Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.072
Filtrar
1.
Int J Colorectal Dis ; 39(1): 85, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38837095

RESUMO

BACKGROUND: Rectal cancer (RC) is a surgical challenge due to its technical complexity. The double-stapled (DS) technique, a standard for colorectal anastomosis, has been associated with notable drawbacks, including a high incidence of anastomotic leak (AL). Low anterior resection with transanal transection and single-stapled (TTSS) anastomosis has emerged to mitigate those drawbacks. METHODS: Observational study in which it described the technical aspects and results of the initial group of patients with medium-low RC undergoing elective laparoscopic total mesorectal excision (TME) and TTSS. RESULTS: Twenty-two patients were included in the series. Favourable postoperative outcomes with a median length of stay of 5 days and an AL incidence of 9.1%. Importantly, all patients achieved complete mesorectal excision with tumour-free margins, and no mortalities were reported. CONCLUSION: TTSS emerges as a promising alternative for patients with middle and lower rectal tumours, offering potential benefits in terms of morbidity reduction and oncological integrity compared with other techniques.


Assuntos
Canal Anal , Anastomose Cirúrgica , Neoplasias Retais , Grampeamento Cirúrgico , Humanos , Masculino , Feminino , Anastomose Cirúrgica/métodos , Pessoa de Meia-Idade , Idoso , Neoplasias Retais/cirurgia , Canal Anal/cirurgia , Grampeamento Cirúrgico/métodos , Resultado do Tratamento , Reto/cirurgia , Laparoscopia/métodos , Fístula Anastomótica/etiologia , Fístula Anastomótica/prevenção & controle , Adulto , Idoso de 80 Anos ou mais
2.
Langenbecks Arch Surg ; 409(1): 184, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38862717

RESUMO

PURPOSE: Post-operative pancreatic fistula (POPF) remains the main complication after distal pancreatectomy (DP). The aim of this study is to evaluate the potential benefit of different durations of progressive stapler closure on POPF rate and severity after DP. METHODS: Patients who underwent DP between 2016 and 2023 were retrospectively enrolled and divided into two groups according to the duration of the stapler closure: those who underwent a progressive compression for < 10 min and those for ≥ 10 min. RESULTS: Among 155 DPs, 83 (53.5%) patients underwent pre-firing compression for < 10 min and 72 (46.5%) for ≥ 10 min. As a whole, 101 (65.1%) developed POPF. A lower incidence rate was found in case of ≥ 10 min compression (34-47.2%) compared to < 10 min compression (67- 80.7%) (p = 0.001). When only clinically relevant (CR) POPFs were considered, a prolonged pre-firing compression led to a lower rate (15-20.8%) than the < 10 min cohort (32-38.6%; p = 0.02). At the multivariate analysis, a compression time of at least 10 min was confirmed as a protective factor for both POPF (OR: 5.47, 95% CI: 2.16-13.87; p = 0.04) and CR-POPF (OR: 2.5, 95% CI: 1.19-5.45; p = 0.04) development. In case of a thick pancreatic gland, a prolonged pancreatic compression for at least 10 min was significantly associated to a lower rate of CR-POPF compared to < 10 min (p = 0.04). CONCLUSION: A prolonged pre-firing pancreatic compression for at least 10 min seems to significantly reduce the risk of CR-POPF development. Moreover, significant advantages are documented in case of a thick pancreatic gland.


Assuntos
Pancreatectomia , Fístula Pancreática , Complicações Pós-Operatórias , Grampeamento Cirúrgico , Humanos , Fístula Pancreática/prevenção & controle , Fístula Pancreática/etiologia , Pancreatectomia/efeitos adversos , Pancreatectomia/métodos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Grampeamento Cirúrgico/métodos , Grampeadores Cirúrgicos , Adulto , Fatores de Tempo , Neoplasias Pancreáticas/cirurgia
4.
BMJ Case Rep ; 17(5)2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38740444

RESUMO

With the advancements in the medical field, many innovations in medical devices have happened. Using a surgical stapler to close the laryngectomy defect without opening the pharynx is particularly advantageous in a total laryngectomy (TL). However, performing the tracheoesophageal puncture (TEP) during stapler closure of the larynx has not been widely advocated, due to the fear of complications related to the procedure.We treated two male patients with advanced glottic malignancy who underwent a TL. To restore their ability to speak, we performed a primary TEP and immediate voice prosthesis placement. After the TEP, we closed the larynx using a stapler. The surgical technique used in this procedure has been thoroughly explained.The use of a surgical stapler for pharyngeal closure during a TL has several advantages, particularly with regard to the duration of surgery. The current techniques appear to be promising in reducing TEP-related complications during stapler-assisted laryngeal closure.


