Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.031
Filtrar
2.
Arch Iran Med ; 27(9): 479-485, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39465522

RESUMO

BACKGROUND: Iran Premature Coronary Artery Disease (IPAD) is one of the first and largest studies of its kind in Asia that investigates different aspects of premature coronary artery disease (PCAD) in different ethnic groups in multiple cities. In this paper, we aim to describe the IPAD biobank establishment and present some preliminary results of the IPAD study. METHODS: This case-control study was conducted on patients with documented angiography from different ethnicities in more than ten cities of Iran (males aged 60 years and below and females aged 70 years and below). Patients with coronary artery stenosis of more than 75% in at least one vessel (or left-main stenosis of more than 50%) were defined as the case group and patients with normal coronary angiography were considered as the control group. In addition to completing questionnaires and performing physical measurements, samples of serum, buffy coat, plasma, whole blood, saliva, urine, and feces were stored in the freezer at -80 °C. RESULTS: The mean age of patients was 51.1±8.2, of which 43% were women. There were 1221 people in the control group and 1702 in the case group. Our enrollment is completed and data entry and transferring biosamples from different cities is still ongoing. About 30000 biosamples of different ethnicities are saved in the IPAD biobank. CONCLUSION: This study aims to develop a high-quality biobank and facilitate research on different aspects of PCAD, especially gene-environment interaction regarding ethnicity.


Assuntos
Bancos de Espécimes Biológicos , Doença da Artéria Coronariana , Humanos , Feminino , Estudos de Casos e Controles , Irã (Geográfico) , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Angiografia Coronária , Computadores de Mão , Estenose Coronária
3.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(5): 1026-1034, 2024 Oct 25.
Artigo em Chinês | MEDLINE | ID: mdl-39462672

RESUMO

The hemodynamic parameters in arteries are difficult to measure non-invasively, and the analysis and prediction of hemodynamic parameters based on computational fluid dynamics (CFD) has become one of the important research hotspots in biomechanics. This article establishes 15 idealized left coronary artery bifurcation models with concomitant stenosis and aneurysm lesions, and uses CFD method to numerically simulate them, exploring the effects of left anterior descending branch (LAD) stenosis rate and curvature radius on the hemodynamics inside the aneurysm. This study compared models with different stenosis rates and curvature radii and found that as the stenosis rate increased, the oscillatory shear index (OSI) and relative residence time (RRT) showed a trend of increase; In addition, the decrease in curvature radius led to an increase in the degree of vascular curvature and an increased risk of vascular aneurysm rupture. Among them, when the stenosis rate was less than 60%, the impact of stenosis rate on aneurysm rupture was greater, and when the stenosis rate was greater than 60%, the impact of curvature radius was more significant. Based on the research results of this article, it can be concluded that by comprehensively considering the effects of stenosis rate and curvature radius on hemodynamic parameters, the risk of aneurysm rupture can be analyzed and predicted. This article uses CFD methods to deeply explore the effects of stenosis rate and curvature radius on the hemodynamics of aneurysms, providing new theoretical basis and prediction methods for the assessment of aneurysm rupture risk, which has important academic value and practical guidance significance.


Assuntos
Simulação por Computador , Aneurisma Coronário , Hemodinâmica , Hidrodinâmica , Modelos Cardiovasculares , Humanos , Aneurisma Coronário/fisiopatologia , Aneurisma Coronário/etiologia , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia
4.
EuroIntervention ; 20(20): e1288-e1297, 2024 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-39432253

