Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.352
Filtrar
1.
BMC Vet Res ; 20(1): 319, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39014383

RESUMO

BACKGROUND: Monitoring blood oxygenation is essential in immobilised rhinoceros, which are susceptible to opioid-induced hypoxaemia. This study assessed the reliability, clinical performance and trending ability of the Nonin PalmSAT 2500 A pulse oximeter's and the Masimo Radical-7 pulse co-oximeter's dual-wavelength technology, with their probes placed at two measurement sites, the inner surface of the third-eyelid and the scarified ear pinna of immobilised white rhinoceroses. Eight white rhinoceros were immobilised with etorphine-based drug combinations and given butorphanol after 12 min, and oxygen after 40 min, of recumbency. The Nonin and Masimo devices, with dual-wavelength probes attached to the third-eyelid and ear recorded arterial peripheral oxygen-haemoglobin saturation (SpO2) at pre-determined time points, concurrently with measurements of arterial oxygen-haemoglobin saturation (SaO2), from drawn blood samples, by a benchtop AVOXimeter 4000 co-oximeter (reference method). Reliability of the Nonin and Masimo devices was evaluated using the Bland-Altman and the area root mean squares (ARMS) methods. Clinical performance of the devices was evaluated for their ability to accurately detect clinical hypoxemia using receiver operating characteristic (ROC) curves and measures of sensitivity, specificity, and positive and negative predictive values. Trending ability of the devices was assessed by calculating concordance rates from four-quadrant plots. RESULTS: Only the Nonin device with transflectance probe attached to the third-eyelid provided reliable SpO2 measurements across the 70 to 100% saturation range (bias - 1%, precision 4%, ARMS 4%). Nonin and Masimo devices with transflectance probes attached to the third-eyelid both had high clinical performance at detecting clinical hypoxaemia [area under the ROC curves (AUC): 0.93 and 0.90, respectively]. However, the Nonin and Masimo devices with transmission probes attached to the ear were unreliable and provided only moderate clinical performance. Both Nonin and Masimo devices, at both measurement sites, had concordance rates lower than the recommended threshold of ≥ 90%, indicating poor trending ability. CONCLUSIONS: The overall assessment of reliability, clinical performance and trending ability indicate that the Nonin device with transflectance probe attached to the third-eyelid is best suited for monitoring of blood oxygenation in immobilised rhinoceros. The immobilisation procedure may have affected cardiovascular function to an extent that it limited the devices' performance.


Assuntos
Oximetria , Oxigênio , Perissodáctilos , Animais , Perissodáctilos/sangue , Oximetria/veterinária , Oximetria/instrumentação , Oximetria/métodos , Reprodutibilidade dos Testes , Oxigênio/sangue , Masculino , Imobilização/veterinária , Imobilização/instrumentação , Imobilização/métodos , Feminino
2.
BMC Musculoskelet Disord ; 25(1): 469, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38879465

RESUMO

PURPOSE: The aim of this study was to compare the clinical outcomes between patients with chronic ankle instability (CAI) undergoing arthroscopic anterior talofibular ligament (ATFL) repair who received elastic bandage treatment and those who received lower-leg cast immobilization. METHODS: CAI patients with isolated ATFL injury undergoing arthroscopic ATFL repair from January 2017 and August 2019 were included in the study. The visual analogue scale (VAS) at rest and during activities, American Orthopedic Foot and Ankle Society (AOFAS) score, Karlsson Ankle Functional Score (Karlsson score), and time of returning to walk, walk normally, work and sports were evaluated preoperatively, and at 6 months and 12 months follow-up. RESULTS: A total of 41 patients were included in this study. Among them, 24 patients accepted lower-leg cast fixation, and the other 17 patients were immobilized with elastic bandage. Compared to patients with lower-leg immobilization, patients with elastic bandage fixation had significantly lower VAS during activities (P = 0.021) and higher AOFAS score (P = 0.015) at 12 months follow-up. The Karlsson score at 6 months follow-up were significantly higher in elastic bandage group than those in lower-leg group (P = 0.011). However, no significant difference was observed in time of returning to walk, work and sports between the two groups. CONCLUSION: Elastic bandage treatment was better than lower-leg cast immobilization in terms of eliminating pain symptom at 12 months follow-up, and improving ankle functional outcome at 6 months follow-up. Moreover, the present study emphasized that lower-leg cast immobilization offered no advantages in arthroscopic ATFL repair postoperative immobilization. STUDY DESIGN: Cohort study; Level of evidence, 3.


