Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21.697
Filtrar
1.
J Oleo Sci ; 73(6): 857-863, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38825539

RESUMO

The hybridization of lipids with graphene is expected to produce a promising, novel biomaterial. However, there are limited examples of the covalent introduction of lipid molecules, especially the immobilization of lipid molecules, onto graphene on a substrate. Therefore, we investigated the hybridization of a silane coupling agent having phospholipid moieties with graphene oxide on substrates prepared by photo-oxidation using chlorine dioxide. Three silane coupling agents with different carbon chain lengths (C4, C6, C8) were synthesized and phospholipid molecules were introduced onto graphene on a substrate. Phospholipid-immobilized graphene on a grid for TEM (transmission electron microscope) was used for EM analysis of proteins (glyceraldehyde 3-phosphate dehydrogenase and ß-galactosidase), enabling the observation of sufficient particles compared to the conventional graphene grid.


Assuntos
Grafite , Fosfolipídeos , Silanos , Grafite/química , Fosfolipídeos/química , Silanos/química , beta-Galactosidase/metabolismo , Microscopia Eletrônica de Transmissão , Oxirredução , Materiais Biocompatíveis/química , Materiais Biocompatíveis/síntese química
2.
Carbohydr Polym ; 339: 122232, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38823905

RESUMO

In this study, new types of hybrid double-network (DN) hydrogels composed of polyvinyl alcohol (PVA), chitosan (CH), and sodium alginate (SA) are introduced, with the hypothesis that this combination and incorporating multi-walled carbon nanotubes (MWCNTs) and graphene nanoplatelets (GNPs) will enhance osteogenetic differentiation and the structural and mechanical properties of scaffolds for bone tissue engineering applications. Initially, the impact of varying mass ratios of the PVA/CH/SA mixture on mechanical properties, swelling ratio, and degradability was examined. Based on this investigation, a mass ratio of 4:6:6 was determined to be optimal. At this ratio, the hydrogel demonstrated a Young's modulus of 47.5 ± 5 kPa, a swelling ratio of 680 ± 6 % after 3 h, and a degradation rate of 46.5 ± 5 % after 40 days. In the next phase, following the determination of the optimal mass ratio, CNTs and GNPs were incorporated into the 4:6:6 composite resulting in a significant enhancement in the electrical conductivity and stiffness of the scaffolds. The introduction of CNTs led to a notable increase of 36 % in the viability of MG63 osteoblast cells. Additionally, the inhibition zone test revealed that GNPs and CNTs increased the diameter of the inhibition zone by 49.6 % and 52.6 %, respectively.


Assuntos
Alginatos , Regeneração Óssea , Quitosana , Hidrogéis , Álcool de Polivinil , Engenharia Tecidual , Alicerces Teciduais , Quitosana/química , Alginatos/química , Alginatos/farmacologia , Álcool de Polivinil/química , Alicerces Teciduais/química , Humanos , Regeneração Óssea/efeitos dos fármacos , Hidrogéis/química , Hidrogéis/farmacologia , Engenharia Tecidual/métodos , Nanotubos de Carbono/química , Osteoblastos/efeitos dos fármacos , Osteoblastos/citologia , Grafite/química , Grafite/farmacologia , Materiais Biomiméticos/química , Materiais Biomiméticos/farmacologia , Sobrevivência Celular/efeitos dos fármacos , Linhagem Celular
3.
Mol Biol Rep ; 51(1): 702, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38822942

RESUMO

BACKGROUND: The development of cost-effective, simple, environment-friendly biographene is an area of interest. To accomplish environmentally safe, benign culturing that has advantages over other methods to reduce the graphene oxide (GO), extracellular metabolites from actinobacteria associated with mushrooms were used for the first time. METHODS: Bactericidal effect of GO against methicillin-resistant Staphylococcus aureus, antioxidant activity, and hydroxyapatite-like bone layer formation, gene expression analysis and appropriate biodegradation of the microbe-mediated synthesis of graphene was studied. RESULTS: Isolated extracellular contents Streptomyces achromogenes sub sp rubradiris reduced nano-GO to graphene (rGO), which was further examined by spectrometry and suggested an efficient conversion and significant reduction in the intensity of all oxygen-containing moieties and shifted crystalline peaks. Electron microscopic results also suggested the reduction of GO layer. In addition, absence of significant toxicity in MG-63 cell line, intentional free radical scavenging prowess, liver and kidney histopathology, and Wistar rat bone regeneration through modulation of OPG/RANKL/RUNX2/ALP pathways show the feasibility of the prepared nano GO. CONCLUSIONS: The study demonstrates the successful synthesis of biographene from actinobacterial extracellular metabolites, its potential biomedical applications, and its promising role in addressing health and environmental concerns.


