Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25.330
Filtrar
1.
BMC Anesthesiol ; 24(1): 201, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844869

RESUMO

BACKGROUND: Significant hemodynamic changes occur during liver transplantation, emphasizing the importance of precious and continuous monitoring of cardiac output, cardiac index, and other parameters. Although the monitoring of cardiac output by pulse indicator continuous cardiac output (PiCCO) was statistically homogeneous compared to the clinical gold standard pulmonary artery catheterization (PAC) in previous studies of liver transplantation, there are fewer statistical methods for the assessment of its conclusions, and a lack of comparisons of other hemodynamic parameters (e.g., SVRI, systemic vascular resistance index). Some studies have also concluded that the agreement between PiCCO and PAC is not good enough. Overall, there are no uniform conclusions regarding the agreement between PiCCO and PAC in previous studies. This study evaluates the agreement and trending ability of relevant hemodynamic parameters obtained with PiCCO compared to the clinical gold standard PAC from multiple perspectives, employing various statistical methods. METHODS: Fifty-two liver transplantation patients were included. Cardiac output (CO), cardiac index (CI), SVRI and stroke volume index (SVI) values were monitored at eight time points using both PiCCO and PAC. The results were analyzed by Bland-Altman analysis, Passing-bablok regression, intra-class correlation coefficient (ICC), 4-quadrant plot, polar plot, and trend interchangeability method (TIM). RESULTS: The Bland-Altman analysis revealed high percentage errors for PiCCO: 54.06% for CO, 52.70% for CI, 62.18% for SVRI, and 51.97% for SVI, indicating poor accuracy. While Passing-Bablok plots showed favorable agreement for SVRI overall and during various phases, the agreement for other parameters was less satisfactory. The ICC results confirmed good overall agreement between the two devices across most parameters, except for SVRI during the new liver phase, which showed poor agreement. Additionally, four-quadrant and polar plot analyses indicated that all agreement rate values fell below the clinically acceptable threshold of over 90%, and all angular deviation values exceeded ± 5°, demonstrating that PiCCO is unable to meet the acceptable trends. Using the TIM, the interchangeability rates were found to be quite low: 20% for CO and CI, 16% for SVRI, and 13% for SVI. CONCLUSIONS: Our study revealed notable disparities in absolute values of CO, CI, SVRI and SVI between PiCCO and PAC in intraoperative liver transplant settings, notably during the neohepatic phase where errors were particularly pronounced. Consequently, these findings highlight the need for careful consideration of PiCCO's advantages and disadvantages in liver transplantation scenarios, including its multiple parameters (such as the encompassing extravascular lung water index), against its limited correlation with PAC.


Assuntos
Débito Cardíaco , Cateterismo de Swan-Ganz , Hemodinâmica , Transplante de Fígado , Monitorização Intraoperatória , Transplante de Fígado/métodos , Humanos , Cateterismo de Swan-Ganz/métodos , Débito Cardíaco/fisiologia , Masculino , Pessoa de Meia-Idade , Feminino , Hemodinâmica/fisiologia , Monitorização Intraoperatória/métodos , Idoso , Adulto , Artéria Pulmonar/fisiologia
2.
Cereb Cortex ; 34(6)2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38850217

RESUMO

This study aimed to investigate the effects of high-definition transcranial direct current stimulation on ankle force sense and underlying cerebral hemodynamics. Sixteen healthy adults (8 males and 8 females) were recruited in the study. Each participant received either real or sham high-definition transcranial direct current stimulation interventions in a randomly assigned order on 2 visits. An isokinetic dynamometer was used to assess the force sense of the dominant ankle; while the functional near-infrared spectroscopy was employed to monitor the hemodynamics of the sensorimotor cortex. Two-way analyses of variance with repeated measures and Pearson correlation analyses were performed. The results showed that the absolute error and root mean square error of ankle force sense dropped more after real stimulation than after sham stimulation (dropped by 23.4% vs. 14.9% for absolute error, and 20.0% vs. 10.2% for root mean square error). The supplementary motor area activation significantly increased after real high-definition transcranial direct current stimulation. The decrease in interhemispheric functional connectivity within the Brodmann's areas 6 was significantly correlated with ankle force sense improvement after real high-definition transcranial direct current stimulation. In conclusion, high-definition transcranial direct current stimulation can be used as a potential intervention for improving ankle force sense. Changes in cerebral hemodynamics could be one of the explanations for the energetic effect of high-definition transcranial direct current stimulation.


