Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 242
Filtrar
1.
Sci Justice ; 64(5): 543-548, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39277336

RESUMO

Y chromosome short tandem repeats (Y-STRs) typing is a useful tool in scenarios such as mass graves analysis or disaster victim identification and has become a routine analysis in many laboratories. Not many comparisons have been performed with the currently available commercial kits, much less with degraded skeletal remains. This research aims to evaluate the performance of three commercial Y-STR kits: Yfiler™ Plus, PowerPlex® Y23, and Investigator® Argus Y-28 in 63 degraded skeletal remains from mass graves. PowerPlex® Y23 yields more reportable markers and twice the RFU on average, while Yfiler™ Plus and Investigator® Argus Y-28 exhibited a similar behaviour. Additionally, Argus Y-28, which has not been tested with this kind of samples in literature before, showed a good performance. Finally, a predictive model was attempted to be developed from quantification and autosomal STR data. However, no acceptable model could be obtained. Nevertheless, good Y-STR typing results may be expected if at least 50 pg DNA input is used or 13 autosomal markers were previously obtained.


Assuntos
Restos Mortais , Cromossomos Humanos Y , Impressões Digitais de DNA , Repetições de Microssatélites , Humanos , Impressões Digitais de DNA/métodos , Masculino , Reação em Cadeia da Polimerase , Degradação Necrótica do DNA , Osso e Ossos/química
2.
Forensic Sci Int ; 362: 112184, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39098141

RESUMO

The petrous bone contains significantly higher amounts of DNA than any other human bone. Because of highly destructive sampling and because it is not always part of the recovered remains, the need for alternative sources of DNA is important. To identify additional optimal bone types, petrous bones were compared to femurs, tali, and calcanei sampled from 66 adult skeletons from two distinct modern-era Christian cemeteries. An extraction method employing full demineralization was used to obtain DNA, real-time PCR quantification to ascertain DNA quantity and degradation, and a commercial forensic short tandem repeats (STR) PCR amplification kit to determine genetic profiles. Statistical analysis was performed to explore the differences in DNA yield, DNA degradation, and success of STR amplification. A systematic studies exploring intra-skeletal variability in DNA preservation including various excavation sites differing by time period and geographical position are rare, and the second part of the investigation was based on a comparison of both archaeological sites, which allowed us to compare the effect of different post-mortem intervals and environmental conditions on DNA preservation. The older burial site in Crnomelj was active between the 13th and 18th century, whereas the more recent Polje burial was in use from the 16th to 19th century, creating different temporal and geographical environments. Results for the Crnomelj burial site revealed that the petrous bone outperformed all other bone types studied, except the calcaneus. At the Polje archeological site calcanei, tali, and femurs yielded the same STR typing success as petrous bones. The results obtained highlight the importance of careful bone sample selection for DNA analysis of aged skeletal remains. In addition to petrous bones, calcanei were found to be an alternative source of DNA when older burial sites are investigated. When more recent burial sites are processed, calcanei, tali, and femurs should be sampled besides petrous bones, not only because they exhibited good performance, but also because of easier sampling and easier grinding in the case of trabecular bones. This study contributes valuable insights into the potential use of various skeletal types as a source of DNA for investigation of aged skeletal remains, and it offers practical implications for forensic and archaeological investigations.


Assuntos
Impressões Digitais de DNA , DNA , Repetições de Microssatélites , Reação em Cadeia da Polimerase em Tempo Real , Humanos , Impressões Digitais de DNA/métodos , Masculino , DNA/análise , DNA/isolamento & purificação , Adulto , Pessoa de Meia-Idade , Feminino , Restos Mortais , Degradação Necrótica do DNA , Idoso , Fêmur/química , Fêmur/anatomia & histologia , História Medieval , Osso e Ossos/química , Osso Petroso/química , Osso Petroso/anatomia & histologia , Idoso de 80 Anos ou mais , Antropologia Forense/métodos , Adulto Jovem , Calcâneo/anatomia & histologia
3.
Forensic Sci Int Genet ; 72: 103089, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38905753