Assuntos
Regeneração Óssea , Grafite , Osteoprotegerina , Ligante RANK , Ratos Wistar , Grafite/farmacologia , Animais , Regeneração Óssea/efeitos dos fármacos , Ratos , Ligante RANK/metabolismo , Osteoprotegerina/metabolismo , Humanos , Materiais Biocompatíveis/farmacologia , Subunidade alfa 1 de Fator de Ligação ao Core/metabolismo , Subunidade alfa 1 de Fator de Ligação ao Core/genética , Actinobacteria/metabolismo , Antibacterianos/farmacologia , Antioxidantes/metabolismo , Antioxidantes/farmacologia , Transdução de Sinais/efeitos dos fármacos
4.
Anal Chim Acta ; 1312: 342686, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38834256

RESUMO

BACKGROUND: Fentanyl and its derivatives are a type of potent opioid analgesics, with the characteristics of diverse structure, high toxicity, extremely low content, and high fatality rate. Currently, they have become one of the most serious problems in international drug abuse control due to their extensive use in drug production and use. Therefore, the development of a rapid, sensitive, and accurate method for detecting trace fentanyl is of great significance. In this study, in view of its complex structure and trace concentration, a new molecular imprinting electrochemical sensor was developed through molecular simulations followed by experimental validation to detect trace fentanyl. RESULTS: The process consisted of first obtaining the optimal functional monomer and its molar ratio through molecular simulations. The recognition sites of fentanyl-imprinted polymers were predicted to guide the synthesis of imprinted membranes with precision approach to ensure an efficient and accurate reaction process. Reduced graphene oxide (ErGO) was then deposited on glassy carbon electrode surface by electrochemical reduction to yield large numbers of active sites suitable for catalyzing reactions of fentanyl piperidine for promoted efficient electron transfer and amplified sensitivity of the sensor. Accordingly, fentanyl molecularly imprinted film was formed through one-step electropolymerization to yield greatly improved sensing selectivity due to the specific recognition of molecularly imprinted polymer. Under optimal experimental conditions, the fentanyl sensor showed an extended detection range of 3.84 × 10-9 mol L-1-1.72 × 10-6 mol L-1 and a detection limit of 1.28 × 10-9 mol L-1. SIGNIFICANCE: A distinctive feature of this sensor is its molecularly imprinted polymerized membrane, which offers excellent specific recognition, thereby boosting the sensor's selectivity. Throughout the sensor's development process, molecular simulations were employed to steer the synthesis of molecularly imprinted polymers and predict the recognition sites of fentanyl-imprinted polymers. The experimental outcomes proved to align with the simulation data. The final sensor exhibited outstanding selectivity, repeatability, stability, and high sensitivity. The sensor was effectively used to reliably track fentanyl in human serum samples, with acceptable analytical reliability, suggesting its potential for practical applications.


Assuntos
Técnicas Eletroquímicas , Fentanila , Impressão Molecular , Fentanila/análise , Fentanila/sangue , Fentanila/química , Polímeros Molecularmente Impressos/química , Eletrodos , Limite de Detecção , Grafite/química , Simulação de Dinâmica Molecular , Analgésicos Opioides/sangue , Analgésicos Opioides/análise , Analgésicos Opioides/química , Humanos
5.
Mikrochim Acta ; 191(7): 373, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38842697

RESUMO

The design of surface plasmon resonance (SPR) sensors has been greatly enhanced in recent years by the advancements in the production and integration of nanostructures, leading to more compact and efficient devices. There have been reports of novel SPR sensors having distinct nanostructures, either as signal amplification tags like gold nanoparticles (AuNPs) or as sensing substrate-like two-dimensional (2D) materials including graphene, transition metal dichalcogenides (TMDCs), MXene, black phosphorus (BP), metal-organic frameworks (MOFs), and antimonene. Such 2D-based SPR biosensors offer advantages over conventional sensors due to significant increases in their sensitivity with a good figure of merit and limit of detection (LOD). Due to their atomically thin structure, improved sensitivity, and sophisticated functionalization capabilities, 2D materials can open up new possibilities in the field of healthcare, particularly in point-of-care diagnostics, environmental and food monitoring, homeland security protection, clinical diagnosis and treatment, and flexible or transient bioelectronics. The present study articulates an in-depth analysis of the most recent developments in 2D material-based SPR sensor technology. Moreover, in-depth research of 2D materials, their integration with optoelectronic technology for a new sensing platform, and the predicted and experimental outcomes of various excitation approaches are highlighted, along with the principles of SPR biosensors. Furthermore, the review projects the potential prospects and future trends of these emerging materials-based SPR biosensors to advance in clinical diagnosis, healthcare biochemical, and biological applications.