Assuntos
Tornozelo , Espectroscopia de Luz Próxima ao Infravermelho , Estimulação Transcraniana por Corrente Contínua , Humanos , Feminino , Masculino , Estimulação Transcraniana por Corrente Contínua/métodos , Adulto , Adulto Jovem , Tornozelo/fisiologia , Hemodinâmica/fisiologia , Circulação Cerebrovascular/fisiologia , Córtex Motor/fisiologia
3.
Clin Cardiol ; 47(6): e24277, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38838029

RESUMO

BACKGROUND: Invasive hemodynamics are fundamental in assessing patients with advanced heart failure (HF). Several novel hemodynamic parameters have been studied; however, the relative prognostic potential remains ill-defined. HYPOTHESIS: Advanced hemodynamic parameters provide additional prognostication beyond the standard hemodynamic assessment. METHODS: Patients from the PRognostic Evaluation During Invasive CaTheterization for Heart Failure (PREDICT-HF) registry who underwent right heart catheterization (RHC) were included in the analysis. The primary endpoint was survival to orthotopic heart transplant (OHT) or durable left ventricular assist device (LVAD), or death within 6 months of RHC. RESULTS: Of 846 patients included, 176 (21%) met the primary endpoint. In a multivariate model that included traditional hemodynamic variables, pulmonary capillary wedge pressure (PCWP) (OR: 1.10, 1.04-1.15, p < .001), and cardiac index (CI) (OR: 0.86, 0.81-0.92, p < .001) were shown to be predictive of adverse outcomes. In a separate multivariate model that incorporated advanced hemodynamic parameters, cardiac power output (CPO) (OR: 0.76, 0.71-0.83, p < .001), aortic pulsatility index (API) (OR: 0.94, 0.91-0.96, p < .001), and pulmonary artery pulsatility index (OR: 1.02, 1.00-1.03, p .027) were all significantly associated with the primary outcome. Positively concordant API and CPO afforded the best freedom from the endpoint (94.7%), whilst negatively concordant API and CPO had the worst freedom from the endpoint (61.5%, p < .001). Those with discordant API and CPO had similar freedom from the endpoint. CONCLUSION: The advanced hemodynamic parameters API and CPO are independently associated with death or the need for OHT or LVAD within 6 months. Further prospective studies are needed to validate these parameters and elucidate their role in patients with advanced HF.


Assuntos
Cateterismo Cardíaco , Insuficiência Cardíaca , Hemodinâmica , Sistema de Registros , Humanos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/mortalidade , Masculino , Feminino , Pessoa de Meia-Idade , Hemodinâmica/fisiologia , Medição de Risco/métodos , Prognóstico , Idoso , Fatores de Risco , Pressão Propulsora Pulmonar/fisiologia , Coração Auxiliar , Transplante de Coração , Estudos Retrospectivos , Estados Unidos/epidemiologia , Fatores de Tempo , Valor Preditivo dos Testes , Função Ventricular Esquerda/fisiologia
4.
Brain Cogn ; 179: 106182, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38824809

RESUMO

A single bout of exercise improves executive function (EF) and is a benefit - in part -attributed to an exercise-mediated increase in cerebral blood flow enhancing neural efficiency. Limited work has used an event-related protocol to examine postexercise changes in preparatory phase cerebral hemodynamics for an EF task. This is salient given the neural efficiency hypothesis' assertion that improved EF is related to decreased brain activity. Here, event-related transcranial Doppler ultrasound was used to measure pro- (saccade to target) and antisaccades (saccade mirror-symmetrical target) preparatory phase middle cerebral artery velocity (MCAv) prior to and immediately after 15-min of aerobic exercise. Antisaccades produced longer reaction times (RT) and an increased preparatory phase MCAv than prosaccades - a result attributed to greater EF neural activity for antisaccades. Antisaccades selectively produced a postexercise RT reduction (ps < 0.01); however, antisaccade preparatory phase MCAv did not vary from pre- to postexercise (p=0.53) and did not correlate with the antisaccade RT benefit (p = 0.31). Accordingly, results provide no evidence that improved neural efficiency indexed via functional hyperemia is linked to a postexercise EF behavioural benefit. Instead, results support an evolving view that an EF benefit represents the additive interplay between interdependent exercise-mediated neurophysiological changes.


