Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 765
Filtrar
1.
J Chromatogr A ; 1732: 465200, 2024 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-39096780

RESUMO

A covalent organic framework (COF) was gown on porous silica with 1,3,5-tri(4-aminophenyl)benzene and 2,5-divinyl-1,4-phenyldiformaldehyde as monomers, and two ionic liquids were grafted to COF by a click reaction. The materials before and after the modification of ionic liquids were separately packed into solid-phase extraction columns (10 × 4.6 mm, i.d.), which were coupled with liquid chromatography to construct online analysis systems. The extraction mechanisms of polycyclic aromatic hydrocarbons, bisphenols, diphenylalkanes and benzoic acids were investigated on these materials. There were π-π, hydrogen-bond and electrostatic interactions on ionic liquid-functionalized sorbents. After the comparison among these materials, the best sorbent was used, and the analytical method was established and successfully applied to the detection of some estrogens from actual samples. For the analytical method, the detection limit was as low as 0.005 µg L-1, linear range was as wide as 0.017-10.0 µg L-1, and enrichment ratio was as high as 3635. The recoveries in actual samples were 70 %-129 %.


Assuntos
Líquidos Iônicos , Limite de Detecção , Dióxido de Silício , Extração em Fase Sólida , Líquidos Iônicos/química , Extração em Fase Sólida/métodos , Dióxido de Silício/química , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/química , Estruturas Metalorgânicas/química , Adsorção , Estrogênios/isolamento & purificação , Estrogênios/análise , Estrogênios/química , Porosidade , Cromatografia Líquida de Alta Pressão/métodos
2.
J Chromatogr A ; 1733: 465258, 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39167883

RESUMO

A hybrid organic monolithic column made of poly(lauryl methacrylate-co-1,6-hexanediol dimethacrylate) and the metal-organic framework MIL-68(Al) was prepared for the first time. The column was used in capillary liquid chromatography, both in isocratic and gradient elution modes. Separation performance towards small molecules of different chemical nature (polycyclic aromatic hydrocarbons, alkylbenzenes, phenols, etc.) was studied. Monte Carlo simulations were made to both select the proper precursors to obtain empty metal-organic framework micropores in the monolithic polymer and also, to analyze the potential free access of the studied analytes into the micropores (necessary to improve mass transfer and column efficiency). The hereby synthesized metal-organic framework microcrystals allowed obtaining homogeneous hybrid monolithic columns. Adding of MIL-68(Al) (1030 m2 g-1 BET specific surface area) increased the surface area from 3.9 m2 g-1 for the parent monolith to 18.2 m2 g-1 for the hybrid column containing 8 mg mL-1 of the microcrystals. Chromatographic performance of this new column was evaluated by studying retention factors, resolution, and plate counts at room temperature. Different compounds, not completely resolved in the parent monolith, were partially or completely separated after metal-organic framework addition. Using the monolithic column with only 2 mg mL-1 of MIL-68(Al), five alkylbenzenes were completely separated with very symmetrical peak shapes, resolution factors up to 3.60 and plate counts of 4300 plates m-1 for n-hexylbenzene. This value is higher than those obtained by other authors who used organic monolithic columns with embedded metal-organic frameworks to perform separations at room temperature. Additionally, nine polycyclic aromatic hydrocarbons were partially or completely resolved in gradient elution mode. The hybrid monolithic columns exhibited very good intra-day (%RSD=1.9), inter-day (%RSD=2.6), and column-to-column (%RSD=4.3) reproducibility values. Easy and fast column preparation, and versatility to efficiently separate several compounds of different chemical nature in isocratic and gradient mode, makes this new hybrid column a very good option for the analysis of small molecules in capillary (or nano) HPLC.


Assuntos
Estruturas Metalorgânicas , Hidrocarbonetos Policíclicos Aromáticos , Cromatografia Líquida de Alta Pressão/métodos , Estruturas Metalorgânicas/química , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/química , Método de Monte Carlo , Fenóis/isolamento & purificação , Fenóis/análise , Fenóis/química , Porosidade
3.
J Chromatogr A ; 1733: 465257, 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39178655

RESUMO

This work describes the development of a new automated parallel dispersive tip microextraction method (Au-Pa-DPX) for the determination of eleven polycyclic aromatic hydrocarbons (PAHs) in four samples of Brazilian sugarcane spirit beverages, with separation and detection done by the HPLC-DAD. The results obtained with the Au-Pa-DPX approach were also compared with those obtained via the conventional parallel manual DPX method with the same samples and optimized extraction process. Desorption solvent and cycles of desorption, cleaning and extraction were optimized using response surface methodology and univariate approaches. For the Au-Pa-DPX method, the coefficient of determination (R2) ranged from 0.9948 to 0.9997. The limits of detection and quantification were all 0.303 µg l-1 and 1.00 µg l-1, respectively. Interday and intraday precision ranged from 7.6 % to 31.7 % and 0.40 % to 15.8 %, respectively. For the manual parallel DPX method, the interday and intraday precision ranged from 8.2 % to 38.1 % and 5.40 % to 18.7 %, respectively. The relative recovery values obtained with the proposed method ranged from 53.29 to 124.94 %. The enrichment factors ranged from 15.13 to 22.35. The sum of PAH concentrations in the four samples ranged from undetected to 25.58 µg l-1. These results, when correlated to other methods, highlight the gains in regards to precision obtained with the automated apparatus. Furthermore, when compared to other methods from the literature, it is an interesting green alternative for the determination of these analytes and this sample, with high throughput (4.67 min per sample), low consumption of solvents and samples, generating less waste and reducing health risks to the analyst.


