Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.877
Filtrar
1.
Sci Rep ; 14(1): 15066, 2024 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-38956113

RESUMO

Living cells have spontaneous ultraweak photon emission derived from metabolic reactions associated with physiological conditions. The ORCA-Quest CMOS camera (Hamamatsu Photonics, Japan) is a highly sensitive and essential tool for photon detection; its use with a microscope incubator (Olympus) enables the detection of photons emitted by embryos with the exclusion of harmful visible light. With the application of the second law of thermodynamics, the low-entropy energy absorbed and used by embryos can be distinguished from the higher-entropy energy released and detectable in their environment. To evaluate higher-entropy energy data from embryos, we developed a unique algorithm for the calculation of the entropy-weighted spectral fractal dimension, which demonstrates the self-similar structure of the energy (photons) released by embryos. Analyses based on this structure enabled the distinction of living and degenerated mouse embryos, and of frozen and fresh embryos and the background. This novel detection of ultra-weak photon emission from mouse embryos can provide the basis for the development of a photon emission embryo control system. The ultraweak photon emission fingerprints of embryos may be used for the selection of viable specimens in an ideal dark environment.


Assuntos
Algoritmos , Embrião de Mamíferos , Fótons , Animais , Camundongos , Feminino
2.
Sci Rep ; 14(1): 15459, 2024 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-38965299

RESUMO

Two-photon vision enables near-infrared light perception in humans. We investigate the possibility to utilize this phenomenon as an indicator of the location of the outer segments of photoreceptor cells in the OCT images. Since two-photon vision is independent on OCT imaging, it could provide external to OCT reference relative to which positions of retinal layers visible in OCT imaging could be measured. We show coincidence between OCT imaging of outer retinal layers and two-photon light perception. The experiment utilizes an intrinsic nonlinear process in the retina, two-photon absorption of light by visual photopigments, which triggers perception of near-infrared light. By shifting the focus of the imaging/stimulus beam, we link the peak efficiency of two-photon vision with the visibility of outer segments of photoreceptor cells, which can be seen as in vivo identification of a retinal layer containing visual photopigments in OCT images. Determination of the in-focus retinal layer is achieved by analysis of en face OCT image contrast. We discuss experimental methods and experimental factors that may influence two-photon light perception and the accuracy of the results. The limits of resolution are discussed in analysis of the one-photon and two-photon point spread functions.


Assuntos
Psicofísica , Retina , Tomografia de Coerência Óptica , Tomografia de Coerência Óptica/métodos , Humanos , Retina/diagnóstico por imagem , Retina/fisiologia , Fótons , Percepção Visual/fisiologia
3.
Radiat Oncol ; 19(1): 85, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38956684

RESUMO

BACKGROUND: Radiotherapy is essential in the treatment of prostate cancer. An alternative to conventional photon radiotherapy is the application of carbon ions, which provide a superior intratumoral dose distribution and less induced damage to adjacent healthy tissue. A common characteristic of prostate cancer cells is their dependence on androgens which is exploited therapeutically by androgen deprivation therapy in the advanced prostate cancer stage. Here, we aimed to analyze the transcriptomic response of prostate cancer cells to irradiation by photons in comparison to carbon ions, focusing on DNA damage, DNA repair and androgen receptor signaling. METHODS: Prostate cancer cell lines LNCaP (functional TP53 and androgen receptor signaling) and DU145 (dysfunctional TP53 and androgen receptor signaling) were irradiated by photons or carbon ions and the subsequent DNA damage was assessed by immuno-cytofluorescence. Furthermore, the cells were treated with an androgen-receptor agonist. The effects of irradiation and androgen treatment on the gene regulation and the transcriptome were investigated by RT-qPCR and RNA sequencing, followed by bioinformatic analysis. RESULTS: Following photon or carbon ion irradiation, both LNCaP and DU145 cells showed a dose-dependent amount of visible DNA damage that decreased over time, indicating occurring DNA repair. In terms of gene regulation, mRNAs involved in the TP53-dependent DNA damage response were significantly upregulated by photons and carbon ions in LNCaP but not in DU145 cells, which generally showed low levels of gene regulation after irradiation. Both LNCaP and DU145 cells responded to photons and carbon ions by downregulation of genes involved in DNA repair and cell cycle, partially resembling the transcriptome response to the applied androgen receptor agonist. Neither photons nor carbon ions significantly affected canonical androgen receptor-dependent gene regulation. Furthermore, certain genes that were specifically regulated by either photon or carbon ion irradiation were identified. CONCLUSION: Photon and carbon ion irradiation showed a significant congruence in terms of induced signaling pathways and transcriptomic responses. These responses were strongly impacted by the TP53 status. Nevertheless, irradiation mode-dependent distinct gene regulations with undefined implication for radiotherapy outcome were revealed. Androgen receptor signaling and irradiations shared regulation of certain genes with respect to DNA-repair and cell-cycle.


