Resultados 1 - 20 de 7.434
Filtrar
1.
Artigo em Chinês | MEDLINE | ID: mdl-38973048

RESUMO

Objective:To investigate the therapeutic effect of ß-tricalcium phosphate in mastoid cavity obliteration for middle ear cholesteatoma under endoscope. Methods:Sixty patients with middle ear cholesteatoma admitted to our department from September 2021 to March 2022 were included in this study. The observation group(n=30) received ß-tricalcium phosphate during mastoid cavity obliteration. The control group(n=30) received autologous tissue during mastoid cavity obliteration. Pure tone audiometry was performed before surgery and after surgery in both groups, and the air conduction thresholds of 500, 1 000, 2 000 and 4 000 Hz were recorded. The external acoustic meatus cross-sectional area within 1 cm of the external acoustic meatus opening was measured during the operation and after the operation. The differences of postoperative ear drying time, hearing change and mastoid cavity healing were compared between the two groups. Results:The duration of postoperative dry ear in the observation group was 2-14 weeks, with an average of (9.4±2.7) weeks, while that in the control group was 4-26 weeks, with an average of(16.0±5.7) weeks. The difference in dry ear time between the two groups was statistically significant(P<0.05). In the observation group, the threshold change was -19-27 dB, with an average of(6.4±10.7) dB, and in the control group, the threshold change was -9-17 dB, with an average of (4.7±7.1) dB. There was no significant difference in hearing change between the two groups(P>0.05). In the observation group, the cross-sectional area of 1 cm inside the ear canal opening was -5.9-8.2 mm², with an average of (-0.6±2.6) mm², and in the control group, the cross-sectional area of 1 cm inside the ear canal opening was -5.5-5.2 mm², with an average of (-0.4±2.3) mm². There was no significant difference in intraoperative cavity changes between the two groups(P>0.05). Conclusion:The application of ß-tricalcium phosphate to fill the mastoid cavity during the operation of endoscopic middle ear cholesteatoma has no adverse effect on the hearing of patients, can shorten the postoperative dry ear time, and results in good postoperative healing, which is worth promoting.


Assuntos
Fosfatos de Cálcio , Colesteatoma da Orelha Média , Processo Mastoide , Humanos , Fosfatos de Cálcio/uso terapêutico , Processo Mastoide/cirurgia , Colesteatoma da Orelha Média/cirurgia , Masculino , Feminino , Adulto , Endoscopia/métodos , Pessoa de Meia-Idade , Audiometria de Tons Puros , Resultado do Tratamento , Endoscópios
2.
J Robot Surg ; 18(1): 266, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38916651

RESUMO

The endoscopic control system has remained similar in design for many decades The remit of advanced therapeutic endoscopy continues to expand requiring precision control and high cognitive workloads. Robotic systems are emerging, but all still require bimanual control and expensive and large new systems. Eye tracking is an exciting area that can be used as an endoscope control system. This is a study to establish the feasibility of an eye-controlled endoscope and compare its performance and cognitive demand to use of a conventional endoscope. An eye gaze-control system consisting of eye-tracking glasses, customised software and a small motor unit was built and attached to a conventional endoscope. Twelve non-endoscopists used both the eye gaze system and a conventional endoscope to complete a benchtop task in a simulated oesophagus and stomach. Completion of tasks was timed. Subjective feedback was collected from each participant on task load using the NASA Task Load Index. Participants were significantly quicker completing the task using iGAZE2 vs a conventional endoscope (65.02 ± 16.34s vs 104.21 ± 51.31s, p = 0.013) Participants were also significantly quicker completing retroflexion using iGAZE2 vs a conventional endoscope (8.48 ± 3.08 vs 11.38 ± 5.36s, p = 0.036). Participants reported a significantly lower workload (raw NASA-TLX score) when using iGAZE2 vs the conventional endoscope (152.1 ± 63.4 vs 319.6 ± 81.6, p = 0.0001) (Fig. 7). Users found iGAZE2 to have a significantly lower temporal demand, mental demand, effort, mental demand, physical demand, and frustration level. The eye gaze system is an exciting, small, and retrofittable system to any endoscope. The system shows exciting potential as a novel endoscopic control system with a significantly lower workload and better performance in novices suggesting a more intuitive control system.