Assuntos
Neoplasias Laríngeas , Laringectomia , Punções , Traqueia , Humanos , Masculino , Laringectomia/métodos , Laringectomia/efeitos adversos , Neoplasias Laríngeas/cirurgia , Punções/métodos , Traqueia/cirurgia , Esôfago/cirurgia , Grampeadores Cirúrgicos , Idoso , Pessoa de Meia-Idade , Laringe/cirurgia , Grampeamento Cirúrgico/métodos , Laringe Artificial
5.
Surg Laparosc Endosc Percutan Tech ; 34(3): 290-294, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38736400

RESUMO

BACKGROUND: Despite the success of bariatric surgery in treating obesity, it can still lead to complications. The most serious and feared technical complications are bleeding and leakage from the gastric staple line. In this study, stapler line reinforcement was investigated to determine whether it affects postoperative leakage and bleeding rates and their management. MATERIALS AND METHODS: Overall, 510 patients who underwent sleeve gastrectomy were evaluated retrospectively. They were divided into 2 groups according to whether reinforcement of the staple line with running imbricating sutures was performed. RESULTS: In the reinforcement group, there were two leaks (0.7%), which were diagnosed seven and eight days after surgery. In the non-reinforcement group, there were nine leaks (4%). There was no difference between the two groups in staple line bleeding. CONCLUSIONS: This study shows that reinforcement with continuous imbricating sutures is associated with less stapler line leakage and a lower reoperation rate at the cost of increased operative time.


Assuntos
Fístula Anastomótica , Gastrectomia , Laparoscopia , Obesidade Mórbida , Grampeamento Cirúrgico , Humanos , Feminino , Masculino , Estudos Retrospectivos , Laparoscopia/métodos , Adulto , Gastrectomia/métodos , Gastrectomia/efeitos adversos , Grampeamento Cirúrgico/métodos , Fístula Anastomótica/prevenção & controle , Fístula Anastomótica/etiologia , Obesidade Mórbida/cirurgia , Pessoa de Meia-Idade , Resultado do Tratamento , Técnicas de Sutura , Reoperação , Duração da Cirurgia , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia
6.
Dis Colon Rectum ; 67(S1): S26-S35, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38710588

RESUMO

BACKGROUND: Available techniques for IPAA in ulcerative colitis include handsewn, double-stapled, and single-stapled anastomoses. There are controversies, indications, and different outcomes regarding these techniques. OBJECTIVE: To describe technical details, indications, and outcomes of 3 specific types of anastomoses in restorative proctocolectomy. DATA SOURCE: Systematic literature review for articles in the PubMed database according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria. STUDY SELECTION: Studies describing outcomes of the 3 different types of anastomoses, during pouch surgery, in patients undergoing restorative proctocolectomy for ulcerative colitis. INTERVENTION: IPAA technique. MAIN OUTCOME MEASURES: Postoperative outcomes (anastomotic leaks, overall complication rates, and pouch function). RESULTS: Twenty-one studies were initially included: 6 studies exclusively on single-stapled IPAA, 2 exclusively on double-stapled IPAA, 6 studies comparing single-stapled to double-stapled techniques, 6 comparing double-stapled to handsewn IPAA, and 1 comprising single-stapled to handsewn IPAA. Thirty-seven studies were added according to authors' discretion as complementary evidence. Between 1990 and 2015, most studies were related to double-stapled IPAA, either only analyzing the results of this technique or comparing it with the handsewn technique. Studies published after 2015 were mostly related to transanal approaches to proctectomy for IPAA, in which a single-stapled anastomosis was introduced instead of the double-stapled anastomosis, with some studies comparing both techniques. LIMITATIONS: A low number of studies with handsewn IPAA technique and a large number of studies added at authors' discretion were the limitations of this strudy. CONCLUSIONS: Handsewn IPAA should be considered if a mucosectomy is performed for dysplasia or cancer in the low rectum or, possibly, for re-do surgery. Double-stapled IPAA has been more widely adopted for its simplicity and for the advantage of preserving the anal transition zone, having lower complications, and having adequate pouch function. The single-stapled IPAA offers a more natural design, is feasible, and is associated with reasonable outcomes compared to double-stapled anastomosis. See video from symposium.


Assuntos
Anastomose Cirúrgica , Colite Ulcerativa , Proctocolectomia Restauradora , Humanos , Colite Ulcerativa/cirurgia , Proctocolectomia Restauradora/métodos , Proctocolectomia Restauradora/efeitos adversos , Anastomose Cirúrgica/métodos , Anastomose Cirúrgica/efeitos adversos , Grampeamento Cirúrgico/métodos , Fístula Anastomótica/etiologia , Fístula Anastomótica/epidemiologia , Bolsas Cólicas/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento
7.
Arq Bras Cir Dig ; 37: e1800, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38716920

RESUMO

BACKGROUND: One of the primary complications associated with large incisions in abdominal surgery is the increased risk of fascial closure rupture and incisional hernia development. The choice of the fascial closure method and closing with minimal tension and trauma is crucial for optimal results, emphasizing the importance of uniform pressure along the suture line to withstand intra-abdominal pressure. AIMS: To evaluate the resistance to pressure and tension of stapled and sutured hand-sewn fascial closure in the abdominal wall. METHODS: Nine abdominal wall flaps from human cadavers and 12 pigs were used for the experimentation. An abdominal defect was induced after the resection of the abdominal wall and the creation of a flap in the cadaveric model and after performing a midline incision in the porcine models. The models were randomized into three groups. Group 1 was treated with a one-layer hand-sewn small bite suture, Group 2 was treated with a two-layer hand-sewn small bite suture, and Group 3 was treated with a two-layer stapled closure. Tension measurements were assessed in cadaveric models, and intra-abdominal pressure was measured in porcine models. RESULTS: In the human cadaveric model, the median threshold for fascial rupture was 300N (300-350) in Group 1, 400N (350-500) in Group 2, and 350N (300-380) in Group 3. Statistical comparisons revealed non-significant differences between Group 1 and Group 2 (p=0.072, p>0.05), Group 1 and Group 3 (p=0.346, p>0.05), and Group 2 and Group 3 (p=0.184, p>0.05). For porcine subjects, Group 1 showed a median pressure of 80 mmHg (85-105), Group 2 had a median of 92.5 mmHg (65-95), and Group 3 had a median of 102.5 mmHg (80-135). Statistical comparisons indicated non-significant differences between Group 1 and Group 2 (p=0.243, p>0.05), Group 1 and Group 3 (p=0.468, p>0.05), and Group 2 and Group 3 (p=0.083, p>0.05). CONCLUSIONS: Stapled and conventional suturing resist similar pressure and tension thresholds.


Assuntos
Parede Abdominal , Cadáver , Técnicas de Sutura , Humanos , Animais , Suínos , Parede Abdominal/cirurgia , Técnicas de Fechamento de Ferimentos Abdominais , Grampeamento Cirúrgico , Modelos Animais , Fasciotomia/métodos , Feminino , Masculino
8.
BMC Surg ; 24(1): 130, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38698365

RESUMO

BACKGROUND: Anastomosis configuration is an essential step in treatment to restore continuity of the gastrointestinal tract following bowel resection in patients with Crohn's disease (CD). However, the association between anastomotic type and surgical outcome remains controversial. This retrospective study aimed to compare early postoperative complications and surgical outcome between stapler and handsewn anastomosis after bowel resection in Crohn's disease. METHODS: Between 2001 and 2018, a total of 339 CD patients underwent bowel resection with anastomosis. Patient characteristics, intraoperative data, early postoperative complications, and outcomes were analyzed and compared between two groups of patients. Group 1 consisted of patients with stapler anastomosis and group 2 with handsewn anastomosis. RESULTS: No significant difference was found in the incidence of postoperative surgical complications between the stapler and handsewn anastomosis groups (25% versus 24.4%, p = 1.000). Reoperation for complications and postoperative hospital stay were similar between the two groups. CONCLUSION: Our analysis showed that there were no differences in anastomotic leak, nor postoperative complications, mortality, reoperation for operative complications, or postoperative hospital stay between the stapler anastomosis and handsewn anastomosis groups.


Assuntos
Anastomose Cirúrgica , Doença de Crohn , Complicações Pós-Operatórias , Grampeamento Cirúrgico , Humanos , Doença de Crohn/cirurgia , Feminino , Masculino , Anastomose Cirúrgica/métodos , Estudos Retrospectivos , Adulto , Grampeamento Cirúrgico/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Pessoa de Meia-Idade , Técnicas de Sutura , Reoperação/estatística & dados numéricos , Resultado do Tratamento , Tempo de Internação/estatística & dados numéricos , Fístula Anastomótica/epidemiologia , Fístula Anastomótica/etiologia , Adulto Jovem
10.
J Gastrointest Surg ; 28(6): 820-823, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38599994

RESUMO

BACKGROUND: There is a lack of evidence regarding anastomotic technique and postoperative complications in gastric cancer surgery. This study aimed to evaluate whether there are differences between stapled and handsewn anastomosis and anastomotic leaks. METHODS: This was a population-based, retrospective, nationwide cohort study in Finland using the Finnish National Esophago-Gastric Cancer Cohort. Patients undergoing gastrectomy with available postoperative complication data were included. Logistic regression analysis was used to calculate the odds ratios with 95% CIs, adjusted for calendar period of surgery, age at surgery, sex, comorbidity, tumor stage, neoadjuvant therapy, minimally invasive surgery, type of gastrectomy, radical resection, and type of anastomosis. RESULTS: Of the 2164 patients, 472 of all patients (21.8%) had handsewn anastomosis and 1692 of all patients (78.2%) had stapled anastomosis. In the unadjusted analysis, anastomotic leaks were significantly lower in the handsewn group (hazard ratio [HR], 0.42; 95% CI, 0.22-0.79) than the stapled group, but after adjustment for known prognostic factors, this association was no longer significant (HR, 0.57; 95% CI, 0.27-1.21). In the analysis stratified by gastrectomy type (distal or total), no differences in anastomotic leaks were observed between anastomotic techniques. CONCLUSION: In this population-based nationwide study, anastomotic technique (stapled or handsewn) was not associated with anastomotic leaks in any, distal or total, gastrectomy.


Assuntos
Anastomose Cirúrgica , Fístula Anastomótica , Gastrectomia , Neoplasias Gástricas , Grampeamento Cirúrgico , Humanos , Neoplasias Gástricas/cirurgia , Masculino , Feminino , Fístula Anastomótica/epidemiologia , Fístula Anastomótica/etiologia , Finlândia/epidemiologia , Gastrectomia/efeitos adversos , Gastrectomia/métodos , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/métodos , Grampeamento Cirúrgico/efeitos adversos , Técnicas de Sutura
11.
Langenbecks Arch Surg ; 409(1): 145, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38687358

RESUMO

BACKGROUND: A stapler is usually used for transection and closure of the pancreas in distal pancreatectomy (DP) or central pancreatectomy (CP). When the pancreas is transected to the right of the portal vein, it is difficult to use a stapler and clinically relevant postoperative pancreatic fistula (CR-POPF) frequently occurs. We report on the efficacy of pancreaticojejunostomy (PJ) of the pancreatic stump for patients in whom stapler use is difficult. METHODS: Patients who underwent DP or CP were enrolled in this study. The pancreas was usually transected by a stapler, and ultrasonic coagulating shears (UCS) were used depending on the tumor situation. When using UCS, hand-sewn closure or PJ was performed for the pancreatic stump. The relationship between clinicopathological factors and the methods of pancreatic transection and closure were investigated. RESULTS: In total, 164 patients underwent DP or CP, and the pancreas was transected with a stapler in 150 patients and UCS in 14 patients. The rate of CR-POPF was higher and the postoperative hospital stay was longer in the UCS group than in the stapler group. PJ of the pancreatic stump, which was performed for 7 patients, did not worsen intraoperative factors. CR-POPF was not seen in these 7 patients, which was significantly less than that with hand-sewn closure. CONCLUSIONS: PJ of the pancreatic stump during DP or CP reduces CR-POPF compared with hand-sewn closure and may be useful especially when the pancreas is transected to the right of the portal vein.


Assuntos
Pancreatectomia , Fístula Pancreática , Neoplasias Pancreáticas , Pancreaticojejunostomia , Humanos , Pancreaticojejunostomia/métodos , Pancreatectomia/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Fístula Pancreática/prevenção & controle , Fístula Pancreática/etiologia , Neoplasias Pancreáticas/cirurgia , Neoplasias Pancreáticas/patologia , Adulto , Resultado do Tratamento , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Grampeamento Cirúrgico , Tempo de Internação , Grampeadores Cirúrgicos , Técnicas de Sutura
12.
Am J Case Rep ; 25: e942824, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38654503

RESUMO

BACKGROUND Bariatric surgery (BS) has a lower percentage of complications than other abdominal surgeries. Hemorrhage in one of the most common complications and can be life-threatening. Hereditary factor XI (FXI) deficiency is a coagulation disorder that can result in excessive bleeding requiring intervention to restore hemostasis. Risks over benefits in patients with morbid obesity with BS indication, as well as those with FXI deficiency, should be carefully evaluated. This article reports the case of an obese woman with FXI deficiency -undergoing SG. CASE REPORT A 49-year-old woman with a BMI of 51 kg/m² was diagnosed as having severe FXI deficiency during preoperative exams prior to bariatric surgery. Virus-inactivated homo-group plasma 10 ml/kg infusion was administrated 1 h before surgery, during the entire procedure, and continuing until postoperative day (POD) 4. A very low-calorie ketogenic diet (VLCKD) was proposed to the patient 4 weeks before surgery. Laparoscopic sleeve gastrectomy was performed with staple-line reinforcement by oversewing the seromuscular layer using continuous suture. Subcutaneous enoxaparin 4000 U.I. was administered from POD 1 until POD 25 to prevent any thromboembolic event. The patient was discharged on POD 5 in good clinical condition. CONCLUSIONS Risks of bleeding andor thromboembolic events before or after BS are increased in patient with FXI deficiency. Bariatric surgery in these patients is safe in experienced BS centers, and the risks associated with the obesity seem to exceed those of the coagulopathy and surgery. Careful preoperative counseling, extensive hematological checks, and meticulous surgery are essential to reduce BS risks. Sleeve gastrectomy oversewing the stapler line seems a reasonable choice.


Assuntos
Deficiência do Fator XI , Gastrectomia , Laparoscopia , Obesidade Mórbida , Humanos , Feminino , Pessoa de Meia-Idade , Gastrectomia/métodos , Deficiência do Fator XI/complicações , Obesidade Mórbida/cirurgia , Grampeamento Cirúrgico
13.
ANZ J Surg ; 94(4): 604-613, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38456319

RESUMO

BACKGROUND: Approach to enteric anastomotic technique has been a subject of debate, with no clear consensus as to whether handsewn or stapled techniques are superior in trauma settings, which are influenced by unique perturbances to important processes such as immune function, coagulation, wound healing and response to infection. This systematic review and meta-analysis compares the risk of anastomotic complications in trauma patients with gastrointestinal injury requiring restoration of continuity with handsewn versus staples approaches. METHODS: A comprehensive computer assisted search of electronic databases Medline, Embase and Cochrane Central was performed. Comparative studies evaluating stapled versus handsewn gastrointestinal anastomoses in trauma patients were included in this review. All anastomoses involving small intestine to small intestine, small to large intestine, and large intestine to large intestine were eligible. Anastomosis to the rectum was excluded. Outcomes evaluated were (1) anastomotic leak (AL) (2) a composite anastomotic complication (CAC) end point consisting of AL, enterocutaneous fistula (ECF) and deep abdominal abscess. RESULTS: Eight studies involving 931 patients were included and of these patients, data from 790 patients were available for analysis. There was no significant difference identified for anastomotic leak between the two groups (OR = 0.77; 95% CI 0.24-2.45; P = 0.66). There was no significant improvement in composite anastomotic complication; defined as a composite of anastomotic leak, deep intra-abdominal abscess and intra-abdominal fistula, in the stapled anastomosis group (OR = 1.05; 95% CI 0.53-2.09; P = 0.90). Overall, there was limited evidence to suggest superiority with handsewn or stapled anastomosis for improving AL or CAC, however this was based on studies of moderate to high risk of bias with poor control for confounders. DISCUSSION: This meta-analysis demonstrates no superiority improvement in anastomotic outcomes with handsewn or stapled repair. These findings may represent no effect in anastomotic outcome by technique for all situations. However, considering the paucity of information on potential confounders, perhaps there is a difference in outcome with overall technique or for specific subgroups that have not been described due to limited sample size and data on confounders. Currently, there is insufficient evidence to recommend an anastomotic technique in trauma.


Assuntos
Fístula Anastomótica , Técnicas de Sutura , Humanos , Fístula Anastomótica/epidemiologia , Fístula Anastomótica/cirurgia , Grampeamento Cirúrgico , Anastomose Cirúrgica/métodos , Reto/cirurgia
14.
BMC Gastroenterol ; 24(1): 112, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38491416

RESUMO

PURPOSE: Rectal anastomoses have a persisting high incidence of anastomotic leakage. This study aimed to assess whether the use of a poly-ϵ-caprolactone (PCL) scaffold as reinforcement of a circular stapled rectal anastomosis could increase tensile strength and improve healing compared to a control in a piglet model. METHOD: Twenty weaned female piglets received a stapled rectal anastomosis and were randomised to either reinforcement with PCL scaffold (intervention) or no reinforcement (control). On postoperative day five the anastomosis was subjected to a tensile strength test followed by a histological examination to evaluate the wound healing according to the Verhofstad scoring. RESULTS: The tensile strength test showed no significant difference between the two groups, but histological evaluation revealed significant impaired wound healing in the intervention group. CONCLUSION: The incorporation of a PCL scaffold into a circular stapled rectal anastomosis did not increase anastomotic tensile strength in piglets and indicated an impaired histologically assessed wound healing.


Assuntos
Fístula Anastomótica , Caproatos , Lactonas , Grampeamento Cirúrgico , Animais , Feminino , Anastomose Cirúrgica/efeitos adversos , Fístula Anastomótica/prevenção & controle , Fístula Anastomótica/etiologia , Reto/cirurgia , Suínos
15.
Vet Surg ; 53(4): 733-741, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38444078

RESUMO

OBJECTIVE: To compare time to construct completion and leak testing between hand-sewn and skin staple anastomoses and enterotomies in cats. STUDY DESIGN: Ex vivo, randomized study. ANIMALS: Fresh feline cadavers (n = 20). METHODS: Jejunal segments (8 cm) were harvested and tested on the same day as euthanasia. From each cadaver, one segment was randomly assigned to control (C), hand-sewn enterotomy (HSE), and skin staple enterotomy (SSE) groups, and two segments were randomly assigned to hand-sewn anastomosis (HSA) and skin staple anastomosis (SSA) groups. Construct completion time, initial leak pressure (ILP), and maximum intraluminal pressure were compared. Leakage location was reported. RESULTS: Mean time (s) ± SD was longer (p < .001) for HSA (317.0 ± 50.9) than SSA (160.8 ± 13.1) and for HSE (172.0 ± 36.5) than SSE (20.3 ± 5.0). ILP (mean ± SD) for C (600.0 mmHg ±0.0) was higher (p < .001) than all constructs. ILP (mean ± SD) for SSA (124.2 mmHg ±83.7) was not different (p = .49) than HSA (86.1 ± 51.9), but HSE (200.3 ± 114.7) was higher (p < .001) than SSE (32.2 ± 39.7). Immediate leakage from the center of enterotomy closure was observed in 7/20 SSE. CONCLUSIONS: HSA construct completion took twice as long as SSA with no difference in intraluminal pressures. Although HSE construct completion took 8x as long as SSE, HSE had higher intraluminal pressures. CLINICAL SIGNIFICANCE: In cats, SSA may be an alternative to HSA for intestinal anastomosis, but SSE is not recommended as an alternative to HSE for intestinal enterotomy closure.


Assuntos
Anastomose Cirúrgica , Cadáver , Animais , Gatos/cirurgia , Anastomose Cirúrgica/veterinária , Anastomose Cirúrgica/métodos , Grampeamento Cirúrgico/veterinária , Grampeamento Cirúrgico/métodos , Técnicas de Sutura/veterinária , Pressão
17.
Colorectal Dis ; 26(4): 754-759, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38443753

RESUMO

AIM: Creation of an overlapped anastomosis using handsewn sutures for common enterotomy is very popular in robotic right colectomy (RRC) with intracorpareal anastomosis (IA). The aim of this study is to present a simple method for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in RRC with IA. METHOD: The distal ileum and proximal colon were put in overlapping positions. Enterotomies were created 2 cm proximal to the ileal stump and 8 cm distal to the colonic stump on the antimesenteric side. Subsequently, a 60 mm linear stapler with a reinforced bioabsorbable material was inserted into each lumen and fired. Finally, the bowel was elevated while holding the bioabsorbable material, and the common enterotomy was grasped with the robotic instrument in the middle and closed using a linear stapler with a reinforced bioabsorbable material. RESULTS: This technique was applied to 10 patients with tumours of the caecum, ascending colon, or transverse colon. The median operating time, anastomosis construction time, blood loss, and postoperative stay were 281 min (range 228-459 min), 12 min (range 11-17 min), 10 mL (range 0-110 mL), and 10 days (range 8-15 days), respectively. No adverse intraoperative events were observed. Postoperatively, one patient developed chylous ascites, but there were no other complications. CONCLUSION: The simple technique for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis appears to be safe and feasible.


Assuntos
Implantes Absorvíveis , Anastomose Cirúrgica , Colectomia , Neoplasias do Colo , Íleo , Procedimentos Cirúrgicos Robóticos , Grampeadores Cirúrgicos , Colectomia/métodos , Colectomia/instrumentação , Humanos , Anastomose Cirúrgica/métodos , Anastomose Cirúrgica/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Neoplasias do Colo/cirurgia , Íleo/cirurgia , Procedimentos Cirúrgicos sem Sutura/métodos , Procedimentos Cirúrgicos sem Sutura/instrumentação , Duração da Cirurgia , Colo/cirurgia , Resultado do Tratamento , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/instrumentação , Adulto , Tempo de Internação
18.
Asian J Endosc Surg ; 17(2): e13293, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38452773

RESUMO

Vascular staplers are routinely used in laparoscopic liver resection, which has become a standard procedure in advanced medical facilities. Although previous reports have outlined the benefits of staple line reinforcement (SLR), its application in Glissonean pedicle transection during hepatic resection remains poorly studied. This study investigated surgical SLR as a tool to enhance staple line strength and improve perioperative hemostasis. Here, 10 patients who underwent laparoscopic liver resection using the Tri-StapleTM2.0 Reinforced Reload were included. Patient characteristics, surgical details, and outcomes were assessed. The results demonstrated successful outcomes with no complications related to bile leakage or injuries during staple insertion. Overall, our findings suggest that SLR can be safely utilized in Glissonean pedicle transection during laparoscopic liver resections. Further studies are required to comprehensively evaluate its benefits compared with conventional surgical staplers.


Assuntos
Laparoscopia , Fígado , Humanos , Projetos Piloto , Resultado do Tratamento , Fígado/cirurgia , Hepatectomia/métodos , Grampeamento Cirúrgico/métodos , Laparoscopia/métodos , Suturas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA