Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.581
Filtrar
1.
Sensors (Basel) ; 24(18)2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39338811

RESUMO

This comprehensive review offers a thorough examination of fetal heart rate (fHR) monitoring methods, which are an essential component of prenatal care for assessing fetal health and identifying possible problems early on. It examines the clinical uses, accuracy, and limitations of both modern and traditional monitoring techniques, such as electrocardiography (ECG), ballistocardiography (BCG), phonocardiography (PCG), and cardiotocography (CTG), in a variety of obstetric scenarios. A particular focus is on the most recent developments in textile-based wearables for fHR monitoring. These innovative devices mark a substantial advancement in the field and are noteworthy for their continuous data collection capability and ergonomic design. The review delves into the obstacles that arise when incorporating these wearables into clinical practice. These challenges include problems with signal quality, user compliance, and data interpretation. Additionally, it looks at how these technologies could improve fetal health surveillance by providing expectant mothers with more individualized and non-intrusive options, which could change the prenatal monitoring landscape.


Assuntos
Monitorização Fetal , Frequência Cardíaca Fetal , Têxteis , Dispositivos Eletrônicos Vestíveis , Humanos , Frequência Cardíaca Fetal/fisiologia , Gravidez , Feminino , Monitorização Fetal/métodos , Monitorização Fetal/instrumentação , Eletrocardiografia/métodos , Cardiotocografia/métodos , Cardiotocografia/instrumentação , Fonocardiografia/métodos , Balistocardiografia/métodos
2.
J Matern Fetal Neonatal Med ; 37(1): 2377718, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39128870

RESUMO

OBJECTIVE: To determine cardiotocographic patterns in newborns with metabolic acidosis, based on clinical signs of neurological alteration (NA) and the need for hypothermic treatment. METHODS: All term newborns with metabolic acidosis in a single center from 2016 to 2020 were included in the study. Three segments of intrapartum CTG (cardiotocography) were considered (first 30 min of active labor, 90 to 30 min before birth, and last 30 min before delivery) and a longitudinal analysis of CTG pattern was performed according to the 2015 FIGO classification. RESULTS: Three hundred and twenty-four neonates with metabolic acidosis diagnosed at birth were divided into three groups: the first group included all neonates with any clinical sign of neurological alteration, requiring hypothermia according to the recommendation of the Italian Society of Neonatology (group TNA-Treated neurological Alteration, n = 17), the second encompassed neonates with any clinical sign of neurological alteration not requiring hypothermia (group NTNA-Not Treated neurological Alteration, n = 83), and the third enclosed all neonates without any sign of clinical neurological involvement (group NoNA-No neurological Alteration, n = 224). The most frequent alterations of CTG in TNA group were late decelerations, reduced variability, bradycardia, and tachysystole. Unexpectedly, from the longitudinal analysis of the CTG, 49% of all cases with metabolic acidosis never showed a pathological CTG with normal trace at the beginning of labor followed by normal or suspicious trace in the final part of labor, the same as in TNA and NTNA groups (10 and 39%, respectively). CONCLUSIONS: CTG has limited specificity in identifying cases of acidosis at birth, even in babies who will develop NA.


Assuntos
Acidose , Cardiotocografia , Humanos , Recém-Nascido , Cardiotocografia/métodos , Acidose/diagnóstico , Feminino , Gravidez , Masculino , Hipotermia Induzida , Estudos Retrospectivos , Frequência Cardíaca Fetal/fisiologia , Doenças do Sistema Nervoso/diagnóstico
4.
J Matern Fetal Neonatal Med ; 37(1): 2394845, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39198035

RESUMO

OBJECTIVE: New guidelines for the interpretation of cardiotocography (CTG) have been presented by FIGO in 2015 (FIGO-15) and by NICE in 2017 (NICE-17) and 2022 (NICE-22) In Sweden, a previous template from 2009 (SWE-09) was replaced in 2017 (SWE-17).The objective of the study was to compare these five different templates for CTG classification regarding sensitivity, specificity, positive and negative predictive values in identifying neonates with acidemia at birth (cord artery pH <7.10). METHODS: This is a historical cohort study including singleton births in Lund November 2015-February 2016, after spontaneous or induced labor at ≥34 completed gestational weeks with validated umbilical cord acid-base samples.Characteristics of cardiotocographic traces during the last hour before birth were reviewed by two independent assessors blinded to outcome. Each template was then used to classify the CTG as normal, suspicious, or pathological. Traces for which classification differed between the two assessors for any of the templates were assessed by a third assessor. The classification by majority (at least 2 of 3) was used for analyses.Main outcome measures were the sensitivity, specificity, and positive and negative predictive values for each template to identify neonates with cord artery pH <7.10 by the classification pathological. In a secondary analysis, these outcome measures were calculated for the classifications suspicious + pathological together. RESULTS: SWE-09 and NICE-22 had significantly higher sensitivity (both 92%; 95% CI 79-98%) than NICE-17 (68%; 51-82%), FIGO-15 (42%; 26-59%) and SWE-17 (39%; 24-57%) to identify neonates with acidemia by the classification pathological. Specificity was significantly higher for SWE-17 (91%; 88-93%), FIGO-15 (90%; 88-93%) and NICE-17 (78%; 74-81%) than for NICE-22 (63%; 59-67%) and SWE-09 (62%; 58-66%). The positive predictive value of a pathological pattern ranged between 15% (SWE-09 and NICE-22) and 24% (FIGO-15), and negative predictive values between 95% (SWE-17) and 99% (SWE-09 and NICE-22). Combining suspicious and pathological patterns increased the sensitivity and decreased the specificity for all templates. CONCLUSIONS: Current CTG interpretation templates either have low sensitivity to identify fetal acidemia or low specificity. Among current guidelines, NICE 2022 had the highest sensitivity to identify neonates with acidemia and is considered the safest current classification system. Efforts to further improve diagnostic precision are warranted.


Assuntos
Acidose , Cardiotocografia , Humanos , Cardiotocografia/classificação , Cardiotocografia/estatística & dados numéricos , Feminino , Gravidez , Recém-Nascido , Acidose/diagnóstico , Acidose/sangue , Estudos de Coortes , Sensibilidade e Especificidade , Adulto , Valor Preditivo dos Testes , Suécia , Trabalho de Parto , Guias de Prática Clínica como Assunto , Frequência Cardíaca Fetal/fisiologia
5.
Hum Reprod ; 39(10): 2240-2248, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39173597

RESUMO

STUDY QUESTION: Could an artificial intelligence (AI) algorithm predict fetal heartbeat from images of vitrified-warmed embryos? SUMMARY ANSWER: Applying AI to vitrified-warmed blastocysts may help predict which ones will result in implantation failure early enough to thaw another. WHAT IS KNOWN ALREADY: The application of AI in the field of embryology has already proven effective in assessing the quality of fresh embryos. Therefore, it could also be useful to predict the outcome of frozen embryo transfers, some of which do not recover their pre-vitrification volume, collapse, or degenerate after warming without prior evidence. STUDY DESIGN, SIZE, DURATION: This retrospective cohort study included 1109 embryos from 792 patients. Of these, 568 were vitrified blastocysts cultured in time-lapse systems in the period between warming and transfer, from February 2022 to July 2023. The other 541 were fresh-transferred blastocysts serving as controls. PARTICIPANTS/MATERIALS, SETTING, METHODS: Four types of time-lapse images were collected: last frame of development of 541 fresh-transferred blastocysts (FTi), last frame of 467 blastocysts to be vitrified (PVi), first frame post-warming of 568 vitrified embryos (PW1i), and last frame post-warming of 568 vitrified embryos (PW2i). After providing the images to the AI algorithm, the returned scores were compared with the conventional morphology and fetal heartbeat outcomes of the transferred embryos (n = 1098). The contribution of the AI score to fetal heartbeat was analyzed by multivariate logistic regression in different patient populations, and the predictive ability of the models was measured by calculating the area under the receiver-operating characteristic curve (ROC-AUC). MAIN RESULTS AND THE ROLE OF CHANCE: Fetal heartbeat rate was related to AI score from FTi (P < 0.001), PW1i (P < 0.05), and PW2i (P < 0.001) images. The contribution of AI score to fetal heartbeat was significant in the oocyte donation program for PW2i (odds ratio (OR)=1.13; 95% CI [1.04-1.23]; P < 0.01), and in cycles with autologous oocytes for PW1i (OR = 1.18; 95% CI [1.01-1.38]; P < 0.05) and PW2i (OR = 1.15; 95% CI [1.02-1.30]; P < 0.05), but was not significantly associated with fetal heartbeat in genetically analyzed embryos. AI scores from the four groups of images varied according to morphological category (P < 0.001). The PW2i score differed in collapsed, non-re-expanded, or non-viable embryos compared to normal/viable embryos (P < 0.001). The predictability of the AI score was optimal at a post-warming incubation time of 3.3-4 h (AUC = 0.673). LIMITATIONS, REASONS FOR CAUTION: The algorithm was designed to assess fresh embryos prior to vitrification, but not thawed ones, so this study should be considered an external trial. WIDER IMPLICATIONS OF THE FINDINGS: The application of predictive software in the management of frozen embryo transfers may be a useful tool for embryologists, reducing the cancellation rates of cycles in which the blastocyst does not recover from vitrification. Specifically, the algorithm tested in this research could be used to evaluate thawed embryos both in clinics with time-lapse systems and in those with conventional incubators only, as just a single photo is required. STUDY FUNDING/COMPETING INTERESTS: This study was supported by the Regional Ministry of Innovation, Universities, Science and Digital Society of the Valencian Community (CIACIF/2021/019) and by Instituto de Salud Carlos III (PI21/00283), and co-funded by European Union (ERDF, 'A way to make Europe'). M.M. received personal fees in the last 5 years as honoraria for lectures from Merck, Vitrolife, MSD, Ferring, AIVF, Theramex, Gedeon Richter, Genea Biomedx, and Life Whisperer. There are no other competing interests. TRIAL REGISTRATION NUMBER: N/A.


