Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.209
Filtrar
1.
J Pharm Biomed Anal ; 250: 116389, 2024 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-39116584

RESUMO

Immunosuppressive drugs (ISDs) are given to avoid the allograft rejection after transplantation. The concentrations of ISDs should be closely monitored owing to their wide inter-individual variability in its pharmacokinetics and narrow therapeutic window. Currently, the whole blood concentration measurement is the major approach of therapeutic drug monitoring of clinical ISDs in organ transplantation. Its correlation with the efficacy of ISDs remains elusive. While the acute rejection after transplantation may occur even when whole-blood ISDs concentrations are within the target range. Since the site of action of ISDs are within the lymphocyte, direct measurement of drug exposure in target cells may more accurately reflect the clinical efficacy of ISDs. Although several methods have been developed for the peripheral blood mononuclear cells (PBMCs) extraction and drug concentration measurement, the complex pre-processing has limited the study of the relationship between intracellular ISDs concentrations and the occurrence of rejection. In this study, the extraction of ISDs in PBMCs was carried out by the liquid-liquid extraction with low temperature purification, without centrifugation. The lower limit of quantitation were 0.2 ng/mL for cyclosporine A, tacrolimus and sirolimus, 1.0 ng/mL for mycophenolic acid, and the within-run and between-run coefficient of variations were both less than 12.4 %. The calibration curves of mycophenolic acid had a linear range (ng/mL): 1.0-128.0 (r2 = 0.9992). The calibration curves of other three ISDs had a linear range (ng/mL): 0.2-20.48 (r2 > 0.9956). A total of 157 clinical samples were analyzed by the UPLC-MS/MS for ISDs concentration in blood or plasma ([ISD]blood or plasma) and the concentration within PBMCs ([ISD]PBMC). Although there was strong association between [ISD]PBMC and [ISD]blood or plasma, the large discrepancies between concentration within [ISD]blood or plasma and [ISD]PBMC were observed in a small proportion of clinical samples. The developed method with short analysis time and little amounts of blood sample can be successfully applied to therapeutic drug monitoring of ISDs in PBMCs for analysis of large numbers of clinical samples and is helpful to explore the clinical value of ISDs concentration in PBMCs.


Assuntos
Monitoramento de Medicamentos , Imunossupressores , Leucócitos Mononucleares , Extração Líquido-Líquido , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Extração Líquido-Líquido/métodos , Imunossupressores/sangue , Cromatografia Líquida de Alta Pressão/métodos , Monitoramento de Medicamentos/métodos , Tacrolimo/sangue , Ácido Micofenólico/sangue , Ácido Micofenólico/farmacocinética , Ciclosporina/sangue , Reprodutibilidade dos Testes , Limite de Detecção , Sirolimo/sangue , Espectrometria de Massa com Cromatografia Líquida
2.
Clin Chim Acta ; 562: 119877, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39025199

RESUMO

BACKGROUND AND AIMS: Ciclosporin (CSA) is an immunosuppressive agent that requires therapeutic drug monitoring (TDM). High partitioning in erythrocytes indicates that whole blood (WB) is a suitable matrix for CSA determination. Alternative sampling strategies, such as volumetric absorptive microsampling (VAMS), are novel possibilities for blood collection during TDM for various analytes, including immunosuppressants. This technique is attractive for vulnerable pediatric patients, including home-based self-sampling, remote therapy, and adherence control. MATERIALS AND METHODS: This study aimed to develop and validate a new method for CSA determination based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) of WB and VAMS samples. Additionally, these methods were applied for CSA determination in clinical samples from pediatric transplant recipients. A strong point of this study is the assessment of an external proficiency testing scheme. RESULTS: Both methods were successfully validated within the 1-2000 ng/mL calibration range, with LOD 0.5 and 1 ng/mL for WB and VAMS methods, respectively. All the validation parameters fulfilled the international acceptance criteria for bioanalytical methods. Cross-validation confirmed the interchangeability of the LC-MS/MS method developed in this study. CONCLUSION: This study developed and validated novel methods for CSA determination in whole blood and VAMS using LC-MS/MS. Clinical validation and proficiency testing confirmed their utility in routine clinical practice.


Assuntos
Ciclosporina , Monitoramento de Medicamentos , Imunossupressores , Transplante de Rim , Espectrometria de Massas em Tandem , Humanos , Ciclosporina/sangue , Ciclosporina/uso terapêutico , Monitoramento de Medicamentos/métodos , Criança , Imunossupressores/sangue , Imunossupressores/uso terapêutico , Cromatografia Líquida , Transplantados , Coleta de Amostras Sanguíneas , Adolescente , Pré-Escolar
3.
Artigo em Inglês | MEDLINE | ID: mdl-38749100