RESUMO

BACKGROUND: Coronary computed tomography angiography (CCTA)-derived Murray law-based quantitative flow ratio (CT-µFR) is a novel non-invasive method for fast computation of fractional flow reserve (FFR) from CCTA images, yet its diagnostic performance remains to be prospectively validated. AIMS: We aimed to evaluate the diagnostic performance of onsite CT-µFR in patients with coronary artery disease. METHODS: This prospective, single-centre trial enrolled patients with ≥1 lesion with 30-90% diameter stenosis on CCTA and planned invasive coronary angiography (ICA) within 30 days. CT-µFR, ICA-derived µFR and FFR were evaluated separately in a blinded fashion. The primary endpoint was the diagnostic accuracy of CT-µFR in identifying patients with haemodynamically significant coronary stenosis defined by the invasive standard: FFR ≤0.80, or µFR ≤0.80 when FFR was not available. RESULTS: Between December 2020 and August 2023, 260 patients were consecutively enrolled. Paired comparison between CT-µFR and the invasive standard was obtained in 706 vessels from 260 patients. The patient-level accuracy of CT-µFR was 89.6% (95% confidence interval [CI]: 85.9-93.4%), which was significantly higher than the prespecified target of 72.0% (p<0.001). Sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios for CT-µFR were 93.1%, 86.1%, 87.1%, 92.5%, 6.7, and 0.1, respectively. Out of the 231 vessels investigated by FFR, the accuracy of CT-µFR in vessels without extensive calcification was non-inferior to that of µFR (90.6% vs 88.9%; difference=1.8% [95% CI: -2.8 to 5.5%]; p for non-inferiority<0.001). CONCLUSIONS: The study met its prespecified primary endpoint of the diagnostic accuracy of CT-µFR in identifying patients with haemodynamically significant coronary stenosis. CT-µFR was non-inferior to ICA-derived µFR in vessels without extensive calcification. (ClinicalTrials.gov: NCT04665817).


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Feminino , Masculino , Angiografia por Tomografia Computadorizada/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Pessoa de Meia-Idade , Idoso , Angiografia Coronária/métodos , Estudos Prospectivos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
5.
EuroIntervention ; 20(19): e1237-e1247, 2024 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-39374092

RESUMO

BACKGROUND: In order to identify coronary lesions that cause myocardial ischaemia and require revascularisation, fractional flow reserve (FFR) is widely recommended. Recently, a method of estimating the FFR using morphological features measured by an imaging device was developed. However, all the previously developed methods are conducted offline, and such analysis takes approximately 10 minutes. AIMS: The aim of this present study was to develop an online measurement of the FFR using an intravascular ultrasound (IVUS) quantitative method (IQ-FFR). METHODS: This prospective, single-centre study included coronary lesions that met the following criteria: (1) presence of at least one stenosis (25-99%); (2) both IVUS and FFR measurement performed just before and after stent implantation, with the wire-derived FFR measured with a standard method; and (3) acquisition of clear images throughout the entire coronary branch. RESULTS: We developed an IVUS analysis system that automatically measures the cross-sectional area every 0.5 mm, and we calculated the IQ-FFR. In the prediction study, we calculated the IQ-FFR on the assumption that one stent of arbitrary length and diameter was implanted. After stent implantation, the wire-derived FFR was measured and compared with the calculated IQ-FFR. We compared 270 coronary lesions with stenosis rates of 32-99%. IQ-FFR measurements were strongly correlated with the wire-derived FFR (r=0.896). In the prediction study, the clinical accuracy of predicting whether the FFR would be greater or less than 0.80 after stent implantation was 87.5%. CONCLUSIONS: The IQ-FFR is a promising method to identify coronary lesions requiring revascularisation and to predict the FFR after stent implantation.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Ultrassonografia de Intervenção , Humanos , Ultrassonografia de Intervenção/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Estenose Coronária/terapia , Angiografia Coronária/métodos , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/instrumentação , Stents , Valor Preditivo dos Testes , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia
6.
BMC Cardiovasc Disord ; 24(1): 561, 2024 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-39407107

RESUMO

OBJECTIVE: To explore the diagnostic value of intermittent changes in the nocturnal ST segment trend graph in a dynamic electrocardiogram (ECG) for coronary heart disease (CHD). METHODS: A total of 205 patients who underwent coronary angiography were included in this retrospective study. The study sample was determined through a power analysis aimed at achieving power of 80% with a significance level of 0.05. The participants were divided into the CHD (n = 101) and the non-CHD (n = 104) group, based on the degree of coronary artery diameter stenosis. The morphological changes in the ST segment trend graph were observed and divided into two categories: 'wall-shaped' and 'peak-shaped' changes. RESULTS: Among the 205 patients, 94 had nocturnal ST segment dynamic changes and 111 did not. The detection rate of CHD without nocturnal ST segment dynamic changes was 21.59%, significantly lower than the detection rate of 93.18% in those with nocturnal ST segment changes, reflecting a statistically significant difference (P < 0.05). The positive rate of ST segment in patients with single-vessel disease (71.88%) was lower than in patients with multi-vessel disease (78.57%), and both differences were statistically significant (P < 0.05). The duration of ST segment trend graph changes in 94 cases in the CHD group with intermittent changes in the nocturnal ST segment trend graph was higher than in the non-CHD group, but no significant difference was observed (P > 0.05). The detection rate of CHD in the peak-shaped dynamic change group of the nocturnal ST segment trend graph was significantly higher (76/82) than in the wall-shaped (6/82) dynamic change group (P < 0.05). CONCLUSION: Peak-shaped changes in the nocturnal ST segment trend graph indicate coronary artery lesions. Nocturnal ST segment changes observed through dynamic ECG monitoring can serve as a valuable non-invasive predictor for CHD, providing a feasible method for early diagnosis and intervention in clinical practice.