Assuntos
Limite de Detecção , Hidrocarbonetos Policíclicos Aromáticos , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Cromatografia Líquida de Alta Pressão/métodos , Saccharum/química , Microextração em Fase Líquida/métodos , Bebidas Alcoólicas/análise , Reprodutibilidade dos Testes , Bebidas/análise
4.
J Chromatogr A ; 1733: 465259, 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39178659

RESUMO

Aluminum-based metal organic framework composite containing ionic liquid was prepared and used as sorbent for extraction of sixteen polycyclic aromatic hydrocarbons in list of priority pollutants of United States Environmental Protection Agency before their analysis by gas chromatography/mass spectrometry. The dispersive micro solid-phase extraction method, known as a simple and fast method, was preferred as the extraction method. The optimized parameter conditions were 5 mL of sample solution, 10 min sonication by ultrasonic bath, 30 mg of sorbent, 30 °C extraction temperature, 0.1 mL of hexane as elution solvent with 5 min elution time. The suggested method presented that limit of detection and limit of quantification were in the range of 0.01-0.10 µg l-1, and 0.04-0.33 µg L-1, respectively. The intra-day and inter-day repeatability were within the ranges of 1.18-4.88 % and 1.02-5.06 %, respectively. The recoveries for polycyclic aromatic hydrocarbons in peach juice, cherry juice, tap water and rain water samples were obtained in the range of 84.9-99.9 % for spiked 5, 50 and 100 µg l-1 standard polycyclic aromatic hydrocarbons solution.


Assuntos
Sucos de Frutas e Vegetais , Cromatografia Gasosa-Espectrometria de Massas , Líquidos Iônicos , Limite de Detecção , Estruturas Metalorgânicas , Hidrocarbonetos Policíclicos Aromáticos , Poluentes Químicos da Água , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Líquidos Iônicos/química , Sucos de Frutas e Vegetais/análise , Estruturas Metalorgânicas/química , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Sonicação , Microextração em Fase Sólida/métodos , Reprodutibilidade dos Testes
5.
J Chromatogr A ; 1733: 465249, 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39178658

RESUMO

Geometric isomers tend to have similar polarities and differ only in molecular shape. Vigorously developing new stationary phases to meet the requirements for the separation of isomers that have similar physicochemical properties is still an urgent topic in separation science. Poly (arylene ether)-based dendrimers are known for their multifunctional branched peripheral structures and high self-assembly properties. In this paper, two amphiphilic dendritic organic small molecule gelling agents based on poly (aryl ether), PAE-ANT and PAE-PA, were prepared and conjugated to the silica surface. SiO2@PAE-ANT and SiO2@PAE-PA were used as HPLC stationary phases for the separation of non-polar shape-restricted isomers. Both stationary phases have very high molecular shape selectivity for isomers such as polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), tocopherols and carotenoids. Separation of cis-trans geometric isomers such as diethylstilbestrol and polar compounds such as monosubstituted benzenes and anilines can also be achieved. These two columns offer more flexible selectivity and higher separation performance than commercial C18 and phenyl columns. There is a difference in molecular shape selectivity between the two stationary phases for the same analyte test probes. SiO2@PAE-ANT showed slightly better linear selectivity for non-polar shape-restricted isomers compared to SiO2@PAE-PA with Janus-type PAE-PA bonding phase. This separation behavior may be attributed to the ordered spatial structure formed by the gel factor on the surface of the stationary phase and the combined effect of multiple weak interaction centers (hydrophobic, hydrophilic, hydrogen bonding and π-π interactions). It was also possible to separate nucleoside and nucleobase strongly polar compounds well in the HILIC mode, suggesting that hydrophilic groups in PAE-ANT and PAE-PA are involved in the interactions, reflecting their amphiphilic nature. The results show that the ordered gelation of dendritic organic small molecule gelators on the SiO2 surface, along with multiple carbonyl-π, π-π and other interactions, play a crucial role in the separating shape-restricted isomers. The integrated and ordered functional groups serve as the primary driving force behind the exceptionally high molecular shape selectivity of SiO2@PAE-ANT and SiO2@PAE-PA phases. Alterations in the structure of dendritic organic small molecule gelators can impact both molecular orientation and recognition ability, while changes in the type of functional groups influences the separation mechanism of shape-restricted isomers.