Assuntos
Fótons , Neoplasias da Próstata , Receptores Androgênicos , Transdução de Sinais , Transcriptoma , Proteína Supressora de Tumor p53 , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/patologia , Receptores Androgênicos/metabolismo , Receptores Androgênicos/genética , Proteína Supressora de Tumor p53/metabolismo , Transcriptoma/efeitos da radiação , Transdução de Sinais/efeitos da radiação , Dano ao DNA/efeitos da radiação , Radioterapia com Íons Pesados , Reparo do DNA , Regulação Neoplásica da Expressão Gênica/efeitos da radiação , Regulação Neoplásica da Expressão Gênica/efeitos dos fármacos , Linhagem Celular Tumoral , Carbono/farmacologia
4.
Phys Med ; 123: 103427, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38959576

RESUMO

BACKGROUND: Reirradiation of head and neck cancer (HNC) became more accessible in the last decade, owing to modern irradiation techniques which offer a reduction in treatment related toxicities. The aim of this paper was to comparatively evaluate the dosimetric aspects derived from intensity modulated photon vs. proton treatment planning in reirradiated HNC patients. METHODS: Six recurrent HNC patients were enrolled in this retrospective study. For each patient two treatment plans were created: one IMRT/VMAT and one IMPT plan. The prescribed dose for the second irradiation was between 50 and 70 Gy RBE. The study comparatively analyzed the CTV coverage, doses to organs at risk (OARs) and low doses received by the healthy tissue (other than OAR). RESULTS: Similar CTV coverage was achieved for photon vs proton plans, with the latter presenting better homogeneity in four cases. Maximum dose to CTV was generally higher for photon plans, with differences ranging from 0.3 to 1.9%. For parotid glands and body, the mean dose was lower for proton plans. A notable reduction of low dose to healthy tissue (other than OARs) could be achieved with protons, with an average of 60% and 64% for D10% and Dmean, respectively. CONCLUSION: The dosimetric comparison between photon and proton reirradiation of HNC showed a great need for treatment individualization, concluding that protons should be considered for reirradiation on an individual basis.


Assuntos
Neoplasias de Cabeça e Pescoço , Órgãos em Risco , Fótons , Terapia com Prótons , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Reirradiação , Humanos , Neoplasias de Cabeça e Pescoço/radioterapia , Terapia com Prótons/métodos , Fótons/uso terapêutico , Radioterapia de Intensidade Modulada/métodos , Reirradiação/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco/efeitos da radiação , Estudos Retrospectivos
5.
Brain Nerve ; 76(7): 807-812, 2024 Jul.
Artigo em Japonês | MEDLINE | ID: mdl-38970316

RESUMO

Two-photon excitation microscopy enables in vivo deep-tissue imaging within organisms. This technique is based on two-photon excitation, a nonlinear optical process that uses near-infrared light for excitation, resulting in high tissue permeability. Notably, two-photon excitation occurs only near the focal plane; therefore, minimally invasive tomographic images can be obtained. Owing to these features, two-photon excitation microscopy is currently widely used in medical and life-science research, particularly in the domain of neuroscience for in vivo visualization of deep tissues. However, the use of long-wavelength excitation light in two-photon excitation microscopy has resulted in a larger focused spot size and relatively low spatial resolution, which is a limitation of this technique for further applications. Recent studies have described super-resolution microscopy techniques applied to two-photon excitation microscopy in an attempt to observe living organisms "as they are in their natural state" with high spatial resolution. We have also addressed this topic using an optical approach (two-photon stimulated emission depletion microscopy) and an image analysis approach (two-photon super-resolution radial fluctuation). Here, we describe these approaches together with a discussion of our recent accomplishments.


Assuntos
Microscopia de Fluorescência por Excitação Multifotônica , Animais , Humanos , Microscopia de Fluorescência por Excitação Multifotônica/métodos , Fótons , Microscopia/métodos , Processamento de Imagem Assistida por Computador/métodos
6.
Radiat Prot Dosimetry ; 200(11-12): 1167-1172, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39016473

RESUMO

There has been an increase in the use of high energy photon beam for container scanners in many countries for multi purposes such as detecting high atomic number materials which might be nuclear materials, drugs, high explosive materials and other contrabands etc. High energy photon beams generally 6 and 9 MV can be used for scanning such materials. However, it is important to ensure that radiation level beyond the container scanner installation is within the permissible dose limit specified by the national competent authority for the protection of public and radiation workers. In this paper, challenges in the biological shielding during the installation of high energy X-ray system for scanning vehicles containing suspected materials are discussed. The purpose of the present study is to develop a methodology for shielding design and evaluation for container scanner installations. The basic concept pertaining to shielding evaluation of radiotherapy installations provided in National Council on Radiation Protection and Measurements (NCRP)/International Atomic Energy Agency (IAEA) reports are referred, and appropriately used to calculate optimized shielding thicknesses requirements for container scanner installation. Workload is estimated based on number of containers scanned, machine ON time and dose rate at 1 m. The shielding evaluation includes use of beam stopper in the primary beam, scattering by heterogeneous metallic scrap materials or any other suspected materials contained in the vehicle and their impact on the thickness of shielding walls. A model lay out plan to be used for installation of container scanner is developed. A methodology for shielding evaluation for various protective walls and ceiling of this model is also discussed. The study provides basic requirement for designing a structural room for installing 9MV container scanner from radiological safety view point.


Assuntos
Desenho de Equipamento , Proteção Radiológica , Proteção Radiológica/instrumentação , Proteção Radiológica/normas , Humanos , Doses de Radiação , Fótons , Raios X
7.
Opt Lett ; 49(14): 4054-4057, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39008774

RESUMO

Two-photon autofluorescence (TPAF) imaging is able to offer precise cellular metabolic information with high spatiotemporal resolution, making it a promising biopsy tool. The technique is greatly hampered by the complexity of either the optical system or data processing. Here, the excitation wavelength was optimized to simultaneously excite both flavin adenine dinucleotide and nicotinamide adenine dinucleotide and eliminate the unexpected TPAF. The optical redox ratio (ORR) images were robustly achieved without additional calibration under the optimized single-wavelength excitation. The in vitro, ex vivo, and in vivo biopsy by the TPAF method were systematically studied and compared using hepato-cellular carcinoma and metastasis as examples. It was demonstrated that the proposed TPAF method simplified the optical system, improved the robustness of ORR, and enabled early-stage cancer diagnosis, showing distinguished advantages as compared with previous methods.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Imagem Óptica , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Imagem Óptica/métodos , Humanos , Animais , Metástase Neoplásica , Biópsia , Camundongos , NAD/metabolismo , Fótons , Flavina-Adenina Dinucleotídeo/metabolismo , Linhagem Celular Tumoral
8.
Magy Onkol ; 68(2): 163-168, 2024 Jul 16.
Artigo em Húngaro | MEDLINE | ID: mdl-39013090

RESUMO

We present evaluation of junction of coplanar external beam photon fields and its portal dosimetric analysis for breast cancer with positive lymph nodes. In our work, we compared twelve patients affected by breast cancer with axillary and supraclavicular lymph nodes, using conformal external beam plans from a dosimetric point of view. 3-3 plans were prepared per patient. Three methods were used for the conformal technique to investigate the potential of lymph nodes treatment field's collimations. During the evaluation of the portal dosimetry images, it was concluded that the junction plane at isocenter appeared as a discrete coldline, when fitted the regional field with or without collimation manually and by the software. However, the coverage of the isocenter plane is strongly influenced by the linear accelerator and the fitted field edges. Based on our results, in order to avoid uncertainties arising from field junctions and the overdosed areas of the target volume, it is more appropriate to choose another advanced irradiation technique such as intensity-modulated radiation therapy.


