Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22.914
Filtrar
2.
Genes (Basel) ; 15(6)2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38927607

RESUMO

Cardiac remodeling and ventricular pacing represent intertwined phenomena with profound implications for cardiovascular health and therapeutic interventions. This review explores the intricate relationship between cardiac remodeling and ventricular pacing, spanning from the molecular underpinnings to biomechanical alterations. Beginning with an examination of genetic predispositions and cellular signaling pathways, we delve into the mechanisms driving myocardial structural changes and electrical remodeling in response to pacing stimuli. Insights into the dynamic interplay between pacing strategies and adaptive or maladaptive remodeling processes are synthesized, shedding light on the clinical implications for patients with various cardiovascular pathologies. By bridging the gap between basic science discoveries and clinical translation, this review aims to provide a comprehensive understanding of cardiac remodeling in the context of ventricular pacing, paving the way for future advancements in cardiovascular care.


Assuntos
Remodelação Ventricular , Humanos , Remodelação Ventricular/genética , Animais , Ventrículos do Coração/fisiopatologia , Estimulação Cardíaca Artificial/métodos
3.
Biosens Bioelectron ; 261: 116453, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38850739

RESUMO

Implantable cardiac pacemakers are crucial therapeutic tools for managing various cardiac conditions. For effective pacing, electrodes should exhibit flexibility, deformability, biocompatibility, and high conductivity/capacitance. Laser-induced graphene (LIG) shows promise due to its exceptional electrical and electrochemical properties. However, the fragility of LIG and the non-stretchability of polyimide substrates pose challenges when interfacing with the beating heart. Here, we present a simple method for fabricating robust, flexible, and stretchable bioelectronic interfaces by transferring LIG via water-responsive, nonswellable polyvinyl alcohol (PVA) gels. PVA solution penetrates the porous structure of LIG and solidifies into PVA xerogel as the solvent evaporates. The robust PVA xerogel enables the smooth transfer of LIG and prevents stretching of the LIG network during this process, which helps maintain its conductivity. When hydrated, the xerogel becomes a stable, nonswellable hydrogel. This gives the LIG-PVA hydrogel (LIG-PVA-H) composites with excellent conductivity (119.7 ± 4.3Ω sq-1), high stretchability (up to 420%), reliability (cyclic stretch under 15% strain, with ∼ 1-time resistance increase), and good stability in phosphate buffered saline. The LIG-PVA-H composites were used as biointerfaces for electrocardiogram signal recording and electrical pacing on rat hearts ex vivo and in vivo, using commercial setups and a custom-built implantable wireless device. This work expands the application of LIG in bioelectronic interfaces and facilitates the development of electrotherapy for cardiac diseases.


Assuntos
Técnicas Biossensoriais , Grafite , Lasers , Álcool de Polivinil , Grafite/química , Álcool de Polivinil/química , Animais , Ratos , Condutividade Elétrica , Água/química , Marca-Passo Artificial , Estimulação Cardíaca Artificial , Géis/química , Ratos Sprague-Dawley
5.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38874449

RESUMO

Ventricular backup leads may be considered in selected patients with His bundle pacing (HBP), but it remains unknown to what extent this is useful. A total of 184 HBP patients were studied. At last follow-up, 147 (79.9%) patients retained His bundle capture at programmed output. His bundle pacing lead revision was performed in 5/36 (13.9%) patients without a backup lead and in 3/148 (2.0%) patients with a backup lead (P = 0.008). One patient without a backup lead had syncope due to atrial oversensing. Thus, implantation of ventricular backup leads may avoid lead revision and adverse events in selected HBP patients.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Humanos , Fascículo Atrioventricular/fisiopatologia , Masculino , Feminino , Estimulação Cardíaca Artificial/métodos , Idoso , Resultado do Tratamento , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Fatores de Tempo , Eletrodos Implantados
6.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38938169

RESUMO

AIMS: Subclinical atrial fibrillation (AF) is associated with increased risk of progression to clinical AF, stroke, and cardiovascular death. We hypothesized that in pacemaker patients requiring dual-chamber rate-adaptive (DDDR) pacing, closed loop stimulation (CLS) integrated into the circulatory control system through intra-cardiac impedance monitoring would reduce the occurrence of atrial high-rate episodes (AHREs) compared with conventional DDDR pacing. METHODS AND RESULTS: Patients with sinus node dysfunctions (SNDs) and an implanted pacemaker or defibrillator were randomly allocated to dual-chamber CLS (n = 612) or accelerometer-based DDDR pacing (n = 598) and followed for 3 years. The primary endpoint was time to the composite endpoint of the first AHRE lasting ≥6 min, stroke, or transient ischaemic attack (TIA). All AHREs were independently adjudicated using intra-cardiac electrograms. The incidence of the primary endpoint was lower in the CLS arm (50.6%) than in the DDDR arm (55.7%), primarily due to the reduction in AHREs lasting between 6 h and 7 days. Unadjusted site-stratified hazard ratio (HR) for CLS vs. DDDR was 0.84 [95% confidence interval (CI), 0.72-0.99; P = 0.035]. After adjusting for CHA2DS2-VASc score, the HR remained 0.84 (95% CI, 0.71-0.99; P = 0.033). In subgroup analyses of AHRE incidence, the incremental benefit of CLS was greatest in patients without atrioventricular block (HR, 0.77; P = 0.008) and in patients without AF history (HR, 0.73; P = 0.009). The contribution of stroke/TIA to the primary endpoint (1.3%) was low and not statistically different between study arms. CONCLUSION: Dual-chamber CLS in patients with SND is associated with a significantly lower AHRE incidence than conventional DDDR pacing.


Assuntos
Fibrilação Atrial , Estimulação Cardíaca Artificial , Frequência Cardíaca , Ataque Isquêmico Transitório , Marca-Passo Artificial , Síndrome do Nó Sinusal , Acidente Vascular Cerebral , Humanos , Feminino , Masculino , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/epidemiologia , Idoso , Síndrome do Nó Sinusal/terapia , Síndrome do Nó Sinusal/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Ataque Isquêmico Transitório/prevenção & controle , Ataque Isquêmico Transitório/epidemiologia , Pessoa de Meia-Idade , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/epidemiologia , Incidência , Resultado do Tratamento , Fatores de Tempo , Fatores de Risco , Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas , Acelerometria , Idoso de 80 Anos ou mais
7.
Comput Methods Programs Biomed ; 253: 108239, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38823116

RESUMO

BACKGROUND: The excitable gap (EG), defined as the excitable tissue between two subsequent wavefronts of depolarization, is critical for maintaining reentry that underlies deadly ventricular arrhythmias. EG in the His-Purkinje Network (HPN) plays an important role in the maintenance of electrical wave reentry that underlies these arrhythmias. OBJECTIVE: To determine if rapid His bundle pacing (HBP) during reentry reduces the amount of EG in the HPN and ventricular myocardium to suppress reentry maintenance and/or improve defibrillation efficacy. METHODS: In a virtual human biventricular model, reentry was initiated with rapid line pacing followed by HBP delivered for 3, 6, or 9 s at pacing cycle lengths (PCLs) ranging from 10 to 300 ms (n=30). EG was calculated independently for the HPN and myocardium over each PCL. Defibrillation efficacy was assessed for each PCL by stimulating myocardial surface EG with delays ranging from 0.25 to 9 s (increments of 0.25 s, n=36) after the start of HBP. Defibrillation was successful if reentry terminated within 1 s after EG stimulation. This defibrillation protocol was repeated without HBP. To test the approach under different pathological conditions, all protocols were repeated in the model with right (RBBB) or left (LBBB) bundle branch block. RESULTS: Compared to without pacing, HBP for >3 seconds reduced average EG in the HPN and myocardium across a broad range of PCLs for the default, RBBB, and LBBB models. HBP >6 seconds terminated reentrant arrhythmia by converting HPN activation to a sinus rhythm behavior in the default (6/30 PCLs) and RBBB (7/30 PCLs) models. Myocardial EG stimulation during HBP increased the number of successful defibrillation attempts by 3%-19% for 30/30 PCLs in the default model, 3%-6% for 14/30 PCLs in the RBBB model, and 3%-11% for 27/30 PCLs in the LBBB model. CONCLUSION: HBP can reduce the amount of excitable gap and suppress reentry maintenance in the HPN and myocardium. HBP can also improve the efficacy of low-energy defibrillation approaches targeting excitable myocardium. HBP during reentrant arrhythmias is a promising anti-arrhythmic and defibrillation strategy.


Assuntos
Fascículo Atrioventricular , Humanos , Fascículo Atrioventricular/fisiopatologia , Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial/métodos , Cardioversão Elétrica/métodos , Ventrículos do Coração/fisiopatologia , Modelos Cardiovasculares
8.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38866455

RESUMO

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Estimulação Cardíaca Artificial , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Fatores de Risco , Idoso , Fatores de Tempo , Idoso de 80 Anos ou mais , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Medição de Risco , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Estados Unidos/epidemiologia
10.
Air Med J ; 43(4): 357-359, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38897701

RESUMO

Point-of-care ultrasound (POCUS) is a safe diagnostic tool that clinicians use to rapidly evaluate critically ill patients.1 POCUS has expanded into the prehospital setting and has been demonstrated to be accurate, feasible, and helpful in guiding clinical decision making.2-4 Additionally, the American College of Emergency Physicians recommends the use of echocardiography to evaluate for ventricular activity in the setting of cardiac arrest.5 There is minimal evidence regarding the use of POCUS to confirm mechanical capture in patients undergoing transcutaneous pacing. This case report highlights the use of POCUS in a patient with bradyasystolic cardiac arrest requiring transcutaneous pacing. Despite electrical capture, the patient had absent central pulses; however, POCUS demonstrated ventricular contractions, indicating mechanical capture. This suggests a role for POCUS for the evaluation of mechanical capture in patients undergoing cardiac pacing.


Assuntos
Estimulação Cardíaca Artificial , Ecocardiografia , Serviços Médicos de Emergência , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Serviços Médicos de Emergência/métodos , Ecocardiografia/métodos , Estimulação Cardíaca Artificial/métodos , Masculino , Parada Cardíaca Extra-Hospitalar/terapia , Parada Cardíaca Extra-Hospitalar/diagnóstico por imagem , Ultrassonografia/métodos , Bradicardia/terapia , Idoso
11.
Kardiol Pol ; 82(6): 632-639, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38712772

RESUMO

BACKGROUND: Left bundle branch area pacing (LBBAP) demonstrated beneficial effects on clinical outcomes. Comparative data on the risk of atrial high-rate episodes (AHREs) between LBBAP and right ventricular pacing (RVP) are lacking. AIMS: This study aimed to investigate whether LBBAP can reduce the risk of new-onset AHREs compared with RVP in patients with atrioventricular block (AVB). METHODS: We enrolled 175 consecutive AVB patients with no history of atrial fibrillation undergoing dual-chamber pacemaker implantation (LBBAP or RVP). Propensity score matching for baseline characteristics yielded 43 matched pairs. The primary outcome was new-onset AHREs detected on a scheduled device follow-up. Changes in echocardiographic measurements were also compared between the groups. RESULTS: New-onset AHREs occurred in 42 (24.0%) of all enrolled patients (follow-up 14.1 [7.5] months) and the incidence of new-onset AHREs in the LBBAP group was lower than in the RVP group (19.8% vs. 34.7%; P = 0.04). After propensity score matching, LBBAP still resulted in a lower incidence of new-onset AHREs (11.6% vs. 32.6%; P = 0.02), and a lower hazard ratio for new-onset AHREs compared with RVP (HR, 0.274; 95% CI, 0.113-0.692). At 1 year, LBBAP achieved preserved left ventricular ejection fraction (LVEF) (63.0 [3.2]% to 63.1 [3.1]%; P = 0.56), while RVP resulted in reduced LVEF (63.4 [4.9]% to 60.5 [7.3]%; P = 0.01]). Changes in LVEF were significantly different between the 2 groups (by 2.6% [0.2 to 5.0]%; P = 0.03). CONCLUSION: LBBAP demonstrated a reduced risk of new-onset AHREs compared with RVP in patients with AVB.


Assuntos
Bloqueio Atrioventricular , Estimulação Cardíaca Artificial , Humanos , Masculino , Feminino , Bloqueio Atrioventricular/terapia , Idoso , Estimulação Cardíaca Artificial/métodos , Pessoa de Meia-Idade , Ventrículos do Coração/fisiopatologia , Idoso de 80 Anos ou mais , Fibrilação Atrial/terapia , Resultado do Tratamento
14.
J Cardiovasc Med (Hagerstown) ; 25(7): 551-558, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38809231

RESUMO

AIMS: In patients undergoing pacemaker implantation with no prior history of heart failure (HF), the presence of left bundle branch block (LBBB) has been identified as an independent predictor of HF-related death or hospitalization, while the prognostic significance of right bundle branch block (RBBB) remains uncertain. We aimed to assess the long-term risk of all-cause mortality in patients with a standard indication for permanent pacing and normal or moderately depressed left ventricular function when RBBB is detected at the time of implantation. METHODS: We retrospectively enrolled 1348 consecutive patients who had undergone single- or dual-chamber pacemaker implantation at the study center, from January 1990 to December 2022. Patients with a left ventricular ejection fraction ≤35% or a prior diagnosis of HF were excluded. RESULTS: The baseline 12-lead electrocardiogram revealed an RBBB in 241 (18%) and an LBBB in 98 (7%) patients. During a median follow-up of 65 [25th-75th percentile: 32-117] months, 704 (52%) patients died. The combined endpoint of cardiovascular death or HF hospitalization was reached by 173 (13%) patients. On multivariate analysis, RBBB was confirmed as an independent predictor of death [hazard ratio, 1.33; 95% confidence interval (CI), 1.09-1.63; P  = 0.005]. However, when considering the combined endpoint of cardiovascular death and HF hospitalization, this endpoint was independently associated with LBBB (hazard ratio, 2.13; 95% CI, 1.38-3.29; P  < 0.001), but not with RBBB. CONCLUSION: In patients with standard pacemaker indications and normal or moderately depressed left ventricular function, the presence of basal RBBB was an independent predictor of mortality. However, it was not associated with the combined endpoint of cardiovascular death and HF hospitalization.


Assuntos
Bloqueio de Ramo , Eletrocardiografia , Marca-Passo Artificial , Humanos , Bloqueio de Ramo/terapia , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/mortalidade , Bloqueio de Ramo/diagnóstico , Masculino , Feminino , Idoso , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Estimulação Cardíaca Artificial/mortalidade , Fatores de Risco , Função Ventricular Esquerda , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Fatores de Tempo , Hospitalização/estatística & dados numéricos , Pessoa de Meia-Idade , Prognóstico , Medição de Risco/métodos , Resultado do Tratamento , Relevância Clínica
15.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38703372

RESUMO

AIMS: To characterize the diagnosis, frequency, and procedural implications of septal venous channel perforation during left bundle branch area pacing (LBBAP). METHODS AND RESULTS: All consecutive patients undergoing LBBAP over an 8-month period were prospectively studied. During lead placement, obligatory septal contrast injection was performed twice, at initiation (implant entry zone) and at completion (fixation zone). An intuitive fluoroscopic schema using orthogonal views (left anterior oblique/right anterior oblique) and familiar landmarks is described. Using this, we resolved zonal distribution (I-VI) of lead position on the ventricular septum and its angulation (post-fixation angle θ). Subjects with and without septal venous channel perforation were compared. Sixty-one patients {male 57.3%, median age [interquartile range (IQR)] 69.5 [62.5-74.5] years} were enrolled. Septal venous channel perforation was observed in eight (13.1%) patients [male 28.5%, median age (IQR) 64 (50-75) years]. They had higher frequency of (i) right-sided implant (25% vs. 1.9%, P = 0.04), (ii) fixation in zone III at the mid-superior septum (75% vs. 28.3%, P = 0.04), (iii) steeper angle of fixation-median θ (IQR) [19 (10-30)° vs. 5 (4-19)°, P = 0.01], and (iv) longer median penetrated-lead length (IQR) [13 (10-14.8) vs. 10 (8.5-12.5) mm, P = 0.03]. Coronary sinus drainage of contrast was noted in five (62.5%) patients. Abnormal impedance drops during implantation (12.5% vs. 5.7%, P = NS) were not significantly different. CONCLUSION: When evaluated systematically, septal venous channel perforation may be encountered commonly after LBBAP. The fiducial reference framework described using fluoroscopic imaging identified salient associated findings. This may be addressed with lead repositioning to a more inferior location and is not associated with adverse consequence acutely or in early follow-up.


Assuntos
Estimulação Cardíaca Artificial , Humanos , Masculino , Feminino , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso , Estimulação Cardíaca Artificial/métodos , Septo Interventricular/diagnóstico por imagem , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/diagnóstico por imagem , Resultado do Tratamento , Fatores de Risco , Fascículo Atrioventricular/fisiopatologia , Septos Cardíacos/diagnóstico por imagem , Meios de Contraste , Fluoroscopia , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/etiologia
16.
Am J Cardiol ; 222: 78-86, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38723856

RESUMO

The underlying mechanisms leading to the development of mitral regurgitation (MR) after right ventricular (RV) pacemaker (PM) implantation and its prognostic value have yet to be fully understood. The purpose of this study was to evaluate the prevalence and clinical variables associated with the development of MR after RV pacing and its association with outcomes. A total of 451 patients (mean age 69 ± 15 years, 61% male) who underwent de novo RV PM implantation were included. The development of significant MR, defined as ≥moderate from mild or none/trace at baseline, occurred in 131 (29%) patients at a median of 2.4 years (interquartile range: 1.0 to 3.8 years) after PM implantation. Multivariate logistic regression analysis demonstrated that implantation of a single-chamber PM, left ventricular end-systolic volume index, and the presence of mild MR (vs no MR) at baseline were independently associated with the development of significant MR post-implant. Cardiac events, defined as the composite of all-cause mortality or heart failure hospitalization, occurred in 143 patients (31.7%) during a median follow-up of 5.4 years (interquartile range: 3.0 to 8.1 years). Multivariate Cox regression analysis demonstrated that the development of significant MR was independently related to the occurrence of cardiac events. In conclusion, the development of significant MR after PM implantation is seen in about one-third of recipients and is independently associated with adverse cardiac events.


Assuntos
Ventrículos do Coração , Insuficiência da Valva Mitral , Marca-Passo Artificial , Humanos , Masculino , Feminino , Idoso , Insuficiência da Valva Mitral/epidemiologia , Prognóstico , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Estudos Retrospectivos , Seguimentos , Pessoa de Meia-Idade , Estimulação Cardíaca Artificial , Fatores de Risco , Idoso de 80 Anos ou mais , Ecocardiografia , Prevalência
17.
Circ Arrhythm Electrophysiol ; 17(6): e012523, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38690665

RESUMO

BACKGROUND: In the PARTITA trial (Does Timing of Ventricular Tachycardia Ablation Affect Prognosis in Patients With an Implantable Cardioverter Defibrillator?), antitachycardia pacing (ATP) predicted the occurrence of implantable cardioverter defibrillator (ICD) shocks. Catheter ablation of ventricular tachycardia after the first shock reduced the risk of death or worsening heart failure. A threshold of ATPs that might warrant an ablation procedure before ICD shocks is unknown. Our aim was to identify a threshold of ATPs and clinical features that predict the occurrence of shocks and cardiovascular events. METHODS: We analyzed data from 517 patients in phase A of the PARTITA study. We used classification and regression tree analysis to develop and test a risk stratification model based on arrhythmia patterns and clinical data to predict ICD shocks. Secondary end points were worsening heart failure and cardiovascular hospitalization. RESULTS: Classification and regression tree classified patients into 6 leaves by increasing shock probability. Patients treated with ≥5 ATPs in 6 months (active arrhythmia pattern) had the highest risk of ICD shocks (93% and 86%, training and testing samples, respectively). Patients without ATPs had the lowest (1% and 2%). Other predictors included left ventricle ejection fraction<35%, age of <60 years, and obesity. Survival analysis revealed a higher risk of worsening heart failure (hazard ratio, 5.45 [95% CI, 1.62-18.4]; P=0.006) and cardiovascular hospitalization (hazard ratio, 7.29 [95% CI, 3.66-14.5]; P<0.001) for patients with an active arrhythmia pattern compared with those without ATPs. CONCLUSIONS: Patients with an active arrhythmia pattern (≥5 ATPs in 6 months) are associated with an increased risk of ICD shocks, as well as heart failure hospitalization and cardiovascular hospitalization. These data suggest that additional treatments may be helpful to this high-risk group as a preventive strategy to reduce the incidence of major events. Further prospective randomized trials are needed to confirm the benefits of early ventricular tachycardia ablation in this setting.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Insuficiência Cardíaca , Taquicardia Ventricular , Humanos , Feminino , Masculino , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/mortalidade , Pessoa de Meia-Idade , Idoso , Fatores de Risco , Medição de Risco , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Ablação por Cateter/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Estimulação Cardíaca Artificial/efeitos adversos
18.
Neurosurg Rev ; 47(1): 215, 2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38730072

RESUMO

BACKGROUND AND OBJECTIVES: Cerebral aneurysms in complex anatomical locations and intraoperative rupture can be challenging. Many methods to reduce blood flow can facilitate its exclusion from the circulation. This study evaluated the safety and efficacy of using adenosine, rapid ventricular pacing, and hypothermia in cerebral aneurysm clipping. METHODS: Databases (PubMed, Embase, and Web of Science) were systematically searched for studies documenting the use of adenosine, rapid ventricular pacing, and hypothermia in cerebral aneurysm clipping and were included in this single-arm meta-analysis. The primary outcome was 30-day mortality. Secondary outcomes included neurological outcomes by mRs and GOS, and cardiac outcomes. We evaluated the risk of bias using ROBIN-I, a tool developed by the Cochrane Collaboration. OpenMetaAnalyst version 2.0 was used for statistical analysis and I2 measured data heterogeneity. Heterogeneity was defined as an I2 > 50%. RESULTS: Our systematic search yielded 10,100 results. After the removal of duplicates and exclusion by title and abstract, 64 studies were considered for full review, of which 29 were included. The overall risk of bias was moderate. The pooled proportions of the adenosine analysis for the different outcomes were: For the primary outcome: 11,9%; for perioperative arrhythmia: 0,19%; for postoperative arrhythmia: 0,56%; for myocardial infarction incidence: 0,01%; for follow-up good recovery (mRs 0-2): 88%; and for neurological deficit:14.1%. In the rapid ventricular pacing analysis, incidences were as follows: peri operative arrhythmia: 0,64%; postoperative arrhythmia: 0,3%; myocardial infarction: 0%. In the hypothermia analysis, the pooled proportion of 30-day mortality was 11,6%. The incidence of post-op neurological deficits was 35,4% and good recovery under neurological analysis by GOS was present in 69.2%. CONCLUSION: The use of the three methods is safe and the related complications were very low. Further studies are necessary, especially with comparative analysis, for extended knowledge.


Assuntos
Adenosina , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/cirurgia , Adenosina/uso terapêutico , Hipotermia Induzida/métodos , Resultado do Tratamento , Procedimentos Neurocirúrgicos/métodos , Estimulação Cardíaca Artificial/métodos
19.
Med Sci Monit ; 30: e944114, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38776271

RESUMO

BACKGROUND Long-term right ventricular (RV) pacing has been linked to left atrial enlargement (LAE). The incidence and risk factors associated with significant LAE after RV pacing remain unknown. This retrospective study included 461 patients requiring RV pacing at 2 centers between 2012 and 2020 and aimed to evaluate the incidence, risk factors, outcomes, and complications of LAE. MATERIAL AND METHODS A total of 461 patients with normal-sized pre-implant left atrial dimension and dual-chamber pacing pacemaker implantation for complete atrioventricular block were enrolled. Patients were grouped based on a ≥20% increase from their baseline left atrial dimension by echocardiography, indicating significant LAE, and initial characteristics, echocardiographic data, and outcomes were compared. RESULTS During a mean 7.0±4.9 years follow-up period, 96 patients (20.8%) developed significant LAE, whereas 365 patients did not. In multivariate logistic regression analysis, smaller pre-implant left atrial dimension (OR, 0.776; 95% CI, 0.728-0.828; P<0.001), lower post-implant left ventricular ejection fraction (OR, 0.976; 95% CI, 0.957-0.995; P=0.014), post-implant development of moderate to severe mitral regurgitation (OR, 2.357; 95% CI, 1.172-4.740; P=0.016), and RV pacing duration ≥3.3 years (OR, 1.576; 95% CI, 1.039-2.646; P=0.045) were independent predictors of significant LAE after RV-dependent pacing. There was a significant difference in the incident stroke events between patients without and with significant LAE (9.9% vs 17.7%; log-rank P=0.047). CONCLUSIONS Long-term RV pacing was linked to significant LAE in 20.8% of patients with complete atrioventricular block, with those affected experiencing a higher stroke rate during follow-up.


Assuntos
Estimulação Cardíaca Artificial , Ecocardiografia , Átrios do Coração , Ventrículos do Coração , Humanos , Feminino , Masculino , Estudos Retrospectivos , Fatores de Risco , Incidência , Idoso , Átrios do Coração/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Estimulação Cardíaca Artificial/efeitos adversos , Pessoa de Meia-Idade , Ventrículos do Coração/fisiopatologia , Ecocardiografia/métodos , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/fisiopatologia , Cardiomegalia/fisiopatologia , Marca-Passo Artificial , Resultado do Tratamento , Idoso de 80 Anos ou mais
20.
BMC Cardiovasc Disord ; 24(1): 246, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730404

RESUMO

BACKGROUND: Clinical outcomes after catheter ablation (CA) or pacemaker (PM) implantation for the tachycardia-bradycardia syndrome (TBS) has not been evaluated adequately. We tried to compare the efficacy and safety outcomes of CA and PM implantation as an initial treatment option for TBS in paroxysmal atrial fibrillation (AF) patients. METHODS: Sixty-eight patients with paroxysmal AF and TBS (mean 63.7 years, 63.2% male) were randomized, and received CA (n = 35) or PM (n = 33) as initial treatments. The primary outcomes were unexpected emergency room visits or hospitalizations attributed to cardiovascular causes. RESULTS: In the intention-to-treatment analysis, the rates of primary outcomes were not significantly different between the two groups at the 2-year follow-up (19.8% vs. 25.9%; hazard ratio (HR) 0.73, 95% confidence interval (CI) 0.25-2.20, P = 0.584), irrespective of whether the results were adjusted for age (HR 1.12, 95% CI 0.34-3.64, P = 0.852). The 2-year rate of recurrent AF was significantly lower in the CA group compared to the PM group (33.9% vs. 56.8%, P = 0.038). Four patients (11.4%) in the CA group finally received PMs after CA owing to recurrent syncope episodes. The rate of major or minor procedure related complications was not significantly different between the two groups. CONCLUSION: CA had a similar efficacy and safety profile with that of PM and a higher sinus rhythm maintenance rate. CA could be considered as a preferable initial treatment option over PM implantation in patients with paroxysmal AF and TBS. TRIAL REGISTRATION: KCT0000155.


Assuntos
Fibrilação Atrial , Bradicardia , Estimulação Cardíaca Artificial , Ablação por Cateter , Frequência Cardíaca , Marca-Passo Artificial , Recidiva , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Fibrilação Atrial/cirurgia , Bradicardia/diagnóstico , Bradicardia/terapia , Bradicardia/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Fatores de Tempo , Fatores de Risco , Síndrome , Taquicardia/fisiopatologia , Taquicardia/diagnóstico , Taquicardia/terapia , Taquicardia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...