Assuntos
Dendrímeros , Dióxido de Silício , Dióxido de Silício/química , Cromatografia Líquida de Alta Pressão/métodos , Isomerismo , Dendrímeros/química , Hidrocarbonetos Policíclicos Aromáticos/química , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Bifenilos Policlorados/química , Bifenilos Policlorados/análise , Bifenilos Policlorados/isolamento & purificação , Carotenoides/química , Carotenoides/análise , Carotenoides/isolamento & purificação , Tensoativos/química
6.
Anal Chim Acta ; 1321: 343018, 2024 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-39155102

RESUMO

BACKGROUND: Food safety has become an essential aspect of public concern and there are lots of detection means. Liquid chromatography plays a dominating role in food safety inspection because of its high separation efficiency and reproducibility. However, with the increasing complexity of real samples and monitoring requirements, conventional single-mode chromatography would require frequent column replacement and cannot separate different kinds of analytes on a single column simultaneously, which is costly and time-consuming. There is a great need for fabricating mixed-mode stationary phases and validating the feasibility of employing mixed-mode stationary phases for food safety inspection. RESULTS: This work fabricated multifunctional stationary phases for liquid chromatography to determine diverse food additives under the mixed mode of RPLC/HILIC/IEC. Two dicationic ionic liquid silanes were synthesized and bonded onto the silica gel surface. The functionalized silica was characterized by Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, and elemental analysis. Both columns provide satisfactory separation performance towards 6 hydrophilic nucleosides, 4 hydrophobic polycyclic aromatic hydrocarbons, and 5 anions. Great repeatability of retention (RSD <0.1 %) and column efficiency (100330 plate/m) were obtained. Thermomechanical analysis and linear solvation energy relationship investigated the retention mechanism. Finally, the better in two prepared columns was employed to separate and determine the contents of NO2- and NO3- in vegetables(highest 4906 mg kg-1 NO3- in spinach), preservatives in bottled beverages (180.8 mg kg-1 sodium benzoate in soft drink), and melamine in milk with satisfactory performance and recovery rates ranging from 96.4 % to 105.6 %. SIGNIFICANCE: This work developed a novel scheme for preparing mixed-mode stationary phases by dicationic ionic liquid which provides great separation selectivity. Most importantly, this work proved the superiority of employing mixed-mode stationary phases for food safety inspection, which might avoid high-cost and frequent changes of columns and chromatography systems in the near future.


Assuntos
Aditivos Alimentares , Líquidos Iônicos , Dióxido de Silício , Líquidos Iônicos/química , Dióxido de Silício/química , Aditivos Alimentares/análise , Aditivos Alimentares/isolamento & purificação , Cromatografia Líquida/métodos , Nucleosídeos/isolamento & purificação , Nucleosídeos/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Ânions/análise , Ânions/isolamento & purificação , Ânions/química , Silanos/química
7.
Sci Rep ; 14(1): 15054, 2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-38956159

RESUMO

This study aimed to develop a highly efficient nanocomposite composed of magnetic chitosan/molybdenum disulfide (CS/MoS2/Fe3O4) for the removal of three polycyclic aromatic hydrocarbons (PAHs)-pyrene, anthracene, and phenanthrene. Novelty was introduced through the innovative synthesis procedure and the utilization of magnetic properties for enhanced adsorption capabilities. Additionally, the greenness of chitosan as a sorbent component was emphasized, highlighting its biodegradability and low environmental impact compared to traditional sorbents. Factors influencing PAH adsorption, such as nanocomposite dosage, initial PAH concentration, pH, and contact time, were systematically investigated and optimized. The results revealed that optimal removal efficiencies were attained at an initial PAH concentration of 150 mg/L, a sorbent dose of 0.045 g, pH 6.0, and a contact time of 150 min. The pseudo-second-order kinetic model exhibited superior fitting to the experimental data, indicating an equilibrium time of approximately 150 min. Moreover, the equilibrium adsorption process followed the Freundlich isotherm model, with kf and n values exceeding 7.91 mg/g and 1.20, respectively. Remarkably, the maximum absorption capacities for phenanthrene, anthracene, and pyrene on the sorbent were determined as 217 mg/g, 204 mg/g, and 222 mg/g, respectively. These findings underscore the significant potential of the CS/MoS2/Fe3O4 nanocomposite for efficiently removing PAHs from milk and other dairy products, thereby contributing to improved food safety and public health.


Assuntos
Quitosana , Dissulfetos , Leite , Molibdênio , Nanocompostos , Hidrocarbonetos Policíclicos Aromáticos , Dissulfetos/química , Nanocompostos/química , Quitosana/química , Hidrocarbonetos Policíclicos Aromáticos/química , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Molibdênio/química , Leite/química , Animais , Adsorção , Cinética , Concentração de Íons de Hidrogênio
8.
Food Chem ; 459: 140452, 2024 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-39024871

RESUMO

Polycyclic aromatic hydrocarbons (PAHs) are commonly found in various environmental matrices and have received significant attention due to their toxic effects on ecosystems and environmental health. In this study, a specific magnetic composite material derived from MXene, known as phenyl-functionalized NiFe2O4@Ti3C2TX, was designed and synthesized using a simple method. This composite material was used to develop an effective magnetic solid-phase extraction (MSPE) method for enriching trace polycyclic aromatic hydrocarbons (PAHs) in tea and coffee samples. The eluted PAHs were analyzed via gas chromatography-tandem mass spectrometry. Under optimal conditions, this method exhibited excellent linear relationships for 16 PAHs within the ranges of 0.001-25 and 0.0005-25 µg/L, with correlation coefficients exceeding 0.9979. The limits of detection for the target PAHs ranged from 0.1 to 0.3 ng/L. The effectiveness of the proposed method was evaluated by analyzing tea and coffee samples, and the satisfactory spiked recoveries of PAHs ranged from 84.5% to 112.6%.


Assuntos
Café , Contaminação de Alimentos , Hidrocarbonetos Policíclicos Aromáticos , Extração em Fase Sólida , Chá , Chá/química , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Hidrocarbonetos Policíclicos Aromáticos/química , Café/química , Extração em Fase Sólida/métodos , Contaminação de Alimentos/análise , Níquel/química , Níquel/análise , Níquel/isolamento & purificação , Compostos Férricos/química , Cromatografia Gasosa-Espectrometria de Massas , Limite de Detecção
9.
J Chromatogr A ; 1730: 465134, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-38959655

RESUMO

The unique properties of pillar[5]arene, including hydrophobic cavities, π-π conjugated and easy modification, make it a promising candidate as stationary phase for HPLC. Herein, we fabricated a novel propanediamine modified pillar[5]arene bonded silica as the stationary phase (PDA-BP5S) for reversed-phase liquid chromatography (RPLC). Benefiting from the significant hydrophobicity, π-π conjugative, p-π effect, and hydrogen bonding, the PDA-BP5S packed column showed high separation performance of versatile analytes involving polycyclic aromatic hydrocarbons, alkyl benzenes, phenols, arylamine, phenylethane/styrene/ phenylacetylene, toluene/m-xylene/mesitylene, halobenzenes, benzenediol and nitrophenol isomers. Especially, the separation of halobenzenes appeared to be controlled by both the size of the halogen substituents and the strength of the noncovalent bonding interactions, which was further confirmed by molecular dynamics simulation. The satisfactory separation and repeatability revealed the promising prospects of amine-pillar[5]arene-based stationary phase for RPLC.


Assuntos
Calixarenos , Cromatografia de Fase Reversa , Interações Hidrofóbicas e Hidrofílicas , Cromatografia de Fase Reversa/métodos , Calixarenos/química , Simulação de Dinâmica Molecular , Compostos de Amônio Quaternário/química , Cromatografia Líquida de Alta Pressão/métodos , Dióxido de Silício/química , Ligação de Hidrogênio , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/química
10.
J Chromatogr A ; 1730: 465098, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-38901295

RESUMO

The epoxy propanol molecular cage bonded silica stationary phase, RCC3-GLD@silica, synthesized through the ring-opening reaction of secondary amine with epoxy propanol using RCC3-R as the scaffold unit, was successfully prepared as confirmed by infrared spectroscopy, thermogravimetric analysis, and nitrogen adsorption-desorption characterization. This stationary phase demonstrated excellent separation performance in both reversed-phase and hydrophilic chromatography modes, effectively separating a wide variety of compounds including alkylbenzenes, polycyclic aromatic hydrocarbons, phenols, anilines, sulfonamides, nucleosides, amino acids, sugars, and acids. The development of RCC3-GLD@silica benefits from the synergistic effects of its hydrophobic and hydrophilic actions, as evidenced by the U-shaped characteristic of the retention factor for nucleoside compounds with changes in the aqueous content of the mobile phase, further confirming the simultaneous presence of reversed-phase and hydrophilic chromatography mechanisms. Not only did this stationary phase successfully separate 33 compounds in reversed-phase chromatography mode, but it also separated 54 compounds in hydrophilic interaction chromatography mode, showcasing its broad separation capability from weakly polar to strongly polar compounds on a single chromatographic column. This indicates a wide application prospect in the field of chromatographic analysis.


Assuntos
Cromatografia de Fase Reversa , Interações Hidrofóbicas e Hidrofílicas , Nucleosídeos , Dióxido de Silício , Dióxido de Silício/química , Cromatografia de Fase Reversa/métodos , Nucleosídeos/isolamento & purificação , Nucleosídeos/química , Compostos de Epóxi/química , Aminoácidos/isolamento & purificação , Aminoácidos/química , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Hidrocarbonetos Policíclicos Aromáticos/química , Fenóis/isolamento & purificação , Fenóis/química , Cromatografia Líquida de Alta Pressão/métodos
11.
J Chromatogr A ; 1730: 465104, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-38905947