RESUMO

Biological trace samples consisting of very few cells pose a challenge to conventional forensic genetic DNA analysis. RNA may be an alternative to DNA when handling low template samples. Whereas each cell only contains two copies of an autosomal DNA segment, the transcriptome retains much of the genomic variation replicated in abundant RNA fragments. In this study, we describe the development of a prototype RNA-based SNP selection set for forensic human identification from low template samples (50 pg gDNA). Whole blood from a subset of the Danish population (41 individuals) and blood stains subjected to degradation at room temperature for up to two weeks were analysed by whole transcriptome shotgun sequencing. Concordance was determined by DNA genotyping with the Infinium Omni5-4 SNP chip. In the 100 protein-coding genes with the most reads, 5214 bi-allelic SNPs with gnomAD minor allele frequencies > 0.1 in the African/African American, East Asian, and (non-Finnish) European populations were identified. Of these, 24 SNPs in 21 genes passed screening in whole blood and degraded blood stains, with a resulting mean match probability of 4.5 ∙ 10-9. Additionally, ancestry informative SNPs and SNPs in genes useful for body fluid identification were identified in the transcriptome. Consequently, shotgun sequencing of RNA from low template samples may be used for a vast host of forensic genetics purposes, including simultaneous human and body fluid identification, leading to direct donor identification in the identified body fluid.


Assuntos
Polimorfismo de Nucleotídeo Único , Humanos , Transcriptoma , Frequência do Gene , Genética Forense/métodos , Impressões Digitais de DNA , Dinamarca , Degradação Necrótica do DNA , Manchas de Sangue , Grupos Raciais/genética
4.
J Forensic Sci ; 69(5): 1861-1870, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38898623

RESUMO

The NGM Detect™ PCR Amplification Kit was designed particularly for genotyping degraded casework samples. This study aimed to validate the half-volume amplification of the kit and to present its successful long-term application. The validation was performed in accordance to the corresponding guidelines of the Scientific Working Group on DNA analysis methods and the European Network of Forensic Science Institutes. For validation parameters, such as sensitivity, reproducibility, and repeatability, polymerase chain reactions (PCR) were set up both manually and robotically, applying 29 cycles. For PCRs with sub-optimal DNA input (≤0.5 ng) the cycle numbers were increased to 31. Regardless of the PCR preparation method, the optimal 0.5 ng DNA input produced optimal allelic peak heights with no allelic dropout. The first alleles that failed to amplify started to appear at the level of 0.0375 ng input DNA, although the manually prepared PCRs produced fewer missing alleles. In this case, the raised cycle number produced 1.9% and 4.4% of dropout for manually and for robotically set up PCRs, respectively. In the case of 84 degraded casework samples, PCRs were prepared only by hand. The kit was able to provide informative profiles for 78.57%, 70.37%, and 69.77% for lowly, moderately, and highly degraded samples, respectively. Allelic dropouts were 26.05%, 44.88%, and 51.23% for the same groups. According to our results, we strongly recommend using the NGM Detect™ Kit in half-volume PCR system and encourage the usage of the kit in the particular cases when other kits fail to produce a complete DNA profile.


Assuntos
Degradação Necrótica do DNA , Impressões Digitais de DNA , Repetições de Microssatélites , Reação em Cadeia da Polimerase , Humanos , Reação em Cadeia da Polimerase/métodos , Impressões Digitais de DNA/métodos , Reprodutibilidade dos Testes , Alelos , Genótipo
5.
Genes (Basel) ; 15(5)2024 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-38790251

RESUMO

The assessment of degradation is crucial for the analysis of human DNA samples isolated from forensic specimens. Forensic quantitative PCR (qPCR) assays can include multiple targets of varying amplicon size that display differential amplification efficiency, and thus different concentrations, in the presence of degradation. The possibility of deriving information on DNA degradation was evaluated in a forensic qPCR assay not specifically designed to detect DNA fragmentation, the Plexor HY (Promega), by calculating the ratio between the estimated concentrations of autosomal (99 bp) and Y-chromosomal (133 bp) targets ("[Auto]/[Y]"). The [Auto]/[Y] ratio measured in 57 formalin-fixed, paraffin-embedded samples was compared to a quality score (QS) calculated for corresponding STR profiles using quantitative data (allele peak height). A statistically significant inverse correlation was observed between [Auto]/[Y] and QS (R = -0.65, p < 0.001). The [Auto]/[Y] values were highly correlated (R = 0.75, p < 0.001) with the "[Auto]/[D]" values obtained using the PowerQuant (Promega) assay, expressly designed to detect DNA degradation through simultaneous quantification of a short (Auto) and a long (D) autosomal target. These results indicate that it is possible to estimate DNA degradation in male samples through Plexor HY data and suggest an alternative strategy for laboratories lacking the equipment required for the assessment of DNA integrity through dedicated qPCR assays.


