Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74.977
Filtrar
1.
J Am Coll Radiol ; 21(6S): S237-S248, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38823947

RESUMO

This document summarizes the relevant literature for the selection of preprocedural imaging in three clinical scenarios in patients needing endovascular treatment or cardioversion of atrial fibrillation. These clinical scenarios include preprocedural imaging prior to radiofrequency ablation; prior to left atrial appendage occlusion; and prior to cardioversion. The appropriateness of imaging modalities as they apply to each clinical scenario is rated as usually appropriate, may be appropriate, and usually not appropriate to assist the selection of the most appropriate imaging modality in the corresponding clinical scenarios. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Assuntos
Fibrilação Atrial , Medicina Baseada em Evidências , Sociedades Médicas , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Humanos , Estados Unidos , Cuidados Pré-Operatórios/métodos , Cardioversão Elétrica/métodos , Átrios do Coração/diagnóstico por imagem , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia
2.
Int Heart J ; 65(3): 404-413, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38825490

RESUMO

This study aimed to clarify (1) the association among the atrial fibrillation (AF) type, sleep-disordered breathing (SDB), heart failure (HF), and left atrial (LA) enlargement, (2) the independent predictors of LA enlargement, and (3) the effects of ablation on those conditions in patients with AF. The study's endpoint was LA enlargement (LA volume index [LAVI] ≥ 78 mL/m2).Of 423 patients with nonvalvular AF, 236 were enrolled. We evaluated the role of the clinical parameters such as the AF type, SDB severity, and HF in LA enlargement. Among them, 141 patients exhibiting a 3% oxygen desaturation index (ODI) of ≥ 10 events/hour underwent polysomnography to evaluate the SDB severity measured by the apnea-hypopnea index (AHI). The LA enlargement and HF were characterized by the LA diameter/LAVI, an increase in the B-type natriuretic peptide level, and a lower left ventricular ejection fraction.This study showed that non-paroxysmal AF (NPAF) rather than paroxysmal AF (PAF), the SDB severity, LA enlargement, and HF progression had bidirectional associations and exacerbated each other, which generated a vicious cycle that contributed to the LA enlargement. NPAF (OR = 4.55, P < 0.001), an AHI of ≥ 25.10 events/hour (OR = 1.55, P = 0.003), and a 3% ODI of ≥ 15.43 events/hour (OR = 1.52, P = 0.003) were independent predictors of an acceleration of the LA enlargement. AF ablation improved the HF and LA enlargement.To break this vicious cycle, AF ablation may be the basis for suppressing the LA enlargement and HF progression subsequently eliminating the substrates for AF and SDB in patients with AF.


Assuntos
Fibrilação Atrial , Progressão da Doença , Átrios do Coração , Insuficiência Cardíaca , Índice de Gravidade de Doença , Síndromes da Apneia do Sono , Humanos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/complicações , Masculino , Feminino , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/fisiopatologia , Síndromes da Apneia do Sono/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/complicações , Pessoa de Meia-Idade , Idoso , Átrios do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Ablação por Cateter/métodos , Polissonografia , Remodelamento Atrial/fisiologia , Ecocardiografia
5.
Echocardiography ; 41(6): e15852, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38837738

RESUMO

PURPOSE: To assess left atrial (LA) function in individuals with known paroxysmal atrial fibrillation (AF) compared with healthy and nonhealthy individuals without atrial fibrillation. METHODS: The Akershus Cardiac Examination 1950 Study included 3,706 individuals all born in 1950. LA strain assessment of reservoir (LASr), conduit (LAScd) and contractile (LASct) functions were performed in all participants by investigators blinded to clinical data. Participants with cardiovascular disease, obesity, diabetes, pulmonary or renal disease were defined as nonhealthy, and those without as healthy. Patients with paroxysmal AF were identified through medical history and ECG documentation. RESULTS: LA strain assessment was feasible in 3,229 (87%) of the participants (50% women). The healthy group (n = 758) had significantly higher LASr and LAScd than the nonhealthy (n = 2,376), but LASct was similar between the groups. Participants with paroxysmal AF had significantly lower values of all strain parameters than the other groups. Multivariable logistic regression showed a significantly reduced probability of having AF per standard deviation increase in LASr and LASct. A nonlinear restricted cubic spline model fitted better with the association of LASr with paroxysmal AF than the linear model, and LA strain values below the population mean associated with an increased probability of having AF, but for values above the population mean no such association was present. CONCLUSION: Compared to participants without AF, those with known paroxysmal AF had significantly lower values of all LA strain parameters during sinus rhythm. Lower values of LA strain were associated with a significantly increased probability of having AF.