Assuntos
Ressonância de Plasmônio de Superfície , Ressonância de Plasmônio de Superfície/métodos , Técnicas Biossensoriais/métodos , Grafite/química , Nanopartículas Metálicas/química , Ouro/química , Humanos , Estruturas Metalorgânicas/química , Limite de Detecção , Nanoestruturas/química , Fósforo/química
6.
Mikrochim Acta ; 191(6): 362, 2024 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-38822867

RESUMO

Rapid and accurate in situ determination of dopamine is of great significance in the study of neurological diseases. In this work, poly (3,4-ethylenedioxythiophene): poly (styrenesulfonic acid) (PEDOT: PSS)/graphene oxide (GO) fibers were fabricated by an effective method based on microfluidic wet spinning technology. The composite microfibers with stratified and dense arrangement were continuously prepared by injecting PEDOT: PSS and GO dispersion solutions into a microfluidic chip. PEDOT: PSS/GO fiber microelectrodes with high electrochemical activity and enhanced electrochemical oxidation activity of dopamine were constructed by controlling the structure composition of the microfibers with varying flow rate. The fabricated fiber microelectrode had a low detection limit (4.56 nM) and wide detection range (0.01-8.0 µM) for dopamine detection with excellent stability, repeatability, and reproducibility. In addition, the PEDOT: PSS/GO fiber microelectrode prepared was successfully used for the detection of dopamine in human serum and PC12 cells. The strategy for the fabrication of multi-component fiber microelectrodes is a new and effective approach for monitoring the intercellular neurotransmitter dopamine and has high potential as an implantable neural microelectrode.


Assuntos
Dopamina , Grafite , Microeletrodos , Poliestirenos , Células PC12 , Dopamina/sangue , Humanos , Ratos , Animais , Poliestirenos/química , Grafite/química , Limite de Detecção , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Compostos Bicíclicos Heterocíclicos com Pontes/química , Tiofenos/química , Dispositivos Lab-On-A-Chip , Polímeros
7.
Mikrochim Acta ; 191(6): 361, 2024 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-38822891

RESUMO

A one-shot CO2 laser-based strategy to generate conductive reduced graphene oxide (rGO) decorated with nanoceria (nCe) is proposed. The 2D/0D rGO-nCe films, integrated as catalytic sensing layers in paper-based sensors, were employed for on-site monitoring of indoor fogging treatments against Listeria monocytogenes (Lm), a ubiquitous pathogenic bacterium. The rGO-nCe laser-assisted synthesis was optimized to preserve the rGO film morphological and electron-transfer features and simultaneously integrate catalytic nCe. The films were characterized by microscopical (SEM), spectroscopical (EDX, Raman, and FTIR), and electrochemical techniques. The most performing film was integrated into a nitrocellulose substrate, and the complete sensor was assembled via a combination of xurography and stencil printing. The rGO-nCe sensor's catalytic activity was proved toward the detection of H2O2, obtaining sensitive determination (LOD = 0.3 µM) and an extended linear range (0.5-1500 µM). Eventually, the rGO-nCe sensor was challenged for the real-time continuous monitoring of hydrogen peroxide aerosol during no-touch fogging treatment conducted following the EU's recommendation for biocidal product use. Treatment effectiveness was proved toward three Lm strains characterized by different origins, i.e., type strain ATCC 7644, clinical strain 338, and food strain 641/6II. The sensor allows for discrimination and quantification treatments at different environmental biocidal amounts and fogging times, and correlates with the microbiological inhibition, promoting the proposed sensor as a useful tool to modulate and monitor no-touch treatments.


Assuntos
Desinfecção , Grafite , Peróxido de Hidrogênio , Lasers , Listeria monocytogenes , Papel , Grafite/química , Peróxido de Hidrogênio/química , Listeria monocytogenes/efeitos dos fármacos , Listeria monocytogenes/isolamento & purificação , Desinfecção/métodos , Cério/química , Limite de Detecção , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Catálise
8.
Anal Chim Acta ; 1306: 342581, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38692785

RESUMO

Cancer detection is still a major challenge in public health. Identification of oncogene is the first step toward solving this problem. Studies have revealed that various cancers are associated with miRNA expression. Therefore, the sensitive detection of miRNA is substantially important to solve the cancer problem. In this study, let-7a, a representative substance of miRNA, was selected as the detection target. With the assistance of magnetic beads commonly used in biosensors and self-synthesized graphene oxide materials, specificity and sensitivity detection of the target gene let-7a were achieved via protease-free signal amplification. The limit of detection (LOD) was as low as 15.015pM. The fluorescence signal intensity showed a good linear relationship with the logarithm of let-7a concentration. The biosensor could also detect let-7a in complex human serum samples. Overall, this fluorescent biosensor is not only simple to operate, but also strongly specificity to detect let-7a. Therefore, it has substantial potential for application in the early diagnosis of clinical medicine and biological research.