RESUMO

Cyclosporine A (CsA) is a widely used immunosuppressive drug with a narrow therapeutic index and large individual differences. Its therapeutic and toxic effects are closely related to blood drug concentrations, requiring routine therapeutic drug monitoring (TDM). The current main methods for TDM of CsA are enzyme multiplied immunoassay technique (EMIT) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). However, few study on the method comparison of the EMIT and LC-MS/MS for the measurement of whole blood CsA concentration in children has been reported. In this study, we developed a simple and sensitive LC-MS/MS assay for the determination of CsA, and 657 cases of CsA concentrations were determined from 197 pediatric patients by a routine EMIT assay and by the validated in-house LC-MS/MS method on the same batch of samples, aimed to address the aforementioned concern. Consistency between the two assays was evaluated using linear regression and Bland-Altman analysis. The linear range of LC-MS/MS was 0.500-2000 ng/mL and that of the EMIT was 40-500 ng/mL, respectively. Overall, the correlation between the two methods was significant (r-value ranging from 0.8842 to 0.9441). Unsatisfactory consistency was observed in the concentrations < 40 ng/mL (r = 0.7325) and 200-500 ng/mL (r = 0.6851). Bland-Altman plot showed a mean bias of -18.0 % (±1.96 SD, -73.8 to 37.8 %) between EMIT and LC-MS/MS. For Passing-Bablok regression between EMIT and LC-MS/MS did not differ significantly (p > 0.05). In conclusion, the two methods were closely correlated, but the CsA concentration by LC-MS/MS assay was slightly higher than that by EMIT method. Switching from the EMIT assay to the LC-MS/MS method was acceptable, and the LC-MS/MS method will receive broader application in clinical settings due to its better analytical capabilities, but the results need to be further verified in different laboratories.


Assuntos
Ciclosporina , Monitoramento de Medicamentos , Espectrometria de Massas em Tandem , Humanos , Ciclosporina/sangue , Espectrometria de Massas em Tandem/métodos , Modelos Lineares , Cromatografia Líquida/métodos , Criança , Monitoramento de Medicamentos/métodos , Reprodutibilidade dos Testes , Técnica de Imunoensaio Enzimático de Multiplicação , Pré-Escolar , Masculino , Limite de Detecção , Lactente , Imunossupressores/sangue , Imunossupressores/farmacocinética , Feminino , Adolescente , Espectrometria de Massa com Cromatografia Líquida
4.
J Appl Lab Med ; 9(3): 573-578, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38300648

RESUMO

BACKGROUND: An erroneously high tacrolimus level was reported to a clinician. A root cause analysis investigation failed to determine the cause of the error. It was suspected that the incorrect preanalytical extraction reagent and procedure was used during testing; however, how this would affect the assayed drug concentration was unclear. Here we investigated the effect of the substitution of sirolimus, tacrolimus, and cyclosporine extraction reagents on assayed drug concentration. METHODS: Tacrolimus, sirolimus, and cyclosporine concentration were measured on the Abbott Architect i2000 analyzer. Each assay requires a preanalytical extraction step, with a distinct reagent. We investigated the effect of the substitution of the extraction reagents and procedure between the 3 assays on the measured drug concentration. Two experiments were performed, one on samples of known drug concentration and one on samples with no drug present. RESULTS: Substituting cyclosporine and sirolimus extraction procedures increased assayed tacrolimus concentrations from 5.6 to 8.47 (+51.25%) and 8.13 (+45.18%) ng/mL, respectively. Extraction procedure substitutions decreased assayed sirolimus from 13.63 to 4.60 (-66.25%) and 8.07 (-40.79%) ng/mL for cyclosporine and tacrolimus. Cyclosporine concentration increased from 274.60 to 391.30 (+42.50%) ng/mL using sirolimus extraction reagents and to 757.30 (+175.78%) ng/mL using tacrolimus extraction reagents. Cross-reactivity was observed between the tacrolimus assay and sirolimus and cyclosporine extraction reagents. CONCLUSIONS: Significant changes, both positive and negative, are observed in assayed drug concentration when incorrect extraction procedures are used in the Abbott i2000 tacrolimus, sirolimus, and cyclosporine assays. Preanalytic extraction procedures should be investigated when performing root cause analysis for erroneous therapeutic drug values.


Assuntos
Ciclosporina , Imunossupressores , Sirolimo , Tacrolimo , Tacrolimo/sangue , Tacrolimo/análise , Sirolimo/sangue , Sirolimo/análise , Ciclosporina/sangue , Ciclosporina/análise , Humanos , Imunossupressores/sangue , Imunossupressores/análise , Monitoramento de Medicamentos/métodos , Automação Laboratorial
5.
Angew Chem Int Ed Engl ; 61(6): e202109005, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34633119

RESUMO

Protein biosensors play an increasingly important role as reporters for research and clinical applications. Here we present an approach for the construction of fully integrated but modular electrochemical biosensors based on the principal component of glucose monitors PQQ-glucose dehydrogenase (PQQ-GDH). We designed allosterically regulated circular permutated variants of PQQ-GDH that show large (>10-fold) changes in enzymatic activity following intramolecular scaffolding of the newly generated N- and C termini by ligand binding domain/ligand complexes. The developed biosensors demonstrated sub-nanomolar affinities for small molecules and proteins in colorimetric and electrochemical assays. For instance, the concentration of Cyclosporine A could be measured in 1 µL of undiluted blood with the same accuracy as the leading diagnostic technique that uses 50 times more sample. We further used this biosensor to construct highly porous gold bioelectrodes capable of robustly detecting concentrations of Cyclosporine A as low as 20 pM and retained functionality in samples containing at least 60 % human serum.


