Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.669
Filtrar
1.
PLoS One ; 19(6): e0304120, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38843221

RESUMO

OBJECTIVE(S): To estimate continuation rates for postpartum intrauterine contraceptive device (PPIUD) at 6 weeks, 6 months and 1-year within existing programs in an under-resourced setting, and to identify determinants of discontinuation, removal and expulsion. STUDY DESIGN: We used a prospective cohort design and enrolled recent PPIUD adopter women across 100 public healthcare facilities in Odisha and Chhattisgarh, India. We collected their socio-demographic information and followed them up telephonically at 6 weeks, 6 months and 1 year for complications and continuation status. We assessed PPIUD continuation rates and factors associated with PPIUD discontinuation, removal, and expulsion using Cox proportional hazards modelling. RESULTS: We enrolled 916 participants (579 (63.2%) from Odisha and 337 (36.8%) from Chhattisgarh). The continuation rate of PPIUD was 88.7% at 6 weeks, 74.8% at 6 months 60.1% at one year. Once discontinued, chances of not opting for any family planning method was high (up to 81.2%). Participants with education of 6th to 12th class and those experiencing complications (pain abdomen, bleeding and discharge per vaginum) were more likely to remove the IUD with adjusted hazard ratio of 1.82 (95% CI: 1.18-2.79) and 4.39 (95% CI: 3.25-5.93) respectively. For expulsion, we did not find any factor that was statistically significant. CONCLUSION(S): PPIUD continuation rates declined considerably after the initial 6 weeks. Counselling and follow-up services for managing complications must be strengthened, especially in the first 6 weeks of PPIUD insertion, to enhance and sustain programmatic impact. IMPLICATIONS: Our findings emphasize on the need to strengthen client counseling and follow-up for management of complications, especially in the first 6 weeks of insertion of PPIUDs. Ongoing programs need to address comprehensive capacity building efforts in this regard.


Assuntos
Dispositivos Intrauterinos , Período Pós-Parto , Humanos , Feminino , Índia/epidemiologia , Adulto , Estudos Prospectivos , Dispositivos Intrauterinos/efeitos adversos , Dispositivos Intrauterinos/estatística & dados numéricos , Adulto Jovem , Serviços de Planejamento Familiar , Modelos de Riscos Proporcionais , Adolescente
2.
Sci Rep ; 14(1): 11385, 2024 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-38762680

RESUMO

This article aims to report the comprehensive and up-to-date analysis and evidence of the insertion rate, expulsion rate, removal rate, and utilization rate of immediate placement of intrauterine devices (IUDs) versus delayed placement after artificial abortion. PubMed, Embase, Cochrane, Web of Science, CNKI, and Wanfang databases were comprehensively searched up to January 12, 2024 for studies that compared immediate versus delayed insertion of IUDs after abortion. The evaluation metrics included the number of IUD insertion after surgical or medical abortions, the frequency of expulsion and removal at 6 months or 1 year, the number of continued usage, pain intensity scores, the number of infections, the duration of bleeding, and instances of uterine perforation during or after IUD insertion. Ten randomized controlled articles were eligible, comprising 11 research projects, of which 3 projects involved the placement of an IUD after surgical abortion, and 8 projects involved the placement of an IUD after medical abortion. This included 2025 patients (977 in the immediate insertion group and 1,048 in the delayed insertion group). We summarized all the extracted evidence. The meta-analysis results indicated that for post-surgical abortions, the immediate insertion group exhibited a higher IUD placement rate than the delayed insertion group. After medical abortions, the immediate insertion group showed higher rates of IUD placement, utilization, and expulsion at 6 months or 1 year. The two groups showed no statistically significant differences in the removal rate, post-insertion infection rate, pain scores during insertion, and days of bleeding during the follow-up period. Compared to delayed placement, immediate insertion of IUDs can not only increase the usage rate at 6 months or 1 year but also enhance the placement rate.


Assuntos
Aborto Induzido , Dispositivos Intrauterinos , Humanos , Feminino , Dispositivos Intrauterinos/efeitos adversos , Aborto Induzido/efeitos adversos , Aborto Induzido/métodos , Gravidez , Fatores de Tempo , Remoção de Dispositivo
3.
Artigo em Inglês | MEDLINE | ID: mdl-38705006

RESUMO

OBJECTIVES: To assess women's contraceptive preferences in the immediate postpartum period and identify factors associated with use of their desired contraceptive method six months later. MATERIAL AND METHODS: This prospective cohort study included women ≤48 h after delivery at a single public Brazilian hospital. The women's interview took place in two different momentsbefore hospital discharge (in-person interview) and six months after delivery (by telephone contact). For data collection and management, we used the REDCap electronic tool. Univariate and multivariate analyses (unadjusted and adjusted Odds Ratio and 95 % confidence intervals) were used to identify factors associated with higher use of their desired contraceptive method six months after delivery. RESULTS: A total of 294 women (166 adolescents) were included. Initial contraceptive preferences were especially intrauterine devices (IUDs) (39.1 %), implants (33.0 %) and injectable hormonal contraceptives (17.0 %). Six months later, 42.5 % (n = 125) were using their desired contraceptive method. Younger age, white race and contraceptive initiation prior to hospital discharge were associated with use of their desired contraceptive at six months. CONCLUSION: Long-acting reversible contraception (LARC) methods were the most desired contraceptives among women after delivery. Providing and initiating free contraception prior to discharge from a birthing unit is important with regard to use of their desired method.


Assuntos
Comportamento Contraceptivo , Período Pós-Parto , Humanos , Feminino , Estudos Prospectivos , Adulto , Adolescente , Adulto Jovem , Comportamento Contraceptivo/estatística & dados numéricos , Brasil , Anticoncepção/métodos , Anticoncepção/estatística & dados numéricos , Dispositivos Intrauterinos/estatística & dados numéricos , Comportamento de Escolha , Contracepção Reversível de Longo Prazo/estatística & dados numéricos
4.
Reprod Biol Endocrinol ; 22(1): 49, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654308

RESUMO

STUDY OBJECTIVE: To evaluate the efficacy and pregnancy outcomes of intrauterine balloon and intrauterine contraceptive devices in the prevention of adhesion reformation following hysteroscopic adhesiolysis in infertile women with moderate to severe intrauterine adhesion. DESIGN: A prospective, randomized, controlled trial study. SETTING: A tertiary university hospital. PATIENTS: A total of 130 patients with moderate (American Fertility Society [AFS] score of 5-8) and severe (AFS score of 9-12) intrauterine adhesions were recruited. INTERVENTIONS: 86 patients were evenly allocated to group treated with an IUD for 1 month and group treated with an IUD for 2 months. 44 patients were allocated to group treated with a Foley catheter balloon.(IUD: Yuangong IUD). MEASUREMENTS AND MAIN RESULTS: The primary outcome measures were the AFS score, endometrial thickness, and pregnancy outcome. After hysteroscopy, the AFS score was significantly decreased(P<0.05), whereas endometrial thickness was significantly increased across the three groups(P<0.001). Notably, the decline in the AFS score in the balloon group was greater than that in the IUD-1-month group and IUD-2-month group(P<0.01), with no significant difference between the IUD groups(P = 0.298). Lastly, In addition, the extent of the increase in endometrial thickness(P = 0.502) and the pregnancy outcomes(P = 0.803) in the three groups were not significantly different. CONCLUSION: Inserting a balloon or placing an IUD for one or two months can effectively lower the risk of adhesion recurrence and restore the shape of the uterine cavity. While the therapeutic effect of the balloon was superior to that of the IUD, no significant differences were observed in the one-month and two-month IUD groups. TRIAL REGISTRATION: This research was registered in the Chinese Clinical Trial Registry ( http://www.chictr.org.cn/enIndex.aspx ); Clinical trial registry identification number: ChiCTR-IOR-17,011,943 ( http://www.chictr.org.cn/showprojen.aspx?proj=17979 ). Date of trial registration: July 11, 2017.


Assuntos
Histeroscopia , Infertilidade Feminina , Dispositivos Intrauterinos , Resultado da Gravidez , Humanos , Feminino , Aderências Teciduais/prevenção & controle , Adulto , Gravidez , Histeroscopia/métodos , Infertilidade Feminina/terapia , Infertilidade Feminina/etiologia , Infertilidade Feminina/prevenção & controle , Estudos Prospectivos , Doenças Uterinas/cirurgia , Doenças Uterinas/complicações , Doenças Uterinas/prevenção & controle , Doenças Uterinas/patologia , Resultado do Tratamento , Taxa de Gravidez
5.
Eur J Contracept Reprod Health Care ; 29(2): 69-75, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38651645

RESUMO

OBJECTIVE: To compare the performance of the abdominal handheld point-of-care ultrasonography (POCUS) Butterfly-iQ to gold standard transvaginal ultrasonography (US) in identifying the position of intrauterine devices (IUDs) in the hands of a medical doctor specialised in ultrasonography. METHODS: In this diagnostic accuracy study, a single operator conducted abdominal POCUS followed by conventional transvaginal US. Seventy patients utilising copper or hormonal IUDs were assessed between June 2021 and October 2022. IUDs were categorised as entirely within the uterine cavity or malpositioned. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated for detecting malpositioned IUDs, with conventional US results serving as the reference standard. Concordance rate and Kappa coefficient were computed to assess the agreement between the two ultrasound modalities. RESULTS: Among the 70 patients, 46 (65.7%) used copper IUDs, and 24 (34.3%) used hormonal IUDs. Conventional transvaginal US showed IUDs entirely within the uterine cavity in 56 (80%) patients and 14 (20%) IUDs were malpositioned. Of the 14 malpositioned IUDs seen by conventional US, POCUS identified 13 demonstrating a sensitivity of 92.9% (66.1-99.8). Of the 56 IUDs entirely within the uterine cavity shown by conventional US, only two cases were considered malpositioned by POCUS demonstrating a specificity of 96.4% (87.7-99.6). The concordance rate was 95.7%, and the Kappa value was 0.87 in differentiating between IUDs entirely within the uterine cavity and those that were malpositioned. CONCLUSION: Abdominal POCUS using Butterfly-iQ, when administered by an imaging specialist, exhibited excellent performance in confirming IUDs entirely within the uterine cavity.


Through a smartphone-based handheld point-of-care ultrasonography it was possible to correctly evaluate the position of intrauterine devices (IUDs) in a sample of 70 patients (46 using copper and 24 using hormonal IUDs).


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia , Humanos , Feminino , Ultrassonografia/métodos , Adulto , Sensibilidade e Especificidade , Dispositivos Intrauterinos/efeitos adversos , Pessoa de Meia-Idade , Útero/diagnóstico por imagem , Adulto Jovem , Dispositivos Intrauterinos de Cobre
6.
Eur J Contracept Reprod Health Care ; 29(3): 109-114, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38666336

RESUMO

OBJECTIVE: To examine the prevalence of infections with high-risk human papillomavirus (HPV) and cervical dysplasia, and the clearance rate of HPV infections, in users of different kinds of intrauterine devices (IUDs) and other contraceptive methods. METHODS: A cross-sectional register-based study including 16,181 women aged 30-49 years participating in the screening programme for cervical cancer in a Swedish County in 2017-2018. Data on contraception from screening records was paired with the HPV test results, cytological and histological follow-up tests and subsequent HPV test. RESULTS: There was no difference in the risk of being HPV positive, or histological HSIL+, between users of copper-containing IUDs and women with no reported use of contraception. Use of levonorgestrel intrauterine system and hormonal contraception were associated with higher odds for HPV infection in age-adjusted models (aOR 1.21; 95% CI 1.04-1.41, and aOR 1.41; 95% CI 1.22-1.63, respectively) and for HSIL+ (aOR 1.45; 95% CI 1.02-2.06, and aOR 1.56; 95% CI 1.13-2.16, respectively). No significant differences were found in HPV clearance rates. CONCLUSIONS: Reported use of levonorgestrel intrauterine system and hormonal contraception, but not use of copper IUD, was associated with a higher prevalence of HPV infections and histological HSIL + compared to no reported use of contraception.


Women using copper IUD showed no difference in prevalence of HPV or cervical dysplasia compared to women not using contraception in cross-sectional study.


Assuntos
Dispositivos Intrauterinos , Infecções por Papillomavirus , Displasia do Colo do Útero , Humanos , Feminino , Estudos Transversais , Adulto , Infecções por Papillomavirus/epidemiologia , Pessoa de Meia-Idade , Prevalência , Displasia do Colo do Útero/epidemiologia , Suécia/epidemiologia , Dispositivos Intrauterinos/efeitos adversos , Dispositivos Intrauterinos/estatística & dados numéricos , Levanogestrel , Dispositivos Intrauterinos de Cobre/efeitos adversos , Dispositivos Intrauterinos de Cobre/estatística & dados numéricos , Neoplasias do Colo do Útero/epidemiologia , Anticoncepção/estatística & dados numéricos , Anticoncepção/métodos , Dispositivos Intrauterinos Medicados/efeitos adversos
7.
Glob Health Sci Pract ; 12(2)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38589048

RESUMO

BACKGROUND: Couple-years of protection (CYP) is an indicator that allows for monitoring and evaluating of family planning (FP) program performance through simple calculations. The CYP for each contraceptive method is calculated by multiplying the number of contraceptive commodity units distributed to clients over a 1-year period by a conversion factor that quantifies the duration of contraceptive protection provided per unit distributed. CYP calculations across methods were previously updated in 2000 and 2011, resulting in changes in methodology, factor inclusion, and specific methods. Since the 2011 update, changes and additions to the modern contraceptive method mix required new CYP conversion factors for 4 methods of contraception: Levoplant implant, progestin-only pills (POPs), Caya diaphragm, and the hormonal intrauterine device. METHODS: We conducted literature reviews of both published and gray literature and consulted with experts to identify updated data on continuation rates, duration of efficacy, and method effectiveness for the 4 methods. New CYP conversion factors were calculated for the 4 methods either by using the same calculation used previously for the method considering new data or, for new methods, using calculations for similar methods. RESULTS: New CYP conversion factors were assigned to the 4 methods of contraception covered in this update: Levoplant, 2.5 CYP per implant inserted; POPs, 0.0833 CYP per pack (i.e., 12 cycles per CYP); Caya diaphragm, 1 CYP per device, and hormonal intrauterine device, 4.8 CYP per device inserted. CONCLUSIONS: CYP is an important indicator for FP programs. As new methods of contraception are developed and new evidence is generated for current methods, the indicator may need to be updated. A standard process for updating and documenting future CYP updates is recommended.


Assuntos
Anticoncepção , Serviços de Planejamento Familiar , Humanos , Feminino , Anticoncepção/métodos , Serviços de Planejamento Familiar/métodos , Dispositivos Intrauterinos
8.
J Strength Cond Res ; 38(7): 1256-1265, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38598545

RESUMO

ABSTRACT: Cabre, HE, Ladan, AN, Moore, SR, Joniak, KE, Blue, MNM, Pietrosimone, BG, Hackney, AC, and Smith-Ryan, AE. Effects of hormonal contraception and the menstrual cycle on fatigability and recovery from an anaerobic exercise test. J Strength Cond Res 38(7): 1256-1265, 2024-This study sought to evaluate the effects of oral contraceptive (OC) and hormonal intrauterine device (H-IUD) use, compared with a eumenorrheic (EUM) cycle, on fatigability and recovery between hormone the phases. Peak power (PP), average power (AP), fatigue index (FI), blood lactate, vessel diameter, and blood flow (BF) were measured from a repeated sprint cycle test (10 × 6 seconds) in 60, healthy, active women (mean ± SD ; age: 26.5 ± 7.0 years, BMI: 22.5 ± 3.7 kg·m -2 ) who used monophasic OC (≥6 months; n = 21), had a H-IUD (≥6 months; n = 20), or had regular naturally occurring menstrual cycle (≥3 months) or had a nonhormonal IUD (EUM; n = 19). Subjects were randomly assigned to begin in either the low-hormone phase (LHP) or high-hormone phase (HHP) and were tested once in each phase. Separate univariate analyses of covariances assessed the change from HHP to LHP between the groups, covaried for progesterone, with significance set at p ≤ 0.05. All groups demonstrated similar changes in PP, AP, FI, blood lactate, vessel diameter, and BF between the phases ( p > 0.05). Although not significant, AP was higher in LHP for OC (Δ -248.2 ± 1,301.4 W) and EUM (Δ -19.5 ± 977.7 W) and higher in HHP for H-IUD (Δ 369.3 ± 1,123.0 W). Oral contraceptive group exhibited a higher FI (Δ 2.0%) and reduced blood lactate clearance (Δ 2.5%) in HHP. In recreationally active women, hormonal contraception and hormone phases may minimally impact fatigue and recovery. Individual elite female athletes may benefit from understanding hormonal contraception type as performance and recovery may slightly vary across the cycle.


Assuntos
Teste de Esforço , Ciclo Menstrual , Humanos , Feminino , Ciclo Menstrual/fisiologia , Ciclo Menstrual/efeitos dos fármacos , Adulto , Teste de Esforço/métodos , Adulto Jovem , Ácido Láctico/sangue , Contracepção Hormonal , Fadiga/fisiopatologia , Dispositivos Intrauterinos , Fadiga Muscular/efeitos dos fármacos , Fadiga Muscular/fisiologia
9.
Medicine (Baltimore) ; 103(16): e37843, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38640319

RESUMO

RATIONALE: The overall pregnancy rate in individuals with an intrauterine device (IUD) for contraception is <1%. If pregnancy occurs while an IUD is in place, there is a higher risk of an ectopic pregnancy. We report the case of a woman with an IUD who was 7 weeks pregnant and experienced a spontaneous abortion 1 week later. PATIENT CONCERN: A 32-year-old woman presented to our outpatient department with intermittent vaginal staining for several days. DIAGNOSES: She was 7 weeks pregnant and had an IUD in place for over 4 years. A vaginal examination revealed no vaginal bleeding and no blood clots; however, a parous cervix was observed. The IUD string was not visible. Transvaginal ultrasonography revealed a gestational sac in the uterine cavity, with a fetal pole and a crown-rump length of 11.4 mm. The fetal heart rate was 159 beats/min. The IUD was located in the retroplacental region. The bilateral adnexa appeared normal (right ovary, 2.9 cm; left ovary, 2.5 cm). The patient was diagnosed with an intrauterine pregnancy with an IUD in place and threatened abortion. INTERVENTIONS: Attempts to remove the IUD were abandoned due to its location, and conservative treatment was initiated with Utrogestan (100 mg) administered 3 times a day for 1 week. Bed rest was advised. OUTCOMES: Unfortunately, she experienced a complete abortion 1 week later. LESSONS: The novelty of this case report lies in the rare occurrence of an intrauterine pregnancy with a long-term IUD in place, the challenges posed by the IUD's specific location, and the complex management of threatened abortion in this context. Our case highlights the diagnostic management approach for intrauterine pregnancy with an IUD in place. Furthermore, it explores the impact of IUD location on pregnancy prognosis.


Assuntos
Aborto Espontâneo , Ameaça de Aborto , Dispositivos Intrauterinos , Gravidez Ectópica , Gravidez , Feminino , Humanos , Adulto , Aborto Espontâneo/etiologia , Dispositivos Intrauterinos/efeitos adversos , Gravidez Ectópica/etiologia , Anticoncepção
10.
Arch Gynecol Obstet ; 309(5): 2041-2046, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38478158

RESUMO

AIM: Familial Mediterranean fever (FMF) is the most common inherited autoinflammatory disease in the world. There are known triggers to initiate an FMF attack, yet potential effects of intrauterine devices (IUD) in women of reproductive age have not been evaluated before. METHOD: Consecutive female patients with FMF who ever used IUD over the age of 18 were enrolled. Female patients with FMF were sub grouped according to the type of IUD they use. FMF attack frequency, severity, duration, presence of dysmenorrhea, severity of dysmenorrhea, having attacks during menstruation before and after IUD use were questioned. Demographic and clinical data were collected from hospital database. RESULTS: When all patients with IUD use were evaluated, it was found that the frequency of attacks increased after IUD insertion at 3rd and 12th months (median [min-max] attack frequency at 3rd month, 1 (0-3) vs 1 (0-6), p = 0.002, median [min-max] attack frequency at 12th month, 2 (0-12) vs 3.5 (0-18), p = 0.028). Attack severity measured by VAS pain was also significantly increased. Attack duration and menstrual pain was similar before and after IUD use. Attack frequency at 3rd and 12th months, attack severity and menstrual pain was all increased significantly in Cu-IUD users, whereas none of these parameters deteriorated in LNG-IUD group. CONCLUSION: IUD use, especially Cu-IUD, may increase the frequency and severity of attacks in female patients with FMF. Clinicians may benefit from considering LGN-IUD if IUDs are preferred as contraception in women of childbearing age with FMF.


Assuntos
Anticoncepcionais Femininos , Febre Familiar do Mediterrâneo , Dispositivos Intrauterinos de Cobre , Dispositivos Intrauterinos , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Dismenorreia/etiologia , Febre Familiar do Mediterrâneo/complicações , Dispositivos Intrauterinos/efeitos adversos , Anticoncepção , Dispositivos Intrauterinos de Cobre/efeitos adversos
11.
FP Essent ; 538: 25-29, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38498326

RESUMO

Long-acting reversible contraceptives (LARCs) include progestin and copper intrauterine devices (IUDs) and progestin subdermal implants. LARCs may be the preferred for individuals who want a method that is highly effective and can last for several years, or for whom estrogen is contraindicated. LARCs should be offered using a shared decision-making approach, keeping in mind that historically these methods have been used coercively to control the reproductive choices of marginalized or disabled people. To ensure safe prescribing and reduce barriers to receiving LARCs, family physicians should be familiar with two evidence-based national contraceptive guidelines: the U.S. Medical Eligibility Criteria for Contraceptive Use (U.S. MEC) and the U.S. Selected Practice Recommendations for Contraceptive Use (U.S. SPR). Information about insertion, removal, potential complications, and expected adverse effects should be included when counseling patients about LARC options. Both types of LARC IUDs can safely be used for emergency contraception if inserted within 5 days of unprotected intercourse. Several oral emergency contraception drug options also are available.


Assuntos
Anticoncepção Pós-Coito , Dispositivos Intrauterinos , Feminino , Humanos , Progestinas , Anticoncepcionais Orais , Anticoncepção
13.
Contraception ; 135: 110421, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38518903

RESUMO

OBJECTIVES: Intrauterine device (IUD) users often encounter barriers to desired removal. Self-removal, while previously found to be successful only 19% of the time, may mitigate these obstacles. Our primary objective was to evaluate the effectiveness of our previously developed IUD self-removal guide. Our secondary objectives were to evaluate the acceptability of the guide and characterize the self-removal process. STUDY DESIGN: This was a randomized controlled trial comparing IUD self-removal success rates with and without a guide. Participants selected a clinical or nonclinical setting for self-removal. The primary outcome was the rate of successful IUD self-removal. Covariates of interest included demographic characteristics, parity, body mass index, and attempted removal setting. RESULTS: Of the 116 participants, 35 (30%) successfully removed their IUDs, 20 (32%) randomized to the guide, and 15 (28%) randomized to no guide (p = 0.7). While our guide was not associated with increased successful self-removal, the majority (97%) of those randomized to it reported it to be helpful. Those who selected a nonclinical setting (80%) were more successful at self-removal (35% vs 9%, p = 0.01). Most participants would recommend IUD self-removal to a friend (68%) and attempt again with a future IUD (80%). CONCLUSIONS: The proportion of participants who successfully removed their IUDs was higher than previously shown, with or without the use of our guide. Our inclusion of a nonclinical setting was novel, in which the proportion of successful self-removal was significantly higher. Providers should consider discussion of IUD self-removal, with a reasonable expectation about the likelihood of success, as a means of increasing reproductive autonomy. IMPLICATIONS: IUD self-removal was feasible and acceptable.


Assuntos
Dispositivos Intrauterinos , Humanos , Feminino , Adulto , Remoção de Dispositivo/métodos , Adulto Jovem , Autocuidado/métodos
14.
Contraception ; 135: 110439, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38552820

RESUMO

OBJECTIVE: The majority of intrauterine devices (IUDs) inserted in China are tailless, requiring intrauterine manipulations for removal and causing pain. This study aimed to investigate the analgesic efficacy of lidocaine injection into a novel disposable injectable cervical dilator for IUD removal procedures. STUDY DESIGN: A double-blinded, placebo-controlled, randomized clinical trial was conducted with women aged 18-65 years old requesting outpatient IUD removal. The study randomly assigned participants to either lidocaine (injecting 5 ml of 2% lidocaine into the injectable cervical dilator) or placebo (injecting 5 ml of normal saline into the device) group. All participants received a standardized paracervical block. The primary outcome was pain reported during IUD removal on a 100 mm Visual Analog Scale (VAS). Intention-to-treat were conducted to evaluate the analgesic effectiveness of injecting lidocaine into the injectable cervical dilators. RESULTS: We enrolled seventy-four eligible participants (37 in lidocaine group and 37 in placebo group). The results showed that the median intraoperative VAS score in the lidocaine group was lower than the placebo group (30.0 mm [IQR 20.0-46.0, n = 37] vs 46.0 mm [IQR 30.0-55.0, n = 37], p = 0.01. In subgroup analyses, among participants with IUD removal and without uterine manipulation and additional procedures, there was no statistically significant disparity observed in intraoperative VAS scores between the lidocaine and placebo group (15.0 mm [IQR 10.0-27.5, n = 8] vs 20.0 mm [IQR 20.0-40.0, n = 6]), p = 0.28). Among participants with an IUD removal necessitating intrauterine manipulations and without additional procedures, showing lower intraoperative VAS scores in lidocaine group (25.0 mm [IQR 15.0-40.5, n = 17]) compared to placebo group (46.0 mm [IQR 38.5-50.0, n = 23]), p < 0.01. Among participants with additional procedures in addition to IUD removal, there was no statistically significant disparity observed in intraoperative VAS scores between the lidocaine and placebo group (41.0 mm [IQR 32.5-57.5, n = 12] vs 45.0 mm [IQR 22.5-69.0, n = 8]), p = 0.97). CONCLUSIONS: Injecting lidocaine into the novel disposable injectable cervical dilator for cervix dilation can significantly reduce pain during an IUD removal, particularly in patients necessitating intrauterine manipulations during IUD removal. IMPLICATIONS: When we have to perform intrauterine manipulations to remove an IUD, surgical pain and narrow cervical canal undoubtedly affect the implementation of the procedure. Injecting lidocaine into the injectable cervical dilator can achieve local anesthesia while dilating the cervix, and might reduce the choice of general anesthesia for IUD removal.


Assuntos
Anestésicos Locais , Remoção de Dispositivo , Dispositivos Intrauterinos , Lidocaína , Humanos , Lidocaína/administração & dosagem , Feminino , Adulto , Anestésicos Locais/administração & dosagem , Método Duplo-Cego , Adulto Jovem , Pessoa de Meia-Idade , Medição da Dor , Dor Processual/prevenção & controle , Dor Processual/etiologia , Adolescente , Equipamentos Descartáveis , China , Injeções
15.
Arch Gynecol Obstet ; 309(6): 2709-2718, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38517507

RESUMO

PURPOSE: To examine the utilization and characteristics related to the use of hysteroscopy at the time of endometrial evaluation for endometrial hyperplasia in the outpatient surgery setting. METHODS: This cross-sectional study queried the Healthcare Cost and Utilization Project's Nationwide Ambulatory Surgery Sample. The study population was 3218 patients with endometrial hyperplasia who underwent endometrial evaluation from January 2016 to December 2019. Performance and clinical characteristics of hysteroscopic endometrial evaluation were assessed with multivariable binary logistic regression models. RESULTS: A total of 2654 (82.5%) patients had hysteroscopic endometrial tissue evaluation. Patients with postmenopausal bleeding, heavy menstrual bleeding, and polycystic ovary syndrome were more likely to undergo hysteroscopic endometrial evaluation in multivariable analysis (all, adjusted-P < 0.001). Uterine injury occurred in 4.9 per 1000 hysteroscopic endometrial evaluations; none had uterine injury in the non-hysteroscopy cohort. Among the 2654 patients who had hysteroscopic endometrial evaluation, 106 (4.0%) patients had intrauterine device insertion at surgery, and the utilization increased from 2.9 to 5.8% during the study period (P-trend < 0.001). Younger age, more recent year surgery, and obesity were independently associated with increased utilization of intrauterine device insertion at hysteroscopic endometrial evaluation (all, adjusted-P < 0.05). Among 2023 reproductive-age patients with endometrial hyperplasia, 1666 (82.4%) patients underwent hysteroscopic endometrial evaluation. On multivariable analysis, patients with heavy menstrual bleeding were more likely to have hysteroscopic endometrial evaluation (adjusted-P < 0.05). Intrauterine device insertion increased from 3.7% in 2016 to 8.0% in 2019 (P-trend = 0.007). CONCLUSION: This nationwide analysis suggests that the insertion of intrauterine devices at the time of hysteroscopic endometrial tissue evaluation for endometrial hyperplasia is increasing among reproductive-age population.


Assuntos
Hiperplasia Endometrial , Histeroscopia , Dispositivos Intrauterinos , Humanos , Feminino , Hiperplasia Endometrial/cirurgia , Estudos Transversais , Pessoa de Meia-Idade , Adulto , Dispositivos Intrauterinos/efeitos adversos , Endométrio/patologia , Endométrio/cirurgia , Menorragia/etiologia , Menorragia/cirurgia
16.
Arch Gynecol Obstet ; 309(5): 2057-2062, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38492083

RESUMO

PURPOSE: The objective of this study is to assess the correlation between bleeding irregularities and the accurate placement of the intrauterine device (IUD) device in the uterine cavity, determined through transvaginal ultrasonography and hysteroscopy. In addition, the study aims to examine the cytokine profile in the uterine cavity and serum of patients experiencing bleeding irregularities after the insertion of nonhormonal IUDs. METHODS: A prospective cohort study was conducted at a single tertiary medical center, wherein patients experiencing intermenstrual bleeding and spotting after the insertion of nonhormonal IUDs were enrolled. The study involved hysteroscopic and sonographic assessments of the uterine cavity and IUD placement, along with the analysis of blood and uterine cavity cytokine profiles. RESULTS: During the period between July 2019 and February 2020, a total of eight patients who experienced intermenstrual bleeding and spotting after the insertion of nonhormonal IUDs were enrolled the study. One case was excluded since a progestative device was detected by ultrasound. Out of the five cases that underwent a thorough ultrasonographic assessment, three cases (60%) showed an embedded IUD. However, these findings were excluded by the hysteroscopic evaluation. CONCLUSION: The results suggest that ultrasonographic assessment may lead to an overdiagnosis of IUD mispositioning compared to hysteroscopy. In addition, both ultrasound and hysteroscopy have limitations in diagnosing the cause of bleeding in most cases. The role of local reactive inflammatory cytokines should be further studied.


Assuntos
Dispositivos Intrauterinos , Menorragia , Metrorragia , Gravidez , Humanos , Feminino , Histeroscopia , Menorragia/diagnóstico por imagem , Menorragia/etiologia , Estudos Prospectivos , Hemorragia , Ultrassonografia , Citocinas
17.
Scott Med J ; 69(2): 37-44, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38449359

RESUMO

BACKGROUND AND AIM: This study was carried out to determine the effect of the use of "virtual reality glasses," on anxiety, pain, and satisfaction level in order to reduce anxiety and pain during intrauterine device (IUD) insertion, which is a painful and stressful procedure for women and to divert attention to increase satisfaction. METHODS: This randomized controlled study in the gynecology clinic of a state hospital with 80 women who were accepted to participate in the study. Data were collected using structured patient information form, numerical pain rating scale, state-trait anxiety inventory, patient satisfaction evaluation form, and virtual reality glasses. RESULTS: Post-procedural pain scores in the control group after IUD application were higher than post-procedural pain in the virtual reality group. Measurements of post-procedure anxiety in the control group were higher than measurements of post-procedural in the virtual reality group. Satisfaction levels of women with virtual reality glasses during IUD insertion were also found to be high. CONCLUSIONS: It was determined that the use of virtual reality glasses, one of the methods of distraction during IUD insertion, was effective in reducing pain and anxiety and increasing patient satisfaction.


Assuntos
Ansiedade , Dispositivos Intrauterinos , Medição da Dor , Satisfação do Paciente , Realidade Virtual , Humanos , Feminino , Ansiedade/prevenção & controle , Ansiedade/etiologia , Adulto , Dor Processual/prevenção & controle , Dor Processual/etiologia , Dor/prevenção & controle , Dor/etiologia , Dor/psicologia , Adulto Jovem , Manejo da Dor/métodos
18.
Medicine (Baltimore) ; 103(7): e33857, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38363896

RESUMO

RATIONALE: Uterine perforation is a serious complication of intrauterine contraceptive device (IUD) placement. However, as complete uterine perforation and extrauterine migration may remain asymptomatic, thorough localization of the IUD is important prior to reinsertion. PATIENT CONCERNS: A 33-year-old patient who has had 4 IUD insertions, wherein the location of the first IUD (inserted 14 years ago) was not identified prior to reinsertion and replacement of the subsequent three. She presented to hospital with a 6-month history of abdominal pain. Pelvic ultrasonography (US), radiography, hysteroscopy and laparoscopy examinations confirmed that a retained migrated IUD in the right broad ligament. DIAGNOSIS: Uterine perforation, IUD migration to the broad ligament. INTERVENTIONS: The patient underwent hysteroscopy and laparoscopy. OUTCOMES: Both IUDs were successfully removed without any complications.


Assuntos
Ligamento Largo , Migração de Dispositivo Intrauterino , Dispositivos Intrauterinos , Perfuração Uterina , Feminino , Humanos , Adulto , Perfuração Uterina/diagnóstico por imagem , Perfuração Uterina/etiologia , Migração de Dispositivo Intrauterino/efeitos adversos , Dispositivos Intrauterinos/efeitos adversos , Radiografia
19.
BMC Vet Res ; 20(1): 46, 2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38310284

RESUMO

BACKGROUND: Intrauterine devices (IUD) are used in the veterinary practice as the non-pharmacological method of oestrus suppression in mares. When placed in the uterus, IUD create a physical contact with the endometrium that mimics the presence of an equine embryo. However, the mechanism of their action has not been fully elucidated. The objective of the present study was to examine the effect of mechanical stimulation of IUD on mare`s endometrium in both in vitro and in vivo study. For this purpose, we demonstrated the effect of IUD on prostaglandin (PG) F2α and PGE2 secretion, and mRNA transcription of genes involved in PG synthesis pathway in equine endometrial cells in vitro. In the in vivo study, we aimed to compare short-term effect of IUD inserted on day 0 (oestrus) with day 5-6 post-ovulation (the specific time when embryo reaches uterus after fertilization) on PG secretion from equine endometrium. To determine the long-term effect on PG synthase mRNA transcription, a single endometrial biopsy was taken only once within each group of mares at certain time points of the estrous cycle from mares placement with IUD on days 0 or 5-6 post-ovualtion. RESULTS: We showed for the first time that the incubation of the endometrial cells with the presence of IUD altered the pattern of PG synthase mRNA transcription in equine epithelial and stromal endometrial cells. In vivo, in mares placement with IUD on day 0, PGE2 concentrations in blood plasma were upregulated between 1 and 6, and at 10 h after the IUD insertion, compared with the control mares (P < 0.05). Moreover, the decrease of PTGFS mRNA transcription on day 16- 18, associated with an elevation in PTGES mRNA transcription on day 20 -21 of the estrous cycle in endometrial biopsies collected from mares placement with IUD on days 5-6 suggest an antiluteolytic action of IUD during the estrous cycle. CONCLUSION: We conclude that the application of IUD may mimic the equine conceptus presence through the physical contact with the endometrium altering PG synthase transcription, and act as a potent modulator of endometrial PG secretion both in vitro and in vivo.


Assuntos
Dinoprostona , Dispositivos Intrauterinos , Cavalos/genética , Animais , Feminino , Dinoprostona/metabolismo , Prostaglandina-Endoperóxido Sintases/genética , Prostaglandinas F/metabolismo , Endométrio/metabolismo , Dispositivos Intrauterinos/veterinária , RNA Mensageiro/genética , RNA Mensageiro/metabolismo
20.
Contraception ; 133: 110399, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38369271

RESUMO

OBJECTIVE: To evaluate differences based on intrauterine device (IUD) frame geometry in force, and stress, and strain at the stem/arms junction during simulated IUD removal. STUDY DESIGN: We manufactured injection-molded frame models for three Nova-T IUDs (Mirena [model M]; Liletta [model L]; Kyleena [model K]) and a Tatum-T IUD (Paragard [model P]) at two-times scaling. We created a custom fixture to simulate the uterus and used a screw-driven machine to pull models at various displacement rates through the 10 cm fixture cavity to measure force and strain and calculate stress at the IUD stem/arms junction. We tested models at 30 mm/min and higher displacement rates for exploratory analyses. We used Mann-Whitney U test for statistical testing. RESULTS: We completed testing at 30 mm/min using five of each Nova-T model and nine model P samples. Resistance against the cavity walls created significantly more force on model P (11.83, interquartile range [IQR] 11.61-12.31) than any Nova-T model samples (p < 0.001). The smaller model K created slightly more median stress (MPa) than the larger model M (0.36 [IQR 0.33-0.38] and 0.79 [IQR 0.76-0.80], respectively, p = 0.008); model P samples generated significantly more median stress than other models (1.70 [IQR 1.67-1.77], p < 0.001). Strain plots demonstrated permanent deformation for some samples during IUD removal simulation. We tested 20 samples at various higher displacement rates up to 2500 mm/min, with stress notably increasing for model P samples with increasing rates. No fractures occurred. CONCLUSIONS: Force and stress at the stem/arms junction are higher with Tatum-T-shaped compared to Nova-T-shaped IUD models under the same testing conditions, and a higher speed of extraction causes more stress. IMPLICATIONS: Sharp corners create vulnerability under static and fatigue loading in structural components due to increased local stresses. Our findings suggest that IUDs with Tatum-T frames should be removed slowly to minimize the stress at the stem/arms junction. Future studies can provide more information if performed with commercially available products.


Assuntos
Dispositivos Intrauterinos de Cobre , Dispositivos Intrauterinos , Feminino , Humanos , Levanogestrel , Útero , Remoção de Dispositivo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA