Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 707
Filtrar
3.
Ophthalmic Plast Reconstr Surg ; 40(5): e154-e156, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38776159

RESUMO

A 54-year-old female noticed a 2-month history of an enlarging left inferomedial orbital rim mass. The patient remembered a pencil injury at approximately 7 years of age. Her complete ophthalmic examination was otherwise unremarkable. She underwent CT orbital imaging, demonstrating a centrally hyperdense lesion along the left inferomedial orbital rim. There was no involvement of the nasolacrimal duct system. The patient underwent an excisional biopsy. The pathology disclosed noncaseating granulomatous inflammation to particulate black material consistent with graphite.


Assuntos
Órbita , Tomografia Computadorizada por Raios X , Humanos , Feminino , Pessoa de Meia-Idade , Órbita/lesões , Órbita/diagnóstico por imagem , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/cirurgia , Corpos Estranhos no Olho/etiologia , Grafite , Biópsia , Doenças Orbitárias/etiologia , Doenças Orbitárias/diagnóstico , Ferimentos Oculares Penetrantes/diagnóstico , Ferimentos Oculares Penetrantes/cirurgia , Ferimentos Oculares Penetrantes/etiologia
4.
BMC Ophthalmol ; 24(1): 80, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38383362

RESUMO

PURPOSE: To compare the efficacy and efficiency of self-assembled intraocular rare earth magnet and forceps in removing intraocular foreign bodies(IOFBs) undergoing 25-gauge(G) pars plana vitrectomy. METHODS: A total of 30 patients with metallic IOFB underwent 25-G PPV were enrolled into this study. Self-assembled intraocular rare earth magnet were used in 15 patients(bar group), and forceps were used in 15 patients(forceps group). Success rate of removing IOFB, time taken to remove IOFB, incidence of IOFB slippage and fall, iatrogenic retinal damages were compared between the two groups. RESULTS: There was no significant difference in success rate of removing IOFBs between the groups(93.3% and 100%, P > 0.99). The median time taken of removing FB was significantly shorter in bar group than in forceps group(112 and 295 s, P = 0.001). None of the patients in bar group had IOFB slippage and fall, or related iatrogenic retinal damage in the process of removal. In forceps group, IOFB slippage and fall during removal were observed in 7 of 15(47.6%) patients, related iatrogenic retinal injuries were recorded in 6 of 15(40.0%) patients, both were significantly higher than bar group(P = 0.003 and P = 0.017, respectively). CONCLUSIONS: Compared with forceps, the assembled intraocular magnet can greatly reduce the possibility of IOFB slippage and fall, prevent related iatrogenic retinal damage, and shorten the time taken to remove IOFB. The assembled intraocular magnet can be an useful tool in removing metallic IOFBs in PPV.


Assuntos
Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Doenças Retinianas , Humanos , Vitrectomia , Imãs , Estudos Retrospectivos , Corpos Estranhos no Olho/etiologia , Corpos Estranhos no Olho/cirurgia , Instrumentos Cirúrgicos , Doenças Retinianas/cirurgia , Doença Iatrogênica , Ferimentos Oculares Penetrantes/etiologia , Ferimentos Oculares Penetrantes/cirurgia
5.
Curr Probl Diagn Radiol ; 53(3): 369-371, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38290902

RESUMO

OBJECTIVE: The purpose of this research is to more precisely quantify the positivity rate for conventional radiographs (CR) of the orbit performed for the purpose of pre-MR screening in patients at risk of having a radio-opaque orbital foreign body (ROFB). METHODS: By review of electronic medical records, we identified 47,237 patients who had undergone orbital CR for clearance of ROFB prior to MRI. The reports from these examinations were manually reviewed, and the examinations with positive findings were re-interpreted by a CAQ-certified head and neck radiologist. The rate of ROFB found in these examinations was reported and compared to historical estimates in the literature. RESULTS: 328 of the 47,237 examinations (0.69 %) were originally interpreted as positive for ROFB. Upon re-review, only 39 of the 47,237 examinations (0.083 %, 95 % CI 0.06 %-0.11 %) contained ROFB that were in locations that posed a risk to ocular or vascular structures or were in an equivocal location. Almost all of the patients with false-positive initial interpretations had been denied MRI. DISCUSSION: The rate of ROFB discovered on clearance CR of the orbits prior to MRI is far less than previously estimated in the radiology literature. More conservative guidelines for MR clearance may be useful to reduce costs, mitigate imaging delays, and avoid unnecessary denial of imaging.


Assuntos
Corpos Estranhos no Olho , Doenças Orbitárias , Humanos , Corpos Estranhos no Olho/diagnóstico por imagem , Corpos Estranhos no Olho/etiologia , Metais , Radiografia , Imageamento por Ressonância Magnética , Órbita/diagnóstico por imagem
6.
Eur J Ophthalmol ; 34(2): NP92-NP97, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37723890

RESUMO

INTRODUCTION: Panuveitis is a serious inflammatory disease. Setae are fibers produced by many insects and plants. Many case reports have described caterpillar and spider fibers entering the eye. These hairs are covered with tiny barbs that help them enter and migrate into the eye tissue, leading to severe inflammation. Normally, they are buried mainly in the conjunctiva and cornea. However, in the present case, they entered the posterior segment of the eye, which is very rare. CASE DESCRIPTION: A female patient presented with a complaint of repeated foreign body sensation, redness, pain, and photophobia in the left eye for 9 years following initial exposure to caterpillars. She visited the doctor in January after aggravation of symptoms. Slit-lamp examination, ultrasound biomicroscopy, ultrasound B-scan, fluorescein angiography, and indocyanine green angiography revealed the presence of a foreign body in the vitreous, which caused discomfort in the patient's left eye and subsequently, panuveitis of the left eye. The symptoms improved significantly after foreign body removal using vitrectomy. Microscopic examination revealed that the foreign body was caterpillar setae. CONCLUSION: Clinicians should be more vigilant about history of contact with caterpillars while examining uveitis that has recurred for many years. Identification of the root cause of the disease can ensure better treatment.


Assuntos
Corpos Estranhos no Olho , Lepidópteros , Pan-Uveíte , Uveíte , Animais , Feminino , Humanos , Sensilas , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/etiologia , Corpos Estranhos no Olho/cirurgia , Pan-Uveíte/diagnóstico , Pan-Uveíte/etiologia , Uveíte/complicações , Córnea
7.
Med Phys ; 51(4): 3124-3129, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38055556

RESUMO

BACKGROUND: Ocular foreign bodies (OFBs) are a relatively common occurrence in ocular injuries, and a severe risk factor for vision disorders. They are notoriously challenging to identify and localize precisely to allow surgical removal, even with the most recent technological advancements. PURPOSE: To compare the efficiency of different imaging methods in detecting and localizing OFBs. METHODS: We conducted a retrospective analysis of the medical records of patients with OFBs, detected by ultrasound biomicroscopy (UBM) and confirmed during surgery. Patients who presented to our medical center between January 2016 and January 2022 and also underwent computed tomography (CT), X ray, and/or ocular B-scan ultrasonography (B-scans) were selected. RESULTS: This study included 134 patients with a history of ocular trauma and OFBs (mean age: 47.25 years, range: 8-78). The mean time interval from injury to UBM examination was 36.31 months (range: 0.2-120 months). Most OFBs were metallic (51.82%) or plant-based (25.37%); 22.39% of them were located in the sclera, 26.87% in the anterior chamber, and 23.88% in the ciliary body and iris. OFBs ranged in size from 0.10 to 6.67 mm (mean: 1.15 ± 1.10 mm). B-scans identified OFBs in 37 of the 119 patients examined (31.09%); CT in 52 of 84 patients (61.90%); and radiography in 29 of 50 patients (58.00%). Univariate and multivariate analyses determined that both CT and radiography showed low detection rates for plant-based versus non-plant-based OFBs (CT: p < 0.001; radiography: p = 0.007), small particles (<1.00 mm vs. >1.00 mm; CT: p = 0.001, radiography: p = 0.024), and with eyeball wall locations (vs. intraocular; CT: p < 0.001, radiography: p = 0.021). Similarly, B-scans were less efficient for plant-based and eyeball wall-located OFBs (both p = 0.001), whereas the difference based on dimensions was not significant (p = 0.118). CONCLUSIONS: CT, radiography, and B-scans showed lower detection rates for plant-based, small, and eyeball wall-located OFBs. Our findings strongly suggest that UBM could be a more adequate imaging modality when such OFBs are suspected.


Assuntos
Corpos Estranhos no Olho , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Corpos Estranhos no Olho/diagnóstico por imagem , Corpos Estranhos no Olho/etiologia , Corpos Estranhos no Olho/cirurgia , Microscopia Acústica , Ultrassonografia , Radiografia
10.
Indian J Ophthalmol ; 71(12): 3620-3625, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37991293

RESUMO

PURPOSE: To assess clinical features, visual outcomes, and setting of mobile battery blast-induced eye injuries in children. METHODS: Retrospective case sheets of children with mobile battery blast injuries were reviewed at a tertiary eye care center from January 2015 to March 2022. We noted the mode of injury, battery status, and clinical presentation and analyzed the treatment outcomes. RESULTS: The study included 14 eyes of 11 patients. Three patients (27%) had bilateral ocular injuries. The most common reasons for the blast were wiring a bulb to the battery or charging the battery with a universal mobile charger, seen in four cases each. Three eyes had closed-globe injuries (CGIs), whereas 11 had open-globe injuries (OGIs). Of the 11 eyes with OGI, four also had a retained intraocular foreign body (IOFB). Only four (36%) eyes having OGI could achieve vision better than 6/60. All three eyes with CGIs developed secondary glaucoma, and two underwent trabeculectomy. However, the visual prognosis was better (>6/36) in eyes with CGI. Overall, mean visual acuity at the final follow-up was improved to 1.41 ± 1.14 logMAR from 2.32 ± 0.76 logMAR at presentation. This was also found to be statistically significant with a P value of 0.02. CONCLUSION: Battery blast-induced ocular injuries, although rare, often lead to poor outcomes. Apart from charging, playing with discarded or damaged batteries was a common reason for battery blasts in our series.


Assuntos
Traumatismos por Explosões , Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Traumatismos Oculares , Humanos , Criança , Traumatismos por Explosões/diagnóstico , Traumatismos por Explosões/epidemiologia , Traumatismos por Explosões/etiologia , Estudos Retrospectivos , Traumatismos Oculares/complicações , Traumatismos Oculares/diagnóstico , Traumatismos Oculares/epidemiologia , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/epidemiologia , Corpos Estranhos no Olho/etiologia , Acuidade Visual , Resultado do Tratamento , Prognóstico , Ferimentos Oculares Penetrantes/diagnóstico , Ferimentos Oculares Penetrantes/epidemiologia , Ferimentos Oculares Penetrantes/etiologia
11.
Mil Med Res ; 10(1): 3, 2023 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-36631894

RESUMO

BACKGROUND: Explosions can produce blast waves, high-speed medium, thermal radiation, and chemical spatter, leading to complex and compound eye injuries. However, few studies have comprehensively investigated the clinical features of different eye injury types or possible risk factors for poor prognosis. METHODS: We retrospectively reviewed all consecutive records of explosive eye injuries (1449 eyes in 1115 inpatients) in 14 tertiary referral hospitals in China over 12 years (between January 2008 and December 2019). Data on demographics, eye injury types, ocular findings, treatments, and factors affecting visual prognosis were extracted from a standardized database of eye injuries and statistically analyzed. RESULTS: Mechanical ocular trauma accounted for 94.00% of explosion-related eye injuries, among which intraocular foreign bodies (IOFBs) resulted in 55.17% of open globe injuries (OGIs) and contusion caused 60.22% of close globe injuries (CGIs). Proliferative vitreous retinopathy (PVR) was more common in perforating (47.06%) and IOFB (26.84%) than in penetrating (8.79%) injuries, and more common with laceration (24.25%) than rupture (9.22%, P < 0.01). However, no difference was observed between rupture and contusion. Ultimately, 9.59% of eyes were removed and the final vision was ≤ 4/200 in 45.82% of patients. Poor presenting vision [odds ratio (OR) = 5.789], full-thickness laceration of the eyeball ≥ 5 mm (OR = 3.665), vitreous hemorrhage (OR = 3.474), IOFB (OR = 3.510), non-mechanical eye injury (NMEI, OR = 2.622, P < 0.001), rupture (OR = 2.362), traumatic optic neuropathy (OR = 2.102), retinal detachment (RD, OR = 2.033), endophthalmitis (OR = 3.281, P < 0.01), contusion (OR = 1.679), ciliary body detachment (OR = 6.592), zone III OGI (OR = 1.940), and PVR (OR = 1.615, P < 0.05) were significant negative predictors for poor visual outcomes. CONCLUSIONS: Explosion ocular trauma has complex mechanisms, with multiple eyes involved and poor prognosis. In lethal level I explosion injuries, eyeball rupture is a serious condition, whereas contusion is more likely to improve. In level II injuries, IOFBs are more harmful than penetrating injuries, and level IV represents burn-related eye injuries. PVR is more associated with penetrating mechanisms than with OGI. Identifying the risk predictors for visual prognosis can guide clinicians in the evaluation and treatment of ocular blast injuries.


Assuntos
Contusões , Substâncias Explosivas , Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Lacerações , Humanos , Prognóstico , Lacerações/complicações , Substâncias Explosivas/efeitos adversos , Estudos Retrospectivos , Ferimentos Oculares Penetrantes/complicações , Ferimentos Oculares Penetrantes/epidemiologia , Acuidade Visual , Corpos Estranhos no Olho/epidemiologia , Corpos Estranhos no Olho/etiologia , Contusões/complicações
12.
Indian J Ophthalmol ; 71(1): 300-302, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36588258

RESUMO

Facial foreign body (FB) is common after trauma, but iatrogenic orbital FB is a rare and unexpected complication of facial FB removal surgery. We present the case of a 43-year-old man with a glass FB in his nose. During the operation, this FB broke into two pieces, and the larger one pierced into the left orbit, close to the eyeball. A three-dimensional (3D) model was made that accurately recreated the shape and position of the FB in the orbit, according to which the FB was removed. 3D-printing technology is a great tool when dealing with complex facial FB.


Assuntos
Corpos Estranhos no Olho , Masculino , Humanos , Adulto , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/etiologia , Corpos Estranhos no Olho/cirurgia , Órbita/diagnóstico por imagem , Órbita/cirurgia , Órbita/lesões , Nariz , Olho , Doença Iatrogênica
13.
Orbit ; 42(3): 306-310, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34753381

RESUMO

Orbital trauma involving high-pressure grease guns is rare and can cause significant morbidity due to retained intraorbital grease. Grease can appear similar to intraorbital air on cross-sectional imaging, and clinicians should have a high index of suspicion for retained intraorbital grease and know how to recognise this. In this case, we will share the clinical and radiological findings as well as management of retained intraorbital grease.


Assuntos
Corpos Estranhos no Olho , Armas de Fogo , Doenças Orbitárias , Humanos , Órbita/diagnóstico por imagem , Órbita/lesões , Incerteza , Corpos Estranhos no Olho/etiologia , Doenças Orbitárias/diagnóstico por imagem , Doenças Orbitárias/etiologia , Hidrocarbonetos
14.
Retina ; 43(12): 2126-2129, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-35333835

RESUMO

PURPOSE: To evaluate the efficiency and safety of using an intraocular foreign body forceps with two nitinol loops at its tip to capture and chop dropped nucleus (DN) during vitrectomy as an alternative method and to evaluate the outcomes and complications of this surgical technique. METHODS: The eyes that underwent 23-gauge vitrectomy with removal of DN using nitinol forceps with a minimum follow-up time of 1 year are included in this study. The efficiency of surgical technique and anatomical and functional results with complications is recorded. RESULTS: Nine patients with a mean age of 73.11 ± 2.15 years were included in this study. The mean time between DN and vitrectomy was 7.67 ± 3.74 (5-14) days. In all eyes, DN was easily chopped and removed with aspiration. Argon laser photocoagulation was performed in 4 eyes (44.44%) during surgery. All eyes were followed up for a mean time of 21.11 ± 12.36 (12-48) months. The mean preoperative best-corrected visual acuity increased significantly during the postoperative follow-up ( P < 0.001). No complications related to the cataract surgery or DN removal were observed. CONCLUSION: Surgical removal of DN with the help of these forceps with nitinol loops is found to be safe and effective in this study. This method avoids ultrasonographic energy and enables 23-gauge vitrectomy without a fragmatome.


Assuntos
Corpos Estranhos no Olho , Complicações Pós-Operatórias , Humanos , Idoso , Resultado do Tratamento , Estudos Retrospectivos , Complicações Pós-Operatórias/etiologia , Vitrectomia/métodos , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/cirurgia , Corpos Estranhos no Olho/etiologia , Instrumentos Cirúrgicos
15.
Pediatr Emerg Care ; 39(3): 130-134, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36099539

RESUMO

OBJECTIVE: The aim of the study is to determine characteristic features of open globe injuries caused by firecrackers among pediatric population. METHODS: In this retrospective cross-sectional chart review, medical records of children with ocular trauma who were hospitalized in Isfahan, Iran, during 2013-2017 were reviewed. We analyzed the collected data before and after propensity score (PS) matching. RESULTS: Of 396 pediatric patients with open globe injury, 22 injuries (5.9%) were caused by firecrackers. Hyphema, iris prolapse, and lens rupture were noted in 15 (68.18%), 10 (45.45%), and 2 (9.09) eyes, respectively. None of patients had endophthalmitis. The mean age of patients in firecracker group was higher and significant (11.86 ± 4.05 in firecracker vs 7.80 ± 4.68 in nonfirecracker, P < 0.001). Furthermore, most boys were in firecracker group (95.5%, P = 0.005). Patients in firecracker group resided more in urban areas (86.4%, P = 0.054) and had more intraocular foreign body (IOFB) in the eyes (40.9%, P < 0.001). After PS matching, patients in firecracker group had higher IOFB ( P = 0.008). In logistic regression models, patients with corneal lacerations had lower odds for long-time admission (≥4 days) than patients with both corneal and scleral lacerations in crude model (odds ratio, 0.35; 95% confidence interval, 0.17-0.69) and adjusted model (odds ratio, 0.37; 95% CI, 0.18 to 0.74). After PS matching, there was no significant association between risk factors and outcomes. CONCLUSIONS: The present study showed several differences between the pediatric open globe injuries caused by firecrackers and other mechanisms of injuries, including the age, sex, living place, presence of IOFB, and length of hospital stay.


Assuntos
Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Traumatismos Oculares , Lacerações , Traumatismo Múltiplo , Masculino , Criança , Humanos , Lacerações/complicações , Estudos Retrospectivos , Irã (Geográfico)/epidemiologia , Estudos Transversais , Ferimentos Oculares Penetrantes/complicações , Ferimentos Oculares Penetrantes/epidemiologia , Traumatismos Oculares/epidemiologia , Traumatismos Oculares/etiologia , Corpos Estranhos no Olho/epidemiologia , Corpos Estranhos no Olho/etiologia , Hospitais
16.
Retina ; 42(5): 973-980, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35471491

RESUMO

PURPOSE: Work-related ocular trauma remains the leading cause of unilateral visual impairment worldwide. Many preventable work-related ocular injuries continue to occur, even at home. This study describes the characteristics, surgical techniques, and prognostic factors of lawn trimmer-related open-globe injuries in eastern Taiwan. METHODS: This was a retrospective, consecutive case series study. Slit-lamp biomicroscopy, dilated fundoscopy, and orbital computed tomography (CT) images were collected. RESULTS: Twenty-six eyes of 26 patients were enrolled in the study. Fifteen patients (57.7%) had an intraocular foreign body (IOFB). The IOFB was metallic in 13 cases and glass and stone in the other 2 cases. Seven IOFBs (46.7%) were retained in the anterior chamber, 7 (46.7%) in the posterior segment, and 1 (6.7%) in the intraconal space. Univariate analysis showed that the presence of IOFB trended toward the development of endophthalmitis; however, this was not statistically significant (hazard ratio, 2.25; 95% confidence interval 0.35-14.61; P = 0.658). Eleven patients had metallic IOFBs noted on CT scans with metal artifacts, whereas two patients had small metallic IOFBs without metal artifacts. One patient had a glass IOFB mimicking metal artifacts on the CT scan. In one case, CT failed to reveal the IOFB, and an intralenticular metallic foreign body was incidentally found intraoperatively. CONCLUSION: Our study provides a broad characterization of lawn trimmer-related open-globe injuries. The informative and diverse findings of IOFBs on CT scans will help clinicians detect and recognize IOFBs more precisely and perform the surgery without causing further damage.


Assuntos
Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/etiologia , Corpos Estranhos no Olho/cirurgia , Ferimentos Oculares Penetrantes/diagnóstico , Ferimentos Oculares Penetrantes/epidemiologia , Ferimentos Oculares Penetrantes/etiologia , Humanos , Estudos Retrospectivos , Taiwan/epidemiologia , Acuidade Visual
19.
Acta Ophthalmol ; 100(1): e71-e76, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34309207

RESUMO

PURPOSE: To compare, in a larger study population, the outcomes of strabismus surgery in patients who either had the scleral explant (EX) retained or removed after surgery for retinal detachment. METHODS: A comparative retrospective study includes data from 2 centres. Surgical outcome, motor success, sensory success, the number of secondary operations for strabismus and complications were compared between the two groups. Motor success was defined as horizontal deviation of ≤6 prism diopters (PD) and vertical deviation of ≤6PD. Sensory success was defined as no diplopia without use of prism. RESULTS: Forty-seven patients were included in the study; 70% had retained the EX and 74% had vertical strabismus. Horizontally, the final alignment was equal between the 2 groups, 4 PD vs.5 PD in the EX removed group. The patients with retained EX were referred with a significant lower mean vertical deviation and had a significant lower post-operative mean vertical deviation of 2 PD vs. 3 PD in the EX-removed group. The rates of motor success (76% vs. 71%) and sensory success (79% vs. 93%) did not differ significantly between the EX-retained and EX-removed groups. No patients underwent more than 2 operations. Two complications occurred in the EX-retained group: a subconjunctival cyst and an exposed EX. In the EX-removed group, 2 patients with retinal re-detachment were found in the follow-up period. CONCLUSION: Good surgical outcomes including high motor and sensory success were obtained regardless of the presence of the EX. Retinal re-detachment was observed in two patients with previously removed EX.


Assuntos
Corpos Estranhos no Olho/cirurgia , Movimentos Oculares/fisiologia , Músculos Oculomotores/cirurgia , Complicações Pós-Operatórias/cirurgia , Descolamento Retiniano/cirurgia , Recurvamento da Esclera/efeitos adversos , Estrabismo/cirurgia , Adolescente , Adulto , Idoso , Remoção de Dispositivo , Corpos Estranhos no Olho/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Reoperação , Estudos Retrospectivos , Esclera , Recurvamento da Esclera/instrumentação , Estrabismo/etiologia , Acuidade Visual , Adulto Jovem
20.
Graefes Arch Clin Exp Ophthalmol ; 260(1): 311-318, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34173880

RESUMO

PURPOSE: Ferromagnetic foreign bodies (FFB) present during magnetic resonance imaging (MRI) explorations can lead to tissue injury due to movement, especially in and around the eyes. Ferromagnetic foreign bodies located in the intraocular area, eyelids, and orbit are thus prohibited from undergoing MRI. The aim of the study was to analyze movement of 4-mm ferromagnetic foreign bodies in MRI in the eye, eyelid, and orbit using computed tomography (CT) scan. METHOD: We developed a porcine model using 12 quarters of fresh porcine heads. Each porcine head included one whole orbit with the ocular globe, orbital fat, muscles, and eyelids. Four-millimeter FFB were implanted in the eye within 2 days post-slaughter, and images were acquired within 5 days post-slaughter. Four-millimeter FFB movement was analyzed after 1.5-Tesla (T) MRI. Four locations were tested: intravitreous, suprachoroidal, intraorbital fat, and intrapalpebral. Movement analysis was assessed using computed tomography (CT) scan. RESULTS: The intravitreous ferromagnetic ball moved 14.0 ± 8.8 mm (p < 0.01), the suprachoroidal ball moved 16.8 ± 5.4 mm (p < 0.01), the intraorbital fat ball moved 5.8 ± 0.9 mm (p > 0.05), and the intrapalpebral ball moved 2.0 ± 0.4 mm (p > 0.05). CONCLUSION: The ex vivo porcine model was able to study FFB movement. The 4-mm ferromagnetic balls moved in intravitreous and in suprachoroidal locations after MRI.


Assuntos
Corpos Estranhos no Olho , Órbita , Animais , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/etiologia , Pálpebras/diagnóstico por imagem , Imageamento por Ressonância Magnética , Órbita/diagnóstico por imagem , Suínos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...