1.
Interv Cardiol Clin ; 13(3): 385-398, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38839171

RESUMO

Congenital heart disease (CHD) is the most common congenital birth defect with an incidence of 1 in 100. Current survival to adulthood is expected in 9 out of 10 children with severe CHD as the diagnostic, interventional, and surgical success improves. The adult CHD (ACHD) population is increasingly diverse, reflecting the broad spectrum of CHD and evolution of surgical techniques to improve survival. Similarly, transcatheter interventions have seen exponential growth and creativity to reduce the need for repeat sternotomies. This article focuses on newer data and evolving techniques for transcatheter interventions specific to certain ACHD populations.


Assuntos
Cateterismo Cardíaco , Cardiopatias Congênitas , Humanos , Cardiopatias Congênitas/cirurgia , Cateterismo Cardíaco/métodos , Adulto , Procedimentos Cirúrgicos Cardíacos/métodos
2.
Interv Cardiol Clin ; 13(3): 369-384, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38839170

RESUMO

Over the last 2 decades, experience with transcatheter pulmonary valve replacement (TPVR) has grown significantly and has become an effective and reliable way of treating pulmonary valve regurgitation, right ventricular outflow (RVOT) obstruction, and dysfunctional bioprosthetic valves and conduits. With the introduction of self-expanding valves and prestents, dilated native RVOT can be addressed with the transcatheter approach. In this article, the authors review the current practices, technical challenges, and outcomes of TPVR.


Assuntos
Cateterismo Cardíaco , Cardiopatias Congênitas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Humanos , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Valva Pulmonar/cirurgia , Cardiopatias Congênitas/cirurgia , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico , Obstrução do Fluxo Ventricular Externo/cirurgia , Desenho de Prótese , Bioprótese
3.
Interv Cardiol Clin ; 13(3): 355-368, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38839169

RESUMO

Transcatheter ductal closure has proven to be safe and effective to occlude the patent ductus arteriosus (PDA) in premature infants. We have developed a robust multidisciplinary PDA program. After gaining experience performing transcatheter ductal closure in the cardiac catheterization laboratory, we transitioned to performing the procedure at the patient's bedside in the neonatal intensive care unit using echocardiographic guidance. The bedside approach has the potential to expand this therapy to patients who currently undergo expectant PDA management because of lack of availability of this therapy, and allow for earlier referral, which will reduce time of exposure to this pathologic shunt.


Assuntos
Cateterismo Cardíaco , Permeabilidade do Canal Arterial , Recém-Nascido Prematuro , Humanos , Permeabilidade do Canal Arterial/cirurgia , Permeabilidade do Canal Arterial/diagnóstico , Recém-Nascido , Cateterismo Cardíaco/métodos , Dispositivo para Oclusão Septal , Ecocardiografia/métodos
4.
Interv Cardiol Clin ; 13(3): 333-341, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38839167

RESUMO

The surgical pulmonary artery band was first introduced in 1952 and, to this day, can produce challenges in regard to the ideal amount of restriction and the need for reoperations. A transcatheter option may be the ideal solution as it allows for a less-invasive approach for a better hemodynamic assessment and easier re-intervention. To date, multiple approaches have been developed with device modifications to create restrictions to flow, each with advantages and limitations. Continued experience is still necessary to determine the ideal device to use to create an adequate and modifiable level of restriction.


Assuntos
Cardiopatias Congênitas , Artéria Pulmonar , Humanos , Cateterismo Cardíaco/métodos , Desenho de Equipamento , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/fisiopatologia , Hemodinâmica/fisiologia , Artéria Pulmonar/cirurgia
5.
J Cardiothorac Surg ; 19(1): 335, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38898495

RESUMO

BACKGROUND: Perioperative management and cardiac surgery in pregnant women with anti-phospholipid syndrome combined with heart valve disease have been rarely reported. CASE PRESENTATION: We describe a case of transcatheter mitral valve-in-valve replacement in a pregnant woman with bioprosthetic valve failure and anti-phospholipid syndrome at 18 weeks' gestation. The patient underwent a cesarean section delivery at 34 weeks of gestation, resulting in the birth of a healthy baby. CONCLUSIONS: Transapical mitral valve-in-valve surgery resulted in safe maternal and infant outcomes in a pregnant woman with anti-phospholipid syndrome combined with mitral bioprosthetic valve failure. The success of this procedure underscored the importance of multidisciplinary teamwork.