Assuntos
Cromossomos Humanos Y , DNA , Reação em Cadeia da Polimerase em Tempo Real , Humanos , Masculino , DNA/genética , Cromossomos Humanos Y/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase em Tempo Real/normas , Genética Forense/métodos , Repetições de Microssatélites/genética , Degradação Necrótica do DNA , Fragmentação do DNA , Impressões Digitais de DNA/métodos
6.
Forensic Sci Int ; 360: 112046, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38718526

RESUMO

Research into the recovery of DNA from illicit drug samples has shown it is possible to get forensically useful profiles from such substrates. However, it is not yet known if the different physical states that drugs can be found in influences the quantity and quality of DNA that can be recovered or what is the best sampling method to adopt for powdered samples. This research used acetaminophen in four different states - large crystalline, powder, in solution, or residue - to determine the efficacy of current DNA technology in recovery and analysis of the resulting sample. Five replicates of each were prepared. Human blood was deposited on or mixed with the drug and left for 1 hour. The surface of the drug was sampled by wet/dry swabbing (where appropriate), or the entire sample was deposited in a tube, and the DNA then extracted using DNA-IQ™. The amount of DNA recovered (ng), degradation index, number of PCR cycles (Ct) required for the IPC to reach threshold, number of alleles in the DNA profile and average peak height (APH) were assessed. All samples, irrespective of the physical state they were collected from, returned full DNA profiles that corresponded to the DNA profile of the blood donor, with no degradation or inhibition detected. It was also found the wet/dry swabbing method returned higher levels of DNA than inclusion of the entire sample into the tube for powdered acetaminophen and the appropriate method to use will be dependent on casework circumstances. The findings of this research further develops our understanding of the recovery of DNA from drugs, and supports the need for further investigation to understand under what conditions DNA can be recovered from illicit substances.


Assuntos
Acetaminofen , Impressões Digitais de DNA , DNA , Reação em Cadeia da Polimerase , Manejo de Espécimes , Acetaminofen/sangue , Humanos , DNA/isolamento & purificação , Manejo de Espécimes/métodos , Impressões Digitais de DNA/métodos , Pós , Repetições de Microssatélites , Analgésicos não Narcóticos , Degradação Necrótica do DNA
7.
Forensic Sci Int ; 358: 112010, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38581825

RESUMO

We used a nanopore sequencer to quantify DNA fragments > 10,000 bp in size and then evaluated their relationship with short-term bloodstain age. Moreover, DNA degradation was investigated after bloodstains were wetted once with water. Bloodstain samples on cotton gauze were stored at room temperature and low humidity for up to 6 months. Bloodstains stored for 1 day were wetted with nuclease-free water, allowed to dry, and stored at room temperature and low humidity for up to 1 week. The proportion of fragments > 20,000 bp in dry bloodstains tended to decrease over time, particularly for fragments > 50,000 bp in size. This trend was modeled using a power approximation curve, with the highest R2 value (0.6475) noted for fragments > 50,000 bp in size; lower values were recorded for shorter fragments. The proportion of longer fragments was significantly reduced in bloodstains that were dried after being wetted once, and there was significant difference in fragments > 50,000 bp between dry conditions and once-wetted. This result suggests that even temporary exposure to water causes significant DNA fragmentation, but not extensive degradation. Thus, bloodstains that appear fresh but have a low proportion of long DNA fragments may have been wetted previously. Our results indicate that evaluating the proportion of long DNA fragments yields information on both bloodstain age and the environment in which they were stored.


Assuntos
Manchas de Sangue , DNA , Nanoporos , Manejo de Espécimes , Humanos , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos , Análise de Sequência de DNA , Degradação Necrótica do DNA , Fatores de Tempo , Fragmentação do DNA , Impressões Digitais de DNA/instrumentação , Impressões Digitais de DNA/métodos
8.
Int J Legal Med ; 138(4): 1273-1285, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38491322

RESUMO

In recent years, molecular biology-based diagnostic techniques have made remarkable strides and are now extensively utilized in clinical practice, providing invaluable insights for disease diagnosis and treatment. However, forensic medicine, especially forensic pathology, has witnessed relatively limited progress in the application of molecular biology technologies. A significant challenge in employing molecular techniques for forensic diagnoses lies in the quantitative and qualitative changes observed in diagnostic markers due to sample degradation-a recognized and formidable obstacle. Inspired by the success of DNA sequencing in forensic practices, which enables accurate individual identification even in cases involving degraded and deteriorated tissues and organs, we propose the application of the assay for transposase-accessible chromatin with sequencing (ATAC-seq) to identify targets at the transcriptional onset, exploring chromatin and DNA-level alterations for injury and disease inference in forensic samples. This study employs ATAC-seq to explore alterations in chromatin accessibility post-injury and their subsequent changes over a 2-h degradation period, employing traumatic brain injury (TBI) as a representative model. Our findings reveal high sensitivity of chromatin accessibility sites to injury, evidenced by shifts in thousands of peak positions post-TBI. Remarkably, these alterations remain largely unaffected by early degradation. Our results robustly endorse the notion that integrating and incorporating these specific loci for injury and disease diagnosis in forensic samples holds tremendous promise for practical application. We further validated the above results using human cortical tissue, which supported that early degradation did not significantly affect chromatin accessibility. This pioneering advancement in molecular diagnostic techniques may revolutionize the field of forensic science, especially forensic pathology.


Assuntos
Cromatina , Lesões Encefálicas Traumáticas/genética , Lesões Encefálicas Traumáticas/diagnóstico , Humanos , Análise de Sequência de DNA/métodos , Transposases/genética , Degradação Necrótica do DNA , Sequenciamento de Nucleotídeos em Larga Escala
9.
Int J Legal Med ; 138(4): 1287-1293, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38509248

RESUMO

Forensic DNA analysis in compromised skeletal remains may pose challenges due to DNA degradation, often resulting in partial or negative autosomal STRs profiles. To address this issue, alternative approaches such as mitochondrial DNA or SNPs typing may be employed; however, they are labour-intensive and costly. Insertion-null alleles (INNULs), short interspersed nuclear elements, have been suggested as a valuable tool for human identification in challenging samples due to their small amplicon size. A commercial kit including 20 INNULs markers along with amelogenin (InnoTyper® 21) has been developed. This study assesses its utility using degraded skeletal remains, comparing the results obtained (the number of detected alleles, RFU values, PHR, and the number of reportable markers) to those obtained using GlobalFiler™. Subsequently, the random match probability of the two profiles for each sample was determined using Familias version 3 to evaluate the power of discrimination of the results obtained from each kit. In every sample, InnoTyper® 21 yielded more alleles, higher RFU values, and a greater number of reportable loci. However, in most cases, both profiles were similarly informative. In conclusion, InnoTyper® 21 serves as a valuable complement to the analysis of challenging samples in cases where a poor or negative profile was obtained.


Assuntos
Restos Mortais , Impressões Digitais de DNA , Humanos , Marcadores Genéticos , Impressões Digitais de DNA/métodos , Amelogenina/genética , Alelos , Degradação Necrótica do DNA , Repetições de Microssatélites , Elementos Nucleotídeos Curtos e Dispersos , Reação em Cadeia da Polimerase , Masculino
10.
J Forensic Sci ; 69(5): 1558-1577, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38415845

RESUMO

Genetic assessment of highly incinerated and/or degraded human skeletal material is a persistent challenge in forensic DNA analysis, including identifying victims of mass disasters. Few studies have investigated the impact of thermal degradation on whole-genome single-nucleotide polymorphism (SNP) quality and quantity using next-generation sequencing (NGS). We present whole-genome SNP data obtained from the bones and teeth of 27 fire victims using two DNA extraction techniques. Extracts were converted to double-stranded DNA libraries then enriched for whole-genome SNPs using unpublished biotinylated RNA baits and sequenced on an Illumina NextSeq 550 platform. Raw reads were processed using the EAGER (Efficient Ancient Genome Reconstruction) pipeline, and the SNPs filtered and called using FreeBayes and GATK (v. 3.8). Mixed-effects modeling of the data suggest that SNP variability and preservation is predominantly determined by skeletal element and burn category, and not by extraction type. Whole-genome SNP data suggest that selecting long bones, hand and foot bones, and teeth subjected to temperatures <350°C are the most likely sources for higher genomic DNA yields. Furthermore, we observed an inverse correlation between the number of captured SNPs and the extent to which samples were burned, as well as a significant decrease in the total number of SNPs measured for samples subjected to temperatures >350°C. Our data complement previous analyses of burned human remains that compare extraction methods for downstream forensic applications and support the idea of adopting a modified Dabney extraction technique when traditional forensic methods fail to produce DNA yields sufficient for genetic identification.


Assuntos
Restos Mortais , Osso e Ossos , Queimaduras , Incêndios , Sequenciamento de Nucleotídeos em Larga Escala , Polimorfismo de Nucleotídeo Único , Dente , Humanos , Dente/química , Queimaduras/genética , Osso e Ossos/química , Análise de Sequência de DNA , Genoma Humano , DNA/isolamento & purificação , Degradação Necrótica do DNA , Masculino , Feminino
11.
Int J Legal Med ; 138(4): 1255-1264, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38416217

RESUMO

Massively parallel sequencing allows for integrated genotyping of different types of forensic markers, which reduces DNA consumption, simplifies experimental processes, and provides additional sequence-based genetic information. The STRseqTyper122 kit genotypes 63 autosomal STRs, 16 X-STRs, 42 Y-STRs, and the Amelogenin locus. Amplicon sizes of 117 loci were below 300 bp. In this study, MiSeq FGx sequencing metrics for STRseqTyper122 were presented. The genotyping accuracy of this kit was examined by comparing to certified genotypes of NIST standard reference materials and results from five capillary electrophoresis-based kits. The sensitivity of STRseqTyper122 reached 125 pg, and > 80% of the loci were correctly called with 62.5 pg and 31.25 pg input genomic DNA. Repeatability, species specificity, and tolerance for DNA degradation and PCR inhibitors of this kit were also evaluated. STRseqTyper122 demonstrated reliable performance with routine case-work samples and provided a powerful tool for forensic applications.


Assuntos
Impressões Digitais de DNA , Sequenciamento de Nucleotídeos em Larga Escala , Repetições de Microssatélites , Humanos , Impressões Digitais de DNA/métodos , Amelogenina/genética , Reprodutibilidade dos Testes , Análise de Sequência de DNA/métodos , Genótipo , Reação em Cadeia da Polimerase , Especificidade da Espécie , Masculino , Animais , Degradação Necrótica do DNA , Eletroforese Capilar , Feminino
12.
Methods Mol Biol ; 2685: 189-204, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37439983

RESUMO

The QIAGEN Investigator® Quantiplex® Pro Kit is a real-time quantitative PCR assay utilized by forensic DNA laboratories to determine the amount of amplifiable human and male DNA in a sample prior to downstream amplification of specific STR markers for human identity testing. This quantification method includes two internal controls that assist the analyst in a preliminary evaluation of the sample in regard to both inhibition or degradation that may be present in the sample and subsequently affect the more targeted downstream amplification of specific markers for identity testing. The internal controls are analogous to the quality sensors contained in QIAGEN's Investigator® 24plex line of amplification kits, ensuring that the sample's performance in the quantitation step can accurately predict the success of the STR amplification results. This chapter describes the physical plate setup of a quantitative PCR assay utilizing the QIAGEN Investigator® Quantiplex® Pro Kit as well as the steps and software configurations involved in running such a plate on the Applied Biosystems 7500 Real-Time PCR System for Human Identification using HID Real-Time PCR Analysis Software v1.1 or 1.2.


Assuntos
Impressões Digitais de DNA , Repetições de Microssatélites , Masculino , Humanos , Repetições de Microssatélites/genética , Reação em Cadeia da Polimerase em Tempo Real , DNA/análise , Degradação Necrótica do DNA
13.
Forensic Sci Med Pathol ; 19(1): 50-59, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36355320

RESUMO

Several commercially available quantitative real-time PCR (qPCR) systems enable highly sensitive detection of human DNA and provide a degradation index (DI) to assess DNA quality. From routine casework in forensic genetics, it was observed that DNA degradation in forensic samples such as blood samples stored under sub-optimal conditions leads to visible effects in multiplex analyses of short tandem repeat markers (STRs) due to decreased amplification efficiencies in longer amplicons. It was further noticed that degradation indices often remain below the value that is considered to be critical. Thus, the aim of this work was to systematically analyze this effect and to compare conventional qPCR assays with a modified qPCR approach using uracil DNA glycosylase (UNG) and DNA quality assessment methods based on electrophoresis. Blood samples were stored at three different storage temperatures for up to 316 days. Significantly increased DNA recovery was observed from samples stored at high temperatures (37 °C) compared samples stored at room temperature and 4 °C. We observed typical effects of degradation in STR analyses but no correlation between DI and storage time in any of the storage conditions. Adding UNG slightly increased the sensitivity of detecting DNA degradation in one of the qPCR kits used in this study. This observation was not confirmed when using a second qPCR system. Electrophoretic systems did also not reveal significant correlations between integrity values and time. Methods for detecting DNA degradation are usually limited to the detection of DNA fragmentation, and we conclude that degradation affecting forensic STR typing is more complex.


Assuntos
Coleta de Amostras Sanguíneas , Impressões Digitais de DNA , DNA , Humanos , DNA/análise , Dano ao DNA , Degradação Necrótica do DNA , Impressões Digitais de DNA/métodos , Repetições de Microssatélites , Reação em Cadeia da Polimerase em Tempo Real
14.
J Forensic Leg Med ; 83: 102251, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34592482

RESUMO

The time frames between death and reporting of the cadaver, known as post Mortem interval (PMI), is essential in investigation of homicide deaths, suspicious deaths, or other untimely deaths as well as natural deaths. Such information helps to connect the missing links in homicide or other relevant cases. Over the time several methods are developed which depends upon factors as several methods physiological, biochemical, entomological, and archaeological for the estimation of degradation of body with time. These methods lack precision, require expertise to achieve worthy results or authentic estimate. Although these methods are currently in use but, these evaluations are still unreliable and imprecise. Hence, we still need new methods for better estimation of PMI. Initially, the predictable morphological and chemical changes in cadaver are used as PMI indicators but, as the time since death increases, the above methods become less useful for as they can't pin point the time of death rather give a ballpark idea. With the advent of the field of molecular biology, the estimation of PMI is proposed to be executed by evaluating the degradation pattern of the biological markers (DNA, RNA, and Proteins). It is now proved that the DNA is fairly unwavering over long post-mortem phases, RNA is much more labile in nature, and sensitive to degradation in a tissue-specific manner. Thus, the main purpose (aim, agenda) of this document is to provide review that mainly focuses on potential use of RNA markers in estimation of PMI. For this Critical Review, the systematic evaluation of 47 studies is executed according to the chosen inclusion and exclusion criteria.


Assuntos
Degradação Necrótica do DNA , Medicina Legal , Técnicas de Diagnóstico Molecular , Proteólise , Estabilidade de RNA , Animais , Biomarcadores , Humanos , Mudanças Depois da Morte
15.
Hepatol Commun ; 5(10): 1737-1754, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34532999

RESUMO

Hepatic cell death occurs in response to diverse stimuli such as chemical and physical damage. The exposure of intracellular contents such as DNA during necrosis induces a severe inflammatory response that has yet to be fully explored therapeutically. Here, we sought means to neutralize the ability of extracellular DNA to induce deleterious tissue inflammation when drug-induced liver injury had already ensued. DNA exposure and inflammation were investigated in vivo in drug-induced liver injury using intravital microscopy. The necrotic DNA debris was studied in murine livers in vivo and in DNA debris models in vitro by using a positively charged chemokine-derived peptide (MIG30; CXCL9[74-103]). Acetaminophen-induced liver necrosis was associated with massive DNA accumulation, production of CXC chemokines, and neutrophil activation inside the injured tissue. The MIG30 peptide bound the healthy liver vasculature and, to a much greater extent, to DNA-rich necrotic tissue. Moreover, MIG30 bound extracellular DNA directly in vivo in a charge-dependent manner and independently of glycosaminoglycans and chemokines. Post-treatment of mice with MIG30 reduced mortality, liver damage, and inflammation significantly. These effects were not observed with a control peptide that does not bind DNA. Mechanistically, MIG30 inhibited the interaction between DNA and histones, and promoted the dissociation of histones from necrotic debris. MIG30 also inhibited the pro-inflammatory effect of CpG DNA, as measured by a reduction in CXCL8 production, indicating that MIG30 disturbs the ability of DNA to induce hepatic inflammation. Conclusion: The use of DNA-binding peptides reduces necrotic liver injury and inflammation, even at late timepoints.


Assuntos
Anti-Inflamatórios/farmacologia , Doença Hepática Induzida por Substâncias e Drogas/tratamento farmacológico , Degradação Necrótica do DNA/efeitos dos fármacos , Fígado/patologia , Peptídeos/farmacologia , Acetaminofen/efeitos adversos , Animais , Doença Hepática Induzida por Substâncias e Drogas/genética , Quimiocina CXCL9/efeitos dos fármacos , Quimiocinas CXC/efeitos dos fármacos , Modelos Animais de Doenças , Matriz Extracelular/genética , Histonas/efeitos dos fármacos , Humanos , Interleucina-8/efeitos dos fármacos , Fígado/efeitos dos fármacos , Camundongos , Necrose/induzido quimicamente , Necrose/patologia , Ativação de Neutrófilo/efeitos dos fármacos , Eletricidade Estática
16.
Forensic Sci Int Genet ; 54: 102538, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34265517

RESUMO

Research on ancient and forensic DNA is related in many ways, and the two fields must deal with similar obstacles. Therefore, communication between these two communities has the potential to improve results in both research fields. Here, we present the insights gained in the ancient DNA community with regard to analyzing DNA from aged skeletal material and the potential use of the developed protocols in forensic work. We discuss the various steps, from choosing samples for DNA extraction to deciding between classical PCR amplification and massively parallel sequencing approaches. Based on the progress made in ancient DNA analyses combined with the requirements of forensic work, we suggest that there is substantial potential for incorporating ancient DNA approaches into forensic protocols, a process that has already begun to a considerable extent. However, taking full advantage of the experiences gained from ancient DNA work will require comparative studies by the forensic DNA community to tailor the methods developed for ancient samples to the specific needs of forensic studies and case work. If successful, in our view, the benefits for both communities would be considerable.


Assuntos
DNA Antigo , DNA , Idoso , DNA/genética , Degradação Necrótica do DNA , Impressões Digitais de DNA , Genética Forense , Humanos
17.
Forensic Sci Med Pathol ; 17(4): 660-664, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34292481

RESUMO

Genetic analyses such as STR-typing are routinely used for identification purposes in forensic casework. Although genotyping techniques only require a minimum amount of DNA to provide a genetic profile, DNA quality differs not only between but also within tissues during ongoing decomposition. Initiated by a recent case where, due to the constitution of the body, preferred tissue was not available or only resulted in a partial and not usable DNA profile, the analysis of intervertebral discs as a source of DNA was considered. As the analysis of this tissue resulted in a high quality DNA profile a further study was performed in which thirty intervertebral discs dissected from bodies in different stages of decay were analyzed. All samples yielded good quality DNA in quantities suitable for STR-based amplification with no or only low degradation indices, resulting in complete genetic profiles. These results demonstrate the robustness of human intervertebral disc tissue as a source of DNA for molecular identification purposes.


Assuntos
Impressões Digitais de DNA , Disco Intervertebral , DNA , Degradação Necrótica do DNA , Humanos , Repetições de Microssatélites
18.
Forensic Sci Int ; 325: 110859, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34098475

RESUMO

The identification of skeletal human remains, severely compromised by putrefaction, or highly deteriorated, is important for legal and humanitarian reasons. There are different tools that can help in the identification process such as anthropological and genetic studies. The success observed during the last decade in genetic analysis of skeletal remains has been possible especially due to the refinements of DNA extraction and posterior analysis techniques. However, despite these progresses, many challenges keep influencing the results of such analysis, mainly the limited amount and the degradation of the DNA recovered from badly preserved samples. By now, there is still no wide-range knowledge about post-mortem kinetics of DNA degradation. Therefore, taphonomy studies can play a key role in the reconstruction of post-mortem transformations that skeletal remains, and consequently DNA, have undergone. Thus, the goal of the present review focuses on the assessment of the literature regarding the possible effect of intrinsic (characteristics of the bone) and extrinsic (environmental) factors on the state of preservation of skeletal remains recovered in a terrestrial environment and their genetic material. The establishment of useful indicators describing the state of the remains is a key factor in order to determine their suitability for posterior biomolecular analysis.


Assuntos
Restos Mortais , Degradação Necrótica do DNA , DNA/análise , Mudanças Depois da Morte , Densidade Óssea , Osso e Ossos/química , Osso e Ossos/patologia , Colágeno/metabolismo , Impressões Digitais de DNA , Medicina Legal , Água Subterrânea , Humanos , Umidade , Concentração de Íons de Hidrogênio , Solo/química , Microbiologia do Solo , Temperatura , Dente/química , Dente/patologia
19.
Int J Legal Med ; 135(5): 1695-1707, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34031722

RESUMO

Freezing bone samples to preserve their biomolecular properties for various analyses at a later time is a common practice. Storage temperature and freeze-thaw cycles are well-known factors affecting degradation of molecules in the bone, whereas less is known about the form in which the tissue is most stable. In general, as little intervention as possible is advised before storage. In the case of DNA analyses, homogenization of the bone shortly before DNA extraction is recommended. Because recent research on the DNA yield from frozen bone fragments and frozen bone powder indicates better DNA preservation in the latter, the aim of the study presented here was to investigate and compare the chemical composition of both types of samples (fragments versus powder) using ATR-FTIR spectroscopy. Pairs of bone fragments and bone powder originating from the same femur of 57 individuals from a Second World War mass grave, stored in a freezer at - 20 °C for 10 years, were analyzed. Prior to analysis, the stored fragments were ground into powder, whereas the stored powder was analyzed without any further preparation. Spectroscopic analysis was performed using ATR-FTIR spectroscopy. The spectra obtained were processed and analyzed to determine and compare the chemical composition of both types of samples. The results show that frozen powdered samples have significantly better-preserved organic matter and lower concentrations of B-type carbonates, but higher concentrations of A-type carbonates and stoichiometric apatite. In addition, there are more differences in the samples with a low DNA degradation index and less in the samples with a high DNA degradation index. Because the results are inconsistent with the current understanding of bone preservation, additional research into optimal preparation and long-term storage of bone samples is necessary.


Assuntos
Osso e Ossos/química , DNA/análise , Fêmur/química , Preservação de Tecido/métodos , Apatitas/análise , Restos Mortais/química , Carbonatos/análise , Colágeno/análise , Degradação Necrótica do DNA , Congelamento , Humanos , Masculino , Mudanças Depois da Morte , Refrigeração , Eslovênia/etnologia , Espectroscopia de Infravermelho com Transformada de Fourier , Fatores de Tempo , II Guerra Mundial
20.
Int J Legal Med ; 135(4): 1319-1327, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33880634

RESUMO

When decomposition of a recovered body is fairly advanced, identification based on common morphologic features is often impossible. In these cases, short tandem repeat (STR) marker genotyping has established itself as a convenient and reliable alternative. However, at very progressed stages of decomposition, postmortem tissue putrefaction processes can decrease DNA yields considerably. Hence, not all types of tissue are equally suitable for successful STR marker-based postmortem identification. Bone or dental material is often analysed in corpses with advanced decompositional changes. However, processing of these materials is very elaborate and time and resource consuming. We have therefore focused on the suitableness of various types of soft tissue swabs, where DNA extraction is easier and faster. By sampling 28 bodies at various stages of decomposition, we evaluated the suitability of different tissues for genotyping at varying degrees of physical decay. This was achieved by a systematic classification of the sampled bodies by morphological scoring and subsequent analysis of multiple tissue swabs of the aortic wall, urinary bladder wall, brain, liver, oral mucosa and skeletal muscle. In summary, we found variable degrees of suitability of different types of soft tissue swabs for DNA-based identification. Swabs of the aortic wall, the urinary bladder wall and brain tissue yielded the best results - in descending order - even at advanced levels of decay.


Assuntos
Restos Mortais/química , DNA/isolamento & purificação , Antropologia Forense/métodos , Aorta/química , Química Encefálica , Degradação Necrótica do DNA , Impressões Digitais de DNA/métodos , Feminino , Humanos , Fígado/química , Masculino , Repetições de Microssatélites , Mucosa Bucal/química , Músculo Esquelético/química , Mudanças Depois da Morte , Bexiga Urinária/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...