Assuntos
Fibrilação Atrial , Átrios do Coração , Humanos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Feminino , Masculino , Pessoa de Meia-Idade , Átrios do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Função do Átrio Esquerdo/fisiologia , Ecocardiografia/métodos
7.
JACC Heart Fail ; 12(6): 990-998, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38839160

RESUMO

Because of the bidirectional relationship between atrial fibrillation (AF) and heart failure with preserved ejection fraction (HFpEF), individuals with either condition require consideration of screening for the other. In this review, we summarize current evidence and rationale for screening for occult HFpEF in adults with clinical AF; and occult AF in patients with clinically recognized HFpEF. Assessment of pretest probability for occult HFpEF in symptomatic AF patients may help guide additional testing such as exercise right heart catheterization to diagnose HFpEF and guide HFpEF-specific therapies. In patients with HFpEF, AF screening will identify cases of occult AF where anticoagulation may decrease stroke risk, and correlation of previously unknown AF episodes with paroxysmal symptoms may prompt consideration for rhythm control. Therefore, screening may help clinicians understand the etiology of the often-overlapping symptoms, and it may help guide treatments to slow progression of both conditions and their complications.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Volume Sistólico , Humanos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/complicações , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/complicações , Volume Sistólico/fisiologia , Programas de Rastreamento/métodos
10.
EuroIntervention ; 20(11): e718-e727, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38840576

RESUMO

BACKGROUND: Left atrial appendage occlusion (LAAO) is performed increasingly, but long-term follow-up imaging data are lacking. AIMS: The aim of this study was to evaluate the safety and durability of the Amplatzer Amulet device >4 years after LAAO. METHODS: This was a prospective observational cohort study including 52 patients implanted with the Amplatzer Amulet device at Aarhus University Hospital, Denmark. A >4-year follow-up cardiac computed tomography (CT) scan after LAAO was performed and compared with the results from the 2-month and 12-month scans. The primary outcome was left atrial appendage (LAA) sealing based on distal LAA contrast patency and peridevice leakage (PDL), stratified into complete occlusion (grade 0 [G0]) and grade 1-3 leakage (G1-3), respectively. Secondary outcomes were low- and high-grade hypoattenuated thickening (HAT), device-related thrombosis (DRT) and device durability. RESULTS: The median (interquartile range [IQR]) follow-up time from LAAO to the latest CT scan was 5.8 years (4.5; 6.3). At 2-month (n=52), 12-month (n=27) and >4-year CT follow-ups (n=52), rates of both complete occlusion (33%, 37%, 35%) and G2 leaks (52%, 52%, 48%) remained stable. Rates of G1 leaks varied (14%, 4%, 6%) and G3 leaks rose (2%, 7%, 12%) from earliest to latest follow-up. The median left atrial (LA) volume increased from 127 mL (96; 176) to 144 mL (108; 182) and 147 mL (107; 193). No DRT was found. The structural device integrity was preserved. CONCLUSIONS: This study indicates a stable LAA sealing status throughout the follow-up period, emphasising the importance of the procedural result in avoiding PDL. Few patients displayed PDL progression, which might partly be related to LA remodelling with increasing volume. The long-term device durability appears excellent. Larger studies are warranted to confirm these findings.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Tomografia Computadorizada por Raios X , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Apêndice Atrial/fisiopatologia , Masculino , Feminino , Idoso , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Estudos Prospectivos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Seguimentos , Pessoa de Meia-Idade , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação
12.
BMC Cardiovasc Disord ; 24(1): 293, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844866

RESUMO

Patients with previous interatrial shunt device (IASD) implantation may face greater challenges during future left atrial interventional procedures. Herein, we report the first case of left atrial appendage closure (LAAC) in a patient with previous IASD implantation. The patient successfully underwent LAAC using the LAmbre device without complications.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Humanos , Apêndice Atrial/fisiopatologia , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/instrumentação , Masculino , Feminino , Ecocardiografia Transesofagiana , Idoso , Função do Átrio Esquerdo , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/terapia , Forame Oval Patente/complicações , Forame Oval Patente/fisiopatologia , Forame Oval Patente/cirurgia , Oclusão do Apêndice Atrial Esquerdo
13.
J Cardiothorac Surg ; 19(1): 315, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38824517

RESUMO

BACKGROUND: Post-operative atrial fibrillation (POAF) occurs in up to 40% of patients following coronary artery bypass grafting (CABG) and is associated with a higher risk of stroke and mortality. This study investigates how POAF may be mitigated by epicardial placement of aseptically processed human placental membrane allografts (HPMAs) before pericardial closure in CABG surgery. This study was conducted as a pilot feasibility study to collect preliminary for a forthcoming multi-center randomized controlled trial. METHODS: This retrospective observational study of patients undergoing CABG surgery excluded patients with pre-operative heart failure, chronic kidney disease, or a history of atrial fibrillation. The "treatment" group (n = 24) had three HPMAs placed epicardially following cardiopulmonary bypass decannulation but before partial pericardial approximation and chest closure. The only difference in clinical protocol for the control group (n = 54) was that they did not receive HPMA. RESULTS: HPMA-treated patients saw a significant, greater than four-fold reduction in POAF incidence compared to controls (35.2-8.3%, p = 0.0136). Univariate analysis demonstrated that HPMA treatment was associated with an 83% reduction in POAF (OR = 0.17, p = 0.0248). Multivariable analysis yielded similar results (OR = 0.07, p = 0.0156) after controlling for other covariates. Overall length of stay (LOS) between groups was similar, but ICU LOS trended lower with HPMA treatment (p = 0.0677). Post-operative inotrope and vasopressor requirements were similar among groups. There was no new-onset post-operative heart failure, stroke, or death reported up to thirty days in either group. CONCLUSIONS: Epicardial HPMA placement can be a simple intervention at the end of CABG surgery that may provide a new approach to reduce post-operative atrial fibrillation by modulating local inflammation, possibly reducing ICU and hospital stay, and ultimately improving patient outcomes.


Assuntos
Fibrilação Atrial , Ponte de Artéria Coronária , Placenta , Complicações Pós-Operatórias , Humanos , Fibrilação Atrial/prevenção & controle , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Ponte de Artéria Coronária/métodos , Ponte de Artéria Coronária/efeitos adversos , Feminino , Projetos Piloto , Masculino , Estudos Retrospectivos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Idoso , Gravidez , Aloenxertos , Pericárdio , Estudos de Viabilidade
14.
Turk Kardiyol Dern Ars ; 52(4): 237-243, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38829634

RESUMO

OBJECTIVE: This study aims to explore the impact of sodium-glucose cotransporter-2 (SGLT-2) inhibitors, a newer class of oral antidiabetic drugs, on atrial electromechanical delay (EMD) in patients with type 2 diabetes mellitus (DM). This is particularly relevant given the significantly higher incidence of atrial fibrillation (AF) in diabetic patients compared to the general population. Atrial electromechanical delay is recognized as an important factor influencing the development of atrial fibrillation. METHODS: This study included 30 type 2 DM patients (53.3% female, mean age 60.07 ± 10.03 years), initiating treatment with SGLT-2 inhibitors. The patients were assessed using echocardiography at baseline and again at 6 months, focusing on basic echocardiographic parameters and atrial electromechanical delay times (EMD) measured via tissue Doppler imaging. RESULTS: No significant changes were observed in intra-atrial EMD times. However, significant reductions were noted in interatrial EMD times, decreasing from 15.13 ± 5.87 ms to 13.20 ± 6.12 ms (P = 0.029). Statistically significant shortening occurred in lateral pulmonary acceleration (PA) times (from 58.73 ± 6.41 ms to 54.37 ± 6.97 ms, P < 0.001), septal PA times (from 50.90 ± 6.02 ms to 48.23 ± 5), and tricuspid PA times (from 43.60 ± 6.28 ms to 41.30 ± 5.60 ms, P = 0.003). Additionally, there was a significant reduction in the E/e' ratio from 8.13 ± 4.0 to 6.50 ± 2.37 (P = 0.003). CONCLUSION: SGLT-2 inhibitors might positively influence atrial electromechanical conduction, reducing DM-related functional impairments and the risk of arrhythmias, particularly AF.


Assuntos
Fibrilação Atrial , Diabetes Mellitus Tipo 2 , Inibidores do Transportador 2 de Sódio-Glicose , Humanos , Feminino , Inibidores do Transportador 2 de Sódio-Glicose/uso terapêutico , Inibidores do Transportador 2 de Sódio-Glicose/farmacologia , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/complicações , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/efeitos dos fármacos , Átrios do Coração/fisiopatologia , Idoso , Sistema de Condução Cardíaco/efeitos dos fármacos , Sistema de Condução Cardíaco/fisiopatologia , Ecocardiografia
16.
Cochrane Database Syst Rev ; 6: CD013255, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38828867

RESUMO

BACKGROUND: Atrial fibrillation (AF) is the most frequent sustained arrhythmia. Cardioversion is a rhythm control strategy to restore normal/sinus rhythm, and can be achieved through drugs (pharmacological) or a synchronised electric shock (electrical cardioversion). OBJECTIVES: To assess the efficacy and safety of pharmacological and electrical cardioversion for atrial fibrillation (AF), atrial flutter and atrial tachycardias. SEARCH METHODS: We searched CENTRAL, MEDLINE, Embase, Conference Proceedings Citation Index-Science (CPCI-S) and three trials registers (ClinicalTrials.gov, WHO ICTRP and ISRCTN) on 14 February 2023. SELECTION CRITERIA: We included randomised controlled trials (RCTs) at the individual patient level. Patient populations were aged ≥ 18 years with AF of any type and duration, atrial flutter or other sustained related atrial arrhythmias, not occurring as a result of reversible causes. DATA COLLECTION AND ANALYSIS: We used standard Cochrane methodology to collect data and performed a network meta-analysis using the standard frequentist graph-theoretical approach using the netmeta package in R. We used GRADE to assess the quality of the evidence which we presented in our summary of findings with a judgement on certainty. We calculated differences using risk ratios (RR) and 95% confidence intervals (CI) as well as ranking treatments using a P value. We assessed clinical and statistical heterogeneity and split the networks for the primary outcome and acute procedural success, due to concerns about violating the transitivity assumption. MAIN RESULTS: We included 112 RCTs (139 records), from which we pooled data from 15,968 patients. The average age ranged from 47 to 72 years and the proportion of male patients ranged from 38% to 92%. Seventy-nine trials were considered to be at high risk of bias for at least one domain, 32 had no high risk of bias domains, but had at least one domain classified as uncertain risk, and one study was considered at low risk for all domains. For paroxysmal AF (35 trials), when compared to placebo, anteroapical (AA)/anteroposterior (AP) biphasic truncated exponential waveform (BTE) cardioversion (RR: 2.42; 95% CI 1.65 to 3.56), quinidine (RR: 2.23; 95% CI 1.49 to 3.34), ibutilide (RR: 2.00; 95% CI 1.28 to 3.12), propafenone (RR: 1.98; 95% CI 1.67 to 2.34), amiodarone (RR: 1.69; 95% CI 1.42 to 2.02), sotalol (RR: 1.58; 95% CI 1.08 to 2.31) and procainamide (RR: 1.49; 95% CI 1.13 to 1.97) likely result in a large increase in maintenance of sinus rhythm until hospital discharge or end of study follow-up (certainty of evidence: moderate). The effect size was larger for AA/AP incremental and was progressively smaller for the subsequent interventions. Despite low certainty of evidence, antazoline may result in a large increase (RR: 28.60; 95% CI 1.77 to 461.30) in this outcome. Similarly, low-certainty evidence suggests a large increase in this outcome for flecainide (RR: 2.17; 95% CI 1.68 to 2.79), vernakalant (RR: 2.13; 95% CI 1.52 to 2.99), and magnesium (RR: 1.73; 95% CI 0.79 to 3.79). For persistent AF (26 trials), one network was created for electrical cardioversion and showed that, when compared to AP BTE incremental energy with patches, AP BTE maximum energy with patches (RR 1.35, 95% CI 1.17 to 1.55) likely results in a large increase, and active compression AP BTE incremental energy with patches (RR: 1.14, 95% CI 1.00 to 1.131) likely results in an increase in maintenance of sinus rhythm at hospital discharge or end of study follow-up (certainty of evidence: high). Use of AP BTE incremental with paddles (RR: 1.03, 95% CI 0.98 to 1.09; certainty of evidence: low) may lead to a slight increase, and AP MDS Incremental paddles (RR: 0.95, 95% CI 0.86 to 1.05; certainty of evidence: low) may lead to a slight decrease in efficacy. On the other hand, AP MDS incremental energy using patches (RR: 0.78, 95% CI 0.70 to 0.87), AA RBW incremental energy with patches (RR: 0.76, 95% CI 0.66 to 0.88), AP RBW incremental energy with patches (RR: 0.76, 95% CI 0.68 to 0.86), AA MDS incremental energy with patches (RR: 0.76, 95% CI 0.67 to 0.86) and AA MDS incremental energy with paddles (RR: 0.68, 95% CI 0.53 to 0.83) probably result in a decrease in this outcome when compared to AP BTE incremental energy with patches (certainty of evidence: moderate). The network for pharmacological cardioversion showed that bepridil (RR: 2.29, 95% CI 1.26 to 4.17) and quindine (RR: 1.53, (95% CI 1.01 to 2.32) probably result in a large increase in maintenance of sinus rhythm at hospital discharge or end of study follow-up when compared to amiodarone (certainty of evidence: moderate). Dofetilide (RR: 0.79, 95% CI 0.56 to 1.44), sotalol (RR: 0.89, 95% CI 0.67 to 1.18), propafenone (RR: 0.79, 95% CI 0.50 to 1.25) and pilsicainide (RR: 0.39, 95% CI 0.02 to 7.01) may result in a reduction in this outcome when compared to amiodarone, but the certainty of evidence is low. For atrial flutter (14 trials), a network could be created only for antiarrhythmic drugs. Using placebo as the common comparator, ibutilide (RR: 21.45, 95% CI 4.41 to 104.37), propafenone (RR: 7.15, 95% CI 1.27 to 40.10), dofetilide (RR: 6.43, 95% CI 1.38 to 29.91), and sotalol (RR: 6.39, 95% CI 1.03 to 39.78) probably result in a large increase in the maintenance of sinus rhythm at hospital discharge or end of study follow-up (certainty of evidence: moderate), and procainamide (RR: 4.29, 95% CI 0.63 to 29.03), flecainide (RR 3.57, 95% CI 0.24 to 52.30) and vernakalant (RR: 1.18, 95% CI 0.05 to 27.37) may result in a large increase in maintenance of sinus rhythm at hospital discharge or end of study follow-up (certainty of evidence: low). All tested electrical cardioversion strategies for atrial flutter had very high efficacy (97.9% to 100%). The rate of mortality (14 deaths) and stroke or systemic embolism (3 events) at 30 days was extremely low. Data on quality of life were scarce and of uncertain clinical significance. No information was available regarding heart failure readmissions. Data on duration of hospitalisation was scarce, of low quality, and could not be pooled. AUTHORS' CONCLUSIONS: Despite the low quality of evidence, this systematic review provides important information on electrical and pharmacological strategies to help patients and physicians deal with AF and atrial flutter. In the assessment of the patient comorbidity profile, antiarrhythmic drug onset of action and side effect profile versus the need for a physician with experience in sedation, or anaesthetics support for electrical cardioversion are key aspects when choosing the cardioversion method.