Assuntos
Ritmo Circadiano , Angiografia Coronária , Eletrocardiografia , Frequência Cardíaca , Valor Preditivo dos Testes , Humanos , Masculino , Estudos Retrospectivos , Feminino , Pessoa de Meia-Idade , Idoso , Fatores de Tempo , Doença das Coronárias/fisiopatologia , Doença das Coronárias/diagnóstico , Doença das Coronárias/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Estenose Coronária/diagnóstico , Estenose Coronária/diagnóstico por imagem , Reprodutibilidade dos Testes , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico , Potenciais de Ação
7.
Catheter Cardiovasc Interv ; 104(4): 676-687, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39219464

RESUMO

BACKGROUND: Modified balloon (MB) treatment in severely calcified coronary artery lesions is an established technique. However, some lesions require Rotablation (RA) as bailout strategy. AIMS: This study aimed to assess predictors of switch from MB to RA and its impact on procedural and midterm outcomes. METHODS: Four hundred and eighty-three consecutive patients were included undergoing MB treatment (n = 204) with a scoring or cutting balloon, or upfront RA treatment (n = 279) serving as control cohort. Strategy switch from MB to RA was performed in 19 of 204 patients. Procedural success was defined as successful stent implantation and TIMI III flow. RESULTS: In the MB cohort, median age was 72 [63-78] years, 75.5% were male and 42.1% had acute coronary syndrome. Procedure success was achieved in 89.4% of the switch group versus 98.4% of the MB only group (p < 0.001) and in 96.4% of the RA cohort. In the switch group, periprocedural complications (31.6% vs. 8.1% vs. 11.8%, p = 0.007), radiation dose (149 [126-252] vs. 59 [30-97] vs. 102 [59-156] Gcm2; p < 0.001) and contrast volume (250 [190-250] vs. 190 [150-250] vs. 195 [190--250] mL; p < 0.001) were significantly higher. Diabetes (OR 3.8, 95% CI 1.1-13.9, p = 0.042), chronic kidney disease stage 4 or 5 (OR 19.0, 95% CI 3.3-108.6, p < 0.001) and pronounced calcification resulting in higher angiographic diameter stenosis (OR 1.13, 95% CI 1.1-1.2, p = 0.001) independently predicted strategy switch. Midterm results were not affected by strategy switch regarding 1-year target lesion revascularization rates (86% vs. 89% vs. 89%; log-rank p = 0.95). CONCLUSION: Primary RA strategy might be considered in patients with severely calcified coronary artery lesions with high angiographic diameter stenosis, diabetes or impaired renal function due to increased periprocedural complication rates, radiation dose, and contrast volume following strategy switch.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Estenose Coronária , Índice de Gravidade de Doença , Calcificação Vascular , Humanos , Masculino , Feminino , Idoso , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Pessoa de Meia-Idade , Resultado do Tratamento , Fatores de Risco , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Fatores de Tempo , Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/efeitos adversos , Estudos Retrospectivos , Diabetes Mellitus , Medição de Risco , Nefropatias/terapia , Stents , Angiografia Coronária
8.
J Cardiothorac Surg ; 19(1): 543, 2024 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-39307907

RESUMO

BACKGROUND: The purpose of this study was to explore the expression of miR-665 in acute myocardial infarction (AMI) and evaluate its significance in the diagnosis and prognosis of AMI. METHODS: 100 patients with AMI were selected as the study group and 80 healthy subjects were chosen as the control group. The levels of miR-665 were detected by reverse transcription quantitative polymerase chain reaction (RT-qPCR) in the two groups. The diagnostic value of miR-665 expression level in AMI was analyzed by the receiver operator characteristic (ROC) curve. Kaplan-Meier curve and Cox regression were used to evaluate the predictive value of miR-665 for major adverse cardiovascular events (MACEs) in patients with AMI within 30 days after percutaneous coronary intervention (PCI). RESULTS: The serum miR-665 level of the study group was significantly lower than that of the control group. The level of miR-665 was significantly correlated with clinical indicators of patients with AMI. ROC curve showed that miR-665 has a high diagnostic value for AMI. Survival analysis showed that Gensini score and miR-665 were independent risk factors for the occurrence of MACEs within 30 days after PCI in patients with AMI. CONCLUSIONS: Abnormal decrease of serum miR-665 expression level in patients with AMI may increase the risk of MACEs occurrence after PCI.


Assuntos
Estenose Coronária , MicroRNAs , Infarto do Miocárdio , Humanos , Masculino , Feminino , MicroRNAs/sangue , Infarto do Miocárdio/sangue , Infarto do Miocárdio/genética , Pessoa de Meia-Idade , Estenose Coronária/sangue , Estenose Coronária/cirurgia , Estenose Coronária/genética , Intervenção Coronária Percutânea , Idoso , Prognóstico , Curva ROC , Biomarcadores/sangue
9.
Int J Cardiovasc Imaging ; 40(10): 2213-2220, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39259436

RESUMO

Coronary CT angiography (CTA) derived fractional flow reserve (FFRCT) is recommended for physiological assessment in intermediate coronary stenosis for guiding referral to invasive coronary angiography (ICA). In this study, we report real-world data on the feasibility of implementing a CTA/FFRCT test algorithm as a gatekeeper to ICA at referral hospitals. Retrospective all-comer study of patients with new onset stable symptoms and suspected coronary stenosis (30-89%) by CTA. Evaluation of CTA datasets, interpretation of FFRCT analysis, and decisions on downstream testing were performed by skilled CT-cardiologists. CTA was performed in 3974 patients, of whom 381 (10%) were referred directly to ICA, whereas 463 (12%) to non-invasive functional testing: FFRCT 375 (81%) and perfusion imaging 88 (19%). FFRCT analysis was rejected in 8 (2%) due to inadequate CTA image quality. Number of patients deferred from ICA after FFRCT was 267 (71%), while 100 (27%) were referred to ICA. Obstructive coronary artery disease (CAD) was confirmed in 62 (62%) patients and revascularization performed in 53 (53%). Revascularization rates, n (%), were higher in patients undergoing FFRCT-guided versus CTA-guided referral to ICA: 30-69% stenosis, 28 (44%) versus 8 (21%); 70-89% stenosis, 39 (69%) versus 25 (46%), respectively, both p < 0.05. Implementation of FFRCT at referral hospitals was feasible, reduced the number of invasive procedures, and increased the revascularization rate.


Assuntos
Angina Estável , Tomada de Decisão Clínica , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária , Estudos de Viabilidade , Reserva Fracionada de Fluxo Miocárdico , Valor Preditivo dos Testes , Encaminhamento e Consulta , Humanos , Estudos Retrospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Estenose Coronária/fisiopatologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Angina Estável/fisiopatologia , Angina Estável/diagnóstico por imagem , Angina Estável/terapia , Imagem de Perfusão do Miocárdio/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Algoritmos , Prognóstico , Tomografia Computadorizada Multidetectores , Seleção de Pacientes , Índice de Gravidade de Doença , Revascularização Miocárdica
10.
Circ Cardiovasc Imaging ; 17(10): e017112, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39328060

RESUMO

BACKGROUND: A recent simulation study proposed that stenosis measurements on coronary computed tomography (CT) angiography are influenced by the improved spatial resolution of photon-counting detector (PCD)-CT. The aim of the current study was to evaluate the impact of ultrahigh-spatial-resolution (UHR) on coronary stenosis measurements and Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification rates in patients undergoing coronary CT angiography on both PCD-CT and energy-integrating detector (EID)-CT and to compare measurements against quantitative coronary angiography. METHODS: Patients with coronary calcification on EID-CT (collimation, 192×0.6 mm) were prospectively enrolled for a research coronary CT angiography with UHR PCD-CT (collimation, 120×0.2 mm) within 30 days (between April 1, 2023 and January 31, 2024). PCD-CT was acquired with the same or lower CT dose index and equivalent contrast media volume as EID-CT. Percentage diameter stenosis (PDS) for calcified, partially calcified, and noncalcified lesions were compared between scanners. Patient-level reclassification rates for CAD-RADS were evaluated. The accuracy of PDS measurements was validated against quantitative coronary angiography in patients who underwent invasive coronary angiography. RESULTS: In total, PDS of 278 plaques were quantified in 49 patients (calcified, 202; partially calcified, 51; noncalcified, 25). PCD-CT-based PDS values were lower than EID-CT measurements for calcified (45.1±20.7 versus 54.6±19.2%; P<0.001) and partially calcified plaques (44.3±19.6 versus 54.9±20.0%; P<0.001), without significant differences for noncalcified lesions (39.1±15.2 versus 39.0±16.0%; P=0.98). The reduction in stenosis degrees led to a 49.0% (24/49) reclassification rate to a lower CAD-RADS with PCD-CT. In a subset of 12 patients with 56 lesions, UHR-based PDS values showed higher agreement with quantitative coronary angiography (mean difference, 7.3%; limits of agreement, -10.7%/25.2%) than EID-CT measurements (mean difference, 17.4%; limits of agreement, -6.9%/41.7%). CONCLUSIONS: Compared with conventional EID-CT, UHR PCD-CT results in lower PDS values and more accurate stenosis measurements in coronary plaques with calcified components and leads to a substantial Coronary Artery Disease Reporting and Data System reclassification rate in 49.0% of patients.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária , Humanos , Estenose Coronária/diagnóstico por imagem , Masculino , Feminino , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Vasos Coronários/diagnóstico por imagem , Fótons , Índice de Gravidade de Doença , Calcificação Vascular/diagnóstico por imagem
11.
Am J Physiol Heart Circ Physiol ; 327(4): H1124-H1131, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39240257

RESUMO

Fractional flow reserve (FFR) measurements are recommended for assessing hemodynamic coronary stenosis severity. Intracoronary ECG (icECG) is easily obtainable and highly sensitive in detecting myocardial ischemia due to its close vicinity to the myocardium. We hypothesized that the remission time of myocardial ischemia on icECG after a controlled coronary occlusion accurately detects hemodynamically relevant coronary stenosis. This retrospective, observational study included patients with chronic coronary syndrome undergoing hemodynamic coronary stenosis assessment immediately following a strictly 1-min proximal coronary artery balloon occlusion with simultaneous icECG recording. icECG was used for a beat-to-beat analysis of the ST-segment shift during reactive hyperemia immediately following balloon deflation. The time from coronary balloon deflation until the ST-segment shift reached 37% of its maximum level, i.e., icECG ST-segment shift remission time (τ-icECG in seconds), was obtained by an automatic algorithm. τ-icECG was tested against the simultaneously obtained reactive hyperemia FFR at a threshold of 0.80 as a reference parameter. From 120 patients, 139 icECGs (age, 68 ± 10 yr old) were analyzed. Receiver operating characteristic (ROC) analysis of τ-icECG for the detection of hemodynamically relevant coronary stenosis at an FFR of ≤0.80 was performed. The area under the ROC curve was equal to 0.621 (P = 0.0363) at an optimal τ-icECG threshold of 8 s (sensitivity, 61%; specificity, 67%). τ-icECG correlated inversely and linearly with FFR (P = 0.0327). This first proof-of-concept study demonstrates that τ-icECG, a measure of icECG ST segment-shift remission after a 1-min coronary artery balloon occlusion accurately detects hemodynamically relevant coronary artery stenosis according to FFR at a threshold of ≥8 s.NEW & NOTEWORTHY Invasive hemodynamic measurements are recommended by the current cardiology guidelines to guide percutaneous coronary interventions in the setting of chronic coronary syndrome. However, those pressure-derived indices demonstrate several theoretical and practical limitations. Thus, this study demonstrates the accuracy of a novel, pathophysiology-driven approach using intracoronary ECG for the identification of hemodynamically relevant coronary lesions by quantitatively assessing myocardial ischemia remission.


Assuntos
Estenose Coronária , Eletrocardiografia , Reserva Fracionada de Fluxo Miocárdico , Hemodinâmica , Hiperemia , Humanos , Hiperemia/fisiopatologia , Masculino , Feminino , Idoso , Estenose Coronária/fisiopatologia , Estenose Coronária/diagnóstico , Estenose Coronária/terapia , Estudos Retrospectivos , Pessoa de Meia-Idade , Índice de Gravidade de Doença , Valor Preditivo dos Testes , Fatores de Tempo , Vasos Coronários/fisiopatologia , Cateterismo Cardíaco
12.
BMC Med Imaging ; 24(1): 243, 2024 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-39285323

RESUMO

BACKGROUND: In recent years, as deep learning has received widespread attention in the field of heart disease, some studies have explored the potential of deep learning based on coronary angiography (CAG) or coronary CT angiography (CCTA) images in detecting the extent of coronary artery stenosis. However, there is still a lack of a systematic understanding of its diagnostic accuracy, impeding the advancement of intelligent diagnosis of coronary artery stenosis. Therefore, we conducted this study to review the accuracy of image-based deep learning in detecting coronary artery stenosis. METHODS: We retrieved PubMed, Cochrane, Embase, and Web of Science until April 11, 2023. The risk of bias in the included studies was appraised using the QUADAS-2 tool. We extracted the accuracy of deep learning in the test set and performed subgroup analyses by binary and multiclass classification scenarios. We performed a subgroup analysis based on different degrees of stenosis and applied a double arcsine transformation to process the data. The analysis was done by using R. RESULTS: Our systematic review finally included 18 studies, involving 3568 patients and 13,362 images. In the included studies, deep learning models were constructed based on CAG and CCTA. In binary classification tasks, the accuracy for detecting > 25%, > 50% and > 70% degrees of stenosis at the vessel level were 0.81 (95% CI: 0.71-0.85), 0.73 (95% CI: 0.58-0.88) and 0.61 (95% CI: 0.56-0.65), respectively. In multiclass classification tasks, the accuracy for detecting 0-25%, 25-50%, 50-70%, and 70-100% degrees of stenosis at the vessel level were 0.78 (95% CI: 0.73-0.84), 0.86 (95% CI: 0.78-0.93), 0.83 (95% CI: 0.70-0.97), and 0.70 (95% CI: 0.42-0.98), respectively. CONCLUSIONS: Our study shows that deep learning models based on CAG and CCTA appear to be relatively accurate in diagnosing different degrees of coronary artery stenosis. However, for various degrees of stenosis, their accuracy still needs to be further improved.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária , Aprendizado Profundo , Humanos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Diagnóstico Diferencial
13.
Open Heart ; 11(2)2024 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-39349050

RESUMO

AIMS: To assess the diagnostic accuracy of dobutamine stress echocardiography (DSE) in symptomatic patients with a low to intermediate pretest probability of obstructive coronary artery disease (CAD) and a positive coronary CT angiography (CCTA). METHODS: We prospectively enrolled 104 consecutive patients undergoing coronary angiography for symptoms of stable CAD and a CCTA indicative of obstructive CAD. The diagnostic performance of DSE was evaluated against two intracoronary pressure indices: (a) fractional flow reserve (FFR) with a cut-off of ≤0.80 and (b) instantaneous wave-free ratio (iFR) with a cut-off of ≤0.89, indicating haemodynamically significant stenoses. RESULTS: Of 102 patients, 46 (45%) had at least one significant lesion as defined by FFR, as did 37 (36%) as defined by iFR. DSE showed positive results in 33% (34/102) of cases. The discriminative power of DSE for detecting significant CAD was moderate, with areas under the curve of 0.63 (p=0.024) compared with FFR and 0.64 (p=0.025) compared with iFR. The accuracy, sensitivity and specificity of DSE were, respectively, 61%, 43%, and 75% against FFR, and 64%, 46% and 74% against iFR. The diagnostic accuracy of DSE did not differ significantly between FFR and iFR as a reference (p=0.549). CONCLUSION: In patients with positive CCTA, DSE has a moderate ability to identify haemodynamically significant CAD, with low sensitivity and moderate specificity. When assessed against FFR and iFR criteria, its additive diagnostic value is limited in patients with low to intermediate pretest probability of obstructive CAD. TRIAL REGISTRATION NUMBER: NCT03045601.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Ecocardiografia sob Estresse , Reserva Fracionada de Fluxo Miocárdico , Valor Preditivo dos Testes , Humanos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Masculino , Feminino , Ecocardiografia sob Estresse/métodos , Ecocardiografia sob Estresse/normas , Estudos Prospectivos , Angiografia Coronária/métodos , Pessoa de Meia-Idade , Idoso , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico , Reprodutibilidade dos Testes , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Tomografia Computadorizada/normas , Estenose Coronária/fisiopatologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Dobutamina/administração & dosagem , Padrões de Referência
14.
Am J Cardiol ; 231: 40-47, 2024 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-39245334

RESUMO

The role of lipoprotein (a) (Lp[a]) in the development of obstructive coronary artery disease (CAD) and high-risk plaque (HRP) in primary prevention patients with stable chest pain is unknown. We sought to evaluate the relation of Lp(a), independent of low-density lipoprotein cholesterol (LDL-C), with the presence of obstructive CAD and HRP to improve understanding of the residual risk imparted by Lp(a) on CAD. We performed a secondary analysis in Prospective Multicenter Imaging Study for Evaluation of Chest Pain (PROMISE) Trial participants who had coronary computed tomographic angiography (CTA) performed and Lp(a) data available. Lp(a) concentration was analyzed as a binary variable, with elevated Lp(a) defined as ≥50 mg/100 ml. "Stenosis ≥50%" was defined as ≥50% coronary artery stenosis in any epicardial vessel, and "stenosis ≥70%" was defined as ≥70% coronary artery stenosis in any epicardial vessel and/or ≥50% left main coronary artery stenosis. HRP was defined as presence of plaque on CTA imaging with evidence of positive remodeling, low computed tomography attenuation, or napkin-ring sign. Multivariate logistic regression models were constructed to evaluate the association between Lp(a) and the outcomes of obstructive CAD and HRP stratified by LDL-C ≥100 versus <100 mg/100 ml. Of the 1,815 patients who underwent CTA and had Lp(a) data available, those with elevated Lp(a) were more commonly women and Black than those with lower Lp(a). Elevated Lp(a) was associated with stenosis ≥50% (odds ratio 1.57, 95% confidence interval 1.14 to 2.15, p = 0.005) and stenosis ≥70% (odds ratio 2.05, 95% confidence interval 1.34 to 3.11, p = 0.0008) in the multivariate models, and this relation was not modified by LDL-C ≥100 versus <100 mg/100 ml (interaction p >0.4). Elevated Lp(a) was not associated with HRP when adjusted for obstructive CAD. This study of patients without known CAD found that elevated Lp(a) ≥50 mg/100 ml was independently associated with the presence of obstructive CAD regardless of controlled versus uncontrolled LDL-C but was not independently associated with HRP when stenosis ≥50% or ≥70% was accounted for. Further research is warranted to delineate the role of Lp(a) in the residual risk for atherosclerotic cardiovascular disease that patients may have despite optimal LDL-C lowering.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Lipoproteína(a) , Placa Aterosclerótica , Humanos , Lipoproteína(a)/sangue , Feminino , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/sangue , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/epidemiologia , Estudos Prospectivos , Idoso , LDL-Colesterol/sangue , Estenose Coronária/sangue , Estenose Coronária/diagnóstico por imagem , Fatores de Risco , Biomarcadores/sangue , Prevenção Primária/métodos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Rosuvastatina Cálcica/uso terapêutico
15.
J Pak Med Assoc ; 74(9): 1598-1602, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39279060

RESUMO

OBJECTIVE: To assess long-term clinical outcomes and factors associated with target vessel revascularisation in patients with deferred revascularisation based on negative fractional flow reserve and negative instantaneous wave-free ratio. METHODS: The longitudinal, retrospective study was conducted from July 1, 2020, to January 1, 2022, at the Aga Khan University Hospital, Karachi, and comprised medical records from January 2012 to January 2020 of patients with deferred revascularisation having intermediate to severe coronary lesions on coronary angiogram and had negative fractional flow reserve >0.80 or instantaneous wave-free ratio >0.89 and had not undergone immediate or planned revascularisation on the basis of negative physiological assessment. Data was collected from the institutional records, while final follow-up was taken by reviewing the medical records or telephonic interviews regarding any major adverse cardiac event after the index procedure. Data was analysed using Stata 14.2. RESULTS: Of the 345 patients, 245(71%) were males. The overall mean age was 62±11 years. There were 194(56%) patients who presented with stable angina and 151(44%) presented with acute coronary syndrome. Mean fractional flow reserve was 0.87±0.04 and mean instantaneous wave-free ratio was 0.93±0.03. Multivessel disease was present in 223(65%) patients. Median follow-up period was 29 months (IQR: 24-36 months). Major adverse cardiovascular events occurred in 22(6%) patients, and target vessel revascularisation was required in 11(3%). Diabetes and percentage of stenosis were found to be independent predictors of major adverse cardiovascular events (p<0.05). CONCLUSIONS: Deferral of revascularisation and opting for medical treatment for coronary artery stenosis with higher fractional flow reserve or instantaneous wave-free ratio could be considered a safe and reasonable strategy.


Assuntos
Angiografia Coronária , Reserva Fracionada de Fluxo Miocárdico , Revascularização Miocárdica , Humanos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Masculino , Feminino , Pessoa de Meia-Idade , Paquistão/epidemiologia , Estudos Retrospectivos , Idoso , Revascularização Miocárdica/métodos , Revascularização Miocárdica/estatística & dados numéricos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/fisiopatologia , Estudos Longitudinais , Estenose Coronária/fisiopatologia , Estenose Coronária/cirurgia , Síndrome Coronariana Aguda/cirurgia , Síndrome Coronariana Aguda/fisiopatologia , Angina Estável/cirurgia , Angina Estável/fisiopatologia , Resultado do Tratamento , Intervenção Coronária Percutânea/métodos
19.
G Ital Cardiol (Rome) ; 25(10): 747-751, 2024 Oct.
Artigo em Italiano | MEDLINE | ID: mdl-39342559

RESUMO

The presence of metastatic cancer represents a high-risk condition for the treatment of heart disease requiring surgical or percutaneous procedures. We present the case of a 58-year-old man with pulmonary adenocarcinoma and renal metastases surviving more than 3 years after chemotherapy and immunotherapy suffering dyspnea and chest pain on minimal exertion due to 99% anterior coronary artery stenosis associated with severe aortic stenosis of a bicuspid valve. We treated the cardiac lesions in two steps by coronary angioplasty with drug-eluting stent implantation followed by percutaneous prosthetic aortic valve replacement. The procedures were successful with resolution of the symptoms and recovery of the usual ECOG-PS 0-1 functional capacity which persists 24 months after cardiac procedures. This case demonstrates that the multidisciplinary collaboration between oncologists and cardiologists with a personalized patient-centered approach allows to treat complex clinical situations successfully in the emerging category of patients surviving with metastatic cancer.


Assuntos
Estenose da Valva Aórtica , Carcinoma Pulmonar de Células não Pequenas , Stents Farmacológicos , Neoplasias Pulmonares , Humanos , Masculino , Neoplasias Pulmonares/secundário , Neoplasias Pulmonares/terapia , Neoplasias Pulmonares/patologia , Pessoa de Meia-Idade , Carcinoma Pulmonar de Células não Pequenas/terapia , Estenose da Valva Aórtica/cirurgia , Estadiamento de Neoplasias , Sobreviventes de Câncer , Estenose Coronária/terapia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Neoplasias Renais/patologia , Neoplasias Renais/terapia , Adenocarcinoma/terapia , Angioplastia Coronária com Balão/métodos
20.
J Int Med Res ; 52(9): 3000605241285229, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39324187

RESUMO

The hallmark of Wellens' syndrome is a distinct modification in the precordial T wave of the electrocardiogram (ECG), which usually indicates substantial stenosis of the proximal left anterior descending artery (LAD). Patients with Wellens' syndrome commonly do not exhibit any symptoms of chest pain. This current case report describes a male patient in his early 60s who presented with sporadic chest pain who was subsequently diagnosed with Wellens' syndrome-related electrocardiographic abnormalities. In the precordial leads V2-V5, an inverted symmetric T wave was visible on the asymptomatic ECG. The inverted symmetric T wave of the precordial lead V2-V5 reverted back to being upright when the chest pain started. A follow-up ECG performed before emergency surgery revealed ventricular premature beats and an increase of 0.1-0.5 mV in the ST segment of the precordial leads V1-V5. A drug-eluting stent was inserted after the patient's coronary angiography revealed proximal stenosis of the LAD. To prevent acute myocardial infarction, emergency physicians must identify the ECG signs of Wellens' syndrome and treat high-risk patients with revascularization as soon as feasible. Early recognition and proactive intervention are crucial, as they may help to alleviate adverse consequences.


Assuntos
Angiografia Coronária , Eletrocardiografia , Humanos , Masculino , Pessoa de Meia-Idade , Dor no Peito/etiologia , Dor no Peito/diagnóstico , Stents Farmacológicos , Estenose Coronária/cirurgia , Estenose Coronária/diagnóstico , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/cirurgia , Síndrome , Infarto Miocárdico de Parede Anterior/diagnóstico , Infarto Miocárdico de Parede Anterior/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...