Assuntos
Tecnologia de Rastreamento Ocular , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Masculino , Desenho de Equipamento , Feminino , Adulto , Análise e Desempenho de Tarefas , Estudos de Viabilidade , Endoscopia/métodos , Endoscópios
3.
Clin Nurse Spec ; 38(4): 189-192, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38889060

RESUMO

PURPOSE/OBJECTIVES: The Centers for Disease Control and Prevention has highlighted the strong association between healthcare-associated infections and the reprocessing of flexible endoscopes. This process improvement project provided an evidence-based workflow analysis of pleuravideoscope reprocessing to validate and implement safe practices in the pulmonary clinic and sterile processing department. DESCRIPTION OF THE PROJECT/PROGRAM: A multidisciplinary team created an audit tool to complete infection control risk assessment using Lean Six Sigma methodology. OUTCOME: The risk assessment identified gaps in clinical practice, prompting corrective measures using a shared decision-making approach. The organization updated standard operating procedures, provided training and competency assessments, and purchased single-use pleuravideoscopes. These initiatives addressed the deficiencies and reinforced a culture of continuous process improvement and patient safety. CONCLUSION: Multidisciplinary teams should perform comprehensive reviews of facility processes and assess the risks related to infection control to identify optimal pleuravideoscope workflows for the healthcare institution. The involvement of a clinical nurse specialist is advantageous, as they possess the expertise necessary to facilitate collaborative efforts among team members spanning various departments. By leveraging the insights and skills of diverse professionals, healthcare organizations can optimize their reprocessing programs and enhance patient safety.


Assuntos
Esterilização , Humanos , Enfermeiros Clínicos , Endoscópios/microbiologia , Equipe de Assistência ao Paciente/organização & administração , Infecção Hospitalar/prevenção & controle , Controle de Infecções , Contaminação de Equipamentos/prevenção & controle , Pesquisa em Avaliação de Enfermagem
4.
IEEE J Transl Eng Health Med ; 12: 499-507, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38899143

RESUMO

OBJECTIVE: Variable-view rigid scopes offer advantages compared to traditional angled laparoscopes for examining a diagnostic site. However, altering the scope's view requires a high level of dexterity and understanding of spatial orientation. This requires an intuitive mechanism to allow an operator to easily understand the anatomical surroundings and smoothly adjust the scope's focus during diagnosis. To address this challenge, the objective of this work is to develop a mechanized arm that assists in visualization using variable-view rigid scopes during diagnostic procedures. METHODS: A system with a mechanized arm to maneuver a variable-view rigid scope (EndoCAMeleon - Karl Storz) was developed. A user study was conducted to assess the ability of the proposed mechanized arm for diagnosis in a preclinical navigation task and a simulated cystoscopy procedure. RESULTS: The mechanized arm performed significantly better than direct maneuvering of the rigid scope. In the preclinical navigation task, it reduced the percentage of time the scope's focus shifted outside a predefined track. Similarly, for simulated cystoscopy procedure, it reduced the duration and the perceived workload. CONCLUSION: The proposed mechanized arm enhances the operator's ability to accurately maneuver a variable-view rigid scope and reduces the effort in performing diagnostic procedures.Clinical and Translational Impact Statement: The preclinical research introduces a mechanized arm to intuitively maneuver a variable-view rigid scope during diagnostic procedures, while minimizing the mental and physical workload to the operator.


Assuntos
Desenho de Equipamento , Humanos , Cistoscopia/métodos , Cistoscopia/instrumentação , Endoscópios
6.
Neurocirugia (Astur : Engl Ed) ; 35(4): 221-224, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38801859

RESUMO

The superior canal dehiscence syndrome is a pathology that affects the arcuate eminence creating a "third window" between the inner ear and the middle fossa. This condition can lead to symptoms such as hearing loss, autophony, or sound-induced vertigo. Traditionally, surgical treatment has been performed by microscope-assisted temporal craniotomy, but when the dehiscence is in the medial part of the arcuate eminence the bone defect may not be seen. We present case series treated at our institution diagnosed of superior canal dehiscence syndrome involving the medial slope of the arcuate eminence. During surgery, the bone defect could not be visible with traditional microscopic techniques. Nonetheless, by introducing the endoscope with the 0º and 30º optics, the dehiscence could be clearly observed and treated correctly. Our results show a clinical improvement without side effects or complications in the patients undergoing this technique. Endoscope-assisted surgery is a safe procedure and provides a better visualization of medial defects.


Assuntos
Deiscência do Canal Semicircular , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Deiscência do Canal Semicircular/cirurgia , Idoso , Adulto , Endoscopia/métodos , Canais Semicirculares/cirurgia , Endoscópios , Craniotomia/métodos
7.
J Orthop Surg Res ; 19(1): 254, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649974

RESUMO

BACKGROUND: The one-hole split endoscopy (OSE) was first proposed and clinically applied in China in 2019. The aim of this study was to compare the clinical efficacy of one-hole split endoscopy (OSE) and unilateral biportal endoscopy (UBE) for treating lumbar spinal stenosis (LSS). METHODS: One hundred sixty patients with LSS who met the inclusion from November 2020 to August 2022 were analyzed and divided into OSE and UBE groups. The propensity score matching (PSM) method was used to adjust the imbalanced confounding variables between the two groups. After matching, surgical outcomes were recorded, and clinical data, including functional scores and imaging findings, were compared. Functional scores included the visual analog scale of leg pain (VAS-LP) and back pain (VAS-BP), the Japanese Orthopedic Association score (JOA), and the Oswestry Disability Index (ODI). Imaging data included dural sac cross-sectional area (DCSA), lumbar range of motion (ROM), and sagittal translation (ST). RESULTS: After PSM, 104 LSS patients were included in the study, and all covariates were well-balanced between the two groups. Among the matched patients, the OSE showed advantages over the UBE regarding operative time (62.42 ± 4.86 vs. 68.96 ± 4.56) and incision length (2.30 ± 0.14 vs. 2.70 ± 0.15) (P < 0.001). However, differences between the two groups in intraoperative blood loss, hospital length of stay, and complication rates were not statistically significant (P > 0.05). There was no statistically significant difference regarding VAS-BP, VAS-LP, JOA, and ODI between the two groups (P > 0.05). However, all clinical and functional scores significantly improved postoperatively (P < 0.05). Postoperative DCSA of both groups was significantly found to be improved (P < 0.05), ROM and ST remained within the normal range, and no cases of lumbar instability were recorded. According to the modified MacNab criteria, the excellent and good rates in the OSE and UBE groups were 94.23% and 90.38%, respectively, with no statistically significant difference (P = 0.713). CONCLUSION: OSE is an alternative technique to UBE for the treatment of LSS, with similar satisfactory clinical outcomes, shorter operative time, and smaller incision length. Further studies are needed for long-term efficacy.


Assuntos
Endoscopia , Vértebras Lombares , Pontuação de Propensão , Estenose Espinal , Humanos , Estenose Espinal/cirurgia , Estenose Espinal/diagnóstico por imagem , Masculino , Feminino , Vértebras Lombares/cirurgia , Vértebras Lombares/diagnóstico por imagem , Pessoa de Meia-Idade , Estudos Retrospectivos , Endoscopia/métodos , Idoso , Resultado do Tratamento , Endoscópios
8.
J Hosp Infect ; 149: 36-45, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38649121

RESUMO

BACKGROUND: Contamination rates reported in the literature for patient-ready flexible endoscopes vary from 0.4% to 49%. Unfortunately, the comparison and interpretation of these results is almost impossible since several factors including sampling and culturing methods, target levels for contamination, or definition of indicator micro-organisms vary widely from one study to the other. AIM: To compare the efficacy of six duodenoscope sampling and culturing methods by means of extraction efficacy comparison, while at the same time identifying key parameters that provide optimal microbial recovery. METHODS: The duodenoscope sample extraction efficacy of each method was assessed using the repetitive recovery method described in ISO 11737-1: 2018. FINDINGS: Mean overall bioburden extraction efficacy varied from 1% for the Australian method to 39% for the French one. The lowest endoscope sample extraction efficacy was associated with the absence of any neutralizer, friction, or tensioactive agent, and when only a small portion of the sampling solution collected was inoculated on to culture media. The efficacy of the sampling and culturing methods also varied according to the nature of micro-organisms present in the endoscope, and the time between sampling and culturing. CONCLUSION: This study supports the need for a harmonized and standardized sampling and culturing method for flexible endoscopes.


Assuntos
Contaminação de Equipamentos , Manejo de Espécimes , Humanos , Manejo de Espécimes/métodos , Manejo de Espécimes/instrumentação , Contaminação de Equipamentos/prevenção & controle , Bactérias/isolamento & purificação , Bactérias/classificação , Técnicas Microbiológicas/métodos , Endoscópios/microbiologia , Duodenoscópios/microbiologia
9.
Acta Med Indones ; 56(1): 84-92, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38561887

RESUMO

Corrosive injuries (CI) become medical problems related complications include esophageal, pyloric stricture and squamous cell carcinoma, physical and quality of life. Endoscopic (ED) dilatation is primary therapy. The ultrathin endoscope-assisted method is potentially safe and useful in avoiding technical failure. Describe clinical outcomes of ED ED-related CI including successful, refractory, recurrent, and complications-related procedures. Case series study of esophageal and/or pyloric stricture patients after CI who underwent dilatation at Soetomo General Hospital (July 2018 - July 2022). One - biweekly ED using Through The Scope (TTS) balloon or Savary Bougie dilator. The target diameter is 14mm. Fifteen patients with stricture-related CI. Eleven patients underwent ED with a total of 73 procedures. Mean age 31,45 years, predominantly male patients (6), suicide attempt (7), acid agent (9), located at esophagus (3), pylorus (3), or both (5). Number of esophageal dilatation to achieve the target of 14 mm was 1-2 and 2-15 procedures for simple and complex stricture. Five esophageal strictures were successfully dilated but 2 patients were recurrent and 3 cases were refractory to ED. Pyloric dilatation resulted in a lower success rate. Recurrent and refractory cases were 5 and 3 patients respectively. ED with ultrathin endoscope method is useful for traversing guidewire during ED. Ongoing inflammation and fibrosis were linked to recurrent and refractory stricture.


Assuntos
Queimaduras Químicas , Cáusticos , Estenose Esofágica , Humanos , Masculino , Feminino , Cáusticos/toxicidade , Constrição Patológica , Esofagoscopia/efeitos adversos , Esofagoscopia/métodos , Dilatação/efeitos adversos , Dilatação/métodos , Qualidade de Vida , Resultado do Tratamento , Estenose Esofágica/induzido quimicamente , Estenose Esofágica/terapia , Estenose Esofágica/complicações , Endoscópios/efeitos adversos , Queimaduras Químicas/terapia , Queimaduras Químicas/complicações
13.
Adv Sci (Weinh) ; 11(19): e2400980, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38482737

RESUMO

Endoscopes navigate within the human body to observe anatomical structures with minimal invasiveness. A major shortcoming of their use is their narrow field-of-view during navigation in large, hollow anatomical regions. Mosaics of endoscopic images can provide surgeons with a map of the tool's environment. This would facilitate procedures, improve their efficiency, and potentially generate better patient outcomes. The emergence of magnetically steered endoscopes opens the way to safer procedures and creates an opportunity to provide robotic assistance both in the generation of the mosaic map and in navigation within this map. This paper proposes methods to autonomously navigate magnetic endoscopes to 1) generate endoscopic image mosaics and 2) use these mosaics as user interfaces to navigate throughout the explored area. These are the first strategies, which allow autonomous magnetic navigation in large, hollow organs during minimally invasive surgeries. The feasibility of these methods is demonstrated experimentally both in vitro and ex vivo in the context of the treatment of twin-to-twin transfusion syndrome. This minimally invasive procedure is performed in utero and necessitates coagulating shared vessels of twin fetuses on the placenta. A mosaic of the vasculature in combination with autonomous navigation has the potential to significantly facilitate this challenging surgery.


Assuntos
Endoscopia , Humanos , Endoscopia/métodos , Feminino , Transfusão Feto-Fetal/cirurgia , Magnetismo/métodos , Endoscópios , Gravidez , Procedimentos Cirúrgicos Robóticos/métodos
14.
Opt Express ; 32(5): 8308-8320, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38439489

RESUMO

Conventional photoacoustic endoscopy (PAE) is mostly for structural imaging, and its molecular imaging ability is quite limited. In this work, we address this issue and present the development of a flexible acoustic-resolution-based photoacoustic endoscopic (AR-PAE) probe with an outer diameter of 8 mm. This probe is driven by a micro-step motor at the distal end, enabling flexible and precise angular step control to synchronize with the optical parametric oscillator (OPO) lasers. This probe retains the high spatial resolution, high penetration depth, and spectroscopic imaging ability of conventional AR-PAE. Moreover, it is capable for background-free high-specific photoacoustic molecular imaging with a novel pump-probe detection technique, as demonstrated by the distribution visualizing of the FDA approved contrast agent methylene blue (MB) in an ex-vivo pig ileum. This proposed method represents an important technical advancement in multimodal PAE, and can potentially make considerable contributions across various biomedical fields.


Assuntos
Endoscópios , Imagem Molecular , Animais , Suínos , Análise Espectral , Meios de Contraste , Azul de Metileno
15.
Otol Neurotol ; 45(3): e256-e262, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38361307

RESUMO

OBJECTIVE: Tympanic membrane (TM) thickness is an important parameter for differentiation between a healthy and a pathologic TM. Furthermore, it is needed for modeling the middle ear function. Endoscopic optical coherence tomography (eOCT) provides the opportunity to measure the TM thickness of the entire TM in vivo. MATERIALS AND METHODS: A total of 27 healthy ears were examined by eOCT. The system uses a light source with a central wavelength of 1,300 nm. The endoscope with an outer diameter of 3.5 mm provides a field of view of 10 mm and a working distance of 10 mm. Thickness measurements were carried out at 8 points on the TM. Additionally, the existing literature was analyzed, and a mean TM thickness value was determined. RESULTS: The mean thickness of the TM over all measurement points of the pars tensa was 120.2 µm, and the pars flaccida was significantly thicker with a mean thickness of 177.9 µm. Beyond that, there were no significant differences between the single quadrants. The mean TM thickness in the literature was 88.8 µm. DISCUSSION: EOCT provides the possibility for in vivo thickness determination of the TM. The mean thickness seems to be higher than in the previous studies, which were mostly carried out ex vivo. Our study takes the three-dimensional refraction into account and provides a method for the refraction correction.


Assuntos
Tomografia de Coerência Óptica , Membrana Timpânica , Humanos , Membrana Timpânica/patologia , Tomografia de Coerência Óptica/métodos , Endoscópios
16.
J Biomed Opt ; 29(2): 020502, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38361504

RESUMO

Significance: There has been significant interest in the development of miniature photoacoustic imaging probes for a variety of clinical uses, including the in situ assessment of tumors and minimally invasive surgical guidance. Most of the previously implemented probes are either side viewing or operate in the optical-resolution microscopy mode in which the imaging depth is limited to ∼1 mm. We describe a forward-viewing photoacoustic probe that operates in tomography mode and simultaneously provides white light video images. Aim: We aim to develop a dual-modality endoscope capable of performing high-resolution PAT imaging and traditional white light videoscopy simultaneously in the forward-viewing configuration. Approach: We used a Fabry-Pérot ultrasound sensor that operates in the 1500 to 1600 nm wavelength range and is transparent in the visible and near infrared region (580 to 1250 nm). The FP sensor was optically scanned using a miniature MEMs mirror located at the proximal end of the endoscope, resulting in a system that is sufficiently compact (10 mm outer diameter) and lightweight for practical endoscopic use. Results: The imaging performance of the endoscope is evaluated, and dual-mode imaging capability is demonstrated using phantoms and abdominal organs of an ex vivo mouse including spleen, liver, and kidney. Conclusions: The proposed endoscope design offers several advantages including the high acoustic sensitivity and wide detection bandwidth of the FP sensor, dual-mode imaging capability, compact footprint, and an all-optical distal end for improved safety. The dual-mode imaging capability also offers the advantage of correlating the tissue surface morphology with the underlying vascular anatomy. Potential applications include the guidance of laparoscopic surgery and other interventional procedures.


Assuntos
Técnicas Fotoacústicas , Camundongos , Animais , Técnicas Fotoacústicas/métodos , Endoscópios , Ultrassonografia , Microscopia , Endoscopia
17.
Postgrad Med J ; 100(1184): 407-413, 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38330500

RESUMO

PURPOSE: Retroflexed endoscopic rubber band ligation (ERBL) for treating Grade II and III internal hemorrhoids using disposable endoscopes has not been previously assessed. We therefore compared the safety and effectiveness of ERBL for internal hemorrhoids using novel disposable endoscopes versus traditional reusable endoscopes. METHODS: This prospective randomized controlled trial involved 42 patients who underwent ERBL for Grade II and III internal hemorrhoids using either a disposable endoscope (n = 21) or a reusable endoscope (n = 21). Safety was assessed by the incidence of equipment failure, device-related adverse events, and in-procedure stability of vital signs. Effectiveness was assessed by the postoperative therapeutic effect, feasibility of retroflexed ERBL, and incidence of complications. RESULTS: In terms of safety, no life-threatening events, equipment failure, or device-related adverse effects occurred during the procedures in either group. The rate of diastolic blood pressure stability was significantly different between the two groups (P = .049), but the rates of systolic blood pressure and heart rate stability were similar. In terms of effectiveness, the therapeutic effects on postoperative Day 30 were similar in both groups. Image clarity and endoscopic flexibility in the disposable endoscope group were mildly inferior to those in the reusable endoscope group, but without statistical significance. Matching between the endoscope and ligating device was 100% in both groups. The incidence of complications on postoperative Days 1 and 10 was not significantly different between the two groups. CONCLUSION: Compared with reusable endoscopes, disposable endoscopes are equally safe, feasible, and reliable in ERBL for internal hemorrhoids.


Assuntos
Equipamentos Descartáveis , Hemorroidas , Humanos , Hemorroidas/cirurgia , Ligadura/instrumentação , Ligadura/métodos , Feminino , Masculino , Projetos Piloto , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Endoscópios , Adulto , Idoso , Endoscopia/métodos
18.
Am J Infect Control ; 52(6): 635-643, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38408542

RESUMO

BACKGROUND: Outbreaks linked to inadequate endoscope drying have infected numerous patients, and current standards and guidelines recommend at least 10 minutes of forced air for drying channels. This study evaluated a new forced-air drying system (FADS) for endoscopes. METHODS: Drying was assessed using droplet detection cards; visual inspection of air/water connectors, suction connectors, and distal ends; and borescope examinations of endoscope interiors. Assessments were performed after automated endoscope reprocessor (AER) alcohol flush and air purge cycles and after 10-minute FADS cycles. RESULTS: Researchers evaluated drying during encounters with 22 gastroscopes and 20 colonoscopes. After default AER alcohol and air purge cycles, 100% (42/42) of endoscopes were still wet. Substantial fluid emerged from distal ends during the first 15 seconds of the FADS cycle, and droplets also emerged from air/water and suction connectors. Following FADS cycle completion, 100% (42/42) were dry, with no retained fluid detected by any of the assessment methods. CONCLUSIONS: Multiple endoscope ports and channels remained wet after AER cycles intended to aid in drying but were dry after the FADS cycle. This study reinforced the need to evaluate the effectiveness of current drying practices and illustrated the use of practical tools in a real-world setting.


Assuntos
Endoscópios , Humanos , Endoscópios/microbiologia , Dessecação/métodos , Desinfecção/métodos , Desinfecção/normas , Contaminação de Equipamentos/prevenção & controle
19.
Artigo em Chinês | MEDLINE | ID: mdl-38297855

RESUMO

Objective:To explore the feasibility of using self-made visual throat forceps to remove hypopharyngeal foreign bodies. Methods:The throat forceps were combined with the endoscope and connected to a monitor via a data cable resulting in a visual throat forceps apparatus. This device was utilized to examine and treat the hypopharyngeal foreign bodies. Results:Among 53 patients, foreign bodies were detected in 51,with 48 cases involving hypopharyngeal foreign bodies. All were successfully extracted using the visual throat forceps. Three cases, diagnosed as esophageal foreign bodies by electronic gastroscopy, were treated using the same method. Conclusion:Visual throat forceps can be used to examine the hypopharynx and remove foreign bodies. It has the advantages of simple operation, rapid operation, and high success rate of foreign body removal from the hypopharynx. It is worthy of clinical application.


Assuntos
Corpos Estranhos , Hipofaringe , Humanos , Hipofaringe/cirurgia , Faringe/cirurgia , Endoscópios , Instrumentos Cirúrgicos , Corpos Estranhos/diagnóstico
20.
Artigo em Chinês | MEDLINE | ID: mdl-38297862

RESUMO

Objective:To compare the application of endoscope and microscope in all kinds of stapes surgeries. Methods:Fifty-nine stapes surgeries have been collected from April 2020 to May 2023 in Senior Department of Otolaryngology Head and Neck Surgery, Chinese PLA General Hospital, Chinese PLA Medical School. Hearing level, hospital stay post-operation, times of hospital visit post-operation, etc. have been compared between the endoscopic group and microscopic group. Patients who were failed to place the stapes prosthesis because of the poor exposure of the oval window have been analyzed. Results:Otosclerosis was the most common diagnosis in both groups. There was 1(1/23) middle ear malformation in the endoscopic group and 5(5/36) middle ear malformations in the microscopic group. There were 2 Van Der Hover syndromes and 4 Treacher Collins syndromes in the microscopic group. In the endoscopic group ABG of 10 ears(43.5%) ≤ 10 dB, and ABG of 21 ears(91.3%) ≤20 dB.In the microscopic group ABG of 13 ears(41.9%) ≤ 10 dB, and ABG of 28 ears(90.3%) ≤ 20 dB. There was no statistic difference between 2 groups. Times of hospital visit post-operation in the endoscopic group was less than in the microscopic group(P<0.01). There was no facial palsy, tympanic perforation or profound sensorineural hearing loss in both groups. Conclusion:Endoscope is more suitable for patients who are evaluated with no severe stapes malformation, or less manipulation of drilling the bone. It could also reduce the hospital visit post-operation. Patients with narrow ear canal or severe middle ear malformation are recommended to perform the surgery with microscope, because it provides the chance of manipulation with 2-hands of surgeons.


Assuntos
Otosclerose , Cirurgia do Estribo , Humanos , Estribo , Orelha Média/cirurgia , Orelha Média/anormalidades , Otosclerose/diagnóstico , Endoscópios , Poliésteres , Estudos Retrospectivos , Resultado do Tratamento