Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.872
Filtrar
1.
Anal Methods ; 16(26): 4402-4408, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38904182

RESUMO

Myocardial infarction occurs rapidly, and thus the rapid detection of cTnI levels is the key to its diagnosis. Most current assays take 10-30 min. In this study, we developed a method for accurately measuring cardiac troponin I (cTnI) levels in human sera with amplified luminescence neighborhood homogeneous assay (AlphaLISA). The method involves coupling two cTnI antibodies targeting different epitopes to the surface of carboxylated donor and acceptor beads. The final signal values were detected by the double-antibody sandwich method, and the best reaction conditions were obtained by optimizing the experimental conditions. The sensitivity, specificity, accuracy, and precision of the method were evaluated. Results showed that the method requires only 3 min to produce the results, the detection sensitivity is 27.06 ng L-1, and the measurement range is 34.56-62 500 ng L-1. cTnI-AlphaLISA has an intra-assay precision of 2.18-4.57% (<10%) and an inter-assay precision of 5.60-6.95% (<10%). The relative recovery rates are within reasonable limits. In addition, the serum assay results of the method were compared with chemiluminescence immunoassay, and the results are in agreement with one another (ρ = 0.8803; P < 0.0001). The method is expected to be developed as a routine method, but further studies and evaluations are needed.


Assuntos
Microesferas , Troponina I , Troponina I/sangue , Troponina I/imunologia , Humanos , Limite de Detecção , Infarto do Miocárdio/sangue , Infarto do Miocárdio/diagnóstico , Reprodutibilidade dos Testes , Imunoensaio/métodos , Medições Luminescentes/métodos , Fluorimunoensaio/métodos , Sensibilidade e Especificidade
2.
J Immunol Methods ; 531: 113710, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38871279

RESUMO

When the membrane protein CD40 ligand (CD40L) on activated T cells binds the receptor CD40 on B-cells, it provides a co-stimulatory signal for B cell activation. Dysregulation of the CD40L:CD40 axis is associated with inflammatory and autoimmune diseases. The presence of soluble CD40L (sCD40L) in plasma is implicated in several diseases, from cardiovascular and autoimmune diseases to different types of cancer, and sCD40L has been suggested as a valuable marker of disease. If sCD40L is to be used as a biomarker, being able to precisely measure and quantify the levels of sCD40L in human blood samples is of utmost importance. We demonstrate the development of a sandwich-type time-resolved immunofluorometric assay for quantification of sCD40L in plasma or serum samples. For this, we generate 29 monoclonal anti-CD40L antibodies, and from these, we select the optimal combination of capture antibody and detection antibody. A number of variables were tested: the influence of the type of sample (comparing 3 different blood collection tubes for serum sampling and 4 different types of tubes for plasma sampling), the influence of freeze-thaw cycles, the influence of sampling time during night and day, and the influence of centrifugation of the samples. We found a very similar level of sCD40L in paired EDTA plasma and serum samples. Out of 100 healthy blood donor samples 61 had a level of sCD40L below the detection level of the assay, whereas the remaining 39 samples had ranging levels of sCD40L from 1.14 to 33.14 ng/mL. In summary, we present a time-resolved immunofluorometric assay based on paired monoclonal antibodies, ensuring high specificity, sensitivity, and homogeneity. The Eu3+-based assay additionally provides consistent assay readouts due to the extended decay time not seen in standard enzyme-linked immunosorbent assays. The assay paves the way for specific and consistent quantification of sCD40L in human plasma and serum samples.


Assuntos
Ligante de CD40 , Humanos , Ligante de CD40/sangue , Biomarcadores/sangue , Anticorpos Monoclonais/imunologia , Fluorimunoensaio/métodos , Reprodutibilidade dos Testes
3.
Luminescence ; 39(5): e4747, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38716575