Assuntos
Técnicas Biossensoriais , Ciclosporina/sangue , Técnicas Eletroquímicas , Glucose Desidrogenase/química , Glucose Desidrogenase/metabolismo , Humanos
6.
AAPS PharmSciTech ; 22(4): 155, 2021 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-33987739

RESUMO

The objectives of current investigation are (1) to find out wavelength of maximum absorbance (λmax) for combined cyclosporin A and etodolac solution followed by selection of mobile phase suitable for the RP-HPLC method, (2) to define analytical target profile and critical analytical attributes (CAAs) for the analytical quality by design, (3) to screen critical method parameters with the help of full factorial design followed by optimization with face-centered central composite design (CCD) approach-driven artificial neural network (ANN)-linked with the Levenberg-Marquardt (LM) algorithm for finding the RP-HPLC conditions, (4) to perform validation of analytical procedures (trueness, linearity, precision, robustness, specificity and sensitivity) using combined drug solution, and (5) to determine drug entrapment efficiency value in dual drug-loaded nanocapsules/emulsions, percentage recovery value in human plasma spiked with two drugs and solution state stability analysis at different stress conditions for substantiating the double-stage systematically optimized RP-HPLC method conditions. Through isobestic point and scouting step, 205 nm and ACN:H2O mixture (74:26) were selected respectively as the λmax and mobile phase. The ANN topology (3:10:4) indicating the input, hidden and output layers were generated by taking the 20 trials produced from the face-centered CCD model. The ANN-linked LM model produced minimal differences between predicted and observed values of output parameters (or CAAs), low mean squared error and higher correlation coefficient values in comparison to the respective values produced by face-centered CCD model. The optimized RP-HPLC method could be applied to analyze two drugs concurrently in different formulations, human plasma and solution state stability checking.


Assuntos
Ciclosporina/análise , Etodolac/análise , Aprendizado de Máquina , Nanocápsulas/análise , Redes Neurais de Computação , Algoritmos , Antifúngicos/análise , Antifúngicos/sangue , Antifúngicos/química , Inteligência Artificial/tendências , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia de Fase Reversa/métodos , Ciclosporina/sangue , Ciclosporina/química , Emulsões , Etodolac/sangue , Etodolac/química , Humanos , Aprendizado de Máquina/tendências , Nanocápsulas/química , Projetos de Pesquisa
7.
Biomed Res Int ; 2021: 3108749, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33928146

RESUMO

AIM: To develop a population pharmacokinetic model for Uruguayan patients under treatment with cyclosporine (CsA) that can be applied to TDM. Patients and Methods. A total of 53 patients under treatment with CsA were included. 37 patients with at least one pharmacokinetic profile described with four samples were considered for model building, while the remaining 16 were considered for the assessments of predictive performances. Pharmacokinetic parameter estimation was performed using a nonlinear mixed effect modelling implemented in the Monolix® software (version 2019R1, Lixoft, France); meanwhile, simulations were performed in R v.3.6.0 with the mlxR package. RESULTS: A two-compartment model with a first-order disposition model including lag time was used as a structural model. The final model was internally validated using prediction corrected visual predictive check (pcVPC) and other graphical diagnostics. A total of 621 CsA steady-state concentrations were analyzed for model development. Population estimates for the absorption constant (ka) and lag time were 0.523 h-1 and 0.512 h, respectively; apparent clearance (CL/F) was 30.3 L/h (relative standard error [RSE] ± 8.25%) with an interindividual variability of 39.8% and interoccasion variability of 38.0%; meanwhile, apparent clearance of distribution (Q/F) was 17.0 L/h (RSE ± 12.1%) with and interindividual variability of 53.2%. The covariate analysis identified creatinine clearance (ClCrea) as an individual factor influencing the Cl of CsA. The predictive capacity of the population model was demonstrated to be effective since predictions made for new patients were accurate for C1 and C2 (MPPEs below 50%). Bayesian forecasting improved significantly in the second and third occasions. CONCLUSION: A population pharmacokinetic model was developed to reasonably estimate the individual cyclosporine clearance for patients. Hence, it can be utilized to individualize CsA doses for prompt and adequate achievement of target blood concentrations of CsA.


Assuntos
Ciclosporina/farmacocinética , Monitoramento de Medicamentos , Modelos Biológicos , Adulto , Ciclosporina/sangue , Feminino , Humanos , Masculino
8.
Biomed Chromatogr ; 35(8): e5128, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33780006

RESUMO

Because either trough or peak concentration at 2 h after administration is measured in routine therapeutic drug monitoring for cyclosporine A (CyA), a quantification method with a wide-range calibration curve capable of simultaneously measuring both concentrations is required. We developed a sensitive, wide-range and high-throughput quantification method for CyA in whole blood using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), and compared patients' blood CyA levels measured by UPLC-MS/MS and antibody-conjugated magnetic immunoassay (ACMIA). Whole blood samples were prepared by solid-phase extraction using Oasis HLB µElution plate. The UPLC-MS/MS assay showed excellent linearity over a wide calibration range of 5-2500 ng/mL. Within-batch accuracy and precision as well as batch-to-batch accuracy and precision fulfilled the criteria of US Food and Drug Administration guidelines. The blood CyA concentrations measured by the UPLC-MS/MS assay correlated strongly with those measured by ACMIA. A Bland-Altman plot showed a fixed error between CyA concentrations measured by the two methods, and the concentrations measured by the UPLC-MS/MS method were consistently lower than those measured by ACMIA. We have succeeded to develop a sensitive, wide-range and high-throughput quantification method for CyA in whole blood using UPLC-MS/MS.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Ciclosporina/sangue , Imunoensaio/métodos , Espectrometria de Massas em Tandem/métodos , Idoso , Anticorpos/química , Ciclosporina/isolamento & purificação , Feminino , Humanos , Modelos Lineares , Imãs/química , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Biomed Chromatogr ; 35(6): e5071, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33462848

RESUMO

The aim of this study was to develop and validate a UHPLC-MS/MS assay to quantify cyclosporin (CYC), tacrolimus (TAC), sirolimus (SIR) and everolimus (EVE) in human whole blood for therapeutic drug monitoring. Analytes were extracted from 50 µL human whole blood by protein precipitation. The separation of the drugs was performed on an Acquity UPLC BEH C18 column. Analytes were eluted with a mobile phase consisting of 2 mM ammonium acetate with 0.1% formic acid (v/v) in deionised water and 2 mM ammonium acetate with 0.1% formic acid (v/v) in methanol at a flow rate of 300 µL/min in gradient elution. The method performance was evaluated by analysing patient blood samples and/or external quality control samples [proficiency testing (PT) scheme]. The method was linear from 23.75 to 1094.0, 1.3 to 42.4, 1.3 to 47.0 and 1.2-41.6 µg/mL for CYC, TAC, SIR and EVE, respectively. The within- and between-assay reproducibility results were ˂ 11%. Results from PT and patient sample quantification were comparable to those obtained previously by an in-house validated method using protein precipitation and liquid-liquid extraction. This method showed good analytical performance for quantifying CYC, TAC, SIR and EVE in whole blood over their respective calibration ranges.


Assuntos
Ciclosporina/sangue , Monitoramento de Medicamentos/métodos , Everolimo/sangue , Imunossupressores/sangue , Sirolimo/sangue , Tacrolimo/sangue , Cromatografia Líquida de Alta Pressão , Humanos , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem
10.
Eur J Clin Pharmacol ; 77(7): 961-969, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33484274

RESUMO

PURPOSE: To identify the risk factors of calcineurin inhibitor (CNI)-associated new-onset diabetes mellitus (NODM) in chronic kidney disease (CKD) treatment. METHODS: We retrospectively screened patients treated with CNIs in our hospital from January 2015 to December 2018. The inclusion criteria were as follows: a clear diagnosis of CKD and patients receiving CNI treatment. We compared patients with and without CNI-associated NODM. RESULTS: Ninety-eight of the 336 assessed patients met the inclusion criteria, 15 (15.3% [15/98]) of whom developed CNI-associated NODM. Multiple logistic regression analysis revealed that baseline glycosylated hemoglobin (OR=4.141; 1.024-16.743; p=0.046) and CNI trough concentration (1 year) (OR=1.028; 1.009-1.047, p=0.004) were independent risk factors for NODM. In contrast, glucocorticoid type (prednisone) (OR=0.075; 0.011-0.526, p=0.009) was identified as an independent protective factor for NODM. Using a receiver operating characteristic curve, a cutoff cyclosporin A trough concentration of 102.1 ng/mL was identified as a predictive factor of NODM. Univariate logistic regression showed that the incidence of diabetes was significantly higher in patients with baseline glycosylated hemoglobin in non-diabetic range but higher than 5.65% (10.2% vs. 29.2%, p=0.038). One NODM patient (6.7% [1/15]) recovered at 12.7 months after the onset of diabetes mellitus. CONCLUSIONS: We recommend that more attention be paid to patients with baseline glycosylated hemoglobin in non-diabetic range but higher than 5.65% during CKD treatment with CNIs. High trough concentrations of cyclosporin A, particularly those >102.1 ng/mL, contribute to NODM. CNI-associated NODM may be reversible in the treatment of CKD.


Assuntos
Inibidores de Calcineurina/efeitos adversos , Diabetes Mellitus/induzido quimicamente , Insuficiência Renal Crônica/tratamento farmacológico , Inibidores de Calcineurina/sangue , Inibidores de Calcineurina/uso terapêutico , China , Estudos Transversais , Ciclosporina/efeitos adversos , Ciclosporina/sangue , Feminino , Hemoglobinas Glicadas , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Fatores de Risco
11.
Pak J Pharm Sci ; 34(6(Special)): 2441-2445, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35039257

RESUMO

This study aims to explore the nephrotoxicity due to use of combination of cyclosporine A and hormone in the treatment of nephrotic syndrome. From January 2018 to November 2019, 100 patients with primary nephrotic syndrome were divided into experimental and control groups, with 50 patients per group. The experimental group took oral cyclosporine A and prednisone tablets, while the control group received oral cyclosporine A combined with shock therapy. The contents of white blood cells, triglycerides, urine protein and cholesterol in the experimental group were lower than those in the control group, while their albumin content was significantly higher than the control values. Blood concentrations of cyclosporine A were significantly lower in non-nephrotoxic patients than in nephrotoxic patients. The high blood cyclosporine A level in patients (>200ng/mL) may be a factor for inducement of nephrotoxicity. Basal serum creatinine levels in nephrotoxic patients were significantly higher than those in non-nephrotoxic patients. Therefore, high basal creatinine level may be a contributing factor to nephrotoxicity. The combination of cyclosporine A and hormone is effective in the treatment of nephrotic syndrome. Blood cyclosporine A levels greater than 200ng/ml or elevated basal serum creatinine may be the cause of nephrotoxicity.


Assuntos
Ciclosporina/efeitos adversos , Glucocorticoides/efeitos adversos , Imunossupressores/efeitos adversos , Síndrome Nefrótica/tratamento farmacológico , Prednisona/efeitos adversos , Proteinúria/induzido quimicamente , Administração Oral , Adolescente , Adulto , Idoso , Biomarcadores/sangue , Biomarcadores/urina , Creatinina/sangue , Ciclosporina/administração & dosagem , Ciclosporina/sangue , Feminino , Glucocorticoides/administração & dosagem , Humanos , Imunossupressores/administração & dosagem , Imunossupressores/sangue , Lipídeos/sangue , Masculino , Pessoa de Meia-Idade , Síndrome Nefrótica/sangue , Síndrome Nefrótica/diagnóstico , Prednisona/administração & dosagem , Proteinúria/sangue , Proteinúria/diagnóstico , Proteinúria/urina , Medição de Risco , Fatores de Risco , Comprimidos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
12.
Fundam Clin Pharmacol ; 35(2): 446-454, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32734681

RESUMO

Prevention of kidney graft rejection with cyclosporine leads to a large interindividual pharmacokinetic variability. However, food intake is likely to alter cyclosporine pharmacokinetics, and therefore its efficacy. The aim of our study was to evaluate the influence of food and lipid intake on cyclosporine pharmacokinetics. Twenty-four kidney grafted patients treated with Neoral® were included in this prospective monocentric study. In all patients, the pharmacokinetics of cyclosporine was evaluated in two occasions, after meal ('feed') and without meal ('fasting'). At each occasion, blood samples were collected at trough, and 0.5, 1, 2, 3, and 4 h after administration. Cyclosporine pharmacokinetics was described using a Bayesian pharmacokinetic model including two-compartments with first-order transfer and elimination rate constants, and a gamma absorption model. Influence of meal or olive oil, very common in Morocco, was tested as covariates on interoccasion variability parameters. Cyclosporine concentration-time data were satisfactorily described using the Bayesian pharmacokinetic model. Food intake significantly increased volume of distribution and decreased elimination of cyclosporine. The influence of oil intake explained a large part of this effect, suggesting that lipid intake was the main factor of pharmacokinetic variability due to food. This intake resulted in a decrease in area under the concentration curve between two administrations of 14.6%. Food, and especially lipid intake is likely to decrease the exposure to cyclosporine and may therefore lead to a decrease in treatment efficacy. Therefore, to ensure optimal immunosuppression in time, meal composition should remain as steady as possible.


Assuntos
Ciclosporina/farmacocinética , Gorduras na Dieta , Alimentos , Imunossupressores/farmacocinética , Transplante de Rim , Adulto , Idoso , Área Sob a Curva , Ciclosporina/sangue , Feminino , Humanos , Imunossupressores/sangue , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Estudos Prospectivos
13.
Ther Drug Monit ; 42(5): 686-694, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32858576

RESUMO

BACKGROUND: Monitoring immunosuppressant levels, such as mycophenolic acid (MPA), cyclosporin A (CsA), and tacrolimus (TAC), in peripheral blood mononuclear cells (PBMCs) could be useful in organ transplant patients administered individualized therapy. The authors developed a liquid chromatography-tandem mass spectrometry assay technique to simultaneously determine immunosuppressant levels in PBMCs and assess their pharmacokinetics in Chinese renal allograft recipients. METHODS: PBMCs were isolated from the whole blood of 27 Chinese renal transplant patients using Ficoll-Paque Plus solution, and cell number was determined; acetonitrile treatment for protein precipitation, and gradient elution was performed on an Agilent Eclipse XDB-C18 column (3.5 µm, 2.1 × 100 mm) with mobile phase: water and methanol (containing 2 mM ammonium formate); flow rate: 0.3 mL·min. RESULTS: The calibration curves of MPA, CsA, and TAC had a linear range (ng·mL): 0.098-39.2 (r = 0.9987), 0.255-102 (r = 0.9969), and 0.028-11.2 (r = 0.9993), respectively. The extraction effects, matrix effects, and mean relative recovery of these immunosuppressants were 70.4%-93.2%, 72.7%-96.5%, and 90.1%-112.4%, respectively. The within-day and between-day coefficients of variation were <15%. The AUC0-12 of MPA in PBMCs correlated well with those in plasma. The level of MPA, CsA, and TAC in PBMCs might be more stable during dosing interval. CONCLUSIONS: The derived liquid chromatography-tandem mass spectrometry assay is suitable for simultaneously monitoring different immunosuppressants in PBMCs. Pharmacokinetic of MPA, CsA, and TAC displayed considerable interindividual variability. Intracellular monitoring of immunosuppressants may facilitate individualized therapy for renal allograft recipients.


Assuntos
Cromatografia Líquida/métodos , Imunossupressores/sangue , Imunossupressores/farmacocinética , Leucócitos Mononucleares/química , Espectrometria de Massas em Tandem/métodos , Adolescente , Povo Asiático , Ciclosporina/sangue , Ciclosporina/farmacocinética , Ciclosporina/uso terapêutico , Monitoramento de Medicamentos/métodos , Feminino , Humanos , Imunossupressores/uso terapêutico , Rim/metabolismo , Transplante de Rim/métodos , Masculino , Ácido Micofenólico/sangue , Ácido Micofenólico/farmacocinética , Ácido Micofenólico/uso terapêutico , Tacrolimo/sangue , Tacrolimo/farmacocinética , Tacrolimo/uso terapêutico , Transplantados
14.
Ther Drug Monit ; 42(5): 695-701, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32701594

RESUMO

BACKGROUND: Therapeutic drug monitoring of the immunosuppressants tacrolimus, sirolimus, everolimus, and cyclosporine A is effectively performed by analyzing whole-blood samples using liquid chromatography coupled with tandem mass spectrometry. Samples are usually prepared using simple protein precipitation (PPT) with methanol and zinc sulfate (ZnSO4). Significant sample dilution is necessary to obtain clean extracts but may increase the limit of quantification of the method. Salting out-assisted liquid-liquid extraction (SALLE) was explored as a novel sample preparation method for measuring these drugs in blood. METHOD: SALLE, which simply consists of LLE with a water-miscible solvent where phase separation is achieved by adding salt, was used to analyze treated blood samples. RESULTS: SALLE allowed direct injection of a 5-µL extract from the upper solvent phase into a reversed phase LC column, which would not be feasible using standard LLE. Compared with PPT, SALLE provided better extraction efficiencies and more ion enhancement, resulting in limit of quantification of 0.4, 1.4, 0.06, and 0.4 ng/mL for tacrolimus, sirolimus, everolimus, and cyclosporine A, respectively. Full-method validation was performed, including a comparison of results with those of another laboratory. A ≤10% bias was observed for tacrolimus and cyclosporine A, whereas further investigation of that for sirolimus (-12%) and everolimus (-18%) revealed that it was caused by the different calibrators used. CONCLUSIONS: This is the first report of the use of SALLE for the measurement of tacrolimus, sirolimus, everolimus, and cyclosporine A in whole blood. The advantages of SALLE over PPT and conventional LLE would make it an attractive sample preparation method for clinical laboratories.


Assuntos
Ciclosporina/sangue , Monitoramento de Medicamentos/métodos , Everolimo/sangue , Imunossupressores/sangue , Extração Líquido-Líquido/métodos , Sirolimo/sangue , Tacrolimo/sangue , Calibragem , Cromatografia Líquida/métodos , Humanos , Técnicas de Diluição do Indicador , Padrões de Referência , Espectrometria de Massas em Tandem/métodos , Sulfato de Zinco/sangue
15.
Drug Metab Pharmacokinet ; 35(4): 354-360, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32601018

RESUMO

In vitro permeability and in vivo pharmacokinetics of pemafibrate were investigated in human intestinal and animal models untreated or pretreated with cyclosporine A or rifampicin to evaluate any drug interactions. Ratios of basal to apical apparent permeability (Papp) over apical to basal Papp in the presence of pH gradients decreased from 0.37 to 0.080 on rifampicin co-incubation, suggesting active transport of pemafibrate from basal to apical sides in intestinal models. Plasma concentrations of intravenously administered pemafibrate were enhanced moderately in control mice but only marginally in humanized-liver mice by oral pretreatment with rifampicin [an organic anion transporting polypeptide (OATP) 1B1 inhibitor] 1 h before the administration of pemafibrate. In three cynomolgus monkeys genotyped as wild-type OATP1B1 (2 homozygous and 1 heterozygous), oral dosing of cyclosporine A 4 h or rifampicin 1 h before pemafibrate administration significantly increased the areas under the plasma concentration-time curves (AUC) of intravenously administered pemafibrate by 4.9- and 7.4-fold, respectively. Plasma AUC values of three pemafibrate metabolites in cynomolgus monkeys were also increased by cyclosporine A or rifampicin. These results suggested that pemafibrate was actively uptaken in livers and rapidly cleared from plasma in cynomolgus monkeys; this rapid clearance was suppressible by OATP1B1 inhibitors.


Assuntos
Benzoxazóis/sangue , Butiratos/sangue , Ciclosporina/sangue , Hipolipemiantes/sangue , Transportador 1 de Ânion Orgânico Específico do Fígado/genética , Rifampina/sangue , Animais , Benzoxazóis/administração & dosagem , Benzoxazóis/metabolismo , Butiratos/administração & dosagem , Butiratos/metabolismo , Células CACO-2 , Ciclosporina/administração & dosagem , Ciclosporina/metabolismo , Genótipo , Humanos , Hipolipemiantes/administração & dosagem , Hipolipemiantes/metabolismo , Injeções Intravenosas , Transportador 1 de Ânion Orgânico Específico do Fígado/metabolismo , Macaca fascicularis , Masculino , Camundongos , Camundongos Endogâmicos NOD , Camundongos SCID , Rifampina/administração & dosagem , Rifampina/metabolismo
16.
J Clin Pharmacol ; 60(11): 1474-1482, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32557653

RESUMO

Cyclosporine is a primary drug in transplant immunosuppression regimens. It has a narrow therapeutic index and variable pharmacokinetic behavior. This study aimed to develop a population pharmacokinetic model of cyclosporine in Malaysian renal transplant recipients as well as to evaluate the performances of different methodsfor handling missing doses. A total of 2804 concentrationts predose and 2 hours after doses were collected retrospectively from 113 renal transplant patients on cyclosporine in Penang General Hospital. Model structure and pharmacokinetic parameters were estimated using nonlinear mixed-effects modeling software. Missing doses were handled using different methods to evaluate their performance. Covariate analysis was performed using stepwise forward addition (P < .05) followed by backward elimination (P < .001). Prediction-corrected visual predictive check and sampling-importance resampling methods were used to validate the final model. A 1-compartment model with first-order absorption and elimination best fitted the data. All methods to handle missing doses performed well with the missing dose method being superior to other methods and thus was applied in the final model. Cyclosporine clearance (CL/F) was estimated as 15.1 L/h, and volume of distribution (V/F) was 108 L. Postoperative time, sex, and calcium channel blockers were identified as significant covariates on CL/F, whereas sex and cholesterol level were identified as significant covariates on V/F. This is the first population pharmacokinetic model developed in Malaysian renal transplant patients using a large sample with an evaluation of different methods to handle missing doses in less informative conventional therapeutic drug-monitoring data.


Assuntos
Ciclosporina/farmacocinética , Monitoramento de Medicamentos , Imunossupressores/farmacocinética , Modelos Biológicos , Adolescente , Adulto , Idoso , Povo Asiático , Ciclosporina/sangue , Ciclosporina/uso terapêutico , Feminino , Humanos , Imunossupressores/sangue , Imunossupressores/uso terapêutico , Transplante de Rim , Malásia , Masculino , Pessoa de Meia-Idade , Dinâmica não Linear , Estudos Retrospectivos , Adulto Jovem
17.
Transplant Proc ; 52(8): 2503-2506, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32493678

RESUMO

BACKGROUND: Infection remains a serious clinical problem in liver transplant (LTX) recipients. A higher risk of infection is connected with immunosuppression therapy. The aim of the study was to assess the relationships between infections' incidence and concentrations of cyclosporine (CsA) metabolites after LTX. METHODS: Forty-three liver transplant recipients receiving CsA were included in the study. With the use of liquid chromatography combined with tandem mass spectrometry, concentrations of CsA and its metabolites were measured: dihydroxylated cyclosporine metabolites (DiHCsA), trihydroxylated cyclosporine metabolites (TriHCsA), demethylcarboxylated cyclosporine metabolites (DemCarbCsA), AM1, AM9, and AM4N. The study protocol conformed with the Declaration of Helsinki. RESULTS: Patients with a history of Epstein-Barr virus (EBV) infection had higher DiHCsA, TriHCsA, DemCarbCsA, AM1/CsA, DiHCsA/CsA, TriHCsA/CsA i DemCarbCsA/CsA in comparison with group without such infection (P = .049, P = .037, P = .006, P = .018, P = .005, P = .027, and P = .026, respectively). LTX recipients with a history of all viral infections had higher DiHCsA, TriHCsA, DiHCsA/CsA, TriHCsA/CsA than patients without viral infections (P = .013, P = .021, P = .013, and P = .048, respectively). Multivariable analysis showed that AM1, DiHCsA, TriHCsA, DemCarbCsA, AM4N/CsA had positively influence on the incidence of all viral infections (ß = 0.0302, P = .0328; ß = 0.0699, P = .0453; ß = 0.6781, P = .0382; ß = 0.6767, P = .0414; and ß = 0.8307, P = .0267, respectively). In multivariable analysis, patients with a history of all bacterial infections had higher AM1 and higher AM1/CsA in comparison with LTX recipients without such infections (ß = 0.0118, P = .0279; and ß = 0.0099, P = .036, respectively). CONCLUSION: In liver transplant recipients with a history of viral or bacterial infections higher concentrations of CsA metabolites were found. Possibly CsA metabolites could be used to assess the risk of infection in patients after liver transplantation. It should be confirmed in further investigations.


Assuntos
Ciclosporina/sangue , Ciclosporina/uso terapêutico , Imunossupressores/sangue , Imunossupressores/uso terapêutico , Transplante de Fígado , Infecções Bacterianas/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Viroses/epidemiologia
18.
Curr Protoc Toxicol ; 84(1): e92, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32436620

RESUMO

Immunosuppressant medications help suppress the immune system response through inhibition of various checkpoints in the regulatory biochemical pathway. This is useful in prevention of organ rejection in transplantation or in the treatment of autoimmune diseases such as lupus or rheumatoid arthritis. Quantification of immunosuppressive drugs in blood is needed clinically for optimization of treatment and to avoid toxicity or unwanted side effects. Here, we describe a quantitative method to determine the concentration of cyclosprine A, tacrolimus, sirolimus, and everolimus in whole blood. This method has been used for many years clinically to support patient care. © 2020 by John Wiley & Sons, Inc.


Assuntos
Cromatografia Líquida de Alta Pressão , Monitoramento de Medicamentos , Imunossupressores/sangue , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem , Ciclosporina/sangue , Everolimo/sangue , Humanos , Reprodutibilidade dos Testes , Sirolimo/sangue , Tacrolimo/sangue
19.
Transplant Proc ; 52(8): 2394-2402, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32444127

RESUMO

Data binding the expression of Toll-like 4 receptor (TLR4), transplanted kidney (KT) function, and symptomatic CMV infection (CMV+) are scarcely available. OBJECTIVE: To investigate the relationship between TLR4 expression (TLR4ex) in patients who had a relapse of CMV and transplant function. MATERIALS AND METHODS: TLR4ex was measured in peripheral blood mononuclear cells of KT recipients. We compared TLR4ex among 30 CMV+ patients and 87 patients without CMV infection (CMVneg). At the beginning (day 0) TLR4ex, as well as concentrations of cyclosporin A and tacrolimus were determined. All patients, CMV+ and CMVneg patients were divided according to the respective median of TLR4ex into groups of low-TLR4 expression (L-TLR4ex) and high-TLR4 expression (H-TLR4ex). Estimated glomerular filtration rate (EGFR) was assessed on day 0 and after the follow-up (F-up). The magnitudes of EGFR change (ΔEGFR) were evaluated. Stable treatment along the F-up period (median 11.9 months) was applied. RESULTS: TLR4ex of CMV+ in 67% was below median for all patients. For day 0, in CMV+: no link of TLR4ex with EGFR was found; TLR4ex was lower but day 0 EGFR did not differ from H-TLR4ex. In CMVneg, a GFR-TLR4ex link was present. Post F-up. In CMV+ with L-TLR4ex, EGFR declined, with no change in H-TLR4ex. In CMVneg with H-TLR4ex, EGFR increased, with no change in L-TLR4ex. Both regression and receiver operating characteristic curve analyses points out the impact of CMV+ and TLR4ex on eGFR and ΔEGFR. CONCLUSION: In CMV+, low TLR4ex increases the risk of EGFR deterioration. In CMVneg, high TLR4ex raises the chance of EGFR improvement.


Assuntos
Infecções por Citomegalovirus/genética , Rejeição de Enxerto/genética , Transplante de Rim/efeitos adversos , Leucócitos Mononucleares/metabolismo , Receptor 4 Toll-Like/sangue , Adulto , Ciclosporina/sangue , Infecções por Citomegalovirus/virologia , Feminino , Taxa de Filtração Glomerular , Rejeição de Enxerto/virologia , Humanos , Rim/virologia , Masculino , Pessoa de Meia-Idade , Tacrolimo/sangue
20.
Am J Transplant ; 20(7): 1864-1868, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32277555

RESUMO

An ongoing outbreak of pneumonia associated with the severe acute respiratory coronavirus 2 (SARS-CoV-2) started in Wuhan, China, with cases now confirmed in multiple countries. The clinical course of patients remains to be fully characterized, clinical presentation ranges from asymptomatic infection to acute respiratory distress syndrome and acute renal failure, and no pharmacological therapies of proven efficacy yet exist. We report a case of SARS-CoV-2 infection in a renal transplant recipient with excellent outcome. This case states the importance of close monitoring of the concentration of cyclosporine in patients treated with lopinavir/ritonavir; the routine treatment of corticosteroid can be continued. This is a rare report of SARS-CoV-2 infection in a renal transplant recipient. Further data are needed to achieve better understanding of the impact of immunosuppressive therapy on the clinical presentation, severity, and outcome of SARS-CoV-2 infections in solid organ transplant recipients.


Assuntos
Infecções por Coronavirus/complicações , Ciclosporina/sangue , Terapia de Imunossupressão/efeitos adversos , Falência Renal Crônica/cirurgia , Transplante de Rim , Pneumonia Viral/complicações , Transplantados , Corticosteroides/administração & dosagem , Adulto , Betacoronavirus , COVID-19 , China/epidemiologia , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/terapia , Ciclosporina/administração & dosagem , Surtos de Doenças , Combinação de Medicamentos , Humanos , Imunossupressores/administração & dosagem , Falência Renal Crônica/complicações , Doadores Vivos , Lopinavir/administração & dosagem , Masculino , Pandemias , Pneumonia Viral/diagnóstico , Pneumonia Viral/terapia , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Ritonavir/administração & dosagem , SARS-CoV-2 , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...