Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.433
Filtrar
1.
Respir Physiol Neurobiol ; 328: 104304, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39096947

RESUMO

INTRODUCTION: Dissolved-phase 129Xe MRI metrics suggest that gas diffusion may be more compromised at submaximal lung inflation compared to maximal inflation. We hypothesized that this diffusion deficit could be detected by comparing the carbon monoxide transfer coefficient (Kco) at submaximal lung inflation to that measured routinely at total lung capacity (TLC). METHODS: Asthma and COPD patients performed carbon monoxide diffusion tests, first at maximal lung inflation for routine Kco and alveolar volume VA and then, at a 30 % reduced inflation (redux; obtaining Kcoredux and VAredux). At both inflations mixing efficiency was determined as VA/TLC and VAredux/TLCredux to examine a potential effect on Kcoredux/Kco behavior. RESULTS: In normal subjects (n=36), median Kcoredux/Kco amounted to 130 [IQR:122-136]% as expected for normal Kco recruitment response. However, 60 % of asthma patients (49/83) and 80 % of COPD patients (44/55) showed reduced Kco recruitment at submaximal inflation (Kcoredux/Kco<122 %). In the asthma group, with otherwise normal routine Kco, Kcoredux/Kco was significantly correlated with RV/TLC ratio (r=-0.53;P<0.001), but not with VA/TLC. In COPD patients, all with abnormal routine Kco, abnormal Kcoredux/Kco response occurred in those patients with lower FEV1, higher RV/TLC and lower VA/TLC (P<0.01 for all). CONCLUSION: Sizeable portions of COPD and asthma patients showed a lack of normal Kco recruitment at submaximal lung inflation, related to high RV/TLC. In asthma, this was the case despite normal Kco at full lung inflation, suggesting that hyperinflation at lung volumes less than TLC affects the carbon monoxide diffusion rate constant by distorting pulmonary capillaries and alveolar-capillary membranes.


Assuntos
Asma , Pulmão , Doença Pulmonar Obstrutiva Crônica , Humanos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Masculino , Asma/fisiopatologia , Feminino , Pessoa de Meia-Idade , Idoso , Pulmão/fisiopatologia , Pulmão/diagnóstico por imagem , Adulto , Monóxido de Carbono/metabolismo , Capacidade Pulmonar Total/fisiologia , Imageamento por Ressonância Magnética , Difusão , Isótopos de Xenônio
2.
BMC Pulm Med ; 24(1): 358, 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39049038

RESUMO

PURPOSE: The present study aimed to investigate the clinical characteristics and lung function impairment in young people diagnosed with chronic obstructive pulmonary disease (COPD). PATIENTS AND METHODS: We retrospectively enrolled patients with COPD who underwent symptom assessment and comprehensive pulmonary function tests at the First Affiliated Hospital of Guangzhou Medical University between August 2017 and March 2022. The patients were categorized into two groups based on age: a young COPD group (aged 20-50 years) and an old COPD group (aged > 50 years). RESULTS: A total of 1282 patients with COPD were included in the study, with 76 young COPD patients and 1206 old COPD patients. Young COPD patients exhibited a higher likelihood of being asymptomatic, lower rates of smoking, and a lower smoking index compared to old COPD patients. Although young COPD patients had higher median post-bronchodilator forced expiratory volume in 1 s (post-BD FEV1) (1.4 vs.1.2 L, P = 0.019), diffusing capacity of the lung for carbon monoxide (DLCO) (7.2 vs. 4.6, P<0.001), and a lower median residual volume to total lung capacity ratio (RV/TLC) compared to their older counterparts, there were no differences observed in severity distribution by GOLD categories or the proportion of lung hyperinflation (RV/TLC%pred > 120%) between two groups. Surprisingly, the prevalence of reduced DLCO was found to be 71.1% in young COPD, although lower than in old COPD (85.2%). CONCLUSION: Young COPD showed fewer respiratory symptoms, yet displayed a similar severity distribution by GOLD categories. Furthermore, a majority of them demonstrated lung hyperinflation and reduced DLCO. These results underscore the importance of a comprehensive assessment of lung function in young COPD patients.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Testes de Função Respiratória , Humanos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Adulto , Idoso , Adulto Jovem , Pulmão/fisiopatologia , Volume Expiratório Forçado , Fatores Etários , China/epidemiologia , Índice de Gravidade de Doença , Capacidade Pulmonar Total , Fumar/epidemiologia , Capacidade de Difusão Pulmonar
3.
BMC Pulm Med ; 24(1): 345, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39014325

RESUMO

BACKGROUND: In advanced chronic obstructive pulmonary disease (COPD), hypercapnia may occur due to severe bronchial obstruction with lung hyperinflation. Non-invasive ventilation (NIV) provides the standard of care intended to achieve physiological PCO2 levels, thereby reducing overall mortality. The present study aimed to evaluate pulmonary function parameters derived from spirometry (forced vital capacity [FVC], forced expiratory volume in 1 s [FEV1]), body plethysmography (residual volume [RV], total lung capacity [TLC]), and lung diffusion capacity for carbon monoxide (single-breath method [DCO-SB], alveolar-volume corrected values [DCO-VA]) as predictors of chronic hypercapnia in patients with advanced COPD. METHODS: This monocentric, retrospective observational study included 423 COPD patients. Receiver operating characteristic (ROC) curve analysis and cross-validation were used to assess lung function parameters' diagnostic accuracy for predicting chronic hypercapnia, with the resulting performance expressed as area under the ROC curve (AUROC). We performed univariable and multivariable binary logistic regression analysis to determine if these parameters were independently associated with chronic hypercapnia, with probabilities reported as odds ratios [OR] with 95% confidence intervals [95%CI]. RESULTS: FVC% (AUROC 0.77 [95%CI 0.72-0.81], P < 0.01) and FEV1% (AURIC 0.75 [95%CI 0.70-0.79], P < 0.01) exhibited reasonable accuracy in the prediction of chronic hypercapnia, whereas lung diffusion capacity performed poorly (AUROC 0.64 [95%CI 0.58-0.71] for DCO-SB%, P < 0.01). FVC% (OR 0.95 [95%CI 0.93-0.97], P < 0.01) and FEV1% (OR 0.97 [95%CI 0.94-0.99], P = 0.029) were the only parameters associated independently with chronic hypercapnia in logistic regression analysis. FVC and FEV1 thresholds that best separated hypercapnic from normocapnic subjects reached 56% and 33% of predicted values. CONCLUSIONS: Routinely collected pulmonary function parameters, particularly FVC% and FEV1%, may predict chronic hypercapnia during COPD progression.


Assuntos
Hipercapnia , Doença Pulmonar Obstrutiva Crônica , Curva ROC , Espirometria , Humanos , Hipercapnia/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/complicações , Masculino , Feminino , Idoso , Estudos Retrospectivos , Pessoa de Meia-Idade , Volume Expiratório Forçado , Capacidade Vital , Pulmão/fisiopatologia , Modelos Logísticos , Capacidade Pulmonar Total , Testes de Função Respiratória
4.
BMC Pulm Med ; 24(1): 256, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38789978

RESUMO

BACK GROUND: Knowledge concerning pulmonary function in adult patients with onset of idiopathic scoliosis before age 10 is sparse. A long-term follow-up (FU, mean 26 years, > 12 years after treatment) of pulmonary function (PF) in patients treated with brace or surgery due to idiopathic scoliosis with onset before the age of 10 was earlier performed. To evaluate whether a more severe reduction in pulmonary function leads to more rapid deterioration within a four-year period, this study was performed. METHODS: Twenty patients with the most reduced pulmonary function and 19 out of those with normal PF found at the long-term FU were reexamined 4 years later to evaluate further changes in pulmonary function. Patients underwent spirometry and arterial blood gas analysis and answered pulmonary symptom questionnaires. RESULTS: 70% of the reduced pulmonary function group had undergone surgery vs. 26% of the normal group. The mean age (47 vs. 43 years) at this FU and curve size (37° vs. 35°) at the 26-year FU were similar. The decline in forced vital capacity (FVC) % of predicted was similar in both groups over the four-year period, from 67 to 65% in the reduced PF group vs. 96 to 94% in the normal PF group. The total lung capacity (TLC) % of predicted did not change over time in either group. No patient reported worsening dyspnea symptoms. Only one patient in the reduced PF group showed low arterial oxygen tension, 8.4 kPa, not signifying respiratory insufficiency. CONCLUSION: The age-related decline in FVC and TLC % of predicted did not differ between those with reduced and those with normal pulmonary function at the 26-year follow-up. Thus, these data do not infer increased rate of decline in the most deteriorated patients.


Assuntos
Pulmão , Escoliose , Espirometria , Humanos , Escoliose/fisiopatologia , Feminino , Masculino , Adulto , Capacidade Vital , Pessoa de Meia-Idade , Pulmão/fisiopatologia , Progressão da Doença , Seguimentos , Criança , Capacidade Pulmonar Total , Testes de Função Respiratória , Gasometria , Braquetes , Inquéritos e Questionários , Idade de Início
5.
Respir Res ; 25(1): 155, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38570835

RESUMO

BACKGROUND: Reference values for lung volumes are necessary to identify and diagnose restrictive lung diseases and hyperinflation, but the values have to be validated in the relevant population. Our aim was to investigate the Global Lung Function Initiative (GLI) reference equations in a representative healthy Austrian population and create population-derived reference equations if poor fit was observed. METHODS: We analysed spirometry and body plethysmography data from 5371 respiratory healthy subjects (6-80 years) from the Austrian LEAD Study. Fit with the GLI equations was examined using z-scores and distributions within the limits of normality. LEAD reference equations were then created using the LMS method and the generalized additive model of location shape and scale package according to GLI models. RESULTS: Good fit, defined as mean z-scores between + 0.5 and -0.5,was not observed for the GLI static lung volume equations, with mean z-scores > 0.5 for residual volume (RV), RV/TLC (total lung capacity) and TLC in both sexes, and for expiratory reserve volume (ERV) and inspiratory capacity in females. Distribution within the limits of normality were shifted to the upper limit except for ERV. Population-derived reference equations from the LEAD cohort showed superior fit for lung volumes and provided reproducible results. CONCLUSION: GLI lung volume reference equations demonstrated a poor fit for our cohort, especially in females. Therefore a new set of Austrian reference equations for static lung volumes was developed, that can be applied to both children and adults (6-80 years of age).


Assuntos
Pulmão , Masculino , Adulto , Criança , Feminino , Humanos , Áustria/epidemiologia , Valores de Referência , Medidas de Volume Pulmonar/métodos , Capacidade Pulmonar Total , Espirometria/métodos , Volume Expiratório Forçado , Capacidade Vital
6.
BMC Pulm Med ; 24(1): 127, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38475751

RESUMO

BACKGROUND: The 2017 ATS/ERS technical standard for measuring the single-breath diffusing capacity (DLCO) proposed the "rapid-gas-analyzer" (RGA) or, equivalently, "total-breath" (TB) method for the determination of total lung capacity (TLC). In this study, we compared DLCO and TLC values estimated using the TB and conventional method, and how estimated TLC using these two methods compared to that determined by body plethysmography. METHOD: A total of 95 people with COPD (GOLD grades 1-4) and 23 healthy subjects were studied using the EasyOne Pro (ndd Medical Technologies, Switzerland) and Master Screen Body (Vyaire Medical, Höchberg, Germany). RESULTS: On average the TB method resulted in higher values of DLCO (mean ± SD Δ = 0.469 ± 0.267; 95%CI: 0.420; 0.517 mmol*min-1*kPa-1) and TLC (Δ = 0.495 ± 0.371; 95%CI: 0.427; 0.562 L) compared with the conventional method. In healthy subjects the ratio between TB and conventional DLCO was close to one. TLC estimated using both methods was lower than that determined by plethysmography. The difference was smaller for the TB method (Δ = 1.064 ± 0.740; 95%CI: 0.929; 1.199 L) compared with the conventional method (Δ = 1.558 ± 0.940; 95%CI: 1.387; 1.739 L). TLC from body plethysmography could be estimated as a function of TB TLC and FEV1 Z-Score with an accuracy (normalized root mean square difference) of 9.1%. CONCLUSION: The total-breath method yielded higher values of DLCO and TLC than the conventional analysis, especially in subjects with COPD. TLC from the total-breath method can also be used to estimate plethysmographic TLC with better accuracy than the conventional method. The study is registered under clinicaltrial.gov NCT04531293.


Assuntos
Capacidade de Difusão Pulmonar , Doença Pulmonar Obstrutiva Crônica , Humanos , Alemanha , Testes de Função Respiratória , Capacidade Pulmonar Total
7.
Respir Care ; 69(3): 366-375, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38416659

RESUMO

BACKGROUND: Lung hyperinflation is a typical clinical feature of patients with COPD. Given the association between breathing at elevated lung volumes and the manifestation of severe debilitating symptoms, therapeutic interventions such as positive expiratory pressure (PEP) therapy and its variations (temporary, oscillatory) have been devised to mitigate lung hyperinflation. However, the efficacy of these interventions remains to be conclusively demonstrated. METHODS: A systematic review with meta-analysis of randomized trials was conducted following the PRISMA guidelines. Seven databases were screened with no date or language restriction. Two authors independently applied eligibility criteria and assessed the risk of bias of included studies using the Cochrane risk-of-bias tool. Outcomes were lung hyperinflation measures detected through changes in inspiratory capacity (IC), functional residual capacity (FRC), total lung capacity (TLC), and residual volume (RV), as well as FEV1, FVC, dyspnea, and physical capacity. Pooled standardized mean differences (SMDs) or mean differences (MDs) and 95% CI were calculated using a random-effects model. RESULTS: Seven trials, all with a high risk of bias, were included. Compared to control group, RV significantly decreased (4 studies, n = 231; SMD -0.42 [95% CI -0.77 to -0.08], P = .02), dyspnea improved (n = 321, SMD -1.17 [95% CI -1.68 to -0.66], P < .001), and physical capacity increased (5 studies, n = 311; MD 30.1 [95% CI 19.2-41.0] m, P < .001) with PEP therapy. There was no significant difference between PEP therapy and the control group in TLC, FVC, or FEV1. Only one study reported changes in inspiratory capacity as well as FRC. CONCLUSIONS: In patients with COPD, the effect of PEP therapy on lung hyperinflation is unclear owing to the non-consistent change in lung hyperinflation outcomes, insufficient data, and lack of high-quality trials. Dyspnea and physical capacity might improve with PEP therapy.


Assuntos
Respiração com Pressão Positiva , Doença Pulmonar Obstrutiva Crônica , Volume Residual , Humanos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/terapia , Respiração com Pressão Positiva/métodos , Capacidade Pulmonar Total , Ensaios Clínicos Controlados Aleatórios como Assunto , Capacidade Residual Funcional , Dispneia/terapia , Dispneia/etiologia , Dispneia/fisiopatologia , Capacidade Inspiratória/fisiologia , Pulmão/fisiopatologia , Resultado do Tratamento , Capacidade Vital , Masculino , Feminino , Volume Expiratório Forçado
8.
Artigo em Inglês | MEDLINE | ID: mdl-38298918

RESUMO

Purpose: To evaluate the degree of lung hyperinflation (LH) in patients with stable chronic obstructive pulmonary disease (COPD) by lung ultrasound score (LUS) and assess its value. Patients and Methods: We conducted a study of 149 patients with stable COPD and 100 healthy controls recruited by the Second Affiliated Hospital of Fujian Medical University. The pleural sliding displacement (PSD) was measured, the sliding of the pleura in different areas was observed, and LUS was calculated from both of them. The diaphragm excursion (DE), residual capacity (RV), total lung capacity (TLC), inspiratory capacity (IC) and functional residual capacity (FRC) were measured. We described the correlation between ultrasound indicators and pulmonary function indicators reflecting LH. Multiple linear regression analysis was used. The ROC curves of LUS and DE were drawn to evaluate their diagnostic efficacy, and De Long method was used for comparison. Results: (1) The LUS of patients with stable COPD were positively correlated with RV, TLC, RV/TLC and FRC and negatively correlated with IC and IC/TLC (r1=0.72, r2=0.41, r3=0.72, r4=0.70, r5=-0.56, r6=-0.65, P < 0.001). The correlation was stronger than that between DE at maximal deep inspiration and the corresponding pulmonary function indices (r1=-0.41, r2=-0.26, r3=-0.40, r4=-0.43, r5=0.30, r6=0.37, P < 0.001). (2) Multiple linear regression analysis showed that LUS were significantly correlated with IC/TLC and RV/TLC. (3) With IC/TLC<25% and RV/TLC>60% as the diagnostic criterion of severe LH, the areas under the ROC curves of LUS and DE at maximal deep inspiration for diagnosing severe LH were 0.914 and 0.385, 0.845 and 0.543, respectively (P < 0.001). Conclusion: The lung ultrasound score is an important parameter for evaluating LH. LUS is better than DE at maximal deep inspiration for diagnosing severe LH and is expected to become an effective auxiliary tool for evaluating LH.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Humanos , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Pulmão/diagnóstico por imagem , Capacidade Pulmonar Total , Capacidade Inspiratória , Capacidade Residual Funcional
9.
Am J Transplant ; 24(6): 928-932, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38346500

RESUMO

Size-matching donors to recipients in lung transplantation continues to be a clinical challenge. Predicted total lung capacity equations, or more simply, donor and recipient heights, while widely used, are imprecise and may not be representative of the pool of donors and recipients. These inherent limitations may result in size discrepancies. The advent of easily accessible software and the widespread availability of computed tomography (CT) imaging in donor assessments have made it possible to directly measure lung volumes in donors and recipients. As a result, there is a growing interest in adopting personalized CT volumetry as an alternative. This article explores both methods and underscores the potential benefits and precision offered by CT.


Assuntos
Transplante de Pulmão , Tomografia Computadorizada por Raios X , Humanos , Capacidade Pulmonar Total , Doadores de Tecidos , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Tamanho do Órgão
10.
Respir Med ; 222: 107524, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38176571

RESUMO

BACKGROUND: Previous studies have shown that the ratio between alveolar volume (VA) and total lung capacity (TLC) reflects ventilation heterogeneity in subjects with chronic obstructive pulmonary disease (COPD). However, the ratio and its correlation to respiratory symptoms had to our knowledge not previously been investigated in subjects with mild chronic airflow obstruction or without airflow obstruction (normal ratio FEV1/VC). The purpose of this study was to investigate potential connection between VA/TLC and respiratory symptoms, smoking habits and lung function parameters in subjects with normal spirometry and with mild chronic airflow obstruction. METHODS: We examined 450 subjects (82 non-smokers with normal spirometry, 298 subjects who smoked or had smoked earlier but had a normal spirometry and 70 subjects with chronical airflow obstruction) with routine lung function tests and a questionnaire regarding respiratory symptoms. RESULTS: This study showed 31 out of 54 subjects with a low VA/TLC had a normal ratio FEV1/VC. Of these subjects, 58.1 % had respiratory symptoms, compared to the group with normal ratio for both VA/TLC and FEV1/VC where 35.8 % had respiratory symptoms (p-value 0.02). CONCLUSION: This study has shown that within the group of subjects with a normal ratio FEV1/VC, those with a decreased ratio VA/TLC had a higher prevalence of respiratory symptoms compared to subjects with a normal VA/TLC ratio. These findings indicate that including the ratio VA/TLC in the evaluation of a pulmonary function test assessment might increase the possibility to identify subjects with early or at risk of lung disease.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Fumantes , Humanos , Volume Expiratório Forçado , Pulmão , Capacidade Pulmonar Total , Espirometria , Capacidade Vital
11.
J Appl Physiol (1985) ; 135(3): 534-541, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37439240

RESUMO

Sliding between lung lobes along lobar fissures is a poorly understood aspect of lung mechanics. The objective of this study was to test the hypothesis that lobar sliding helps reduce distortion in the lung parenchyma during breathing. Finite element models of left lungs with geometries and boundary conditions derived from medical images of human subjects were developed. Effect of lobar sliding was studied by comparing nonlinear finite elastic contact mechanics simulations that allowed and disallowed lobar sliding. Lung parenchymal distortion during simulated breath-holds and tidal breathing was quantified with the model's spatial mean anisotropic deformation index (ADI), a measure of directional preference in volume change that varies spatially in the lung. Models that allowed lobar sliding had significantly lower mean ADI (i.e., lesser parenchymal distortion) than models that disallowed lobar sliding under simulations of both tidal breathing (5.3% median difference, P = 0.008, n = 8) and lung deformation between breath-holds at total lung capacity and functional residual capacity (3.2% median difference, P = 0.03, n = 6). This effect was most pronounced in the lower lobe where lobar sliding reduced parenchymal distortion with statistical significance, but not in the upper lobe. In addition, more lobar sliding was correlated with greater reduction in distortion between sliding and nonsliding models in our study cohorts (Pearson's correlation coefficient of 0.95 for tidal breathing, 0.87 for breath-holds, and 0.91 for the combined dataset). These findings are consistent with the hypothesis that lung lobar sliding reduces parenchymal distortion during breathing.NEW & NOTEWORTHY The role of lobar sliding in lung mechanics is poorly understood. Delineating this role could help explain how breathing is affected by anatomical differences between subjects such as incomplete and missing lobar fissures. We used computational contact mechanics models of lungs from human subjects to delineate the effect of lobar sliding by comparing simulations that allowed and disallowed sliding. We found evidence consistent with the hypothesis that lung lobar sliding reduces parenchymal distortion during breathing.


Assuntos
Pulmão , Respiração , Humanos , Capacidade Residual Funcional , Capacidade Pulmonar Total , Testes de Função Respiratória
12.
Respir Physiol Neurobiol ; 316: 104124, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37499989

RESUMO

BACKGROUND: Current measures of tidal volume/forced vital capacity (VT/FVC) and VT/inspiratory capacity (VT/IC) at peak exercise cannot differentiate restrictive from obstructive ventilation patterns. This study aimed to investigate the utility of VT/total lung capacity (VT/TLC) as a marker for dynamic lung hyperinflation (DH) in patients with chronic obstructive pulmonary disease (COPD) and interstitial lung disease (ILD). METHODS: 267 subjects were screened: 23 ILD, 126 COPD, and 33 healthy individuals were enrolled. Lung function tests and cardiopulmonary exercise tests with repeated IC maneuver were conducted and compared at three exercise efforts: unloaded, middle of exercise, and peak exercise. RESULTS: During exercise, ILD patients demonstrated normal end-expiratory lung volume/TLC (EELV/TLC) ratios, but elevated end-inspiratory lung volume/TLC (EILV/TLC) ratios, except for peak exercise. COPD patients exhibited elevated ratios for both EELV/TLC and EILV/TLC during exercise with a larger EELV/TLC ratio compared to ILD patients at peak exercise (p < 0.05). The VT/TLC ratio distinguished ILD, COPD, and healthy controls at peak exercise (p < 0.05). A VT/TLC ratio of ≤ 0.22 or ≥ 0.30 indicated airflow obstruction with hyperinflation or normal lung expansion, respectively (AUC: 0.74 or 0.88). Furthermore, VT/TLC outperformed VT/FVC and VT/IC in differentiating lung expansion between ILD and COPD during exercise (all p < 0.05). CONCLUSION: Exercise-induced DH was absent in ILD patients but observed in COPD patients. Excessive lung expansion occurred in all patients during exercise, except for limited expansion in ILD at peak exercise probably due to specific lung properties. VT/TLC can distinguish between restrictive, obstructive, and normal ventilatory patterns.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Transtornos Respiratórios , Humanos , Volume de Ventilação Pulmonar , Volume Expiratório Forçado , Pulmão , Capacidade Pulmonar Total , Capacidade Inspiratória , Teste de Esforço
13.
PLoS One ; 18(6): e0287383, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37327210

RESUMO

Predicted lung volumes based on the Global Lung Function Initiative (GLI) model are used in pulmonary disease detection and monitoring. It is unknown how well the predicted lung volume corresponds with computed tomography (CT) derived total lung volume (TLV). The aim of this study was to compare the GLI-2021 model predictions of total lung capacity (TLC) with CT-derived TLV. 151 female and 139 male healthy participants (age 45-65 years) were consecutively selected from a Dutch general population cohort, the Imaging in Lifelines (ImaLife) cohort. In ImaLife, all participants underwent low-dose, inspiratory chest CT. TLV was measured by an automated analysis, and compared to predicted TLC based on the GLI-2021 model. Bland-Altman analysis was performed for analysis of systematic bias and range between limits of agreement. To further mimic the GLI-cohort all analyses were repeated in a subset of never-smokers (51% of the cohort). Mean±SD of TLV was 4.7±0.9 L in women and 6.2±1.2 L in men. TLC overestimated TLV, with systematic bias of 1.0 L in women and 1.6 L in men. Range between limits of agreement was 3.2 L for women and 4.2 L for men, indicating high variability. Performing the analysis with never-smokers yielded similar results. In conclusion, in a healthy cohort, predicted TLC substantially overestimates CT-derived TLV, with low precision and accuracy. In a clinical context where an accurate or precise lung volume is required, measurement of lung volume should be considered.


Assuntos
Pneumopatias , Pulmão , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Pulmão/diagnóstico por imagem , Medidas de Volume Pulmonar , Tomografia Computadorizada por Raios X/métodos , Capacidade Pulmonar Total
14.
Respir Res ; 23(1): 298, 2022 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-36316732

RESUMO

BACKGROUND: Preserved ratio impaired spirometry (PRISm) refers to decreased forced expiratory volume in 1 s (FEV1) in the setting of preserved ratio. Little is known about the role of PRISm and its complex relation with small airway dysfunction (SAD) and lung volume. Therefore, we aimed to investigate the associations between PRISm and SAD and lung volume. METHODS: We conducted a cross-sectional community-dwelling study in China. Demographic data, standard respiratory epidemiology questionnaire, spirometry, impulse oscillometry (IOS) and computed tomography (CT) data were collected. PRISm was defined as post-bronchodilator FEV1/FVC ≥ 0.70 and FEV1 < 80% predicted. Spirometry-defined SAD was defined as at least two of three of the post-bronchodilator maximal mid-expiratory flow (MMEF), forced expiratory flow 50% (FEF50), and forced expiratory flow 75% (FEF75) less than 65% of predicted. IOS-defined SAD and CT-defined gas trapping were defined by the fact that the cutoff value of peripheral airway resistance R5-R20 > 0.07 kPa/L/s and LAA- 856>20%, respectively. Analysis of covariance and logistic regression were used to determine associations between PRISm and SAD and lung volume. We then repeated the analysis with a lower limit of normal definition of spirometry criteria and FVC definition of PRISm. Moreover, we also performed subgroup analyses in ever smoker, never smoker, subjects without airway reversibility or self-reported diagnosed asthma, and subjects with CT-measured total lung capacity ≥70% of predicted. RESULTS: The final analysis included 1439 subjects. PRISm had higher odds and more severity in spirometry-defined SAD (pre-bronchodilator: odds ratio [OR]: 5.99, 95% confidence interval [95%CI]: 3.87-9.27, P < 0.001; post-bronchodilator: OR: 14.05, 95%CI: 8.88-22.24, P < 0.001), IOS-defined SAD (OR: 2.89, 95%CI: 1.82-4.58, P < 0.001), and CT-air trapping (OR: 2.01, 95%CI: 1.08-3.72, P = 0.027) compared with healthy control after adjustment for confounding factors. CT-measured total lung capacity in PRISm was lower than that in healthy controls (4.15 ± 0.98 vs. 4.78 ± 1.05 L, P < 0.05), after adjustment. These results were robust in repeating analyses and subgroup analyses. CONCLUSION: Our finding revealed that PRISm was associated with SAD and reduced total lung capacity. Future studies to identify the underlying mechanisms and longitudinal progression of PRISm are warranted.


Assuntos
Broncodilatadores , Doença Pulmonar Obstrutiva Crônica , Humanos , Volume Expiratório Forçado , Estudos Transversais , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Espirometria/métodos , Pulmão/diagnóstico por imagem , Capacidade Pulmonar Total , Capacidade Vital
15.
Chron Respir Dis ; 19: 14799731221133390, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36210794

RESUMO

Exertional dyspnea (ED) and impaired exercise performance (EP) are mainly caused by dynamic hyperinflation (DH) in chronic obstructive pulmonary disease (COPD) patients by constraining tidal volume expansion at peak exercise (VTpeak). As VTpeak is the product of inspiratory time (TIpeak) and flow (VT/TIpeak), it was hypothesized that VTpeak and VTpeak/total lung capacity (VTpeak/TLC) may be affected by TIpeak and VT/TIpeak. Hence, the study investigated the (1) effect of TIpeak and VT/TIpeak on VTpeak expansion, (2) factors associated with TIpeak, expiratory time (TEpeak), VT/TIpeak, and VTpeak/TLC, and (3) relationships between VT/TIpeak and VTpeak/TLC with ED and EP in COPD patients and controls. The study enrolled 126 male stable COPD patients and 33 sex-matched controls. At peak exercise, TIpeak was similar in all subjects (COPD versus controls, mean ± SD: 0.78 ± 0.17 s versus 0.81 ± 0.20 s, p = NS), whereas the COPD group had lower VT/TIpeak (1.71 ± 0.49 L/s versus 2.58 ± 0.69 L/s, p < .0001) and thus the COPD group had smaller VTpeak (1.31 ± 0.34 L versus 2.01 ± 0.45 L,p < .0001) and VTpeak/TLC (0.22 ± 0.06 vs 0.33 ± 0.05, p < .0001). TIpeak, TEpeak, and VT/TIpeak were mainly affected by exercise effort, whereas VTpeak/TLC was not. TEpeak, VT/TIpeak, and VTpeak/TLC were inversely changed by impaired lung function. TIpeak was not affected by lung function. Dynamic hyperinflation did not occur in the controls, however, VTpeak/TLC was strongly inversely related to DH (r = -0.79) and moderately to strongly related to lung function, ED, and EP in the COPD group. There was a slightly stronger correlation between VTpeak/TLC with ED and EP than VT/TIpeak in the COPD group (|r| = 0.55-0.56 vs 0.38-0.43). In summary, TIpeak was similar in both groups and the key to understanding how flow affects lung expansion. However, the DH volume effect was more important than the flow effect on ED and EP in the COPD group.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Dispneia/etiologia , Teste de Esforço/efeitos adversos , Volume Expiratório Forçado , Humanos , Capacidade Inspiratória , Pulmão , Masculino , Volume de Ventilação Pulmonar , Capacidade Pulmonar Total
16.
Int J Chron Obstruct Pulmon Dis ; 17: 1477-1482, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35774592

RESUMO

Body plethysmography is a fundamental method for the assessment of static lung volumes. Although equipment is provided by several manufacturers, there are no established cross-vendor tools for quality control. In the process of quality control and analysis of data on hyperinflation from the large COPD cohort COSYCONET, hints appeared that plethysmographs of different vendors might yield different values for static lung volumes. Functional residual capacity (FRC) differed about 0.67 litres between plethysmographs of the manufacturer Vyaire and Ganshorn. Absolute differences of residual lung volume (RV) and total lung capacity (TLC) were similar. It appears undeniable that differences of this magnitude have an impact on clinical interpretation. Thus, device harmonization seems to be required.


Assuntos
Pulmão , Doença Pulmonar Obstrutiva Crônica , Capacidade Residual Funcional , Humanos , Medidas de Volume Pulmonar , Pletismografia Total , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Volume Residual , Capacidade Pulmonar Total
17.
Sci Rep ; 12(1): 9579, 2022 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-35689019

RESUMO

The best available evidence and the predictive value of computed tomography (CT) findings for prognosis in patients with acute respiratory distress syndrome (ARDS) are unknown. We systematically searched three electronic databases (MEDLINE, CENTRAL, and ClinicalTrials.gov). A total of 410 patients from six observational studies were included in this systematic review. Of these, 143 patients (34.9%) died due to ARDS in short-term. As for CT grade, the CTs used ranged from 4- to 320-row. The index test included diffuse attenuations in one study, affected lung in one study, well-aerated lung region/predicted total lung capacity in one study, CT score in one study and high-resolution CT score in two studies. Considering the CT findings, pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 62% (95% confidence interval [CI] 30-88%), 76% (95% CI 57-89%), 2.58 (95% CI 2.05-2.73), 0.50 (95% CI 0.21-0.79), and 5.16 (95% CI 2.59-3.46), respectively. This systematic review revealed that there were major differences in the definitions of CT findings, and that the integration of CT findings might not be adequate for predicting short-term mortality in ARDS. Standardisation of CT findings and accumulation of further studies by CT with unified standards are warranted.


Assuntos
Síndrome do Desconforto Respiratório , Humanos , Pulmão , Prognóstico , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Capacidade Pulmonar Total
18.
Sci Total Environ ; 837: 155812, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35550893

RESUMO

Cement dust exposure (CDE) can be a risk factor for pulmonary disease, causing changes in segmental airways and parenchymal lungs. This study investigates longitudinal alterations in quantitative computed tomography (CT)-based metrics due to CDE. We obtained CT-based airway structural and lung functional metrics from CDE subjects with baseline CT and follow-up CT scans performed three years later. From the CT, we extracted wall thickness (WT) and bifurcation angle (θ) at total lung capacity (TLC) and functional residual capacity (FRC), respectively. We also computed air volume (Vair), tissue volume (Vtissue), global lung shape, percentage of emphysema (Emph%), and more. Clinical measures were used to associate with CT-based metrics. Three years after their baseline, the pulmonary function tests of CDE subjects were similar or improved, but there were significant alterations in the CT-based structural and functional metrics. The follow-up CT scans showed changes in θ at most of the central airways; increased WT at the subgroup bronchi; smaller Vair at TLC at all except the right upper and lower lobes; smaller Vtissue at all lobes in TLC and FRC except for the upper lobes in FRC; smaller global lung shape; and greater Emph% at the right upper and lower lobes. CT-based structural and functional variables are more sensitive to the early identification of CDE subjects, while most clinical lung function changes were not noticeable. We speculate that the significant long-term changes in CT are uniquely observed in CDE subjects, different from smoking-induced structural changes.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Poeira , Humanos , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Capacidade Pulmonar Total
20.
Physiol Rep ; 10(4): e15153, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35212176

RESUMO

Navy divers tend to have large lungs and low expiratory flow rates in the terminal portion of a spirogram. We examined Finnish Navy divers for the presence of air trapping, airway obstruction, and functional airway compression, and their association with lung volumes. Divers (n = 57) and non-diving men (n = 10) underwent a variety of pulmonary function tests. The amount of trapped air was calculated as the subtraction of the total lung capacity (TLC) measured in a single-breath helium dilution test from the TLC in body plethysmography (TLCb). Mean vital capacity (VC) was 6.4 L in the divers versus 5.8 L in the controls (p = 0.006) and TLCb 8.9 L in the divers versus 8.1 L in the controls (p = 0.002). No difference existed between them in the amount of trapped air. However, we found break points in a linear regression model (Davies test) between trapped air and several pulmonary parameters. Those individuals above the break points had lower ratio of forced expiratory volume in first second to forced vital capacity, lower resistance of airways, and higher reactance than those below the break points. In conclusion, navy divers had larger lungs than controls. Large lung volumes (VC >7.31 L or >122% of predicted value) were associated with air trapping. Furthermore, large volumes of air trapping (>1.1 L) were associated with increased residual volume (RV) and RV/TLCb. Despite no concurrent obstruction, functional airway compression, or reduced diffusing capacity, this slowly ventilated trapped air might remain disadvantageous for divers.


Assuntos
Pulmão , Volume Expiratório Forçado , Humanos , Masculino , Testes de Função Respiratória , Capacidade Pulmonar Total , Capacidade Vital
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...