Assuntos
Síndrome Antifosfolipídica , Bioprótese , Implante de Prótese de Valva Cardíaca , Valva Mitral , Complicações Cardiovasculares na Gravidez , Humanos , Feminino , Gravidez , Síndrome Antifosfolipídica/complicações , Valva Mitral/cirurgia , Adulto , Implante de Prótese de Valva Cardíaca/métodos , Complicações Cardiovasculares na Gravidez/cirurgia , Próteses Valvulares Cardíacas , Cesárea , Cateterismo Cardíaco/métodos , Insuficiência da Valva Mitral/cirurgia , Falha de Prótese
6.
Cardiol Clin ; 42(3): 351-360, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38910020

RESUMO

Echocardiography, in all its forms (transthoracic echocardiography [TTE], transesophageal echocardiography [TEE], and intracardiac echocardiography [ICE]), is pivotal for the evaluation, guidance, and follow-up of transcatheter tricuspid edge-to-edge repair (TV-TEER) therapies. Although two-dimensional (2D) echocardiography remains essential, three-dimensional (3D) echo with multiplanar reconstruction (MPR) has revolutionized the field of structural imaging. In addition, the advent of 3D ICE has added an important modality to the imaging toolbox, particularly helpful when intraprocedural TEE images are challenging. In this review, we provide a detailed, step-by-step approach for advanced echocardiographic guidance of TV-TEER using 3D MPR.


Assuntos
Cateterismo Cardíaco , Ecocardiografia Tridimensional , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Cateterismo Cardíaco/métodos , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Ultrassonografia de Intervenção/métodos , Ecocardiografia/métodos
7.
Cardiol Clin ; 42(3): 417-431, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38910025

RESUMO

Patent foramen ovale (PFO) and atrial septal defects (ASDs) are two types of interatrial communications with unique clinical presentations and management strategies. The PFO is a normal part of fetal development that typically closes shortly after birth but may persist in as many as 25% to 30% of adults. The communication between atria may result in paradoxic embolism and embolic stroke. On the other hand, ASDs (anatomically defined as secundum, primum, sinus venosus, and coronary sinus in order of prevalence) typically result in right heart volume overload and are often associated with other congenital defects. The diagnostic methods, treatment options including surgical and percutaneous approaches, and potential complications are described. Both conditions underline the significance of precise diagnosis and appropriate management to mitigate risks and ensure optimal patient outcomes.


Assuntos
Forame Oval Patente , Comunicação Interatrial , Humanos , Forame Oval Patente/complicações , Forame Oval Patente/cirurgia , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/complicações , Comunicação Interatrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia Transesofagiana/métodos , Cateterismo Cardíaco/métodos , Dispositivo para Oclusão Septal , Saúde Global
8.
Cardiol Clin ; 42(3): 447-454, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38910027

RESUMO

Mitral valve stenosis remains highly prevalent among the US population although with dramatically shifting demographics. The significance of rheumatic mitral disease in developing nations persists, despite improvements in preventative measures and early detection, and its presence in developed countries is still evident as observed through international migration. In addition, the substantial growth in the aging population with a heightened occurrence of concurrent cardiovascular risk factors is leading to an increased prevalence of chronic calcific degeneration and degeneration of previously repaired or replaced valves. This article aims to review various transcatheter therapies in the treatment of mitral valve stenosis.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Estenose da Valva Mitral , Valva Mitral , Humanos , Estenose da Valva Mitral/cirurgia , Estenose da Valva Mitral/terapia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Próteses Valvulares Cardíacas
9.
Cardiol Clin ; 42(3): 389-401, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38910023

RESUMO

The left atrial appendage (LAA) has gained increasing attention in the field of cardiology as a potential site for intervention in patients with atrial fibrillation (AF) and an elevated risk of thromboembolic events. Left atrial appendage occlusion (LAAO) has emerged as a promising therapeutic strategy to mitigate the risk of stroke and systemic embolism, especially in individuals who are unsuitable candidates for long-term anticoagulation therapy. This review aims to provide a comprehensive analysis of the current state of LAAO, encompassing its anatomic considerations, procedural techniques, clinical outcomes, and future directions.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/cirurgia , Fibrilação Atrial/terapia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/etiologia , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/tendências , Procedimentos Cirúrgicos Cardíacos/métodos , Dispositivo para Oclusão Septal , Tromboembolia/prevenção & controle , Tromboembolia/etiologia , Oclusão do Apêndice Atrial Esquerdo
10.
Echocardiography ; 41(6): e15822, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38853621

RESUMO

BACKGROUND: Balloon sizing (BS) has been used for device size selection in percutaneous atrial septal defect (ASD) closure. Due to its limitations, alternative imaging techniques like three-dimensional transesophageal echocardiography (3D-TEE) are valuable for guiding ASD device size selection during ASD closure procedures. The purpose of this study was to compare ASD sizing using measurements obtained from 3D-TEE to those utilizing the standard balloon sizing method. METHODS: We identified 53 patients with single secundum type ASD without PFO who underwent percutaneous closure at the Tehran Heart Center between 2019 and 2022. Balloon sizing was performed in all patients with the stop-flow technique, and the choice of device size was determined based on the sizing derived from BS. 3D-TEE imaging was performed before the intervention, and the ASD shape and quality of ASD rims were assessed. RESULTS: Among the 53 patients who underwent single ASD device closure, multiple 3D TEE measurements significantly correlated with balloon sizing results. This included defect area, perimeter, and diameter obtained from 3D-TEE images multi-planar reconstruction. ASD perimeter detected by 3D TEE had the best correlation with BS results. When divided by the shape of ASD, there was no significant difference between our 3D-images data and BS in round or oval-shaped ASDs. CONCLUSION: The 3D-TEE study is reliable for assessing ASD configurational characteristics in percutaneous device closure candidates. 3D-TEE has the potential to accurately determine the appropriate device size and reduce complications, costs, and procedural duration. Further research is needed to validate these findings and establish the role of 3D-TEE measurements in guiding the best treatment decisions for ASD closure.


Assuntos
Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Comunicação Interatrial , Dispositivo para Oclusão Septal , Humanos , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Tridimensional/métodos , Masculino , Comunicação Interatrial/cirurgia , Comunicação Interatrial/diagnóstico por imagem , Feminino , Adulto , Pessoa de Meia-Idade , Adolescente , Desenho de Prótese , Cateterismo Cardíaco/métodos , Reprodutibilidade dos Testes , Adulto Jovem
11.
Echocardiography ; 41(6): e15861, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38853674

RESUMO

BACKGROUND: Transesophageal echocardiography (TEE) is primarily used to guide transcatheter structural heart interventions, such as tricuspid transcatheter edge-to-edge repair (TEER). Although TEE has a good safety profile, it is still an invasive imaging technique that may be associated with complications, especially when performed during long transcatheter procedures or on frail patients. The aim of this study was to assess TEE-related complications during tricuspid TEER. METHODS: This is a prospective study enrolling 53 patients who underwent tricuspid TEER for severe tricuspid regurgitation (TR). TEE-related complications were assessed clinically and divided into major (life-threatening, major bleeding requiring transfusions or surgery, organ perforation, and persistent dysphagia) and minor (perioral hypesthesia, < 24 h dysphagia/odynophagia, minor intraoral bleeding and hematemesis not requiring transfusion) RESULTS: The median age of the patient population was 79 years; 43.4% had severe, 39.6% massive, and 17.6% torrential TR. 62.3% of patients suffered from upper gastrointestinal disorders. Acute procedural success (APS) was achieved in 88.7% in a median device time of 36 min. A negative association was shown between APS and lead-induced etiology (r = -.284, p = .040), baseline TR grade (r = -.410, p = .002), suboptimal TEE view (r = -.349, p = .012), device time (r = -.234, p = .043), and leaflet detachment (r = -.496, p < .0001). We did not observe any clinical manifest major or minor TEE-related complications during the hospitalization. CONCLUSIONS: Our study reinforces the good safety profile and efficacy of TEE guidance during tricuspid TEER. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious complications. Furthermore, suboptimal intraprocedural TEE views are associated with lower TR reduction rates. HIGHLIGHTS: Transesophageal echocardiography is a crucial and safe technique for guiding transcatheter structural heart interventions. A mix of mid/deep esophageal and trans gastric views, as well as real-time 3D imaging is generally used to guide the procedure. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious problems. A shorter device time is associated with more rarely probe-related complications. Suboptimal intraprocedural TEE views are associated with lower TR reduction rates.


Assuntos
Ecocardiografia Transesofagiana , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Ecocardiografia Transesofagiana/métodos , Feminino , Masculino , Estudos Prospectivos , Insuficiência da Valva Tricúspide/cirurgia , Idoso , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Idoso de 80 Anos ou mais
12.
EuroIntervention ; 20(11): e718-e727, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38840576

RESUMO

BACKGROUND: Left atrial appendage occlusion (LAAO) is performed increasingly, but long-term follow-up imaging data are lacking. AIMS: The aim of this study was to evaluate the safety and durability of the Amplatzer Amulet device >4 years after LAAO. METHODS: This was a prospective observational cohort study including 52 patients implanted with the Amplatzer Amulet device at Aarhus University Hospital, Denmark. A >4-year follow-up cardiac computed tomography (CT) scan after LAAO was performed and compared with the results from the 2-month and 12-month scans. The primary outcome was left atrial appendage (LAA) sealing based on distal LAA contrast patency and peridevice leakage (PDL), stratified into complete occlusion (grade 0 [G0]) and grade 1-3 leakage (G1-3), respectively. Secondary outcomes were low- and high-grade hypoattenuated thickening (HAT), device-related thrombosis (DRT) and device durability. RESULTS: The median (interquartile range [IQR]) follow-up time from LAAO to the latest CT scan was 5.8 years (4.5; 6.3). At 2-month (n=52), 12-month (n=27) and >4-year CT follow-ups (n=52), rates of both complete occlusion (33%, 37%, 35%) and G2 leaks (52%, 52%, 48%) remained stable. Rates of G1 leaks varied (14%, 4%, 6%) and G3 leaks rose (2%, 7%, 12%) from earliest to latest follow-up. The median left atrial (LA) volume increased from 127 mL (96; 176) to 144 mL (108; 182) and 147 mL (107; 193). No DRT was found. The structural device integrity was preserved. CONCLUSIONS: This study indicates a stable LAA sealing status throughout the follow-up period, emphasising the importance of the procedural result in avoiding PDL. Few patients displayed PDL progression, which might partly be related to LA remodelling with increasing volume. The long-term device durability appears excellent. Larger studies are warranted to confirm these findings.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Tomografia Computadorizada por Raios X , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Apêndice Atrial/fisiopatologia , Masculino , Feminino , Idoso , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Estudos Prospectivos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Seguimentos , Pessoa de Meia-Idade , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação
14.
Interv Cardiol Clin ; 13(3): 291-306, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38839164

RESUMO

Superior sinus venosus defects (SVD) are interatrial communications located above the confines of the oval fossa, where unroofing of the right upper pulmonary vein leads to its anomalous drainage to the superior venacava. Recent emergence of transcatheter closure of these defects using covered stents is an attractive alternative option especially in adults with additional comorbidities. This article focuses on various aspects of non-surgical closure of SVD, including patient selection, appropriate hardware options, step-by-step procedural details, evolution and modifications in the techniques over the last decade, protocols for follow-up evaluation, and potential complications associated with this intervention.


Assuntos
Cateterismo Cardíaco , Stents , Humanos , Cateterismo Cardíaco/métodos , Comunicação Interatrial/cirurgia , Desenho de Prótese , Veia Cava Superior/anormalidades , Veia Cava Superior/cirurgia
15.
Interv Cardiol Clin ; 13(3): 399-408, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38839172

RESUMO

Hybrid interventions in congenital heart disease (CHD) embody the inherent collaboration between congenital interventional cardiology and cardiothoracic surgery. Hybrid approaches to complex and common lesions provide the opportunity to circumvent the limitations of patient size, vascular access, severity of illness, and anatomy that would otherwise be prohibitive to surgical and percutaneous techniques alone. This review describes several important hybrid approaches to interventions in CHD.