Assuntos
Técnicas Biossensoriais , Grafite , Limite de Detecção , MicroRNAs , Técnicas Biossensoriais/métodos , Humanos , Grafite/química , MicroRNAs/análise , MicroRNAs/sangue , Espectrometria de Fluorescência , Corantes Fluorescentes/química , Neoplasias/diagnóstico , Neoplasias/sangue
9.
Luminescence ; 39(5): e4753, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38698700

RESUMO

A simple and environmentally friendly method was developed for smart and efficient waterborne polyurethane (PUR) paint. Sugarcane bagasse was recycled into reduced graphene oxide nanosheets (rGONSs). Both lanthanide-doped aluminate nanoparticles (LAN; photoluminescent agent, 7-9 nm) and rGONSs (reinforcement agent) were integrated into a waterborne polyurethane to produce a novel photoluminescent, hydrophobic, and anticorrosive nanocomposite coating. Using ferrocene-based oxidation under masked circumstances, graphene oxide nanosheets were produced from sugarcane bagasse. The oxidized semicarbazide (SCB) nanostructures were integrated into polyurethane coatings as a drying, anticorrosion, and crosslinking agent. Polyurethane coatings with varying amounts of phosphor pigment were prepared and subsequently applied to mild steel. The produced paints (LAN/rGONSs@PUR) were tested for their hydrophobicity, hardness, and scratch resistance. Commission Internationale de l'éclairage (CIE) Laboratory parameters and photoluminescence analysis established the opacity and colourimetric properties of the nanocomposite coatings. When excited at 365 nm, the luminescent transparent paints emitted a strong greenish light at 517 nm. The anticorrosion characteristics of the coated steel were investigated. The phosphor-containing (11% w/w) polyurethane coatings displayed the most pronounced anticorrosion capability and long-persistent luminosity. The prepared waterborne polyurethane paints were very photostable and durable.


Assuntos
Grafite , Interações Hidrofóbicas e Hidrofílicas , Nanocompostos , Pintura , Poliuretanos , Poliuretanos/química , Grafite/química , Nanocompostos/química , Luminescência , Corrosão , Química Verde
10.
Sci Adv ; 10(18): eadl5067, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38701201

RESUMO

Airborne pathogens retain prolonged infectious activity once attached to the indoor environment, posing a pervasive threat to public health. Conventional air filters suffer from ineffective inactivation of the physics-separated microorganisms, and the chemical-based antimicrobial materials face challenges of poor stability/efficiency and inefficient viral inactivation. We, therefore, developed a rapid, reliable antimicrobial method against the attached indoor bacteria/viruses using a large-scale tunneling charge-motivated disinfection device fabricated by directly dispersing monolayer graphene on insulators. Free charges can be stably immobilized under the monolayer graphene through the tunneling effect. The stored charges can motivate continuous electron loss of attached microorganisms for accelerated disinfection, overcoming the diffusion limitation of chemical disinfectants. Complete (>99.99%) and broad-spectrum disinfection was achieved <1 min of attachment to the scaled-up device (25 square centimeters), reliably for 72 hours at high temperature (60°C) and humidity (90%). This method can be readily applied to high-touch surfaces in indoor environments for pathogen control.


Assuntos
Desinfecção , Eletrônica , Grafite , Desinfecção/métodos , Eletrônica/métodos , Grafite/química , Viabilidade Microbiana , Bactérias
11.
Mikrochim Acta ; 191(6): 301, 2024 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-38709350

RESUMO

In the era of wearable electronic devices, which are quite popular nowadays, our research is focused on flexible as well as stretchable strain sensors, which are gaining humongous popularity because of recent advances in nanocomposites and their microstructures. Sensors that are stretchable and flexible based on graphene can be a prospective 'gateway' over the considerable biomedical speciality. The scientific community still faces a great problem in developing versatile and user-friendly graphene-based wearable strain sensors that satisfy the prerequisites of susceptible, ample range of sensing, and recoverable structural deformations. In this paper, we report the fabrication, development, detailed experimental analysis and electronic interfacing of a robust but simple PDMS/graphene/PDMS (PGP) multilayer strain sensor by drop casting conductive graphene ink as the sensing material onto a PDMS substrate. Electrochemical exfoliation of graphite leads to the production of abundant, fast and economical graphene. The PGP sensor selective to strain has a broad strain range of ⁓60%, with a maximum gauge factor of 850, detection of human physiological motion and personalized health monitoring, and the versatility to detect stretching with great sensitivity, recovery and repeatability. Additionally, recoverable structural deformation is demonstrated by the PGP strain sensors, and the sensor response is quite rapid for various ranges of frequency disturbances. The structural designation of graphene's overlap and crack structure is responsible for the resistance variations that give rise to the remarkable strain detection properties of this sensor. The comprehensive detection of resistance change resulting from different human body joints and physiological movements demonstrates that the PGP strain sensor is an effective choice for advanced biomedical and therapeutic electronic device utility.


Assuntos
Dimetilpolisiloxanos , Grafite , Dispositivos Eletrônicos Vestíveis , Grafite/química , Humanos , Dimetilpolisiloxanos/química , Movimento
12.
Sci Rep ; 14(1): 10293, 2024 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-38704412

RESUMO

In this study, a sensitive and selective fluorescent chemosensor was developed for the determination of pirimicarb pesticide by adopting the surface molecular imprinting approach. The magnetic molecularly imprinted polymer (MIP) nanocomposite was prepared using pirimicarb as the template molecule, CuFe2O4 nanoparticles, and graphene quantum dots as a fluorophore (MIP-CuFe2O4/GQDs). It was then characterized using X-ray diffraction (XRD) technique, Fourier transforms infrared (FT-IR) spectroscopy, scanning electron microscope (SEM), and transmission electron microscopy (TEM). The response surface methodology (RSM) was also employed to optimize and estimate the effective parameters of pirimicarb adsorption by this polymer. According to the experimental results, the average particle size and imprinting factor (IF) of this polymer are 53.61 nm and 2.48, respectively. Moreover, this polymer has an excellent ability to adsorb pirimicarb with a removal percentage of 99.92 at pH = 7.54, initial pirimicarb concentration = 10.17 mg/L, polymer dosage = 840 mg/L, and contact time = 6.15 min. The detection of pirimicarb was performed by fluorescence spectroscopy at a concentration range of 0-50 mg/L, and a sensitivity of 15.808 a.u/mg and a limit of detection of 1.79 mg/L were obtained. Real samples with RSD less than 2 were measured using this chemosensor. Besides, the proposed chemosensor demonstrated remarkable selectivity by checking some other insecticides with similar and different molecular structures to pirimicarb, such as diazinon, deltamethrin, and chlorpyrifos.


Assuntos
Praguicidas , Pirimidinas , Praguicidas/análise , Carbamatos/análise , Carbamatos/química , Pontos Quânticos/química , Polímeros Molecularmente Impressos/química , Polímeros/química , Espectrometria de Fluorescência/métodos , Grafite/química , Impressão Molecular/métodos , Adsorção , Limite de Detecção , Espectroscopia de Infravermelho com Transformada de Fourier , Nanocompostos/química , Nanocompostos/ultraestrutura
13.
Nan Fang Yi Ke Da Xue Xue Bao ; 44(4): 617-626, 2024 Apr 20.
Artigo em Chinês | MEDLINE | ID: mdl-38708493

RESUMO

OBJECTIVE: To investigate immunogenic and toxic effects of graphene oxide (GO) nanoparticles in mouse skeletal muscles and in human blood in vitro. METHODS: GO nanoparticles prepared using a probe sonicator were supended in deionized H2O or PBS, and particle size and surface charge of the nanoparticles were measured with dynamic light scattering (DLS). Different concentrations (0.5, 1.0 and 2.0 mg/mL) of GO suspension or PBS were injected at multiple sites in the gastrocnemius muscle (GN) of C57BL/6 mice, and inflammatory response and immune cell infiltrations were detected with HE and immunofluorescence staining. We also examined the effects of GO nanoparticles on human red blood cell (RBC) morphology, hemolysis and blood coagulation using scanning electron microscope (SEM), spectrophotometry, and thromboelastography (TEG). RESULTS: GO nanoparticles suspended in PBS exhibited better colloidal dispersity, stability and surface charge effects than those in deionized H2O. In mouse GNs, injection of GO suspensions dose- and time-dependently resulted in sustained muscular inflammation and myofiber degeneration at the injection sites, which lasted till 8 weeks after the injection; immunofluorescence staining revealed obvious infiltration of monocytes, macrophages, dendritic cells and CD4+ T cells around the injection sites in mouse GNs. In human RBCs, incubation with GO suspensions at 0.2, 2.0 and 20 mg/mL, but not at 0.002 or 0.02 mg/mL, caused significant alterations of cell morphology and hemolysis. TEG analysis showed significant abnormalities of blood coagulation parameters following treatment with high concentrations of GO. CONCLUSION: GO nanoparticles can induce sustained inflammatory and immunological responses in mouse GNs and cause RBC hemolysis and blood coagulation impairment, suggesting its muscular toxicity and hematotoxicity at high concentrations.


Assuntos
Eritrócitos , Grafite , Hemólise , Camundongos Endogâmicos C57BL , Músculo Esquelético , Nanopartículas , Animais , Grafite/toxicidade , Grafite/química , Camundongos , Eritrócitos/efeitos dos fármacos , Humanos , Músculo Esquelético/efeitos dos fármacos , Hemólise/efeitos dos fármacos , Tamanho da Partícula , Coagulação Sanguínea/efeitos dos fármacos
14.
Mikrochim Acta ; 191(6): 313, 2024 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-38717608

RESUMO

Copper levels in biological fluids are associated with Wilson's, Alzheimer's, Menke's, and Parkinson's diseases, making them good biochemical markers for these diseases. This study introduces a miniaturized screen-printed electrode (SPE) for the potentiometric determination of copper(II) in some biological fluids. Manganese(III) oxide nanoparticles (Mn2O3-NPs), dispersed in Nafion, are drop-casted onto a graphite/PET substrate, serving as the ion-to-electron transducer material. The solid-contact material is then covered by a selective polyvinyl chloride (PVC) membrane incorporated with 18-crown-6 as a neutral ion carrier for the selective determination of copper(II) ions. The proposed electrode exhibits a Nernstian response with a slope of 30.2 ± 0.3 mV/decade (R2 = 0.999) over the linear concentration range 5.2 × 10-9 - 6.2 × 10-3 mol/l and a detection limit of 1.1 × 10-9 mol/l (69.9 ng/l). Short-term potential stability is evaluated using constant current chronopotentiometry (CP) and electrochemical impedance spectroscopy (EIS). A significant improvement in the electrode capacitance (91.5 µF) is displayed due to the use of Mn2O3-NPs as a solid contact. The presence of Nafion, with its high hydrophobicity properties, eliminates the formation of the thin water layer, facilitating the ion-to-electron transduction between the sensing membrane and the conducting substrate. Additionally, it enhances the adhesion of the polymeric sensing membrane to the solid-contact material, preventing membrane delamination and increasing the electrode's lifespan. The high selectivity, sensitivity, and potential stability of the proposed miniaturized electrode suggests its use for the determination of copper(II) ions in human blood serum and milk samples. The results obtained agree fairly well with data obtained by flameless atomic absorption spectrometry.


Assuntos
Cobre , Éteres de Coroa , Eletrodos , Polímeros de Fluorcarboneto , Limite de Detecção , Compostos de Manganês , Óxidos , Potenciometria , Cobre/química , Polímeros de Fluorcarboneto/química , Óxidos/química , Compostos de Manganês/química , Humanos , Potenciometria/instrumentação , Potenciometria/métodos , Éteres de Coroa/química , Grafite/química
15.
Anal Chim Acta ; 1307: 342628, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719415

RESUMO

Bisphenol compounds (BPA, BPS, BPAF, etc.) are one class of the most important and widespread pollutants that poses severe threat to human health and the ecological environment. Because of the presence of multiple bisphenols in environmental and food samples, it is urgent and challenging to develop a rapid and cheap technique for simultaneously detecting BPA and its analogues. In this study, a series of M-N-C (M = Cu, Mg, Ni, Co, Fe, K) single-atom nanozymes (SAzymes) were created by simulating the structure of natural enzyme molecules, which were used as novel sensing platform for the fabrication of electrochemical sensors. Through systematic screening and characterization, it was interestingly discovered that the electrochemical sensor based on Cu-N-C SAzymes exhibited the best sensing performance for bisphenols among all SAzymes, which catalyzed not only BPA like tyrosinase, but also showed excellent catalytic capacity beyond tyrosinase (tyrosinase has no catalytic activity for BPS, BPAF, etc.), and achieved potential-resolved simultaneous rapid detection of BPA, BPS and BPAF. Further structure-activity relationship and catalytic mechanism characterizations of Cu-N-C SAzymes revealed that the presence of single atom Cu was predominantly in the form of Cu+ and Cu2+, which were anchored onto graphene nanosheet support through four coordination bonds with pyridinic N and pyrrolic N and acted as highly efficient active centers for electrocatalytic oxidation of bisphenols. The developed electrochemical sensing method exhibited excellent selectivity, sensitivity, and reliability for the rapid detection of multiple bisphenols in actual samples.


Assuntos
Compostos Benzidrílicos , Técnicas Eletroquímicas , Fenóis , Fenóis/análise , Fenóis/química , Compostos Benzidrílicos/análise , Técnicas Eletroquímicas/métodos , Nanoestruturas/química , Catálise , Cobre/química , Grafite/química , Limite de Detecção
16.
Mikrochim Acta ; 191(6): 344, 2024 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-38802523

RESUMO

A molecularly imprinted electrochemiluminescent sensor is developed for the sensitive detection of tetracycline in environmental and food samples. The sensor uses an ionic liquid (i.e. [APMIM]Br) modified graphene-carbon nanotube composite (GMI) material as substrate, a double-layered core-shell metal-organic framework NH2-UiO-66@ZIF-8 (NUZ) loaded bipyridyl ruthenium (NUZ@Ru) as luminescent material, and a molecularly imprinted copolymer of o-phenylenediamine and hydroquinone as recognition element. The ionic liquid-modified graphene-carbon nanotube composite has a favorable three-dimensional structure, high specific surface area, and good hydrophilicity; the core-shell structured metal-organic framework has high stability and plentiful reaction sites for loading; the molecularly imprinted copolymer film has enhanced stability and recognition effect. Hence, the resulting sensor combines the merits of several materials and presents improved performance. Under the optimum detection conditions, it shows a wide linear range of 0.05 µM - 1 mM, a low detection limit of 20 nM, high selectivity, and excellent stability. It has been successfully applied to the detection of tetracycline in different samples.


Assuntos
Técnicas Eletroquímicas , Limite de Detecção , Medições Luminescentes , Estruturas Metalorgânicas , Polímeros Molecularmente Impressos , Tetraciclina , Tetraciclina/análise , Tetraciclina/química , Polímeros Molecularmente Impressos/química , Estruturas Metalorgânicas/química , Medições Luminescentes/métodos , Técnicas Eletroquímicas/métodos , Grafite/química , Nanotubos de Carbono/química , Contaminação de Alimentos/análise , Líquidos Iônicos/química , Antibacterianos/análise , Antibacterianos/química , Poluentes Químicos da Água/análise , Impressão Molecular
17.
Anal Chim Acta ; 1308: 342647, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38740456

RESUMO

BACKGROUND: Presently, glyphosate (Gly) is the most extensively used herbicide globally, Nevertheless, its excessive usage has increased its accumulation in off-target locations, and aroused concerns for food and environmental safety. Commonly used detection methods, such as high-performance liquid chromatography and gas chromatography, have limitations due to expensive instruments, complex pre-processing steps, and inadequate sensitivity. Therefore, a facile, sensitive, and reliable Gly detection method should be developed. RESULTS: A photoelectrochemical (PEC) sensor consisting of a three-dimensional polymer phenylethnylcopper/nitrogen-doped graphene aerogel (PPhECu/3DNGA) electrode coupled with Fe3O4 NPs nanozyme was constructed for sensitive detection of Gly. The microscopic 3D network of electrodes offered fast transfer routes for photo-generated electrons and a large surface area for nanozyme loading, allowing high signal output and analytical sensitivity. Furthermore, the use of peroxidase-mimicking Fe3O4 NPs instead of natural enzyme improved the stability of the sensor against ambient temperature changes. Based on the inhibitory effect of Gly on the catalytic activity Fe3O4 NPs, the protocol achieved Gly detection in the range of 5 × 10-10 to 1 × 10-4 mol L-1. Additionally, feasibility of the detection was confirmed in real agricultural matrix including tea, maize seedlings, maize seeds and soil. SIGNIFICANCE: This work achieved facile, sensitive and reliable analysis towards Gly, and it was expected to inspire the design and utilization of 3D architectures in monitoring agricultural chemicals in food and environmental matrix.


Assuntos
Técnicas Eletroquímicas , Eletrodos , Glicina , Glifosato , Grafite , Nitrogênio , Processos Fotoquímicos , Grafite/química , Glicina/análogos & derivados , Glicina/química , Glicina/análise , Nitrogênio/química , Polímeros/química , Cobre/química , Géis/química , Herbicidas/análise , Limite de Detecção , Nanopartículas de Magnetita/química , Nanopartículas Magnéticas de Óxido de Ferro/química
18.
Biosens Bioelectron ; 258: 116315, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38701536