Assuntos
Axila , Neoplasias da Mama , Linfonodos , Metástase Linfática , Fótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Humanos , Feminino , Neoplasias da Mama/radioterapia , Neoplasias da Mama/patologia , Linfonodos/efeitos da radiação , Linfonodos/patologia , Fótons/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos , Metástase Linfática/radioterapia , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/métodos
9.
Radiol Cardiothorac Imaging ; 6(4): e230328, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39023373

RESUMO

Purpose To investigate the impact of plaque size and density on virtual noncontrast (VNC)-based coronary artery calcium scoring (CACS) using photon-counting detector CT and to provide safety net reconstructions for improved detection of subtle plaques in patients whose VNC-based CACS would otherwise be erroneously zero when compared with true noncontrast (TNC)-based CACS. Materials and Methods In this prospective study, CACS was evaluated in a phantom containing calcifications with different diameters (5, 3, and 1 mm) and densities (800, 400, and 200 mg/cm3) and in participants who underwent TNC and contrast-enhanced cardiac photon-counting detector CT (July 2021-March 2022). VNC images were reconstructed at different virtual monoenergetic imaging (55-80 keV) and quantum iterative reconstruction (QIR) levels (QIR,1-4). TNC scans at 70 keV with QIR off served as the reference standard. In vitro CACS was analyzed using standard settings (3.0-mm sections, kernel Qr36, 130-HU threshold). Calcification detectability and CACS of small and low-density plaques were also evaluated using 1.0-mm sections, kernel Qr44, and 120- or 110-HU thresholds. Safety net reconstructions were defined based on background Agatston scores and evaluated in vivo in TNC plaques initially nondetectable using standard VNC reconstructions. Results The in vivo cohort included 63 participants (57.8 years ± 15.5 [SD]; 37 [59%] male, 26 [41%] female). Correlation and agreement between standard CACSVNC and CACSTNC were higher in large- and medium-sized and high- and medium-density than in low-density plaques (in vitro: intraclass correlation coefficient [ICC] ≥ 0.90; r > 0.9 vs ICC = 0.20-0.48; r = 0.5-0.6). Small plaques were not detectable using standard VNC reconstructions. Calcification detectability was highest using 1.0-mm sections, kernel Qr44, 120- and 110-HU thresholds, and QIR level of 2 or less VNC reconstructions. Compared with standard VNC, using safety net reconstructions (55 keV, QIR 2, 110-HU threshold) for in vivo subtle plaque detection led to higher detection (increased by 89% [50 of 56]) and improved correlation and agreement of CACSVNC with CACSTNC (in vivo: ICC = 0.51-0.61; r = 0.6). Conclusion Compared with TNC-based calcium scoring, VNC-based calcium scoring was limited for small and low-density plaques but improved using safety net reconstructions, which may be particularly useful in patients with low calcium scores who would otherwise be treated based on potentially false-negative results. Keywords: Coronary Artery Calcium CT, Photon-Counting Detector CT, Virtual Noncontrast, Plaque Size, Plaque Density Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Doença da Artéria Coronariana , Imagens de Fantasmas , Placa Aterosclerótica , Humanos , Masculino , Feminino , Estudos Prospectivos , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Pessoa de Meia-Idade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Idoso , Fótons , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/patologia , Tomografia Computadorizada por Raios X/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Angiografia Coronária/métodos , Meios de Contraste
10.
J Biomed Opt ; 29(7): 076003, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38989529

RESUMO

Significance: Tissues' biomechanical properties, such as elasticity, are related to tissue health. Optical coherence elastography produces images of tissues based on their elasticity, but its performance is constrained by the laser power used, working distance, and excitation methods. Aim: We develop a new method to reconstruct the elasticity contrast image over a long working distance, with only low-intensity illumination, and by non-contact acoustic wave excitation. Approach: We combine single-photon vibrometry and quantum parametric mode sorting (QPMS) to measure the oscillating backscattered signals at a single-photon level and derive the phantoms' relative elasticity. Results: We test our system on tissue-mimicking phantoms consisting of contrast sections with different concentrations and thus stiffness. Our results show that as the driving acoustic frequency is swept, the phantoms' vibrational responses are mapped onto the photon-counting histograms from which their mechanical properties-including elasticity-can be derived. Through lateral and longitudinal laser scanning at a fixed frequency, a contrast image based on samples' elasticity can be reliably reconstructed upon photon level signals. Conclusions: We demonstrated the reliability of QPMS-based elasticity contrast imaging of agar phantoms in a long working distance, low-intensity environment. This technique has the potential for in-depth images of real biological tissue and provides a new approach to elastography research and applications.


Assuntos
Técnicas de Imagem por Elasticidade , Imagens de Fantasmas , Fótons , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Elasticidade , Reprodutibilidade dos Testes
11.
BMC Cancer ; 24(1): 837, 2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-39003464

RESUMO

BACKGROUND: This study aimed to compare the survival outcome and side effects in patients with primary high-grade glioma (HGG) who received carbon ion radiotherapy (CIRT) alone or as a boost strategy after photon radiation (photon + CIRTboost). PATIENTS AND METHODS: Thirty-four (34) patients with histologically confirmed HGG and received CIRT alone or Photon + CIRTboost, with concurrent temozolomide between 2020.03-2023.08 in Wuwei Cancer Hospital & Institute, China were retrospectively reviewed. Overall survival (OS), progression-free survival (PFS), and acute and late toxicities were analyzed and compared. RESULTS: Eight WHO grade 3 and 26 grade 4 patients were included in the analysis. The median PFS in the CIRT alone and Photon + CIRTboost groups were 15 and 19 months respectively for all HGG cases, and 15 and 17.5 months respectively for grade 4 cases. The median OS in the CIRT alone and Photon + CIRTboost groups were 28 and 31 months respectively for all HGG cases, and 21 and 19 months respectively for grade 4 cases. No significant difference in these survival outcomes was observed between the CIRT alone and Photon + CIRTboost groups. Only grade 1 acute toxicities were observed in CIRT alone and Photon + CIRTboost groups. CIRT alone group had a significantly lower ratio of acute toxicities compared to Photon + CIRTboost (3/18 vs. 9/16, p = 0.03). No significant difference in late toxicities was observed. CONCLUSION: Both CIRT alone and Photon + CIRTboost with concurrent temozolomide are safe, without significant differences in PFS and OS in HGG patients. It is meaningful to explore whether dose escalation of CIRTboost might improve survival outcomes of HGG patients in future randomized trials.


Assuntos
Glioma , Radioterapia com Íons Pesados , Fótons , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Radioterapia com Íons Pesados/efeitos adversos , Radioterapia com Íons Pesados/métodos , Feminino , Masculino , Glioma/radioterapia , Glioma/mortalidade , Glioma/patologia , Fótons/uso terapêutico , Fótons/efeitos adversos , Adulto , Idoso , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/mortalidade , Temozolomida/uso terapêutico , Gradação de Tumores , Adulto Jovem , Intervalo Livre de Progressão , Resultado do Tratamento
12.
Biomed Phys Eng Express ; 10(5)2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-38968931

RESUMO

Quantitative contrast-enhanced breast computed tomography (CT) has the potential to improve the diagnosis and management of breast cancer. Traditional CT methods using energy-integrated detectors and dual-exposure images with different incident spectra for material discrimination can increase patient radiation dose and be susceptible to motion artifacts and spectral resolution loss. Photon Counting Detectors (PCDs) offer a promising alternative approach, enabling acquisition of multiple energy levels in a single exposure and potentially better energy resolution. Gallium arsenide (GaAs) is particularly promising for breast PCD-CT due to its high quantum efficiency and reduction of fluorescence x-rays escaping the pixel within the breast imaging energy range. In this study, the spectral performance of a GaAs PCD for quantitative iodine contrast-enhanced breast CT was evaluated. A GaAs detector with a pixel size of 100µm, a thickness of 500µm was simulated. Simulations were performed using cylindrical phantoms of varying diameters (10 cm, 12 cm, and 16 cm) with different concentrations and locations of iodine inserts, using incident spectra of 50, 55, and 60 kVp with 2 mm of added aluminum filtration and and a mean glandular dose of 10 mGy. We accounted for the effects of beam hardening and energy detector response using TIGRE CT open-source software and the publicly available Photon Counting Toolkit (PcTK). Material-specific images of the breast phantom were produced using both projection and image-based material decomposition methods, and iodine component images were used to estimate iodine intake. Accuracy and precision of the proposed methods for estimating iodine concentration in breast CT images were assessed for different material decomposition methods, incident spectra, and breast phantom thicknesses. The results showed that both the beam hardening effect and imperfection in the detector response had a significant impact on performance in terms of Root Mean Squared Error (RMSE), precision, and accuracy of estimating iodine intake in the breast. Furthermore, the study demonstrated the effectiveness of both material decomposition methods in making accurate and precise iodine concentration predictions using a GaAs-based photon counting breast CT system, with better performance when applying the projection-based material decomposition approach. The study highlights the potential of GaAs-based photon counting breast CT systems as viable alternatives to traditional imaging methods in terms of material decomposition and iodine concentration estimation, and proposes phantoms and figures of merit to assess their performance.


Assuntos
Arsenicais , Neoplasias da Mama , Mama , Meios de Contraste , Gálio , Iodo , Mamografia , Imagens de Fantasmas , Fótons , Tomografia Computadorizada por Raios X , Gálio/química , Humanos , Feminino , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste/química , Mamografia/métodos , Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Simulação por Computador , Método de Monte Carlo , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação
14.
Int J Biol Macromol ; 273(Pt 2): 132706, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38825294

RESUMO

Benzene, as a common volatile organic compound, represents serious risk to human health and environment even at low level concentration. There is an urgent concern on visualized, sensitive and real time detection of benzene gases. Herein, by doping Fe3+ and graphene quantum dots (GQDs), a cellulose nanocrystal (CNC) chiral nematic film was designed with dual response of photonic colors and fluorescence to benzene gas. The chiral nematic CNC/Fe/GQDs film could respond to benzene gas changes by reversible motion. Moreover, chiral nematic film also displays reversible responsive to humidity changes. The resulting CNC/Fe/GQDs chiral nematic film showed excellent response performance at benzene gas concentrations of 0-250 mg/m3. The maximal reflection wavelength film red shifted from 576 to 625 nm. Furthermore, structural color of CNC/Fe/GQDs chiral nematic film change at 44 %, 54 %, 76 %, 87 %, and 99 % relative humidity. Interestingly, due to the stability of GQDs to water molecules, CNC/Fe/GQDs chiral nematic film exhibit fluorescence response to benzene gas even in high humidity (RH = 99 %) environment. Besides, we further developed a smartphone-based response network system for quantitively determinization and signal transformation. This work provides a promising routine to realize a new benzene gas response regime and promotes the development of real-time benzene gas detection.


Assuntos
Benzeno , Celulose , Nanopartículas , Celulose/química , Benzeno/química , Benzeno/análise , Nanopartículas/química , Pontos Quânticos/química , Grafite/química , Fluorescência , Gases/análise , Gases/química , Cor , Fótons
15.
Molecules ; 29(12)2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38930882

RESUMO

The abnormal deposition of protein in the brain is the central factor in neurodegenerative disorders (NDs). These detrimental aggregates, stemming from the misfolding and subsequent irregular aggregation of α-synuclein protein, are primarily accountable for conditions such as Parkinson's disease, Alzheimer's disease, and dementia. Two-photon-excited (TPE) probes are a promising tool for the early-stage diagnosis of these pathologies as they provide accurate spatial resolution, minimal intrusion, and the ability for prolonged observation. To identify compounds with the potential to function as diagnostic probes using two-photon techniques, we explore three distinct categories of compounds: Hydroxyl azobenzene (AZO-OH); Dicyano-vinyl bithiophene (DCVBT); and Tetra-amino phthalocyanine (PcZnNH2). The molecules were structurally and optically characterized using a multi-technique approach via UV-vis absorption, Raman spectroscopy, three-dimensional fluorescence mapping (PLE), time-resolved photoluminescence (TRPL), and pump and probe measurements. Furthermore, quantum chemical and molecular docking calculations were performed to provide insights into the photophysical properties of the compounds as well as to assess their affinity with the α-synuclein protein. This innovative approach seeks to enhance the accuracy of in vivo probing, contributing to early Parkinson's disease (PD) detection and ultimately allowing for targeted intervention strategies.


Assuntos
Simulação de Acoplamento Molecular , Fótons , alfa-Sinucleína , alfa-Sinucleína/química , Humanos , Agregados Proteicos , Compostos Azo/química , Corantes Fluorescentes/química , Análise Espectral Raman/métodos , Doença de Parkinson/diagnóstico , Doença de Parkinson/metabolismo , Tiofenos/química , Indóis/química , Estrutura Molecular
16.
Igaku Butsuri ; 44(2): 29-35, 2024.
Artigo em Japonês | MEDLINE | ID: mdl-38945880

RESUMO

This is an explanatory paper on Sun Il Kwon et al., Nat. Photon. 15: 914-918, 2021 and some parts of this manuscript are translated from the paper. Medical imaging modalities such as X-ray computed tomography, Magnetic resonance imaging, positron emission tomography (PET), and single photon emission computed tomography, require image reconstruction processes, consequently constraining them to form cylindrical shapes. However, among them, only PET can use additional information, so called time of flight, on an event-by-event basis. If coincidence time resolution (CTR) of PET detectors improved to 30 ps, which corresponds to spatial resolution of 4.5 mm, directly localizing electron-positron annihilation point is possible, allowing us to circumvent image reconstruction processes and free us from the geometric constraint. We call this concept direct positron emission imaging (dPEI). We have developed ultrafast radiation detectors by focusing on Cherenkov photon detection. Furthermore, the CTR of 32 ps being equivalent to 4.8 mm spatial resolution is achieved by combining deep learning-based signal processing with the detectors. In this article, we explain how we developed the detectors and demonstrated the first dPEI using different types of phantoms, how we will tackle limitations to be addressed to make the dPEI more practical, and how dPEI will emerge as an imaging modality in nuclear medicine.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Fótons , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/métodos , Fatores de Tempo
17.
Korean J Radiol ; 25(7): 662-672, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38942460

RESUMO

Since the emergence of the first photon-counting computed tomography (PCCT) system in late 2021, its advantages and a wide range of applications in all fields of radiology have been demonstrated. Compared to standard energy-integrating detector-CT, PCCT allows for superior geometric dose efficiency in every examination. While this aspect by itself is groundbreaking, the advantages do not stop there. PCCT facilitates an unprecedented combination of ultra-high-resolution imaging without dose penalty or field-of-view restrictions, detector-based elimination of electronic noise, and ubiquitous multi-energy spectral information. Considering the high demands of orthopedic imaging for the visualization of minuscule details while simultaneously covering large portions of skeletal and soft tissue anatomy, no subspecialty may benefit more from this novel detector technology than musculoskeletal radiology. Deeply rooted in experimental and clinical research, this review article aims to provide an introduction to the cosmos of PCCT, explain its technical basics, and highlight the most promising applications for patient care, while also mentioning current limitations that need to be overcome.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Doenças Musculoesqueléticas/diagnóstico por imagem , Sistema Musculoesquelético/diagnóstico por imagem , Doses de Radiação
18.
Phys Med Biol ; 69(14)2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38942008

RESUMO

Objective.Proton therapy is a limited resource and is typically not available to metastatic cancer patients. Combined proton-photon therapy (CPPT), where most fractions are delivered with photons and only few with protons, represents an approach to distribute proton resources over a larger patient population. In this study, we consider stereotactic radiotherapy of multiple brain or liver metastases, and develop an approach to optimally take advantage of a single proton fraction by optimizing the proton and photon dose contributions to each individual metastasis.Approach.CPPT treatments must balance two competing goals: (1) deliver a larger dose in the proton fractions to reduce integral dose, and (2) fractionate the dose in the normal tissue between metastases, which requires using the photon fractions. Such CPPT treatments are generated by simultaneously optimizing intensity modulated proton therapy (IMPT) and intensity modulated radiotherapy (IMRT) plans based on their cumulative biologically effective dose (BEDα/ß). The dose contributions of the proton and photon fractions to each individual metastasis are handled as additional optimization variables in the optimization problem. The method is demonstrated for two patients with 29 and 30 brain metastases, and two patients with 4 and 3 liver metastases.Main results.Optimized CPPT plans increase the proton dose contribution to most of the metastases, while using photons to fractionate the dose around metastases which are large or located close to critical structures. On average, the optimized CPPT plans reduce the mean brain BED2by 29% and the mean liver BED4by 42% compared to IMRT-only plans. Thereby, the CPPT plans approach the dosimetric quality of IMPT-only plans, for which the mean brain BED2and mean liver BED4are reduced by 28% and 58%, respectively, compared to IMRT-only plans.Significance.CPPT with optimized proton and photon dose contributions to individual metastases may benefit selected metastatic cancer patients without tying up major proton resources.


Assuntos
Neoplasias Encefálicas , Neoplasias Hepáticas , Fótons , Terapia com Prótons , Humanos , Terapia com Prótons/métodos , Fótons/uso terapêutico , Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/radioterapia , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Metástase Neoplásica/radioterapia , Dosagem Radioterapêutica
19.
Biosensors (Basel) ; 14(6)2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38920610

RESUMO

Current quantitative gene expression detection in genomic and transcriptomic research heavily relies on quantitative real-time PCR (qPCR). While existing multiplex gene detection techniques offer simultaneous analysis of multiple targets, we present an alternative assay capable of detecting gene expression simultaneously within a single well. This highly sensitive method utilizes πCode MicroDiscs, featuring unique identification patterns and fluorescent detection. Our study compared this multiplex πCode platform with a qPCR platform for profiling cytokine gene expression. The πCode MicroDisc assay successfully demonstrated the expression of polymerization markers for M1- and M2-like macrophages generated from THP-1-derived macrophages in a qualitative assay. Additionally, our findings suggest a pattern agreement between the πCode assay and the qPCR assay, indicating the potential of the πCode technology for comparative gene expression analysis. Regarding the inherent sensitivity and linearity, the developed πCode assay primarily provides qualitative gene expression to discriminate the polarization of macrophages. This remarkable capability presents substantial advantages for researchers, rendering the technology highly suitable for high-throughput applications in clinical diagnosis and disease monitoring.


Assuntos
Citocinas , Macrófagos , Humanos , Citocinas/metabolismo , Técnicas Biossensoriais , Fótons , Perfilação da Expressão Gênica , Expressão Gênica , Reação em Cadeia da Polimerase em Tempo Real
20.
Phys Med ; 123: 103396, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38943799

RESUMO

PURPOSE: Respiratory motion and patient setup error both contribute to the dosimetric uncertainty in radiotherapy of lung tumors. Managing these uncertainties for free-breathing treatments is usually done by margin-based approaches or robust optimization. However, breathing motion can be irregular and concerns have been raised for the robustness of the treatment plans. We have previously reported the dosimetric effects of the respiratory motion, without setup uncertainties, in lung tumor photon radiotherapy using free-breathing images. In this study, we include setup uncertainty. METHODS: Tumor positions from cine-CT images acquired in free-breathing were combined with per-fraction patient shifts to simulate treatment scenarios. A total of 14 patients with 300 tumor positions were used to evaluate treatment plans based on 4DCT. Four planning methods aiming at delivering 54 Gy as median tumor dose in three fractions were compared. The planning methods were denoted robust 4D (RB4), isodose to the PTV with a central higher dose (ISD), the ISD method normalized to the intended median tumor dose (IRN) and homogeneous fluence to the PTV (FLU). RESULTS: For all planning methods 95% of the intended dose was achieved with at least 90% probability with RB4 and FLU having equal CTV D50% values at this probability. FLU gave the most consistent results in terms of CTV D50% spread and dose homogeneity. CONCLUSIONS: Despite the simulated patient shifts and tumor motions being larger than observed in the 4DCTs the dosimetric impact was suggested to be small. RB4 or FLU are recommended for the planning of free-breathing treatments.


Assuntos
Tomografia Computadorizada Quadridimensional , Neoplasias Pulmonares , Fótons , Planejamento da Radioterapia Assistida por Computador , Respiração , Humanos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagem , Incerteza , Planejamento da Radioterapia Assistida por Computador/métodos , Fótons/uso terapêutico , Movimento , Dosagem Radioterapêutica , Erros de Configuração em Radioterapia/prevenção & controle , Radiometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...