Assuntos
Circulação Cerebrovascular , Função Executiva , Exercício Físico , Movimentos Sacádicos , Ultrassonografia Doppler Transcraniana , Humanos , Movimentos Sacádicos/fisiologia , Exercício Físico/fisiologia , Masculino , Feminino , Adulto Jovem , Adulto , Circulação Cerebrovascular/fisiologia , Ultrassonografia Doppler Transcraniana/métodos , Função Executiva/fisiologia , Tempo de Reação/fisiologia , Hemodinâmica/fisiologia , Inibição Psicológica , Artéria Cerebral Média/fisiologia , Desempenho Psicomotor/fisiologia
6.
Xenotransplantation ; 31(1): e12841, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38864375

RESUMO

INTRODUCTION: Orthotopic cardiac xenotransplantation has seen notable improvement, leading to the first compassionate use in 2022. However, it remains challenging to define the clinical application of cardiac xenotransplantation, including the back-up strategy in case of xenograft failure. In this regard, the heterotopic thoracic technique could be an alternative to the orthotopic procedure. We present hemodynamic data of heterotopic thoracic pig-to-baboon transplantation experiments, focusing on perioperative xenograft dysfunction and xenograft overgrowth. METHODS: We used 17 genetically modified piglets as donors for heterotopic thoracic xenogeneic cardiac transplantation into captive-bred baboons. In all animals, pressure probes were implanted in the graft's left ventricle and the recipient's ascending aorta and hemodynamic data (graft pressure, aortic pressure and recipient's heart rate) were recorded continuously. RESULTS: Aortic pressures and heart rates of the recipients' hearts were postoperatively stable in all experiments. After reperfusion, three grafts presented with low left ventricular pressure indicating perioperative cardiac dysfunction (PCXD). These animals recovered from PCXD within 48 h under support of the recipient's heart and there was no difference in survival compared to the other 14 ones. After 48 h, graft pressure increased up to 200 mmHg in all 17 animals with two different time-patterns. This led to a progressive gradient between graft and aortic pressure. With increasing gradient, the grafts stopped contributing to cardiac output. Grafts showed a marked weight increase from implantation to explantation. CONCLUSION: The heterotopic thoracic cardiac xenotransplantation technique is a possible method to overcome PCXD in early clinical trials and an experimental tool to get a better understanding of PCXD. The peculiar hemodynamic situation of increasing graft pressure but missing graft's output indicates outflow tract obstruction due to cardiac overgrowth. The heterotopic thoracic technique should be successful when using current strategies of immunosuppression, organ preservation and donor pigs with smaller body and organ size.


Assuntos
Transplante de Coração , Hemodinâmica , Xenoenxertos , Papio , Transplante Heterólogo , Animais , Transplante Heterólogo/métodos , Transplante de Coração/métodos , Suínos , Hemodinâmica/fisiologia , Sobrevivência de Enxerto , Transplante Heterotópico/métodos , Animais Geneticamente Modificados , Rejeição de Enxerto , Humanos
7.
Interv Cardiol Clin ; 13(3): 333-341, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38839167

RESUMO

The surgical pulmonary artery band was first introduced in 1952 and, to this day, can produce challenges in regard to the ideal amount of restriction and the need for reoperations. A transcatheter option may be the ideal solution as it allows for a less-invasive approach for a better hemodynamic assessment and easier re-intervention. To date, multiple approaches have been developed with device modifications to create restrictions to flow, each with advantages and limitations. Continued experience is still necessary to determine the ideal device to use to create an adequate and modifiable level of restriction.


Assuntos
Cardiopatias Congênitas , Artéria Pulmonar , Humanos , Cateterismo Cardíaco/métodos , Desenho de Equipamento , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/fisiopatologia , Hemodinâmica/fisiologia , Artéria Pulmonar/cirurgia
9.
Invest Ophthalmol Vis Sci ; 65(6): 24, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38874963

RESUMO

Purpose: To examine if changes in hemodynamic measures during an orthostatic challenge were associated with progression of age-related macular degeneration (AMD) over a 4-year period in The Irish Longitudinal Study on Ageing. Methods: Participants with AMD who underwent an active stand (AS) test at wave 1 (2009/2010) and retinal photographs at both wave 1 and wave 3 (2014/2015) were included (N = 159: 121 with no AMD progression and 38 with progression). Beat-to-beat hemodynamic data were non-invasively collected using a Finometer MIDI device during the AS at wave 1, recording systolic blood pressure (sBP), diastolic blood pressure (dBP), mean arterial pressure (MAP), and heart rate. Cardiac output, stroke volume, and total peripheral resistance (TPR) were derived from these measures. Baseline characteristics were compared between groups with and without AMD progression. Mixed-effects linear regression models were used to assess the association between changes in hemodynamic parameters during the AS and AMD progression, controlling for known AMD-associated risk factors. Results: At baseline, increasing age and lower dBP were significantly associated with AMD progression. Mixed-effects models for the period between standing and 10 seconds post-stand revealed significant associations with AMD progression with a steeper drop in dBP and a slower drop in TPR. Between 10 and 20 seconds post-stand, AMD progression was significantly associated with less pronounced reduction in heart rate. Conclusions: These observational data suggest that impaired hemodynamic responses within the first 20 seconds of orthostasis may be associated with the progression of AMD.


Assuntos
Envelhecimento , Pressão Sanguínea , Progressão da Doença , Frequência Cardíaca , Degeneração Macular , Humanos , Masculino , Feminino , Idoso , Degeneração Macular/fisiopatologia , Irlanda/epidemiologia , Frequência Cardíaca/fisiologia , Envelhecimento/fisiologia , Pressão Sanguínea/fisiologia , Estudos Longitudinais , Sistema Nervoso Autônomo/fisiopatologia , Idoso de 80 Anos ou mais , Hemodinâmica/fisiologia , Pessoa de Meia-Idade , Fatores de Risco
10.
Adv Exp Med Biol ; 1441: 201-226, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38884713

RESUMO

A well-developed heart is essential for embryonic survival. There are constant interactions between cardiac tissue motion and blood flow, which determine the heart shape itself. Hemodynamic forces are a powerful stimulus for cardiac growth and differentiation. Therefore, it is particularly interesting to investigate how the blood flows through the heart and how hemodynamics is linked to a particular species and its development, including human. The appropriate patterns and magnitude of hemodynamic stresses are necessary for the proper formation of cardiac structures, and hemodynamic perturbations have been found to cause malformations via identifiable mechanobiological molecular pathways. There are significant differences in cardiac hemodynamics among vertebrate species, which go hand in hand with the presence of specific anatomical structures. However, strong similarities during development suggest a common pattern for cardiac hemodynamics in human adults. In the human fetal heart, hemodynamic abnormalities during gestation are known to progress to congenital heart malformations by birth. In this chapter, we discuss the current state of the knowledge of the prenatal cardiac hemodynamics, as discovered through small and large animal models, as well as from clinical investigations, with parallels gathered from the poikilotherm vertebrates that emulate some hemodynamically significant human congenital heart diseases.


Assuntos
Coração , Hemodinâmica , Humanos , Animais , Hemodinâmica/fisiologia , Coração/crescimento & desenvolvimento , Coração/fisiologia , Cardiopatias Congênitas/fisiopatologia
11.
Exp Physiol ; 109(6): 992-1003, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38711207

RESUMO

Young individuals with post-traumatic stress disorder (PTSD) display peripheral vascular and autonomic nervous system dysfunction, two factors potentially stemming from a redox imbalance. It is currently unclear if these aforementioned factors, observed at rest, alter peripheral haemodynamic responses to exercise in this population. This study examined haemodynamic responses to handgrip exercise in young individuals with PTSD following acute antioxidant (AO) supplementation. Thirteen young individuals with PTSD (age 23 ± 3 years), and 13 age- and sex-matched controls (CTRL) participated in the study. Exercise-induced changes to arm blood flow (BF), mean arterial pressure (MAP) and vascular conductance (VC) were evaluated across two workloads of rhythmic handgrip exercise (3 and 6 kg). The PTSD group participated in two visits, consuming either a placebo (PL) or AO prior to their visits. The PTSD group demonstrated significantly lower VC (P = 0.04) across all exercise workloads (vs. CTRL), which was significantly improved following AO supplementation. In the PTSD group, AO supplementation improved VC in participants possessing the lowest VC responses to handgrip exercise, with AO supplementation significantly improving VC responses (3 and 6 kg: P < 0.01) by blunting elevated exercise-induced MAP responses (3 kg: P = 0.01; 6 kg: P < 0.01). Lower VC responses during handgrip exercise were improved following AO supplementation in young individuals with PTSD. AO supplementation was associated with a blunting of exercise-induced MAP responses in individuals with PTSD displaying elevated MAP responses. This study revealed that young individuals with PTSD exhibit abnormal, peripherally mediated exercise responses that may be linked to a redox imbalance.


Assuntos
Antioxidantes , Suplementos Nutricionais , Exercício Físico , Força da Mão , Transtornos de Estresse Pós-Traumáticos , Humanos , Força da Mão/fisiologia , Antioxidantes/administração & dosagem , Masculino , Feminino , Adulto Jovem , Transtornos de Estresse Pós-Traumáticos/fisiopatologia , Exercício Físico/fisiologia , Adulto , Hemodinâmica/efeitos dos fármacos , Hemodinâmica/fisiologia , Pressão Sanguínea/fisiologia , Pressão Sanguínea/efeitos dos fármacos , Fluxo Sanguíneo Regional/fisiologia , Fluxo Sanguíneo Regional/efeitos dos fármacos
12.
Curr Probl Cardiol ; 49(7): 102619, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38723794

RESUMO

OBJECTIVE: This systematic review aims to assess the comparative effectiveness and safety of temporary mechanical circulatory support (MCS) devices in various subgroups of patients with acute cardiogenic shock, providing insights for personalized clinical decision-making. METHODS: We conducted a comprehensive search across major databases to identify studies that reported on the use of temporary MCS devices like TandemHeart, Impella, and VA-ECMO in acute cardiogenic shock. Special attention was given to subgroup analyses based on etiologies of shock, patient demographics, and comorbid conditions. RESULTS: Our analysis revealed that while devices like TandemHeart and Impella offer significant hemodynamic support, their effectiveness and safety profiles vary across different patient subgroups. VA-ECMO demonstrated the highest flow rates and potential for mortality benefits but requires careful management due to associated risks. The lack of randomized controlled trials in specific patient subgroups highlights a gap in the current literature, underscoring the need for targeted research. CONCLUSION: The review underscores the necessity of a personalized approach in selecting temporary MCS devices for patients with acute cardiogenic shock, guided by specific patient characteristics and clinical scenarios. Future research should focus on addressing the identified evidence gaps through well-designed studies that provide robust subgroup-specific data, enabling clinicians to optimize treatment strategies and improve patient outcomes in this critical care context.


Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Choque Cardiogênico , Choque Cardiogênico/terapia , Choque Cardiogênico/mortalidade , Humanos , Coração Auxiliar/efeitos adversos , Oxigenação por Membrana Extracorpórea/métodos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Resultado do Tratamento , Doença Aguda , Hemodinâmica/fisiologia
13.
J Neurol Sci ; 461: 123026, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38723328

RESUMO

BACKGROUND: Orthostatic hypotension (OH) is associated with an increased risk of dementia, potentially attributable to cerebral hypoperfusion. We investigated which patterns and characteristics of OH are related to cognition or to potentially underlying structural brain injury in hemodynamically impaired patients and healthy reference participants. METHODS: Participants with carotid occlusive disease or heart failure, and reference participants from the Heart-Brain Connection Study underwent OH measurements, neuropsychological assessment and brain MRI. We analyzed the association between OH, global cognitive functioning, white matter hyperintensity (WMH) volume and brain parenchymal fraction with linear regression. We stratified by participant group, severity and duration of OH, chronotropic incompetence and presence of orthostatic symptoms. RESULTS: Of 337 participants (mean age 67.3 ± 8.8 years, 118 (35.0%) women), 113 (33.5%) had OH. Overall, presence of OH was not associated with cognitive functioning (ß: -0.12 [-0.24-0.00]), but we did observe worse cognitive functioning in those with severe OH (≥ 30/15 mmHg; ß: -0.18 [-0.34 to -0.02]) and clinically manifest OH (ß: -0.30 [-0.52 to -0.08]). These associations did not differ significantly by OH duration or chronotropic incompetence, and were similar between patient groups and reference participants. Similarly, both severe OH and clinically manifest OH were associated with a lower brain parenchymal fraction, and severe OH also with a somewhat higher WMH volume. CONCLUSIONS: Severe OH and clinically manifest OH are associated with worse cognitive functioning. This supports the notion that specific patterns and characteristics of OH determine its impact on brain health.


Assuntos
Encéfalo , Hipotensão Ortostática , Imageamento por Ressonância Magnética , Humanos , Feminino , Hipotensão Ortostática/diagnóstico por imagem , Hipotensão Ortostática/fisiopatologia , Hipotensão Ortostática/etiologia , Masculino , Idoso , Encéfalo/diagnóstico por imagem , Encéfalo/fisiopatologia , Pessoa de Meia-Idade , Testes Neuropsicológicos , Hemodinâmica/fisiologia , Cognição/fisiologia , Substância Branca/diagnóstico por imagem , Substância Branca/patologia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/complicações
14.
J Electromyogr Kinesiol ; 77: 102887, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38761513

RESUMO

OBJECTIVES: This study examined the effects of acute normoxic and hypoxic exposure on neuromuscular and hemodynamic physiological responses performed during dynamic step muscle actions. METHODS: Thirteen recreationally active men (mean ± SD age: 21.2 ± 2.9 yrs) performed dynamic leg extensions unilaterally under Normoxic (FiO2 = 21 %) and Hypoxic (FiO2 = 13 %) conditions in a randomized order at 20 %, 40 %, 60 %, 80 %, and 100 % of their maximal strength. Electromyographic (EMG) amplitude, EMG frequency, (Oxygenated and Deoxygenated hemoglobin; OxyHb, DeoxyHb), Total hemoglobin (TotalHb), and skeletal muscle tissue oxygenation status (StO2) were measured from the vastus lateralis during all contractions. RESULTS: There were no detectable differences in the neuromuscular responses between normoxia and hypoxia for EMG amplitude (p = 0.37-0.74) and frequency (p = 0.17-0.83). For EMG amplitude there were general increases with intensity (p < 0.01-0.03). EMG frequency remained similar from 20% to 80% and then increased at 100 % effort (p = 0.02). There was no significant difference in patterns of responses for OxyHb (p = 0.870) and TotalHb (p = 0.200) between normoxia and hypoxia. StO2 (p = 0.028) decreased and DeoxyHb (p = 0.006) increased under hypoxia compared to normoxia during dynamic step muscle actions performed in a randomized order. CONCLUSION: Unlike fatigue, acute hypoxemia in an unfatigued state does not impact the localized neuromuscular responses, but minimally impacts the hemodynamic responses.


Assuntos
Eletromiografia , Hemodinâmica , Hipóxia , Músculo Esquelético , Humanos , Masculino , Hipóxia/fisiopatologia , Adulto Jovem , Músculo Esquelético/fisiopatologia , Músculo Esquelético/fisiologia , Hemodinâmica/fisiologia , Treinamento Resistido/métodos , Perna (Membro)/fisiologia , Contração Muscular/fisiologia , Consumo de Oxigênio/fisiologia , Adulto
15.
Sci Rep ; 14(1): 11287, 2024 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760449

RESUMO

Spectrum power analysis in the low frequency oscillations (LFO) region of functional near infrared spectroscopy (fNIRS) is a promising method to deliver information about brain activation and therefore might be used for prognostication in patients with disorders of consciousness in the neurocritical care unit alongside with established methods. In this study, we measure the cortical hemodynamic response measured by fNIRS in the LFO region following auditory and somatosensory stimulation in healthy subjects. The significant hemodynamic reaction in the contralateral hemisphere correlation with the physiologic electric response suggests neurovascular coupling. In addition, we investigate power spectrum changes in steady state measurements of cerebral death patients and healthy subjects in the LFO region, the frequency of the heartbeat and respiration. The spectral power within the LFO region was lower in the patients with cerebral death compared to the healthy subjects, whereas there were no differences in spectral power for physiological activities such as heartbeat and respiration rate. This finding indicates the cerebral origin of our low frequency measurements. Therefore, LFO measurements are a potential method to detect brain activation in patients with disorders of consciousness and cerebral death. However, further studies in patients are needed to investigate its potential clinical use.


Assuntos
Morte Encefálica , Acoplamento Neurovascular , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Masculino , Feminino , Adulto , Acoplamento Neurovascular/fisiologia , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Morte Encefálica/fisiopatologia , Pessoa de Meia-Idade , Hemodinâmica/fisiologia , Idoso , Encéfalo/fisiopatologia , Encéfalo/fisiologia , Encéfalo/diagnóstico por imagem , Frequência Cardíaca/fisiologia
16.
PLoS One ; 19(5): e0302828, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38722930

RESUMO

Cupping therapy is a popular intervention for improving muscle recovery after exercise although clinical evidence is weak. Previous studies demonstrated that cupping therapy may improve microcirculation of the soft tissue to accelerate tissue healing. However, it is unclear whether the cupping size could affect the spatial hemodynamic response of the treated muscle. The objective of this study was to use 8-channel near-infrared spectroscopy to assess this clinical question by assessing the effect of 3 cupping sizes (35, 40, and 45 mm in inner diameter of the circular cup) under -300 mmHg for 5 min on the muscle hemodynamic response from the area inside and outside the cup, including oxyhemoglobin and deoxy-hemoglobin in 18 healthy adults. Two-way factorial design was used to assess the interaction between the cupping size (35, 40, and 45 mm) and the location (inside and outside the cup) and the main effects of the cupping size and the location. The two-way repeated measures ANOVA demonstrated an interaction between the cupping size and the location in deoxy-hemoglobin (P = 0.039) but no interaction in oxyhemoglobin (P = 0.100), and a main effect of the cup size (P = 0.001) and location (P = 0.023) factors in oxyhemoglobin. For the cupping size factor, the 45-mm cup resulted in a significant increase in oxyhemoglobin (5.738±0.760 µM) compared to the 40-mm (2.095±0.312 µM, P<0.001) and 35-mm (3.134±0.515 µM, P<0.01) cup. Our findings demonstrate that the cupping size and location factors affect the muscle hemodynamic response, and the use of multi-channel near-infrared spectroscopy may help understand benefits of cupping therapy on managing musculoskeletal impairment.


Assuntos
Hemodinâmica , Músculo Esquelético , Oxiemoglobinas , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Masculino , Hemodinâmica/fisiologia , Feminino , Adulto , Músculo Esquelético/fisiologia , Músculo Esquelético/irrigação sanguínea , Oxiemoglobinas/metabolismo , Oxiemoglobinas/análise , Ventosaterapia/métodos , Adulto Jovem , Hemoglobinas/metabolismo
17.
Pediatr Neurol ; 156: 72-78, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38733857

RESUMO

BACKGROUND: Neonates with congenital heart disease (CHD) have smaller brain volume at birth. High rates of placental vascular malperfusion lesions may play a role in disrupted brain development. METHODS: This is a single-center retrospective cohort study of infants born between 2010 and 2019 who were diagnosed with a major cardiac defect requiring surgery in the first year of life. Doppler ultrasound RI of the middle cerebral artery (MCA) and anterior cerebral artery were calculated within the first 72 hours of life. Placentas were evaluated using a standardized approach. RESULTS: Over the study period, there were 52 patients with hypoplastic left heart syndrome (HLHS), 22 with single-ventricle right ventricular outflow tract obstruction (SV-RVOTO), 75 with a two-ventricle cardiac defect (2V), and 25 with transposition of the great arteries (TGA). MCA Doppler RI were significantly higher for all subgroups of CHD compared with control subjects (0.68 ± 0.11 in control subjects compared with 0.78 ± 0.13 in HLHS, P = 0.03; 0.77 ± 0.10 in SV-RVOTO, P = 0.002; 0.78 ± 0.13 in 2V, P = 0.03; and 0.80 ± 0.14 in TGA; P = 0.001) with the highest average MCA RI in the TGA group. In subgroup analyses, placental fetal vascular malperfusion in the 2V group was associated with higher MCA RI, but this relationship was not present in other subgroups, nor in regards to maternal vascular malperfusion. CONCLUSIONS: Major forms of CHD are associated with significantly higher cerebral artery RI postnatally, but placental vascular malperfusion lesions may not contribute to this hemodynamic adaptation.


Assuntos
Circulação Cerebrovascular , Cardiopatias Congênitas , Artéria Cerebral Média , Humanos , Feminino , Estudos Retrospectivos , Recém-Nascido , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/diagnóstico por imagem , Gravidez , Masculino , Artéria Cerebral Média/diagnóstico por imagem , Artéria Cerebral Média/fisiopatologia , Circulação Cerebrovascular/fisiologia , Hemodinâmica/fisiologia , Placenta/irrigação sanguínea , Placenta/diagnóstico por imagem , Placenta/patologia , Placenta/fisiopatologia , Artéria Cerebral Anterior/diagnóstico por imagem , Artéria Cerebral Anterior/fisiopatologia , Artéria Cerebral Anterior/patologia
18.
Khirurgiia (Mosk) ; (5): 95-100, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38785244

RESUMO

A personalized approach with attention to anamnesis and specific symptoms is necessary in patients with internal carotid artery tortuosity. Neuroimaging (especially before elective surgery) or functional stress tests following ultrasound of supra-aortic vessels may be necessary depending on medical history and complaints. In addition to standard Doppler ultrasound, these patients should undergo rotational and orthostatic transformation tests. We analyze changes in shape and hemodynamic parameters within the tortuosity area in various body positions. This is especially valuable for patients with concomitant carotid artery stenosis. The article presents a clinical case illustrating the importance of such approach.


Assuntos
Artéria Carótida Interna , Estenose das Carótidas , Humanos , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/anormalidades , Artéria Carótida Interna/fisiopatologia , Estenose das Carótidas/fisiopatologia , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico , Estenose das Carótidas/cirurgia , Masculino , Feminino , Pessoa de Meia-Idade , Ultrassonografia Doppler/métodos , Hemodinâmica/fisiologia , Aterosclerose/complicações , Aterosclerose/diagnóstico , Aterosclerose/fisiopatologia , Malformações Vasculares/diagnóstico , Malformações Vasculares/complicações , Malformações Vasculares/fisiopatologia , Idoso , Artérias/anormalidades , Instabilidade Articular , Dermatopatias Genéticas
19.
Andes Pediatr ; 95(2): 202-212, 2024 Apr.
Artigo em Espanhol | MEDLINE | ID: mdl-38801369

RESUMO

Sepsis is one of the main causes of admission to Intensive Care Units (ICU). The hemodynamic objectives usually sought during the resuscitation of the patient in septic shock correspond to macrohemodynamic parameters (heart rate, blood pressure, central venous pressure). However, persistent alterations in microcirculation, despite the restoration of macrohemodynamic parameters, can cause organ failure. This dissociation between the macrocirculation and microcirculation originates the need to evaluate organ tissue perfusion, the most commonly used being urinary output, lactatemia, central venous oxygen saturation (ScvO2), and veno-arterial pCO2 gap. Because peripheral tissues, such as the skin, are sensitive to disturbances in perfusion, noninvasive monitoring of peripheral circulation, such as skin temperature gradient, capillary refill time, mottling score, and peripheral perfusion index may be helpful as early markers of the existence of systemic hemodynamic alterations. Peripheral circulation monitoring techniques are relatively easy to interpret and can be used directly at the patient's bedside. This approach can be quickly applied in the intra- or extra-ICU setting. The objective of this narrative review is to analyze the various existing tissue perfusion markers and to update the evidence that allows guiding hemodynamic support in a more individualized therapy for each patient.


Assuntos
Hemodinâmica , Microcirculação , Humanos , Criança , Microcirculação/fisiologia , Hemodinâmica/fisiologia , Choque Séptico/terapia , Choque Séptico/fisiopatologia , Choque Séptico/diagnóstico , Monitorização Fisiológica/métodos , Monitorização Hemodinâmica/métodos , Doença Aguda , Sepse/diagnóstico , Sepse/terapia , Sepse/fisiopatologia , Biomarcadores/sangue
20.
Alzheimers Dement ; 20(6): 4032-4042, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38700095

RESUMO

INTRODUCTION: Delirium is associated with mortality and new onset dementia, yet the underlying pathophysiology remains poorly understood. Development of imaging biomarkers has been difficult given the challenging nature of imaging delirious patients. Diffuse optical tomography (DOT) offers a promising approach for investigating delirium given its portability and three-dimensional capabilities. METHODS: Twenty-five delirious and matched non-delirious patients (n = 50) were examined using DOT, comparing cerebral oxygenation and functional connectivity in the prefrontal cortex during and after an episode of delirium. RESULTS: Total hemoglobin values were significantly decreased in the delirium group, even after delirium resolution. Functional connectivity between the dorsolateral prefrontal cortex and dorsomedial prefrontal cortex was strengthened post-resolution compared to during an episode; however, this relationship was still significantly weaker compared to controls. DISCUSSION: These findings highlight DOT's potential as an imaging biomarker to measure impaired cerebral oxygenation and functional dysconnectivity during and after delirium. Future studies should focus on the role of cerebral oxygenation in delirium pathogenesis and exploring the etiological link between delirium and dementias. HIGHLIGHTS: We developed a portable diffuse optical tomography (DOT) system for bedside three-dimensional functional neuroimaging to study delirium in the hospital. We implemented a novel DOT task-focused seed-based correlation analysis. DOT revealed decreased cerebral oxygenation and functional connectivity strength in the delirium group, even after resolution of delirium.


Assuntos
Delírio , Tomografia Óptica , Humanos , Tomografia Óptica/métodos , Delírio/diagnóstico por imagem , Delírio/fisiopatologia , Masculino , Feminino , Idoso , Córtex Pré-Frontal/diagnóstico por imagem , Hemodinâmica/fisiologia , Circulação Cerebrovascular/fisiologia , Mapeamento Encefálico , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA