Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 612
Filtrar
1.
N Z Med J ; 137(1600): 62-65, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39088810

RESUMO

AIM: The aim of this study was to follow the instruments' pathways and cost each segment to calculate whether reusable or disposable ophthalmic instruments offer better value for money for intravitreal injections. METHODS: The cycles and costs of reusable and single-use disposable instruments used for intravitreal injections were mapped out, including purchase costs, transport to and from the place of use, opening and disposal, sterilisation, replacement, salary costs of staff involved, etc. results: The cost of using reusable instruments for intravitreal injections (NZ$29.00) was lower than the cost of using disposable instruments ($30.51) by $1.51 per patient. CONCLUSIONS: Intravitreal injections performed with reusable instruments offer better value for money than when performed with disposable instruments. This equates to a beneficial financial saving just for this one low-complexity case. Such savings can multiply significantly when considering the instruments used in a wider variety of ophthalmic procedures. There are of course trade-offs between safety, quality, cost and sustainability.


Assuntos
Equipamentos Descartáveis , Reutilização de Equipamento , Injeções Intravítreas , Injeções Intravítreas/instrumentação , Injeções Intravítreas/economia , Equipamentos Descartáveis/economia , Humanos , Reutilização de Equipamento/economia , Nova Zelândia , Análise Custo-Benefício
2.
J Am Acad Orthop Surg ; 32(15): 705-711, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38861714

RESUMO

INTRODUCTION: Orthopaedic surgery is culpable, in part, for the excessive carbon emissions in health care partly due to the utilization of disposable instrumentation in most procedures, such as rotator cuff repair (RCR). To address growing concerns about hospital waste, some have considered replacing disposable instrumentation with reusable instrumentation. The purpose of this study was to estimate the cost and carbon footprint of waste disposal of RCR kits that use disposable instrumentation compared with reusable instrumentation. METHODS: The mass of the necessary materials and their packaging to complete a four-anchor RCR from four medical device companies that use disposable instrumentation and one that uses reusable instrumentation were recorded. Using the cost of medical waste disposal at our institution ($0.14 per kilogram) and reported values from the literature for carbon emissions produced from the low-temperature incineration of noninfectious waste (249 kgCO 2 e/t) and infectious waste (569 kgCO 2 e/t), we estimated the waste management cost and carbon footprint of waste disposal produced per RCR kit. RESULTS: The disposable systems of four commercial medical device companies had 783%, 570%, 1,051%, and 478%, respectively, greater mass and waste costs when compared with the reusable system. The cost of waste disposal for the reusable instrumentation system costs on average $0.14 less than the disposable instrumentation systems. The estimated contribution to the overall carbon footprint produced from the disposal of a RCR kit that uses reusable instrumentation was on average 0.37 kg CO2e less than the disposable instrumentation systems. CONCLUSION: According to our analysis, reusable instrumentation in four-anchor RCR leads to decreased waste and waste disposal costs and lower carbon emissions from waste disposal. Additional research should be done to assess the net benefit reusable systems may have on hospitals and the effect this may have on a long-term decrease in carbon footprint. LEVEL OF EVIDENCE: Level II.


Assuntos
Pegada de Carbono , Equipamentos Descartáveis , Reutilização de Equipamento , Humanos , Equipamentos Descartáveis/economia , Reutilização de Equipamento/economia , Eliminação de Resíduos de Serviços de Saúde , Lesões do Manguito Rotador/cirurgia , Lesões do Manguito Rotador/economia , Procedimentos Ortopédicos/instrumentação , Procedimentos Ortopédicos/economia , Âncoras de Sutura , Resíduos de Serviços de Saúde
3.
Surg Laparosc Endosc Percutan Tech ; 34(3): 321-329, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38767593

RESUMO

OBJECTIVE: Endoscopes are an essential tool in the diagnosis, screening, and treatment of gastrointestinal diseases. In 2019, the Food and Drug Administration issued a news release, recommending that duodenoscope manufacturers and health care facilities phase out fully reusable duodenoscopes with fixed endcaps in lieu of duodenoscopes that are either fully disposable or those that contain disposable endcaps. With this study, we systematically reviewed the published literature on single-use disposable gastrointestinal scopes to describe the current state of the literature and provide summary recommendations on the role of disposable gastrointestinal endoscopes. MATERIALS AND METHODS: For our inclusion criteria, we searched for studies that were published in the year 2015 and afterward. We performed a literature search in PubMed using the keywords, "disposable," "reusable," "choledochoscope," "colonoscope," "duodenoscope," "esophagoscope," "gastroscope," and "sigmoidoscope." After our review, we identified our final article set, including 13 articles relating to disposable scopes, published from 2015 to 2023. RESULTS: In this review, we show 13 articles discussing the infection rate, functionality, safety, and affordability of disposable gastrointestinal scopes in comparison to reusable gastrointestinal scopes. Of the 3 articles that discussed infection rates (by Forbes and colleagues, Ridtitid and colleagues, and Ofosu and colleagues), each demonstrated a decreased risk of infection in disposable gastrointestinal scopes. Functionality was another common theme among these articles. Six articles (by Muthusamy and colleagues, Bang and colleagues, Lisotti and colleagues, Ross and colleagues, Kang and colleagues, and Forbes and colleagues) demonstrated comparable functionality of disposable scopes to reusable scopes. The most reported functionality issue in disposable scopes was decreased camera resolution. Disposable scopes also showed comparable safety profiles compared with reusable scopes. Six articles (by Kalipershad and colleagues, Muthusamy and colleagues, Bang and colleagues, Lisotti and colleagues, Luo and colleagues, and Huynh and colleagues) showed comparable rates of AEs, whereas 1 article (by Ofosu and colleagues) demonstrated increased rates of AEs with disposable scopes. Lastly, a cost analysis was looked at in 3 of the articles. Two articles (by Larsen et al and Ross and colleagues) remarked that further research is needed to understand the cost of disposable scopes, whereas 1 article (by Kang and colleagues) showed a favorable cost analysis. CONCLUSIONS: After a review of the literature published since the 2015 Food and Drug Administration safety communication, disposable scopes have been shown to be effective in decreasing infection risks while maintaining similar safety profiles to conventional reusable scopes. However, more research is required to compare disposable and reusable scopes in terms of functionality and cost-effectiveness.


Assuntos
Equipamentos Descartáveis , Reutilização de Equipamento , Equipamentos Descartáveis/economia , Humanos , Reutilização de Equipamento/economia , Endoscópios Gastrointestinais , Desenho de Equipamento , Gastroenteropatias/diagnóstico , Endoscopia Gastrointestinal/instrumentação , Endoscopia Gastrointestinal/economia , Duodenoscópios/microbiologia
5.
Surg Endosc ; 38(6): 3361-3367, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38710887

RESUMO

INTRODUCTION: Disposable duodenoscopes and duodenoscopes with disposable endcaps are being used in clinical practice to reduce or eliminate the risk of transmitting infections. The study aim was to assess perceptions and experiences regarding the use of these duodenoscopes among advanced endoscopy fellows in a nationally representative sample. METHODS: A 17-item electronic survey was sent to 74 advanced endoscopy training programs. The survey was completed by 50 participants and their responses were included for analysis. RESULTS: Most participants were from academic training programs (82.7%) and identified as being in their 7th year of post graduate training (92%; PGY-7). Participants performed an average of 414 ERCPs. 29% reported difficulty with cannulation using disposable duodenoscopes versus 15.7% with duodenoscopes with disposable endcaps (vs. standard duodenoscope). 96% of trainees perceived disposable duodenoscopes as not cost effective and 92% stated they would not use this device during independent practice. 100% of trainees stated that they would use duodenoscopes with disposable endcaps during independent practice. For their most challenging cases, 90% of trainees preferred using standard reprocessable duodenoscopes while no trainee indicated they would prefer using a disposable duodenoscope in this scenario. 82% of participants stated that disposable duodenoscopes and disposable endcaps should be used exclusively or preferentially for high-risk patients citing cost, functionality, and concerns regarding environmental impact. DISCUSSION: Advanced endoscopy fellows perceive disposable duodenoscopes as impacting technical maneuverability. Concerns about functionality, cost effectiveness and environmental impact are barriers to adoption.


Assuntos
Equipamentos Descartáveis , Duodenoscópios , Equipamentos Descartáveis/economia , Humanos , Atitude do Pessoal de Saúde , Inquéritos e Questionários , Colangiopancreatografia Retrógrada Endoscópica , Internato e Residência , Estados Unidos
6.
Am J Obstet Gynecol ; 231(2): 273.e1-273.e7, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38761838

RESUMO

BACKGROUND: Single-use materials and equipment are regularly opened by the surgical team during procedures but left unused, potentially resulting in superfluous costs and excess environmental waste. OBJECTIVE: This study aimed to estimate the excess use of surgical supplies in minimally invasive benign gynecologic surgeries. STUDY DESIGN: This is a prospective observational study conducted at a university-affiliated single tertiary medical center. Designated study personnel were assigned to observe surgical procedures performed during July to September 2022. Surgical teams were observed while performing surgeries for benign indications. The teams were not informed of the purpose of the observation to avoid potential bias. Disposable materials and equipment opened during the procedure were documented. Excess supplies were defined as those opened but left unused before being discarded. Costs per item of the excess supplies were estimated on the basis of material and equipment costs provided by the hospital. RESULTS: A total of 99 surgeries were observed, including laparoscopic (32%), robotic (39%), hysteroscopic (14%), vaginal (11%), and laparotomy procedures (3%). Excess use of surgical supplies was documented in all but one procedure. The total cost across all surgeries reached $6357. The contained tissue extraction bag was the most expensive item not used (Applied Medical, Rancho Santa Margarita, CA; $390 per unit) in 4 procedures, contributing 25.54% to the total cost. Raytec was the most common surgical waste, with a total of n=583 opened but unused (average n=5.95 per surgery). A significant difference was found in the rate of excess supplies across the surgical approaches, with robotic surgery contributing 52.19% of the total cost (P=.01). CONCLUSION: Excess use of disposable materials and equipment is common in minimally invasive benign gynecologic surgeries and contributes to superfluous costs and excess environmental waste. It is predominantly attributed to the opening of inexpensive materials that are left unused during the procedure. Increased awareness of costs and generated waste may reduce excess use of surgical supplies and should be further explored in future research.


Assuntos
Procedimentos Cirúrgicos em Ginecologia , Procedimentos Cirúrgicos Robóticos , Humanos , Feminino , Procedimentos Cirúrgicos em Ginecologia/instrumentação , Procedimentos Cirúrgicos em Ginecologia/economia , Procedimentos Cirúrgicos em Ginecologia/estatística & dados numéricos , Estudos Prospectivos , Procedimentos Cirúrgicos Robóticos/economia , Procedimentos Cirúrgicos Robóticos/estatística & dados numéricos , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/economia , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Laparoscopia/economia , Laparoscopia/estatística & dados numéricos , Laparoscopia/instrumentação , Histeroscopia/economia , Histeroscopia/estatística & dados numéricos , Equipamentos Descartáveis/economia , Equipamentos Descartáveis/provisão & distribuição , Laparotomia/economia , Adulto , Pessoa de Meia-Idade
8.
Clin Transplant ; 38(5): e15321, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38716774

RESUMO

INTRODUCTION & OBJECTIVES: To evaluate ureteral stent removal (SR) using a grasper-integrated disposable flexible cystoscope (giFC-Isiris ®, Coloplast ®) after kidney transplantation (KT), with a focus on feasibility, safety, patient experience, and costs. MATERIAL AND METHODS: All consecutive KT undergoing SR through giFC were prospectively enrolled from January 2020 to June 2023. Patient characteristics, KT and SR details, urine culture results, antimicrobial prescriptions, and the incidence of urinary tract infections (UTI) within 1 month were recorded. A micro-cost analysis was conducted, making a comparison with the costs of SR with a reusable FC and grasper. RESULTS: A total of 136 KT patients were enrolled, including both single and double KT, with 148 stents removed in total. The median indwelling time was 34 days [26, 47]. SR was successfully performed in all cases. The median preparation and procedure times were 4 min [3,5]. and 45 s[30, 60], respectively. The median Visual Analog Scale (VAS) score was 3 [1, 5], and 98.2% of patients expressed willingness to undergo the procedure again. Only one episode of UTI involving the graft (0.7%) was recorded. Overall, the estimated cost per SR procedure with Isiris ® and the reusable FC was 289.2€ and 151,4€, respectively. CONCLUSIONS: This prospective series evaluated the use of Isiris ® for SR in a cohort of KT patients, demonstrating feasibility and high tolerance. The UTI incidence was 0.7% within 1 month. Based on the micro-cost analysis, estimated cost per procedure favored the reusable FC.


Assuntos
Cistoscopia , Remoção de Dispositivo , Equipamentos Descartáveis , Estudos de Viabilidade , Transplante de Rim , Stents , Humanos , Feminino , Masculino , Transplante de Rim/economia , Pessoa de Meia-Idade , Stents/economia , Remoção de Dispositivo/economia , Estudos Prospectivos , Seguimentos , Equipamentos Descartáveis/economia , Cistoscopia/economia , Cistoscopia/métodos , Cistoscopia/instrumentação , Complicações Pós-Operatórias , Centros de Atenção Terciária , Prognóstico , Adulto , Ureter/cirurgia , Infecções Urinárias/etiologia , Infecções Urinárias/economia , Custos e Análise de Custo
10.
Am Surg ; 90(8): 2127-2129, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38561960

RESUMO

The operating room has been identified as one of the primary contributors to waste and energy expenditure in the health care system. The primary objective of our study was to evaluate the efficacy of single-use device reprocessing and report the cost savings, waste diversion, and reduction in carbon emissions. Data was collected from January 2021 to April 2023. Medline collected the data for analysis and converted it from an Excel file format to SPSS (Version 27) for analysis. Descriptive frequencies were used for data analysis. We found a mean monthly cost savings of $16,051.68 and a mean 700.68 pounds of waste a month diverted, resulting in an estimated yearly saving of $2354.29 in disposal costs and a reduction of 1112.65 CO2e emissions per month. This program has made significant contributions to cost savings and environmental efforts.


Assuntos
Redução de Custos , Reutilização de Equipamento , Salas Cirúrgicas , Centros de Atenção Terciária , Centros de Atenção Terciária/economia , Reutilização de Equipamento/economia , Humanos , Salas Cirúrgicas/economia , Equipamentos Descartáveis/economia , Centro Cirúrgico Hospitalar/economia
11.
Urology ; 188: 70-76, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38499187

RESUMO

OBJECTIVE: To conduct a comparative cost analysis between single-use and reusable cystoscopes from a national healthcare system perspective and assess the environmental footprint. METHODS: Single-center micro-cost analysis of reusable vs single-use cystoscopes used institutional data. The cost breakdown included capital, reprocessing, repair, procedure, and environmental impact expenses. Data collection occurred in 2022, utilizing registered data, observations, and expert opinions. Depreciation was applied over 5 years for reusable cystoscopes and 8 years for the automated endoscope reprocessor. Deterministic sensitivity analyses gauged result robustness to input variations. Lastly, an assessment of the environmental footprint, focusing on water consumption and waste generation, was conducted. RESULTS: Per-procedure cost associated with reusable cystoscopes was €332.46 vs €220.19 associated with single-use, resulting in savings of €112.27. When projecting these costs per procedure with the number of procedures performed in 2022 (1186), comparing the costs of procedures performed in 1 year with reusable endoscopes (€394,295.86) to the costs of the exact number of procedures performed with disposable endoscopes (€261,149.37), a saving of €133,146.49 could be achieved. Additionally, after continuous use of single-use endoscopes, procedures were scheduled every 20 minutes instead of every 30 minutes. This adjustment allowed for 15 daily procedures instead of 10 while maintaining the same shift. This suggests potential advantages in terms of improved organizational impact and reduced waiting lists. Ultimately, the decreased environmental impact favored the adoption of single-use cystoscopes. CONCLUSION: Our study presents an opportunity for organizational development in response to the evolving external environment, considering user needs, market dynamics, and competition with other facilities.


Assuntos
Custos e Análise de Custo , Cistoscópios , Equipamentos Descartáveis , Reutilização de Equipamento , Reutilização de Equipamento/economia , Equipamentos Descartáveis/economia , Cistoscópios/economia , Humanos , Meio Ambiente
12.
BJU Int ; 133(6): 638-645, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38438065

RESUMO

OBJECTIVE: To explore the data comparing single- vs multi-use catheters for clean intermittent catheterisation (CIC), consider if the widespread use of single-use catheters is warranted given the cost and environmental impact, and put forth ideas for future consideration. METHODS: A primary literature review was performed in PubMed over the past 50 years. Studies that performed comparative analysis of single- and multi-use catheters were included in our review. All studies that reported on primary data were narratively summarised. RESULTS: A total of 11 studies were identified that reported on primary data comparing single- and multi-use catheters. There was no appreciable evidence suggesting reusable multi-use catheters were inferior to single-use catheters from an infection or usability standpoint. In addition, the environmental and monetary burden of single-use catheters is significant. CONCLUSIONS: The intermittent catheter landscape in the USA has a complex past: defined by policy, shaped by industry, yet characterised by a paucity of data demonstrating superiority of single-use over multi-use catheters. We believe that the aversion to reusable catheters by many patients and healthcare professionals is unwarranted, especially given the cost and environmental impact. Moving forward, better comparative data and more sustainable practices are needed.


Assuntos
Reutilização de Equipamento , Humanos , Reutilização de Equipamento/economia , Equipamentos Descartáveis/economia , Meio Ambiente , Cateteres Urinários , Cateterismo Uretral Intermitente/instrumentação
13.
Gastrointest Endosc ; 100(2): 312-316, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38462055

RESUMO

BACKGROUND AND AIMS: Duodenoscopes with single-use end caps were introduced to minimize infection risk, but they are unstudied in pediatrics. METHODS: We collected clinical data and endoscopists' evaluations of duodenoscopes with single-use end caps versus reusable duodenoscopes over 18 months. RESULTS: A total of 106 ERCPs were performed for patients aged 1 to 18 (mean, 14.2) years. Forty-six involved single-use end caps, with 9 requiring crossover to reusable duodenoscopes. ERCPs involving single-use end caps resulted in more instances of mucosal trauma (10 vs 0; P < .05) and post-ERCP pancreatitis (4 vs 1; P < .05) and accounted for 8 of 9 ERCPs requiring advanced cannulation techniques. No post-ERCP infections occurred. Reported challenges included single-use end cap stiffness and difficulty with their alignment for cannulation. CONCLUSIONS: We report difficulty with advancement, greater reliance on advanced cannulation techniques, and higher rates of post-ERCP pancreatitis when using duodenoscopes with single-use end caps in pediatric ERCP. This area warrants further study.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Duodenoscópios , Humanos , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Duodenoscópios/microbiologia , Criança , Adolescente , Pré-Escolar , Lactente , Feminino , Masculino , Pancreatite/prevenção & controle , Pancreatite/etiologia , Reutilização de Equipamento/economia , Desenho de Equipamento , Equipamentos Descartáveis/economia , Estudos Retrospectivos , Cateterismo
14.
Anesth Analg ; 139(1): 220-225, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38195082

RESUMO

BACKGROUND: Operating room (OR) expenditures and waste generation are a priority, with several professional societies recommending the use of reprocessed or reusable equipment where feasible. The aim of this analysis was to compare single-use pulse oximetry sensor stickers ("single-use stickers") versus reusable pulse oximetry sensor clips ("reusable clips") in terms of annual cost savings and waste generation across all ORs nationally. METHODS: This study did not involve patient data or research on human subjects. As such, it did not meet the requirements for institutional review board approval. An economic model was used to compare the relative costs and waste generation from using single-use stickers versus reusable clips. This model took into account: (1) the relative prices of single-use stickers and reusable clips, (2) the number of surgeries and ORs nationwide, (3) the workload burden of cleaning the reusable clips, and (4) the costs of capital for single-use stickers and reusable clips. In addition, we also estimated differences in waste production based on the raw weight plus unit packaging of single-use stickers and reusable clips that would be disposed of over the course of the year, without any recycling interventions. Estimated savings were rounded to the nearest $0.1 million. RESULTS: The national net annual savings of transitioning from single-use stickers to reusable clips in all ORs ranged from $510.5 million (conservative state) to $519.3 million (favorable state). Variability in savings estimates is driven by scenario planning for replacement rate of reusable clips, workload burden of cleaning (ranging from an additional expense of $618k versus a cost savings of $309k), and cost of capital-interest gained on investment of capital that is freed up by the monetary savings of a transition to reusable clips contributes between $541k (low-interest rates of 2.85%) and $1.3 million (high-interest rates of 7.08%). The annual waste that could be diverted from landfill by transitioning to reusable clips was found to be between 587 tons (conservative state) up to 589 tons (favorable state). If institutions need to purchase new vendor monitors or cables to make the transition, that may increase the 1-time capital disbursement. CONCLUSIONS: Using reusable clips versus single-use stickers across all ORs nationally would result in appreciable annual cost savings and waste generation reduction impact. As both single-use stickers and reusable clips are equally accurate and reliable, this cost and waste savings could be instituted without a compromise in clinical care.


Assuntos
Redução de Custos , Equipamentos Descartáveis , Reutilização de Equipamento , Salas Cirúrgicas , Oximetria , Salas Cirúrgicas/economia , Oximetria/economia , Oximetria/instrumentação , Reutilização de Equipamento/economia , Humanos , Estados Unidos , Equipamentos Descartáveis/economia , Modelos Econômicos , Custos Hospitalares
15.
J Visc Surg ; 161(2S): 25-31, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38272757

RESUMO

INTRODUCTION: The objective of this systematic review of the literature is to compare a selection of currently utilized disposable and reusable laparoscopic medical devices in terms of safety (1st criteria), cost and carbon footprint. MATERIAL AND METHODS: A search was carried out on electronic databases for articles published up until 6 May 2022. The eligible works were prospective (randomized or not) or retrospective clinical or medical-economic comparative studies having compared disposable scissors, trocars, and mechanical endoscopic staplers to the same instruments in reusable. Two different independent examiners extracted the relevant data. RESULTS: Among the 2882 articles found, 156 abstracts were retained for examination. After comprehensive analysis concerning the safety and effectiveness of the instruments, we included four articles. A study on trocars highlighted increased vascular complications with disposable instruments, and another study found more perioperative incidents with a hybrid stapler as opposed to a disposable stapler. As regards cost analysis, we included 11 studies, all of which showed significantly higher costs with disposable instruments. The results of the one study on carbon footprints showed that hybrid instruments leave four times less of a carbon footprint than disposable instruments. CONCLUSION: The literature on the theme remains extremely limited. Our review demonstrated that from a medical and economic standpoint, reusable medical instruments, particularly trocars, presented appreciable advantages. While there exist few data on the ecological impact, those that do exist are unmistakably favorable to reusable instruments.


Assuntos
Pegada de Carbono , Equipamentos Descartáveis , Reutilização de Equipamento , Laparoscopia , Equipamentos Descartáveis/economia , Humanos , Reutilização de Equipamento/economia , Laparoscopia/economia , Laparoscopia/instrumentação
16.
J Clin Gastroenterol ; 56(7): 597-600, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34267104

RESUMO

GOAL: The goal of this study was to determine the financial impact of adopting the US Multi-Society Task Force (USMSTF) polypectomy guidelines on physician reimbursement and disposable equipment costs for gastroenterologists in the academic medical center and community practice settings. BACKGROUND: In 2020, USMSTF guidelines on polypectomy were introduced with a strong recommendation for cold snare rather than cold forceps technique for removing diminutive and small polyps. Polypectomy with snare technique reimburses physicians at a higher rate compared with cold forceps and also requires different disposable equipment. The financial implications of adopting these guidelines is unknown. MATERIALS AND METHODS: Patients that underwent screening colonoscopy where polypectomy was performed at an academic medical center (Loma Linda University Medical Center) and community practice medical center (Ascension Providence Hospital) between July 2018 and July 2019 were identified. The polypectomy technique performed during each procedure was determined (forceps alone, snare alone, forceps plus snare) along with the number and size of polyps as well as disposable equipment. Actual and projected provider reimbursement and disposable equipment costs were determined based on applying the new polypectomy guidelines. RESULTS: A total of 1167 patients underwent colonoscopy with polypectomy. Adhering to new guidelines would increase estimated physician reimbursement by 5.6% and 12.5% at academic and community practice sites, respectively. The mean increase in physician reimbursement per procedure was significantly higher at community practice compared with the academic setting ($29.50 vs. $14.13, P <0.00001). The mean increase in disposable equipment cost per procedure was significantly higher at the community practice setting ($6.11 vs. $1.97, P <0.00001). CONCLUSION: Adopting new polypectomy guidelines will increase physician reimbursement and equipment costs when colonoscopy with polypectomy is performed.


Assuntos
Pólipos do Colo/cirurgia , Neoplasias Colorretais/cirurgia , Fidelidade a Diretrizes/economia , Centros Médicos Acadêmicos/economia , Pólipos do Colo/economia , Colonoscopia/economia , Colonoscopia/métodos , Neoplasias Colorretais/economia , Centros Comunitários de Saúde/economia , Equipamentos Descartáveis/classificação , Equipamentos Descartáveis/economia , Humanos , Instrumentos Cirúrgicos/economia
17.
Urol Clin North Am ; 49(1): 153-159, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34776048

RESUMO

Ureteroscopy is the most common surgical modality for stone treatment. Reusable flexible ureteroscopes are delicate instruments that require expensive maintenance and repairs. Multiple single use ureteroscopes have been developed recently to combat the expensive and time-intensive sterilization and repair of ureteroscopes. Although multiple studies have looked at different aspects of reusable and single use ureteroscopes, there is significant heterogeneity in performance measures and cost between the 2 categories, and neither has a clear advantage. Both can be used successfully, and individual and institution level factors should be considered when deciding which ureteroscope to use.


Assuntos
Equipamentos Descartáveis , Meio Ambiente , Contaminação de Equipamentos , Ureteroscópios , Equipamentos Descartáveis/economia , Equipamentos Descartáveis/normas , Humanos , Manutenção/economia , Ureteroscópios/economia , Ureteroscópios/normas , Urolitíase/cirurgia
18.
World J Urol ; 39(11): 4275-4281, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34019137

RESUMO

PURPOSE: To evaluate the total cost of outpatient flexible cystoscopy associated with reusable device purchase, maintenance, and reprocessing, and to assess potential cost benefits of single-use flexible cystoscopes. METHODS: Cost data regarding the purchasing, maintaining, and reprocessing of reusable flexible cystoscopes were collected using a micro-costing approach at a high-volume outpatient urology clinic. We estimated the costs to facilities with a range of annual procedure volumes (1000-3000) performed with a fleet of cystoscopes ranging from 10 to 25. We also compared the total cost per double-J ureteral stent removal procedure performed using single-use flexible cystoscopes versus reusable devices. RESULTS: The cost associated with reusable flexible cystoscopes ranged from $105 to $224 per procedure depending on the annual procedure volume and cystoscopes available. As a practice became more efficient by increasing the ratio of procedures performed to cystoscopes in the fleet, the proportion of the total cost due to cystoscope reprocessing increased from 22 to 46%. For ureteral stent removal procedures, the total cost per procedure using reusable cystoscopes (range $165-$1469) was higher than that using single-use devices ($244-$420), unless the annual procedure volume was sufficiently high relative to the number of reusable cystoscopes in the fleet (≥ 350 for a practice with ten reusable cystoscopes, ≥ 700 for one with 20 devices). CONCLUSION: The cost of reprocessing reusable cystoscopes represents a large fraction of the total cost per procedure, especially for high-volume facilities. It may be economical to adopt single-use cystoscopes specifically for stent removal procedures, especially for lower-volume facilities.


Assuntos
Custos e Análise de Custo , Cistoscópios/economia , Cistoscopia/economia , Cistoscopia/instrumentação , Equipamentos Descartáveis/economia , Procedimentos Cirúrgicos Ambulatórios , Desenho de Equipamento , Humanos
19.
J Vasc Interv Radiol ; 32(5): 672-676, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33781687

RESUMO

PURPOSE: To analyze the impact of physician-specific equipment preference on cost variation for procedures typically performed by interventional radiologists at a tertiary care academic hospital. MATERIALS AND METHODS: From October 2017 to October 2019, data on all expendable items used by 9 interventional radiologists for 11 common interventional radiology procedure categories were compiled from the hospital analytics system. This search yielded a final dataset of 44,654 items used in 2,121 procedures of 11 different categories. The mean cost per case for each physician as well as the mean, standard deviation, and coefficient of variation (CV) of the mean cost per case across physicians were calculated. The proportion of spending by item type was compared across physicians for 2 high-variation, high-volume procedures. The relationship between the mean cost per case and case volume was examined using linear regression. RESULTS: There was a high variability within each procedure, with the highest and the lowest CV for radioembolization administration (56.6%) and transjugular liver biopsy (4.9%), respectively. Variation in transarterial chemoembolization cost was mainly driven by microcatheters/microwires, while for nephrostomy, the main drivers were catheters/wires and access sets. Mean spending by physician was not significantly correlated with case volume (P =.584). CONCLUSIONS: Physicians vary in their item selection even for standard procedures. While the financial impact of these differences vary across procedures, these findings suggest that standardization may offer an opportunity for cost savings.


Assuntos
Equipamentos Descartáveis/economia , Custos de Cuidados de Saúde , Disparidades em Assistência à Saúde/economia , Papel do Médico , Padrões de Prática Médica/economia , Radiografia Intervencionista/economia , Radiografia Intervencionista/instrumentação , Radiologistas/economia , Atitude do Pessoal de Saúde , Comportamento de Escolha , Tomada de Decisão Clínica , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Estudos Retrospectivos
20.
J Orthop Surg Res ; 16(1): 188, 2021 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-33722256

RESUMO

BACKGROUND: Total knee arthroplasty (TKA) is most frequently planned using conventional two-dimensional weight-bearing lower limb radiographs and is performed with conventional femoral and tibial cutting guides. Questions have been raised about the accuracy of conventional TKA instrumentation and planning for an anatomically standard or complex joint. Use of computed tomography (CT)-based three-dimensional (3D) templating and patient-specific cutting guides printed in 3D has shown improved postoperative lower limb alignment parameters. This case-control study compared costs and operative times of using CT-based, patient-specific, single-use instruments versus conventional metal instruments for TKA. METHODS: In this case-control, retrospective chart review, all TKAs were performed by one senior surgeon, using the F.I.R.S.T. posterior-stabilised knee prosthesis (Symbios, CH), with a similar protocol and identical operating room setup. Group A included 51 TKAs performed with patient-specific cutting guides and conventional metal instruments. Group B included 49 TKAs performed with patient-specific cutting guides and patient-specific, single-use instrumentation. Operation duration, number of instrumentation trays and sterilisation costs were evaluated. RESULTS: The groups were similar for age, body mass index, hip-knee-ankle angle and operation duration. The mean number of instrumentation trays was 8.0 ± 0.8 for group A (controls) and 5.1 ± 0.9 for group B (p<0.001). The mean sterilisation costs were 380 ± 47 Swiss Francs (CHF) for group A and 243 ± 55 CHF for group B (p<0.001), for a mean cost reduction of 130.50 CHF per intervention in group B. The time interval between two consecutive surgeries was 24 min for group A and 18 min for group B. There were no adverse events or complications, instrument-related or otherwise. CONCLUSION: Compared to conventional instrumentation, use of patient-specific, single-use instruments for TKA reduced the number of instrumentation trays by more than one-third and saved 36% in sterilisation costs. If fabrication costs of single-use instruments are included by the company, the total cost is significantly diminished. There was no operative time advantage for single-use instrumentation.


Assuntos
Artroplastia do Joelho/economia , Artroplastia do Joelho/instrumentação , Custos e Análise de Custo , Equipamentos Descartáveis , Esterilização/economia , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Equipamentos Descartáveis/economia , Feminino , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Retrospectivos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...