Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.249
Filtrar
1.
J Vis Exp ; (210)2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-39221940

RESUMO

Natural killer cell-derived extracellular vesicles (NK-EVs) are being investigated as cancer biotherapeutics. They possess unique properties as cytotoxic nanovesicles targeting cancer cells and as immunomodulatory communicators. A scalable biomanufacturing workflow enables the production of large quantities of high-purity NK-EVs to meet the pre-clinical and clinical demands. The workflow employs a closed-loop hollow-fiber bioreactor, enabling continuous production of NK-EVs from the NK92-MI cell line under serum-free, xeno-free, feeder-free, and antibiotic-free conditions in compliance with Good Manufacturing Practices standards. This protocol-driven study outlines the biomanufacturing workflow for isolating NK-EVs using size-exclusion chromatography, ultrafiltration, and filter-based sterilization. Essential NK-EV product characterization is performed via nanoparticle tracking analysis, and their functionality is assessed through a validated cell viability-based potency assay against cancer cells. This scalable biomanufacturing process holds significant potential to advance the clinical translation of NK-EV-based cancer biotherapeutics by adhering to best practices and ensuring reproducibility.


Assuntos
Vesículas Extracelulares , Células Matadoras Naturais , Humanos , Vesículas Extracelulares/química , Fluxo de Trabalho , Reatores Biológicos , Neoplasias/patologia , Cromatografia em Gel/métodos , Linhagem Celular Tumoral
2.
Int J Mol Sci ; 25(15)2024 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-39126063

RESUMO

Small extracellular vesicles (EVs) play a pivotal role in intercellular communication across various physiological and pathological contexts. Despite their growing significance as disease biomarkers and therapeutic targets in biomedical research, the lack of reliable isolation techniques remains challenging. This study characterizes vesicles that were isolated from conditioned culture media (CCM) sourced from three myeloma cell lines (MM.1S, ANBL-6, and ALMC-1), and from the plasma of healthy donors and multiple myeloma patients. We compared the efficacy, reproducibility, and specificity of isolating small EVs using sucrose cushion ultracentrifugation (sUC) vs. ultrafiltration combined with size-exclusion chromatography (UF-SEC). Our results demonstrate that UF-SEC emerges as a more practical, efficient, and consistent method for EV isolation, outperforming sUC in the yield of EV recovery and exhibiting lower variability. Additionally, the comparison of EV characteristics among the three myeloma cell lines revealed distinct biomarker profiles. Finally, our results suggest that HBS associated with Tween 20 improves EV recovery and preservation over PBS. Standardization of small EV isolation methods is imperative, and our comparative evaluation represents a significant step toward achieving this goal.


Assuntos
Cromatografia em Gel , Vesículas Extracelulares , Mieloma Múltiplo , Sacarose , Ultracentrifugação , Mieloma Múltiplo/patologia , Humanos , Vesículas Extracelulares/metabolismo , Vesículas Extracelulares/química , Ultracentrifugação/métodos , Cromatografia em Gel/métodos , Linhagem Celular Tumoral , Reprodutibilidade dos Testes , Meios de Cultivo Condicionados/química
3.
J Chromatogr A ; 1733: 465263, 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39154495

RESUMO

This study investigates the impact of 2-methyl imidazolium dihydrogen phosphate (2-MIDHP) on monoclonal antibody (mAb) aggregation during the Protein A purification stage, at a low pH (pH 3.0), and the viral inactivation phase. Size-exclusion high-performance liquid chromatography (SE-HPLC) and dynamic light scattering (DLS) were used to assess the mAb aggregation. Additionally, the influence of 2-MIDHP on mAb recovery, host cell protein (HCP) clearance, and Protein A leaching was investigated. Thermal stability of mAb, eluted in buffers containing 5 % to 25 % 2-MIDHP was analysed, using differential scanning calorimetry (DSC). Structural insights were obtained via circular dichroism (CD) and fluorescence spectroscopy. Our findings indicated that 2-MIDHP exerted a concentration-dependent protective effect against mAb aggregation, at the pH of 3.0. As the concentration of 2-MIDHP was increased from 0 % to 25 %, the aggregation was significantly reduced from 3.8 ± 0.01 % to 0.56 ± 0.002 %, as analysed by SE-HPLC. Addition of 2-MIDHP did not significantly impact the mAb recovery, HCP clearance, or Protein A leaching. DSC data supported these results, with higher 2-MIDHP concentrations leading to increased melting temperatures of mAb. CD and fluorescence spectroscopy revealed no significant changes in the secondary structure or aromatic residue environment in 2-MIDHP-treated samples, despite the observed reduction in aggregation. The results suggested that 2-MIDHP mitigated mAb aggregation during Protein A purification, possibly by stabilizing the protein structure under acidic stress conditions. These findings offer valuable insights for improving the robustness of mAb purification processes, enhancing product quality and yield.


Assuntos
Anticorpos Monoclonais , Imidazóis , Estabilidade Proteica , Proteína Estafilocócica A , Anticorpos Monoclonais/química , Anticorpos Monoclonais/isolamento & purificação , Imidazóis/química , Proteína Estafilocócica A/química , Animais , Cromatografia Líquida de Alta Pressão/métodos , Concentração de Íons de Hidrogênio , Células CHO , Cricetulus , Dicroísmo Circular , Cromatografia em Gel/métodos , Cromatografia de Afinidade/métodos , Varredura Diferencial de Calorimetria , Espectrometria de Fluorescência , Agregados Proteicos
4.
J Chromatogr A ; 1733: 465242, 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39154497

RESUMO

Sulodexide, a heparinoid medicine, is wildly used in clinic for prophylaxis and treatment of thromboembolic diseases and diabetic nephropathy. Despite its widespread use, the structure of Sulodexide remains poorly understood. It consists of various polysaccharides characterized by differing sugar compositions, linkages, and sulfonation patterns, yet they share common features such as strong hydrophilicity, high native charges, and considerable polydispersity, posing significant challenges for conventional chromatographic and online mass spectrometry (MS) characterization. In this work, a novel analytical method combining multiple-heart cut 2D-LC and in-source acid-induced dissociation (inAID) MS was developed. Three polysaccharides in Sulodexide were separated by high efficient strong-anion-exchange chromatography, followed by desalting with the second dimensional size-exclusion chromatography before MS. A novel MS strategy employing inAID technique was utilized for online analysis, leading to the initial identification of Sulodexide polysaccharide components. The results were validated through disaccharide composition analysis of those three polysaccharide components after offline preparation. This advanced strategy, merging various techniques, enable a comprehensive structural elucidation of such complex drugs and provides a viable tool for potential routine analysis of complex biomolecules.


Assuntos
Glicosaminoglicanos , Glicosaminoglicanos/química , Glicosaminoglicanos/análise , Espectrometria de Massas/métodos , Cromatografia em Gel/métodos , Cromatografia por Troca Iônica/métodos
5.
J Chromatogr A ; 1733: 465285, 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39173502

RESUMO

Nucleic acid duplexes are typically analyzed in non-denaturing conditions. Melting temperature (Tm) is the property used to measure duplex stability; however, it is not known how the chromatographic conditions and mobile phase composition affect the duplex stability. We employed differential scanning calorimetry (DSC) method to measure the melting temperature of chemically modified silencing RNA duplex (21 base pairs, 0.15 mM duplex concentration) in mobile phases commonly used in reversed-phase, ion-pair reversed-phase, size exclusion and hydrophilic interaction chromatography. We investigated mobile phases consisting of ammonium acetate, alkylammonium ion-pairing reagents, alkali-ion chlorides, magnesium chloride, and additives including methanol, ethanol, acetonitrile and hexafluoroisopropanol. Increasing buffer concentration enhanced the duplex stability (Tm was 67.1 - 78.2 °C for 10-100 mM [Na+] concentration). The melting temperature decreases with the increase in cation size (70.2 °C in 10 mM [Li+], 68.1 °C in 10 mM [NH4+], 65.6 °C in 10 mM [Cs+], and 56.6 °C in 10 mM [triethylammonium+] solutions). Inclusion of 20 % of organic solvent in buffer reduced the melting temperature by 1-3 °C, and denaturation power increases in the order MeOH

Assuntos
Varredura Diferencial de Calorimetria , RNA Interferente Pequeno , RNA Interferente Pequeno/química , Estabilidade de RNA , Cromatografia de Fase Reversa/métodos , Acetonitrilas/química , Acetatos/química , Metanol/química , Interações Hidrofóbicas e Hidrofílicas , Solventes/química , Propanóis/química , Cromatografia Líquida/métodos , Etanol/química , Temperatura de Transição , Cromatografia em Gel/métodos , Cloreto de Magnésio/química , Hidrocarbonetos Fluorados
6.
Artigo em Inglês | MEDLINE | ID: mdl-38996753

RESUMO

Metalloproteins binding with trace elements play a crucial role in biological processes and on the contrary, those binding with exogenous heavy metals have adverse effects. However, the methods for rapid, high sensitivity and simultaneous analysis of these metalloproteins are still lacking. In this study, a fast method for simultaneously determination of both essential and toxic metal-containing proteins was developed by coupling size exclusion chromatography (SEC) with inductively coupled plasma tandem mass spectrometry (ICP-MS/MS). After optimization of the separation and detection conditions, seven metalloproteins with different molecular weight (from 16.0 to 443.0 kDa) were successfully separated within 10 min and the proteins containing iron (Fe), copper (Cu), zinc (Zn), iodine (I) and lead (Pb) elements could be simultaneously detected with the use of oxygen as the collision gas in ICP-MS/MS. Accordingly, the linear relationship between log molecular weight and retention time was established to estimate the molecular weight of unknown proteins. Thus, the trace metal and toxic metal containing proteins could be detected in a single run with high sensitivity (detection limits in the range of 0.0020-2.5 µg/mL) and good repeatability (relative standard deviations lower than 4.5 %). This method was then successfully used to analyze metal (e.g., Pb, Zn, Cu and Fe) binding proteins in the blood of Pb-intoxicated patients, and the results showed a negative correlation between the contents of zinc and lead binding proteins, which was identified to contain hemoglobin subunit. In summary, this work provided a rapid and sensitive tool for screening metal containing proteins in large number of biological samples.


Assuntos
Cromatografia em Gel , Limite de Detecção , Metaloproteínas , Espectrometria de Massas em Tandem , Cromatografia em Gel/métodos , Espectrometria de Massas em Tandem/métodos , Humanos , Reprodutibilidade dos Testes , Metaloproteínas/sangue , Metaloproteínas/química , Metaloproteínas/análise , Modelos Lineares , Metais Pesados/sangue , Metais Pesados/análise , Metais Pesados/química , Animais
7.
Anal Biochem ; 694: 115601, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38971527

RESUMO

The measurement of free hemoglobin (free Hb) in blood is crucial for assessing the risk of organ damage in patients with hemolytic diseases. However, the colorimetric method, commonly used in clinical practice, does not distinguish between free Hb and the hemoglobin-haptoglobin complex (Hb-Hp) in the blood, instead reflecting the total Hb level. Although size-exclusion high-performance liquid chromatography (SEC-HPLC) can specifically measure free Hb, its clinical use is limited by long assay times. Here, we developed a novel assay method for the rapid quantification of free Hb in serum, distinguishing it from Hb-Hp, using a latex agglutination immunoturbidimetric assay (LATIA). This method could be used to measure free Hb in sera in the range of 1-100 µg/mL in approximately 15 min using an automatic biochemistry analyzer. Using Hb-spiked serum samples from healthy adults, there was a high correlation with Hb levels determined using the newly developed method and SEC-HPLC, indicating a high specificity for free Hb. This novel assay can be used to monitor levels of free Hb in patients with various hemolytic diseases and to design therapeutic strategies based on measured values. However, further studies are required to assess its clinical performance.


Assuntos
Haptoglobinas , Hemoglobinas , Humanos , Haptoglobinas/análise , Hemoglobinas/análise , Cromatografia Líquida de Alta Pressão/métodos , Imunoturbidimetria/métodos , Adulto , Testes de Fixação do Látex/métodos , Cromatografia em Gel/métodos
8.
Anal Chem ; 96(29): 11716-11724, 2024 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-38986034

RESUMO

Assessment of critical quality attributes (CQAs) is an important aspect during the development of therapeutic monoclonal antibodies (mAbs). Attributes that affect either the target binding or Fc receptor engagement may have direct impacts on the drug safety and efficacy and thus are considered as CQAs. Native size exclusion chromatography (SEC)-based competitive binding assay has recently been reported and demonstrated significant benefits compared to conventional approaches for CQA identification, owing to its faster turn-around and higher multiplexity. Expanding on the similar concept, we report the development of a novel affinity-resolved size exclusion chromatography-mass spectrometry (AR-SEC-MS) method for rapid CQA evaluation in therapeutic mAbs. This method features wide applicability, fast turn-around, high multiplexity, and easy implementation. Using the well-studied Fc gamma receptor III-A (FcγRIIIa) and Fc interaction as a model system, the effectiveness of this method in studying the attribute-and-function relationship was demonstrated. Further, two case studies were detailed to showcase the application of this method in assessing CQAs related to antibody target binding, which included unusual N-linked glycosylation in a bispecific antibody and Met oxidation in a monospecific antibody, both occurring within the complementarity-determining regions (CDRs).


Assuntos
Anticorpos Monoclonais , Cromatografia em Gel , Espectrometria de Massas , Anticorpos Monoclonais/química , Cromatografia em Gel/métodos , Espectrometria de Massas/métodos , Humanos , Receptores de IgG/metabolismo , Cromatografia de Afinidade/métodos
9.
Anal Bioanal Chem ; 416(23): 5097-5109, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39046506

RESUMO

Iron plays vital roles in important biological processes in fish, but can be toxic in high concentrations. The information on metalloproteins that participate in maintenance of Fe homeostasis in an esocid fish, the northern pike, as an important freshwater bioindicator species, are rather scarce. The aim of this study was to identify main cytosolic constituents that sequester Fe in the northern pike liver. The method applied consisted of two-dimensional HPLC separation of Fe-binding biomolecules, based on anion-exchange followed by size-exclusion fractionation. Apparent molecular masses of two main Fe-metalloproteins isolated by this procedure were ~360 kDa and ~50 kDa, with the former having more acidic pI, and indicated presence of ferritin and hemoglobin, respectively. MALDI-TOF-MS provided confirmation of ferritin subunit with a m/z peak at 20.65 kDa, and hemoglobin with spectra containing main m/z peak at 16.1 kDa, and smaller peaks at 32.1, 48.2, and 7.95 kDa (single-charged Hb-monomer, dimer, and trimer, and double-charged monomer, respectively). LC-MS/MS with subsequent MASCOT database search confirmed the presence of Hb-ß subunits and pointed to close relation between esocid and salmonid fishes. Further efforts should be directed towards optimization of the conditions for metalloprotein analysis by mass spectrometry, to extend the knowledge on intracellular metal-handling mechanisms.


Assuntos
Esocidae , Ferro , Fígado , Animais , Fígado/química , Fígado/metabolismo , Ferro/análise , Ferro/metabolismo , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Cromatografia Líquida de Alta Pressão/métodos , Hemoglobinas/metabolismo , Hemoglobinas/análise , Hemoglobinas/química , Ferritinas/química , Ferritinas/metabolismo , Espectrometria de Massas em Tandem/métodos , Cromatografia em Gel/métodos , Proteínas de Peixes/química , Proteínas de Peixes/metabolismo , Proteínas de Peixes/isolamento & purificação , Proteínas de Peixes/análise
10.
Anal Methods ; 16(32): 5536-5544, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39046449

RESUMO

Extracellular vesicles (EVs) have attracted great interest due to their great potential in disease diagnosis and therapy. The separation of EVs from complex biofluids with high purity is essential for the accurate analysis of EVs. Despite various methods, there is still no consensus on the best method for high-quality EV isolation and reliable mass production. Therefore, it is important to offer a standardized method for characterizing the properties (size distribution, particle concentration and purity) of EV preparations from different isolation methods. Herein, we employed a NanoCoulter Counter based on the resistive pulse sensing (RPS) strategy that enabled multi-parameter analysis of single EVs to compare the quality and efficiency of different EV isolation techniques including traditional differential ultracentrifugation, ultrafiltration, size exclusion chromatography, membrane affinity binding and polymer precipitation. The data revealed that the NanoCoulter Counter based on the RPS strategy was reliable and effective for the characterization of EVs. The results suggested that although higher particle concentrations were observed in three commercial isolation kits and ultrafiltration, traditional differential ultracentrifugation showed the highest purity. In conclusion, our results from the NanoCoulter Counter provided reliable evidence for the assessment of different EV isolation methods, which contributed to the development of EV-based disease biomarkers and treatments.


Assuntos
Cromatografia em Gel , Vesículas Extracelulares , Ultracentrifugação , Ultrafiltração , Vesículas Extracelulares/química , Humanos , Ultracentrifugação/métodos , Ultrafiltração/métodos , Cromatografia em Gel/métodos , Tamanho da Partícula
11.
Protein Expr Purif ; 223: 106544, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38972616

RESUMO

Size-exclusion chromatography-high performance liquid chromatography (SEC-HPLC) is an analytical method routinely used for assessing aggregation content in protein samples. As SEC-HPLC separates analytes based on their hydrodynamic radius, it generally lacks the capability of differentiating species that are similar in size. Recently while purifying a bispecific antibody (bsAb), we noticed that SEC-HPLC can provide certain degree of resolution between the target bsAb and a disulfide scrambled form, although these two species were identical in molecular weight. In seeing the unexpected potential of SEC-HPLC at resolving species with similar size, we further tested Zenix SEC-300, a mixed-mode SEC-HPLC column from Sepax, which was reported to be capable of separating protein analytes based on other factors besides size. The Zenix column indeed provided resolution much better than the regular SEC-HPLC column. Upon further optimization, the Zenix column allowed close to baseline separation of the correctly folded and the disulfide scrambled species. The current study, as a complement to the previous reports, further demonstrates that mix-mode SEC-HPLC is capable of separating protein analytes that are close in size but are different in conformation and/or surface characteristics.


Assuntos
Anticorpos Biespecíficos , Cromatografia em Gel , Dissulfetos , Anticorpos Biespecíficos/isolamento & purificação , Anticorpos Biespecíficos/química , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia em Gel/métodos , Dissulfetos/química , Humanos , Animais
12.
Int J Biol Macromol ; 277(Pt 2): 134236, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39079564

RESUMO

Natural polysaccharides exhibit a wide range of biological activities, which are closely related to their structural characteristics, including their molecular weight distribution, size, monosaccharide composition, glycosidic bond types and spatial conformation, etc. Size exclusion chromatography (SEC) and asymmetrical flow field-flow fractionation (AF4), as two potent separation techniques, both harbor potential for continuous development and enhancement. This manuscript reviewed the fundamental principles and separation applications of SEC and AF4. The structural information and spatial conformation of polysaccharides can be obtained using SEC or AF4 coupled with multiple detectors. In addition, this manuscript elaborates in detail on the shear degradation of samples such as polysaccharides separated by SEC. In addition, the abnormal elution that occurs during the application of the two methods is also discussed. Both SEC and AF4 possess considerable potential for ongoing development and refinement, thereby offering increased possibilities and opportunities for polysaccharide separation and characterization.


Assuntos
Cromatografia em Gel , Fracionamento por Campo e Fluxo , Peso Molecular , Polissacarídeos , Polissacarídeos/química , Polissacarídeos/isolamento & purificação , Cromatografia em Gel/métodos , Fracionamento por Campo e Fluxo/métodos , Monossacarídeos/química , Monossacarídeos/análise
13.
BMC Res Notes ; 17(1): 202, 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39044286

RESUMO

OBJECTIVE: Extracellular vesicles (EVs) have been shown to play a critical role in promoting tumorigenesis. As EV research grows, it is of importance to have standardization of isolation, quality control, characterization and validation methods across studies along with reliable references to explore troubleshooting solutions. Therefore, our objective with this Research Note was to isolate EVs from multiple breast cancer cell lines and to describe and perform protocols for validation as outlined by the list of minimal information for studies of EVs (MISEV) from the International Society for Extracellular Vesicles. RESULTS: To isolate EVs, two techniques were employed: ultracentrifugation and size exclusion chromatography. Ultracentrifugation yielded better recovery of EVs in our hands and was therefore used for further validation. In order to satisfy the MISEV requirements, protein quantification, immunoblotting of positive (CD9, CD63, TSG101) and negative (TGFß1, ß-tubulin) markers, nanoflow cytometry and electron microscopy was performed. With these experiments, we demonstrate that yield of validated EVs varied between different breast cancer cell lines. Protocols were optimized to accommodate for low levels of EVs, and various technical and troubleshooting suggestions are included for potential application to other cell types that may provide benefit to investigators interested in future EV studies.


Assuntos
Neoplasias da Mama , Vesículas Extracelulares , Humanos , Vesículas Extracelulares/metabolismo , Neoplasias da Mama/patologia , Feminino , Linhagem Celular Tumoral , Ultracentrifugação/métodos , Controle de Qualidade , Cromatografia em Gel/métodos , Complexos Endossomais de Distribuição Requeridos para Transporte/metabolismo , Tetraspanina 29/metabolismo , Tetraspanina 30/metabolismo , Proteínas de Ligação a DNA , Fatores de Transcrição
14.
PLoS One ; 19(6): e0305418, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38889139

RESUMO

Small extracellular vesicles (sEVs) are cell-released vesicles ranging from 30-150nm in size. They have garnered increasing attention because of their potential for both the diagnosis and treatment of disease. The diversity of sEVs derives from their biological composition and cargo content. Currently, the isolation of sEV subpopulations is primarily based on bio-physical and affinity-based approaches. Since a standardized definition for sEV subpopulations is yet to be fully established, it is important to further investigate the correlation between the biomolecular composition of sEVs and their physical properties. In this study, we employed a platform combining single-vesicle surface-enhanced Raman spectroscopy (SERS) and machine learning to examine individual sEVs isolated by size-exclusion chromatography (SEC). The biomolecular composition of each vesicle examined was reflected by its corresponding SERS spectral features (biomolecular "fingerprints"), with their roots in the composition of their collective Raman-active bonds. Origins of the SERS spectral features were validated through a comparative analysis between SERS and mass spectrometry (MS). SERS fingerprinting of individual vesicles was effective in overcoming the challenges posed by EV population averaging, allowing for the possibility of analyzing the variations in biomolecular composition between the vesicles of similar and/or different sizes. Using this approach, we uncovered that each of the size-based fractions of sEVs contained particles with predominantly similar SERS spectral features. Indeed, more than 84% of the vesicles residing within a particular group were clearly distinguishable from that of the other EV sub-populations, despite some spectral variations within each sub-population. Our results suggest the possibility that size-based EV fractionation methods produce samples where similarly eluted sEVs are correlated with their respective biochemical contents, as reflected by their SERS spectra. Our findings therefore highlight the possibility that the biogenesis and respective biological functionalities of the various sEV fractions may be inherently different.


Assuntos
Vesículas Extracelulares , Análise Espectral Raman , Análise Espectral Raman/métodos , Vesículas Extracelulares/química , Vesículas Extracelulares/metabolismo , Humanos , Cromatografia em Gel/métodos , Aprendizado de Máquina , Espectrometria de Massas/métodos
15.
Int J Mol Sci ; 25(11)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38891833

RESUMO

In the last few years, several studies have emphasized the existence of injury-specific EV "barcodes" that could have significant importance for the precise diagnosis of different organ injuries in polytrauma patients. To expand the research potential of the NTF (network trauma research) biobank of polytraumatized patients, the NTF research group decided to further establish a biobank for EVs. However, until now, the protocols for the isolation, characterization, and storage of EVs for biobank purposes have not been conceptualized. Plasma and serum samples from healthy volunteers (n = 10) were used. Three EV isolation methods of high relevance for the work with patients' samples (ultracentrifugation, size exclusion chromatography, and immune magnetic bead-based isolation) were compared. EVs were quantified using nanoparticle tracking analysis, EV proteins, and miRNAs. The effects of different isolation solutions; the long storage of samples (up to 3 years); and the sensibility of EVs to serial freezing-thawing cycles and different storage conditions (RT, 4/-20/-80 °C, dry ice) were evaluated. The SEC isolation method was considered the most suitable for EV biobanking. We did not find any difference in the quantity of EVs between serum and plasma-EVs. The importance of particle-free PBS as an isolation solution was confirmed. Plasma that has been frozen for a long time can also be used as a source of EVs. Serial freezing-thawing cycles were found to affect the mean size of EVs but not their amount. The storage of EV samples for 5 days on dry ice significantly reduced the EV protein concentration.


Assuntos
Bancos de Espécimes Biológicos , Vesículas Extracelulares , Traumatismo Múltiplo , Humanos , Vesículas Extracelulares/metabolismo , Traumatismo Múltiplo/metabolismo , Traumatismo Múltiplo/sangue , Manejo de Espécimes/métodos , Cromatografia em Gel/métodos , Masculino , Ultracentrifugação/métodos , MicroRNAs/sangue , MicroRNAs/genética , Adulto , Feminino
16.
Int J Mol Sci ; 25(11)2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38892442

RESUMO

Biopharmaceutical products, in particular messenger ribonucleic acid (mRNA), have the potential to dramatically improve the quality of life for patients suffering from respiratory and infectious diseases, rare genetic disorders, and cancer. However, the quality and safety of such products are particularly critical for patients and require close scrutiny. Key product-related impurities, such as fragments and aggregates, among others, can significantly reduce the efficacy of mRNA therapies. In the present work, the possibilities offered by size exclusion chromatography (SEC) for the characterization of mRNA samples were explored using state-of-the-art ultra-wide pore columns with average pore diameters of 1000 and 2500 Å. Our investigation shows that a column with 1000 Å pores proved to be optimal for the analysis of mRNA products, whatever the size between 500 and 5000 nucleotides (nt). We also studied the influence of mobile phase composition and found that the addition of 10 mM magnesium chloride (MgCl2) can be beneficial in improving the resolution and recovery of large size variants for some mRNA samples. We demonstrate that caution should be exercised when increasing column length or decreasing the flow rate. While these adjustments slightly improve resolution, they also lead to an apparent increase in the amount of low-molecular-weight species (LMWS) and monomer peak tailing, which can be attributed to the prolonged residence time inside the column. Finally, our optimal SEC method has been successfully applied to a wide range of mRNA products, ranging from 1000 to 4500 nt in length, as well as mRNA from different suppliers and stressed/unstressed samples.


Assuntos
Cromatografia em Gel , RNA Mensageiro , RNA Mensageiro/genética , RNA Mensageiro/química , Cromatografia em Gel/métodos , Humanos , Porosidade , Peso Molecular , Cloreto de Magnésio/química
17.
Methods Mol Biol ; 2810: 329-353, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38926289

RESUMO

In the recent years, there has been a rapid development of new technologies and strategies when it comes to protein purification and quality control (QC), but the basic technologies for these processes go back a long way, with many improvements over the past few decades. The purpose of this chapter is to review these approaches, as well as some other topics such as the advantages and disadvantages of various purification methods for intracellular or extracellular proteins, the most effective and widely used genetically engineered affinity tags, solubility-enhancing tags, and specific proteases for removal of nontarget sequences. Affinity chromatography (AC), like Protein A or G resins for the recovery of antibodies or Fc fusion proteins or immobilized metals for the recovery of histidine-tagged proteins, will be discussed along with other conventional chromatography techniques: ion exchange (IEC), hydrophobic exchange (HEC), mixed mode (MMC), size exclusion (SEC), and ultrafiltration (UF) systems. How to select and combine these different technologies for the purification of any given protein and the minimal criteria for QC characterization of the purity, homogeneity, identity, and integrity of the final product will be presented.


Assuntos
Cromatografia de Afinidade , Controle de Qualidade , Proteínas Recombinantes , Proteínas Recombinantes/isolamento & purificação , Proteínas Recombinantes/genética , Animais , Humanos , Cromatografia de Afinidade/métodos , Cromatografia por Troca Iônica/métodos , Ultrafiltração/métodos , Cromatografia em Gel/métodos
18.
J Chromatogr A ; 1730: 465051, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-38852241

RESUMO

Size exclusion chromatography (SEC) is unique among chromatographic methods as it allows separation of non-retained analytes. However, such mechanism often put an analytical scientist in front of relatively poorly resolved set of peaks that may have strikingly different abundance. The description of such chromatograms needs a particular approach to accurately capture the overall quality of separation. Consequently, use of a single parameter description may not be accurate enough and therefore we introduce a dimensionless separation quality factor, which is based on five SEC specific measures (peak-to-valley, elution window width, peak widths, peak-positioning and recovery). Combining several factors allowed detailed differentiation of various simulated separations, clearly correlating column characteristics with specific contributions to separation quality whether they concern a single peak pair or entire peak landscape. The method could be further elaborated by the addition of normalized priority weighting allowing for flexible quality quantification of a relevant portion of real-life nucleic acid separation on different columns. With growing complexity of biotherapeutics to be separated, such a term is predicted to be a useful response function for purposes of factorial method optimization.


Assuntos
Cromatografia em Gel , Cromatografia em Gel/métodos , Ácidos Nucleicos/isolamento & purificação , Ácidos Nucleicos/análise , Ácidos Nucleicos/química
19.
Proteomics ; 24(16): e2400025, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38895962

RESUMO

Extracellular vesicles (EVs) carry diverse biomolecules derived from their parental cells, making their components excellent biomarker candidates. However, purifying EVs is a major hurdle in biomarker discovery since current methods require large amounts of samples, are time-consuming and typically have poor reproducibility. Here we describe a simple, fast, and sensitive EV fractionation method using size exclusion chromatography (SEC) on a fast protein liquid chromatography (FPLC) system. Our method uses a Superose 6 Increase 5/150, which has a bed volume of 2.9 mL. The FPLC system and small column size enable reproducible separation of only 50 µL of human plasma in 15 min. To demonstrate the utility of our method, we used longitudinal samples from a group of individuals who underwent intense exercise. A total of 838 proteins were identified, of which, 261 were previously characterized as EV proteins, including classical markers, such as cluster of differentiation (CD)9 and CD81. Quantitative analysis showed low technical variability with correlation coefficients greater than 0.9 between replicates. The analysis captured differences in relevant EV proteins involved in response to physical activity. Our method enables fast and sensitive fractionation of plasma EVs with low variability, which will facilitate biomarker studies in large clinical cohorts.


Assuntos
Cromatografia em Gel , Vesículas Extracelulares , Proteômica , Humanos , Vesículas Extracelulares/química , Vesículas Extracelulares/metabolismo , Cromatografia em Gel/métodos , Proteômica/métodos , Biomarcadores/sangue
20.
Artigo em Inglês | MEDLINE | ID: mdl-38823148

RESUMO

The development and optimization of Antibody-Drug Conjugates (ADCs) hinge on enhanced analytical and bioanalytical characterization, particularly in assessing critical quality attributes (CQAs). The ADC's potency is largely determined by the average number of drugs attached to the monoclonal antibody (mAb), known as the drug-to-antibody ratio (DAR). Furthermore, the drug load distribution (DLD) influences the therapeutic window of the ADC, defining the range of dosages effective in treating diseases without causing toxic effects. Among CQAs, DAR and DLD are vital; their control is essential for ensuring manufacturing consistency and product quality. Typically, hydrophobic interaction chromatography (HIC) or reversed-phase liquid chromatography (RPLC) with UV detector have been used to quantitate DAR and DLD in quality control (QC) environment. Recently, Native size-exclusion chromatography-mass spectrometry (nSEC-MS) proves the potential as a platformable quantitative method for characterizing DAR and DLD across various cysteine-linked ADCs in research or early preclinical development. In this work, we established and assessed a streamlined nSEC-MS workflow with a benchtop LC-MS platform, to quantitatively monitor DAR and DLD of different chemotype and drug load level cysteine-linked ADCs. Moreover, to deploy this workflow in QC environment, complete method validation was conducted in three independent laboratories, adhering to the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH) Q2(R1) guidelines. The results met the predefined analytical target profile (ATP) and performance criteria, encompassing specificity/selectivity, accuracy, precision, linearity, range, quantification/detection limit, and robustness. Finally, the method validation design offers a reference for other nSEC-MS methods that are potentially used to determine the DAR and DLD on cysteine-linker ADCs. To the best of our knowledge, this study is the first reported systematic validation of the nSEC-MS method for detecting DAR and DLD. The results indicated that the co-validated nSEC-MS workflow is suitable for DAR and DLD routine analysis in ADC quality control, release, and stability testing.


Assuntos
Cromatografia em Gel , Cisteína , Imunoconjugados , Espectrometria de Massas , Imunoconjugados/química , Imunoconjugados/análise , Cisteína/química , Reprodutibilidade dos Testes , Cromatografia em Gel/métodos , Espectrometria de Massas/métodos , Modelos Lineares , Anticorpos Monoclonais/química , Anticorpos Monoclonais/análise , Limite de Detecção , Humanos , Fluxo de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...