Assuntos
Moldes Cirúrgicos , Instabilidade Articular , Ligamentos Laterais do Tornozelo , Humanos , Feminino , Masculino , Adulto , Ligamentos Laterais do Tornozelo/cirurgia , Ligamentos Laterais do Tornozelo/lesões , Resultado do Tratamento , Instabilidade Articular/cirurgia , Adulto Jovem , Articulação do Tornozelo/cirurgia , Articulação do Tornozelo/fisiopatologia , Artroscopia/métodos , Estudos Retrospectivos , Traumatismos do Tornozelo/cirurgia , Traumatismos do Tornozelo/terapia , Imobilização/métodos , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Seguimentos
3.
Sci Rep ; 14(1): 13460, 2024 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-38862648

RESUMO

In conservative treatment for proximal humerus fractures (PHFs), the immobilization position of the affected arm should not be determined uniformly. The aim of this study is to investigate the optimal immobilization position for conservative treatment of different types of PHFs. We hypothesized that the optimal position minimizing the deforming force in PHFs depends on the fracture components involved. PHF models involving either the surgical neck (SN) or greater tuberosity (GT) were created using 12 fresh-frozen cadaveric shoulders. In the SN model, the deforming forces on the pectoralis major muscle were measured in full adduction by increasing external rotation. In the GT model, the deforming force of the supraspinatus muscle was measured in neutral rotation by decreasing abduction, and the deforming force of the infraspinatus muscle was measured in full adduction by increasing internal rotation, respectively. In the SN model, the deforming force of the pectoralis major muscle increased significantly with external rotation from full internal rotation to neutral rotation (P = 0.006), indicating that the arm should be placed in full internal rotation. In the GT model, the deforming force of the supraspinatus muscle increased significantly with adduction from 45° of abduction to full adduction (P = 0.006); the deforming force of the infraspinatus muscle increased significantly with internal rotation from neutral rotation to full internal rotation (P = 0.006). These findings should be considered when placing the arm in abduction and neutral rotation so as to minimize the deforming force by either the supra or infraspinatus muscle. In conservative treatment for PHFs, the affected arm should be placed in a position that minimizes the deforming force on the fracture components involved.


Assuntos
Cadáver , Tratamento Conservador , Fraturas do Ombro , Humanos , Fraturas do Ombro/terapia , Fenômenos Biomecânicos , Idoso , Masculino , Feminino , Tratamento Conservador/métodos , Idoso de 80 Anos ou mais , Imobilização/métodos , Pessoa de Meia-Idade , Amplitude de Movimento Articular
4.
Cancer Radiother ; 28(3): 229-235, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38871604

RESUMO

PURPOSE: The main objective of this study was to assess inter- and intrafraction errors for two patient immobilisation devices in the context of lung stereotactic body radiation therapy: a vacuum cushion and a simple arm support. MATERIALS AND METHODS: Twenty patients who were treated with lung stereotactic body radiation therapy in supine position with arms above their head were included in the study. Ten patients were setup in a vacuum cushion (Bluebag™, Elekta) and ten other patients with a simple arm support (Posirest™, Civco). A pretreatment four-dimensional cone-beam computed tomography and a post-treatment three-dimensional cone-beam computed tomography were acquired to compare positioning and immobilisation accuracy. Based on a rigid registration with the planning computed tomography on the spine at the target level, translational and rotational errors were reported. RESULTS: The median number of fractions per treatment was 5 (range: 3-10). Mean interfraction errors based on 112 four-dimensional cone-beam computed tomographies were similar for both setups with deviations less than or equal to 1.3mm in lateral and vertical direction and 1.2° in roll and yaw. For longitudinal translational errors, mean interfraction errors were 0.7mm with vacuum cushion and -3.9mm with arm support. Based on 111 three-dimensional cone-beam computed tomographies, mean lateral, longitudinal and vertical intrafraction errors were -0.1mm, -0.2mm and 0.0mm respectively (SD: 1.0, 1.2 and 1.0mm respectively) for the patients setup with vacuum cushion, and mean vertical, longitudinal and lateral intrafraction errors were -0.3mm, -0.7mm and 0.1mm respectively (SD: 2.3, 1.8 and 1.4mm respectively) for the patients setup with arm support. Intrafraction errors means were not statistically different between both positions but standard deviations were statistically larger with arm support. CONCLUSION: The results of our study showed similar inter and intrafraction mean deviations between both positioning but a large variability in intrafraction observed with arm support suggested a more accurate immobilization with vacuum cushion.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Imobilização , Neoplasias Pulmonares , Posicionamento do Paciente , Radiocirurgia , Humanos , Radiocirurgia/métodos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Imobilização/métodos , Imobilização/instrumentação , Estudos Prospectivos , Idoso , Feminino , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada de Feixe Cônico/métodos , Idoso de 80 Anos ou mais , Erros de Configuração em Radioterapia/prevenção & controle , Fracionamento da Dose de Radiação , Decúbito Dorsal , Tomografia Computadorizada Quadridimensional/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Vácuo
5.
Bone Joint J ; 106-B(6): 623-630, 2024 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-38821496

RESUMO

Aims: The aim of this trial was to assess the cost-effectiveness of a soft bandage and immediate discharge, compared with rigid immobilization, in children aged four to 15 years with a torus fracture of the distal radius. Methods: A within-trial economic evaluation was conducted from the UK NHS and personal social services (PSS) perspective, as well as a broader societal point of view. Health resources and quality of life (the youth version of the EuroQol five-dimension questionnaire (EQ-5D-Y)) data were collected, as part of the Forearm Recovery in Children Evaluation (FORCE) multicentre randomized controlled trial over a six-week period, using trial case report forms and patient-completed questionnaires. Costs and health gains (quality-adjusted life years (QALYs)) were estimated for the two trial treatment groups. Regression was used to estimate the probability of the new treatment being cost-effective at a range of 'willingness-to-pay' thresholds, which reflect a range of costs per QALY at which governments are typically prepared to reimburse for treatment. Results: The offer of a soft bandage significantly reduced cost per patient (saving £12.55 (95% confidence interval (CI) -£5.30 to £19.80)) while QALYs were similar (QALY difference between groups: 0.0013 (95% CI -0.0004 to 0.003)). The high probability (95%) that offering a bandage is a cost-effective option was consistent when examining the data in a range of sensitivity analyses. Conclusion: In addition to the known clinical equivalence, this study found that the offer of a bandage reduced cost compared with rigid immobilization among children with a torus fracture of the distal radius. While the cost saving was small for each patient, the high frequency of these injuries indicates a significant saving across the healthcare system.


Assuntos
Análise Custo-Benefício , Alta do Paciente , Fraturas do Rádio , Humanos , Criança , Fraturas do Rádio/terapia , Fraturas do Rádio/economia , Adolescente , Feminino , Masculino , Pré-Escolar , Bandagens/economia , Anos de Vida Ajustados por Qualidade de Vida , Reino Unido , Imobilização/métodos , Fixação de Fratura/economia , Fixação de Fratura/métodos , Qualidade de Vida , Análise de Custo-Efetividade
6.
Ann R Coll Surg Engl ; 106(6): 478-484, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38787306

RESUMO

INTRODUCTION: Climate change is estimated to be the biggest global health threat of the 21st century, and has prompted calls to move away from processes in healthcare associated with high energy consumption and greenhouse gas emission. In musculoskeletal medicine, splints are widely used for limb immobilisation. These have typically been made from single-use materials such as gypsum, although in recent years purportedly environmentally friendly splints have been designed. In this systematic review, we set out to assess the clinical effectiveness of all commercially available environmentally friendly splinting materials, including Woodcast®. METHODS: The AMED (Allied and Complementary Medicine Database), CINAHL® (Cumulative Index to Nursing and Allied Health Literature), Cochrane Central Register of Controlled Trials, Embase®, Emcare® and MEDLINE® databases were searched to identify studies assessing the clinical effectiveness of biodegradable and environmentally friendly splints prior to paper review and data extraction. Formal quantitative synthesis was not possible owing to the substantial heterogeneity in the study designs and outcome measures. RESULTS: Six papers met the inclusion criteria, all investigating one particular splint material (Woodcast®). One was a case series, two were cohort studies and three were randomised controlled trials. Primary outcome measures were heterogeneous but the environmentally friendly splints were generally equivalent to traditional splint materials. Studies were mostly at a high risk of bias. CONCLUSIONS: There is limited research assessing 'green' splints in practice although the data suggest similarity with existing materials and no substantial safety concerns. Further scrutiny of the clinical effectiveness and environmental credentials of such splints is also required.


Assuntos
Contenções , Humanos , Imobilização/instrumentação , Imobilização/métodos
9.
J Orthop Surg Res ; 19(1): 282, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38711065

RESUMO

BACKGROUND: The aim of this study was to compare the effects of four different immobilization methods [single sugar tong splint (SSTS), double sugar tong splint (DSTS), short arm cast (SAC), and long arm cast (LAC)] commonly used for restricting forearm rotation in the upper extremity. METHODS: Forty healthy volunteers were included in the study. Dominant extremities were used for measurements. Basal pronation and supination of the forearm were measured with a custom-made goniometer, and the total rotation arc was calculated without any immobilization. Next, the measurements were repeated with the SAC, LAC, SSTS and DSTS. Each measurement was compared to the baseline value, and the percentage of rotation restriction was calculated. RESULTS: The most superior restriction rates were observed for the LAC (p = 0.00). No statistically significant difference was detected between the SSTS and DSTS in terms of the restriction of supination, pronation or the rotation arc (p values, 1.00, 0.18, and 0.50, respectively). Statistically significant differences were not detected between the SAC and the SSTS in any of the three parameters (p values, 0.25; 1.00; 1.00, respectively). When the SAC and DSTS were compared, while there was no significant difference between the two methods in pronation (p = 0.50), a statistically significant difference was detected in supination (p = 0.01) and in the total rotation arc (p = 0.03). CONCLUSION: The LAC provides superior results in restricting forearm rotation. The SAC and SSTS had similar effects on forearm rotation. The DSTS, which contains, in addition to the SSTS, a sugar tong portion above the elbow, does not provide additional rotational stability.


Assuntos
Antebraço , Imobilização , Contenções , Humanos , Masculino , Feminino , Adulto , Rotação , Antebraço/fisiologia , Adulto Jovem , Imobilização/métodos , Supinação/fisiologia , Pronação/fisiologia , Moldes Cirúrgicos , Voluntários Saudáveis , Amplitude de Movimento Articular/fisiologia
10.
Eur J Orthop Surg Traumatol ; 34(5): 2457-2464, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38796813

RESUMO

PURPOSE: Ankle fracture-dislocations (AFD) often necessitate staged management involving temporary external fixation (EF) due to mechanical instability or blistering. However, limited literature exists on the optimal temporary immobilization method for low-energy closed AFD. This study compared baseline patient and fracture characteristics, along with clinical and radiological outcomes between AFD initially immobilized with EF versus splinting. METHODS: A retrospective cohort study was conducted involving patients with AFD temporarily immobilized using EF or splinting, followed by definitive open reduction and internal fixation. Quality of reduction (QOR) was assessed for each patient post-initial immobilization and after the definitive surgery. RESULTS: The study encompassed 194 patients: 138 treated with a splint (71.1%) and 56 (28.9%) with EF. Secondary loss of reduction had occurred in three patients who were splinted (2.2%). The mean ages in the EF and splint groups were 63.2 and 56.1 years, respectively (p = 0.01). Posterior malleolus fracture (PMF) and blisters were more prevalent in EF patients (69.6% vs. 43.5% for PMF and 76.8% vs. 20.3% for blisters, respectively; p = 0.05 and p < 0.01). Postoperative complication rates were 8.9% for EF versus 10.9% for splinting (p = 0.69). Satisfactory final QOR was attained in 79.8% of patients treated with a splint versus 64.3% with EF (p = 0.02). CONCLUSION: Patients immobilized by EF presented with poorer baseline characteristics and had more unstable injuries. Nevertheless, postoperative complication rates were comparable. Thus, EF appears to be a valuable tool for standardizing outcomes in AFD patients with a less favorable prognosis.


Assuntos
Fraturas do Tornozelo , Fratura-Luxação , Imobilização , Contenções , Humanos , Estudos Retrospectivos , Masculino , Fraturas do Tornozelo/cirurgia , Feminino , Pessoa de Meia-Idade , Fratura-Luxação/cirurgia , Fratura-Luxação/diagnóstico por imagem , Imobilização/métodos , Fixação Interna de Fraturas/métodos , Idoso , Redução Aberta/métodos , Adulto , Resultado do Tratamento , Fixadores Externos
11.
Radiother Oncol ; 196: 110314, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38677329

RESUMO

PURPOSE: To compare patient discomfort and immobilisation performance of open-face and closed immobilization masks in cranial radiotherapy. MATERIAL AND METHODS: This was a single-center randomized self-controlled clinical trial. At CT simulation, an open-face and closed mask was made for each patient and treatment plans with identical dose prescription were generated for each mask. Patients were randomised to start treatment with an open-face or closed mask. Masks were switched halfway through the treatment course; every patient was their own control. Patients self-reported discomfort, anxiety and pain using the visual analogue scale (VAS). Inter- and intrafraction set-up variability was measured with planar kV imaging and a surface guided radiotherapy (SGRT) system for the open-face masks. RESULTS: 30 patients with primary or metastatic brain tumors were randomized - 29 completed radiotherapy to a median total dose of 54 Gy (range 30-60 Gy). Mean discomfort VAS score was significantly lower with open-face masks (0.5, standard deviation 1.0) vs. closed masks (3.3, standard deviation 2.9), P < 0.0001. Anxiety and pain VAS scores were significantly lower with open-face masks (P < 0.0001). Closed masks caused more discomfort in infraorbital (P < 0.001) and maxillary (P = 0.02) areas. Two patients and 27 patients preferred closed or open-face masks, respectively. Interfraction longitudinal shifts and roll and yaw rotations were significantly smaller and lateral shifts were significantly larger with closed masks in combination with the laser system (P < 0.05) compared to open masks in combination with a SGRT system. Intrafraction variability did not differ between the masks. CONCLUSIONS: Open-face masks are associated with decreased patient discomfort without compromising patient positioning and immobilisation accuracy.


Assuntos
Neoplasias Encefálicas , Fracionamento da Dose de Radiação , Imobilização , Máscaras , Humanos , Masculino , Feminino , Imobilização/instrumentação , Imobilização/métodos , Pessoa de Meia-Idade , Idoso , Neoplasias Encefálicas/radioterapia , Adulto , Irradiação Craniana/efeitos adversos , Irradiação Craniana/métodos
12.
Exp Physiol ; 109(7): 1145-1162, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38687158

RESUMO

Limb immobilization causes rapid declines in muscle strength and mass. Given the role of the nervous system in immobilization-induced weakness, targeted interventions may be able to preserve muscle strength, but not mass, and vice versa. The purpose of this study was to assess the effects of two distinct interventions during 1 week of knee joint immobilization on muscle strength (isometric and concentric isokinetic peak torque), mass (bioimpedance spectroscopy and ultrasonography), and neuromuscular function (transcranial magnetic stimulation and interpolated twitch technique). Thirty-nine healthy, college-aged adults (21 males, 18 females) were randomized into one of four groups: immobilization only (n = 9), immobilization + action observation/mental imagery (AOMI) (n = 10), immobilization + neuromuscular electrical stimulation (NMES) (n = 12), or control group (n = 8). The AOMI group performed daily video observation and mental imagery of knee extensions. The NMES group performed twice daily stimulation of the quadriceps femoris. Based on observed effect sizes, it appears that AOMI shows promise as a means of preserving voluntary strength, which may be modulated by neural adaptations. Strength increased from PRE to POST in the AOMI group, with +7.2% (Cohen's d = 1.018) increase in concentric isokinetic peak torque at 30°/s. However, NMES did not preserve muscle mass. Though preliminary, our findings highlight the specific nature of clinical interventions and suggest that muscle strength can be independently targeted during rehabilitation. This study was prospectively registered: ClinicalTrials.gov NCT05072652.


Assuntos
Articulação do Joelho , Força Muscular , Humanos , Masculino , Feminino , Adulto Jovem , Força Muscular/fisiologia , Articulação do Joelho/fisiologia , Adulto , Imobilização/métodos , Estimulação Elétrica/métodos , Torque , Músculo Esquelético/fisiologia , Músculo Quadríceps/fisiologia , Imaginação/fisiologia , Joelho/fisiologia , Estimulação Magnética Transcraniana/métodos
13.
Radiography (Lond) ; 30(3): 840-842, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38574580

RESUMO

INTRODUCTION: Magnetic Resonance-guided Focused Ultrasound (MRgFUS) treatment for certain anatomy locations can be extremely challenging due to patient positioning and potential motion. This present study describes the treatment of a recurrent tenosynovial giant cell tumor of the plantar forefoot using the ExAblate 2100 system in combination with patient immobilization device. METHODS: Prior to the treatment, several patient immobilization devices were investigated. Vacuum cushions were selected and tested for safety and compatibility with the treatment task and the MR environment. RESULTS: During the treatment, one vacuum cushion immobilized the patient's right leg in knee flexion and allowed the bottom of the foot to be securely positioned on the treatment window. Another vacuum cushion supported the patient upper body extended outside the scanner bore. 19 sonications were successfully executed. The treatment was judged to be successful. No immediate complications were observed. CONCLUSIONS: MRgFUS treatment of a recurrent tenosynovial giant cell tumor of the right plantar forefoot was successful with the use of patient immobilization vacuum cushions. IMPLICATIONS FOR PRACTICE: The immobilization system could be utilized to aid future MRgFUS treatment of lesions in challenging anatomic locations. Various sizes of the vacuum cushions are available to potentially better accommodate other body parts and treatment configurations.


Assuntos
Tumor de Células Gigantes de Bainha Tendinosa , Imobilização , Recidiva Local de Neoplasia , Humanos , Tumor de Células Gigantes de Bainha Tendinosa/diagnóstico por imagem , Tumor de Células Gigantes de Bainha Tendinosa/cirurgia , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Imobilização/instrumentação , Imobilização/métodos , Imageamento por Ressonância Magnética/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem
14.
Vet Radiol Ultrasound ; 65(4): 323-333, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38554033

RESUMO

In veterinary radiotherapy, highly reproducible immobilization is important for accurate irradiation. Consequently, we developed a new reusable head-immobilization method for dogs using cylinders. This study aimed to compare the accuracy of our novel immobilization method using cylinders with that of bite-block type immobilization methods. Three immobilization methods were compared: bite-block only, bite-block combined with torso immobilization, and immobilization using cylinders. Five beagles with canine teeth underwent CT five times for each of the three immobilization methods. One beagle without canine teeth underwent CT 15 times using each method. Three maxillary landmarks (maxillary incisor, frontal sinus, and occipital bone) and one mandibular landmark (mandibular incisor) were established, and the errors in each immobilization method were measured. For all head landmarks, the error in the immobilization method using cylinders was the most reproducible, with the smallest errors. No significant differences were observed in the time required for immobilization. Although there were limitations (such as the use of dogs from a single breed, a single episode of anesthesia, no disassembly of the immobilization system between scans, and the same person performing the positioning on the same day), we found our new reusable immobilization method using cylinders was the most accurate among the three compared methods. This was a proof-of-principle study to evaluate head immobilization using cylinders, and further investigations are needed to confirm its clinical utility.


Assuntos
Imobilização , Tomografia Computadorizada por Raios X , Animais , Cães , Imobilização/veterinária , Imobilização/instrumentação , Imobilização/métodos , Tomografia Computadorizada por Raios X/veterinária , Doenças do Cão/radioterapia , Masculino , Feminino , Cabeça , Reprodutibilidade dos Testes
15.
J Zoo Wildl Med ; 55(1): 200-206, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38453503

RESUMO

The maned sloth (Bradypus torquatus) is an endemic and endangered species of two Brazilian states, with much unknown biological information needed to direct conservation actions. Other sloth species have been studied regarding anesthesia; however, there is a lack of anesthesia research for the maned sloth. Anesthetic data were collected from 12 free-range maned sloths that were immobilized for a field examination. Individuals were anesthetized using a combination of ketamine (4.0 mg/kg) and medetomidine (0.03 mg/kg), and antagonized with atipamezole (0.1 mg/kg). Time to induction and recovery were recorded and compared with sex and age classes. After the induction and until antagonist administration, physiological parameters (rectal temperature, heart rate, respiratory rate, and oxygen saturation) were recorded every 10 min during anesthesia and were statistically evaluated over time. Induction was fast (3.21 ± 0.76), but recovery was longer (113.3 ± 18) when compared to other studies. Induction and recovery times were not different across sex or age classes. Rectal temperature, heart rate, and oxygen saturation remained stable throughout the procedure. Respiratory rate significantly decreased over time, from 18.25 ± 7.03 to 13.17 ± 3.66 movements per minute. Our results indicate that the described combination of ketamine and medetomidine is a safe and effective choice for anesthesia of maned sloths.


Assuntos
Anestésicos , Ketamina , Bichos-Preguiça , Humanos , Animais , Medetomidina/farmacologia , Ketamina/farmacologia , Bichos-Preguiça/fisiologia , Animais Selvagens/fisiologia , Anestésicos/farmacologia , Imobilização/veterinária , Imobilização/métodos , Hipnóticos e Sedativos/farmacologia , Frequência Cardíaca , Anestésicos Dissociativos/farmacologia
16.
J Zoo Wildl Med ; 55(1): 207-211, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38453504

RESUMO

Sedation, recovery response, and physiologic outcomes were evaluated in five captive reindeer (Rangifer tarandus) in Minnesota using a completely reversible immobilization protocol. Reindeer were immobilized with butorphanol (0.23-0.32 mg/kg), midazolam (0.23-0.32 mg/kg), and medetomidine (0.15 mg/kg) (BMM) via IM dart. Induction time (IT), recumbency time (DT), and recovery time (RT) were recorded. Temperature (T), respiratory rate (RR), pulse rate (PR), pulse oximetry (SpO2), arterial blood gas values including oxygen (PaO2), and carbon dioxide (PaCO2) tensions and lactate (Lac) were recorded preoxygen supplementation and 15 min postoxygen supplementation. Reversal was done using naltrexone (2.3-3.0 mg/kg), flumazenil (0.008-0.01 mg/kg) and atipamezole (0.62-0.78 mg/kg) (NFA) IM, limiting recumbency to 1 h. Median IT, DT, and RT were 5 min, 46 min, and 7 min, respectively. SpO2 (92 to 99%, P = 0.125), PaO2 (45.5 to 97 mmHg, P = 0.25), and PaCO2 (46.5 to 54.6 mmHg, P = 0.25) all increased, whereas Lac (3.02 to 1.93 mmol/L, P = 0.25) decreased between baseline and 15 min postoxygen supplementation, without statistical significance. BMM immobilization, and reversal with NFA provided rapid and effective immobilization and recovery, respectively. Oxygen supplementation mitigated hypoxemia in all reindeer.


Assuntos
Ketamina , Rena , Animais , Medetomidina/farmacologia , Midazolam/farmacologia , Butorfanol/farmacologia , Hipnóticos e Sedativos/farmacologia , Ketamina/farmacologia , Oxigênio , Imobilização/veterinária , Imobilização/métodos , Frequência Cardíaca
17.
Am J Sports Med ; 52(2): 544-554, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-36867050

RESUMO

BACKGROUND: Arthroscopic stabilization has been established as a superior treatment option for primary glenohumeral instability when compared with immobilization in internal rotation. However, immobilization in external rotation (ER) has recently gained interest as a viable nonoperative treatment option for patients with shoulder instability. PURPOSE: To compare the rates of recurrent instability and subsequent surgery in patients undergoing treatment for primary anterior shoulder dislocation with arthroscopic stabilization versus immobilization in ER. STUDY DESIGN: Systematic review; Level of evidence, 2. METHODS: A systematic review was performed by searching PubMed, the Cochrane Library, and Embase to identify studies that'evaluated patients being treated for primary anterior glenohumeral dislocation with either arthroscopic stabilization or immobilization in ER. The search phrase used various combinations of the keywords/phrases "primary closed reduction,""anterior shoulder dislocation,""traumatic,""primary,""treatment,""management,""immobilization,""external rotation,""surgical,""operative,""nonoperative," and "conservative." Inclusion criteria included patients undergoing treatment for primary anterior glenohumeral joint dislocation with either immobilization in ER or arthroscopic stabilization. Rates of recurrent instability, subsequent stabilization surgery, return to sports, positive postintervention apprehension tests, and patient-reported outcomes were evaluated. RESULTS: The 30 studies that met inclusion criteria included 760 patients undergoing arthroscopic stabilization (mean age, 23.1 years; mean follow-up time, 55.1 months) and 409 patients undergoing immobilization in ER (mean age, 29.8 years; mean follow-up time, 28.8 months). Overall, 8.8% of operative patients experienced recurrent instability at latest follow-up compared with 21.3% of patients who had undergone ER immobilization (P < .0001). Similarly, 5.7% of operative patients had undergone a subsequent stabilization procedure at latest follow-up compared with 11.3% of patients who had undergone ER immobilization (P = .0015). A higher rate of return to sports was found in the operative group (P < .05), but no other differences were found between groups. CONCLUSION: Patients undergoing arthroscopic treatment for primary anterior glenohumeral dislocation with arthroscopic stabilization can be expected to experience significantly lower rates of recurrent instability and subsequent stabilization procedures compared with patients undergoing ER immobilization.


Assuntos
Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Esportes , Humanos , Adulto Jovem , Adulto , Luxação do Ombro/cirurgia , Luxação do Ombro/etiologia , Articulação do Ombro/cirurgia , Ombro , Instabilidade Articular/cirurgia , Instabilidade Articular/etiologia , Artroscopia , Recidiva , Imobilização/efeitos adversos , Imobilização/métodos
18.
J Wildl Dis ; 60(1): 188-192, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37909402

RESUMO

Immobilization kits including butorphanol-azaperone-medetomidine (BAM) and nalbuphine-azaperone-medetomidine can provide effective, safe, and easy-to-use protocols in bears. Nalbuphine-azaperone-medetomidine is not commercially available but may be useful for wildlife agencies because it does not contain controlled substances. This study directly compared BAM to nalbuphine-azaperone-medetomidine immobilization in 10 juvenile healthy black bears (10 mo old; four females, six males) undergoing prerelease examinations after rehabilitation. Bears were immobilized via remote delivery of 1 mL of BAM (n=5) or nalbuphine-azaperone-medetomidine (n=5) intramuscularly in the shoulder during December (randomized, blinded trial). Bears were intubated, monitored with an electrocardiogram, pulse oximeter, capnograph, noninvasive blood pressure cuff, and rectal thermometer, and underwent physical examination, sample collection, morphometrics, and ear-tag placement. Induction, physiologic, and recovery parameters were recorded, including arterial blood gas analysis. The anesthetic agents were antagonized with atipamezole and naltrexone. There were no differences between protocols in induction or recovery times. There were no differences between protocols in heart rate, respiratory rate, temperature, oxygen saturation, end-tidal CO2, mean arterial pressure, or blood gas analysis or any differences between male and female bears in any parameters. Bears were hypertensive and normoxemic with low oxygen saturation via pulse oximeter, but all recovered smoothly and were released within 2 h of recovery. This study supports that nalbuphine-azaperone-medetomidine is clini-cally as safe and effective as BAM in American black bears.


Assuntos
Nalbufina , Ursidae , Feminino , Masculino , Animais , Medetomidina/farmacologia , Azaperona/farmacologia , Butorfanol/farmacologia , Nalbufina/farmacologia , Hipnóticos e Sedativos/farmacologia , Oxigênio , Imobilização/veterinária , Imobilização/métodos
19.
J Wildl Dis ; 60(1): 95-104, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37924235

RESUMO

Raccoons (Procyon lotor) are frequently handled using chemical immobilization in North America for management and research. In a controlled environment, we compared three drug combinations: ketamine-xylazine (KX), butorphanol-azaperone-medetomidine (BAM), and nalbuphine-medetomidine-azaperone (NalMed-A) for raccoon immobilization. In crossover comparisons, raccoons received a mean of the following: 8.66 mg/kg ketamine and 1.74 mg/kg xylazine (0.104 mL/kg KX); 0.464 mg/kg butorphanol, 0.155 mg/kg azaperone, and 0.185 mg/kg medetomidine (0.017 mL/kg BAM); and 0.800 mg/kg nalbuphine, 0.200 mg/kg azaperone, and 0.200 mg/kg medetomidine (0.020 mL/kg NalMed-A). Induction time was shortest with KX (mean±SE, 10.0±0.7 min) and longest with NalMed-A (13.0±1.3 min). A sampling procedure was completed on 89% (16/18), 72% (13/18), and 89% (16/18) of the raccoons administered KX, BAM, and NalMed-A, respectively. Reasons for incomplete sampling included inadequate immobilization (one KX and one NalMed-A), responsive behaviors (one each with KX, BAM, NalMed-A), or animal safety (four BAM). Mean recovery time for KX was 32.8±7.1 min without antagonizing and 28.6±5.2 min following delivery of an antagonist. Mean recovery time was 6.2±0.8 min for BAM and 5.1±0.5 min for NalMed-A after antagonizing. Only with KX were raccoons observed to recover without use of an antagonist. Supplemental oxygen was provided to 23% (3/13), 72% (13/18), and 71% (12/17) of raccoons immobilized with KX, BAM, and NalMed-A, respectively. Hypoxemia at <80% oxygen saturation occurred in 0% (0/17), 27% (4/15), and 6% (1/16) of the raccoons administered KX, BAM, and NalMed-A, respectively; all raccoons fully recovered from chemical immobilization. All combinations could be used for raccoon immobilization; however, the need for delivery of supplemental oxygen to a majority of raccoons immobilized with BAM and NalMed-A may limit broader use of these agents for certain field studies involving capture, sample, and release of free-ranging animals from a practical standpoint.


Assuntos
Ketamina , Nalbufina , Animais , Medetomidina/farmacologia , Azaperona/farmacologia , Butorfanol/farmacologia , Guaxinins , Nalbufina/farmacologia , Xilazina/farmacologia , Hipnóticos e Sedativos/farmacologia , Ketamina/farmacologia , Imobilização/veterinária , Imobilização/métodos , Oxigênio
20.
Am J Emerg Med ; 76: 150-154, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38086180

RESUMO

INTRODUCTION: This review aims to evaluate current practices regarding spine immobilization in pediatric trauma patients to evaluate their efficacy, reliability, and impact on clinical outcomes to guide future research and improved evidence-based practice guidelines. METHODS: PubMed, ProQuest, Embase, Google Scholar, and Cochrane were queried for studies pertaining to spinal immobilization practices in pediatric trauma patients. Articles were separated into studies that explored both the efficacy and clinical outcomes of spine immobilization. Outcomes evaluated included frequency of spinal imaging, self-reported pain level, emergency department length of stay (ED-LOS), and ED disposition. RESULTS: Six articles were included, with two studies examining clinical outcomes and 4 studies evaluating the efficacy and reliability of immobilization techniques. Immobilized children were significantly more likely to undergo cervical spine imaging (OR 8.2, p < 0.001), be admitted to the floor (OR 4.0, p < 0.001), be taken to the ICU or OR (OR 5.3, p < 0.05) and reported a higher median pain score. Older children were significantly more likely to be immobilized. No immobilization techniques consistently achieved neutral positioning, and patients most often presented in a flexed position. Lapses in immobilization occurred in 71.4% of patients. CONCLUSION: Immobilized pediatric patients underwent more cervical radiographs, and had higher hospital and ICU admission rates, and higher mean pain scores than those without immobilization. Immobilization was inconsistent across age groups and often resulted in lapses and improper alignment. Further research is needed to identify the most appropriate immobilization techniques for pediatric patients and when to use them.


Assuntos
Traumatismos da Coluna Vertebral , Criança , Humanos , Adolescente , Reprodutibilidade dos Testes , Traumatismos da Coluna Vertebral/diagnóstico por imagem , Traumatismos da Coluna Vertebral/terapia , Traumatismos da Coluna Vertebral/etiologia , Vértebras Cervicais/lesões , Radiografia , Dor/etiologia , Imobilização/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...