RESUMO

For the first time, a method for the simultaneous analysis of fifteen polycyclic aromatic hydrocarbons (PAHs), including light and heavy PAHs, in açaí-based food products (AFPs) was developed using vacuum-assisted sorbent extraction (VASE) combined with gas chromatography-mass spectrometry (GC-MS). The method requires no organic solvents and is amenable to full automation. To achieve optimal analytical extraction conditions, VASE parameters including stirring rate, extraction time, desorption temperature, desorption time, preheat time, and preheat temperature were optimized using sequential multivariate optimization. The method was validated and yielded limits of quantification below 1 µg kg-1 for all analytes, with recoveries ranging from 65 % to 112 % and good precision (≤11 % relative standard deviation). Additionally, the greenness and practical aspects of the method were investigated using the Green Analytical Procedure Index (GAPI), eco-scale, and the Blue Applicability Grade Index (BAGI), respectively. The VASE-GC-MS approach is suitable for routine analysis and exhibits characteristics of a green analytical method. No PAHs were detected above the limits of detection in thirty samples of AFPs.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas , Limite de Detecção , Hidrocarbonetos Policíclicos Aromáticos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Vácuo , Extração em Fase Sólida/métodos , Contaminação de Alimentos/análise , Química Verde/métodos , Análise de Alimentos/métodos , Reprodutibilidade dos Testes
12.
Talanta ; 277: 126418, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38879948

RESUMO

Polycyclic aromatic compounds (PACs) encompass a wide variety of organic analytes that have mutagenic and carcinogenic potentials for human health and are recalcitrant in the environment. Evaluating PACs levels in fuel (e.g., gasoline and diesel), food (e.g., grilled meat, fish, powdered milk, fruits, honey, and coffee) and environmental (e.g., industrial effluents, water, wastewater and marine organisms) samples are critical to determine the risk that these chemicals pose. Deep eutectic solvents (DES) have garnered significant attention in recent years as a green alternative to traditional organic solvents employed in sample preparation. DES are biodegradable, have low toxicities, ease of synthesis, low cost, and a remarkable ability to extract PACs. However, no comprehensive assessment of the use of DESs for extracting PACs from fuel, food and environmental samples has been performed. This review focused on research involving the utilization of DESs to extract PACs in matrices such as PAHs in environmental samples, NSO-HET in fuels, and bisphenols in foods. Chromatographic methods, such as gas chromatography (GC) and high-performance liquid chromatography (HPLC), were also revised, considering the sensibility to quantify these compound types. In addition, the characteristics of DES and advantages and limitations for PACs in the context of green analytical chemistry principles (GAC) and green profile based on metrics provide perspective and directions for future development.


Assuntos
Solventes Eutéticos Profundos , Hidrocarbonetos Policíclicos Aromáticos , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Hidrocarbonetos Policíclicos Aromáticos/química , Solventes Eutéticos Profundos/química , Análise de Alimentos/métodos , Contaminação de Alimentos/análise
13.
Anal Chim Acta ; 1306: 342609, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38692788

RESUMO

BACKGROUND: Accurate quantitative analysis of small molecule metabolites in biological samples is of great significance. Hydroxypolycyclic aromatic hydrocarbons (OH-PAHs) are metabolic derivatives of emerging pollutants, reflecting exposure to polycyclic aromatic hydrocarbons (PAHs). Macromolecules such as proteins and enzymes in biological samples will interfere with the accurate quantification of OH-PAHs, making direct analysis impossible, requiring a series of complex treatments such as enzymatic hydrolysis. Therefore, the development of matrix-compatible fiber coatings that can exclude macromolecules is of great significance to improve the ability of solid-phase microextraction (SPME) technology to selectively quantify small molecules in complex matrices and achieve rapid and direct analysis. RESULTS: We have developed an innovative coating with a stable macromolecular barrier using electrospinning and flexible filament winding (FW) technologies. This coating, referred to as the hollow fibrous covalent organic framework@polyionic liquid (F-COF@polyILs), demonstrates outstanding conductivity and stability. It accelerates the adsorption equilibrium time (25 min) for polar OH-PAHs through electrically enhanced solid-phase microextraction (EE-SPME) technology. Compared to the powder form, F-COF@polyILs coating displays effective non-selective large-size molecular sieving. Combining gas chromatography-tandem triple quadrupole mass spectrometry (GC-MS/MS), we have established a simple, efficient quantitative analysis method for OH-PAHs with a low detection limit (0.008-0.05 ng L-1), wide linear range (0.02-1000 ng L-1), and good repeatability (1.0%-7.3 %). Experimental results show that the coated fiber exhibits good resistance to matrix interference (2.5%-16.7 %) in complex biological matrices, and has been successfully used for OH-PAHs analysis in human urine and plasma. SIGNIFICANCE: FW technology realizes the transformation of the traditional powder form of COF in SPME coating to a uniform non-powder coating, giving its ability to exclude large molecules in complex biological matrices. A method for quantitatively detecting OH-PAHs in real biological samples was also developed. Therefore, the filament winding preparation method for F-COF@polyILs coated fibers, along with fibrous COFs' morphology control, has substantial implications for efficiently extracting target compounds from complex matrices.


Assuntos
Microextração em Fase Sólida , Microextração em Fase Sólida/métodos , Estruturas Metalorgânicas/química , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Substâncias Macromoleculares/química , Limite de Detecção , Adsorção , Técnicas Eletroquímicas/métodos
14.
J Chromatogr A ; 1726: 464961, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38723491

RESUMO

The improvement of the stability and adsorption properties of materials on targets in sample pre-treatment has long been an objective. Extensive efforts have been made to achieve this goal. In this work, metal-organic framework Ni-MOF precursors were first synthesized by solvothermal method using polyvinylpyrrolidone (PVP) as an ideal templating agent, stabiliser and nanoparticle dispersant. After carbonization and acid washing, the nanoporous carbon microspheres material (Ni@C-acid) was obtained. Compared with the material without acid treatment (Ni@C), the specific surface area, pore volume, adsorption performance of Ni@C-acid were increased. Thanks to its excellent characteristics (high stability, abundant benzene rings), Ni@C-acid was used as fiber coatings in headspace solid-phase microextraction (HS-SPME) technology for extraction and preconcentration of polycyclic aromatic hydrocarbons (PAHs) prior to gas chromatography-flame ionization detector (GC-FID) analysis. The experimental parameters of extraction temperature, extraction time, agitation speed, desorption temperature, desorption time and sodium chloride (NaCl) concentration were studied. Under optimal experimental conditions, the wide linear range (0.01-30 ng mL-1), the good correlation coefficient (0.9916-0.9984), the low detection limit (0.003-0.011 ng mL-1), and the high enrichment factor (5273-13793) were obtained. The established method was successfully used for the detection of trace PAHs in actual tea infusions samples and satisfied recoveries ranging from 80.94-118.62 % were achieved. The present work provides a simple method for the preparation of highly stable and adsorbable porous carbon microsphere materials with potential applications in the extraction of environmental pollutants.


Assuntos
Carbono , Limite de Detecção , Estruturas Metalorgânicas , Microesferas , Hidrocarbonetos Policíclicos Aromáticos , Microextração em Fase Sólida , Chá , Microextração em Fase Sólida/métodos , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Hidrocarbonetos Policíclicos Aromáticos/análise , Chá/química , Carbono/química , Estruturas Metalorgânicas/química , Porosidade , Adsorção , Níquel/química , Níquel/isolamento & purificação , Cromatografia Gasosa/métodos , Reprodutibilidade dos Testes
15.
J Chromatogr A ; 1722: 464889, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38598894

RESUMO

In this paper, three imidazole- and C18- bifunctional silica stationary phases (Sil-Im-C18) were prepared by adjusting introduction interval of octadecyltrichlorosilane (ODS) and 3-imidazol-1-ylpropyl(trimethoxy)silane (TMPImS), which can be used for reversed-phase liquid chromatography (RPLC) and ion exchange chromatography (IEC) with adjustable performance. The successful preparation of Sil-Im-C18 were confirmed by the characterizations of elemental analysis, infrared spectroscopy (FTIR) and contact angle (CA). Chromatographic performance of Sil-Im-C18 were evaluated by the separation of Tanaka test mixture, alkylbenzenes, linear PAHs and a set of analytes with different properties (uracil, phenol, 1,2-dinitrobenzene and naphthalene), and compared with commonly used C18 column. It was found that the chromatographic performance of Sil-Im-C18 changed significantly with the difference in bonding amount of imidazole and C18. Sil-Im-C18 demonstrated the excellent separation performance towards polycyclic aromatic hydrocarbons (PAHs), phenylesters, phenylamines, phenols and inorganic anions, and notably, nucleobases and nucleosides can be separated using pure water as mobile phases. The van Deemter plot showed that the column efficiency of Sil-Im-C18-3 was 64,933 plate·m-1 for naphthalene, indicated that Sil-Im-C18 was reasonably chromatographic columns. The RSD values of retention time were 0.22 %-0.61 % for 10 needles alkylbenzenes injected continuously at 50 °C to investigate thermal stability and repeatability, all the fluctuations of k of naphthalene were less than 2.3 % for Sil-Im-C18-1 during flushing 24 h with the mobile phase at different pH values (pH = 3 and 8), the retention time of alkylbenzenes were almost same for Sil-Im-C18-1 at different time, the RSD values of retention time of alkylbenzenes were 0.45 %-2.28 % for two batches Sil-Im-C18-1, revealing the excellent repeatability, thermal stability, durability and reproducibility of Sil-Im-C18, and implying a commercial prospect.