RESUMO

Atezolizumab (ATZ) is a human monoclonal antibody, which has been granted multiple approvals from the US Food and Drug Administration (FDA) for the immunotherapy of different types of cancer. This study describes the prototype of a time-resolved fluoroimmunoassay (TRFIA) for the quantitation of ATZ in plasma. The assay involved the non-competitive binding of ATZ to its specific antigen [programmed death-ligand 1 (PD-L1) protein]. The immune complex formed on the inner surface of the assay plate wells was quantified by anti-human secondary antibody labeled with a chelate of europium-ethylenediaminetetraacetic acid. The enhanced fluorescence signal was generated by an enhanced fluorescence solution composed of thenoyltrifluoroacetone, trioctylphosphine oxide, and Triton X-100. The conditions of the TRFIA were refined, and its optimum procedures were established. The assay was validated in accordance with the immunoassay validation guidelines, and all the validation parameters were acceptable. The working range of the assay was 20-1000 pg mL-1, and its limit of quantitation was 20 pg mL-1. The assay was applied to the quantitation of ATZ in plasma samples with satisfactory accuracy and precision. The proposed TRFIA has significant benefits over the existing methodologies for the quantitation of ATZ in clinical settings.


Assuntos
Anticorpos Monoclonais Humanizados , Fluorimunoensaio , Fluorimunoensaio/métodos , Humanos , Anticorpos Monoclonais Humanizados/sangue , Anticorpos Monoclonais Humanizados/química , Anticorpos Monoclonais Humanizados/imunologia , Fluorescência , Fatores de Tempo
4.
Talanta ; 275: 126128, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38657361

RESUMO

Imidacloprid (IMI), the most commonly used neonicotinoid, is widely present in both the environment and agro-products due to extensive and prolonged application, posing potential risks to ecological security and human health. This study introduced a sensitive and rapid fluorescence-linked immunosorbent assay, employing Quantum Dot-Streptavidin conjugate (QDs-SA-FLISA), for efficient monitoring of IMI residues in agro-products. Under optimized conditions, the QDs-SA-FLISA exhibited a half-maximal inhibition concentration (IC50) of 1.70 ng/mL and a limit of detection (LOD, IC20) of 0.5 ng/mL. Investigation into the sensitivity enhancement effect of the QDs-SA revealed that the sensitivity (IC50) of the QDs-SA-FLISA was 7.3 times higher than that of ELISA. The recoveries and relative standard deviation (RSD) ranged from 81.7 to 118.1 % and 0.5-9.4 %, respectively, for IMI in brown rice, tomato and pear. There was no significant difference in IMI residues obtained between QDs-SA-FLISA and UHPLC-MS/MS. Thus, the QDs-SA-FLISA represents a reliable approach for the quantitative determination of IMI in agro-products.


Assuntos
Fluorimunoensaio , Neonicotinoides , Nitrocompostos , Pontos Quânticos , Estreptavidina , Pontos Quânticos/química , Neonicotinoides/análise , Neonicotinoides/química , Estreptavidina/química , Nitrocompostos/análise , Nitrocompostos/química , Fluorimunoensaio/métodos , Limite de Detecção , Oryza/química , Solanum lycopersicum/química , Pyrus/química , Contaminação de Alimentos/análise , Inseticidas/análise , Resíduos de Praguicidas/análise
5.
Anal Chim Acta ; 1302: 342514, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38580408

RESUMO

Monkeypox (mpox) is spreading around the world, and its rapid diagnosis is of great significance. In the present study, a rapid and sensitive fluorescent chromatography assisted with cloud system was developed for point-of-care diagnosis of mpox. To screen high affinity antibodies, nanoparticle antigen AaLS-A29 was generated by conjugating A29 onto scaffold AaLS. Immunization with AaLS-A29 induced significantly higher antibody titers and monoclonal antibodies were generated with the immunized mice. A pair of monoclonal antibodies, MXV 14 and MXV 15, were selected for fluorescence chromatography development. The Time-Resolved Fluorescence Immunoassay (TRFIA) was used to develop the chromatography assay. After optimization of the label and concentration of antibodies, a sensitive TRFIA assay with detection limit of 20 pg/mL and good repeatability was developed. The detection of the surrogate Vaccinia virus (VACA) strain Tian Tan showed that the TRFIA assay was more sensitive than the SYBR green I based quantitative PCR. In real samples, the detection result of this assay were highly consistent with the judgement of Quantitative Real-Time PCR (Concordance Rate = 90.48%) as well as the clinical diagnosis (Kappa Value = 0.844, P < 0.001). By combining the portable detection and online cloud system, the detection results could be uploaded and shared, making this detection system an ideal system for point-of-care diagnosis of mpox both in field laboratory and outbreak investigation.


Assuntos
Mpox , Animais , Camundongos , Sistemas Automatizados de Assistência Junto ao Leito , Fluorimunoensaio/métodos , Anticorpos Monoclonais
6.
J Agric Food Chem ; 72(12): 6772-6780, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38478886

RESUMO

Trimethoprim (TMP), functioning as a synergistic antibacterial agent, is utilized in diagnosing and treating diseases affecting livestock and poultry. Human consumption of the medication indirectly may lead to its drug accumulation in the body and increase drug resistance due to its prolonged metabolic duration in livestock and poultry, presenting significant health hazards. Most reported immunoassay techniques, such as ELISA and immunochromatographic assay (ICA), find it challenging to achieve the dual advantages of high sensitivity, simplicity of operation, and a wide detection range. Consequently, an open droplet microchannel-based magnetosensor for immunofluorometric assay (OMM-IFA) of trimethoprim was created, featuring a gel imager to provide a signal output derived from the highly specific antibody (Ab) targeting trimethoprim. The method exhibited high sensitivity in chicken and pork samples, with LODs of 0.300 and 0.017 ng/mL, respectively, and a wide linear range, covering trimethoprim's total maximum residue limits (MRLs). Additionally, the spiked recoveries in chicken and pork specimens varied between 81.6% and 107.9%, maintaining an acceptable variation coefficient below 15%, aligning well with the findings from the ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) technique. The developed method achieved a much wider linear range of about 5 orders of magnitude of 10-2-103 levels with grayscale signals as the output signal, which exhibited high sensitivity, excellent applicability and simple operability based on magnetic automation.


Assuntos
Carne de Porco , Carne Vermelha , Animais , Humanos , Suínos , Trimetoprima , Cromatografia Líquida , Galinhas , Espectrometria de Massas em Tandem/métodos , Aves Domésticas , Fluorimunoensaio , Cromatografia Líquida de Alta Pressão/métodos
7.
Anal Chim Acta ; 1293: 342283, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38331551

RESUMO

Recombinant antibody-based immunoassays have emerged as crucial techniques for detecting antibiotic residues in food samples. Developing a stable recombinant antibody production system and enhancing detection sensitivity are crucial for their biosensing applications. Here, we bioengineered a single-chain fragment variable (scFv) antibody to target chloramphenicol (CAP) using both Bacillus subtilis and HEK 293 systems, with the HEK 293-derived scFv demonstrating superior sensitivity. Computational chemistry analyses indicated that ASP-99 and ASN-102 residues in the scFv play key roles in antibody recognition, and the hydroxyl group near the benzene ring of the target molecule is critical for in antibody binding. Furthermore, we enhanced the scFv's biosensing sensitivity using an HCR-CRISPR/Cas12a amplification strategy in a streptavidin-based immunoassay. In the dual-step amplification process, detection limits for CAP in the HCR and HCR-CRISPR/Cas12a stages were significantly reduced to 55.23 pg/mL and 3.31 pg/mL, respectively. These findings introduce an effective method for developing CAP-specific scFv antibodies and also propose a multi-amplification strategy to increase immunoassay sensitivity. Additionally, theoretical studies also offer valuable guidance in CAP hapten design and genetic engineering for antibody modification.


Assuntos
Técnicas Biossensoriais , Cloranfenicol , Humanos , Sistemas CRISPR-Cas , Células HEK293 , Hibridização de Ácido Nucleico , Fluorimunoensaio , Anticorpos
8.
Anal Chem ; 96(10): 4005-4012, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38415592

RESUMO

We demonstrate the synthesis of biogenic supported silver spiked star architectures and their application to increase the electromagnetic field intensity at its tips that enhance plasmon-coupled emission. Tecoma stans floral extract has been used to synthesize silver nanocubes and spiked stars. We observe ∼445-fold and ∼680-fold enhancements in spacer and cavity configurations, respectively, in the SPCE platform. The hotspot intensity and Purcell factor are evaluated by carrying out finite-difference time-domain (FDTD) simulations. Time-based studies are presented to modulate the sharpness of the edges wherein an increase in the tip sharpness with the increase in reaction time up to 5 h is observed. The unique morphology of the silver architectures allowed us to utilize them in biosensing application. A SPCE-based fluoroimmunoassay was performed, achieving a 1.9 pg/mL limit of detection of TNF-α cytokine. This combination of anisotropic architectures, SPCE and immunoassay prove to be a powerful platform for the ultrasensitive detection of biomarkers in surface-bound assays.


Assuntos
Bignoniaceae , Ressonância de Plasmônio de Superfície , Prata , Fluorimunoensaio , Extratos Vegetais
9.
Anal Biochem ; 689: 115494, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38403258

RESUMO

Invasive Aspergillosis is a high-risk illness with a high death rate in immunocompromised people due to a lack of early detection and timely treatment. Based on immunology study, we achieved an efficient production of anti-galactomannan antibody by Chinese hamster ovary (CHO) cells and applied it to time-resolved fluoroimmunoassay for Aspergillus galactomannan detection. We first introduced dual promoter expression vector into CHO host cells, and then applied a two-step screening strategy to screen the stable cell line by methionine sulfoximine pressurization. After amplification and fermentation, antibody yield reached 4500 mg/L. Then we conjugated the antibodies with fluorescent microspheres to establish a double antibody sandwich time-resolved fluoroimmunoassay, which was compared with the commercial Platelia™ Aspergillus Ag by clinical serum samples. The preformed assay could obtain the results in less than 25 min, with a limit of detection for galactomannan of approximately 1 ng/mL. Clinical results of the two methods showed that the overall percent agreement was 97.7% (95% CI: 96.6%-98.4%) and Cohen's kappa coefficient was 0.94. Overall, the assay is highly consistent with commercial detection, providing a more sensitive and effective method for the rapid diagnosis of invasive aspergillosis.


Assuntos
Aspergilose , Aspergillus , Galactose/análogos & derivados , Animais , Cricetinae , Humanos , Células CHO , Cricetulus , Aspergilose/diagnóstico , Mananas , Fluorimunoensaio , Anticorpos Monoclonais
10.
Nano Lett ; 24(1): 229-237, 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38146928

RESUMO

Rapid and accurate quantification of low-abundance protein biomarkers in biofluids can transform the diagnosis of a range of pathologies, including infectious diseases. Here, we harness ultrabright plasmonic fluors as "digital nanolabels" and demonstrate the detection and quantification of subfemtomolar concentrations of human IL-6 and SARS-CoV-2 alpha and variant proteins in clinical nasopharyngeal swab and saliva samples from COVID-19 patients. The resulting digital plasmonic fluor-linked immunosorbent assay (digital p-FLISA) enables detection of SARS-CoV-2 nucleocapsid protein, both in solution and in live virions. Digital p-FLISA outperforms the "gold standard" enzyme-linked immunosorbent assay (ELISA), having a nearly 7000-fold lower limit-of-detection, and outperforms a commercial antigen test, having over 5000-fold improvement in analytical sensitivity. Detection and quantification of very low concentrations of target proteins holds potential for early detection of pathological conditions, treatment monitoring, and personalized medicine.


Assuntos
COVID-19 , Humanos , Ensaio de Imunoadsorção Enzimática , COVID-19/diagnóstico , Fluorimunoensaio , SARS-CoV-2 , Biomarcadores , Sensibilidade e Especificidade
11.
Anal Methods ; 15(35): 4541-4547, 2023 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-37642087

RESUMO

Immunoassays are commonly used in disease diagnosis and vaccine evaluation but can be costly and time-consuming when confronted with multivalent targets, such as antisera containing antibodies to human papillomavirus (HPV), because of their limited ability to discriminate between multiple analytes in a single reaction well. This study describes the development of a high-throughput liquid chip system that combines immunoassay techniques and magnetic beads to allow the simultaneous screening and quantitative detection of antibodies to four types of HPV using the Luminex fluoroimmunoassay system. Groups of beads embedded with fluorescent dyes at various ratios were coated with optimized HPV capture antigens and demonstrated excellent dose-dependent response to four monoclonal antibodies used as reference standards. This assay is sensitive, accurate, repeatable, and simple to perform, enabling multiplex antibody detection with a high degree of orthogonality. The performance of the Luminex system was compared with conventional immunoassays for quantitative detection of quadrivalent HPV antibodies in antisera of mice immunized with five lots of HPV vaccines, verifying the accuracy and detection efficiency of the assay. This strategy is a promising approach to characterizing antibodies present in polyclonal antisera and has promising applications in research, clinical, and industrial settings, for example, streamlining vaccine efficacy trials and vaccine lot inspection and release procedures.


Assuntos
Papillomavirus Humano , Infecções por Papillomavirus , Humanos , Animais , Camundongos , Infecções por Papillomavirus/diagnóstico , Anticorpos Antivirais , Fluorimunoensaio , Soros Imunes , Antígenos Virais
12.
J Immunol Methods ; 520: 113534, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37558124

RESUMO

AIM: This study aimed to establish a highly sensitive time-resolved fluorescence immunoassay of growth stimulating express gene 2 protein (ST2-TRFIA) and evaluate its application value for sepsis. METHODS: Two types of ST2 monoclonal specific antibodies against different epitopes of antigen molecule were used as coating and Eu3+-labeled antibodies. The double-antibody sandwich method was used in establishing ST2-TRFIA, and the methodology was evaluated. The established ST2-TRFIA was used in detecting ST2 concentration in the plasma samples of healthy controls and sepsis. RESULTS: The linear range of ST2-TRFIA was 1.446-500 ng/mL. Plasma ST2 concentrations detected through ST2-TRFIA were consistent with the results of fluorescence quantitative immunochromatography (ρ = 0.946). The plasma ST2 concentrations of patients with sepsis were significantly higher than those of healthy controls (P < 0.01). CONCLUSION: This study successfully established a highly sensitive ST2-TRFIA, which was highly comparable to commercially available fluorescent quantitative immunochromatographic kits and can facilitate the timely diagnosis of sepsis.


Assuntos
Proteína 1 Semelhante a Receptor de Interleucina-1 , Sepse , Humanos , Fluorimunoensaio/métodos , Anticorpos Monoclonais , Sepse/diagnóstico , Sensibilidade e Especificidade
13.
Virol J ; 20(1): 166, 2023 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-37501131

RESUMO

BACKGROUND: Chikungunya virus (CHIKV) and Dengue virus (DENV) have similar clinical symptoms, which often induce misdiagnoses. Therefore, an antigen detection diagnostic system that can clearly identify these two viruses is desirable. METHODS: In this study, we developed a novel peptide with high affinity and specificity to CHIKV, and further constructed peptide aptamer-based TRFIA assay to efficiently detect CHIKV. Peptide aptamer B2 (ITPQSSTTEAEL) and B3 (DTQGSNWI) were obtained through computer-aided design and selected as CHIKV-specific peptide aptamers based on their high binding affinity, strong hydrogen bonding, and RMSD of molecular docking. Then, a sandwich-Time-Resolved Fluoroimmunoassay (TRFIA) was successfully constructed for the detection of the interaction between peptide aptamers and viruses. RESULTS: When using B2 as the detection element, highly specific detection of CHIKV E2 was achieved with detection limits of 8.5 ng/ml in PBS solution. Variation coefficient between inter-assay showed the disturbances received from the detection of clinical fluid specimens (including serum and urine), were also within acceptable limits. The detection limits for 10-fold dilution serum and urine were 57.8 ng/mL and 147.3 ng/mL, respectively. The fluorescent signal intensity exhibited a good linear correlation with E2 protein concentration in the range of 0-1000 ng/mL, indicating the potential for quantitative detection of E2 protein. CONCLUSIONS: These results demonstrate that the construction of peptide aptamers with high affinity and specificity provides an excellent method for rapid diagnostic element screening, and the developed peptide aptamer B2 contributed to better detection of CHIKV viral particles compared to traditional antibodies.


Assuntos
Aptâmeros de Peptídeos , Febre de Chikungunya , Vírus Chikungunya , Dengue , Humanos , Febre de Chikungunya/diagnóstico , Simulação de Acoplamento Molecular , Fluorimunoensaio
14.
J Virol Methods ; 318: 114752, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37209780

RESUMO

Host cell proteins (HCPs) are the process-specific and inevitable impurities during the manufacture via a host cell, which affect the safety or efficacy of the bio-product. However, the commercial HCP enzyme-linked immunosorbent assay (ELISA) kits may not apply to specific products such as rabies vaccine from Vero cells. More advanced and process-specific assay methods are needed in the quality control of rabies vaccine throughout the whole manufacturing process. Therefore, a novel time-resolved fluoroimmunoassay (TRFIA) for the detection of process-specific HCP of Vero cells in rabies vaccine was established in this study. Liquid chromatography coupled tandem mass spectrometry (LC-MS/MS) was used during the preparation of HCP antigen. Based on a sandwich-type immunoassay format, analytes in samples were captured by one antibody coating in the wells and "sandwiched" by another antibody labeled with europium chelates. Due to the complex composition of HCP, both the capture and detected antibodies are polyclonal antibodies from the same anti-HCP antibodies pool. Multiple experiments have identified the optimal conditions to allow the valid and reliable detection of HCP in rabies vaccine. The TRFIA had a satisfactory limit of detection value (0.011 µg/ml) under optimal conditions, with the linear range from 0.0375 to 2.4 µg/ml of HCP. The coefficient variations (CVs) were all < 10%, and the recoveries were in the range of 97.00-102.42%. All the test results of Vero cell protein reference substance were included in the expected concentration, which demonstrated that the present method was available for the test of HCP in rabies vaccine. Based on these results, the novel TRFIA to detect HCP appears to be important for application in modern vaccine quality control during the whole manufacturing process.


Assuntos
Vacina Antirrábica , Animais , Chlorocebus aethiops , Cromatografia Líquida/métodos , Células Vero , Espectrometria de Massas em Tandem/métodos , Proteínas/análise , Proteínas/química , Proteínas/metabolismo , Anticorpos , Fluorimunoensaio/métodos
15.
Gen Comp Endocrinol ; 340: 114305, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37149009

RESUMO

Insulin-like growth factor (IGF)-1 promotes the growth of vertebrates, and its binding proteins (IGFBPs) regulate the activity of circulating IGF-1. Three IGFBPs, IGFBP-2b, -1a, and -1b, were consistently detected in the circulatory system of salmonids. IGFBP-2b is thought to be the main carrier of IGFs and promoter of IGF-1-mediated growth in salmonids. Currently, there are no immunoassays for detecting IGFBP-2b. In this study, we developed a time-resolved fluoroimmunoassay (TR-FIA) for IGFBP-2b detection in salmonid fishes. To establish TR-FIA, we produced two recombinant trout (rt) IGFBP-2bs expressed, one with thioredoxin (Trx) and a histidine (His) tag, and the other with His-tag only. We labeled both recombinant proteins with europium (Eu). Only Eu-Trx.His.rtIGFBP-2b cross-reacted with anti-IGFBP-2b, and the addition of increasing amounts of Trx.His.rtIGFBP-2b replaced the binding, indicating its utility as a tracer and assay standard. The addition of unlabeled salmon IGF-1 did not affect the binding of the standard or sample. Serial dilution curves of sera from rainbow trout, Chinook salmon, and chum salmon were parallel to those of the standard. The assay range (ED80-ED20) of the TR-FIA was 60.4 to 251.3 ng/ml, and its minimum detection limit of this assay was 21 ng/ml. The intra- and inter-assay coefficients of variation were 5.68% and 5.65%, respectively. Circulating IGFBP-2b levels in fed rainbow trout were higher than those in fasted fish and were correlated with individual growth rates. This TR-FIA is useful for further exploring the physiological responses of circulating IGFBP-2b and evaluating the growth status of salmonids.


Assuntos
Fator de Crescimento Insulin-Like I , Oncorhynchus mykiss , Animais , Fator de Crescimento Insulin-Like I/metabolismo , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/metabolismo , Salmão , Fluorimunoensaio , Oncorhynchus mykiss/metabolismo , Fator de Crescimento Insulin-Like II/metabolismo
16.
Anal Biochem ; 666: 115072, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36738873

RESUMO

AIM: To develop a highly sensitive time-resolved fluorescence immunoassay (TRFIA) for the detection of serum matrix metalloproteinase-3 (MMP-3) and to assess MMP-3's clinical value in patients with colorectal cancer (CRC).st. METHODS: MMP-3 levels were established using the double antibody sandwich technique. The MMP-3 TRFIA technique was developed and optimized, and its linearity, sensitivity, accuracy, specificity, and recovery were assessed. Then, serum concentrations in healthy individuals and patients with CRC were determined by MMP-3 TRFIA. RESULTS: The linear range of MMP-3 TRFIA was 0.73-500 ng/mL. MMP-3 TRFIA had an intra-batch precision range of 2.16%-7.10% percent and an inter-batch precision range of 3.99%-11.21%. MMP-3, tumor-associated trypsinogen 2, and AFP had no cross reaction.The recovery is between 90% and 110%, and had no serum interference. Patients with CRC had serum MMP-3 levels (73.95 ± 78.43 ng/mL) that were considerably higher than those of healthy individuals (21.45 ± 11.12 ng/mL), and those with metastasis had serum MMP-3 levels (95.89 ± 76.21 ng/mL) that were considerably higher than those of patients without metastasis (52.74 ± 47.25 ng/mL). CONCLUSIONS: A highly sensitive MMP-3 TRFIA assay was successfully developed, and serum MMP-3 may be associated with CRC invasion and metastasis. Therefore, MMP-3 can be used in the auxiliary diagnosis of CRC.


Assuntos
Fluorimunoensaio , Metaloproteinase 3 da Matriz , Humanos , Fluorimunoensaio/métodos , Soro , Anticorpos
17.
Sci Total Environ ; 855: 158897, 2023 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-36411601

RESUMO

Rapid detection technology of aquaculture fishery drug residues is needed to supplement large-scale instrument methods. To do this, the time-resolved fluorescence immunoassay (TRFIA) method and portable three-dimensional (3D) printing equipment platform were used, in combination with smartphones, to detect malachite green (MG) in pond sediments. The TRFIA was coupled to MG monoclonal antibodies (mAb) through lanthanide metal microspheres europium (Eu3+). The labeled antibody produced competitive immunity in the immune reaction system, and the specific fluorescence intensity in the product was determined by a portable 3D printing equipment platform to achieve quantitative analysis. To test this method, leucomalachite green (LMG) was converted to MG by oxidation of dicyanoquinone (DDQ), and a qualitative analysis was achieved. Methodological evaluation results were satisfactory, recoveries were 83 %-104 %, the limit of detection (LOD) was 0.3 ng/g, the limit of quantitation (LOQ) was 0.7 ng/g, and the coefficient of variation was 1.3 %-7.3 %. The linear equation y = -0.1496x + 0.5585 was in the range of 0-10 ng/g. The linear regression correlation coefficient was 99.2 %. The TRFIA was confirmed and positive samples were measured. Results were consistent with the standard method, which demonstrated that the TRFIA was feasible and that the detection results were reliable. Compared with the national standard method, the TRFIA saves time, is more convenient, and has high sensitivity. It provides an efficient technical method for the rapid screening of MG in the sediments of aquaculture environments.


Assuntos
Fluorimunoensaio , Impressão Tridimensional , Imunofluorescência , Microesferas
18.
BMC Biotechnol ; 22(1): 27, 2022 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-36180909

RESUMO

BACKGROUND: Lymphocytic leukemia (LL) is a primary malignant tumor of hematopoietic tissue, which seriously affects the health of children and the elderly. The study aims to establish a new detection method for screening acute/chronic LL using time-resolved fluorescence immunoassay (TRFIA) via quantitative detection of S100 calcium binding protein A8 (S100A8) and leucine-rich alpha-2-glycoprotein 1 (LRG1) in serum. METHODS: Here a sandwich TRFIA was optimized and established: Anti-S100A8/LRG1 caputre antibodies immobilized on 96-well plates captured S100A8/LRG1, and then banded together with the anti-S100A8/LRG1 detection antibodies labeled with Europium(III) (Eu3+)/samarium(III) (Sm3+) chelates. Finally time resolved fluorometry measured the fluorescence intensity. RESULTS: The sensitivity of S100A8 was 1.15 ng/mL(LogY = 3.4027 + 0.4091 × LogX, R2 = 0.9828, P < 0.001, dynamic range: 2.1-10,000 ng/mL), and 3.2 ng/mL for LRG1 (LogY = 3.3009 + 0.4082 × LogX, R2 = 0.9748, P < 0.001, dynamic range: 4.0-10,000 ng/mL). The intra-assay and inter-assay CVs were low, ranging from 5.75% to 8.23% for S100A8 and 5.30% to 9.45% for LRG1 with high specificity and affinity in serum samples. Bland-Altman plots indicated TRFIA and ELISA kits have good agreement in clinical serum samples. Additionally, the cutoff values for S100A8 and LRG1 were 1849.18 ng/mL and 588.08 ng/mL, respectively. CONCLUSION: The present TRFIA method could be used for the quantitative detection of S100A8 and LRG1 in serum, and it has high sensitivity, accuracy and specificity. Clinically, this TRFIA method could be suitable for screening of LL via the quantitative detection of S100A8 and LRG1.


Assuntos
Európio , Leucemia Linfocítica Crônica de Células B , Idoso , Proteínas de Ligação ao Cálcio , Criança , Fluorimunoensaio/métodos , Glicoproteínas , Humanos , Leucina , Leucemia Linfocítica Crônica de Células B/diagnóstico , Samário , Sensibilidade e Especificidade
19.
Anal Bioanal Chem ; 414(24): 7143-7151, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36006431

RESUMO

In recent years, more and more functional peptide ligands have been identified from phage display libraries and served the immunoassay of small molecules. After the identification, the phage particle instead limits further application of peptide ligands, so it is of great significance to explore the peptide ligand as an independent detection reagent. In this work, the identified peptidomimetic of benzothiostrobin was synthesized and labelled with biotin, which was combined with Eu3+-labelled streptavidin to develop the peptide-based time-resolved fluoroimmunoassay (P-TRFIA). Under the optimal conditions, the half-maximum inhibitory concentration (IC50) of proposed P-TRFIA is 3.63 ng mL-1, which is similar to the TRFIA using phage-borne peptidomimetic and Eu3+-labelled anti-phage antibody (IC50: 4.55 ng mL-1), also more sensitive than previously reported immunoassays for benzothiostrobin. In addition, the proposed P-TRFIA shows excellent specificity and accuracy for analysis of spiked samples, and its detection results shows good consistency with high-performance liquid chromatography for the detection of environment and agro-products samples with unknown benzothiostrobin concentrations.


Assuntos
Biotina , Peptidomiméticos , Acrilatos , Benzotiazóis , Fluorimunoensaio/métodos , Ligantes , Peptídeos/química , Sensibilidade e Especificidade , Estreptavidina
20.
J Clin Lab Anal ; 36(9): e24603, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35870181

RESUMO

AIM: To establish a highly sensitive time-resolved fluorescence immunoassay (TRFIA) of kidney injury molecule-1 (Kim-1) and evaluate its clinical value in acute kidney injury (AKI). METHODS: The Kim-1-TRFIA was established by the double-antibody sandwich method, and the method was evaluated. The established Kim-1-TRFIA was used to detect the concentration of Kim-1 in the serum of healthy controls and patients with AKI. RESULTS: The optimal coating antibody concentration and optimal Eu3+ -labeled antibody dilution ratio for Kim-1-TRFIA are 1 µg/ml and 1:140, respectively. The linear range is 42.71-4666.69 pg/ml. The intra- and inter-assay coefficients of variation are <10%. The specificity of our Kim-1-TRFIA is acceptable. The recovery is between 95.14% and 102.84%. The concentration of Kim-1 in the serum of patients with AKI is 126.50 ± 67.99 pg/ml, which is significantly higher than that in the serum of healthy controls (49.72 ± 16.40 pg/ml, p < 0.001). Staging patients with AKI by glomerular filtration rate shows that the serum concentration of Kim-1 increases significantly with increasing disease severity (p < 0.05). CONCLUSION: A highly sensitive Kim-1-TRFIA was established. With this immunoassay, a good differential diagnosis can be made, and healthy people and AKI patients can be differentiated by detecting the concentration of Kim-1 in the serum. Moreover, the severity of AKI patients can be determined.


Assuntos
Injúria Renal Aguda , Injúria Renal Aguda/diagnóstico , Biomarcadores , Fluorimunoensaio/métodos , Receptor Celular 1 do Vírus da Hepatite A , Humanos , Imunoensaio/métodos , Testes Imunológicos , Soro
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...