Assuntos
Cardiopatias Congênitas , Humanos , Cardiopatias Congênitas/cirurgia , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos
16.
Interv Cardiol Clin ; 13(3): 421-430, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38839174

RESUMO

Since PDA stenting was first attempted in the early 1990s, significant technical advancements have improved outcomes and some centers have even transitioned to exclusive PDA stenting for all infants with duct-dependent pulmonary circulation. In addition to its use in infants with duct-dependent pulmonary circulation, PDA stenting has also been adapted as a percutaneous palliative option for suprasystemic pulmonary arterial hypertension and as a component of the hybrid procedure. In this article, the authors aim to review indications and outcomes for PDA stenting, describe the procedure, and discuss future directions.


Assuntos
Permeabilidade do Canal Arterial , Stents , Humanos , Permeabilidade do Canal Arterial/cirurgia , Cateterismo Cardíaco/métodos , Cuidados Paliativos/métodos , Resultado do Tratamento
18.
Sci Rep ; 14(1): 11504, 2024 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-38769360

RESUMO

Pressure drifting is a troublesome error in invasive coronary function tests. This study aimed to evaluate the relationship between prolonged and short-time pressure equalizations in pressure drifting. Pressure drifting was defined as the pressure gradient between the mean pressure of the distal wire sensor (Pd) and aortic pressure (Pa) when the wire was withdrawn to the tip of the guiding catheter. Significant drifts 1 and 2 were defined as the absolute values of pressure gradients > 2 and > 3 mmHg, respectively. A logistic regression model was used to evaluate the associations between prolonged pressure equalization and each pressure drifting. The prolonged pressure equalization strategy was associated with a lower incidence of drift 1 than the short-time pressure equalization strategy (6.84% vs. 16.92%, p < 0.05). However, no statistical differences were found in the incidence of drift 2 between the prolonged and short-time pressure equalization strategies (4.27% vs. 7.69%, p = 0.34). In the multivariable regression model, only the prolonged pressure equalization strategy predicted a lower incidence of pressure drift 1. In conclusion, the prolonged pressure equalization strategy was associated with a lower incidence of significant pressure drifting with more stringent thresholds than the short-time pressure equalization strategy.


Assuntos
Cateterismo Cardíaco , Humanos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Cateterismo Cardíaco/métodos , Pressão , Pressão Sanguínea/fisiologia
19.
Artigo em Inglês | MEDLINE | ID: mdl-38727533

RESUMO

Preoperative calculations showed that the 9-mm inlet, 6-mm outlet, 25-cc pump chambers and 65-73 bpm would be optimal for a 5-year-old patient suffering from restrictive cardiomyopathy, with a body surface area of 0.59 m2 (1.5 L/min flow for a cardiac index of 2.5). After re-sternotomy and standard bicaval cannulation for cardiopulmonary bypass, the procedure was performed under normothermic conditions and on the beating heart. Biventricular support was established with the Berlin Heart Excor using biatrial cannulation. For left atrial cannulation, induced ventricular fibrillation was used. The 9-mm inlet cannulas were inserted into the left and right atria, respectively. The 6-mm outlet cannulas were implanted using 8-mm interposition vascular grafts for the aorta and the main pulmonary artery, respectively. Cannulas were tunnelled through the epigastric space, with systems crossing outside of the body. The 25-cc chambers were used for both right ventricular assist device and left ventricular assist device support, which subsequently showed full emptying and filling.


Assuntos
Cardiomiopatia Restritiva , Coração Auxiliar , Humanos , Cardiomiopatia Restritiva/cirurgia , Cardiomiopatia Restritiva/diagnóstico , Masculino , Pré-Escolar , Átrios do Coração/cirurgia , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/instrumentação , Insuficiência Cardíaca/cirurgia , Implantação de Prótese/métodos