Assuntos
Cromatografia de Fase Reversa , Imidazóis , Hidrocarbonetos Policíclicos Aromáticos , Dióxido de Silício , Imidazóis/química , Dióxido de Silício/química , Cromatografia de Fase Reversa/métodos , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Hidrocarbonetos Policíclicos Aromáticos/química , Silanos/química , Cromatografia por Troca Iônica/métodos
16.
Artigo em Inglês | MEDLINE | ID: mdl-34871918

RESUMO

A method was developed for the simultaneous determination of polycyclic aromatic hydrocarbons (PAHs) and their hydroxylated metabolites (OH-PAHs) in human fingernails using liquid-liquid extraction and online purification. After surface decontamination by rinsing with acetone, the fingernails were digested with sodium hydroxide and subjected to liquid-liquid extraction with a mixture of n-hexane and methyl tertbutyl ether. The organic extract was then fractionated using a silica-based solid-phase extraction (SPE) cartridge to obtain a PAH fraction eluted with n-hexane/dichloromethane (v/v, 95:5) and an OH-PAH fraction eluted with dichloromethane/ethyl acetate (v/v, 50:50). The PAH fraction was directly injected into an online gel permeation chromatography-gas chromatography-triple quadrupole tandem mass spectrometry (GPC-GC-MS/MS) system, enabling rapid determination of 16 PAHs. A parallel online SPE liquid chromatography tandem mass spectrometry (LC-MS/MS) method was used to determine 12 OH-PAHs. Validation experiments showed that the recovery of PAH and OH-PAH were within range of 67.4%-105.1% (RSD ≤ 10.1%) and 72.8%-102.3% (RSD ≤ 10.9%), respectively, with limits of quantitation (LOQ) of 0.06-0.8 ng/g and 0.15-3.1 ng/g, respectively. Forty-two human fingernail samples from residents of Southern China were analyzed to establish background PAH and OH-PAH levels in this region. Several PAHs and OH-PAHs were detected, at concentrations of 97.5 to 3,687 ng/g for PAHs and 24.2 to 767 ng/g for OH-PAHs. The dominant homologues were two- and three-ring PAH isomers, notably naphthalene (Nap), fluorene (Flu), and phenanthrene (Phe), as well as the corresponding hydroxylated metabolites 2-OH-Nap, OH-Flu, and OH-Phe. Smoking, consuming barbecued food, and age had no significant effects on PAH exposure, but a larger sample would be required to confirm this finding. The online purification strategy presented here expedites cleanup and purification during analysis of human fingernails and should facilitate non-invasive biomonitoring of PAHs in humans, particularly when analyzing large numbers of samples.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Extração Líquido-Líquido/métodos , Unhas/química , Hidrocarbonetos Policíclicos Aromáticos , Espectrometria de Massas em Tandem/métodos , Feminino , Humanos , Limite de Detecção , Modelos Lineares , Masculino , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/química , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Reprodutibilidade dos Testes , Extração em Fase Sólida
17.
Pan Afr Med J ; 40: 45, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34795826

RESUMO

INTRODUCTION: neffa, a form of air-dried smokeless tobacco used in North Africa, is spuriously perceived as a lower risk alternative to smoking. The objective of this study was to provide information on some harmful constituents of neffa and to use them for cancer risk assessment. METHODS: a high-performance liquid chromatography method coupled with fluorescence detector was used to determine polycyclic aromatic hydrocarbons (PAHs) in one sample of neffa. An atomic absorption spectrometry was performed to determine the concentrations of lead and cadmium in three samples of neffa. The levels of toxicants found in neffa were used to assess for lifetime cancer risk as advocated by the US Environment Protection Agency. RESULTS: the determination of PAHs in neffa allowed the identification of phenanthrene and anthracene. However, the higher molecular weight PAHs such as Benzo(a)Pyrene B(a)P were not detected. The concentrations of cadmium and lead varied between 1.3 to 2.8µg/g and 1.7 to 4.6µg/g respectively. Cancer risk for cadmium and lead varied between 4.2E-03 to 9.3E-03 and 2.5E-06 to 6.4E-06 respectively. Cancer risk for Cd exceeded the range of 10E-04 to 10E-06 of an acceptable risk. CONCLUSION: neffa is not a healthy alternative for overcoming smoking addiction. It contains mineral and organic pulmonary toxicants. This study could serve as a scientific basis to inform consumers about the products´ toxicity and help them to quit smokeless tobacco (SLT) use.


Assuntos
Neoplasias/etiologia , Hidrocarbonetos Policíclicos Aromáticos/análise , Tabaco sem Fumaça/análise , Cádmio/análise , Carcinógenos/análise , Carcinógenos/isolamento & purificação , Cromatografia Líquida de Alta Pressão , Humanos , Chumbo/análise , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Medição de Risco , Espectrofotometria Atômica , Uso de Tabaco/efeitos adversos , Tabaco sem Fumaça/efeitos adversos , Tunísia
18.
J Sep Sci ; 44(24): 4313-4326, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34661968

RESUMO

To simultaneously and efficiently extract pollutants with differential polarities, we herein fabricated and characterized a multifunctional nanocomposite. The novel nanohybrids used NiFe2 O4 as magnetic cores, and NH2 -MIL-101(Al), ß-cyclodextrin and graphene oxide as functional components combined with magnetic cores. With the aid of graphene oxide's large π-conjugated system, NH2 -MIL-101(Al)'s strong adsorption to moderately/strongly polar chemicals, and ß-cyclodextrin's specific recognition effect, the nanohybrids realized synergistically efficient extraction of polyaromatic hydrocarbons and bisphenols with a logKow range of 3-6. Combined with acidic and alkaline sources, the nanohybrids-based effervescent tablets were prepared. Based on effervescent reaction-enhanced nanohybrids-based efficient adsorption/extraction and high performance liquid chromatography and fluorescence detection, we successfully developed an excellent microextraction method for the simultaneous determination of both polyaromatic hydrocarbons and bisphenols in roasted meat samples. Several important variables were optimized as follows: Na2 CO3 and tartaric acid as acidic and alkaline sources, 900 µLof the mixed solvent (acetone and hexane at 2:1 by v/v) as the eluent, 5 min of elution time. Under optimized conditions, the novel method gave low limits of detection (0.07-0.30 µg kg-1 ), satisfactory recoveries (86.9-103.9%), and high precision (relative standard deviations of 1.9-6.7%) in roasted lamb, beef, pork, chicken, and sausage samples.


Assuntos
Contaminação de Alimentos/análise , Magnetismo , Produtos da Carne/análise , Nanoestruturas , Compostos Orgânicos/isolamento & purificação , Microextração em Fase Sólida/métodos , Compostos Benzidrílicos/isolamento & purificação , Cromatografia Líquida de Alta Pressão/métodos , Limite de Detecção , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão , Fenóis/isolamento & purificação , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Espectrometria de Fluorescência/métodos
19.
Anal Bioanal Chem ; 413(27): 6823-6835, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34494123

RESUMO

A new gas chromatography-tandem mass spectrometry method for the determination of mono- and dihydroxylated polycyclic aromatic hydrocarbon metabolites (OH-PAHs and diol-PAHs) in urine was developed and validated. Various sample preparation procedures were compared, namely liquid-liquid extraction (LLE), dispersive solid-phase extraction (dSPE), and SPE, alone or combined. A novel two-stage derivatization approach using 2 silylation reagents was developed, and an experimental procedure design was used to optimize the programmed temperature vaporization-solvent vent injection (PTV-SV) GC parameters. The method focused on 11 target compounds resulting from four- to five-ring suspected carcinogenic PAHs. SPE was identified as an acceptable and more convenient extraction method for all tested metabolites, with extraction rates ranging from 63 to 86% and relative standard deviations lower than 20%. The two-stage derivatization approach successfully allowed first the derivatization of OH-PAHs by MTBSTFA (N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide) and then diol-PAHs by BSTFA (N,O-bis(trimethylsilyl)trifluoroacetamide) in a single run. The limits of quantification were in the range of 0.01-0.02 µg l-1 for OH-PAHs and 0.02-0.2 µg l-1 for diol-PAHs. The intra- and interday precisions were lower than 10%. The method was applied to determine PAH metabolites in urine collected at the beginning and at the end of the working week from 6 workers involved in aluminum production. The mean diol-PAH levels at the end of the week were 10 to 20 times higher (0.86-2.34 µg g-1 creatinine) than those of OH-PAHs (0.03-0.30 µg g-1). These results confirmed the usefulness of this new analytical technique for detecting and characterizing metabolic patterns of PAHs in urine and assessing carcinogenic occupational exposures.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Exposição Ocupacional/análise , Hidrocarbonetos Policíclicos Aromáticos/urina , Extração em Fase Sólida/métodos , Alumínio , Calibragem , Poluentes Ambientais/análise , Humanos , Hidroxilação , Extração Líquido-Líquido/métodos , Metalurgia , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Hidrocarbonetos Policíclicos Aromáticos/metabolismo , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
20.
J Sep Sci ; 44(21): 4037-4047, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34459084

RESUMO

A green, simple, and efficient dispersive micro-solid phase extraction method was developed for the extraction of polycyclic aromatic hydrocarbons from honey samples. In this method, for the first time, curcumin was used as an efficient and green sorbent to extract the analytes from the sample. After that the adsorbed analytes were eluted using a deep eutectic solvent prepared by mixing tetrabutylammonium chloride: ethylene glycol and analyzed by gas chromatography-mass spectrometry. Important experimental factors affecting adsorption and desorption steps of the method were optimized and under optimal experimental conditions, low limits of detection (0.14-0.37 ng/g) and quantification (0.49-1.3 ng/g), wide linear range (1.3-500 ng/g) with a coefficient of determination ≥0.994 were obtained. Relative standard deviation values for intra- and interday precisions were ≤7.5% for all of the analytes at a concentration of 2 ng/g for each analyte (n = 6). Extraction recovery of the method was in the range of 72-81%. Finally, 20 honey samples were analyzed and the analytes were successfully detected. The method is environment friendly because of the use of curcumin as a sorbent. Also, biodegradability of the used deep eutectic solvent components is another advantage of the method.


Assuntos
Curcumina/química , Solventes Eutéticos Profundos/química , Mel/análise , Hidrocarbonetos Policíclicos Aromáticos , Microextração em Fase Sólida/métodos , Adsorção , Cromatografia Gasosa-Espectrometria de Massas/métodos , Química Verde , Limite de Detecção , Modelos Lineares , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/química , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...