Assuntos
Algoritmos , Inteligência Artificial , Blastocisto , Transferência Embrionária , Frequência Cardíaca Fetal , Vitrificação , Humanos , Feminino , Estudos Retrospectivos , Blastocisto/fisiologia , Gravidez , Frequência Cardíaca Fetal/fisiologia , Transferência Embrionária/métodos , Criopreservação/métodos , Imagem com Lapso de Tempo/métodos , Adulto , Técnicas de Cultura Embrionária
6.
Acta Obstet Gynecol Scand ; 103(10): 1910-1918, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39107951

RESUMO

Relative uteroplacental insufficiency of labor (RUPI-L) is a clinical condition that refers to alterations in the fetal oxygen "demand-supply" equation caused by the onset of regular uterine activity. The term RUPI-L indicates a condition of "relative" uteroplacental insufficiency which is relative to a specific stressful circumstance, such as the onset of regular uterine activity. RUPI-L may be more prevalent in fetuses in which the ratio between the fetal oxygen supply and demand is already slightly reduced, such as in cases of subclinical placental insufficiency, post-term pregnancies, gestational diabetes, and other similar conditions. Prior to the onset of regular uterine activity, fetuses with a RUPI-L may present with normal features on the cardiotocography. However, with the onset of uterine contractions, these fetuses start to manifest abnormal fetal heart rate patterns which reflect the attempt to maintain adequate perfusion to essential central organs during episodes of transient reduction in oxygenation. If labor is allowed to continue without an appropriate intervention, progressively more frequent, and stronger uterine contractions may result in a rapid deterioration of the fetal oxygenation leading to hypoxia and acidosis. In this Commentary, we introduce the term relative uteroplacental insufficiency of labor and highlight the pathophysiology, as well as the common features observed in the fetal heart rate tracing and clinical implications.


Assuntos
Insuficiência Placentária , Humanos , Feminino , Gravidez , Insuficiência Placentária/fisiopatologia , Frequência Cardíaca Fetal/fisiologia , Cardiotocografia , Contração Uterina/fisiologia , Complicações do Trabalho de Parto , Trabalho de Parto/fisiologia
7.
Ann Afr Med ; 23(2): 154-159, 2024 Apr 01.
Artigo em Francês, Inglês | MEDLINE | ID: mdl-39028163

RESUMO

BACKGROUND: Admission cardiotocography (CTG), a noninvasive procedure, is used to indicate the state of oxygenation of the fetus on admission into the labor ward. OBJECTIVE: This study assessed the association of admission CTG findings with neonatal outcome at a tertiary health facility. MATERIALS AND METHODS: A prospective, observational study of 206 pregnant women who were admitted into the labor ward with singleton live pregnancies. Information on the demographic characteristics, obstetrics and medical history, admission CTG tracing, and neonatal outcome was obtained using a structured data collection form. Data were analyzed using the SPSS software version 20.0 with the level of significance set at P < 0.05. RESULTS: The admission CTG findings were normal in 73.3%, suspicious in 13.6%, and pathological in 13.1% of the women. The occurrence of low birth weight, special care baby unit (SCBU) admission, asphyxiated neonates, neonatal death, and prolonged hospital admission was significantly more frequent among those with pathological admission CTG results compared with normal and suspicious results (P < 0.05). The incidence of vaginal delivery was more common when the CTG findings were normal, whereas all women with pathological CTG result had a cesarean delivery. CONCLUSION: Admission CTG was effective in identifying fetuses with a higher incidence of perinatal asphyxia. Neonatal outcome such as low birth weight, APGAR score, SCBU admission, and prolonged hospital admission was significantly associated with pathological CTG findings. In the absence of facilities for further investigations, prompt intervention for delivery should be ensured if admission CTG is pathological.


Résumé Contexte:La cardiotocographie d'admission (CTG), une procédure non invasive, est utilisée pour indiquer l'état d'oxygénation du fœtus lors de son admission en salle de travail.Objectif:Cette étude a évalué l'association entre les résultats du CTG à l'admission et l'issue néonatale dans un établissement de santé tertiaire.Matériels et méthodes:Une étude observationnelle prospective portant sur 206 femmes enceintes admises en salle de travail avec des grossesses vivantes uniques. Des informations sur les caractéristiques démographiques, les antécédents obstétricaux et médicaux, le traçage CTG à l'admission et les résultats néonatals ont été obtenues à l'aide d'un formulaire de collecte de données structuré. Les données ont été analysées à l'aide du logiciel SPSS version 20.0 avec le niveau de signification fixé à P <0,05.Résultats:Les résultats du CTG à l'admission étaient normaux chez 73,3 %, suspects chez 13,6 % et pathologiques chez 13,1 % des femmes. La survenue d'un faible poids à la naissance, d'une admission dans une unité de soins spéciaux pour bébés (SCBU), de nouveau-nés asphyxiés, de décès néonatals et d'une hospitalisation prolongée était significativement plus fréquente chez les personnes ayant des résultats CTG d'admission pathologiques par rapport aux résultats normaux et suspects (P < 0,05). L'incidence des accouchements par voie basse était plus fréquente lorsque les résultats du CTG étaient normaux, alors que toutes les femmes présentant un résultat pathologique du CTG avaient accouché par césarienne.Conclusion:L'admission CTG s'est avérée efficace pour identifier les fœtus présentant une incidence plus élevée d'asphyxie périnatale. Les résultats néonatals tels qu'un faible poids à la naissance, le score APGAR, l'admission au SCBU et l'hospitalisation prolongée étaient significativement associés aux résultats pathologiques du CTG. En l'absence de moyens permettant des investigations plus approfondies, une intervention rapide pour l'accouchement doit être assurée si l'admission du CTG est pathologique.


Assuntos
Asfixia Neonatal , Cardiotocografia , Resultado da Gravidez , Humanos , Feminino , Gravidez , Recém-Nascido , Estudos Prospectivos , Nigéria/epidemiologia , Adulto , Resultado da Gravidez/epidemiologia , Asfixia Neonatal/epidemiologia , Centros de Atenção Terciária , Recém-Nascido de Baixo Peso , Parto Obstétrico/métodos , Parto Obstétrico/estatística & dados numéricos , Cesárea/estatística & dados numéricos , Frequência Cardíaca Fetal , Admissão do Paciente/estatística & dados numéricos , Índice de Apgar , Adulto Jovem
8.
Sex Reprod Healthc ; 41: 101006, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38986340

RESUMO

OBJECTIVE: To describe intrapartum fetal monitoring methods used in all births in Norway in 2019-2020, assess adherence to national guidelines, investigate variation by women's risk status, and explore associations influencing monitoring practices. METHODS: A nationwide population-based study. We collected data about all pregnancies with a gestational age ≥ 22 weeks during 2019-2020 from the Medical Birth Registry of Norway. We used descriptive analyses, stratified for risk status, to examine fetal monitoring methods used in all deliveries. Univariable and multivariable logistic regression models were used to determine factors associated with monitoring with cardiotocography (CTG) in low-risk, straightforward births. RESULTS: In total, 14 285 (14%) deliveries were monitored with only intermittent auscultation (IA), 46214 (46%) with only CTG, and 33417 (34%) with IA and CTG combined. Four percent (2 067/50 533) of women with risk factors were monitored with IA only. Half (10589/21 282) of the low-risk women with straightforward births were monitored with CTG. Maternal and fetal characteristics, size of the birth unit and regional practices influenced use of CTG monitoring in this group. CONCLUSIONS: Most births are monitored with CTG only, or combined with IA. Half the women with low-risk pregnancies and straightforward births were monitored with CTG although national guidelines recommending IA.


Assuntos
Cardiotocografia , Monitorização Fetal , Fidelidade a Diretrizes , Humanos , Feminino , Noruega , Gravidez , Cardiotocografia/métodos , Cardiotocografia/normas , Adulto , Monitorização Fetal/métodos , Fidelidade a Diretrizes/estatística & dados numéricos , Sistema de Registros , Idade Gestacional , Parto Obstétrico/métodos , Parto Obstétrico/estatística & dados numéricos , Auscultação/métodos , Fatores de Risco , Frequência Cardíaca Fetal , Adulto Jovem
10.
Comput Biol Med ; 178: 108764, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38908358

RESUMO

BACKGROUND: The utilization of non-invasive techniques for fetal cardiac health surveillance is pivotal in evaluating fetal well-being throughout the gestational period. This process requires clean and interpretable fetal Electrocardiogram (fECG) signals. METHOD: The proposed work is the novel framework for the elicitation of fECG signals from abdominal ECG (aECG) recordings of the pregnant mother. The comprehensive approach encompasses pre-processing of the raw ECG signal, Blind Source Separation techniques (BSS), Decomposition techniques like Empirical Mode Decomposition (EMD), and its variants like Ensemble Empirical Mode Decomposition (EEMD), and Complete Ensemble Empirical Mode Decomposition with Additive Noise (CEEMDAN). The Robust Set Membership Affine Projection (RSMAP) Algorithm is deployed for the enhancement of the obtained fECG signal. RESULT: The results show significant improvements in the elicited fECG signal with a maximum Signal Noise Ratio (SNR) of 31.72 dB and correlation coefficient = 0.899, Maximum Heart Rate(MHR) obtained in the range of 108-142 bpm for all the records of abdominal ECG signals. The statistical test gave a p-value of 0.21 accepting the null hypothesis. The Abdominal and Direct Fetal Electrocardiogram Database (ABDFECGDB) from PhysioNet has been used for this analysis. CONCLUSION: The proposed framework demonstrates a robust and effective method for the elicitation and enhancement of fECG signals from the abdominal recordings.


Assuntos
Algoritmos , Eletrocardiografia , Processamento de Sinais Assistido por Computador , Humanos , Feminino , Eletrocardiografia/métodos , Gravidez , Monitorização Fetal/métodos , Abdome/fisiologia , Razão Sinal-Ruído , Frequência Cardíaca Fetal/fisiologia
11.
J Matern Fetal Neonatal Med ; 37(1): 2370398, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38937119

RESUMO

PURPOSE: To explore the effect of dural puncture epidural (DPE) block technique on fetal heart rate variability (HRV) during labor analgesia. METHODS: Sixty full-term primiparas who were in our hospital from April 2021 to October 2021 were selected and randomized into epidural analgesia (CEA) and dural puncture epidural analgesia (DPEA) groups (n = 30). After a successful epidural puncture, routine epidural catheter (EC) was performed in CEA group, and spinal anesthesia needle (as an EC) was used to puncture the dura mater to subarachnoid space in DPE group. Anesthetics were injected through EC. The time when the temperature sensation plane reached T10 (W1) and visual analog pain score (VAS), baseline heart rate score, amplitude variation score, cycle variation score, acceleration score, deceleration score, and total score of the first contraction after W1 were recorded. Apgar scores at 1 min, 5 min, and 10 min of neonates after delivery were recorded. RESULTS: The onset time of anesthesia in CEA group was significantly longer than that in DPEA group (p < .05). However, there are no significant differences in W1, VAS, baseline heart rate score, amplitude variation score, cycle variation score, acceleration score, deceleration score, and total score of the first contraction after W1 between the two groups (p > .05). Moreover, the Apgar scores at 1 min, 5 min and 10 min of neonates after delivery were not notably different between the two groups (p > .05). CONCLUSION: Compared with CEA, DPE block technique in labor analgesia relieves maternal pain without adverse effects on fetal HRV and newborns.


Assuntos
Analgesia Epidural , Analgesia Obstétrica , Frequência Cardíaca Fetal , Humanos , Feminino , Gravidez , Frequência Cardíaca Fetal/efeitos dos fármacos , Frequência Cardíaca Fetal/fisiologia , Analgesia Epidural/métodos , Analgesia Obstétrica/métodos , Analgesia Obstétrica/efeitos adversos , Adulto , Recém-Nascido , Índice de Apgar , Medição da Dor , Dura-Máter , Trabalho de Parto/fisiologia , Trabalho de Parto/efeitos dos fármacos
12.
J Clin Anesth ; 97: 111533, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38880002

RESUMO

STUDY OBJECTIVE: Spinal anesthesia often causes hypotension, with consequent risk to the fetus. The use of vasopressor agents has been highly recommended for the prevention of spinal anesthesia-induced hypotension during caesarean delivery. Many studies have shown that norepinephrine can provide more stable maternal hemodynamics than phenylephrine. We therefore tested the hypothesis that norepinephrine preserves fetal circulation better than phenylephrine when used to treat maternal hypotension consequent to spinal anesthesia. DESIGN: Prospective, randomized, double-blinded study. SETTING: Operating room. PATIENTS: We recruited 223 parturients with uncomplicated singleton pregnancies who were scheduled for elective caesarean section under combined spinal-epidural anesthesia. INTERVENTIONS: The patients received prophylactic intravenous infusion of either 0.08 µg/kg/min norepinephrine or 0.5 µg/kg/min phenylephrine for prevention of spinal anesthesia-induced hypotension. MEASUREMENTS: Changes in fetal heart rate and fetal cardiac output before and after spinal anesthesia were measured using noninvasive Doppler ultrasound. MAIN RESULTS: 90 subjects who received norepinephrine infusion and 93 subjects who received phenylephrine infusion were ultimately analyzed in the present study. The effects of norepinephrine and phenylephrine on the change of fetal heart rate and fetal cardiac output at 3 and 6 min after spinal block were similar. Although there was a statistically significant decrease in fetal cardiac output at 6 min after subarachnoid block initiation in both the norepinephrine group (mean difference 0.02 L/min; 95% CI, 0-0.04 L/min; P = 0.03) and the phenylephrine group (mean difference 0.02 L/min; 95% CI, 0-0.04 L/min; P = 0.02), it remained within the normal range. CONCLUSIONS: Prophylactic infusion of comparable doses of phenylephrine or norepinephrine has similar effects on fetal heart rate and cardiac output changes after spinal anesthesia. Neither phenylephrine nor norepinephrine has meaningful detrimental effects on fetal circulation or neonatal outcomes.


Assuntos
Anestesia Obstétrica , Raquianestesia , Débito Cardíaco , Cesárea , Frequência Cardíaca Fetal , Hipotensão , Norepinefrina , Fenilefrina , Vasoconstritores , Humanos , Fenilefrina/administração & dosagem , Fenilefrina/efeitos adversos , Feminino , Método Duplo-Cego , Cesárea/efeitos adversos , Gravidez , Raquianestesia/efeitos adversos , Hipotensão/prevenção & controle , Hipotensão/etiologia , Norepinefrina/administração & dosagem , Norepinefrina/efeitos adversos , Adulto , Vasoconstritores/administração & dosagem , Estudos Prospectivos , Frequência Cardíaca Fetal/efeitos dos fármacos , Anestesia Obstétrica/efeitos adversos , Anestesia Obstétrica/métodos , Débito Cardíaco/efeitos dos fármacos , Anestesia Epidural/efeitos adversos , Anestesia Epidural/métodos , Infusões Intravenosas
13.
Prenat Diagn ; 44(9): 1088-1097, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38877305

RESUMO

OBJECTIVE: To compare the occurrence of fetal bradycardia in open versus fetoscopic fetal spina bifida surgery. METHODS: This is a single-institution retrospective cohort study of patients undergoing open (n = 25) or fetoscopic (n = 26) spina bifida repair between 2017 and 2022. From October 2017 to June 2020, spina bifida repairs were performed via an open classical hysterotomy, and from November 2020 to June 2022 fetoscopic repairs were performed following transition to this technique. Fetal heart rate (FHR) in beats per minute (bpm) was recorded via echocardiography every 15 min during the procedure. Cohort characteristics, fetal bradycardia and maternal physiologic parameters were compared between the groups. RESULTS: Fetuses undergoing an open repair more frequently developed bradycardia defined as <110 bpm (32% vs. 3.8%, p = 0.008), and a trend was observed for FHR decreases more than 25 bpm from baseline (20% vs. 3.8%, p = 0.073). Profound bradycardia less than 80 bpm was rare, occurring in only three operations (two in open, one in fetoscopic repair) with two fetuses (one in each group) requiring emergency cesarean delivery. CONCLUSION: When compared to open fetal surgery, fetal bradycardia occurred less frequently in fetoscopic surgery despite a significantly greater anesthetic exposure and the use of the intraamniotic carbon dioxide insufflation.


Assuntos
Bradicardia , Fetoscopia , Disrafismo Espinal , Humanos , Fetoscopia/métodos , Fetoscopia/efeitos adversos , Bradicardia/etiologia , Bradicardia/epidemiologia , Feminino , Gravidez , Estudos Retrospectivos , Disrafismo Espinal/cirurgia , Disrafismo Espinal/complicações , Adulto , Frequência Cardíaca Fetal , Histerotomia/métodos , Histerotomia/efeitos adversos , Doenças Fetais/cirurgia
14.
Sci Rep ; 14(1): 12615, 2024 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-38824217

RESUMO

Standard clinical practice to assess fetal well-being during labour utilises monitoring of the fetal heart rate (FHR) using cardiotocography. However, visual evaluation of FHR signals can result in subjective interpretations leading to inter and intra-observer disagreement. Therefore, recent studies have proposed deep-learning-based methods to interpret FHR signals and detect fetal compromise. These methods have typically focused on evaluating fixed-length FHR segments at the conclusion of labour, leaving little time for clinicians to intervene. In this study, we propose a novel FHR evaluation method using an input length invariant deep learning model (FHR-LINet) to progressively evaluate FHR as labour progresses and achieve rapid detection of fetal compromise. Using our FHR-LINet model, we obtained approximately 25% reduction in the time taken to detect fetal compromise compared to the state-of-the-art multimodal convolutional neural network while achieving 27.5%, 45.0%, 56.5% and 65.0% mean true positive rate at 5%, 10%, 15% and 20% false positive rate respectively. A diagnostic system based on our approach could potentially enable earlier intervention for fetal compromise and improve clinical outcomes.


Assuntos
Cardiotocografia , Aprendizado Profundo , Frequência Cardíaca Fetal , Frequência Cardíaca Fetal/fisiologia , Humanos , Gravidez , Feminino , Cardiotocografia/métodos , Redes Neurais de Computação , Monitorização Fetal/métodos , Processamento de Sinais Assistido por Computador , Feto
15.
Neurotoxicol Teratol ; 104: 107368, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38906389

RESUMO

BACKGROUND: Buprenorphine-naloxone treatment may confer substantial benefits for the treatment of opioid use disorder (OUD) during pregnancy including lower risk for overdose/death, less diversion potential and reduced use of other substances. Treatment may also result in less severe Neonatal Abstinence Syndrome (NAS), but little is known about the effects of this medication on fetal neurodevelopment. METHODS: The purpose of the current study is to evaluate neurobehaviors among fetuses exposed to buprenorphine-naloxone at four time points over the second and third trimesters of gestation in pregnant women with OUD on buprenorphine-naloxone therapy. Sixty minutes of continuous fetal monitoring via fetal actocardiograph with a single wide array abdominal transducer took place at times of peak and trough buprenorphine-naloxone levels in 24 pregnant women. Data collection, which included measures of fetal heart rate and motor activity, was conducted between 24 and 36 weeks gestation, with the majority (84.6%) monitored at two or more gestational ages. Medication dose and other substance use was monitored throughout the study and infant NAS severity was assessed. RESULTS: Fetal heart rate (FHR), FHR variability, accelerations in FHR, and motor activity were suppressed when buprenorphine-naloxone levels were at pharmacologic peak as compared to trough concentrations at 36 weeks, but not earlier in gestation. Maternal medication dose was unrelated to infant NAS severity. CONCLUSIONS: Conclusions: There were evident subclinical fetal neurophysiological responses at times of peak maternal buprenorphine/naloxone levels in later gestation, similar to those previously described for buprenorphine only. Further studies evaluating the effects of these changes in fetal neurobehaviors on the longer-term infant development are needed.


Assuntos
Combinação Buprenorfina e Naloxona , Frequência Cardíaca Fetal , Transtornos Relacionados ao Uso de Opioides , Humanos , Feminino , Gravidez , Adulto , Transtornos Relacionados ao Uso de Opioides/tratamento farmacológico , Frequência Cardíaca Fetal/efeitos dos fármacos , Recém-Nascido , Adulto Jovem , Síndrome de Abstinência Neonatal , Tratamento de Substituição de Opiáceos , Complicações na Gravidez/tratamento farmacológico , Efeitos Tardios da Exposição Pré-Natal/induzido quimicamente , Buprenorfina/efeitos adversos , Terceiro Trimestre da Gravidez , Feto/efeitos dos fármacos , Antagonistas de Entorpecentes
16.
Arch Gynecol Obstet ; 310(1): 337-344, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38829389

RESUMO

PURPOSE: To compare perinatal outcomes between active and routine management in true knot of the umbilical cord (TKUC). METHODS: A retrospective study of singletons born beyond 22 6/7 weeks with TKUC. Active management included weekly fetal heart rate monitoring(FHRM) ≥ 30 weeks and labor induction at 36-37 weeks. Outcomes in active and routine management were compared, including composite asphyxia-related adverse outcome, fetal death, labor induction, Cesarean section (CS) or Instrumental delivery due to non-reassuring fetal heart rate (NRFHR), Apgar5 score < 7, cord Ph < 7, neonatal intensive care unit (NICU) admission and more. RESULTS: The Active (n = 59) and Routine (n = 1091) Management groups demonstrated similar rates of composite asphyxia-related adverse outcome (16.9% vs 16.8%, p = 0.97). Active Management resulted in higher rates of labor induction < 37 weeks (22% vs 1.7%, p < 0.001), CS (37.3% vs 19.2%, p = 0.003) and NICU admissions (13.6% vs 3%, p < 0.001). Fetal death occurred exclusively in the Routine Management group (1.8% vs 0%, p = 0.6). CONCLUSION: Compared with routine management, weekly FHRM and labor induction between 36 and 37 weeks in TKUC do not appear to reduce neonatal asphyxia. In its current form, active management is associated with higher rates of CS, induced prematurity and NICU admissions. Labor induction before 37 weeks should be avoided.


Assuntos
Cesárea , Frequência Cardíaca Fetal , Trabalho de Parto Induzido , Cordão Umbilical , Humanos , Estudos Retrospectivos , Feminino , Gravidez , Cordão Umbilical/cirurgia , Recém-Nascido , Adulto , Trabalho de Parto Induzido/métodos , Cesárea/estatística & dados numéricos , Índice de Apgar , Unidades de Terapia Intensiva Neonatal , Morte Fetal , Resultado da Gravidez , Asfixia Neonatal/terapia
17.
J Ultrasound Med ; 43(9): 1637-1643, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38760971

RESUMO

OBJECTIVES: To assess first-trimester prognosis when an early pregnancy sonogram demonstrates a normal embryonic heart rate and to determine how a number of risk factors affect prognosis. METHODS: Our study population consisted of 6597 first-trimester scans with gestational age (GA) ≤ 7.0 weeks (all with crown-rump length [CRL] <10 mm), normal embryonic heart, and known first-trimester outcome. We recorded GA; CRL; heart rate; first-trimester outcome; maternal age; presence, absence, and size of subchorionic hematoma; presence or absence of vaginal bleeding; and presence, absence, and size of uterine fibroids. We assessed first-trimester outcome in the study population and subsets based on the above data. RESULTS: First-trimester outcome was successful in 6030 of the 6597 cases (91.4%). The prognosis was somewhat worse with each of the following risk factors: maternal age ≥35 years, large subchorionic hematoma, and large or multiple uterine fibroids (P < .02, chi-squared or Cochran's test for trend, for all of these items). The rate of successful outcome was in the range of 83-88% with each of these risk factors and 93.8% in the absence of any of these factors. CONCLUSIONS: The presence of a normal embryonic heart rate on an early first-trimester sonogram is a reassuring finding, indicating a likelihood of good first-trimester outcome of at least 83% even in the presence of risk factors, and of over 90% in the absence of such factors.


Assuntos
Frequência Cardíaca Fetal , Primeiro Trimestre da Gravidez , Ultrassonografia Pré-Natal , Humanos , Feminino , Gravidez , Ultrassonografia Pré-Natal/métodos , Fatores de Risco , Adulto , Frequência Cardíaca Fetal/fisiologia , Prognóstico , Resultado da Gravidez , Estudos Retrospectivos
20.
Pan Afr Med J ; 47: 83, 2024.
Artigo em Francês | MEDLINE | ID: mdl-38737224

RESUMO

Uterine rupture is a life-threatening obstetric complication. The purpose of this study was to investigate the epidemiological features, maternal and foetal prognosis and different treatment options for uterine rupture in healthy and scarred uteri. We conducted a retrospective monocentric descriptive and analytical study of 60 cases of uterine rupture collected in the Department of Gynaecology-Obstetrics of the Center of Maternity and Neonatology, Monastir, from 2017 to 2021. Patients were classified according to the presence or absence of a uterine scar. Sixty patients were enrolled in the study. The majority of cases of rupture occurred in patients with scarred uterus (n=55). The most common clinical sign was abnormal foetal heart rate. No maternal deaths were recorded and perinatal mortality rate was 11%. Mean BMI, fetal macrosomia rate and mean parity were significantly higher in the healthy uterus group than in the scarred uterus group (p=0.033, 0.018, and 0.013, respectively). The maternal complications studied (post-partum haemorrhage, hysterectomy, blood transfusion, prolonged hospitalisation) were significantly more frequent in patients with unscarred uterine rupture (p=0.039; p=0.032; p=0.009; p=0.025 respectively). Uterine rupture is a life-threatening obstetrical event for the foetus and the mother. Fetal heart rate abnormality is the most common sign associated with uterine rupture. Management is based on conservative treatment in most cases. Patients with scarred uterus have a better prognosis.


Assuntos
Hemorragia Pós-Parto , Ruptura Uterina , Humanos , Feminino , Tunísia/epidemiologia , Estudos Retrospectivos , Ruptura Uterina/epidemiologia , Ruptura Uterina/etiologia , Adulto , Gravidez , Hemorragia Pós-Parto/epidemiologia , Hemorragia Pós-Parto/terapia , Hemorragia Pós-Parto/etiologia , Adulto Jovem , Cicatriz , Prognóstico , Histerectomia/estatística & dados numéricos , Mortalidade Perinatal , Macrossomia Fetal/epidemiologia , Recém-Nascido , Frequência Cardíaca Fetal , Transfusão de Sangue/estatística & dados numéricos , Tempo de Internação/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...