Assuntos
Antiarrítmicos , Fibrilação Atrial , Flutter Atrial , Cardioversão Elétrica , Metanálise em Rede , Ensaios Clínicos Controlados Aleatórios como Assunto , Idoso , Humanos , Pessoa de Meia-Idade , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Fibrilação Atrial/tratamento farmacológico , Flutter Atrial/terapia , Viés , Taquicardia/terapia , Masculino , Feminino
17.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38829189

RESUMO

AIMS: Elective cardioversion (ECV) is routinely used in atrial fibrillation (AF) to restore sinus rhythm. However, it includes a risk of thromboembolism even during adequate oral anticoagulation treatment. The aim of this study was to evaluate the risk of thromboembolic and bleeding complications after ECV in a real-life setting utilizing data from a large AF population. METHODS AND RESULTS: This nationwide register-based study included all (n = 9625) Finnish AF patients undergoing their first-ever ECV between 2012 and 2018. The thromboembolic and bleeding complications within 30 days after ECV were analysed. The mean age of the patients was 67.7 ± 9.9 years, 61.2% were men, and the mean CHA2DS2-VASc score was 2.6 ± 1.6. Warfarin was used in 6245 (64.9%) and non-vitamin K oral anticoagulants (NOACs) in 3380 (35.1%) cardioversions. Fifty-two (0.5%) thromboembolic complications occurred, of which 62% were ischaemic strokes, 25% transient ischaemic attacks, and 13% other systemic embolisms. Thromboembolic events occurred in 14 (0.4%) NOAC-treated patients and in 38 (0.6%) warfarin-treated patients (odds ratio 0.77; confidence interval: 0.42-1.39). The median time from ECV to the thromboembolic event was 2 days, and 78% of the events occurred within 10 days. Age and alcohol abuse were significant predictors of thromboembolic events. Among warfarin users, thromboembolic complications were more common with international normalized ratio (INR) <2.5 than INR ≥2.5 (0.9% vs. 0.4%, P = 0.026). Overall, 27 (0.3%) bleeding events occurred. CONCLUSION: The rate of thromboembolic and bleeding complications related to ECV was low without significant difference between NOAC- and warfarin-treated patients. With warfarin, INR ≥2.5 at the time of cardioversion reduced the risk of thromboembolic complications.


Assuntos
Anticoagulantes , Fibrilação Atrial , Cardioversão Elétrica , Hemorragia , Sistema de Registros , Tromboembolia , Humanos , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/tratamento farmacológico , Masculino , Cardioversão Elétrica/efeitos adversos , Feminino , Idoso , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Tromboembolia/epidemiologia , Anticoagulantes/uso terapêutico , Anticoagulantes/efeitos adversos , Hemorragia/epidemiologia , Hemorragia/induzido quimicamente , Hemorragia/etiologia , Pessoa de Meia-Idade , Finlândia/epidemiologia , Fatores de Risco , Varfarina/efeitos adversos , Varfarina/uso terapêutico , Medição de Risco , Fatores de Tempo
18.
PLoS One ; 19(6): e0301691, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38829846

RESUMO

Atrial Fibrillation (AF), a type of heart arrhythmia, becomes more common with aging and is associated with an increased risk of stroke and mortality. In light of the urgent need for effective automated AF monitoring, existing methods often fall short in balancing accuracy and computational efficiency. To address this issue, we introduce a framework based on Multi-Scale Dilated Convolution (AF-MSDC), aimed at achieving precise predictions with low cost and high efficiency. By integrating Multi-Scale Dilated Convolution (MSDC) modules, our model is capable of extracting features from electrocardiogram (ECG) datasets across various scales, thus achieving an optimal balance between precision and computational savings. We have developed three MSDC modules to construct the AF-MSDC framework and assessed its performance on renowned datasets, including the MIT-BIH Atrial Fibrillation Database and Physionet Challenge 2017. Empirical results unequivocally demonstrate that our technique surpasses existing state-of-the-art (SOTA) methods in the AF detection domain. Specifically, our model, with only a quarter of the parameters of a Residual Network (ResNet), achieved an impressive sensitivity of 99.45%, specificity of 99.64% (on the MIT-BIH AFDB dataset), and an [Formula: see text] score of 85.63% (on the Physionet Challenge 2017 AFDB dataset). This high efficiency makes our model particularly suitable for integration into wearable ECG devices powered by edge computing frameworks. Moreover, this innovative approach offers new possibilities for the early diagnosis of AF in clinical applications, potentially improving patient quality of life and reducing healthcare costs.


Assuntos
Fibrilação Atrial , Eletrocardiografia , Redes Neurais de Computação , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Humanos , Eletrocardiografia/métodos , Algoritmos , Bases de Dados Factuais
19.
BMJ Open ; 14(6): e075110, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38830741

RESUMO

INTRODUCTION: Screening for atrial fibrillation (AF) in the general population may help identify individuals at risk, enabling further assessment of risk factors and institution of appropriate treatment. Algorithms deployed on wearable technologies such as smartwatches and fitness bands may be trained to screen for such arrhythmias. However, their performance needs to be assessed for safety and accuracy prior to wide-scale implementation. METHODS AND ANALYSIS: This study will assess the ability of the WHOOP strap to detect AF using its WHOOP Arrhythmia Notification Feature (WARN) algorithm in an enriched cohort with a 2:1 distribution of previously diagnosed AF (persistent and paroxysmal) and healthy controls. Recruited participants will collect data for 7 days with the WHOOP wrist-strap and BioTel ePatch (electrocardiography gold-standard). Primary outcome will be participant level sensitivity and specificity of the WARN algorithm in detecting AF in analysable windows compared with the ECG gold-standard. Similar analyses will be performed on an available epoch-level basis as well as comparison of these findings in important subgroups. ETHICS AND DISSEMINATION: The study was approved by the ethics board at the study site. Participants will be enrolled after signing an online informed consent document. Updates will be shared via clinicaltrials.gov. The data obtained from the conclusion of this study will be presented in national and international conferences with publication in clinical research journals. TRIAL REGISTRATION NUMBER: NCT05809362.


Assuntos
Algoritmos , Fibrilação Atrial , Dispositivos Eletrônicos Vestíveis , Humanos , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Masculino , Feminino , Estudos Observacionais como Assunto , Pessoa de Meia-Idade , Adulto , Arritmias Cardíacas/diagnóstico
20.
Sci Rep ; 14(1): 12660, 2024 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-38831029

RESUMO

The optimal anesthetic agent for radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF) and its impact on the recovery profiles remain uncertain. We compared the recovery and hemodynamic parameters between the remimazolam-flumazenil and propofol groups during RFCA. Patients were randomized into the remimazolam-flumazenil and propofol groups. The primary outcome measure was the time to eye opening following the discontinuation of anesthetic agents. Secondary outcomes included time to extubation, time to discharge from the operating room, intraprocedural hemodynamic variables and postoperative quality outcomes. Fifty-three patients were included in the final analysis (n = 26 in the remimazolam-flumazenil and n = 27 in the propofol group). The time to eye opening was significantly shorter in the remimazolam-flumazenil group compared to the propofol group (median [interquartile range]: 174 [157-216] vs. 353 [230-483] s, P < 0.001). The mean blood pressure and bispectral index were significantly higher in the remimazolam-flumazenil group compared to the propofol group (mean difference [95% CI], 7.2 [1.7-12.7] mmHg and 6 [3-8]; P = 0.011 and < 0.001, respectively), which were within target ranges in both groups. Other secondary outcomes were comparable between the groups. Consequently, remimazolam emerges as a promising anesthetic agent, characterized by rapid recovery and stable hemodynamics, during RFCA of AF.Trial registration: NCT05397886.


Assuntos
Anestesia Geral , Fibrilação Atrial , Ablação por Cateter , Flumazenil , Propofol , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Propofol/administração & dosagem , Masculino , Feminino , Pessoa de Meia-Idade , Ablação por Cateter/métodos , Flumazenil/administração & dosagem , Anestesia Geral/métodos , Idoso , Período de Recuperação da Anestesia , Benzodiazepinas/administração & dosagem , Hemodinâmica/efeitos dos fármacos , Anestésicos Intravenosos/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA