervention details, if applicable. RESULTS: Of 5820 unique patients who underwent percutaneous biopsy, 66 patients (66/5820; 1.1%) comprising 71 biopsy cases met inclusion for clinically significant bleeding with 5/71(7.0%) requiring surgery, 9/71(12.7%) requiring IR intervention, and 57/71(80.3%) requiring lower-acuity intervention including prolonged observation (5/57;7.0%), overnight admission (4/57;5.6%), aspiration (4/57;5.6%), lidocaine and suture (2/57;2.8%), primary care visit (7/57;10.0%), blood transfusion (1/57;1.4%), emergency room visit (6/57;8.5%), surgery consult (8/57;11.3%), IR consult (2/57;2.8%), and follow-up imaging (22/57;31.0%). Most patients requiring intervention by surgery or IR had acute signs of bleeding immediately after biopsy while most patients with delayed signs of bleeding required lower-acuity interventions. CONCLUSION: Clinically significant bleeding is extremely rare after percutaneous breast biopsy and is most often managed non-surgically. Developing an institutional algorithm for management of bleeding complications that consults IR before surgery may help decrease the number of patients managed surgically.


Assuntos
Transtornos da Coagulação Sanguínea , Hemorragia , Humanos , Estudos Retrospectivos , Biópsia por Agulha/efeitos adversos , Biópsia/efeitos adversos , Hemorragia/epidemiologia , Hemorragia/etiologia , Hemorragia/terapia , Transtornos da Coagulação Sanguínea/complicações
17.
BMC Pulm Med ; 23(1): 403, 2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37875852

RESUMO

As a result of advances in the treatment of lung cancer, the life expectancy of lung cancer patients has improved significantly, but it remains the leading cause of cancer death worldwide. For decades, most of the initial tumor biopsies have been obtained by bronchoscopy or computed tomography (CT)-guided transthoracic lung biopsy without concerning reports of cancer seeding following the latter. In this case report we discuss the patient history of a 56-year old women with low-differentiated squamous cell lung cancer who developed tumor seeding following a CT-guided transthoracic biopsy 11 months after the intervention. This is put into context reviewing former and current literature.


Assuntos
Neoplasias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Biópsia por Agulha/efeitos adversos , Biópsia por Agulha/métodos , Neoplasias Pulmonares/patologia , Pulmão/diagnóstico por imagem , Pulmão/patologia , Tórax/patologia , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Inoculação de Neoplasia , Tomografia Computadorizada por Raios X/métodos
18.
Asian Pac J Cancer Prev ; 24(9): 3059-3064, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37774057

RESUMO

INTRODUCTION: CT-guided tru-cut biopsy, which is less invasive and cost-effective, is an important diagnostic tool with high accuracy in lesions located peripherally in the lung. In this article, CT-guided tru-cut biopsy experiences of thoracic surgeons are shared. MATERIALS AND METHODS: CT-guided tru-cut biopsy was performed on 200 patients with suspected lung lesions in the thoracic surgery clinic. Diagnostic rates of biopsies, complications, factors affecting the development of complications, and complication management were examined. RESULTS: The diagnostic rate of the biopsies was 88%. Pneumothorax developed in 19.5% and hemothorax in 1% after the procedure. There was a significant relationship between mass dimensions and total complication rates (p=0.017). The relationship between the distance among the pleura and the mass and the development of complications was significant (p<0.001). The relationship between the number of biopsies and the development of pneumothorax was significant (p=0.011). The relationship between the size of the mass and the development of pneumothorax was significant (p=0.011). In univariate binary logistic regression analysis, a significant correlation was found between the size of the mass and the development of total complications (odds ratio (OR)=0.356 (95% CI: (0.146-0.868), (p=0.023)). DISCUSSION: In the diagnosis of lung lesions, CT-guided tru-cut biopsy is an effective diagnostic tool with high diagnostic power, with its less invasiveness, and lower cost. The increase in the lung parenchyma distance passed with the biopsy needle increased the likelihood of complications most significantly. The size of the mass and the number of biopsies also had significant effects on the development of complications.


Assuntos
Neoplasias Pulmonares , Pneumotórax , Humanos , Pneumotórax/etiologia , Pneumotórax/patologia , Biópsia Guiada por Imagem/efeitos adversos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Biópsia por Agulha/efeitos adversos , Biópsia por Agulha/métodos , Neoplasias Pulmonares/patologia , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos
19.
In Vivo ; 37(5): 2237-2243, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37652495

RESUMO

BACKGROUND/AIM: This is a retrospective evaluation of whether percutaneous direct puncture biopsy of lung lesions contacting to the pleura is justified. PATIENTS AND METHODS: Between August 2016 and July 2021, 163 consecutive patients (100 males, 63 females with a median age of 73 years) who had malignant lung tumors measuring 0.6-12.4 cm (median, 2.9 cm) that contacted to the pleura and underwent percutaneous lung biopsy under computed tomography fluoroscopic guidance using an 18-gauge end-cut needle were examined. The trajectory was direct puncture in 80 patients (49.1%, 80/163), and trans-lung in 83 patients (50.9%, 83/163). Diagnostic yield and major adverse event rates of direct and trans-lung puncture biopsies were compared. RESULTS: No difference was found in diagnostic yield between direct puncture and trans-lung biopsies (93.8% vs. 98.8%, p=0.11). Major adverse events were major pneumothorax (n=13/163, 8.0%), pleural dissemination (n=18/163, 11.0%), and hemothorax requiring arterial embolization (n=1/163, 1.0%). Direct puncture caused major pneumothorax significantly less than trans-lung puncture did (0%, 0/80 vs. 15.7%, 13/83, p<0.001). No significant difference was found between the two biopsy methods regarding the incidence of pleural dissemination (11.0%, 11/80 vs. 8.4%, 7/83, p=0.32). CONCLUSION: Direct puncture biopsy of malignant lung tumors contacting to the pleura is justified.


Assuntos
Neoplasias Pulmonares , Pneumotórax , Masculino , Feminino , Humanos , Idoso , Pleura , Pneumotórax/etiologia , Pneumotórax/epidemiologia , Pneumotórax/patologia , Estudos Retrospectivos , Neoplasias Pulmonares/complicações , Biópsia por Agulha/efeitos adversos , Pulmão/patologia
20.
Am J Nephrol ; 54(11-12): 528-535, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37579726

RESUMO

INTRODUCTION: Real-time ultrasound-guided percutaneous kidney biopsy is essential for diagnosis and treatment planning; nonetheless, the optimal puncture approach has yet to be established. In vivo, performing different approaches on the same patient at once is not possible. This study aimed to determine the impact of different approaches on the number of obtained glomeruli and their potential to cause arterial injury using pig kidneys, which are similar to humans. METHODS: A total of 120 pig kidneys (60 right-sided kidneys and 60 left-sided kidneys) for research were obtained from a slaughterhouse. The specimens were collected from the lower pole on the sagittal plane of the kidney using three different approaches on the same kidney: caudocranial approach, caudal to cranial; craniocaudal approach, cranial to caudal; and vertical approach, through the surface cortex. Five blinded pediatric nephrologists assessed the number of glomeruli and arterial injuries. RESULTS: Overall, 360 specimens were collected from the kidneys through biopsy using a 16-gauge needle (mean vertical kidney length, 11.2 ± 0.7 cm; mean depth, 3.47 ± 0.23 cm). No significant difference in the incidence of arterial injury was observed between the three approaches (caudocranial vs. craniocaudal vs. vertical approaches: 78% vs. 87% vs. 87%, p = 0.14). In contrast, the vertical approach retrieved significantly more glomeruli than the caudocranial and craniocaudal approaches (caudocranial approach: 7.5 ± 2.8, craniocaudal approach: 7.8 ± 2.7, and vertical approach: 8.9 ± 3.3, p < 0.001). CONCLUSIONS: Considering its efficacy and safety profile, the vertical approach may be preferred, as more glomeruli can be obtained without increasing the incidence of arterial injury. Although the results cannot be directly extrapolated to humans due to the differences between species, they still offer important insights into the characteristics of each approach.


Assuntos
Glomérulos Renais , Rim , Criança , Humanos , Animais , Suínos , Biópsia por Agulha/efeitos adversos , Biópsia por Agulha/métodos , Rim/diagnóstico por imagem , Rim/patologia , Glomérulos Renais/patologia , Biópsia Guiada por Imagem/métodos , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...