RESUMO

Research in electrochemical detection in lateral flow assays (LFAs) has gained significant momentum in recent years. The primary impetus for this surge in interest is the pursuit of achieving lower limits of detection, especially given that LFAs are the most widely employed point-of-care biosensors. Conventionally, the strategy for merging electrochemistry and LFAs has centered on the superposition of screen-printed electrodes onto nitrocellulose substrates during LFA fabrication. Nevertheless, this approach poses substantial limitations regarding scalability. In response, we have developed a novel method for the complete integration of reduced graphene oxide (rGO) electrodes into LFA strips. We employed a CO2 laser to concurrently reduce graphene oxide and pattern nitrocellulose, exposing its backing to create connection sites impervious to sample leakage. Subsequently, rGO and nitrocellulose were juxtaposed and introduced into a roll-to-roll system using a wax printer. The exerted pressure facilitated the transfer of rGO onto the nitrocellulose. We systematically evaluated several electrochemical strategies to harness the synergy between rGO and LFAs. While certain challenges persist, our rGO transfer technology presents compelling potential for setting a new standard in electrochemical LFA fabrication.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Eletrodos , Grafite , Sistemas Automatizados de Assistência Junto ao Leito , Grafite/química , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Humanos , Desenho de Equipamento , Colódio/química , Testes Imediatos , Limite de Detecção , Oxirredução
19.
Bioorg Chem ; 147: 107418, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38703441

RESUMO

A key approach in developing green chemistry involves converting solar energy into chemical energy of biomolecules through photocatalysis. Photocatalysis can facilitate the regeneration of nicotinamide cofactors during redox processes. Nicotinamide cofactor biomimetics (NCBs) are economical substitutes for natural cofactors. Here, photocatalytic regeneration of NADH and reduced NCBs (NCBsred) using graphitic carbon nitride (g-C3N4) was developed. The process involves g-C3N4 as the photocatalyst, Cp*Rh(bpy)H2O2+ as the electron mediator, and Triethanolamine as the electron donor, facilitating the reduction of NAD+ and various oxidative NCBs (NCBsox) under light irradiation. Notably, the highest reduction yield of 48.32 % was achieved with BANA+, outperforming the natural cofactor NAD+. Electrochemical analysis reveals that the reduction efficiency and capacity of cofactors relies on their redox potentials. Additionally, a coupled photo-enzymatic catalysis system was explored for the reduction of 4-Ketoisophorone by Old Yellow Enzyme XenA. Among all the NCBsox and NAD+, the highest conversion ratio of over 99 % was obtained with BANA+. After recycled for 8 times, g-C3N4 maintained over 93.6 % catalytic efficiency. The photocatalytic cofactor regeneration showcases its outstanding performance with NAD+ as well as NCBsox. This work significantly advances the development of photocatalytic cofactor regeneration for artificial cofactors and its potential application.


Assuntos
Biocatálise , Oxirredução , Processos Fotoquímicos , Materiais Biomiméticos/química , Materiais Biomiméticos/metabolismo , Estrutura Molecular , NAD/química , NAD/metabolismo , Biomimética , Niacinamida/química , Niacinamida/metabolismo , Compostos de Nitrogênio/química , Grafite
20.
ACS Appl Bio Mater ; 7(5): 3358-3374, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38717870

RESUMO

Exosomes are promising nanocarriers for drug delivery. Yet, it is challenging to apply exosomes in clinical use due to the limited understanding of their physiological functions. While cellular uptake of exosomes is generally known through endocytosis and/or membrane fusion, the mechanisms of origin-dependent cellular uptake and subsequent cargo release of exosomes into recipient cells are still unclear. Herein, we investigated the intricate mechanisms of exosome entry into recipient cells and intracellular cargo release. In this study, we utilized chiral graphene quantum dots (GQDs) as representatives of exosomal cargo, taking advantage of the superior permeability of chiral GQDs into lipid membranes as well as their excellent optical properties for tracking analysis. We observed that the preferential cellular uptake of exosomes derived from the same cell-of-origin (intraspecies exosomes) is higher than that of exosomes derived from different cell-of-origin (cross-species exosomes). This uptake enhancement was attributed to receptor-ligand interaction-mediated endocytosis, as we identified the expression of specific ligands on exosomes that favorably interact with their parental cells and confirmed the higher lysosomal entrapment of intraspecies exosomes (intraspecies endocytic uptake). On the other hand, we found that the uptake of cross-species exosomes primarily occurred through membrane fusion, followed by direct cargo release into the cytosol (cross-species direct fusion uptake). We revealed the underlying mechanisms involved in the cellular uptake and subsequent cargo release of exosomes depending on their cell-of-origin and recipient cell types. Overall, this study envisions valuable insights into further advancements in effective drug delivery using exosomes, as well as a comprehensive understanding of cellular communication, including disease pathogenesis.


Assuntos
Exossomos , Pontos Quânticos , Pontos Quânticos/química , Exossomos/metabolismo , Exossomos/química , Humanos , Materiais Biocompatíveis/química , Materiais Biocompatíveis/metabolismo , Materiais Biocompatíveis/farmacologia , Corantes Fluorescentes/química , Tamanho da Partícula , Teste de Materiais , Endocitose , Grafite/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA